321
© 2009 Littelfuse, Inc.
Specifications are subject to change without notice.
Axial Lead & Cartridge Fuses
314/324 Series
3AB > Fast Acting > 314/324 Series
Please refer to www.littelfuse.com/series/314.html
or /324.html for current information.
314/324 Series
The 3AB Fast-Acting Fuse with ceramic body construction
permits higher interrupting ratings and voltage ratings. Ideal
for applications where high current loads are expected.
Agency Approvals
Agency Agency File Number Ampere Range
E10480 125mA - 15A
LR 29862 125mA - 20A
E10480 15A* - 40A
PS
E
NBK 030805 - E10480A-F
NBK 260106 - JP1021A/B 125mA - 30A
SU05001 -
6001/6002/6003/7006 125mA - 30 A
125mA - 30A
Features
Electrical Characteristics for Series
Applications
% of Ampere
Rating Ampere Rating Opening Time
100% 125mA – 30A 4 hours, Minimum
135% 125mA – 30A 1 sec.., Maximum
200% 125mA – 12A 15 sec., Maximum
15A – 30A 30 sec., Maximum
Electrical Characteristic Specification by Item
Amp
Code
Ampere
Rating
(A)
Voltage
Rating
(V)
Interrupting
Rating
Nominal
Cold
Resistance
(Ohms)
Nominal
Melting
I
2
t (A
2
sec)
Agency Approvals
PS
E
.125 0.125 250
35A@250Vac
10KA@125Vac
10KA@125Vdc
6.20 0.00149 xx x
.250 0.25 250 1.95 0.0140 xx x
.375 0.375 250 0.820 0.050 xx x
.500 0.5 250 0.500 0.115 xx x
.750 0.75 250 0.250 0.466 xx x
001. 1 250
100A@250Vac
10KA@125Vac
10KA@125Vdc
0.189 0.690 xx xx
002. 2 250 0.0700 11.0 xx xx
003. 3 250 0.0432 14.6 x x x x x
004. 4 250
750A@250Vac
10KA@125Vac
10KA@125Vdc
0.0470 10.4 x x x x x
005. 5 250 0.0300 26.0 x x x x x
006. 6 250 0.0240 45.0 x x x x x
007. 7 250 0.0187 71.0 x x x x x
008. 8 250 0.0153 105 x x x x x
010. 10 250 0.0105 206 x x x x x
012. 12 250 0.00760 570 xx xx
015. 15 250 0.00505 292 xx xx
015.* 15 280 0.00505 292 xx
020. 20 250
1000A@250Vac
200A@300Vac
10KA@125Vac
10KA@125Vdc
0.00355 631 x x x x
020.* 20 280 0.00355 631 x x
025. 25 250
100A@250Vac
1000@75Vdc
400@125Vac
400A@125Vdc
0.00235 1450 x x x x
025.** 25 280 0.00235 1450 x x
030. 30 250 0.00182 2490 xxxx
040. 40 250
1000A@250Vac
400A@150Vdc
0.0014 22925 x x
t *OBDDPSEBODFXJUI6-
Standard 248-14
t "WBJMBCMFJODBSUSJEHF
and axial lead format
and with various
forming dimensions
t 3P)4DPNQMJBOUBOE
Lead-free
Used as supplementary protection in appliance or
utilization equipment to provide individual protection for
components or internal circuits.
314/324 Series Lead-free 3AB, Fast-acting Fuse PS
E
* 350A@280Vac interrupting rating available for 15A and 20A. ** 50A@280Vac for 25A. Add suffix ’280’. Example: 0324020.MX280P.
Description
Revised: July 15, 2009