SPECIFICATIONS
MODEL ADA1000F-24 ADA1000F-30 ADA1000F-36 ADA1000F-48
INPUT
VOLTAGE[V] AC85 - 264 1for DC 120 - 350 (AC64 or DC90 optionally available *6)
FREQUENCY[Hz] 50/60 (47 - 63)or DC
EFFICIENCY[%]
ACIN 100V
86typ (Io=100%)86typ (Io=100%)87typ (Io=100%)87typ (Io=100%)
ACIN 200V
88typ (Io=100%)88typ (Io=100%)89typ (Io=100%)89typ (Io=100%)
POWER FACTOR
ACIN 100V
0.99typ (Io=100%)
ACIN 200V
0.98typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
*1
20typ (Io=100%)(
More than 3sec.to re-start)
ACIN 200V
*1
40typ (Io=100%)(
More than 3sec.to re-start)
LEAKAGE CURRENT[mA] 0.75max (60Hz,According to IEC60950 and DEN-AN)(
Io=100%)
OUTPUT
VOLTAGE[V] 24 30 36 48
CURRENT[A]
ACIN 100V
*2
21 (Peak 63)convection 16.5 (Peak 50)convection 14 (Peak 42)convection
10.5 (Peak 31.5)convection
ACIN 100V
*2
33 (Peak 63)forced air 26 (Peak 50)forced air 22 (Peak 42)forced air 16.5 (Peak 31.5)forced air
ACIN 200V
*2
25 (Peak 83)convection 20 (Peak 66)convection 16.5 (Peak 55)convection
11.5 (Peak 41.5)convection
ACIN 200V
*2
42 (Peak 83)forced air 33.5 (Peak 66)forced air 28 (Peak 55)forced air 21 (Peak 41.5)forced air
LINE REGULATION[mV] 96max 120max 144max 192max
LOAD REGULATION[mV] 150max 180max 240max 300max
RIPPLE[mVp-p]
0 to +50C
*3
120max 160max 200max 200max
-10 - 0C
*3
160max 230max 260max 300max
RIPPLE NOISE[mVp-p]
0 to +50C
*3
150max 190max 230max 250max
-10 - 0C
*3
180max 250max 280max 400max
TEMPERATURE REGULATION[mV]
0 to +50C
240max 300max 360max 480max
DRIFT[mV]
*4
96max 120max 144max 192max
START-UP TIME[ms] 500max (ACIN 100V,Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V,Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
21.6 - 27.0 27.0 - 33.0 33.0 - 41.0 41.0 - 52.8
OUTPUT VOLTAGE SETTING[V]
23.5 - 24.5 29.0 - 31.0 35.0 - 37.0 47 - 49
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 101% of peak current and recovers automatically
OVERVOLTAGE PROTECTION[V]
31 - 34.5 40 - 48 51 - 60 64 - 76
OPERATING INDICATION LED (Green)
ALARM OUTPUT Detecting low input voltage(PF), detecting low output voltage(LV).(Optional : -W,refer to Instruction Manual 5)
REMOTE ON/OFF(RC)Requirement for external source (Option : -R,refer to Instruction Manual 5)
ISOLATION INPUT-OUTPUT-RC
*5
AC3,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
INPUT-FG AC2,000V 1minute,Cutoff current = 10mA,DC500V 50MWmin (At Room Temperature)
OUTPUT-RC-FG
*5
AC500V 1minute,Cutoff current = 100mA,DC500V 50MWmin (At Room Temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
-10 to +71C,20 - 90%RH (Non condensing)(
Refer to DERATING CURVE), 3,000m (10,000feet)max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C,20 - 90%RH (Non condensing), 9,000m (30,000feet)max
VIBRATION 10 - 55Hz,19.6m/s2(2G), 3minutes period,60minutes each along X,Y and Z axis
IMPACT 196.1m/s2(20G), 11ms,once each X,Y and Z axis
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS
UL60950-1,C-UL(CSA60950-1), EN60950-1,EN60065,EN50178 Complies with DEN-AN and IEC60950-1 (At only AC input)
CONDUCTED NOISE Complies with FCC-B,CISPR22-B,EN55022-B,VCCI-B
HARMONIC ATTENUATOR Complies with IEC61000-3-2
OTHERS CASE SIZE/WEIGHT 75X127X280mm [2.95X5X11.02 inches] (WXHXD)(
without terminal block)/2.5kg max
COOLING METHOD Convection/Forced air
*8
*1The value is primary surge.The current of input surge to a built-in EMI/EMC Filter (0.2ms or
less) is excluded.
*2Peak loading for 10sec.And Duty 35% max.Refer to Instruction Manual 4.Forced air is shown
in Instruction Manual 2.3.
*3This is the value that measured on measuring board with capacitor of 22mF within 150mm
from output terminal.Measured by 20MHz oscilloscope or Ripple-Noise meter (Equivalent to
KEISOKU-GIKEN: RM101).
*4Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C,
with the input voltage held constant at the rated input/output.
*5Applicable when remote control (optional) is added.
*6 Derating is required.Consult us for details.
*7Please contact us about safety approvals for the model with option.
*8Please contact us about class C.
*A sound may occur from power supply at pulse loading.
ADA1000F
AC-DC Power Supplies Enclosed Type
ADA 1000 F -24 -O
Ordering information
1Series name
2Output wattage
3Universal input
4Output voltage
5Optional *7
G:Low leakage current
E :Low leakage current
and EMI class A
F :with Fan unit
T :Vertical terminal block
J :Connector type
C :with Coating
R :Remote ON/OFF
N1:DIN rail
W:Alarms and Redundant
operation
Specification is changed at
option,refer to Instruction
Manual.