3-Phase, 3-Wire, and 4-Wire Energy Metering IC with Pulse Output ADE7752B FEATURES The only analog circuitry used in the ADE7752B is in the analog-to-digital converters (ADCs) and reference circuit. All other signal processing (for example, multiplication, filtering, and summation) is carried out in the digital domain. This approach provides superior stability and accuracy over extremes in environmental conditions and over time. The ADE7752B supplies average active power information on the low frequency outputs, F1 and F2. These logic outputs can be used to directly drive an electromechanical counter or to interface with a microcontroller (MCU). The CF logic output gives instantaneous active power information. This output is intended to be used for calibration purposes. The ADE7752B includes a power supply monitoring circuit on the VDD pin. The ADE7752B remains inactive until the supply voltage on VDD reaches 4 V. If the supply falls below 4 V, the ADE7752B resets and no pulses are issued on F1, F2, and CF. Internal phase matching circuitry ensures that the voltage and current channels are phase matched. An internal no load threshold ensures that the ADE7752B does not exhibit any creep when there is no load. The ADE7752B is available in a 24-lead SOIC package. High accuracy supports 50 Hz/60 Hz IEC 62053-21 Less than 0.1% error over a dynamic range of 500 to 1 Compatible with 3-phase, 3-wire delta and 3-phase, 4-wire Wye configurations Supplies average active power on the frequency outputs F1 and F2 High frequency output (CF) is intended for calibration and supplies instantaneous active power Logic output REVP indicates a potential miswiring or negative power on the sum of all phases Direct drive for electromechanical counters and 2-phase stepper motors (F1 and F2) Proprietary ADCs and DSP provide high accuracy over large variations in environmental conditions and time On-chip power supply monitoring On-chip creep protection (no load threshold) On-chip reference 2.4 V 8% (25 ppm/C typical) with external overdrive capability Single 5 V supply, low power (42.5 mW typical) Low cost CMOS process GENERAL DESCRIPTION The ADE7752B is a high accuracy polyphase electrical energy measurement IC. The ADE7752B specifications surpass the accuracy requirements as quoted in the IEC62053-21 standard. FUNCTIONAL BLOCK DIAGRAM IAP 5 ADC IAN 6 VAP 16 ADC HPF LPF ABS VDD 17 3 X POWER SUPPLY MONITOR ADE7752B IBP 7 IBN 8 ADC X HPF VBP 15 ADC 2 LPF DGND 19 CLKIN 20 CLKOUT ADC ICN 10 VCP 14 ADC VN 13 2.4V REF HPF X LPF 4k DIGITAL-TO-FREQUENCY CONVERTER 11 12 AGND REFIN/OUT 4 18 REVP SCF 22 21 23 24 1 S1 S0 F2 F1 CF 05905-001 ICP 9 Figure 1. Rev. 0 Information furnished by Analog Devices is believed to be accurate and reliable. However, no responsibility is assumed by Analog Devices for its use, nor for any infringements of patents or other rights of third parties that may result from its use. Specifications subject to change without notice. No license is granted by implication or otherwise under any patent or patent rights of Analog Devices. Trademarks and registered trademarks are the property of their respective owners. One Technology Way, P.O. Box 9106, Norwood, MA 02062-9106, U.S.A. Tel: 781.329.4700 www.analog.com Fax: 781.461.3113 (c)2007 Analog Devices, Inc. All rights reserved. ADE7752B TABLE OF CONTENTS Features .............................................................................................. 1 Voltage Channels........................................................................ 13 General Description ......................................................................... 1 Typical Connection Diagrams...................................................... 14 Functional Block Diagram .............................................................. 1 Current Channel Connection................................................... 14 Revision History ............................................................................... 2 Voltage Channel Connection.................................................... 14 Specifications..................................................................................... 3 Meter Connections..................................................................... 14 Timing Characteristics ................................................................ 4 Power Supply Monitor ................................................................... 16 Absolute Maximum Ratings............................................................ 5 HPF and Offset Effects .................................................................. 17 ESD Caution.................................................................................. 5 Digital-to-Frequency Conversion ................................................ 18 Pin Configuration and Function Descriptions............................. 6 Accumulation of 3-Phase Power .............................................. 19 Typical Performance Characteristics ............................................. 8 Transfer Function ........................................................................... 20 Terminology ...................................................................................... 9 Frequency Outputs F1 and F2 .................................................. 20 Test Circuit ...................................................................................... 10 Frequency Output CF ................................................................ 21 Theory of Operation ...................................................................... 11 Selecting a Frequency for an Energy Meter Application........... 22 Power Factor Considerations.................................................... 11 Frequency Outputs..................................................................... 22 Nonsinusoidal Voltage and Current ........................................ 12 No-Load Threshold.................................................................... 23 Analog Inputs.................................................................................. 13 Outline Dimensions ....................................................................... 24 Current Channels ....................................................................... 13 Ordering Guide .......................................................................... 24 REVISION HISTORY 8/07--Revision 0: Initial Version Rev. 0 | Page 2 of 24 ADE7752B SPECIFICATIONS VDD = 5 V 5%, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz, TMIN to TMAX = -40C to +85C, unless otherwise noted. Table 1. Parameter ACCURACY1, 2 Measurement Error on Current Channel Phase Error Between Channels PF = 0.8 Capacitive PF = 0.5 Capacitive AC Power Supply Rejection Output Frequency Variation (CF) DC Power Supply Rejection Output Frequency Variation (CF) ANALOG INPUTS Maximum Signal Levels Input Impedance (DC) Bandwidth (-3 dB) ADC Offset Error1, 2 Gain Error REFERENCE INPUT REFIN/OUT Input Voltage Range Input Impedance Input Capacitance ON-CHIP REFERENCE Reference Error Temperature Coefficient CLKIN (INPUT CLOCK FREQUENCY) LOGIC INPUTS3 SCF, S0, S1, and ABS Input High Voltage, VINH Input Low Voltage, VINL Input Current, IIN Input Capacitance, CIN LOGIC OUTPUTS3 F1 and F2 Output High Voltage, VOH Output Low Voltage, VOL CF and REVP Output High Voltage, VOH Output Low Voltage, VOL POWER SUPPLY VDD IDD 1 2 3 Conditions Min Typ Max 0.1 Voltage channel with full-scale signal (500 mV), 25C, over a dynamic range of 500 to 1 % reading 0.1 0.1 SCF = 0, S0 = S1 = 1 IA = IB = IC = 100 mV rms, VA = VB = VC = 100 mV rms @ 50 Hz, Ripple on VDD of 200 mV rms @ 100 Hz S1 = 1, S0 = SCF = 0 V1 = 100 mV rms, V2 = 100 mV rms, VDD = 5 V 250 mV See the Analog Inputs section VAP - VN, VBP - VN, VCP - VN, IAP - IAN, IBP - IBN, ICP - ICN CLKIN = 10 MHz CLKIN/256, CLKIN = 10 MHz % reading 0.1 % reading 590 14 25 External 2.5 V reference, IA = IB = IC = 500 mV dc 2.4 V + 8% 2.4 V - 8% Degrees Degrees 0.01 0.5 500 Unit 9 2.6 2.2 3.3 10 V peak difference k kHz mV % ideal V V k pF Nominal 2.4 V 200 25 10 All specifications for CLKIN of 10 MHz VDD = 5 V 5% VDD = 5 V 5% Typically 10 nA, VIN = 0 V to VDD 2.4 ISOURCE = 10 mA, VDD = 5 V ISINK = 10 mA, VDD = 5 V 4.5 VDD = 5 V, ISOURCE = 5 mA VDD = 5 V, ISINK = 5 mA For specified performance 5 V 5% 4.5 4.75 8.5 See the Terminology section for explanation of specifications. See the plots in the Typical Performance Characteristics section. Sample tested during initial release and after any redesign or process changes that might affect this parameter. Rev. 0 | Page 3 of 24 mV ppm/C MHz 0.8 3 10 V V A pF 0.5 V V 0.5 V V 5.25 10 V mA ADE7752B TIMING CHARACTERISTICS VDD = 5 V 5%, AGND = DGND = 0 V, on-chip reference, CLKIN = 10 MHz, TMIN to TMAX = -40C to +85C, unless otherwise noted. Table 2. Parameter1,2 t1 3 t2 t3 t43, 4 t55 t6 Conditions F1 and F2 pulse width (logic high) Output pulse period (see the Transfer Function section) Time between F1 rising edge and F2 rising edge CF pulse width (logic high) CF pulse period (see the Transfer Function section) Minimum time between F1 and F2 pulse Specification 120 See Figure 2 1/2 t2 90 See Table 7 4/CLKIN 1 Sample tested during initial release and after any redesign or process changes that might affect this parameter. See Figure 2. 3 The pulse widths of F1, F2, and CF are not fixed for higher output frequencies (see the Frequency Outputs section). 4 CF is not synchronous to F1 or F2 frequency outputs. 5 The CF pulse is always 1 s in the high frequency mode (see the Frequency Outputs section). 2 t1 F1 t6 t2 t3 t4 t5 05905-002 F2 CF Figure 2. Timing Diagram for Frequency Outputs Rev. 0 | Page 4 of 24 Unit ms sec sec ms sec sec ADE7752B ABSOLUTE MAXIMUM RATINGS TA = 25C, unless otherwise noted. Stresses above those listed under Absolute Maximum Ratings may cause permanent damage to the device. This is a stress rating only; functional operation of the device at these or any other conditions above those indicated in the operational section of this specification is not implied. Exposure to absolute maximum rating conditions for extended periods may affect device reliability. Table 3. Parameter VDD to AGND VDD to DGND Analog Input Voltage to AGND VAP, VBP, VCP, VN, IAP, IAN, IBP, IBN, ICP, and ICN Reference Input Voltage to AGND Digital Input Voltage to DGND Digital Output Voltage to DGND Operating Temperature Range, Industrial Storage Temperature Range Junction Temperature 24-Lead SOIC, Power Dissipation JA Thermal Impedance Lead Temperature, Soldering Vapor Phase (60 sec) Infrared (15 sec) Rating -0.3 V to +7 V -0.3 V to +7 V -6 V to +6 V -0.3 V to VDD + 0.3 V -0.3 V to VDD + 0.3 V -0.3 V to VDD + 0.3 V -40C to +85C -65C to +150C 150C 63 mW 55C/W ESD CAUTION 215C 220C Rev. 0 | Page 5 of 24 ADE7752B PIN CONFIGURATION AND FUNCTION DESCRIPTIONS CF 1 24 F1 DGND 2 23 F2 VDD 3 22 S1 21 S0 IAP 5 ADE7752B 20 CLKOUT IAN 6 TOP VIEW (Not to Scale) 19 CLKIN IBP 7 18 SCF IBN 8 17 ABS ICP 9 16 VAP ICN 10 15 VBP AGND 11 14 VCP REFIN/OUT 12 13 VN 05905-004 REVP 4 Figure 3. Pin Configuration Table 4. Pin Function Descriptions Pin No. 1 Mnemonic CF 2 DGND 3 VDD 4 REVP 5, 6; 7, 8; 9, 10 IAP, IAN; IBP, IBN; ICP, ICN 11 AGND 12 REFIN/OUT 13, 14, 15, 16 VN, VCP, VBP, VAP 17 ABS 18 SCF 19 CLKIN Description Calibration Frequency Logic Output. The CF logic output gives instantaneous active power information. This output is intended to be used for calibration purposes. This provides the ground reference for the digital circuitry in the ADE7752B, that is, multipliers, filters, and digital-to-frequency converters. Because the digital return currents in the ADE7752B are small, it is acceptable to connect this pin to the analog ground plane of the whole system. Power Supply. This pin provides the supply voltage for the digital circuitry in the ADE7752B. The supply voltage should be maintained at 5 V 5% for specified operation. This pin should be decoupled to DGND with a 10 F capacitor in parallel with a 100 nF ceramic capacitor. This logic output goes logic high when negative power is detected on the sum of the three phase powers. This output is not latched and resets when positive power is once again detected (see the Negative Total Power Detection section). Analog Inputs for Current Channels. These channels are intended for use with current transducers and are referenced in this document as current channels. These inputs are fully differential voltage inputs with maximum differential input signal levels of 0.5 V (see the Analog Inputs section). Both inputs have internal ESD protection circuitry; in addition, an overvoltage of 6 V can be sustained on these inputs without risk of permanent damage. This pin provides the ground reference for the analog circuitry in the ADE7752B (ADCs and reference). This pin should be tied to the analog ground plane or the quietest ground reference in the system. This quiet ground reference should be used for all analog circuitry, such as antialiasing filters and current and voltage transducers. To keep ground noise around the ADE7752B to a minimum, the quiet ground plane should connect to the digital ground plane at only one point. It is acceptable to place the entire device on the analog ground plane. This pin provides access to the on-chip voltage reference. The on-chip reference has a nominal value of 2.4 V 8% and a typical temperature coefficient of 25 ppm/C. An external reference source can also be connected at this pin. In either case, this pin should be decoupled to AGND with a 1 F ceramic capacitor. Analog Inputs for the Voltage Channels. These channels are intended for use with voltage transducers and are referenced in this document as voltage channels. These inputs are single-ended voltage inputs with a maximum signal level of 0.5 V with respect to VN for specified operation. All inputs have internal ESD protection circuitry; in addition, an overvoltage of 6 V can be sustained on these inputs without risk of permanent damage. This logic input is used to select the method by which the three active energies from each phase are summed. It selects between the arithmetical sum of the three energies (ABS logic high) or the sum of the absolute values (ABS logic low). See the Mode Selection of the Sum of the Three Active Energies section. Select Calibration Frequency. This logic input is used to select the frequency on the calibration output CF. Table 7 shows how the calibration frequencies are selected. Master Clock for the ADCs and Digital Signal Processing. An external clock can be provided at this logic input. Alternatively, a parallel resonant AT crystal can be connected across CLKIN and CLKOUT to provide a clock source for the ADE7752B. The clock frequency for the specified operation is 10 MHz. Ceramic load capacitors between 22 pF and 33 pF should be used with the gate oscillator circuit. Refer to the crystal manufacturer's data sheet for the load capacitance requirements. Rev. 0 | Page 6 of 24 ADE7752B Pin No. 20 Mnemonic CLKOUT 21, 22 S0, S1 23, 24 F2, F1 Description A crystal can be connected across this pin and CLKIN as described for Pin 19 to provide a clock source for the ADE7752B. The CLKOUT pin can drive one CMOS load when an external clock is supplied at CLKIN or when a crystal is used. These logic inputs are used to select one of four possible frequencies for the digital-to-frequency conversion for design flexibility. Low Frequency Logic Outputs. F1 and F2 supply average active power information. These logic outputs can be used to drive electromechanical counters and 2-phase stepper motors directly (see the Transfer Function section). Rev. 0 | Page 7 of 24 ADE7752B TYPICAL PERFORMANCE CHARACTERISTICS 0.5 0.5 0.4 0.4 PHASE C 0.3 0.2 PHASE B 0 -0.1 -0.2 PHASE A +85C, POWER FACTOR = 1 0 -0.1 -40C, POWER FACTOR = 1 -0.2 -0.3 05905-007 -0.3 -0.4 -0.5 0.1 +25C, POWER FACTOR = 1 0.1 1 10 05905-010 0.1 0.3 PHASE A + B + C % ERROR % ERROR 0.2 -0.4 -0.5 0.1 100 1 10 100 CURRENT CHANNEL (% of Full Scale) CURRENT CHANNEL (% of Full Scale) Figure 4. Error As a Percent of Reading with Internal Reference (Wye Connection) Figure 7. Error As a Percent of Reading over Temperature with External Reference (Wye Connection) 1.0 1.0 0.8 0.5 -40C, POWER FACTOR = 0.5 % ERROR % ERROR 0.6 0.4 0.2 +25C, POWER FACTOR = 1 0 POWER FACTOR = 1 POWER FACTOR = 0.5 -0.5 0 1 10 05905-008 +85C, POWER FACTOR = 0.5 -0.4 0.1 05905-011 -1.0 +25C, POWER FACTOR = 0.5 -0.2 -1.5 45 100 50 0.4 0.4 0.2 0.2 0.1 % ERROR 0.3 +25C, POWER FACTOR = 1 -0.2 -0.5 4.75V 0 5.25V 1 10 05905-012 -0.3 -0.8 -1.0 0.1 5V -0.1 -0.2 +85C, POWER FACTOR = 1 05905-009 % ERROR -40C, POWER FACTOR = 1 0.6 -0.4 65 0.5 1.0 0 60 Figure 8. Error As a Percent of Reading over Frequency with an Internal Reference (Wye Connection) Figure 5. Error As a Percent of Reading over Power Factor with Internal Reference (Wye Connection) 0.8 55 LINE FREQUENCY (Hz) CURRENT CHANNEL (% of Full Scale) -0.4 -0.5 0.1 100 1 10 CURRENT CHANNEL (% of Full Scale) CURRENT CHANNEL (% of Full Scale) Figure 9. Error As a Percent of Reading over Power Supply with Internal Reference (Wye Connection) Figure 6. Error As a Percent of Reading over Temperature with Internal Reference (Wye Connection) Rev. 0 | Page 8 of 24 100 ADE7752B TERMINOLOGY Measurement Error The error associated with the energy measurement made by the ADE7752B is defined by the following formula: Percentage Error = Energy Registered by ADE7762 - True Energy x 100% (1) True Energy Error Between Channels The high-pass filter (HPF) in the current channel has a phase lead response. To offset this phase response and equalize the phase response between channels, a phase correction network is placed in the current channel. The phase correction network ensures a phase match between the current channels and the voltage channels to within 0.1 over a range of 45 Hz to 65 Hz and 0.2 over a range of 40 Hz to 1 kHz (see Figure 21 and Figure 22). ADC Offset Error This refers to the dc offset associated with the analog inputs to the ADCs. It means that with the analog inputs connected to AGND, the ADCs still see an analog input signal offset. However, because the HPF is always present, the offset is removed from the current channel and the power calculation is not affected by this offset. Gain Error The gain error of the ADE7752B is defined as the difference between the measured output frequency (minus the offset) and the ideal output frequency. The difference is expressed as a percentage of the ideal frequency. The ideal frequency is obtained from the ADE7752B transfer function (see the Transfer Function section). Power Supply Rejection (PSR) This quantifies the ADE7752B measurement error as a percentage of reading when the power supplies are varied. For the ac PSR measurement, a reading at a nominal supply (5 V) is taken. A 200 mV rms/100 Hz signal is then introduced onto the supply and a second reading is obtained under the same input signal levels. Any error introduced is expressed as a percentage of reading. See the definition for Measurement Error. For the dc PSR measurement, a reading at nominal supplies (5 V) is taken. The supply is then varied 5% and a second reading is obtained with the same input signal levels. Any error introduced is again expressed as a percentage of reading. Rev. 0 | Page 9 of 24 ADE7752B TEST CIRCUIT VDD 100nF 3 1k Rb 5 ADE7752B IAN SAME AS IAP, IAN 1M 220V AC 1k 33nF 3 IBP 8 IBN 9 ICP 10 ICN SCF 18 16 VAP REFIN/OUT 12 15 VBP SAME AS VAP 14 VCP 13 VN TO FREQUENCY COUNTER K8 10MHz 7 SAME AS VAP 33nF 2 CLKOUT 20 CLKIN 19 S0 21 S1 22pF 22 REVP 4 1k 4 820 22pF 33nF SAME AS IAP, IAN 1 F2 23 CF 1 6 K7 ABS F1 24 IAP 33nF 1k 17 VDD 1k 0.1F VDD 10F AGND DGND 11 2 Figure 10. Test Circuit for Performance Curves Rev. 0 | Page 10 of 24 05905-015 10F ILOAD ADE7752B THEORY OF OPERATION The low frequency output of the ADE7752B is generated by accumulating the total active power information. This low frequency inherently means a long accumulation time between output pulses. The output frequency is therefore proportional to the average active power. This average active power information can, in turn, be accumulated (for example, by a counter) to generate active energy information. Because of its high output frequency and, therefore, shorter integration time, the CF output is proportional to the instantaneous active power. This pulse is useful for system calibration purposes that take place under steady load conditions. The six signals from the current and voltage transducers are digitized with ADCs. These ADCs are 16-bit, second-order - with an oversampling rate of 833 kHz. This analog input structure greatly simplifies transducer interface by providing a wide dynamic range and bipolar input for direct connection to the transducer. High-pass filters in the current channels remove the dc component from the current signals. This eliminates any inaccuracies in the active power calculation due to offsets in the voltage or current signals (see the HPF and Offset Effects section). The active power calculation is derived from the instantaneous power signal. The instantaneous power signal is generated by a direct multiplication of the current and voltage signals of each phase. To extract the active power component, the dc component, the instantaneous power signal is low-pass filtered on each phase. Figure 11 illustrates the instantaneous active power signal and shows how the active power information can be extracted by low-pass filtering the instantaneous power signal. This method is used to extract the active power information on each phase of the polyphase system. The total active power information is then obtained by adding the individual phase active power. This scheme correctly calculates active power for nonsinusoidal current and voltage waveforms at all power factors. All signal processing is carried out in the digital domain for superior stability over temperature and time. POWER FACTOR CONSIDERATIONS Low-pass filtering, the method used to extract the active power information from the individual instantaneous power signal, is still valid when the voltage and current signals of each phase are not in phase. Figure 12 displays the unity power factor condition and a displacement power factor (DPF) = 0.5, that is, current signal lagging the voltage by 60, for one phase of the polyphase. Assuming that the voltage and current waveforms are sinusoidal, the active power component of the instantaneous power signal (the dc term) is given by V x 1 x cos(60) 2 (2) This is the correct active power calculation. p(t) = i(t) x v(t) WHERE: v(t) = V x cos (t) i(t) = I x cos (t) p(t) = V x I {1+ cos (2t)} 2 VxI VxI 2 TIME VxI 2 INSTANTANEOUS POWER SIGNAL - p(t) INSTANTANEOUS VA x IA + VB x IB + ACTIVE POWER SIGNAL VC x IC 2 HPF IAP IAN ADC ABS LPF |X| MULTIPLIER VAP ADC DIGITAL-TO-FREQUENCY F1 F2 HPF IBP IBN ADC LPF |X| MULTIPLIER VBP INSTANTANEOUS TOTAL POWER SIGNAL DIGITAL-TO-FREQUENCY ADC CF HPF ADC MULTIPLIER VCP VN LPF |X| 05905-016 ICP ICN ADC Figure 11. Signal Processing Block Diagram Rev. 0 | Page 11 of 24 ADE7752B INSTANTANEOUS POWER SIGNAL i (t ) = I O + 2 x In x sin (nt n ) INSTANTANEOUS ACTIVE POWER SIGNAL (4) n =1 where: i(t) is the instantaneous current. IO is the dc component. In is the rms value of current harmonic n. n is the phase angle of the current harmonic. Vx I 2 0V CURRENT VOLTAGE INSTANTANEOUS POWER SIGNAL Using Equation 3 and Equation 4, the active power, P, can be expressed in terms of its fundamental active power (P1) and harmonic active power (PH). INSTANTANEOUS ACTIVE POWER SIGNAL P = P 1 + PH Vx I x cos(60) 2 where: 0V P1 = V 1 x I1 cos 1 60 05905-017 VOLTAGE 1 = 1 - 1 CURRENT PH = Vn x I n cos n Figure 12. DC Component of Instantaneous Power Signal n =1 NONSINUSOIDAL VOLTAGE AND CURRENT n =0 where: v(t) is the instantaneous voltage. VO is the average value. Vn is the rms value of voltage harmonic n. n is the phase angle of the voltage harmonic. (6) n = n - n The active power calculation method also holds true for nonsinusoidal current and voltage waveforms. All voltage and current waveforms in practical applications have some harmonic content. Using the Fourier transform, instantaneous voltage and current waveforms can be expressed in terms of their harmonic content v(t ) = VO + 2 x Vn x sin(nt + n ) (5) (3) As can be seen from Equation 6, a harmonic active power component is generated for every harmonic, provided that harmonic is present in both the voltage and current waveforms. The power factor calculation has been shown to be accurate in the case of a pure sinusoid. Therefore, the harmonic active power also correctly accounts for power factor because harmonics are made up of a series of pure sinusoids. A limiting factor on harmonic measurement is the bandwidth. On the ADE7752B, the bandwidth of the active power measurement is 14 kHz with a master clock frequency of 10 MHz. Rev. 0 | Page 12 of 24 ADE7752B ANALOG INPUTS CURRENT CHANNELS VOLTAGE CHANNELS The voltage outputs from the current transducers are connected to the ADE7752B current channels, which are fully differential voltage inputs. IAP, IBP, and ICP are the positive inputs for IAN, IBN, and ICN, respectively. The output of the line voltage transducer is connected to the voltage inputs of the ADE7752B. Voltage channels are pseudodifferential voltage inputs. VAP, VBP, and VCP are the positive inputs with respect to VN. The maximum peak differential signal on the current channel should be less than 500 mV (353 mV rms for a pure sinusoidal signal) for the specified operation. The maximum peak differential signal on the voltage channel is 500 mV (353 mV rms for a pure sinusoidal signal) for specified operation. Figure 14 illustrates the maximum signal levels that can be connected to the ADE7752B voltage channels. IAP-IAN +500mV VAP-VN IAP DIFFERENTIAL INPUT 500mV MAX PEAK IA +500mV IAN VAP VCM AGND Figure 13. Maximum Signal Levels, Current Channel The maximum signal levels on IAP and IAN are shown in Figure 13. The maximum differential voltage between IAP and IAN is 500 mV. The differential voltage signal on the inputs must be referenced to a common mode, for example, AGND. The maximum common-mode signal shown in Figure 13 is 25 mV. DIFFERENTIAL INPUT 500mV MAX PEAK VA VN VCM COMMON-MODE 25mV MAX -500mV VCM AGND 05905-019 -500mV VCM 05905-018 COMMON-MODE 25mV MAX Figure 14. Maximum Signal Levels, Voltage Channel Voltage channels must be driven from a common-mode voltage, that is, the differential voltage signal on the input must be referenced to a common mode (usually AGND). The analog inputs of the ADE7752B can be driven with common-mode voltages of up to 25 mV with respect to AGND. However, best results are achieved using a common mode equal to AGND. Rev. 0 | Page 13 of 24 ADE7752B TYPICAL CONNECTION DIAGRAMS CURRENT CHANNEL CONNECTION METER CONNECTIONS Figure 15 shows a typical connection diagram for the current channel (IA). A current transformer (CT) is the current transducer selected for this example. Notice that the common-mode voltage for the current channel is AGND and is derived by center-tapping the burden resistor to AGND. This provides the complementary analog input signals for IAP and IAN. The CT turns ratio and burden resistor Rb are selected to give a peak differential voltage of 500 mV at maximum load. In 3-phase service, two main power distribution services exist: 3-phase, 4-wire or 3-phase, 3-wire. The additional wire in the 3-phase, 4-wire arrangement is the neutral wire. The voltage lines have a phase difference of 120 (2/3 radians) between each other (see Equation 7). In theory, it is better to center tap Rb; however, this requires very careful attention to the layout and matching of the resistors to ensure that the channels have the same resistance. A single resistor may be more practical and is a valid design choice. Rf Rb 500mV Rf IP Cf 2 VB (t ) = 2 x VB x cos lt + 3 IAP where VA, VB, and VC represent the voltage rms values of the different phases. IAN The current inputs are represented by Cf PHASE NEUTRAL I A (t ) = 2 I A x cos (lt + A ) 2 I B (t ) = 2 I B x cos lt + + B 3 Figure 15. Typical Connection for Current Channels Rf PT Cf 500mV where: IA, IB, and IC represent the rms value of the current of each phase. A, B, and C represent the phase difference of the current and voltage channel of each phase. The instantaneous powers can then be calculated as follows: PA(t) = VA(t) x IA(t) PB(t) = VB(t) x IB(t) PC(t) = VC(t) x IC(t) Then: VAP PA (t ) = V A x I A x cos( A ) - V A x I A x cos (2l t + A ) VN PB (t ) = Rf AGND 4 + B V B x I B x cos( B ) - V B x I B x cos 2 l t + 3 Cf PHASE NEUTRAL Rb* VAP 500mV VN Rf Cf PHASE NEUTRAL *Ra >> Rf + VR; *Rb + VR = Rf Figure 16. Typical Connections for Voltage Channels 05905-021 VR* (9) 8 PC (t ) = VC x I C x cos( C ) - VC x I C x cos 2l t + + C 3 Cf Ra* (8) 4 I C (t ) = 2 I C x cos lt + + C 3 VOLTAGE CHANNEL CONNECTION Figure 16 shows two typical connections for the voltage channel. The first option uses a potential transformer (PT) to provide complete isolation from the main voltage. In the second option, the ADE7752B is biased around the neutral wire, and a resistor divider is used to provide a voltage signal proportional to the line voltage. Adjusting the ratio of Ra, Rb, and VR is a convenient way of carrying out a gain calibration on the meter. VR can be implemented using either a potentiometer or a binary weighted series of resistors. Either configuration works, however, the potentiometer is subject to noise over time. Two fixed value resistors can be used in place of VR to minimize the noise. (7) 4 V C (t ) = 2 x VC x cos lt + 3 05905-020 CT VA (t ) = 2 x VA x cos (lt ) As shown in Equation 9, the active power calculation per phase is made when current and voltage inputs of one phase are connected to the same channel (A, B, or C). Then the summation of each individual active power calculation gives the total active power information, P(t) = PA(t) + PB(t) + PC(t). Rev. 0 | Page 14 of 24 ADE7752B Figure 18 shows the connections of the ADE7752B analog inputs with the power lines in a 3-phase, 4-wire Wye service. Figure 17 shows the connections of the ADE7752B analog inputs with the power lines in a 3-phase, 3-wire delta service. Ra* Cf Ra* Rb* Rb* VR* VR* VAP Cf VAP IAP IAP ANTIALIASING FILTERS CT IAN Rb* IAN Rb* ANTIALIASING FILTERS CT CT PHASE A PHASE A PHASE C SOURCE SOURCE Rf VN Cf PHASE C Rb* ANTIALIASING FILTERS IBP IBN VBP VR* Rb* ANTIALIASING FILTERS Ra* IBP IBN Rb* VBP VR* *Ra >> Rf + VR; *Rb + VR = Rf Cf Rb* ANTIALIASING FILTERS Rb* LOAD ICN VCP VR* Rf ICP VN CF Figure 17. 3-Phase, 3-Wire Meter Connection with ADE7752B *Ra >> Rf + VR; *Rb + VR = Rf Note that only two current inputs and two voltage inputs of the ADE7752B are used in this case. The active power calculated by the ADE7752B does not depend on the selected channels. Rev. 0 | Page 15 of 24 Figure 18. 3-Phase, 4-Wire Meter Connection with ADE7752B 05905-023 Cf Cf CT 05905-022 Ra* Ra* Rb* LOAD CT PHASE B PHASE B ADE7752B POWER SUPPLY MONITOR VDD 5V 4V VREF 2.4V 1.9V 0V INTERNAL INACTIVE RESET The power supply and decoupling for the part should be such that the ripple at VDD does not exceed 5% as specified for normal operation. Rev. 0 | Page 16 of 24 ACTIVE INACTIVE Figure 19. On-Chip Power Supply Monitor 05905-024 The ADE7752B contains an on-chip power supply monitor. The power supply (VDD) is monitored continuously. At power-up, when the supply is less than 4 V 2% and VREF is less than 1.9 V (typical), the outputs of the ADE7752B are inactive and the data path is held in reset. Once VDD is greater than 4 V 2% and VREF is greater than 1.9 V (typical), the chip is active and energy accumulation begins. At power-down, when VDD falls below 4 V or VREF falls below 1.9 V (typical), the data path is again held in reset. This implementation ensures correct device operation at power-up and at power-down. The power supply monitor has built-in hysteresis and filtering. This gives a high degree of immunity to false triggering due to noisy supplies. ADE7752B HPF AND OFFSET EFFECTS The ADE7752B is phase compensated up to 1 kHz as shown. This ensures correct active harmonic power calculation even at low power factors. 0.07 0.06 0.05 PHASE (Degrees) Figure 20 shows the effect of offsets on the active power calculation. An offset on the current channel and the voltage channel contributes a dc component after multiplication, as shown in Figure 20. Because this dc component is extracted by the LPF and is used to generate the active power information for each phase, the offsets can contribute a constant error to the total active power calculation. The HPF in the current channels avoids this problem easily. By removing the offset from at least one channel, no error component can be generated at dc by the multiplication. Error terms at cos(t) are removed by the LPF and the digital-to-frequency conversion (see the Digital-toFrequency Conversion section). {V cos(t ) + VOS }x {I cos(t ) + IOS } = + 2 0.02 0.01 0 + VOS x IOS + VOS x I cos(t ) + I OS x V cos(t ) (10) 2 VxI 0.03 -0.01 x cos(2t ) 05905-031 VxI 0.04 0 100 200 300 400 500 600 700 FREQUENCY (Hz) 800 900 1000 Figure 21. Phase Error Between Channels (0 Hz to 1 kHz) 0.010 DC COMPONENT (INCLUDING ERROR TERM) IS EXTRACTED BY THE LPF FOR REAL POWER CALCULATION VOS x IOS 0.008 Vx I 2 PHASE (Degrees) 0.006 IOS x V VOS x I 0.002 0 2 FREQUENCY (RAD/sec) -0.002 05905-032 05905-026 0 0.004 Figure 20. Effect of Channel Offset on the Active Power Calculation The HPF in the current channels has an associated phase response that is compensated for on-chip. Figure 21 and Figure 22 show the phase error between channels with the compensation network. Rev. 0 | Page 17 of 24 -0.004 40 45 50 55 60 FREQUENCY (Hz) 65 Figure 22. Phase Error Between Channels (40 Hz to 70 Hz) 70 ADE7752B DIGITAL-TO-FREQUENCY CONVERSION After multiplication, the digital output of the low-pass filter contains the active power information of each phase. However, because this LPF is not an ideal brick wall filter implementation, the output signal also contains attenuated components at the line frequency and its harmonics, that is, cos(ht), where h = 1, 2, 3 ... The average value of a sinusoidal signal is zero. Thus, the frequency generated by the ADE7752B is proportional to the average active power. Figure 23 shows the digital-to-frequency conversion for steady load conditions, that is, constant voltage and current. The magnitude response of the filter is given by The frequency output CF varies over time, even under steady load conditions (see Figure 23). This frequency variation is primarily due to the cos(2t) components in the instantaneous active power signal. The output frequency on CF can be up to 160x higher than the frequency on F1 and F2. The higher output frequency is generated by accumulating the instantaneous active power signal over a much shorter time, while converting it to a frequency. This shorter accumulation period means less averaging of the cos(2t) component. Therefore, some of this instantaneous power signal passes through the digital-to-frequency conversion. 1 f 1+ 8 (11) 2 where the -3 dB cutoff frequency of the low-pass filter is 8 Hz. For a line frequency of 50 Hz, this gives an attenuation of the 2 (100 Hz) component of approximately -22 dB. The dominating harmonic is twice the line frequency, that is, cos(2t), due to the instantaneous power signal. Figure 23 shows the instantaneous active power signal at the output of the CF, which still contains a significant amount of instantaneous power information, cos(2t). Where CF is used for calibration purposes, the frequency counter should average the frequency to remove the ripple and obtain a stable frequency. If CF is being used to measure energy, for example, in a microprocessor-based application, the CF output should also be averaged to calculate power. Because the outputs F1 and F2 operate at a much lower frequency, significant averaging of the instantaneous active power signal is carried out. The result is a greatly attenuated sinusoidal content and a virtually ripple-free frequency output on F1 and F2, which are used to measure energy in a stepper motor-based meter. This signal is then passed to the digital-to-frequency converter where it is integrated (accumulated) over time to produce an output frequency. This accumulation of the signal suppresses or averages out any nondc component in the instantaneous active power signal. ABS VA LPF |X| F1 IA DIGITAL-TOFREQUENCY F1 F2 VB LPF |X| IB CF VC TIME CF DIGITAL-TOFREQUENCY TIME LPF MULTIPLIER IC |X| VxI 2 LPF TO EXTRACT REAL POWER (DC TERM) cos(2t) ATTENUATED BY LPF 0 2 FREQUENCY (RAD/sec) INSTANTANEOUS REAL POWER SIGNAL (FREQUENCY DOMAIN) Figure 23. Active Power-to-Frequency Conversion Rev. 0 | Page 18 of 24 05905-029 MULTIPLIER FREQUENCY MULTIPLIER FREQUENCY |H ( f )| = ADE7752B ACCUMULATION OF 3-PHASE POWER Power Measurement Considerations Calculating and displaying power information always have some associated ripple that depends on the integration period used in the MCU to determine average power as well as the load. For example, at light loads, the output frequency can be 10 Hz. With an integration period of 2 seconds, only about 20 pulses are counted. The possibility of missing one pulse always exists because the ADE7752B output frequency is running asynchronously to the MCU timer. This results in a 1-in-20 or 5% error in the power measurement. To remedy this, an appropriate integration time should be considered to achieve the desired accuracy. Mode Selection of the Sum of the Three Active Energies The ADE7752B can be configured to execute the arithmetic sum of the three active energies, Wh = WhA + WhB + WhC, or the sum of the absolute value of these energies, Wh = |WhA| + |WhB| + |WhC|. The selection between the two modes can be made by setting the ABS pin. Logic high and logic low applied on the ABS pin correspond to the arithmetic sum and the sum of absolute values, respectively. When the sum of the absolute values is selected, the active energy from each phase is always counted positive in the total active energy. It is particularly useful in 3-phase, 4-wire installa- tion where the sign of the active power should always be the same. If the meter is misconnected to the power lines, that is, if CT is connected in the wrong direction, the total active energy recorded without this solution can be reduced by two-thirds. The sum of the absolute values assures that the active energy recorded represents the actual active energy delivered. In this mode, the reverse power pin still detects when the arithmetic sum of the active powers is negative, but energy continues to accumulate regardless of the sign. Negative Total Power Detection The ADE7752B detects when total power, calculated as the arithmetic sum of the three phases, is negative. This detection is independent of the mode of sum of the three powers (arithmetic or absolute). This mechanism can detect an incorrect connection of the meter or generation of negative active energy. When the sum of the powers of the three phases is negative, the REVP pin output goes active high. When the sum of the powers of the three phases is positive, the REVP pin output is reset to low. The REVP pin output changes state at the same time as a pulse is issued on CF. If the sum of the powers of the three phases is negative, then the REVP pin output stays high until the sum is positive or all three phases are below the no-load threshold. Rev. 0 | Page 19 of 24 ADE7752B TRANSFER FUNCTION FREQUENCY OUTPUTS F1 AND F2 Example 1 The ADE7752B calculates the product of six voltage signals (on current channel and voltage channel) and then low-pass filters this product to extract active power information. This active power information is then converted to a frequency. The frequency information is output on F1 and F2 in the form of active high pulses. The pulse rate at these outputs is relatively low, for example, 2.09 Hz maximum for ac signals with SCF = S0 = 0; S1 = 1 (see Table 6). This means that the frequency at these outputs is generated from active power information accumulated over a relatively long period. The result is an output frequency that is proportional to the average active power. The averaging of the active power signal is implicit to the digital-to-frequency conversion. The output frequency or pulse rate is related to the input voltage signals by the following equation: In this example, with ac voltages of 500 mV peak applied to the voltage channels and current channels, the expected output frequency is calculated as follows: Freq = 6.181 x (V AN x I A + VBN x I B + VCN x I C ) x f 1 to 7 VREF 2 where: Freq is the output frequency on F1 and F2 (Hz). VAN, VBN, and VCN are the differential rms voltage signals on voltage channels (V). IA, IB, and IC are the differential rms voltage signals on current channels (V). VREF is the reference voltage (2.4 V 8%) (V). f1 to 7 is one of seven possible frequencies selected by using the logic inputs SCF, S0, and S1 (see Table 5). (12) f 1to 7 = 0.56 Hz, SCF = S0 = S1 = 1 V AN = V BN = VCN = IA = IB = IC VREF 1 S1 0 S0 0 f1 to 7 (Hz) 2.24 1 0 0 4.49 0 0 1 1.12 1 0 1 4.49 0 1 0 5.09 1 1 0 1.12 0 1 1 0.56 1 1 1 0.56 (13) Note that if the on-chip reference is used, actual output frequencies can vary from device to device due to reference tolerance of 8%. Freq = 3 x 6.313 x 0.5 x 0.5 x 0.58 2 x 2 x 2. 4 2 = 0.230 Hz (14) As can be seen from these two example calculations, the maximum output frequency for ac inputs is always half of that for dc input signals. The maximum frequency also depends on the number of phases connected to the ADE7752B. In a 3-phase, 3-wire delta service, the maximum output frequency is different from the maximum output frequency in a 3-phase, 4-wire Wye service. The reason is that there are only two phases connected to the analog inputs, but also that in a delta service, the current channel input and voltage channel input of the same phase are not in phase in normal operation. Table 5. f1 to 7 Frequency Selection1 SCF 0 0.5 V rms 2 = 2.4 V (nominal reference value ) = 500 mV peak ac = f1 to 7 is a fraction of the master clock and therefore varies if the specified CLKIN frequency is altered. Rev. 0 | Page 20 of 24 ADE7752B Example 2 f 1to 7 = 0.56 Hz, SCF = S0 = S1 = 1 In this example, the ADE7752B is connected to a 3-phase, 3-wire delta service as shown in Figure 17. The total active energy calculation processed in the ADE7752B can be expressed as V AN = V BN = I A = I B = I C = 500 mV peak ac = VCN Total Active Power = (VA - VC) x IA + (VB - VC) x IB With respect to the voltage and current inputs in Equation 7 and Equation 8, the total active power (P) is (I AP 4 P = 2 x V A x cos (l t ) - 2 x VC x cos l t + x 3 2 x I A x cos ( l t ) + For simplification, assume that A = B = C = 0 and VA = VB = VC = V. The preceding equation becomes (16) (17) where: VAN = V x sin(2/3) VBN = V x sin(/3) As the LPF on each channel eliminates the 2l component of the equation, the active power measured by the ADE7752B is P = V AN 6.313 x 0.5 x 0.5 x 0.56 3 x = 0.133 Hz 2 x 2 x 2.4 2 2 (20) SCF 0 1 0 1 0 1 0 1 S1 0 0 0 0 1 1 1 1 S0 0 1 1 1 0 0 1 1 Maximum Frequency for AC Inputs (Hz) 0.92 1.84 0.46 1.84 2.09 0.46 0.23 0.23 FREQUENCY OUTPUT CF P then becomes 3 3 xIA x + V BN x I B x 2 2 Freq = 2 x Table 6. Maximum Output Frequency on F1 and F2 2 4 2 x V B x cos l t + - v 2 x VC x cos l t + x 3 3 2 2 x I B x cos l t + 3 (15) 2 2 P = V AN x I A x sin + sin 2l t + + 3 3 V BN x I B x sin + sin 2l t + 3 3 Note that if the on-chip reference is used, actual output frequencies can vary from device to device due to a reference tolerance of 8%. Table 6 shows a complete listing of all maximum output frequencies when using all three channel inputs. - I AN ) + (VB - VC )x (I BP - I BN ) 2 2 P = 2 x V x I A x sin x sin l t + x cos(l t ) + 3 3 2 2 x V x I B x sin x sin( l t + ) x cos l t + 3 3 (19) VREF = 2.4 V nominal reference value where: VA, VB, and VC represent the voltage on Phase A, Phase B, and Phase C, respectively. IA and IB represent the current on Phase A and Phase B, respectively. P = (V A - VC ) 0.5 V rms 2 = IC = 0 (18) If full-scale ac voltage of 500 mV peak is applied to the voltage channels and current channels, the expected output frequency is calculated as follows: The pulse output calibration frequency (CF) is intended for use during calibration. The output pulse rate on CF can be up to 64x the pulse rate on F1 and F2. Table 7 shows how the two frequencies are related, depending on the states of the logic inputs S0, S1, and SCF. Because of its relatively high pulse rate, the frequency at this logic output is proportional to the instantaneous active power. As is the case with F1 and F2, the frequency is derived from the output of the low-pass filter after multiplication. However, because the output frequency is high, this active power information is accumulated over a much shorter time. Thus, less averaging is carried out in the digital-to-frequency conversion. The CF output is much more responsive to power fluctuations with much less averaging of the active power signal (see Figure 11). Table 7. Maximum Output Frequency on CF SCF 0 1 0 1 0 1 0 1 Rev. 0 | Page 21 of 24 S1 0 0 0 0 1 1 1 1 S0 0 0 1 1 0 0 1 1 f1 to 7 (Hz) 2.24 4.49 1.12 4.49 5.09 1.12 0.56 0.56 CF Maximum for AC Signals (Hz) 16 x F1, F2 = 14.76 8 x F1, F2 = 14.76 32 x F1, F2 = 14.76 16 x F1, F2 = 29.51 160 x F1, F2 = 334 16 x F1, F2 = 7.38 32 x F1, F2 = 7.38 16 x F1, F2 = 3.69 ADE7752B SELECTING A FREQUENCY FOR AN ENERGY METER APPLICATION As shown in Table 5, the user can select one of seven frequencies. This frequency selection determines the maximum frequency on F1 and F2. These outputs are intended to be used to drive the energy register (electromechanical or other). Because seven different output frequencies can be selected, the available frequency selection has been optimized for a 3-phase, 4-wire service with a meter constant of 100 imp/kWhr and a maximum current of between 10 A and 100 A. Table 8 shows the output frequency for several maximum currents (IMAX) with a line voltage of 220 V (phase neutral). In all cases, the meter constant is 100 imp/kWhr. When selecting a suitable f1 to 7 frequency for a meter design, the frequency output at IMAX (maximum load) with a 100 imp/kWhr meter constant should be compared with Column 5 of Table 9. The frequency that is closest in Table 9 determines the best choice of frequency (f1 to 7). For example, if a 3-phase, 4-wire Wye meter with a 25 A maximum current is being designed, the output frequency on F1 and F2 with a 100 imp/kWhr meter constant is 0.46 Hz at 25 A and 220 V (see Table 8). Looking at Table 9, the closest frequency to 0.46 Hz in Column 5 is 0.46 Hz. Therefore, f1 to 7 = 4.49 Hz is selected for this design. Table 8. F1 and F2 Frequency at 100 imp/kWhr Figure 2 shows a timing diagram for the various frequency outputs. The outputs F1 and F2 are the low frequency outputs that can be used to directly drive a stepper motor or electromechanical impulse counter. The F1 and F2 outputs provide two alternating high going pulses. The pulse width (t1) is set at 120 ms, and the time between the rising edges of F1 and F2 (t3) is approximately half the period of F1 (t2). If, however, the period of F1 and F2 falls below 550 ms (1.81 Hz), the pulse width of F1 and F2 is set to half of their period. The maximum output frequencies for F1 and F2 are shown in Table 6. IMAX (A) 10 25 40 60 80 100 F1 and F2 (Hz) 0.18 0.46 0.73 1.10 1.47 1.83 The f1 to 7 frequencies allow complete coverage of this range of output frequencies on F1 and F2. When designing an energy meter, the nominal design voltage on the voltage channels should be set to half scale to allow for calibration of the meter constant. The current channel should also be no more than half scale when the meter sees maximum load. This allows overcurrent signals and signals with high crest factors to be accommodated. Table 9 shows the output frequency on F1 and F2 when all six analog inputs are half scale. FREQUENCY OUTPUTS The high frequency CF output is intended to be used for communications and calibration purposes. CF produces a 90 ms-wide active high pulse (t4) at a frequency proportional to active power. The CF output frequencies are given in Table 7. As in the case of F1 and F2, if the period of CF (t5) falls below 190 ms, the CF pulse width is set to half the period. For example, if the CF frequency is 20 Hz, the CF pulse width is 25 ms. Table 9. F1 and F2 Frequency with Half-Scale AC Inputs SCF 0 1 0 1 0 1 0 1 S1 0 0 0 0 1 1 1 1 S0 0 0 1 1 0 0 1 1 f1 to 7 (Hz) 2.24 4.49 1.12 4.49 5.09 1.12 0.56 0.56 Frequency on F1 and F2 (Half-Scale AC Inputs) (Hz) 0.23 0.46 0.12 0.46 0.52 0.12 0.06 0.06 Rev. 0 | Page 22 of 24 ADE7752B NO-LOAD THRESHOLD The ADE7752B includes an innovative no-load threshold detection scheme that detects if a current input, when multiplied with any of the three voltages inputs, cannot create power larger than a noload threshold. This threshold represents 0.0075% of the fullscale output frequency. For example, if the A, B and C voltage phases are 50% of fullscale input and 120 apart, and Current Phase A is 10% of full scale with a PF = 0, this detection scheme detects that VA x IA is below the no-load threshold but that VB x IA and VC x IA are not. Therefore, the ADE7752B does not detect a no-load threshold for VA x IA and lets this phase contribute to the total power. However, in the same voltage conditions, if current Phase A is 0.0075% of full scale with a PF = 1, this detection scheme detects that VA x IA is below the no-load threshold and because VB x IA and VC x IA are as well, VA x IA is detected as below the no-load threshold and its contribution to the total power is stopped. The no-load threshold is given as 0.0075% of the full-scale output frequency for each of the f1 to 7 frequencies (see Table 10). For example, for an energy meter with a 100 imp/kWhr meter constant using f1 to 7 (4.49 Hz), the minimum output frequency at F1 or F2 is 1.38 x 10-4 Hz. This is 2.21 x 10-3 Hz at CF (16 x F1 Hz). In this example, the no-load threshold is equivalent to 4.8 W of load, or a start-up current of 20.7 mA at 240 V. Table 10. CF, F1, and F2 Minimum Frequency at No-Load Threshold SCF 0 1 0 1 0 1 0 1 Rev. 0 | Page 23 of 24 S1 0 0 0 0 1 1 1 1 S0 0 0 1 1 0 0 1 1 F1, F2 Minimum (Hz) 6.92E - 05 1.38E - 04 3.46E - 05 1.38E - 04 1.57E - 04 3.46E - 05 1.73E - 05 1.753 - 05 CF Minimum (Hz) 1.11E - 03 1.11E - 03 1.11E - 03 2.21E - 03 2.51E - 02 5.53E - 04 5.53E - 04 2.77E - 04 ADE7752B OUTLINE DIMENSIONS 15.60 (0.6142) 15.20 (0.5984) 13 24 7.60 (0.2992) 7.40 (0.2913) 12 2.65 (0.1043) 2.35 (0.0925) 0.30 (0.0118) 0.10 (0.0039) COPLANARITY 0.10 10.65 (0.4193) 10.00 (0.3937) 1.27 (0.0500) BSC 0.51 (0.0201) 0.31 (0.0122) SEATING PLANE 0.75 (0.0295) 0.25 (0.0098) 45 8 0 0.33 (0.0130) 0.20 (0.0079) 1.27 (0.0500) 0.40 (0.0157) COMPLIANT TO JEDEC STANDARDS MS-013-AD CONTROLLING DIMENSIONS ARE IN MILLIMETERS; INCH DIMENSIONS (IN PARENTHESES) ARE ROUNDED-OFF MILLIMETER EQUIVALENTS FOR REFERENCE ONLY AND ARE NOT APPROPRIATE FOR USE IN DESIGN. 060706-A 1 Figure 24. 24-Lead Standard Small Outline Package [SOIC_W] Wide Body (RW-24) Dimensions shown in millimeters and (inches) ORDERING GUIDE Model ADE7752BARWZ1 ADE7752BARWZ-RL1 1 Temperature Range -40C to +85C -40C to +85C Package Description 24-Lead Standard Small Outline Package [SOIC_W] 24-Lead [SOIC_W], on 13" Reel Z = RoHS Compliant Part. (c)2007 Analog Devices, Inc. All rights reserved. Trademarks and registered trademarks are the property of their respective owners. D05905-0-8/07(0) Rev. 0 | Page 24 of 24 Package Option RW-24 RW-24