CSM_E52_DS_E_16_1
1
Temperature Sensor
E52
A Wide Variety of High-precision
Temperature Sensors
New and improved E52 temperature sensor series.
Wide selection of sensors compatible with M3 screws
Ideal for the thermal input devices of Temperature Controllers.
Select from a wide variety of Temperature Sensors according
to the temperature to be measured, location, and environment,
and also according to the type and shape of the terminal.
Ordering Information
List of Models
Note: 1. Exclusive models are provided on the following page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
Classifi-
cation
Descrip-
tion
Model and appearance Tempera-
ture range
(See note 3.)
Element
type
Conduc-
tor type
Class Protective
tubing
material
Terminal
type
Page
General-
purpose
Models
Sheathed
platinum
resistance
thermom-
eter
E52-P@AY 196°C to
450°C
Pt100 3-conduc-
tor system
B SUS316 Exposed
lead wires
5
E52-P@C-N 200°C to
450°C
ASTM316L Enclosed
terminals
6
E52-P@B-N Exposed
terminals
Standard
platinum
resistance
thermom-
eter
E52-P@C-N 0°C to 450°C SUS316 Enclosed
terminals
7
Sheathed
thermo-
couple
E52-CA@AY
E52-IC@AY
0°C to 900°CK (CA)
J (IC)
Non-
grounded
type
2 (0.75) ASTM316L Exposed
lead wires
9 to
12
E52-CA@B-N
E52-IC@B-N
Exposed
terminals
13
E52-CA@C-N
E52-IC@C-N
Enclosed
terminals
Standard
thermo-
couple
E52-CA@B-N
E52-IC@B-N
SUS316 Exposed
terminals
14
E52-CA@C-N
E52-IC@C-N
Enclosed
terminals
15
E52-PR@C-N 0°C to
1,400°C
R (PR) 2 (0.25) JIS ceramic
JIS special
ceramic
Enclosed
terminals
16
Low-cost
Models
Low-cost
platinum
resistance
thermom-
eter
E52-P10AEY 0°C to 250°C Pt100 3-conduc-
tor system
B SUS316 Exposed
lead wires
17
E52-P6DY 50°C to
250°C
SUS304
E52-P6FY
Low-cost
thermo-
couple
E52-CA@ASY
E52-IC@ASY
0°C to 400°CK (CA)
J (IC)
Non-
grounded
type
2 (0.75) 18
E52-CA1DY
E52-IC1DY
Grounded
type
19
E52-CA6F-N
E52-IC6F-N
E52-CA6D-N
E52-IC6D-N
20
E52-CA10AE-N
E52-IC10AE-N
Non-
grounded
type
Refer to Safety Precautions for All Temperature
Controllers.
E52
2
Note: 1. General-purpose models and low-cost models are provided on the previous page.
2. These tables provide general specifications only. Be sure to read the detailed specifications and precautions before use.
3. The temperature range varies with the material, thickness, construction, and element type of the protective tubing.
Classifi-
cation
Descrip-
tion
Model and appearance Tempera-
ture range
(See note 3.)
Element
type
Conduc-
tor type
Class Protective
tubing
material
Terminal
type
Page
Exclusive
Models
Bayonet
spring for
molding
machines
E52-CA2GVY
E52-IC2GVY
0°C to 350°CK (CA)
J (IC)
Grounded
type
2 (0.75) SUS304 Exposed
lead wires
21
Crimping
terminals
E52-CA1GTY
E52-IC1GTY
0°C to 300°C---
Used for
measur-
ing surface
tempera-
tures
E52-P2GSY 50°C to
250°C
Pt100 3-conduc-
tor system
BSUS304
Used for
room tem-
perature
measure-
ment
E52-P10GRY 50°C to
60°C
22
Double-el-
ement
model
E52-CA20AY-7 0°C to 900°C K (CA) Two non-
grounded
types
2 (0.75) ASTM316L 25
E52-P20AY-7 196°C to
250°C
Pt100 Two 3-con-
ductor
systems
B
E52-P20C-N-7 200°C to
450°C
Enclosed
terminals
26
Water-
proof mod-
el
E52-P10GPY 0°C to 70°C 3-conduc-
tor system
SUS304 Exposed
lead wires
22
E52-P5AY-40 50°C to
180°C
Fluororesin
tubing
23
Corrosion-
resistant
model
E52-P20AY-1 80°C to
180°C
E52-CA20AY-1 0°C to 180°CK (CA) Non-
grounded
type
2 (0.75)
Silicone-
covered
lead wires
E52-CA1DY-40 0°C to 300°C Grounded
type
SUS304 26
E52-CA1GTY-14
0°C to 200°C---
Explosion-
proof mod-
el
E52-P
@@
C-N-6
--- Pt100 3-conduc-
tor system
B ASTM316L Enclosed
terminals
24
E52-CA
@@
C-N-6
--- K (CA) Non-
grounded
type
2 (0.75)
Thermistors E52-THE5A
E52-THE6F
E52-THE6D
50°C to
300°C
Ther-
mistor
Element-
inter-
change-
able
thermistor
1 SUS304 Exposed
lead wires
28
3
E52
Accessories
It is recommended that the following accessories be used for mounting Temperature Sensors.
Accessory Temperature
range
Mounting example Page
Compression
Fitting
600°C max. Mounting with
Compression
Fitting
Note: The Compression Fitting is not
of airtight construction. Do not
use the Compression Fitting for
applications in which the
exposure of the sensing object
will cause problems.
29
Loose Flange 400°C max. Mounting with
Loose Flange
Note: 1. Use the Loose Flange in
normal atmospheric
pressure. The Loose
Flange is not of airtight
construction.
2. Use the Loose Flange at
400°C max.
3. Do not apply the Loose
Flange to protective tubing
diameters other than the
applicable ones.
Compression Fitting
PT screw
Welding
Terminal box
Protective tubing
Loose Flange
Mounting screw
Terminal box
Protective tubing
E52
4
General-purpose Models
Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Platinum Resistance Thermometers
1. Element type
P: Pt100
2. Protective tubing length (L)
Specify the length in centimeters within the following range:
Unit (cm)
E52-@@AY
E52-@@B-N
E52-@@C-N
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
B-N: Exposed terminals
C-N: Enclosed terminals
4. Diameter
3.2: 3.2-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
4.8: 4.8-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
6.4: 6.4-mm dia. (Protective tubing construction: Sheathed)
E52-@@AY and E52-@@C-N only
8: 8-mm dia. (Protective tubing construction: Sheathed)
E52-@@B-N and E52-@@C-N only
10: 10-mm dia. (Protective tubing construction: Standard)
E52-@@C-N only
5. Heat resistance
Specify for E52-@@AY model only.
6. Lead length (M)
Specify the length in meters within the following range for the E52-
@@AY only:
Range: 0.5, 1 to 100 m
Examples
Element: Pt100, protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-P42AY D=4.8 NETU 10M
Sheathed Platinum Resistance Thermometers
Refer to Model Number Legend above for the Pt100.
Specifications
E52-@@@ D=@@@M
123 4 56
Diameter (D) Length (L)
3.2 7 to 100
4.8 10 to 600
6.4 13 to 1,300
Diameter (D) Length (L)
8 20 to 100
Diameter (D) Length (L)
3.2 12 to 100
4.8 15 to 600
6.4 18 to 1,300
8 21 to 100
10 26 to 100
Code Temperature range Lead type
--- 20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU 0°C to 180°C
Sleeve: 0°C to 100°C
Glass-wool-covered,
externally shielded with
stainless
Element type Pt100
Class JIS class B
Sheath material SUS316 (E52-P@AY)
ASTM316L (E52-P@B-N, E52-P@C-N)
Sheath outer diameter 3.2 dia., 4.8 dia., 6.4 dia., 8 dia
Conductor type 3-conductor system
Temperature range 200°C to 450°C (in dry air)
5
E52
Exposed-lead Models
E52-P@AY
Dimensions
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
1248
Model
Exposed-lead
Models
3.2 dia. 15 Standard E52-P15AY D=3.2
1M
E52-P15AY D=3.2
2M
E52-P15AY D=3.2
4M
E52-P15AY D=3.2
8M
Heat resistive E52-P15AY D=3.2
NETU 1M
E52-P15AY D=3.2
NETU 2M
E52-P15AY D=3.2
NETU 4M
E52-P15AY D=3.2
NETU 8M
20 Standard E52-P20AY D=3.2
1M
E52-P20AY D=3.2
2M
E52-P20AY D=3.2
4M
E52-P20AY D=3.2
8M
Heat resistive E52-P20AY D=3.2
NETU 1M
E52-P20AY D=3.2
NETU 2M
E52-P20AY D=3.2
NETU 4M
E52-P20AY D=3.2
NETU 8M
35 Standard E52-P35AY D=3.2
1M
E52-P35AY D=3.2
2M
E52-P35AY D=3.2
4M
E52-P35AY D=3.2
8M
Heat resistive E52-P35AY D=3.2
NETU 1M
E52-P35AY D=3.2
NETU 2M
E52-P35AY D=3.2
NETU 4M
E52-P35AY D=3.2
NETU 8M
4.8 dia. 20 Standard E52-P20AY D=4.8
1M
E52-P20AY D=4.8
2M
E52-P20AY D=4.8
4M
E52-P20AY D=4.8
8M
Heat resistive E52-P20AY D=4.8
NETU 1M
E52-P20AY D=4.8
NETU 2M
E52-P20AY D=4.8
NETU 4M
E52-P20AY D=4.8
NETU 8M
35 Standard E52-P35AY D=4.8
1M
E52-P35AY D=4.8
2M
E52-P35AY D=4.8
4M
E52-P35AY D=4.8
8M
Heat resistive E52-P35AY D=4.8
NETU 1M
E52-P35AY D=4.8
NETU 2M
E52-P35AY D=4.8
NETU 4M
E52-P35AY D=4.8
NETU 8M
50 Standard E52-P50AY D=4.8
1M
E52-P50AY D=4.8
2M
E52-P50AY D=4.8
4M
E52-P50AY D=4.8
8M
Heat resistive E52-P50AY D=4.8
NETU 1M
E52-P50AY D=4.8
NETU 2M
E52-P50AY D=4.8
NETU 4M
E52-P50AY D=4.8
NETU 8M
6.4 dia. 20 Standard E52-P20AY D=6.4
1M
E52-P20AY D=6.4
2M
E52-P20AY D=6.4
4M
E52-P20AY D=6.4
8M
Heat resistive E52-P20AY D=6.4
NETU 1M
E52-P20AY D=6.4
NETU 2M
E52-P20AY D=6.4
NETU 4M
E52-P20AY D=6.4
NETU 8M
35 Standard E52-P35AY D=6.4
1M
E52-P35AY D=6.4
2M
E52-P35AY D=6.4
4M
E52-P35AY D=6.4
8M
Heat resistive E52-P35AY D=6.4
NETU 1M
E52-P35AY D=6.4
NETU 2M
E52-P35AY D=6.4
NETU 4M
E52-P35AY D=6.4
NETU 8M
50 Standard E52-P50AY D=6.4
1M
E52-P50AY D=6.4
2M
E52-P50AY D=6.4
4M
E52-P50AY D=6.4
8M
Heat resistive E52-P50AY D=6.4
NETU 1M
E52-P50AY D=6.4
NETU 2M
E52-P50AY D=6.4
NETU 4M
E52-P50AY D=6.4
NETU 8M
Y-type crimp terminal for M3.5
Maker tube
Red (A)
White (B)
Black (B) M
Lead wire
d
L
SUS304 sleeve Sheath (SUS316)
D
Unit (mm)
Ddl
3.2 dia. 8 40
4.8 dia. 8 40
6.4 dia. 8 40
Lead Wire
Standard (20°C to 70°C):
Fully vinyl-covered with twelve 0.18-dia
conductors (0.3 mm thick) and 4.8 mm
in outer dia. The sleeve resists a
temperature range between 0°C and
70°C.
Heat Resistive (0°C to 180°C):
Fully glass-wool-covered with thirty
0.12-dia. conductors (0.3 mm thick)
externally shielded with stainless steel,
4 mm in outer dia. The sleeve resists a
temperature range between 0°C and
100°C.
Lead Wire Length (M): 1, 2, 4, or 8 m
E52
6
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: 1. The terminals in the cap indicate polarity (A, B, b).
2. The length L is in centimeters, but “35” is 35 millimeters.
Therefore, for the E52-P35C-N: L = 35 (cm), the sheath length L 35 = 350 35 = 315 mm.
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Exposed-terminal Models
E52-P@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-P35B-N: L = 35 (cm), the sheath length L 40 = 350 40 = 310 mm.
Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Model
Enclosed-terminal
Models
20 E52-P20C-N D=3.2 E52-P20C-N D=4.8 E52-P20C-N D=6.4 E52-P20C-N D=8
35 E52-P35C-N D=3.2 E52-P35C-N D=4.8 E52-P35C-N D=6.4 E52-P35C-N D=8
50 E52-P50C-N D=3.2 E52-P50C-N D=4.8 E52-P50C-N D=6.4 E52-P50C-N D=8
75 --- E52-P75C-N D=4.8 E52-P75C-N D=6.4 ---
Sheath (ASTM316L)
Cap
Use wiring terminals that fit M3 screws.
G
3
/
8
,
Packing internal
diameter 6.5 dia.
Terminal box
(See note 2.)
Caulking
Socket (SUS304)
Chain
D
67 15
66
40 L-35
A
B
b
3-M3
45
42.5
17.6 L-40
D
Terminal box
Product label
Caulking
Socket (SUS304)
Sheath (ASTM316L)
(See note.)
15
Model Information
Custom-made models are available on request. Refer to page 4 for
details
Terminal
type
Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
8 dia.
Model
Exposed-
terminal
Models
20 E52-P20B-N D=8
35 E52-P35B-N D=8
50 E52-P50B-N D=8
Terminal box: The permissible temperature is 0°C to 100°C.
7
E52
Standard Platinum Resistance Thermometers
Refer to Model Number Legend on page 4 for the Pt100.
Specifications
Note: 1. Use the sheathed platinum resistance thermometer if
condensation is likely to result.
2. Be sure that the thermometer is free of vibration or shock if
high temperatures are measured.
Enclosed-terminal Models
E52-P@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: 1. The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P75C-N: L = 75 (cm), the protective tubing length L 50 = 750 50 = 700 mm.
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (A, B, B).
Model Information
Custom-made models are available on request. Refer to page 4 for details.
Element type Pt100
Class JIS class B (See note 2.)
Protective tubing material SUS316
Conductor type 3-conductor system
Temperature range 0°C to 450°C (in dry air)
Terminal type Protective tubing
length L (cm)
Protective tubing
diameter D (mm)
10 dia.
Model
Enclosed-terminal
Models
35 E52-P35C-N D=10
50 E52-P50C-N D=10
75 E52-P75C-N D=10
100 E52-P100C-N D=10
D
SUS316 protective tubing
(See note 1.)
86
96
53
5
L-50
Cap
G1/2,
Packing internal
diameter 9 dia.
Terminal box
Socket (SUS304)
Chain
E52
8
Model Number Legend
The type of resistance thermometer, protective tubing length, and lead length can be specified as shown below.
Thermocouples
1. Element type
CA:K
IC: J
PR:R
2. Protective tubing length (L)
Specify the length in centimeters in the following range: Unit (cm)
E52-@@AY (Exposed-lead Model)
E52-@@B-N and E52-@@C-N (except E52-PR@C-N)
E52-PR@C-N
3. Terminal
AY: Exposed lead wires (Y-type crimp terminal for M3.5)
(element type: K, J)
B-N: Exposed terminals (element type: K, J)
C-N: Enclosed terminals (element type: K, J, R)
4. Diameter
Specify the protective tubing material according to the table.
5. Heat resistance
Specify this item for the exposed-lead models only.
6. Lead length (M)
Specify the length in meters in the following range for the E52-
@@AY only.
Range: 1 to 100 m
7. Protective tubing material
Examples
Element: K; protective tubing length: 420 mm, exposed leads, protective tubing dia.: 4.8 mm, heat resistive, lead length: 10 m
E52-CA42AY D=4.8 NETU 10M
Element: J; protective tubing length: 360 mm, enclosed terminals, protective tubing dia.: 3.2
E52-IC36C-N D=3.2
Diameter (D) Length (L)
1 2 to 200
1.6 3 to 500
3.2 5 to 2,000
4.8 8 to 2,300
6.4 10 to 1,200
8 12 to 1,000
Diameter (D) Length (L)
3.2 11 to 2,000
4.8 14 to 2,300
6.4 16 to 1,200
8.0 18 to 1,000
10 21 to 126
12 24 to 126
15 29 to 156
22 39 to 206
Diameter (D) Length (L)
15 50, 75, 100
Code Diameter
(D)
Protective tubing
construction
Protective tubing
material
1 1 mm Sheathed ASTM316L
1.6 1.6 mm Sheathed ASTM316L
3.2 3.2 mm Sheathed ASTM316L
4.8 4.8 mm Sheathed ASTM316L
6.4 6.4 mm Sheathed ASTM316L
8 8 mm Sheathed ASTM316L
10 10 mm Standard SUS316, SUS310S
12 12 mm Standard SUS316, SUS310S
15 15 mm Standard SUS316, SUS310S
22 22 mm Standard SUS316, SUS310S
17 17 mm Standard PT1, PT0
Code Temperature range Lead type
--- 20°C to 70°C
Sleeve: 0°C to 70°C
Vinyl-covered
NETU 0°C to 150°C
Sleeve: 0°C to 100°C
Glass-wool-covered with exter-
nal shield of stainless
Code Protective tubing
material
Element type
--- ASTM316L K, J
SUS310S SUS310S K, D = 10 to 22
PT1 JIS ceramic Cat.1 R
PT0 JIS special ceramic R
9
E52
Sheathed Thermocouples
Specifications Permissible Temperature in Dry Air
Note: For details on the permissible temperature, refer to page D-5 of
Introduction of Temperature Controllers (Cat. No. H900).
Exposed-lead Models
E52-CA@AY
Dimensions
K (CA) Model Information (E52-CA@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element type K (CA), J(IC)
Class JIS class 2 (0.75)
Thermal contact Non-grounded type
Sheath material CA: ASTM316L
IC: ASTM316L
D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
1 dia. 650°C450°C
1.6 dia. 650°C450°C
3.2 dia. 750°C650°C
4.8 dia. 800°C750°C
6.4 dia. 800°C750°C
8.0 dia. 900°C750°C
Y-type crimp terminal for M3.5
Red (+)
White ()
M L
Lead wire (See note 1.) Sheath (ASTM316L)
D
d
SUS304 sleeve
(See note 2.)
Unit (mm)
Ddl
1 dia. 8 55
1.6 dia. 8 55
3.2 dia. 8 55
4.8 dia. 8 55
6.4 dia. 11 55
8 dia. 11 55
Permissible Temperature in Dry Air
D Element wire
K (CA)
ASTM316L
1 dia. 650°C
1.6 dia. 650°C
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C
Note: 1. Lead Wire (Compensating Conductor)
Standard (20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between 20°C and 70°C
for standard models and 0°C and 100°C for heat-resistive models.
Terminal type Protective
tubing diameter
D (mm)
Protective
tubing length L
(cm)
Lead wire type Lead wire length M (m)
1248
Model
Exposed-lead
Models
1 dia. 15 Standard E52-CA15AY D=1 1M E52-CA15AY D=1 2M E52-CA15AY D=1 4M E52-CA15AY D=1 8M
Heat resistive E52-CA15AY D=1
NETU 1M
E52-CA15AY D=1
NETU 2M
E52-CA15AY D=1
NETU 4M
E52-CA15AY D=1
NETU 8M
20 Standard E52-CA20AY D=1 1M E52-CA20AY D=1 2M E52-CA20AY D=1 4M E52-CA20AY D=1 8M
Heat resistive E52-CA20AY D=1
NETU 1M
E52-CA20AY D=1
NETU 2M
E52-CA20AY D=1
NETU 4M
E52-CA20AY D=1
NETU 8M
35 Standard E52-CA35AY D=1 1M E52-CA35AY D=1 2M E52-CA35AY D=1 4M E52-CA35AY D=1 8M
Heat resistive E52-CA35AY D=1
NETU 1M
E52-CA35AY D=1
NETU 2M
E52-CA35AY D=1
NETU 4M
E52-CA35AY D=1
NETU 8M
1.6 dia. 15 Standard E52-CA15AY D=1.6
1M
E52-CA15AY D=1.6
2M
E52-CA15AY D=1.6
4M
E52-CA15AY D=1.6
8M
Heat resistive E52-CA15AY D=1.6
NETU 1M
E52-CA15AY D=1.6
NETU 2M
E52-CA15AY D=1.6
NETU 4M
E52-CA15AY D=1.6
NETU 8M
20 Standard E52-CA20AY D=1.6
1M
E52-CA20AY D=1.6
2M
E52-CA20AY D=1.6
4M
E52-CA20AY D=1.6
8M
Heat resistive E52-CA20AY D=1.6
NETU 1M
E52-CA20AY D=1.6
NETU 2M
E52-CA20AY D=1.6
NETU 4M
E52-CA20AY D=1.6
NETU 8M
35 Standard E52-CA35AY D=1.6
1M
E52-CA35AY D=1.6
2M
E52-CA35AY D=1.6
4M
E52-CA35AY D=1.6
8M
Heat resistive E52-CA35AY D=1.6
NETU 1M
E52-CA35AY D=1.6
NETU 2M
E52-CA35AY D=1.6
NETU 4M
E52-CA35AY D=1.6
NETU 8M
E52
10
Exposed-lead
Models
3.2 dia. 15 Standard E52-CA15AY D=3.2
1M
E52-CA15AY D=3.2
2M
E52-CA15AY D=3.2
4M
E52-CA15AY D=3.2
8M
Heat resistive E52-CA15AY D=3.2
NETU 1M
E52-CA15AY D=3.2
NETU 2M
E52-CA15AY D=3.2
NETU 4M
E52-CA15AY D=3.2
NETU 8M
20 Standard E52-CA20AY D=3.2
1M
E52-CA20AY D=3.2
2M
E52-CA20AY D=3.2
4M
E52-CA20AY D=3.2
8M
Heat resistive E52-CA20AY D=3.2
NETU 1M
E52-CA20AY D=3.2
NETU 2M
E52-CA20AY D=3.2
NETU 4M
E52-CA20AY D=3.2
NETU 8M
35 Standard E52-CA35AY D=3.2
1M
E52-CA35AY D=3.2
2M
E52-CA35AY D=3.2
4M
E52-CA35AY D=3.2
8M
Heat resistive E52-CA35AY D=3.2
NETU 1M
E52-CA35AY D=3.2
NETU 2M
E52-CA35AY D=3.2
NETU 4M
E52-CA35AY D=3.2
NETU 8M
50 Standard E52-CA50AY D=3.2
1M
E52-CA50AY D=3.2
2M
E52-CA50AY D=3.2
4M
E52-CA50AY D=3.2
8M
Heat resistive E52-CA50AY D=3.2
NETU 1M
E52-CA50AY D=3.2
NETU 2M
E52-CA50AY D=3.2
NETU 4M
E52-CA50AY D=3.2
NETU 8M
4.8 dia. 20 Standard E52-CA20AY D=4.8
1M
E52-CA20AY D=4.8
2M
E52-CA20AY D=4.8
4M
E52-CA20AY D=4.8
8M
Heat resistive E52-CA20AY D=4.8
NETU 1M
E52-CA20AY D=4.8
NETU 2M
E52-CA20AY D=4.8
NETU 4M
E52-CA20AY D=4.8
NETU 8M
35 Standard E52-CA35AY D=4.8
1M
E52-CA35AY D=4.8
2M
E52-CA35AY D=4.8
4M
E52-CA35AY D=4.8
8M
Heat resistive E52-CA35AY D=4.8
NETU 1M
E52-CA35AY D=4.8
NETU 2M
E52-CA35AY D=4.8
NETU 4M
E52-CA35AY D=4.8
NETU 8M
50 Standard E52-CA50AY D=4.8
1M
E52-CA50AY D=4.8
2M
E52-CA50AY D=4.8
4M
E52-CA50AY D=4.8
8M
Heat resistive E52-CA50AY D=4.8
NETU 1M
E52-CA50AY D=4.8
NETU 2M
E52-CA50AY D=4.8
NETU 4M
E52-CA50AY D=4.8
NETU 8M
6.4 dia. 20 Standard E52-CA20AY D=6.4
1M
E52-CA20AY D=6.4
2M
E52-CA20AY D=6.4
4M
E52-CA20AY D=6.4
8M
Heat resistive E52-CA20AY D=6.4
NETU 1M
E52-CA20AY D=6.4
NETU 2M
E52-CA20AY D=6.4
NETU 4M
E52-CA20AY D=6.4
NETU 8M
35 Standard E52-CA35AY D=6.4
1M
E52-CA35AY D=6.4
2M
E52-CA35AY D=6.4
4M
E52-CA35AY D=6.4
8M
Heat resistive E52-CA35AY D=6.4
NETU 1M
E52-CA35AY D=6.4
NETU 2M
E52-CA35AY D=6.4
NETU 4M
E52-CA35AY D=6.4
NETU 8M
50 Standard E52-CA50AY D=6.4
1M
E52-CA50AY D=6.4
2M
E52-CA50AY D=6.4
4M
E52-CA50AY D=6.4
8M
Heat resistive E52-CA50AY D=6.4
NETU 1M
E52-CA50AY D=6.4
NETU 2M
E52-CA50AY D=6.4
NETU 4M
E52-CA50AY D=6.4
NETU 8M
8 dia. 20 Standard E52-CA20AY D=8 1M E52-CA20AY D=8 2M E52-CA20AY D=8 4M E52-CA20AY D=8 8M
Heat resistive E52-CA20AY D=8
NETU 1M
E52-CA20AY D=8
NETU 2M
E52-CA20AY D=8
NETU 4M
E52-CA20AY D=8
NETU 8M
35 Standard E52-CA35AY D=8 1M E52-CA35AY D=8 2M E52-CA35AY D=8 4M E52-CA35AY D=8 8M
Heat resistive E52-CA35AY D=8
NETU 1M
E52-CA35AY D=8
NETU 2M
E52-CA35AY D=8
NETU 4M
E52-CA35AY D=8
NETU 8M
50 Standard E52-CA50AY D=8 1M E52-CA50AY D=8 2M E52-CA50AY D=8 4M E52-CA50AY D=8 8M
Heat resistive E52-CA50AY D=8
NETU 1M
E52-CA50AY D=8
NETU 2M
E52-CA50AY D=8
NETU 4M
E52-CA50AY D=8
NETU 8M
Terminal type Protective
tubing diameter
D (mm)
Protective
tubing length L
(cm)
Lead wire type Lead wire length M (m)
1248
Model
11
E52
Exposed-lead Models
E52-IC@AY
Dimensions
J (IC) Model Information (E52-IC@AY)
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
124
Model
Exposed-lead
Models
1 dia. 15 Standard E52-IC15AY D=1 1M E52-IC15AY D=1 2M E52-IC15AY D=1 4M
Heat resistive E52-IC15AY D=1 NETU
1M
E52-IC15AY D=1 NETU
2M
E52-IC15AY D=1 NETU
4M
20 Standard E52-IC20AY D=1 1M E52-IC20AY D=1 2M E52-IC20AY D=1 4M
Heat resistive E52-IC20AY D=1 NETU
1M
E52-IC20AY D=1 NETU
2M
E52-IC20AY D=1 NETU
4M
35 Standard E52-IC35AY D=1 1M E52-IC35AY D=1 2M E52-IC35AY D=1 4M
Heat resistive E52-IC35AY D=1 NETU
1M
E52-IC35AY D=1 NETU
2M
E52-IC35AY D=1 NETU
4M
1.6 dia. 15 Standard E52-IC15AY D=1.6 1M E52-IC15AY D=1.6 2M E52-IC15AY D=1.6 4M
Heat resistive E52-IC15AY D=1.6 NETU
1M
E52-IC15AY D=1.6 NETU
2M
E52-IC15AY D=1.6 NETU
4M
20 Standard E52-IC20AY D=1.6 1M E52-IC20AY D=1.6 2M E52-IC20AY D=1.6 4M
Heat resistive E52-IC20AY D=1.6 NETU
1M
E52-IC20AY D=1.6 NETU
2M
E52-IC20AY D=1.6 NETU
4M
35 Standard E52-IC35AY D=1.6 1M E52-IC35AY D=1.6 2M E52-IC35AY D=1.6 4M
Heat resistive E52-IC35AY D=1.6 NETU
1M
E52-IC35AY D=1.6 NETU
2M
E52-IC35AY D=1.6 NETU
4M
Y-type crimp terminal for M3.5
Red (+)
White ()
M L
D
Sheath (ASTM316L)
d
Lead wire (See note 1.)
SUS304 sleeve
(See note 2.)
Unit (mm)
Ddl
1 dia. 8 55
1.6 dia. 8 55
3.2 dia. 8 55
4.8 dia. 8 55
6.4 dia. 11 55
8 dia. 11 55
Permissible Temperature in Dry Air
D Element wire
J (IC)
ASTM316L
1 dia. 450°C
1.6 dia. 450°C
3.2 dia. 650°C
4.8 dia. 750°C
6.4 dia. 750°C
8.0 dia. 750°C
Note: 1. Lead Wire (Compensating Conductor)
Standard (20°C to 70°C):
Fully vinyl-covered with seven 0.3-dia. conductors (0.5 mm
thick) and external dimensions of 2.4 × 4.1.
Heat Resistive (0°C to 150°C):
Fully glass-wool-covered with seven 0.3-dia. conductors
(0.5 mm thick) with external shield of stainless steel and
external dimensions of 2.8 × 4.6
The heat-resistive lead wires cannot be used in locations
exposed to water or other liquids.
Lead Wire Length (M): 1, 2, 4, or 8 m
2. The sleeve resists temperatures ranging between 20°C and
70°C for standard models and 0°C and 100°C for heat-resistive
models.
E52
12
Exposed-lead
Models
3.2 dia. 15 Standard E52-IC15AY D=3.2 1M E52-IC15AY D=3.2 2M E52-IC15AY D=3.2 4M
Heat resistive E52-IC15AY D=3.2 NETU
1M
E52-IC15AY D=3.2 NETU
2M
E52-IC15AY D=3.2 NETU
4M
20 Standard E52-IC20AY D=3.2 1M E52-IC20AY D=3.2 2M E52-IC20AY D=3.2 4M
Heat resistive E52-IC20AY D=3.2 NETU
1M
E52-IC20AY D=3.2 NETU
2M
E52-IC20AY D=3.2 NETU
4M
35 Standard E52-IC35AY D=3.2 1M E52-IC35AY D=3.2 2M E52-IC35AY D=3.2 4M
Heat resistive E52-IC35AY D=3.2 NETU
1M
E52-IC35AY D=3.2 NETU
2M
E52-IC35AY D=3.2 NETU
4M
50 Standard E52-IC50AY D=3.2 1M E52-IC50AY D=3.2 2M E52-IC50AY D=3.2 4M
Heat resistive E52-IC50AY D=3.2 NETU
1M
E52-IC50AY D=3.2 NETU
2M
E52-IC50AY D=3.2 NETU
4M
4.8 dia. 20 Standard E52-IC20AY D=4.8 1M E52-IC20AY D=4.8 2M E52-IC20AY D=4.8 4M
Heat resistive E52-IC20AY D=4.8 NETU
1M
E52-IC20AY D=4.8 NETU
2M
E52-IC20AY D=4.8 NETU
4M
35 Standard E52-IC35AY D=4.8 1M E52-IC35AY D=4.8 2M E52-IC35AY D=4.8 4M
Heat resistive E52-IC35AY D=4.8 NETU
1M
E52-IC35AY D=4.8 NETU
2M
E52-IC35AY D=4.8 NETU
4M
50 Standard E52-IC50AY D=4.8 1M E52-IC50AY D=4.8 2M E52-IC50AY D=4.8 4M
Heat resistive E52-IC50AY D=4.8 NETU
1M
E52-IC50AY D=4.8 NETU
2M
E52-IC50AY D=4.8 NETU
4M
6.4 dia. 20 Standard E52-IC20AY D=6.4 1M E52-IC20AY D=6.4 2M E52-IC20AY D=6.4 4M
Heat resistive E52-IC20AY D=6.4 NETU
1M
E52-IC20AY D=6.4 NETU
2M
E52-IC20AY D=6.4 NETU
4M
35 Standard E52-IC35AY D=6.4 1M E52-IC35AY D=6.4 2M E52-IC35AY D=6.4 4M
Heat resistive E52-IC35AY D=6.4 NETU
1M
E52-IC35AY D=6.4 NETU
2M
E52-IC35AY D=6.4 NETU
4M
50 Standard E52-IC50AY D=6.4 1M E52-IC50AY D=6.4 2M E52-IC50AY D=6.4 4M
Heat resistive E52-IC50AY D=6.4 NETU
1M
E52-IC50AY D=6.4 NETU
2M
E52-IC50AY D=6.4 NETU
4M
8 dia. 20 Standard E52-IC20AY D=8 1M E52-IC20AY D=8 2M E52-IC20AY D=8 4M
Heat resistive E52-IC20AY D=8 NETU
1M
E52-IC20AY D=8 NETU
2M
E52-IC20AY D=8 NETU
4M
35 Standard E52-IC35AY D=8 1M E52-IC35AY D=8 2M E52-IC35AY D=8 4M
Heat resistive E52-IC35AY D=8 NETU
1M
E52-IC35AY D=8 NETU
2M
E52-IC35AY D=8 NETU
4M
50 Standard E52-IC50AY D=8 1M E52-IC50AY D=8 2M E52-IC50AY D=8 4M
Heat resistive E52-IC50AY D=8 NETU
1M
E52-IC50AY D=8 NETU
2M
E52-IC50AY D=8 NETU
4M
Terminal type Protective
tubing
diameter D
(mm)
Protective
tubing length
L (cm)
Lead wire
type
Lead wire length M (m)
124
Model
13
E52
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA50B-N: L = 50 (cm), the sheath length L 40 = 500 40 = 460 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which
is provided in centimeters. Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or ).
Note: The length L is in centimeters, but “40” is 40 millimeters.
Therefore, for the E52-CA35C-N: L = 35 (cm), the sheath length L 40 = 350 40 = 310 mm.
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Two, M3
L-40
44
38.5
16
D
Sheath
(ASTM316L)
Terminal box
Caulking
15
(See note)
+
Socket (SUS304)
D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
3.2 dia. 750°C650°C
4.8 dia. 800°C750°C
6.4 dia. 800°C750°C
8.0 dia. 900°C750°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Model
K (CA) Exposed-ter-
minal Models
20 E52-CA20B-N D=3.2 E52-CA20B-N D=4.8 E52-CA20B-N D=6.4 ---
35 E52-CA35B-N D=3.2 E52-CA35B-N D=4.8 E52-CA35B-N D=6.4 E52-CA35B-N D=8
50 E52-CA50B-N D=3.2 E52-CA50B-N D=4.8 E52-CA50B-N D=6.4 E52-CA50B-N D=8
75 --- E52-CA75B-N D=4.8 E52-CA75B-N D=6.4 E52-CA75B-N D=8
J (IC) Exposed-ter-
minal Models
20 E52-IC20B-N D=3.2 E52-IC20B-N D=4.8 E52-IC20B-N D=6.4 ---
35 E52-IC35B-N D=3.2 E52-IC35B-N D=4.8 E52-IC35B-N D=6.4 E52-IC35B-N D=8
50 E52-IC50B-N D=3.2 E52-IC50B-N D=4.8 E52-IC50B-N D=6.4 E52-IC50B-N D=8
75 --- E52-IC75B-N D=4.8 E52-IC75B-N D=6.4 E52-IC75B-N D=8
Use wiring terminals that fit M3 screws.
66
67
40
D
L-40
Sheath
(ASTM316L)
G
3
/
8
,
Packing internal
diameter 6.5 dia.
Terminal box
Caulking
Socket (SUS304)
Chain
(See note)
D Element wire
K (CA)
ASTM316L
J (IC)
ASTM316L
3.2 dia. 750°C650°C
4.8 dia. 800°C750°C
6.4 dia. 800°C750°C
8.0 dia. 900°C750°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
3.2 dia. 4.8 dia. 6.4 dia. 8 dia.
Model
K (CA) Enclosed-ter-
minal Models
20 E52-CA20C-N D=3.2 E52-CA20C-N D=4.8 E52-CA20C-N D=6.4 ---
35 E52-CA35C-N D=3.2 E52-CA35C-N D=4.8 E52-CA35C-N D=6.4 E52-CA35C-N D=8
50 E52-CA50C-N D=3.2 E52-CA50C-N D=4.8 E52-CA50C-N D=6.4 E52-CA50C-N D=8
75 --- E52-CA75C-N D=4.8 E52-CA75C-N D=6.4 E52-CA75C-N D=8
J (IC) Enclosed-ter-
minal Models
20 E52-IC20C-N D=3.2 E52-IC20C-N D=4.8 E52-IC20C-N D=6.4 ---
35 E52-IC35C-N D=3.2 E52-IC35C-N D=4.8 E52-IC35C-N D=6.4 E52-IC35C-N D=8
50 E52-IC50C-N D=3.2 E52-IC50C-N D=4.8 E52-IC50C-N D=6.4 E52-IC50C-N D=8
75 --- E52-IC75C-N D=4.8 E52-IC75C-N D=6.4 E52-IC75C-N D=8
E52
14
Standard Thermocouples
Specifications
Note: Specify PT1 or PT0 if the element is R.
Permissible Temperature in Dry Air (See note.)
Note: For details on the permissible temperature, refer to Technical
Guide for Temperature Sensors.
Exposed-terminal Models
E52-CA@B-N
E52-IC@B-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Terminal box: The permissible temperature is 0°C to 100°C.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA75B-N: L = 75 (cm), the protective tubing length L 50 = 750 50 = 700 mm.
Permissible Temperature in Dry Air
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details.
Element wire K (CA), J(IC), R
Class K (CA), J (IC) JIS class 2 (0.75)
R, JIS class 2 (0.25)
Protective tubing material K (CA) SUS316
J (IC) SUS316
R (See
note.)
JIS ceramic cat. 1 (PT1)
JIS special ceramic (PT0)
Thermal contact Non-grounded type
D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 750°C 450°C
12 dia. 850°C 500°C
15 dia. 850°C 550°C
22 dia. 900°C 600°C
D Element wire
R
15 dia. 0°C to 1,400°C
D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 750°C 450°C
12 dia. 850°C 500°C
15 dia. 850°C 550°C
22 dia. 900°C 600°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia. 12 dia. 15 dia. 22 dia.
Model
K (CA) Exposed-ter-
minal Models
35 E52-CA35B-N D=10 E52-CA35B-N D=12 E52-CA35B-N D=15 ---
50 E52-CA50B-N D=10 E52-CA50B-N D=12 E52-CA50B-N D=15 E52-CA50B-N D=22
75 E52-CA75B-N D=10 E52-CA75B-N D=12 E52-CA75B-N D=15 E52-CA75B-N D=22
100 E52-CA100B-N D=10 E52-CA100B-N D=12 E52-CA100B-N D=15 E52-CA100B-N D=22
J (IC) Exposed-ter-
minal Models
35 E52-IC35B-N D=10 E52-IC35B-N D=12 E52-IC35B-N D=15 ---
50 E52-IC50B-N D=10 E52-IC50B-N D=12 E52-IC50B-N D=15 E52-IC50B-N D=22
75 E52-IC75B-N D=10 E52-IC75B-N D=12 E52-IC75B-N D=15 E52-IC75B-N D=22
100 E52-IC100B-N D=10 E52-IC100B-N D=12 E52-IC100B-N D=15 E52-IC100B-N D=22
49.5
Two, M4
SUS316 protective tubing
5
L-50
+
70
25
D
Terminal box
(See note)
Socket (SUS304)
15
E52
Enclosed-terminal Models
E52-CA@C-N
E52-IC@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-CA50C-N: L = 50 (cm), the protective tubing length L 50 = 500 50 = 450 mm.
Permissible Temperature in Dry Air
Terminal box: The permissible temperature is 0°C to 90°C.
Note: The terminals in the cap indicate polarity (+ or ).
Model Information
Custom-made models are available on request. Refer to Model Number Legend on page 8 for details
D Element wire
K (CA) SUS316 J (IC) SUS316
10 dia. 0 to 750°C 0 to 450°C
12 dia. 0 to 850°C 0 to 500°C
15 dia. 0 to 850°C 0 to 550°C
22 dia. 0 to 900°C 0 to 600°C
Element type Terminal type Protective
tubing length
L (cm)
Protective tubing diameter D (mm)
10 dia. 12 dia. 15 dia. 22 dia.
Model
K (CA) Enclosed-ter-
minal Models
35 E52-CA35C-N D=10 E52-CA35C-N D=12 E52-CA35C-N D=15 ---
50 E52-CA50C-N D=10 E52-CA50C-N D=12 E52-CA50C-N D=15 E52-CA50C-N D=22
75 E52-CA75C-N D=10 E52-CA75C-N D=12 E52-CA75C-N D=15 E52-CA75C-N D=22
100 E52-CA100C-N D=10 E52-CA100C-N D=12 E52-CA100C-N D=15 E52-CA100C-N D=22
J (IC) Enclosed-ter-
minal Models
35 E52-IC35C-N D=10 E52-IC35C-N D=12 E52-IC35C-N D=15 ---
50 E52-IC50C-N D=10 E52-IC50C-N D=12 E52-IC50C-N D=15 E52-IC50C-N D=22
75 E52-IC75C-N D=10 E52-IC75C-N D=12 E52-IC75C-N D=15 ---
100 E52-IC100C-N D=10 E52-IC100C-N D=12 E52-IC100C-N D=15 ---
SUS316 protective tubing
86
96
53 L-50
D
Socket (SUS304)
Chain
G
1
/
2
,
Packing internal diameter 9 dia.
Terminal box
40 dia.
(See note)
5
E52
16
Enclosed-terminal Models (High-temperature Use)
E52-PR@C-N
Dimensions
Dimensions are given in millimeters, except for the length (L), which is provided in centimeters.
Note: The length L is in centimeters, but “150” is 150 millimeters.
Therefore, for the E52-PR75C-N: L = 75 (cm), the protective tubing length L 150 = 750 150 = 600 mm.
Model Information
Note: The permissible temperature given for the protective tubing is
higher than 1,400°C, but the permissible temperature of the
thermocouple element wire is only 1,400°C. Therefore, the
protective tubing of the E52-PR@C-N can withstand high
temperatures momentarily to the levels given in the table as
exceptions, but the element wire will deteriorate quickly if the
thermocouple is used regularly at temperatures that exceed the
permissible temperature for the element wire.
Use wiring terminals that fit M4 screws.
15 dia.
40 dia.
SUS304
22 dia.
86
96
53 100
When L = 500
Swing of protective tube: 6 mm or less
Filled with heat resistant cement
L-150
G
1
/
2
,
Packing internal diameter 9 dia.
Terminal box
Chain
Porcelain protective tube
(See note)
5
Lock nut (SUS304)
Permissible
Temperature in Dry Air
Terminal box: The
permissible temperature
is 0°C to 90°C.
Note: The terminals in
the cap indicate
polarity (+ or ).
D Element wire
R
15 dia. 0°C to 1,400°C
Element
type
Terminal
type
Protective
tubing
length L
(cm)
Protective tubing
diameter D (mm)
15 dia.
Model
R (See
note 1.)
Enclosed-ter-
minal Models
50 E52-PR50C-N D=15 PT1
75 E52-PR75C-N D=15 PT1
100 E52-PR100C-N D=15 PT1
R (See
note 2.)
Enclosed-ter-
minal Models
50 E52-PR50C-N D=15 PT0
75 E52-PR75C-N D=15 PT0
100 E52-PR100C-N D=15 PT0
Standard Protective tubing
material
Permissible
temperature in dry
air
Note 1:
JIS ceramic Cat.1
(PT1)
Mullite, high
alumina, etc.
1,500°C (See note.)
Note 2:
JIS special ceramic
(PT0)
Recrystallized
alumina, fused
alumina, etc.
1,700°C (See note.)
17
E52
Low-cost Models
Low-cost Platinum Resistance Thermometers
Exposed-lead Models with Screws
Exposed-lead Models with Flange
Exposed-lead Models
Specifications
Element type Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS304
Sensor length 30 mm
Max. detectable
temperature
250°C
Temperature
range
50°C to 250°C
Lead wire 50°C to 150°C
E52-P6DY
Dimensions
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m) Model
1 E52-P6DY 1M
2 E52-P6DY 2M
4 E52-P6DY 4M
14
4 dia.
Argon arc welding
Silicone tubing
Caulking
65 10 6
15
30
Red (A)
Black (B)
Black (B)
M
SUS304 (t0.25)
Tapered pipe thread
SUS304
R
1
/
8
Fluororesin-covered wire
with 1.0 outer dia. each
(PFA) 7/0.18
Y-type crimp
terminal for M3.5
Specifications
Element wire Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS304
Sensor length 30 mm
Max. detectable
temperature
250°C
Temperature
range
50°C to 250°C
Lead wire 50°C to 150°C
E52-P6FY
Dimensions
Note: The protective tubing is of pipe construction, which must not be bent.
Lead wire length (m) Model
1 E52-P6FY 1M
2 E52-P6FY 2M
4 E52-P6FY 4M
SUS304
Silicone tubing
Caulking Red (A)
White (B)
White (B)
4 dia.
65
1
15
30
M
SUS304 (t0.25)
120° 120°
Three, 3.5 dia.
Flange
20 dia.
30 dia.
Silver
soldering
Fluororesin-covered wire
with 1.0 outer dia. each
(PFA) 7/0.18
Y-type crimp
terminal for M3.5
Specifications
Element type Pt100
Conductor type 3-conductor system
Class Class B
Protective tubing
material
SUS316
Max. detectable
temperature
250°C
Temperature
range
0°C to 250°C
Lead wire 50°C to 180°C
E52-P10AEY
Dimensions
Note: 1. The protective tubing is of pipe construction, which must not be bent.
2. A Compression Fitting (PT@) cannot be used for mounting.
Lead wire length (m) Model
1 E52-P10AEY 1M
2 E52-P10AEY 2M
4 E52-P10AEY 4M
3.2 dia.
Caulking
Red (A)
White (B)
White (B)
Silicone
shrinkable tubing
Fluororesin-covered wire with 1.0 outer dia.
each (PFA) 7/0.2
Y-type crimp
terminal for M3.5
B
A
B
100 M
(30)
Shrinkable tube (black)
Product label
Marker tube
E52
18
Low-cost Thermocouples
Exposed-lead Models with Spring
Note: The protective tubing is of pipe construction, which must not be bent.
Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC)
Model
65 1 E52-CA6ASY 1M E52-IC6ASY 1M
2 E52-CA6ASY 2M E52-IC6ASY 2M
4 E52-CA6ASY 4M E52-IC6ASY 4M
100 1 E52-CA10ASY 1M E52-IC10ASY 1M
2 E52-CA10ASY 2M E52-IC10ASY 2M
4 E52-CA10ASY 4M E52-IC10ASY 4M
150 1 E52-CA15ASY 1M E52-IC15ASY 1M
2 E52-CA15ASY 2M E52-IC15ASY 2M
4 E52-CA15ASY 4M E52-IC15ASY 4M
200 1 E52-CA20ASY 1M E52-IC20ASY 1M
2 E52-CA20ASY 2M E52-IC20ASY 2M
4 E52-CA20ASY 4M E52-IC20ASY 4M
+
L±3
Lead Wire(Red)
Lead Wire
(White)
12 dia. 150
80
32
4.8 dia. Sleeve
(+)
()
M
SUS304 (t0.4)
Brass-nickel
plating
Closely wound
spring coil
Fully glass-wool-covered
compensating cable with
four 0.65-dia. conductors
and external dimensions
of approx. 5.1 × 3.0
Color code
(K: Blue, J: Yellow)
Y-type crimp
terminal for M3.5
Marker tube(White)
Marker tube(White)
Specifications
Note: The sleeve resists temperatures ranging
between 0°C and 100°C.
Element type K (CA), J (IC)
Element dia. 0.65 mm (single wire)
Class Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact Non-grounded type
Temperature range 0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire 0°C to 180°C
E52-CA@ASY, E52-IC@ASY
Dimensions
L: Protective tubing length
M: Lead wire length
19
E52
Exposed-lead Models with Screw
Protective tubing length (mm) Lead wire length (m) Element type: K (CA) Element type: J (IC)
Model
M6 screw 1 E52-CA1DY M6 1M E52-IC1DY M6 1M
2 E52-CA1DY M6 2M E52-IC1DY M6 2M
4 E52-CA1DY M6 4M E52-IC1DY M6 4M
M8 screw 1 E52-CA1DY M8 1M E52-IC1DY M8 1M
2 E52-CA1DY M8 2M E52-IC1DY M8 2M
4 E52-CA1DY M8 4M E52-IC1DY M8 4M
W1/4 screw 1 E52-CA1DY W1/4 1M E52-IC1DY W1/4 1M
2 E52-CA1DY W1/4 2M E52-IC1DY W1/4 2M
4 E52-CA1DY W1/4 4M E52-IC1DY W1/4 4M
Crimp terminal for M3.5
80
Red (+)
White ()
M
Brass
10
1 A C
B
2.8
3.8 dia.
5 dia.
0.65-dia.
thermocouple
element
Movable ring
(brass)
SUS304
screw
(W1/4) Enamel-bonded
copper wire
Color tubing
(K: Blue,
J: Yellow)
Fully glass-wool-covered with external
copper shield and external dimensions of
approx. 3.1 × 2.0
Color code
(K: Blue,
J: Yellow)
End Workpiece
Brass
0.65-dia.
black wire
Movable ring
Cut after silver
soldering
M6
Screw
Closely wound
enamel-bonded coil.
Brass pipe
Shielded
glass-wool lead
wire
Specifications
Note: 1. The thermocouple is a single wire from
the tip to the terminal.
2. Specify the type of screw (i.e., M6, M8,
or W1/4) when ordering.
3. The thermocouple is not of airtight
construction.
4. OMRON recommends that the tip of the
thermocouple is touching the sensing
object.
Installation Example
Cut a thread into the workpiece, and screw in the
thermocouple while pushing in so that the tip
makes complete contact.
Element type K (CA), J (IC)
Element dia. 0.65 mm (single wire)
Class Class 2 (0.75)
Protective tubing
material
SUS304
Thermal contact Grounded type
Temperature range 0°C to 400°C: K (CA)
0°C to 350°C: J (IC)
Lead wire 0°C to 180°C
Terminal shape Y-type crimp terminal
for M3.5
E52-CA1DY, E52-IC1DY
Dimensions
Lead wire
length (m)
Screw
W1/4 M6 M8
A (mm) 4.3 4 5.3
B (mm) 11.5 11.5 15
C (mm) 3.8 3.8 3.8
Note: E52-CA1DY with the same shape and multiple element wires are also available (E52-CA1DY-40).
Refer to page 26 for details.
Internal Construction (E52-CA1DY)
E52
20
Exposed-lead Models with Flange
Exposed-lead Models with Screws
Exposed-lead Models
Specifications
Element type K (CA), J (IC)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C: K
(CA)
0°C to 350°C: J
(IC)
Lead wire 0°C to 150°C
E52-CA6F-N, E52-IC6F-N
Dimensions
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA6F-N 1M E52-IC6F-N 1M
2 E52-CA6F-N 2M E52-IC6F-N 2M
4 E52-CA6F-N 4M E52-IC6F-N 4M
20 dia.
30 dia.
Three, 3.5 dia.
4 dia.
Silver soldering
Lead wire length (M): 1, 2, or 4 m
White ()
Red (+)
120°
120°
110
Peel processed
Caulking
SUS304
SUS304
15
80±1030
65±2 M
Shrinkable
tube
Silicon
shrinkable tube
Fluororesin-covered thermocouple wire with external
dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)
Specifications
Element type K (CA), J (IC)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C: K
(CA)
0°C to 350°C: J
(IC)
Lead wire 0°C to 150°C
E52-CA6D-N, E52-IC6D-N
Dimensions
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. The protective tubing is of pipe construction, which must not be bent.
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA6D-N 1M E52-IC6D-N 1M
2 E52-CA6D-N 2M E52-IC6D-N 2M
4 E52-CA6D-N 4M E52-IC6D-N 4M
4 dia.
Shrinkable
tube
Lead wire length (M): 1, 2, or 4 m
White ()
Red (+)
Tapered pipe
thread
SUS304
R 1/8
14
610
15
80±1030
65±2 M
Caulking
Silicon
shrinkable tube
Fluororesin-covered thermocouple wire with external
dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)
Peel processed
Specifications
Element type K (CA), J (IC)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Non-grounded
type
Temperature
range
0°C to 350°C: K
(CA)
0°C to 200°C: J
(IC)
Lead wire 0°C to 180°C
E52-CA10AE-N, E52-IC10AE-N
Dimensions
Note: 1. The thermocouple is a single wire from the tip to the terminal.
2. Lead wire length M: 1, 2, or 4 m
3. The protective tubing is of pipe construction, which must not be bent.
4. The thermocouple cannot be mounted using a PT@ Compression Fitting.
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA10AE-N 1M E52-IC10AE-N 1M
2 E52-CA10AE-N 2M E52-IC10AE-N 2M
4 E52-CA10AE-N 4M E52-IC10AE-N 4M
3.2 dia.
Caulking
SUS304 Shrinkable
tube
White ()
Red (+)
80
10
100 M
Fluororesin-covered thermocouple wire with external
dimensions of 1.6 × 1.0 (CA) and 1.6 × 1.0 (IC)
Peel processed
Protective tubing
21
E52
Exclusive Models
Thermocouples
Thermocouples for Molding Machines
Thermocouples with Crimp Terminals
Platinum Resistance Thermometers
Platinum Resistance Thermometers for Surface Temperature Measurement
+
Shrinkable tube
6.8 dia.
15 dia.
14 dia.
12.5 dia.
Bayonet
4.8 dia.
12 dia.8 dia.
5 dia.
4.1 dia.
Lead wire length (M): 1 or 2 m
SUS304
Spring
Springretainer
Glass-coveredstainlesssteelshielded
thermocouplewire
M
25±2 15 22
10
10
15
100±10 85±10
18
R/
Y-typecrimp
terminalforM3.5
Markertube
White ()
Red (+)
Adapter (provided)
(See note.)
Specifications
Element type K (CA), J (IC)
Element
diameter
1.0 mm (single
wire)
Class Class 2 (0.75)
Protective
tubing material
SUS304
Thermal contact Grounded type
Temperature
range
0°C to 350°C
Lead wire 0°C to 180°C
E52-CA2GVY, E52-IC2GVY
Dimensions
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA2GVY 1M E52-IC2GVY 1M
2 E52-CA2GVY 2M E52-IC2GVY 2M
Note: The Adapter is included
with the Thermocouple.
If it is lost or damaged,
you can order a
replacement with the
following model number.
Adapter: Y92F-S1
Specifications
Note: The E52-CA1GTY is also
available with double elements.
Refer to page 26 for details.
Element type K (CA), J (IC)
Element
diameter
0.65 mm (single
wire)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature
range
0°C to 300°C
Lead wire 0°C to 150°C
Terminal shape Y-type crimp
terminal for M3.5
E52-CA1GTY, E52-IC1GTY
Dimensions
Lead wire
length (m)
Element type: K (CA) Element type: J (IC)
Model
1 E52-CA1GTY 1M E52-IC1GTY 1M
2 E52-CA1GTY 2M E52-IC1GTY 2M
M
15
4.3 dia.
M4, round crimp terminal
80
8Silicone tubing
6 dia. max.
Glass-wool-braided shield with maximum
external dimensions of 2.6 × 4.0
Color code
(K: Blue, J: Yellow)
Lead wire length (M): 1 or 2 m
Y-type crimp
terminal for M3.5
White/red stripe (+)
White stripe ()
Specifications
Element type Pt100
Class Class B
Protective
tubing material
SUS304
With brass-nickel-
plated bracket
Conductor type 3-conductor
system
Temperature
range
50°C to 250°C
Lead wire 50°C to 150°C
E52-P2GSY
Dimensions
Lead wire length (m) Model
1 E52-P2GSY 1M
2 E52-P2GSY 2M
30 M80
30
1.5 4.50
20±1
14±0.6
6
3
55 B
A
B
20±0.5
28±1
Caulking
Four, 3.2 dia.
Brass-nickel-plated bracket
Red (A)
White (B)
White (B)
6-dia.
Silicone-covered 3-conductor cable
with thirty 0.08-dia. conductors (0.15-mm thick)
and approx. 3.9 dia.
Lead wire length (M): 1 or 2 m
Silicon shrinkable tube
Product label
Name plate A
Marker tube
E52
22
Platinum Resistance Thermometers for Room Temperature Measurement
Waterproof Platinum Resistance Thermometers
42±1 dia.
70±1
dia.
27
dia.
Two
,
8
dia.
6.1
dia.
4.8 dia.
Red (A)
White (B)
Black (B)
6.1-outer-dia.
vinyl-covered 3-conductor
cable (twenty 0.18-dia.
conductors, 0.5 mm thick)
Y-type crimp
terminal for M3.5
(30)
100
69.5±1
97 2,000
95 85±10
56
22.2
dia.
BS (Ni plated)
8.0
dia.
SUS304
Enclosed resistance
thermometer
Shrinkable
tube
Marker tube
A
B
B
Aluminum alloy
AC3A
Specifications
Element type Pt100
Class Class B
Protective tubing
material
SUS304
Conductor type 3-conductor system
Temperature range 50°C to 60°C
Lead wire 20°C to 60°C
E52-P10GRY
Dimensions
Lead wire length (m) Model
2 E52-P10GRY 2M
Specifications
Element wire Pt100
Class Class B
Protective tubing
material
SUS304
Conductor type 3-conductor system
Temperature range 0°C to 70°C (underwater)
20°C to 70°C (in the air)
Lead wire 25°C to 60°C
Resistive pressure 10 kg/cm2 max.
E52-P10GPY
Dimensions
Note: The lead wires are vinyl-covered, and cannot be used underwater.
Use the E52-P5AY-40 if waterproof lead wires are required for use underwater.
Refer to page 23 for details.
Lead wire length (m) Model
2 E52-P10GPY 2M
4 E52-P10GPY 4M
Red (A)
White (B)
White (B)
20 dia.
6.1 dia.
7 dia.
6.1-outer-dia. vinyl-covered
3-conductor cable (twelve 0.18-dia.
conductors, 0.5 mm thick)
Y-type crimp
terminal for M3.5
Lead wire length (M): 2 or 4 m
100 62
98
(30)
85±10
12
5M
B
B
A
SUS304 protective tubing
Name plate
Marker tube
Shrinkable
tube
23
E52
Corrosion-resistant Models with Fluororesin-covered
Protective Tubing
Thermocouples
Exposed-lead Models
Platinum Measurement
Exposed-lead Models
FEP-molded Models (Completely Waterproof)
Fixed with adhesive tape and
silicone heat-shrinking tube
Red (+)
White ()
SleeveSheath
FEP-covered tubing
Y-type crimp
terminal for M3.5 Compensating
conductor dD
+
2,000 200
Caulking
90±10
Product label
Filled with epoxy resin
E52-CA20AY-1
Dimensions
Model Protective
tubing
diameter
Sleeve diameter
(mm)
Sleeve length
(mm)
Covering
thickness
(mm)
Lead wire
length (m)
E52-CA20AY-1 D=4.6 2M
D = 4.6 d = 8
l = 55
0.7 2
E52-CA20AY-1 D=6 2M D = 6.0 0.6
E52-CA20AY-1 D=8 2M D = 8.0 d = 11
l = 55
0.8
Specifications
Element type K (CA)
Class Class 2 (0.75)
Protective tubing
material
ASTM316L with
Fluororesin-covered
(FEP) tube
Thermal contact Non-grounded type
Temperature range 0°C to 180°C
Lead wire Vinyl-covered: 20°C
to 70°C
Fixed with adhesive tape and
silicone heat-shrinking tube
Lead wires SleeveSheath
FEP-covered tubing
Red
White
White
Y-type crimp
terminal for M3.5
A
B
B
d
(9.5 dia.)
D
2,000 35 205
85±10
Filled with epoxy resin
Marker tube
Shrinkable tube
E52-P20AY-1
Dimensions
Model Protective
tubing
diameter
Sleeve
diameter
(mm)
Coating
thickness
(mm)
Lead wire
length (m)
E52-P20AY-1 D=4.6 2M D = 4.6 d = 8 0.7 2
E52-P20AY-1 D=6 2M D = 6.0 d = 8 0.6
E52-P20AY-1 D=8 2M D = 8.0 d = 8 0.8
Specifications
Element type Pt100
Class Class B
Protective tubing
material
SUS316 with
Fluororesin-covered
(FEP) tube
Conductor type 3-conductor system
Temperature range 80°C to 180°C
Lead wire Vinyl-covered: 20°C
to 70°C
3.5 dia.6 dia.
PFA-covered wire 0.18/7
Red (A)
White (B)
White (B)
Y-type crimp terminal for M3.5
B
A
B
M
90±10
80
65
30±5
Element FEP mold
Fused (completely waterproof) Product label
Marker tube
E52-P5AY-40
Dimensions
Model Lead wire length (m)
E52-P5AY-40 2M 2
E52-P5AY-40 4M 4
E52-P5AY-40 6M 6
E52-P5AY-40 8M 8
Specifications
Element type Pt100
Class Class B
Protective tubing
material
Fluororesin (FEP) tube
(element / fluororesin
mold (FEP))
Conductor type 3-conductor system
Temperature range 50°C to 180°C
Lead wire
Fluororesin (FEP)
cover (with outer
cover)
: 50°C to 180°C
E52
24
Pressure-resistant Explosion-proof (IICT6) Models
Thermocouples
Enclosed-terminal Models
Platinum Resistance Thermometers for Surface Temperature Measurement
Enclosed-terminal Models
6.4 dia. 15 dia.
L2
L
10
70
L1
131.5
113
113
64.6
G1/2
Sheath
(ASTM316L) SUS304 O-ring
Socket (SUS304)
Specifications
Element type K (CA)
Class Class 2 (0.75)
Class 3 (Level 1.5) at -40
°
C
and under
Protective tubing material L2 section: ASTM316L
L1 section: SUS304
Explosion-
proof
specifica-
tions
Construction Pressure-resistant
explosion-proof structure
Explosion-protected
class and ignitability
IICT6
Explosion-proof
temperature range
20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread G1/2
Installation method Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
Model Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
E52-CA20C-N-6 D=6.4 L2=150 20 D = 6.4 150
E52-CA35C-N-6 D=6.4 L2=300 35 D = 6.4 300
E52-CA50C-N-6 D=6.4 L2=450 50 D = 6.4 450
E52-CA75C-N-6 D=6.4 L2=700 75 D = 6.4 700
E52-CA@@C-N-6
Dimensions
Model Protective
tubing length
L (cm)
Protective
tubing
diameter
L2
(mm)
E52-P20C-N-6 D=6.4 L2=150 20 D = 6.4 150
E52-P35C-N-6 D=6.4 L2=300 35 D = 6.4 300
E52-P50C-N-6 D=6.4 L2=450 50 D = 6.4 450
E52-P75C-N-6 D=6.4 L2=700 75 D = 6.4 700
6.4 dia. 15 dia.
L2
L
70
131.5
64.6
L1
113
G
1
/
2
10
O-ring
Socket (SUS304)
Sheath
(ASTM316L)
SUS304
Specifications
Element type Pt100
Class Class B
Protective tubing material L2 section: ASTM316L
L1 section: SUS304
Explosion-
proof
specifica-
tions
Construction Pressure-resistant
explosion-proof structure
Explosion-protected
class and ignitability
IICT6
Explosion-proof
temperature range
20°C to 85°C
Lead wire wiring
method
Pressure-resistant
packing cable ground type
Conduit thread G1/2
Installation method Conforms to Technical
Recommendations of the
Research Institute of
Industrial Safety (Japan)
E52-P@@C-N-6
Dimensions
25
E52
Double-element Models
Thermocouple
Exposed-lead Models
Platinum Resistance Thermometers
Exposed-lead Models
E52-CA20AY-7
Dimensions
Specifications
Element type K (CA)
Class Class 2 (0.75)
Protective tubing
material
ASTM316L
(with sheath)
Thermal contact Non-grounded type
Temperature
range
0°C to permissible
temperature limit
Lead wire Vinyl-covered: 20°C
to 70°C
Sleeve
Red (+)
White ()
Red (+)
White ()
Compensating
conductor
Y-type crimp
terminal for M3.5
+
+
d
90±10 2,000
80
55 200
30
D
Sheath
(ASTM316L)
Product label
Marker tube
Permissible Temperature in Dry Air
DElement wire
K (CA)
ASTM316L
3.2 dia. 750°C
4.8 dia. 800°C
6.4 dia. 800°C
8.0 dia. 900°C
Model Protective
tubing
diameter
Sleeve
diameter
(mm)
Permissible
Temperature
(°C)
Lead wire
length (m)
E52-CA20AY-7 D=3.2 2M D = 3.2 d = 11 750 2
E52-CA20AY-7 D=4.8 2M D = 4.8 d = 11 800 2
E52-CA20AY-7 D=6.4 2M D = 6.4 d = 11 800 2
E52-CA20AY-7 D=8.0 2M D = 8.0 d = 11 900 2
Sleeve (SUS304)
Caulking
Y-type crimp
terminal for M3.5
1
2
B
A
A
B
B
B
90±10
80
55 200±6
M
30
6.5 dia. 11 dia.
D
Sheath
(ASTM316L)
Red (A)
White (B)
White (B)
Red (A)
White (B)
White (B)
Silicon shrinkable tube
Lead wire with
all-vinyl coating
Filled with epoxy resin
Marker tube
Wire marks (1, 2)
Indicated by pair
Product label
E52-P20AY-7
Dimensions
Specifications
Element type Pt100
Class Class B
Protective tubing
material
ASTM316L
(with sheath)
Conductor type 3-conductor system
Temperature
range
200°C to 450°C
Lead wire Vinyl-covered: 20°C
to 70°C
Model Protective
tubing diameter
Lead wire
length (m)
E52-P20AY-7 D=4.8 2M D = 4.8 2
E52-P20AY-7 D=6.4 2M D = 6.4 2
E52
26
Enclosed-terminal Models
Note: The length L is in centimeters, but “50” is 50 millimeters.
Therefore, for the E52-P20C-N-7: L = 20 (cm), the sheath length L 50 = 200 50 = 150 mm.
Silicone-covered Lead Wires Models
Thermocouples
Exposed-lead Models with Screws
Specifications
Note: Refer to the installation example for the E52-CA1DY.
E52-CA1DY-40
Dimensions
Thermocouples with Crimp Terminals
Specifications E52-CA1GTY-14
Dimensions
Lead wire length (M): 1 or 2 m
Terminal box
82 dia.
Socket (SUS304)
86
96
53 L-50
Terminal for terminal connection
Size: M4
D
Caulking
Sheath (ASTM316L)
15
(See note)
E52-P20C-N-7
Dimensions
Specifications
Element type Pt100
Class Class B
Protective tubing
material
ASTM316L
(with sheath)
Conductor type 3-conductor system
Temperature range 200°C to 450°C
Model Protective tubing
length L (cm)
Protective
tubing diameter
E52-P20C-N-7 D=4.8 20 D = 4.8
E52-P20C-N-7 D=6.4 20 D = 6.4
Element type K (CA)
Class Class 2 (0.75)
Screw material SUS304
Thermal contact Grounded type
Temperature range 0°C to 300°C
Lead wire Silicone-covered (0.1/30): 0°C to
150°C
Terminal shape Y-type crimp terminal for M3.5
Model Screw pitch Lead wire
length (m)
E52-CA1DY-40 M6 1M M6 1
E52-CA1DY-40 M6 2M M6 2
E52-CA1DY-40 M6 4M M6 4
11
2.8 10 13 80 Silicone
covering
Silicone
covering
M
80
4.2 1
3.8 dia.
Movable ring SUS304 screw
8 dia. Caulking SUS304
spring with
6.5 outer dia.
and 5.2
inside dia. Silicone
shrinkable tubing
Y-type crimp
terminal for 3.5
Thermo-
couple
element
wire
Red (+)
White ()
Element type K (CA)
Class Class 2 (0.75)
Thermal contact Grounded type
Temperature range 0°C to 200°C
Lead wire Silicone-covered : 0°C to 150°C
Terminal shape Y-type crimp terminal for M3.5
Model Lead wire length (m)
E52-CA1GTY-14 1M 1
E52-CA1GTY-14 2M 2
8
15
M
30 80
M4, round,
crimp terminal
Red (+)
White ()
Silicone-covered
compensating cable with
twenty 0.18-dia.
conductors and external
dimensions of 5.5 dia.
Color tubing
Blue CA (K)
Y-type crimp
terminal for M3.5
4.3 dia.
27
E52
Thermistors
Element Interchangeable Thermistor for E5CS and E5C2
Temperature Ranges
Specifications
Error
Permissible Temperature
Note: Models with non-standard lead wire length and protective
tubing length are available on request.
This Thermistor is a dedicated Thermistor for the E5C2 and E5CS.
Temperature
range
Color code Nominal resistance Thermistor
constant
Lead wire
50°C to 50°CBlue 6 kΩ (0°C) 3390K A pair of 0.12 dia. 7 Fluororesin-insulated stranded wires with
0.86 outer dia. each
0°C to 100°CBlack 6 kΩ (0°C) 3390K
50°C to 150°C Red 30 kΩ (0°C) 3450K
100°C to 200°C Yellow 0.55 kΩ (200°C) 4300K
150°C to 300°C Green 4 kΩ (200°C) 5133K Flat glass-wool-shielded lead cable with 0.12 dia. 10 conductors
and external dimensions of 2.5 × 1.55
Item E52-THE@@
Coupling method Element interchangeable thermistor
Class JIS class 1
Protective tubing material SUS304
Time constant 8 to 15 s in still water
Dissipation factor 2.4 to 2.8 mW/°C in still air
Lead wire heat resistive
temperature
180°C
Detectable temperature Error
50°C to 100°C±1°C max.
100°C to 350°C±1% max. of detectable temperature
Detectable temperature Operating temperature
50°C to 50°C 100°C
0°C to 100°C 150°C
50°C to 150°C 200°C
100°C to 200°C 250°C
150°C to 300°C 350°C
E52
28
Exposed-lead Models
E52-THE5A
Dimensions
Note: The lead wires have no polarity
Exposed-lead Models with Screws
E52-THE6D
Dimensions
Note: The lead wires have no polarity
Exposed-lead Models with Flange
E52-THE6F
Dimensions
Note: The lead wires have no polarity
Note: 1. The Thermistor lead cable can be extended with a standard lead wire for extension. If waterproof performance is required, be sure that
the lead cable joint is of waterproof construction as well.
2. Be sure to specify the model and temperature range when ordering the Thermistor. The Thermistor has a color code according to the
temperature range.
4 dia.
50 1,030
105015
SUS304 t0.25 Color code
Lead wires
(See note.)
Caulking
Temperature range Model
50°C to 50°C E52-THE5A 50-50°C 1M
0°C to 100°C E52-THE5A 0-100°C 1M
50°C to 150°C E52-THE5A 50-150°C 1M
100°C to 200°C E52-THE5A 100-200°C 1M
150°C to 300°C E52-THE5A 150-300°C 1M
65 15 1,000
105015
Tapered pipe thread
SUS304
R
1
/
8
14
4 dia.
Argon arc welding 10 6
SUS304 t0.25 Color code
Lead wires
(See note.)
Temperature range Model
50°C to 50°C E52-THE6D 50-50°C 1M
0°C to 100°C E52-THE6D 0-100°C 1M
50°C to 150°C E52-THE6D 50-150°C 1M
100°C to 200°C E52-THE6D 100-200°C 1M
150°C to 300°C E52-THE6D 150-300°C 1M
15 1,000
105015
65
1
SUS304 t0.25
SUS304
4 dia.
120°
20 dia.
30 dia.
Three, 3.5 dia.
120°Color code
Lead wires
(See note.)
Silver
soldering
Temperature range Model
50°C to 50°C E52-THE6F 50-50°C 1M
0°C to 100°C E52-THE6F 0-100°C 1M
50°C to 150°C E52-THE6F 50-150°C 1M
100°C to 200°C E52-THE6F 100-200°C 1M
150°C to 300°C E52-THE6F 150-300°C 1M
29
E52
Accessories
Compression Fittings
Model Information
Note: The Compression Fitting is not of airtight construction. Do not use the Compression Fitting for applications in which the exposure of the
sensing object will cause problems.
The compression fitting is a screw that adjusts and secures the
insertion length of Temperature Sensors with the above protective
tubing diameters.
The material of the Compression Fitting is SUS304 with internal
fixing beads made of brass.
Source: JIS B 0203 (Unit: mm)
Model Screw of part
a
Applicable
protective tubing
diameter
Dimension
b c d Flat diameter
Part c Part b
PT 1/8 D=1.0 R 1/8 1.0 dia. 5 13 10 14 14
PT 1/8 D=1.6 1.6 dia.
PT 1/8 D=3.2 3.2 dia.
PT 1/8 D=4.8 4.8 dia.
PT 1/4 D=3.2 R 1/4 3.2 dia. 5 15 12 17 14
PT 1/4 D=4.8 4.8 dia.
PT 1/4 D=6.4 6.4 dia.
PT 3/8 D=8 R 3/8 8 dia. 5 19 15 21 17
PT 1/2 D=10 R 1/2 10 dia. 8 23.5 19.5 26 21
M 12 D=4.8 M 12 4.8 dia. 5 15 12 17 14
Sensor side
Protective tubing dia.
Head side
a
bcd
D
Nomi-
nal
thread
size
T.P.I.
(No. of
threads
/inch)
Outer
diame-
ter: d
Effec-
tive
diame-
ter: d2
Root
diame-
ter: d1
Stan-
dard
diame-
ter
posi-
tion a
(from
pipe
end)
Mini-
mum
effec-
tive
screw
length:
f
PT 1/8 28 9.728 9.147 8.566 3.97
±0.91
2.5
PT 1/4 19 13.157 12.301 11.445 6.01
±1.34
3.7
PT 3/8 19 16.662 15.806 14.950 6.35
±1.34
3.7
PT 1/2 14 20.955 19.793 18.631 8.16
±1.81
5.0
Main body Retaining screw
SUS304
Material SUS304
Lock bead
Brass
Tighten using the retaining screw to
secure to the protective tubing.
d1
d2
d
af
Tapered thread
Standard dia.
E52
30
Loose Flanges
Model Information
Note: 1. Use the Loose Flange in atmospheric pressure. The Loose
Flange is not of airtight construction.
2. Use the Loose Flange at 400°C maximum.
3. Do not apply the Loose Flange to protective tubing
diameters other than the applicable ones.
Material: Aluminum
Applicable protective
tubing diameter
Model
3.2 dia. MF-1 D=3.2
4.8 dia. MF-1 D=4.8
6.4 dia. MF-1 D=6.4
8 dia. MF-1 D=8
10 dia. MF-2 D=10
12 dia. MF-2 D=12
15 dia. MF-2 D=15
22 dia. MF-2 D=22
120°
Three, 5 dia.
21 dia.
D dia.
23 dia.
36
45 dia.
514
M4
Three, 6.5 dia.
54 dia.
31 dia.
D dia.
35 dia.
70 dia.
24
6.6
M6
120°
MF-2MF-1
31
E52
Compensating Conductors
The material of the Compensating Conductor is the same as or similar to that of the Thermocouple. Therefore, the Thermocouple can be connected
to the Compensating Conductor just as if the length of the Thermocouple is to be extended. A standard model for a temperature range between
20°C and 70°C and two types of heat-resistive models for a temperature range between 0°C and 150°C are available.
Be sure to use the compensating conductor for the extension of the length of the thermocouple.
Model Information
Note: 1. Compensating Conductors with lengths, increased in units of a meter, up to 100 meters are available on request. Specify lengths above
100 meters in units of 100 meters. The maximum length depends on the product. Contact your OMRON representative for details.
2. It has the same waterproof characteristics as the standard model (fully vinyl-covered) and can be used at high temperatures.
Specifications (JIS C1610-1995)
Note: Symbols conform to JIS standards.
For code having duplicate exterior, check the application and check in our models.
Thermocouple Heat
resistance
Exterior Model
(Length) 1 m 2 m 4 m 8 m
R Standard Fully vinyl-covered (waterproof) WPRG-N 1M WPRG-N 2M WPRG-N 4M WPRG-N 8M
Heat resistive Fully glass-wool-covered WPRH-N 1M WPRH-N 2M WPRH-N 4M WPRH-N 8M
Fully glass-wool-covered with external shield
of stainless steel
WPRH6-N 1M WPRH6-N 2M WPRH6-N 4M WPRH6-N 8M
K (CA) Standard Fully vinyl-covered (waterproof) WCAG-N 1M WCAG-N 2M WCAG-N 4M WCAG-N 8M
Heat resistive Fully glass-wool-covered WCAH-N 1M WCAH-N 2M WCAH-N 4M WCAH-N 8M
Fully glass-wool-covered with external shield
of stainless steel
WCAH6-N 1M WCAH6-N 2M WCAH6-N 4M WCAH6-N 8M
Silicone-covered (See note 2.) WCAG-40 1M WCAG-40 2M WCAG-40 4M WCAG-40 8M
J (IC) Standard Vinyl covered (waterproof) WICG-N 1M WICG-N 2M WICG-N 4M WICG-N 8M
Heat resistive Fully glass-wool-covered WICH-N 1M WICH-N 2M WICH-N 4M WICH-N 8M
Fully glass-wool-covered with external shield
of stainless steel
WICH6-N 1M WICH6-N 2M WICH6-N 4M WICH6-N 8M
Model Type of
thermo-
couple
Use Code
(See note.)
Exterior Number of
wires/wire
diameter
Operating
temperature
range (°C)
Error (°C) Exterior
color
WPRG-N R Standard RCA-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 ±30 Black
WPRH-N Heat resistive RCB-2-H Fully glass-wool-covered 7/0.32 0 to 150 ±60
WPRH6-N Fully glass-wool-covered with
external shield of stainless steel
WCAG-N K (CA) Standard KCC-2-G Fully vinyl-covered (waterproof) 7/0.3 0 to 90 ±100 Blue
WCAH-N Heat resistive KCB-2-H Fully glass-wool-covered 7/0.32 0 to 150
WCAH6-N Fully glass-wool-covered with
external shield of stainless steel
WCAG-40 Heat resistive
for moving parts
KX-2-G Silicone-covered 30/0.1 20 to 150 ±100
WICG-N J (IC) Standard JX-2-G Fully vinyl-covered (waterproof) 7/0.3 20 to 90 ±140 Yellow
WICH-N Heat resistive JX-2-H Fully glass-wool-covered 7/0.32 0 to 150
WICH6-N Fully glass-wool-covered with
external shield of stainless steel
In the interest of product improvement, specifications are subject to change without notice.
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Terms and Conditions Agreement
Read and understand this catalog.
Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you
have any questions or comments.
Warranties.
(a) Exclusive Warranty. Omron’s exclusive warranty is that the Products will be free from defects in materials and workmanship
for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron
disclaims all other warranties, express or implied.
(b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT
NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER
ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE
PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE.
Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the
Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron’s sole obligation hereunder shall be, at
Omron’s election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or
replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount
equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty,
repair, indemnity or any other claims or expenses regarding the Products unless Omrons analysis confirms that the Products
were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate
modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall
not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or
electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice,
recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above
warranty.
See http://www.omron.com/global/ or contact your Omron representative for published information.
Limitation on Liability; Etc.
OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES,
LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS,
WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY.
Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted.
Suitability of Use.
Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the
combination of the Product in the Buyer’s application or use of the Product. At Buyer’s request, Omron will provide applicable
third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself
is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine,
system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product
with respect to Buyers application, product or system. Buyer shall take application responsibility in all cases.
NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE
QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS,
AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE
OVERALL EQUIPMENT OR SYSTEM.
Programmable Products.
Omron Companies shall not be responsible for the users programming of a programmable Product, or any consequence
thereof.
Performance Data.
Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining
suitability and does not constitute a warranty. It may represent the result of Omron’s test conditions, and the user must correlate
it to actual application requirements. Actual performance is subject to the Omron’s Warranty and Limitations of Liability.
Change in Specifications.
Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our
practice to change part numbers when published ratings or features are changed, or when significant construction changes are
made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers
may be assigned to fix or establish key specifications for your application. Please consult with your Omron’s representative at
any time to confirm actual specifications of purchased Product.
Errors and Omissions.
Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is
assumed for clerical, typographical or proofreading errors or omissions.
2014.10
In the interest of product improvement, specifications are subject to change without notice.
OMRON Corporation
Industrial Automation Company
http://www.ia.omron.com/
(c)Copyright OMRON Corporation 2014 All Right Reserved.
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron: