Surge Protection Module LED Lighting Surge Protection Module > LSP05 LSP05 Module Series RoHS Description The Littelfuse LSP05 thermally protected Surge Protective Device is a self-protected device which is specially designed to be used in outdoor and commercial LED lighting fixtures for transient overvoltage protection. It is constructed with Littelfuse thermally protected varistor technology. Its built-in thermal disconnect function provides additional protection to prevent catastrophic failure and fire hazard even under the extreme circumstances of varistor end-of-life or sustaining over voltage conditions. The LSP05 facilitates customer's product compliance to IEEE C62.41.2 Location Category C Low and US Dept of Energy MSSLC Model Spec. Agency Approvals Standard Agency File Number UL1449 E320116 Applications * Outdoor and Commercial LED Lighting * Roadway lighting * Traffic lighting * Digital signage * * * * * Wash wall lighting Parking garage/lot lighting Flood lighting Tunnel lighting Street lighting Additional Information Datasheet Resources Samples * Maximum Discharge Current, 10kA, 8/20us * Meets ANSI C82.775-2015: Location Category CM, 10kV/5kA, 1.2/50S-8/20S Combination Wave. * Meets IEEE C62.41.2: Location Category CLow, 6kV/3kA, 1.2/50S-8/20S Combination Wave. * Meets US Dept. of Energy MSSLC Model Spec. * Parallel connected SPD device * Thermally protected Varistor technology * IP66 Water-proof and Dust-proof * Indication wire lead options for Parallel connected modules * UL 1449 Type 4 Component Assembly Recognition (Type 4CA) * IEC61643-11 Class II/ EN61643-11 Type 2 Compliant1 * Compact form factor (48x48x30mm) with mounting tabs * 240Vac and 277Vac voltage ratings are available for Class I and Class II installation based on IEC luminaire protection classes * CE - Meets the requirements of Low Voltage and RoHS European Directives. LV UltraMOVTM Series Agency Features Notes: 1. Self-declared compliance. Absolute Maximum Ratings * For ratings of individual members of a series, see Device Ratings and Specifications chart LSP05 Series Units 150 to 510 V Continous: Steady State Applied Voltage: Max AC Voltage Range (VM(AC)RMS) Transient: Maximum Discharge Current 8/20s Waveform (Imax) 10,000 A Nominal Discharge Current 8/20s Waveform (In) 5,000 A Operating Ambient Temperature Range (TA) -45 to +85 C Storage Temperature Range (TSTG) -45 to +125 C Isolation Voltage Capability (When the thermal disconnect opens) Insulation Resistance 600 V >1,000 M CAUTION: Stresses above those listed in "Absolute Maximum Ratings" may cause permanent damage to the device. This is a stress only rating and operation of the device at these or any other conditions above those indicated in the operational sections of this specification is not implied. (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 04/10/18 1 Surge Protection Module LED Lighting Surge Protection Module > LSP05 LSP05 Series Device Ratings & Specifications Operating Voltage (VAC) MCOV/Uc (VAC)5 Maximum Discharge Current (Imax)(A)2 Nominal Discharge Current (In)(A)1 LSP05120* 120 150 10,000 5,000 LSP05240* 240 275 10,000 5,000 LSP05277* 277 320 10,000 5,000 LSP05347* 347 420 10,000 5,000 LSP05480* 480 510 10,000 5,000 L-L:240 L-L:275 L-N/G:120 L-N/G:150 10,000 5,000 L-L:480 L-L:510 L-N/G:277 L-N/G:320 Part Number7 LSP05240LL* LSP05480LL* 10,000 5,000 MLV (V)3 Up (V)4 L-N:680 L-G:680 N-G:630 L-N:1100 L-G:1100 N-G:1100 L-N:1270 L-G:1270 N-G:1220 L-N:1600 L-G:1600 N-G:1580 L-N:1780 L-G:1780 N-G:1730 Safety Compliance IEC/EN 61643-116 800 UL1449 X 1200 X X 1400 X X 1700 X 1900 X L-L:1100 L-L:1200 X L-N/G:680 L-N/G:800 X L-L:1780 L-L:1900 X L-N/G:1270 L-N/G:1400 X Notes: 1. Nominal Discharge Current (In)(A): The nominal discharge current is a measure of the SPDs endurance capability; 15 impulses of discharge current uses the 8/20us current waveform. 2. Maximum Discharge Current (Imax)(A): The maximum discharge current is a measure of the SPDs maximum capability; single impulse of discharge current uses the 8/20us current waveform. 3. MLV - UL1449 Measured limiting voltage; the highest value of residual voltage measurements during the application of impulses of 8/20us nominal discharge current (In); an average voltage value of 15 impulses 4. Up - IEC 61643-11 Voltage protection level; the highest value of residual voltage measurements during the application of impulses of 8/20us nominal discharge current (In); a rounding voltage value of maximum measurement. 5. MCOV/UC: Maximum Continuous Operating Voltage - maximum r.m.s. voltage that could be continuously applied to the SPD. 6. Part Numbers LSP05xxxPM Only. 7. * = - P or PM 8. Repetitive Surge Withstanding: 15 strikes at 5,000A (8/20us) with steady MLV/Up. Repetitive Surge Capability for LSP05 Pulse Rating (8x20Sec) Strikes Surge 1 10,000A 2 7,000A 15 5,000A 100 1,500A 1,000 700A Figure 1 2 (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 04/10/18 Surge Protection Module LED Lighting Surge Protection Module > LSP05 Typical Dimensions (mm) 56.0 0.5 Application/Installation Schematic Dimensions 48.71.5 Typical Dimensions (mm) 2x o4.80.2 56.0 0.5 100 20 100 20 49.01.5 L 3 indication wires all use the AWG22. L 32.51.0 2.3 0.2 6 2 6 2 64.0 1.5 or N/G 48.71.5 100 20 49.01.5 100 20 3 indication wires all use the AWG22. L L 32.51.0 64.0 1.5 N AC/DC Power Supply G or N/G 6 2 N With LED indicating SPD status - ON (green): SPD is online - OFF: SPD needs replacement LSP05XXXXXPM 2.3 0.2 L Parallel Connection 2x o4.80.2 LSP05XXXXXP L + - LED Module R1 R2 R3 SPD NC LED normally on LSP05xxxPM L L N N R AC/DC Power Supply G + - LED Module 6 2 R1 Parallel Connection SPD LED Normally Off R2 R3 With LED indicating SPD status LSP05xxxPM - OFF: SPD is online - ON (red): SPD needs replacement Notes: 1. LED indicator and associated circuitry are not included in the module. 2. R1 must be capped off by wire nut when not connected (NC). 3. R1 and R2 are AC line voltage (hot); R3 is AC neutral voltage. 4. R2 voltage is cut off when SPD needs replacement. 5. R is current limiting resistor; it resistance/wattage is determined by AC line voltage and desired current driving LED. Example: AC line voltage 240V, LED: 1.6mA, resistor: 150Kohm/0.5W. L L LSP05XXXXXP Notes: LSP05XXXXXPM 1. Black: Line; White: Neutral; Green: Ground (P/N with suffix X3333/X3316: Brown: Line; Blue: Neutral; Green-Yellow stripe: Ground) 2. Black: R1; Red: R2; Blue: R3 3. Wire Gauge: AWG16 wire Line in, AWG22 Wire for indication; Wire Length: 100mm or customized N/G or L L N N AC/DC Power + Supply - LED Module G Parallel Connection LV UltraMOVTM Series 3 R SPD Part Numbering System LSP 05 480LL P Xxxxx L L Littelfuse Surge Protection Module N N Nominal Discharge Current (In) Operating Voltage Connection mode G Device Family LL: for L,L,N/G Blank: L-N, L-G, N-G P or PM (P: parallel connection; PM: parallel connection and with monitor indication wire) Parallel Connection (for Class II Unearthed) AC/DC Power Supply + - LED Module SPD ~X3316 Other non-standard option: X3333: with GND wire connection, available for 240Vac and 277Vac rating with CE Marking for Class I earthed installation Wire Color: Line: Brown, Neutral: Blue, Ground/P: Green with yellow stripe 3316: without GND wire connection option Wire Color: Line: Brown, Neutral: Blue Disclaimer Notice - Information furnished is believed to be accurate and reliable. However, users should independently evaluate the 3 suitability of and test each product selected for their own applications. Littelfuse products are not designed for, and may not be used in, all applications. Read complete Disclaimer Notice at http://www.littelfuse.com/disclaimer-electronics. (c) 2018 Littelfuse, Inc. Specifications are subject to change without notice. Revised: 04/10/18 3