Modicon Momentum
automation platform
Catalog
2011
Modicon Momentum
automation platform
Catalog
2010
&
Global Detection
Electronic and
electromechanical sensors
MKTED208052EN
Photo-electric sensors
Proximity sensors
Capacitive proximity sensors
Ultrasonic sensors
Limit switches
Pressure switches
Rotary encoders
Radio frequency identication
Machine cabling accessories
&
Modicon Quantum
automation platform
Catalog 2009
MKTED208011EN-US
Safety PLCs
Safety CPUs
Unity Concept and
ProWORX software
&
Modicon Premium
automation platform
Catalog 2010
MKTED208054EN-US
Unity processors
PL7 processors
Communication software
&
Modicon M340
automation platform
Catalog 2010
DIA6ED2081007EN-US
PLCs
Discrete, analog I/O and
application-specic solutions
Communication
&
Modicon Momentum
automation platform
Catalog 2010
MKTED205061EN-US
&
Twido programmable
controller and TwidoSuite
software
DIA3ED2090202EN
Controller base
Discrete, analog I/O
Communication
&
Automation functions,
relays, interfaces and
power supplies
MKTED207031EN
Smart relays
Timing relays
Measurement & control relays
Analog interfaces
Counters
Plug-in relays
Interfaces for discrete signals
Power supplies & transformers
Software
PLCs and safety controllers
programming software
&
Control and signalling
components
MKTED208031EN
Control and signalling units
Control stations & enclosures
Cam switches
Beacons and indicator banks
Pendant control stations
Controllers
Emergency stops
Foot switches
&
Magelis
Human/Machine Interfaces
Catalog 2010
MKTED206071EN-US
Operator interface terminals
Industrial PCs
HMI and SCADA PC-based
software
Software
Vijeo Designer
Operator terminal software
&
Lexium 32 Servo Drives
motion control
Catalog 2009/2010
DIA7ED2090405EN-US
Motion controllers
Servo drives and Servo motors
Stepper motors and drives
Integrated drives
Modicon Premium
motion control modules
&
Soft starters and variable
speed drives
MKTED206111EN
Soft starters and variable speed
drives
Software
Software for drives
Motor control programming
software
Detection
Automation
Automation
Operator dialog
Motion and Drives
Some products shown in this catalog are not available in every country. Check individual country’s web site or Sales Ofce for product availability.
See our web site: www.schneider-electric.us/
A full range of catalogs for . . . . . .
&
Motor starter solutions
Control and protection
components
MKTED205103EN
Contactors
Circuit-breakers, fuse carriers
Thermal relays
Combinations, motor controllers
Mounting solutions
Motor starter mounting kits
This catalog contains
Automation and Control function
products relating to machines
Safety
&
Preventa
Machine Safety Products
Catalog 2009
MKTED208051EN-US
Safety PLCs
Safety controllers
Safety monitors
Safety solutions on AS-Interface
cabling system
Safety switches
Safety light curtains
Safety mats
Emergency stops
Control stations
Enabling switches
Foot switches
Beacons & indicator banks
Switch disconnectors
Thermal-magnetic motor circuit
breakers
Enclosed D.O.L. starters
Software
XPSMFWIN conguration
software
XPSMCWIN conguration
software
&
Terminal blocks
MKTED207011EN
Terminal blocks
Cable ends
&
Modicon STB
IP 20 distributed
inputs/outputs
Catalog 2010
MKTED208053EN-US
Modules for automation station
Network interfaces
Power distribution
Digital I/O, analogs and
application-specic
Software
STB conguration software
&
Phaseo power supplies
and transformers
DIA3ED2061209EN
Switch mode power supplies
Filtered rectied power supplies
Transformers
This catalog contains
Automation and Control function
products relating to
Communication
&
Machine & Installations with
industrial communication
MKTED207012EN
Preferred implementations
Ethernet TCP/IP, the universal
communication standard
CANopen for machines and
installations
AS-Interface, simple and
ASI-Safe
Products
Human-Machine interface
Controllers and PLCs
Field devices
Infrastructure and wiring
Gateways
Software and tools
Collaborative Automation
Partner Program & Partners
Motor control
Machine safety
Interfaces and I/O
Power supplies
Systems & architectures
A full range of catalogs for . . . . . . . . . . . Automation & Control functions
1
2
3
4
5
6
7
8
9
10
4
Modicon Momentum
automation platform
b Introduction ..................................................... 6
Discrete I/O bases
Selection guide ................................................... 8
b Introduction, description ........................................... 12
b Specications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
b References .................................................... 19
b Dimensions, mounting ............................................ 20
b Wiring diagrams ................................................. 20
Analog I/O bases
Selection guide .................................................. 26
b Introduction, description ........................................... 28
b Specications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
b References .................................................... 35
b Dimensions, mounting ............................................ 35
b Wiring diagrams ................................................. 36
Specialty module I/O bases
Selection guide .................................................. 38
b Introduction, description ........................................... 40
b Specications. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41
b References .................................................... 42
b Wiring diagrams ................................................. 43
Communication adapters
Selection guide .................................................. 44
b Ethernet TCP/IP network communication adapters . . . . . . . . . . . . . . . . . . . . . . 48
b Modbus Plus network communication adapters ........................ 50
b FIPIO bus communication adapters ................................. 54
b In t e r Bu s bus communication adapters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56
b Probus DP bus communication adapter ............................. 58
Contents
1
2
3
4
5
6
7
8
9
10
5
M1/M1E processor adapters and option adapters
Processor adapters selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 60
b M1/M1E processor adapters
v Introduction .................................................. 62
v Description ................................................... 63
v Specications ................................................. 64
v References .................................................. 68
Option adapters selection guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70
b Option adapters
v Introduction .................................................. 72
v Description ................................................... 73
v Specications ................................................. 74
v References .................................................. 75
Ethernet network cabling system
b Infrastructure ................................................... 76
b ConneXium connection components ................................ 78
b ConneXium hub ................................................. 80
b ConneXium transceiver ........................................... 81
b ConneXium switches ............................................. 82
Programming software (for M1/M1E processor adapters)
b Concept IEC programming software
v Introduction .................................................. 90
v Functions .................................................... 91
v References .................................................. 95
b ProWORX 32 for 984 Ladder Logic programming software
v Introduction .................................................. 96
v References .................................................. 99
Additional products and services
b Optional conformal coating for agressive environments
v Introduction ................................................. 100
v References ................................................. 101
b Enhanced grouding system
v Introduction ................................................. 102
v References ................................................. 102
b User documentation ............................................. 103
b Automation product certications ................................... 104
b Community regulations .......................................... 105
b Product reference index .......................................... 106
Advantys
, Altistart
, Altivar
, Concept
, ConneXium
, FactoryCast
, FIPIO
, FIPway
, Lexium
, Magelis
, M340
, Modbus
, Modbus Plus
,
Modicon
, Modsoft
, Momentum
, OSItrack
, Phaseo
, PowerSuite
, Premium
, Preventa
, ProWORX 32
, Quantum
, Schneider Electric
,
Telefast
, TeSys
, Transparent Ready
, TSX Micro
, Twido
, TwidoSoft
, TwidoSuite
, Unity
, Unity
Pro, Vijeo Designer
, Vijeo Look
X-Way
are trademarks or registered trademarks of Schneider Electric. Other trademarks used herein are the property of their respective owners.
1
2
3
4
5
6
7
8
9
10
6
Modicon Momentum
automation platform
A modular concept with four easy pieces
The Modicon
Momentum
I/O system is comprised of 4 fundamental components – that
easily snap together in various combinations – to form a versatile, distributed I/O system.
The four components are:
1 I/O base
2 Communication adapter
3 Processor adapter
4 Option adapter
Modicon Momentum communication adapters 2
The design of the Modicon Momentum separates the communications from the I/O
base 1, thus creating a truly open I/O system that can be easily adapted to any
eldbus network. When a Modicon Momentum I/O is coupled with a communication
adapter 2, the two form a remote I/O drop that connects directly to virtually any
standard eldbus I/O network. Together, Modicon Momentum I/O supports different
types of control systems, including: personal computers, distributed control systems,
programmable controllers and Modicon Momentum processors.
(1) The processor adapters 3 are only compatible with Concept or ProWORX software.
1 I/O base
2 Communication adapter
4 Option adapter (1)
3 Processor adapter (1)
Introduction
2 Modbus Plus communication adapter
1
2
3
4
5
6
7
8
9
10
7
Modicon Momentum
automation platform
Modicon Momentum I/O bases
A specialized Modicon Momentum I/O base supports the rest of the control system.
The communication adapter 2, processor adapter and option adapter all snap onto the
I/O base 1. A selection of I/O base modules are available, including analog I/O,
discrete I/O, multi-function analog and bi-directional discrete bases. In addition,
Modicon Momentum I/O bases offer simple plug-in terminal strips, as well as
standard 35 mm DIN rail or panel mounting, for ease of maintenance and installation.
Modicon Momentum processors adapters 3 and option adapters 4 (1)
When local distributed intelligence is required at the point of control, Modicon Momentum
has the answer. The Modicon Momentum M1 processor adapter 3 is a full edged PLC
containing a CPU, RAM and Flash memory. It is based on the popular Modicon family of
PLCs (i.e., directly compatible with Quantum, Compact and 984 PLCs), and snaps
onto the Modicon Momentum I/O base 1, just like the communication adapter 2.
The option adapter 4 provides the processor adapter with additional networking
capabilities, a time-of-day clock, and a battery back-up. The option adapter also
snaps onto the I/O base. In the gure below,the processor adapter is stacked on top.
Optional conformal coating
If your control system needs to operate in a corrosive environment, selected
Modicon Momentum modules can be ordered with a conformal coating applied to
components of the product. Conformal coating will extend product life and enhance
its environmental and performance capabilities.
See pages 100 and 101.
Enhanced grounding system
Due to new In t e r Bu s standards for electrical noise immunity, a number of Modicon
Momentum products have been updated to include an enhanced grounding system.
This system is required to meet the revised electrical noise immunity standard
(ability to pass a 2.2 kV electrical fast transient burst test).
See page 102 for a list of Modicon Momentum products that currently have been
updated to include the new grounding system.
(1) The processor adapters are only compatible with the Concept or ProWORX software.
1 I/O base
2 Communication
adapter
1 I/O base
3 Processor
adapter (1)
4 Option
adapter
Introduction (continued)
1
2
3
4
5
6
7
8
9
10
8
Modicon Momentum
automation platform
Discrete I/O bases
Product type
Input modules for direct current Input modules for alternating current
Type of signal True high
Operating voltage and Input voltage 24 Vdc 120 Vac 230 Vac
Current consumption max. 250 mA max. 125 mA
Input type IEC 1131 Type 1+ IEC 1131 Type 2 IEC 1131 Type 1+
Output voltage
Output type
Number of points 1 x 16 In 2 x 16 In 2 x 8 In
Potential isolation Point to point None None
Group to group None 1780 Vac
Field to adapter 500 Vac 1780 Vac
Current capacity Per output
Per group
Per module
Response time OFF-ON 2.2 ms 10 ms @ 60 Hz 13.3 ms @ 60 Hz
ON-OFF 3.3 ms 35 ms @ 60 Hz 13.3 ms @ 60 Hz
Protection against short circuit and overload
Fault reporting Detected output fault
Detected I/O error
Blown fuse
Type of module 170 ADI 340 00 170 ADI 350 00 170 ADI 540 50 170 ADI 740 50
Pages 17
Selection guide
1
2
3
4
5
6
7
8
9
10
9
Output modules for direct current Output modules for alternating current Relay output
module
True high
24 Vdc 120 Vac 230 Vac 120 to 230 Vdc
max. 250 mA max. 125 mA max. 65 mA 125 mA @ 120 Vac
65 mA @ 230VDC
24 Vdc 120 Vac 230 Vac 20 to 250 Vac
5 to 30 Vdc
Solid state switch Triac Relay from “C”
2 x 8 out 2 x 16 out 2 x 4 out 2 x 8 out 2 x 4 out 2 x 8 out 6 out (isolated)
None None 1780 Vac for 1 mn
None None 1780 Vac for 1 mn
500 Vac 1780 Vac 1780 Vac for 1 mn
0.5 A 0.5 A 2 A 0.5 A 2 A 0.5 A 5 A
4 A 8 A 4 A 4 A 4 A 4 A 5 A
8 A 16 A 8 A 8 A 8 A 8 A 21 A @ 60 °C
25 A @ 30 °C
< 0.1 ms max. 1/2 x 1/f 10 ms
< 0.1 ms max. 1/2 x 1/f 20 ms
Electronically safeguarded 1 fuse per group
1 LED/Out 1 LED/4 Out None
to adapter to adapter None
1 LED
170 ADO 340 00 170 ADO 350 00 170 ADO 530 50 170 ADO 540 50 170 ADO 730 50 170 ADO 740 50 170 ADO 830 30
17
1
2
3
4
5
6
7
8
9
10
10
Modicon Momentum
automation platform
Discrete I/O bases
Product type
I/O modules for direct current
Type of signal True high True low True high
Input voltage 24 Vdc
Operating voltage 24 Vdc
Current consumption max. 250 mA max. 250 mA +
sensor current
Input type IEC 1131 Type 1+
Output voltage 24 Vdc
Output type Solid state switch
Number of points 1 x 16 In, 2 x 8 Out 4 x 4 In, 2 x 4 Out
Potential isolation Point to point None
Group to group None
Field to adapter 500 Vac
Current capacity Per output 0.5 A 2 A
Per group 4 A 8 A
Per module 8 A 16 A
Response time OFF-ON 2.2 ms In, < 1 ms Out 60 ms in, < 1 ms Out 2.2 ms In, < 1 ms Out
ON-OFF 3.3 ms In, < 1 ms Out 80 ms in, < 1 ms Out 3.3 ms In, < 1 ms Out
Protection against short circuit and overload Electrically safeguarded outputs Electrically
safeguarded outputs
and 4 electronically
safeguarded sensor
supply group
Fault reporting Detected output fault 1 LED/Out
Detected I/O error to adapter
Blown fuse
Type of module 170 ADM 350 10 170 ADM 350 11 170 ADM 350 15 170 ADM 370 10
Pages 17
Selection guide (continued)
1
2
3
4
5
6
7
8
9
10
11
I/O modules for direct current I/O modules for direct and alternating current
True high
24 Vdc 12, 24, 48 Vdc 24 Vdc 120 Vac
24 Vdc 12, 24, 48 Vdc 24 Vdc 120 Vac
max. 180 mA 500 mA @ 12 Vdc
250 mA @ 24 Vdc
125 mA @ 48 Vdc
max. 250 mA max. 160 mA
IEC 1131 Type 1+, monitored IEC 1131 Type 1+ IEC 1131 Type 2
24 Vdc 12, 24, 48 Vdc 24…230 Vac or 20…115 Vdc /
24 Vdc (170 ADM 390 31 only)
120…132 Vac
Solid state switch Relay (normally open) Triac
1 x 16 In, 1x 8 Out and
1 x 4 Out
1 x 16 In, 1 x 16 Out 1 x 10 In, 2 x 4 Out 1 x 10 In, 1 x 8 Out
None None None 1780 Vac None
None None None 1780 Vac None
500 Vac 707 Vdc 500 Vac 500 Vac 1780 Vac
0.5 A 0.5 A 2 A ohmic load 0.5 A
4 A group 1, 2 A group 2 8 A ohmic load 2 A
6 A 8 A @ 50 °C, 7 A @ 60 °C 16 A ohmic load 4 A
2.2 ms In, < 1 ms Out 2.2 ms In, < 2.5 ms Out 2.2 ms In, < 10 ms Out max 1/2 x 1/f
3.3 ms In, < 1 ms Out 3.3 ms In, < 2.5 ms Out 3.3 ms In, < 10 ms Out max 1/2 x 1/f
Electronically safeguarded
outputs
Electrically safeguarded
outputs
None Varistor in parallel with each
contact
1 internal fuse per group
(not against overload)
1 LED/In, 1 LED/Out 1 LED/Out None None
to adapter to adapter None None
1 LED/fuse
170 ADM 390 10 170 ADM 850 10 170 ADM 390 30 /
170 ADM 390 91
170 ARM 370 30 170 ADM 690 51
17
1
2
3
4
5
6
7
8
9
10
12
Modicon Momentum
automation platform
Discrete I/O bases
Introduction
Modicon Momentum automation platform products are modular in design.
Communication adapters and Processor adapters are designed to work as
functional modules when they are snapped onto a Modicon Momentum I/O base.
This I/O base requires that some type of Modicon Momentum adapter be attached
before it can be functional.
I/O bases t into compact standard housings that can be mounted on a DIN rail or on
panels in a cabinet. They read information from eld sensing devices and control
discrete and analog eld actuating devices. Terminal blocks and bus bars are
available for use with the bases so that these bases can be used to support 2-, 3-,
and 4-wire eld devices.
I/O eld devices and the power supply to the module are connected via three 18-pin
terminal blocks and an optional 1-, 2-, or 3-row busbar. The terminal connectors are
electrically connected to the module, while the optional busbars are not.
Busbars provide a common connection for the eld devices and serve as protective
distribution connectors. Depending on the I/O base and the type and number of eld
devices connected to it, a 1-, 2-, or 3-row busbar may be used.
Terminal blocks and busbars are ordered separately, and are not shipped with the
Modicon Momentum I/O bases. They are available in either screw-in or spring-clip
versions.
Description
170 ADp discrete I/O base units feature the following on the front panel:
1 Internal interface connector for the communication module or processor module
2 Locking and ground contact for the communication module or processor module
3 LED status indicators (the number of indicators will depend on the number of
channels)
4 Up to three connectors for the removable terminal blocks (Modbus dependent).
5 Grounding screw
6 Slot for the power strip
7 Two screw holes for panel mounting
8 Protective cover
Connectors to be ordered separately:
b removable screw or spring terminals 170 XTS 00p 00
b 1 to 3-row screw or spring bus bar 170 XTS 00p 01
Introduction,
description
Specications:
pages 13 to 18
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
1
3
4
8
4
5
4
2
76
7
1
2
3
4
5
6
7
8
9
10
13
Modicon Momentum
automation platform
Discrete I/O bases
Specications for discrete input bases
Type of input base unit 170 ADI 340 00 170 ADI 350 00 170 ADI 540 50 170 ADI 740 50
Number of inputs 1 x 16 2 x 16 2 x 8
Input voltage V 24 DC 120 AC 230 AC
Operating voltage V 24 DC 85…132 AC
(@ 47…63 Hz)
164…253 AC
(@ 47…63 Hz)
Internal current mA 250 (@ 24 Vdc) 125 (@ 120 Vac) 125 (@ 230 Vac)
Input voltage range V - 3…30 DC 0…132 AC 163…253 AC
ON voltage V+ 11…30 DC 74 AC minimum 164 AC minimum
OFF voltage V- 3…+ 5 DC 20 AC maximum 40 AC maximum
Input current ON mA 2.5 minimum 10.0 minimum
OFF mA 1.2 maximum 2.0 maximum
Input resistance k
W
4 9.5 @ 50 Hz
7.5 @ 60 Hz
9 @ 50 Hz
7.5 @ 60 Hz
Type of signal True High
Response time On-off maximum ms 3.3 35.0 @ 60 Hz 13.3 @ 60 Hz
Off-on maximum ms 2.2 10.0 @ 60 Hz 13.3 @ 60 Hz
Potential isolation Input to input None None
Group to group VNone 1780 AC
Field to communication interface V500 AC 1780 AC
Power dissipation W 3 typical,
5 maximum
5.5 typical,
8.5 maximum
Agency approvals UL, e, CSA, FM
Class I, Div. II
UL, e, CSA UL, e, CSA, FM
Class I, Div. II
UL, e, CSA
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
Specications
1
2
3
4
5
6
7
8
9
10
14
Modicon Momentum
automation platform
Discrete I/O bases
Specications for discrete output bases
Type of output base unit 170 ADO 340 00 170 ADO 350 00 170 ADO 830 30
Number of outputs 2 x 8 2 x 16 1 x 6
Type of output Solid state switch Relay form “C”
Output voltage V 24 DC 20…250 AC, 5…30 DC
Operating voltage V 24 DC 120…230 AC
Internal current mA 250 @ 24 Vdc 125 @ 120 Vac, 65 @ 230 Vac
Current Point maximum A0.5 0.5 5
Group A485
Module A8 16 21 @ 60 °C, 25 @ 30 °C
Min. output current mA 50
Leakage current mA < 1 @ 24 Vdc < 0.1 @ 120 Vac
Surge current A 5 for 1 ms 20 for 10 ms
On StateVoltage drop V < 0.5 DC @ 0.5 A < 0.2 @ 30 Vdc
Protection (short-circuits, overloads) Outputs electronically protected Via external 315 mA fast-blow fuse
Response time On-off maximum ms < 0.1 20 @ 60 Hz
Off-on maximum ms < 0.1 10 @ 60 Hz
Potential Isolation Output to output VNone 1780 AC for 1 minute
Output group to output group VNone 1780 AC for 1 minute
Field to communication interface V500 AC 1780 AC for 1 minute
Power dissipation W 3.5 typical
4.5 maximum
6.0 typical
7.5 maximum
2.5
Agency approvals UL, e, CSA,
FM Class I, Div. II
UL, e, CSA UL, e, CSA, FM Class I, Div. II
Type of output base unit 170 ADO 530 50 170 ADO 540 50 170 ADO 730 50 170 ADO 740 50
Number of outputs 2 x 4 2 x 8 2 x 4 2 x 8
Type of output Triac
Output voltage V 120 AC 230 AC
Operating voltage V 120 AC (300 for 10 s, 400 for 1 cycle) 230 AC (300 for 10 s, 400 for 1 cycle)
Internal current mA 125 65
Current Point maximum A2 0.5 2 0.5
Group A4
Module A8
Min. output current mA 5 30 5 30
Leakage current mA 1.9 @ 120 Vac 2.5 @ 230 Vac 2.4 @230 Vac
Surge current A Point: 15 (1 cycle), 10 (2 cycles), 5 (3 cycles)
On StateVoltage drop V < 1.5 AC @ 2 A < 1.5 AC @ 0.5 A < 1.5 AC @ 2 A < 1.5 AC @ 0.5 A
Protection (short-circuits, overloads) Via internal 5 A slow-blow fuse per group
Response time On-off maximum ms 1/2 x 1/f (= 0,5 of one line cycle)
Off-on maximum ms 1/2 x 1/f (= 0,5 of one line cycle)
Potential Isolation Output to output None
Output group to output group None
Field to communication interface V1780 AC
Power dissipation W 6.0 typical
7.5 maximum
Agency approvals UL, e, CSA, FM Class I, Div. II
Description:
page 12
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
Specications (continued)
1
2
3
4
5
6
7
8
9
10
15
Modicon Momentum
automation platform
Discrete I/O bases
Specications for discrete I/O bases
Type of base unit 170 ADM 350 10 170 ADM 350 11 170 ADM 350 15 170 ADM 390 10
Number of inputs 1 x 16 1 x 16
Number of outputs 2 x 8 1 x 8 and 1 x 4
Operating voltage Vdc 24
Internal current mA 250 @ 24 Vdc 180 @ 24 Vdc
Inputs Voltage Vdc 24
Type of signal True high True low True high
Voltage at 1 Vdc + 11…+ 30 - 3…+ 5 + 11…+ 30
Voltage at 0 Vdc - 3…+ 5 + 4…+ 30 - 3…+ 5
Input current mA 2.5 min. at state 1 (6 mA at c 24 V),1.2 max. at state 0
Input voltage range Vdc - 3…+ 30
Input resistance kW4
Response time Off to on ms 2.2 0.06 2.2 In, < 1 Out
On to off ms 3.3 0.08 3.3 In, < 1 Out
Fault sensing Broken wire
detection
Outputs Voltage Vdc 24, 30 max.
Type Solid state switch
Type of signal True high True low True high
Current capacity A0.5 per point
4 per group
8 per module
0.5 per point
4 per group 1
2 per group 2
6 per module
Leakage current mA < 1 @ 24 Vdc < 1 @ 24 Vdc
Peak current A5 for 1 ms
On state voltage drop Vdc < 0.5 @ 0.5 A
Detected error indication Output overload for at least one output to communication
adapter
Output overload for
at least one output
to communication
adapter
Response time Off to On ms < 0.1
On to Off ms < 0.1
Potential isolation Input to input None
Output to output group None
Input to output group None
Field to communication interface V500 AC
Power dissipation Typical W6.0 6.5
Maximum W8.0 10.0
Agency approvals UL, e, CSA UL, e, CSA, FM
Class I, Div. II
Description:
page 12
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
Specications (continued)
1
2
3
4
5
6
7
8
9
10
16
Modicon Momentum
automation platform
Discrete I/O bases
Specications for discrete I/O bases
Type of base unit 170 ADM 370 10 170 ADM 850 10
Number of points Inputs 4 x 4 1 x 16
Outputs 2 x 4 1 x 16
Operating voltage Vdc 24 12, 24, 48 (10…60)
Internal current mA 250 @ 24 Vdc (plus current for sensors) 500 @ 12 Vdc
250 @ 24 Vdc
125 @ 48 Vdc
Inputs Voltage Vdc 24 12, 24, 48
Type of signal True high
Voltage at 1 Vdc + 11…+ 30 > 7.5 @ 12 Vdc
> 11 @ 24 Vdc
> 30 @ 48 Vdc
Voltage at 0 Vdc - 3…+ 5 < 2.5 @ 12 Vdc
< 5 @ 24 Vdc
< 10 @ 48 Vdc
Input current mA 2.5 min. at state 1 (6 mA at c 24 V),
1.2 max. at state 0
2.3 @ 12 Vdc
2.7 @ 24 Vdc
2.9 @ 48 Vdc
Input voltage range Vdc - 3…+ 30 10…60 V
Input resistance kW4
Response time Off to On ms 2.2 In, < 1 Out 2.2 In, < 2.5 Out
On to Off ms 3.3 In, < 1 Out 3.3 In, < 2.5 Out
Fault sensing
Outputs Voltage Vdc 24, 30 max. 12, 24, 48, 60 max.
Type Solid state switch
Type of signal True high
Current capacity A2 per point
8 per group
16 per module
0.5 per point
8 per group @ 50 °C
7 per module @ 60 °C
Leakage current mA < 1 @ 24 Vdc < 1 @ 60 Vdc
Peak current A2.8 for 1 ms 5 for 1 ms
On state voltage drop Vdc < 1 @ 0.5 A
Detected error indication Output overload for at least one output or
short-circuit or overload on one of the 4
encoder supply groups, to communication
adapter
Output overload for at least one output to
communication adapter
Response time ms < 0.1 Off to On, < 0.1 On to Off
Potential isolation Input to input None
Output to output group None
Input to output group VNone 707 DC
Field to communication interface Vrms 500 AC 707 DC
Power dissipation Typical W6.5 6.0 + (0.144 x nb of input points)
+ (0.25 x nb of output points)
Maximum W10.0
Agency approvals UL, e, CSA UL, e, CSA, FM Class I, Div. II
Description:
page 12
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
Specications (continued)
1
2
3
4
5
6
7
8
9
10
17
Modicon Momentum
automation platform
Discrete I/O bases
Specications for discrete I/O bases
Type of base unit 170 ADM 390 30 /
170 ADM 390 31
170 ARM 370 30
Number of points
Inputs 1 x 10
Outputs 2 x 4
Operating voltage V 24 DC 120 AC (47...63 Hz)
Internal current mA 250 @ 24 Vdc 5 minimum load current
Inputs Voltage V24...230 AC
20...115 DC
Signal type True High
On voltage minimum Vdc + 11…+ 30
Off voltage maximum Vdc - 3...+ 5
Input current mA 2.5 minimum On, 1.2 maximum Off
Input voltage range Vdc - 3...+ 30
Input resistance kW4
Response time ms 2.2 Off to On, 3.3 On to Off
Outputs Voltage V24...230 AC, 20...115 DC /
24 Vdc (170 ADM 390 31 only)
Type Relay normally open
Current capacity 24 Vdc A> 0.005 (new contacts), ohmic load 2 A maximum, inductive load 1 A maximum
(LR y 40 ms)
Current capacity 115 Vdc AOhmic load 0.5 A maximum (switching current y 1.5 A), inductive load 0.15 A
maximum (LR y 40 ms)
Current capacity Vac A2 A maximum (switching current y 1.5 A)
cosj = 1 , 1 A maximum cosj = 0.5
2 A per point, 8 A per group, 16 A per
module
Leakage current mA < 1 @ 230 Vac
Detected error indication None
Response time ms 10 @ 60 Hz Off to On, 10 @ 60 Hz On to Off
Max. number of switching circuits > 30 x 106 (mechanical), > 1 x 105 (inductive load with external protection circuit)
Protection against short circuit
and overload
None Varistor in parallel with each contact
Potential isolation Input to Input None
Output group to output Group V rms None 1780 AC
Input to output group V rms None 1780 AC
Field to communication
interface V rms 500 AC
Fusing Internal None
External operating voltage 315 mA fast-blow 4 A fast-blow
External input voltage max. 4 A fast-blow None
External output voltage According to the supply of the connected
actuators not to exceed 8 A
slow-blow/group
None
Power dissipation Typical W5.5
Maximum W8.5
Agency approvals UL, e, CSA UL, e, CSA, FM Class I, Div. II
Description:
page 12
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
Specications (continued)
1
2
3
4
5
6
7
8
9
10
18
Modicon Momentum
automation platform
Discrete I/O bases
Specications for discrete I/O bases
Type of base unit 170 ADM 690 51
Number of points Inputs 1 x 10
Outputs 1 x 8
Operating voltage Vac 120 (47...63 Hz)
Internal current mA 160 (@ 120 Vac)
Inputs Voltage Vac 120
Signal type True high
On voltage minimum Vac 74
Off voltage maximum Vac 20
Input current mA 6.0 minimum at state 1, 2.6 maximum at state 0
Input voltage range Vac 74...132
Input resistance kW4
Response time ms Maximum 1/2 x 1/f Off to On, maximum 1/2 x 1/f On to Off
Outputs Voltage Vac 120…132 (@ 47…63 Hz)
Type Triac
Current capacity 0.5 A per point maximum, 30 mA per point minimum, 2 A per group, 4 A per module
Leakage current mA < 1.3 (@ 120 Vac)
Signal type True High
On state voltage drop Vac < 1.5 (@ 0.5 A)
Detected error indication None
Response time ms 1/2 x 1/f maximum from state 0 to state 1, 1/2 x 1/f maximum from state 1 to state 0
Maximum switching cycles 3000/hr for 0.5 A inductive load
Potential Isolation Input to input None
Output group to output group None
Input to output group None
Field to communication interface Vrms 1780 AC
Power dissipation Typical W6
Maximum W8
Protection Internal fuses A2 x 2.5 slow-blow fuses
Agency approvals UL, e, CSA
Description:
page 12
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams:
pages 20 to 25
Specications (continued)
1
2
3
4
5
6
7
8
9
10
19
Modicon Momentum
automation platform
Discrete I/O bases
Discrete input bases
Type of current Modularity
(no. of points)
Conformity
EC 1131-2
Reference
Weight
kg
DC 24 V 16 (1 x 16) Type 1 170 ADI 340 00 0.190
32 (2 x 16) Type 1 170 ADI 350 00 0.200
AC 120 V 16 (2 x 8) Type 2 170 ADI 540 50 0.284
230 V 16 (2 x 8) Type 2 170 ADI 740 50 0.284
Discrete output bases
Type of current Output voltage Modularity
(no. of points)
Current per
output
Reference
Weight
kg
DC solid state
protected
24 V 16 (2 x 8) 0.5 A 170 ADO 340 00 0.210
32 (2 x 16) 0.5 A 170 ADO 350 00 0.210
DC/AC relay form “C” 5…24 Vdc
24…230 Vac
6 isolated 5 A 170 ADO 830 30 0.260
AC triac
protected,
1 fuse per group
120 V 8 (2 x 4) 2 A 170 ADO 530 50 0.320
16 (2 x 8) 0.5 A 170 ADO 540 50 0.284
230 V 8 (2 x 4) 2 A 170 ADO 730 50 0.320
16 (2 x 8) 0.5 A 170 ADO 740 50 0.284
Discrete I/O bases
Type of output current Input
voltage
Output
voltage
Modularity Reference
Weight
kg
Input Outputs, current
DC solid state 24 Vdc
Type 1+
24 Vdc
protected
16 I (1 x 16) 16 O (2 x 8) 0.5 A 170 ADM 350 10 0.200
16 I, fast (1 x 16) 16 O (2 x 8) 0.5 A 170 ADM 350 11 0.200
16 I (1 x 16) 16 O (2 x 8) 0.5 A 170 ADM 350 15 0.200
16 I, wiring
check (1 x 16)
12 O (1 x 8 and 1 x
4) 0.5 A
170 ADM 390 10 0.260
16 I (4 x 4) 8 O (2 x 4) 2 A 170 ADM 370 10 0.220
DC relay 12…60 Vdc 12…60 Vdc 16 I (1 x 16) 16 O (1 x 16) 0.5 A 170 ADM 850 10
AC or DC relay 24 Vdc
Type 1+
24/230 Vac
20/115 Vdc
10 I (1 x 10) 8 O (2 x 4) 2 A 170 ADM 390 30 (1) 0.260
170 ARM 390 31 (2) 0.260
170 ARM 370 30 (3) 0.260
AC triac 100…120
Vac
Type 2
120 Vac 10 I (1 x 10) 8 O (1 x 8) 0.5 A
protected by 1 fuse
170 ADM 690 51 0.220
Accessories
Description Composition Type of connection Reference
Weight
kg
Terminal blocks for I/O
base connection
Set of 3 connectors
1 row Screw 170 XTS 001 00
Spring 170 XTS 002 00
Bus Bar 3 rows Screw 170 XTS 004 01
Spring 170 XTS 003 01
2 rows Screw 170 XTS 005 01
Spring 170 XTS 008 01
1 row Screw 170 XTS 006 01
Spring 170 XTS 007 01
Cable grounding rail Used to connect
the cable shielding
CER 001
High vibration
environment clips
Kit containing 5 sets of clips 170 XTS 120 00
Dummy base unit Used to prewire the I/O base units
Requires screw or spring connection terminals
170 BDM 090 00
Discrete input simulator 16 channels, 24 Vdc 170 BSM 016 00
Replacement parts
Description Use Reference Weight
kg
Sheets of labels 10 front labels for Modicon Momentum modules 170 XTS 100 00
Cable coding
part kit
For screw or spring connection terminals 170 XCP 200 00
(1) Operating voltage 24 Vdc.
(2) Output voltage 24 Vdc.
(3) Operating voltage 120 Vac.
170 ADO pp0 p0
170 XTS 002 00
170 XTS 004 01
170 XTS 008 01
170 XTS 006 01
CER 001
170 BSM 016 00
References
Description:
page 12
Specications:
pages 13 to 18
Wiring diagrams:
pages 20 to 25
1
2
3
4
5
6
7
8
9
10
20
Modicon Momentum
automation platform
Discrete I/O bases
Dimensions, mounting
170 ADp, rail or panel mounting
(1) 2 holes for M4 screws, for panel mounting (1) Equipment or enclosure
Wiring diagrams for discrete input bases
170 ADI 340 00 170 ADI 350 00
Example of external wiring of 2, 3 and 4-wire sensors Example of external wiring of 2 and 3-wire sensors
Group of channels Group of channels
Internal wiring Internal wiring
170 ADI 540 50 170 ADI 740 50
Example of external wiring of 2 and 3-wire sensors Example of external wiring of 2 and 3-wire sensors
Group of channels Group of channels
Internal wiring Internal wiring
(1)
107
125
93
141,5
47,5
62
125 60
(1)
IN +-PE
2L1
2N
1L1
1N
1
2
3
123456 78910111213141516NL1
120 V 120 V
4-wire sensor
2-wire sensor
Return Return
200 mA
slow-blow
fuse
2-wire sensor
IN +- PE
2L1
2N
1L1
1N
1
2
3
1234 5678910 11 12 13 14 15 16 NL1
230 V 230 V
Return
Return
200 mA
slow-
blow
fuse
4-wire sensor
2-wire sensor 2-wire sensor
Description:
page 12
Specications:
pages 13 to 18
Dimensions,
mounting,
wiring diagrams
IN +– IN +–
2L+1L+
M–M–1L+
1
2
3
12345678910 11 12 13 14 15 16 M– L+
2L+2L+
M–M–
M–M–
24 V
24 V
4 A max.
fast-blow
fuse
Return
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
3-wire sensor 3-wire sensor
2-wire sensor
Option
IN +–
IN +–PE
1L+
M–
1
2
3
12345678910 11 12 13 14 15 16 M– L+
PE
24 V
Return
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
2-wire sensor
3-wire sensor
4-wire sensor
Option
1
2
3
4
5
6
7
8
9
10
21
Modicon Momentum
automation platform
Discrete I/O bases
Wiring diagrams for discrete output bases
170 ADO 340 00 170 ADO 350 00
Example of external wiring of 2 and 3-wire actuators Example of external wiring of 2 and 3-wire actuators
Group of channels Group of channels
Internal wiring Internal wiring
170 ADO 830 30
Example of external wiring
Group of channels
Internal wiring
+
PE
Out
PE
L+
1
2
3
123456789101112131415161L+ 2L+
M–
24 V
24 V
Return
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
315 mA
fast-blow
fuse
Option
2-wire actuator
3-wire actuator
+
Out–PE
Out–PE
2L+1L+
M–M–
1
2
3
12345678910 11 12 13 14 15 16M– L+
M–
PE
PE
PE
24 V
24 V
12345678910 11 12 13 14 15 16
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
Return
Option
3-wire actuator 3-wire actuator
2-wire actuator
1
2
3
12345678910 11 12 13 14 15 16M– L+
PE
12345678910 11 12 13 14 15 16
L
N
17 18
12345678910 11 12 13 14 15 16 17 18
01 02 03 04 05 06
01 02 03 04 05 06
Option
NO
NF
Output 1 Output 4 Output 6
Fast-blow
fuse
315 mA
120/230 VCA
Description:
page 12
Specications:
pages 13 to 18
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams (continued)
1
2
3
4
5
6
7
8
9
10
22
Modicon Momentum
automation platform
Discrete I/O bases
Wiring diagrams for discrete output bases
170 ADO 530 50/ADO 540 50 170 ADO 730 50/ADO 740 50
Example of external wiring of 2 and 3-wire actuator Example of external wiring of 2 and 3-wire actuators
Group of channels Group of channels
Internal wiring Internal wiring
Out-PE
L1N
1
2
3
PE
12345678910 11 12 13 14 15 16 1N 1L1
LN
120 V
120 V
Fuse 2 (5 A slow-blow)Fuse 1(5 A slow-blow) Return
Return
2-wire actuator
3-wire actuator
Option
200 mA
fast-blow
fuse
10 A
fast-blo
w fuse
LN
Out-PE
L1N
1
2
3
PE
123456789101112131415161N1L1
230 V
230 V
Fuse 1(5 A slow-blow) Fuse 2 (5 A slow-blow)
Return
Return
Option
10 A
fast-blow
fuse
200 mA
fast-blow
fuse
2-wire actuator
3-wire actuator
Description:
page 12
Specications:
pages 13 to 18
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams (continued)
1
2
3
4
5
6
7
8
9
10
23
Modicon Momentum
automation platform
Discrete I/O bases
Wiring diagrams for discrete I/O bases
170 ADM 350 10/ADM 350 11/ADM 350 15
Example of external wiring of a 2-wire sensor/actuator Example of external wiring of a 3-wire actuator with wiring check
Group of channels Group of channels
Internal wiring Internal wiring
Example of external wiring of a 4-wire sensor activated by an output Example of external wiring of a 4-wire sensor/2-wire actuator
Group of channels Group of channels
Internal wiring Internal wiring
3L+
12345678
12345678
91012131516M–L+
1411
91012131516
1411
I6 O6
M–M–
1
2
3
1L12L+
24 V
24 V
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
Return
Option
2-wire sensor
2-wire actuator
PE
12345678910 12 13 15 16 M– L+
1411
OutPE
M–M
1
2
3
1L12L+
24 V
24 V
12345678910 12 13 15 16
1411
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
Return
3-wire actuator
Option
PE
12345678910 12 13 15 16M– L+
1411
IN +–PE
M–M–
1
2
3
1L12L+
24 V
24 V
12345678910 12 13 15 16
1411
2-wire sensor
4-wire sensor
Option
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
Return
12345678910 12 13 15 16 M– L+
1411
3L+
M–
PE
IN +–PE
M–M–
1
2
3
1L12L+
24 V
24 V
12345678910 12 13 15 16
1411
Return
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
4-wire sensor
2-wire actuator
Option
Option
Wiring diagrams (continued)
Description:
page 12
Specications:
pages 13 to 18
References:
page 19
Dimensions, mounting:
page 20
1
2
3
4
5
6
7
8
9
10
24
Modicon Momentum
automation platform
Discrete I/O bases
Wiring diagrams for discrete I/O bases
170 ADM 390 10 170 ADM 370 10
Example of external wiring of 2-wire sensor/actuator Example of external wiring of 2 and 4-wire sensors/2-wire actuator
Group of channels Group of channels
Internal wiring Internal wiring
170 ADM 370 10 (continued)
Example of external wiring of 3-wire actuator with wiring check Special external wiring, the output activates the sensor
Group of channels Group of channels
Internal wiring Internal wiring
12345678910 12 13 15 16 M–L+
1411
M–
PE
IN +–PE
+
2M1M
1
2
3
1L+2L+
L+
L+L+L+
24 V
24 V
12345678910 12 13 15 16
1411
4-wire sensor 2-wire actuator 2-wire sensor
8 A max.
slow-blow
fuse
8 A max.
slow-blow
fuse
4 A max.
fast-blow
fuse
Option
Return
12345678910 12 13 15 16 M– L+
1411
M
PE
OutPE
2M1M
1
2
3
1L+2L+
L+
L+L+L+
24 V
24 V
12345678910 12 13 15 16
1411
Option
Return
8 A max.
slow-blow
fuse
8 A max.
slow-blow
fuse
4 A max.
fast-blow
fuse
3-wire actuator
12345678910 12 13 15 16 M–L+
1411
M
PE
IN +–PE
2M1M
1
2
3
1L+2L+
L+
L+L+L+
24 V
24 V
12345678910 12 13 15 16
1411
Option
4-wire sensor
Return
8 A max.
slow-blow
fuse
8 A max.
slow-blow
fuse
4 A max.
fast-blow
fuse
Description:
page 12
Specications:
pages 13 to 18
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams (continued)
3L+
12345678910 12 13 15 16 M– L+
1411
I6
O6
M–M–
1
2
3
9121L+ 2L+18
56 k
56 k
24 V
24 V
2-wire actuator
(connected directly
to sensor)
Option
Return
200 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
4 A max.
fast-blow
fuse
1
2
3
4
5
6
7
8
9
10
25
Modicon Momentum
automation platform
Discrete I/O bases
Wiring diagrams for discrete I/O bases
170 ADM 850 10 170 ADM 390 30 / 170 ADM 390 31
Example of external wiring of:
v 4-wire sensor
v 2-wire actuator
v 3-wire actuator with wiring check
v 2-wire sensor actived by output
Example of external wiring of 3 or 4 sensor/3-wire/actuator
Group of channels Group of channels
Internal wiring Internal wiring
(1) Fast-blow fuse: c 12 V: 630 mA, c 24 V: 315 mA, c 48 V: 200 mA.
(2) Fast-blow fuse.
(1) For 4-wire sensor
(2) For 3-wire actuator
170 ARM 370 30 170 ADM 690 51
Example of external wiring of 4-wire sensor/3-wire actuator Example of external wiring of 4-wire sensor/2 and 3-wire actuators
Group of channels Group of channels
Internal wiring Internal wiring
+
1M-1L+
16 2M-2L+
1
2
3
12345678910 11 12 13 14 15 16 M-L+
12345678910 11 12 13 14 15 16
In –PE
+
P
4M
In PE
10M
P
(1)
(2)
(2)
(2)
4
5
6
10…60 V
10…60 V
I1 I10 I14
O4 O10 O14
Return
2-wire
actuator 3-wire
actuator
315 mA
max. 4 A
max. 10 A
4-wire
sensor
Sensor
actived by
output
PE
123456789101L+ M– M– 1L +M–L+
IN L-PE
2N1N
1
2
3
1L +9 10 161L +2L1
1N
M– 2N
L-PE
24 V
L
N
(2)(1)
Option
3-wire sensor 2-wire actuator
Return
315 mA
fast-blow
fuse
4 A max.
fast-blow
fuse
8 A max.
slow-blow
fuse
8 A max.
slow-blow
fuse
PEPEPE
16



N

1L
IN PE

2N1N
1
2
3
4







L+
+
12




1L +2L1
1N
M
IN PE
8 A max.
slow-blow
fuse
4 A max.
fast-blow
fuse
a 120 V
N
4-wire sensor 3-wire actuator
Return
2L1
2N
PE
1L11N1N
2
3
4
5
6
1234 56 78910NCN2N L1
81N 1N1N
LN
1
INLNPE OutNPE
2-wire
sensor
4-wire sensor
2-wire actuator
Fuse 1
(2,5 A slow-blow)
Fuse 2
(2,5 A slow-blow) Return
Return
Return
a 115 V
a 20…132 V
a 115 V
315 mA
fast-blow
fuse
8 A max.
slow-blow
fuse
4 A max.
fast-blow
fuse
3-wire actuator
Description:
page 12
Specications:
pages 13 to 18
References:
page 19
Dimensions, mounting:
page 20
Wiring diagrams (continued)
1
2
3
4
5
6
7
8
9
10
26
Modicon Momentum
automation platform
Analog I/O bases
Applications
24 Vdc analog input bases
Operating voltage 24 Vdc
Measurement range Inputs
± 5 V, ± 10 V, ± 20 mA
1-5 V, 4-20 mA
Inputs
± 5 V, ± 10 V, 4-20 mA
Inputs
± 25 mV, ± 100 mV,
Temperature probe
Pt 100, Pt 1000, Ni 100,
Ni 1000
Thermocouple
B, E, J, K, N, R, S, T
Modularity Input channels 8 differential inputs 16 single-ended inputs 4 differential inputs
Output channels
Discrete I/O
–––
Resolution
14 bits + sign bipolar
15 bits unipolar
12 bits + sign 15 bits + sign
Update time
1.33 + 1.33 x no. of declared
channels (ms)
1 + 1.5 x no. of declared
channels (ms
500 ms
Potential isolation Between channels 200 Vdc, 1 min None 400 Vdc
Base and ground 500 Vdc, 1 min 500 Vdc, 1 min 500 Vdc, 1 min
Channels and ground 500 Vac, 1 min 1780 Vac, 1 min 500 Vac
Protection Polarity inversion
Number in words In 8 words in 16 words in 4 words in
Out 2 words out 4 words out 4 words out
Fail states
Type of communicating module 170 AAI 030 00 170 AAI 140 00 170 AAI 520 40
Pages 34
24 Vdc analog output bases
24 Vdc mixed I/O bases (analog/discrete)
24 Vdc 12 Vdc 24 Vdc
Outputs
± 10 V, 0-20 mA
Outputs
± 10 V, 4-20 mA
Inputs
± 5 V, ± 10 V, ± 20 mA
1-5 V, 4-20 mA
Outputs
± 10 V, 0-20 mA
Inputs
0…10 V
Outputs
0…10 V
Inputs
- 10…+ 10 V
Outputs
- 10…+ 10 V
4 differential inputs 6 inputs with common point
4 outputs 2 outputs 4 outputs with common point
4 inputs 24 Vdc
2 outputs 24 Vdc/0.5 A
4 inputs 12 Vdc
2 outputs 12 Vdc/1 A
8 inputs 24 Vdc
8 outputs 24 Vdc/0.25 A
12 bits + sign Inputs: 12…14 bits
(dep. on range)
Outputs: 12 bits
Inputs: 14 bits
Outputs: 14 bits
2 ms Inputs: 10 ms
Outputs: 1 ms
Inputs: 0.75 ms (for 6 inputs)
Outputs: 1.2 ms (for 4 inputs)
None None
500 Vdc, 1 min 500 Vac, 1 min
500 Vac, 1 min 500 Vac, 1 min
Polarity inversion Short-circuits and overloads (for discrete outputs)
5 words in 5 words in 12 words in
5 words out 5 words out 5 words out 12 words out
Hold, reset to zero, reset to full scale Hold or reset to zero
170 AAO 120 00 170 AAO 921 00 170 AMM 090 00 170 AMM 090 01 170 ANR 120 90 170 ANR 120 91
34
Selection guide
1
2
3
4
5
6
7
8
9
10
27
24 Vdc analog output bases
24 Vdc mixed I/O bases (analog/discrete)
24 Vdc 12 Vdc 24 Vdc
Outputs
± 10 V, 0-20 mA
Outputs
± 10 V, 4-20 mA
Inputs
± 5 V, ± 10 V, ± 20 mA
1-5 V, 4-20 mA
Outputs
± 10 V, 0-20 mA
Inputs
0…10 V
Outputs
0…10 V
Inputs
- 10…+ 10 V
Outputs
- 10…+ 10 V
4 differential inputs 6 inputs with common point
4 outputs 2 outputs 4 outputs with common point
4 inputs 24 Vdc
2 outputs 24 Vdc/0.5 A
4 inputs 12 Vdc
2 outputs 12 Vdc/1 A
8 inputs 24 Vdc
8 outputs 24 Vdc/0.25 A
12 bits + sign Inputs: 12…14 bits
(dep. on range)
Outputs: 12 bits
Inputs: 14 bits
Outputs: 14 bits
2 ms Inputs: 10 ms
Outputs: 1 ms
Inputs: 0.75 ms (for 6 inputs)
Outputs: 1.2 ms (for 4 inputs)
None None
500 Vdc, 1 min 500 Vac, 1 min
500 Vac, 1 min 500 Vac, 1 min
Polarity inversion Short-circuits and overloads (for discrete outputs)
5 words in 5 words in 12 words in
5 words out 5 words out 5 words out 12 words out
Hold, reset to zero, reset to full scale Hold or reset to zero
170 AAO 120 00 170 AAO 921 00 170 AMM 090 00 170 AMM 090 01 170 ANR 120 90 170 ANR 120 91
34
1
2
3
4
5
6
7
8
9
10
28
Modicon Momentum
automation platform
Analog I/O bases
Introduction
Modicon Momentum analog input bases enable acquisition of various analog
values encountered in industrial applications, including:
b Standard high level (
±
5 V,
±
10 V, 1-5 V, 4-20 mA,
±
20 mA)
b Low level (
±
25 mV,
±
100 mV)
b Thermocouples (B, E, J, ...)
b Temperature probes (Ni ..., Pt ...)
Analog output bases are used to control analog eld devices such as: speed drives
and proportional control valves. The current or the voltage is proportional to the
digital value dened by the user program. The outputs can be congured so that
when the program stops, the outputs either reset to zero or hold the last value
received. This feature is useful during debugging because, if the outputs are set to
“Hold”, the operation of the analog eld devices is not disturbed every time the
program stops.
Designed to cover a wide range of applications, Modicon Momentum I/O bases offer
the following functions in addition to A/D or D/A conversion:
b Choice of input/output ranges (voltage, current, thermocouple,
temperature probes)
b Selection of number of channels used
b Cold junction compensation for thermocouple modules
b
Broken wire detection (170 AAI 030 00, 170 AAI 140 00 and 170 AAI 520 40 models)
Description
170 App analog I/O base units feature the following on the front panel:
1 Internal interface connector for the communication module or processor module
2 Locking and ground contact for the communication module or processor module
3 LED status indicators (the number of indicators will depend on the number
of channels)
4 Two connectors for the removable terminal blocks
5 Grounding screw
6 Slot for the power strip
7 Two screw holes for panel mounting
8 Protective cover
Connectors to be ordered separately:
b removable screw or spring terminal blocks 170 XTS 00p 00
b 1 to 3-row screw or spring bus bar 170 XTS 00p 01
1
6
2
3
8
7
4
5
4
7
Introduction,
description
1
2
3
4
5
6
7
8
9
10
29
Modicon Momentum
automation platform
Analog I/O bases
Specications for analog input bases
Type of base units 170 AAI 030 00
Number of inputs 1 x 8 differential imputs
LEDs Ready (green)
Format of data Full 16 bits signed (2’s complement)
Protection Base and actuators Polarity inversion
Ranges ± 10 Vdc ± 5 Vdc 4…20 mA ± 20 mA 1…5 Vdc
Input impedance kW> .1000 > .1000 250 250 > .1000
Maximum variation at 25 °C %0.27 0.21 0.27 0.32 0.13
Maximum variation at 60 °C %0.32 0.26 0.38 0.41 0.19
Resolution 14 bits + sign bipolar
15 bits unipolar
Conversion times ms 12 ms max. for 8 input channels
(1.33 ms per input channel + 1.33 ms)
Error indication None
Isolation Channel to channel Vdc ± 200 for 1 minute
Field to ground Vdc 500 for 1 minute
Communication adapter to
ground
Vac 500 for 1 minute
Common mode rejection Channel to ground 250 Vac @ 47…63 Hz or 100 Vdc
Crosstalk between channels dB u 80
External power requirement Nominal Vdc 24
Limit values Vdc 20.4 to 28.8
Current mA < 382 @ 24 Vdc
EMC for industrial
environment
Immunity IEC 1131 surge on auxiliary power supply 2 kV
Emissions EN 50081-2
Approvals UL, CSA, e
References :
pages 34 and 35
Dimensions :
page 35
Wiring diagrams :
pages 36 and 37
Specications
1
2
3
4
5
6
7
8
9
10
30
Modicon Momentum
automation platform
Analog I/O bases
Specications for analog input bases
Type of base units 170 AAI 140 00 170 AAI 520 40
Number of inputs 1 x 16 single-ended input 1 x 4 differential inputs
Format of data Full 16 bits signed (2’s complement)
Protection Base and actuators Polarity inversion
Error indication None
Ranges ± 10 V ± 5 V 4…20 mA ± 25 mV ± 100 mV
Input impedance kW> 2200 > 2200 < 0.250 > 10000 > 10000
Maximum variation at 25 °C 0.15 % FS 0.15 % FS 0.25 % FS ± 21 µV ± 27 µV
Maximum variation at 60 °C 0.25 % FS 0.25 % FS 0.45 % FS ± 46 µV ± 94 µV
Temperature drift (60 °C) 30 PE / °C 30 PE / °C 60 PE / °C
PE (Full scale) 10 V 5 V 16 mA
Resolution 12 bits + sign 12 bits + sign 12 bits 15 bits + sign
Filtering Low pass with cut-off frequency 10 kHz
Current source Pt100 mA 0.125
Ni100 mA 0.125
Pt1000 mA 0.125
Ni1000 mA 0.125
Update time ms 1 + 1.5 x n
n = number of declared channels
500
Error indication None
Potential isolation Channel to channel Vdc None 400
Base power supply and ground Vdc 500 for 1 minute 500 for 1 minute
Channels to ground Vac 1780 for 1 minute 500 for 1 minute
Base power V± 30 (voltage or current output) ± 30 (voltage or current output)
Common mode
Channel to ground
V ± 100 DC, 250 AC
Common mode
Voltage between channels
V 200 DC, 115 AC single phase or 3-phase
or 250 AC single phase
Common mode rejection Channel to ground 250 Vac at 47…63 Hz or 100 Vdc 135 dB DC, 145 dB AC 50 Hz, 155 dB AC
60 Hz
Between channels 120 dB DC, 130 dB AC 50 Hz, 140 dB AC
60 Hz
Serial mode rejection 35 dB AC 50 Hz, 45 dB AC 60 Hz
Input protection Polarity inversion
Operating voltage Vdc 24
Internal current mA 305 @ 24 Vdc
Power dissipation Typical W4.95 3.5
Maximum W5.55 5.5
Fusing Internal 2 A slow-blow 2 A slow-blow
External 500 mA fast-blow 500 mA fast-blow
Agency approvals UL, e, CSA, FM Class I, Div. II
References :
pages 34 and 35
Dimensions :
page 35
Wiring diagrams :
pages 36 and 37
Specications (continued)
1
2
3
4
5
6
7
8
9
10
31
Modicon Momentum
automation platform
Analog I/O bases
Specications for analog output bases
Type of base units 170 AAO 120 00 170 AAO 921 00
Number of outputs 1 x 4
Format of data Full 16 bits signed (2’s complement)
Protection Base and actuators Polarity inversion
Ranges ± 10 V 0…20 mA ± 10 V 4…20 mA
Load impedance kW1 minimum 0.6 maximum 1 minimum 0.6 maximum
Capacitive load µF < 1
Maximum variation at 25 °C %0.2 PE 0.3 PE 0.2 PE 0.4 PE
Maximum variation at 60 °C %0.25 PE 0.4 PE 0.25 PE 0.5 PE
Temperature drift (60 °C) 10 PE / °C 30 PE / °C 10 PE / °C 30 PE / °C
Resolution 12 bits + sign
Update time ms < 2
Full scale 10 V in the range of ± 10V
2 mA in the range of 0…20 mA
Fail State Hold, reset to zero, reset to full scale
Potential isolation Channel to channel None
Base power supply and ground Vdc 500 for 1 minute
Channels to ground Vac 500 for 1 minute
Outprotections Short-circuits in the voltage circuits, open in current polarity inversion
Base power V± 30 (voltage or current output)
Common mode rejection Vac 250 @ 47…63 Hz or 250 DC channel to ground
Operating voltage Vdc 24
Internal current Base mA 530 @ 24 Vdc
Actuators mA 150 @ 24 Vdc
Power dissipation Typical W5.6
Maximum W8.5
Internal fusing A 2, slow-blow
Agency approvals UL, e, CSA
References :
pages 34 and 35
Dimensions :
page 35
Wiring diagrams :
pages 36 and 37
Specications (continued)
1
2
3
4
5
6
7
8
9
10
32
Modicon Momentum
automation platform
Analog I/O bases
Specications for discrete and analog I/O bases
Type of base unit 170 AMM 090 00 170 AMM 090 01
Number of inputs and outputs 1 x 4 differential inputs
1 x 4 discrete inputs
1 x 2 analog outputs
1 x 2 discrete outputs
Operating voltage Vdc 24 12
Internal current mA 200 typical (at 24 Vdc), 350 maximum
(at 24 Vdc)
700 maximum (at 12 Vdc)
Differential inputs for
170 AMM 090 00/090 01
Conversion time 10 ms for all channels
Conversion tolerance ± 10 V ± 5 V 1…5 V ± 20 mA 4…20 mA
25 °C %0.08 0.16 0.16 0.16 0.16
60 °C %0.15 0.3 0.3 0.3 0.3
Resolution 14 bits 13 bits 12 bits 13 bits 12 bits
Conversion consistency %± 0.02 ± 0.04 ± 0.04 ± 0.04 ± 0.04
Common mode voltage Input voltage starting at Ag ± 11 V
Common mode suppression dB > 54 80
Overvoltage
Voltage ranges
V± 30 solid state if voltage is 24 V
± 50 dynamic max. 100 ms
± 30 solid state if voltage is 12 V
± 50 dynamic max. 100 ms
Overvoltage current ranges mA > 48
Input resistance W1 M 250
Fail state Hold or reset to zero
Discrete inputs Voltage Vdc 24 typical, 30 maximum 12 typical
Signal Type True high
On Voltage Vdc + 11…+ 30 + 7.5…+ 15
Off Voltage Vdc - 3…+ 5 - 1.5…+ 2.5
Input current mA 2.5 minimum at state 1 (6 mA at operating voltage), 1.2 maximum at state 0
Input resistance kW4 2.1
Response time ms 2.2 from 0 to state 1
3.3 from 1 to state 0
Analog outputs Resolution 12 bits for single-phase measuring range 0…20 mA, 12 bits for 2-phase measuring
range ± 10 V
Conversion time ms 1 for all channels
Conversion
maximum
variation
25 °C max. ± 0.35 % of upper measuring range value
60 °C max. ± 0.70 % of upper measuring range value
Output load u 3 kW for voltage output, y 600 W for current output
Discrete outputs Voltage Vdc 24 typical, 30 maximum
Type Semiconductor
Signal Type True high
Current capacity 1 per channel, 2 per group, 2 per module
Leakage current mA < 1 @ 24 Vdc < 1 @ 12 Vdc
On State Voltage drop Vdc < 0.5 @ 1 A < 0.5 @ 0.5 A
Response time Off to On ms < 0.1
On to Off ms < 0.1
Output protection The outputs are protected against overload and short-circuit-circuiting
Output indicator 1 red LED per “On” output in the event of an overload or short-circuit-circuiting
Error message Message “I/O error” on bus adapter if module is defective
Max. Switching cycles 1000/hr (inductive load 1 A), 100/s (resistive load 1 A), 8/s (lament load 2.4 W)
Potential isolation Discrete input and output None
Analog input to output None
Analog input and output and to
operating voltage
Vac 500 for 1 minute
Operating voltage and inputs
and outputs from ground
Vac 500 for 1 minute
Power dissipation Typical W4.0
Maximum W6.0
Agency approvals UL, e, CSA, FM Class I, Div. II UL, e, CSA
References :
pages 34 and 35
Dimensions :
page 35
Wiring diagrams :
pages 36 and 37
Specications (continued)
1
2
3
4
5
6
7
8
9
10
33
Modicon Momentum
automation platform
Analog I/O bases
Specications for discrete and analog I/O bases
Type of base unit 170 ANR 120 90 170 ANR 120 91
Number of inputs and outputs 1 x 6 analog inputs
2 x 4 discrete inputs
1 x 4 analog outputs
1 x 8 discrete outputs
Operating voltage Vdc 24, range 19.2...30
Internal current mA 400 @ 24 Vdc
Analog inputs Resolution 14 bit
Input range Vdc 0...10 - 10...+ 10
Input type Single-ended
Conversion time 0.75 ms maximum for 6 input channels
Conversion tolerance 0.2 % @ 25 °C for 0 - 10 Vdc inputs
Max input signal Vdc 15 for voltage input
Max temperature drift Vdc 10 inputs
Input resistance MW>1 for voltage inputs
Discrete inputs Voltage Vdc 24
Conguration 2 groups of 4 inputs
Signal Type True high
Minimum on voltage Vdc > 11
Maximum off voltage Vdc < 5
Input current Minimum On mA 6
Maximum Off mA 2
Input voltage
Range Vdc + 3...+ 32
Surge Vdc 45 peak for 10 ms
Response time Off to On ms 1.2,
On to Off ms 1.2
Analog outputs Resolution 14 bit
Output range Vdc 0...10 - 10...+ 10
Conversion time ms 1.20 for four channels
Conversion tolerance max. + 0.4 % of upper measuring range value @ 25 °C
Output load > 2 kW minimum @ 0...10 Vdc
Fail state Hold or reset to zero
Discrete outputs Voltage Vdc 10-30 operating, 50 for 1 ms maximum
Type Solid State Switch
Signal type True high
Current capacity A0.25 per point, 2 per group, 2 per module
Leakage current mA 0.4 @ 30 Vdc
Surge current A2.5 for 1 ms
On state voltage drop Vdc < 0.4 @ 0.25 A current
Response time Off to On ms 1.2
On to Off ms 1.05
Output protection The Outputs are protected against overload and short-circuiting
Output indicator 1 LED per point
Potential isolation Discrete input to output None
Analog input to output None
Analog input and output to
operating voltage
Vac 500 for 1 minute.
Operating voltage and
inputs
and outputs from ground
Vac 500 for 1 minute
Power dissipation Typical W4.0
Maximum W6.0
Agency approvals UL, e, CSA
References :
pages 34 and 35
Dimensions :
page 35
Wiring diagrams :
pages 36 and 37
Specications (continued)
1
2
3
4
5
6
7
8
9
10
34
Modicon Momentum
automation platform
Analog I/O bases
Analog input bases
Type of inputs Number of
channels
Ranges Reference
Weight
kg
12 bits + sign 16 single-ended ± 5 V, ± 10 V, 4-20 mA 170 AAI 140 00 0.215
15 bits + sign 4, differential Pt 100, Pt 1000, NI 100
thermocouples B, E, J, K,
N, R, S, T
170 AAI 520 40 0.215
8, differential ± 5 V, ± 10 V, 1-5V
± 20 mA, 4-20 mA
170 AAI 030 00 0.215
Analog output bases
Type of outputs Number of
channels
Ranges Reference
Weight
kg
12 bits + sign 4 ± 10 V, 0-20 mA 170 AAO 120 00 0.215
± 10 V, 4-20 mA
170 AAO 921 00 0.215
Discrete and analog I/O bases
Type Ranges Reference
Weight
kg
Inputs Outputs Inputs Outputs
4 differential analog
13 bits + sign
2 analogs
12 bits
± 5 V, ± 10 V
1-5 V
± 20 mA
4-20 mA
0-20 mA
± 10 V
170 AMM 090 00 0.240
4 discretes 2 discretes
0.5 A
24 Vdc 24 Vdc
4 differential analog
13 bits + sign
2 analogs
12 bits
± 5 V, ± 10 V
1-5 V
± 20 mA
4-20 mA
0-20 mA
± 10 V
170 AMM 090 01 0.240
4 discretes 2 discretes
0.5 A
12 Vdc 12 Vdc
6 analog
14 bits
4 analogs
14 bits
0-10 V 0-10 V 170 ANR 120 90 0.240
2 x 4 discretes 1 x 8 discretes
0.25 A
24 Vdc 24 Vdc
6 analog
14 bits
4 analogs
14 bits
± 10 V ± 10 V 170 ANR 120 91 0.240
2 x 4 discretes 1 x 8 discretes
0.25 A
24 Vdc 24 Vdc
170 AAI pp0 p0
170 AAO p2p 00
170 AAM 090 00
Specications :
pages 29 to 33
Dimensions :
page 35
Wiring diagrams :
pages 36 and 37
References
1
2
3
4
5
6
7
8
9
10
35
Modicon Momentum
automation platform
Analog I/O bases
Accessories
Description Composition Type of
connection
Reference
Weight
kg
Terminal blocks Set of 3 connectors
1 row
Screw 170 XTS 001 00
Spring 170 XTS 002 00
Bus Bar 3 rows Screw 170 XTS 004 01
Spring 170 XTS 003 01
2 rows Screw 170 XTS 005 01
Spring 170 XTS 008 01
1 rows Screw 170 XTS 006 01
Spring 170 XTS 007 01
Cable Grounding
Rail
Used to connect the cable shielding CER 001
High vibration
environment clips
Used to prewire the I/O base units.
Requires screw or spring connection
terminals
170 BDM 090 00
Replacement parts
Description Use Reference
Weight
kg
Sheets of labels 10 front labels for Modicon Momentum
modules
170 XTS 100 00
Set of codingand
locating device
For screw or spring connection terminals 170 XCP 200 00
Dimensions, mounting
170 App
Rail or panel mounting
170 XTS 001 00
170 XTS 002 00
170 XTS 004 01
170 XTS 005 01
170 XTS 008 01
170 XTS 006 01
CER 001
(1)
107
125
93
141,5
47,5
62
125 60
(1)
(1) 2 holes for M4 screws, for panel mounting. (1) Equipment or enclosure.
Specications :
pages 29 to 33
Wiring diagrams :
pages 36 and 37
References (continued),
dimensions,
mounting
1
2
3
4
5
6
7
8
9
10
36
Modicon Momentum
automation platform
Analog I/O bases
Wiring diagrams for analog input bases and analog output bases
170 AAI 030 00 170 AAI 140 00
Example of external wiring of 2-wire sensor Example of external wiring of 2-wire sensor
Group of channels
Internal wiring
170 AAI 520 40 170 AAO 120/921 00
Example of external wiring of sensor Example of external wiring of 2-wire actuator
Group of channels Group of channels
Internal wiring Internal wiring
2
1
3
M-
InU8InU6InU5InU4InU2InU1 InU3 InU7
InI8InI6InI5InI4InI2InI1 InI3 InI7
Agnd8Agnd6Agnd5Agnd4Agnd2Agnd1 Agnd3 Agnd7
InI8InI6InI5InI4InI2InI1 InI3 InI7
L+
17161514121110 13987643251 18
171615141211
+
10 13987643251 18
+
+
U I
Return
Voltage input Current input
+ 24
Vdc
+ 24 Vdc
+
U
+
I
2
3
Inl1+
Inl2+
Inl3+
Inl4+
Inl5+
Inl6+
Inl7+
Inl8+
Inl9+
Inl10+
Inl11+
Inl12+
Inl13+
Inl14+
Inl15+
Inl16+
1
AGND
M
L
+
InU1+
InU2+
InU3+
InU4+
InU5+
InU6+
InU7+
InU8+
InU9+
InU10+
InU11+
InU12+
InU13+
InU14+
InU15+
InU16+
24 V
500 mA
fast-blow
fuse
Return
L+M–
+–
U
+–
U
+
U
2
3
L+M–
IS1+
RTD1+
RTD1
IS1
IS2+
RTD2+
RTD2
IS2
IS3+
RTD3+
RTD3
IS3
IS4+
RTD4+
RTD4
IS4
InU1+
InU1
InU2+
InU2
InU3+
InU3
InU4+
InU4
24 V
1
Return
500 mA
fast-blow
fuse
OutI1– 1L+1
1M–1
1M–1
1L+2
1M–2
1M–2
1L+3
1M–3
1M–3
1L+4
1M–4
1M–4
OutI1+
OutU1+
OutI2–
OutI2+
OutU2+
OutI3–
OutI3+
OutU3+
OutI4–
OutI4+
OutU4+
L+M-
+
+– +
2
3
L+M-
24 V
1
630 mA
fast-blow
fuse
Return
250 mA
fast-blow
fuse
Fuse 1
(2 A slow-blow)
Fuse 2
(2 A slow-blow)
Wiring diagrams
1
2
3
4
5
6
7
8
9
10
37
Modicon Momentum
automation platform
Analog I/O bases
Wiring diagrams for discrete and analog bases
170 AMM 090 00/AMM 090 01
Example of external wiring of 2-wire sensor Example of external wiring of 2-wire actuator
External bridge
Group of channels Group of channels
Internal wiring Internal wiring
170 AMM 090 00/AMM 090 01 (continued) 170 ANR 120 90/91
Example of external wiring of digital sensor/actuator Example of mixed discrete and analog I/O sensor/actuator eld wiring
Group of channels
Internal wiring
(1) c 24 V for 170 AMM 090 00, c 12 V for 170 AMM 090 01.
(2) Depending on application, max 5 A.
UI1–
I1+
UI2–
I2+
UI3–
I3+
UI4–
I4+
AGND
AGND
AGND
AGND
O1
O2
M
M
1L+M–
+
U
+
I
2
3
U1+
IS1
U2+
IS2
U3+
IS3
U4+
IS4
QV1
QI1
QV2
QI2
I 1
I 2
I 3
I 4
L+M–
(1)
1
(1)
325 mA
fast-
blow
fuse
Return
5 A
fast-
blow
fuse
UI1–
I1+
UI2–
I2+
UI3–
I3+
UI4–
I4+
AGND
AGND
AGND
AGND
O1
O2
M
M
1L+M–
+–
U
+–
I
2
3
U1+
IS1
U2+
IS2
U3+
IS3
U4+
IS4
QV1
QI1
QV2
QI2
I1
I2
I3
I4
L+M–
1
(1)
(1)
325 mA
fast-
blow
fuse
Return
5 A
fast-
blow
fuse
2-wire
actuator
2-wire
actuator
UI1–
I1+
UI2–
I2+
UI3–
I3+
UI4–
I4+
AGND
AGND
AGND
AGND
O1
O2
M
M
1L+M–
M
PE
1M
1L+
IN +PE OutPE
2
3
U1+
IS1
U2+
IS2
U3+
IS3
U4+
IS4
QV1
QI1
QV2
QI2
I1
I2
I3
I4
L+M–
1
(1)
(1)
3-wire actuator4-wire sensor
325 mA
fast-
blow
fuse
5 A
fast-
blow
fuse
1 A
fast-
blow
fuse
Return
2
3
M-AI6AI5AI4AI3AI2AI1I8I7I6I5I4I3I2I1 L+
17161514121110 13987643251 18
1M-A04A03A02A010807060504030201 1L+
171615141211
++
10 13987643251 18
1
Discrete input Nr.1
Discrete output Nr.5 Analog input Nr.1 Analog output Nr.4
- Return
- Return
Fuse (2)
+ 24 Vdc
+ 24 Vdc
+ 24 Vdc
DGnd AGnd
- Return
Fuse (2)
Fuse (2)
Wiring diagrams (continued)
1
2
3
4
5
6
7
8
9
10
38
Modicon Momentum
automation platform
Specialty module I/O bases
Product type
High-speed counter
Operating voltage 24 Vdc
Unique features 2 independent, high-speed (10 kHz-200 kHz) counters
Modularity Input channels 6 (3 per counter) True High Inputs
Output channels 4 (2 per counter) True High Outputs
Input specications Counter inputs 5 Vdc differential input, 200 kHz counter; 24 Vdc single-end input, 10 kHz counter
Discrete inputs
6 (2 x 3) 24 Vdc inputs:
- voltage range, - 3 to + 30 Vdc
- response time, 3 ms Off to On or On to Off
Output specications Counter outputs Two 5 Vdc differential outputs min 20 mA @ 24 Vdc
Discrete outputs
4 (2 per counter) 24 Vdc outputs:
- on current, 0.5 A per point, 1 A per counter
- response time: < 0.1 ms Off to On, < 0.1 ms On to Off
Protection
Surge Input voltage 45 V peak for 10 ms
Output current 5 A for 1 ms
Type of module 170 AEC 920 00
Pages 42
Selection guide
1
2
3
4
5
6
7
8
9
10
39
I/O with Modbus Master Base
120 Vac
RS 485 2- or 4-wire Modbus port
6 True High Inputs
3 True High Outputs
1 group of 6 inputs (120 Vac @47 to 63 Hz):
- voltage range, 0 to 132 Vac
- response time, < 12.3 ms @ 60 Hz On to Off,
< 12.5 ms @ 60 Hz Off to On
3 solid state switching outputs (120 Vac @47 to 63 Hz):
- on current, 0.5 A continuous per point, 1.5 A continuous per module
- response time: < 12.3 ms @ 60 Hz On to Off, < 12.5 ms @ 60 Hz Off to On
170 ADM 540 80
42
1
2
3
4
5
6
7
8
9
10
40
Modicon Momentum
automation platform
Specialty module I/O bases
Introduction
Modicon Momentum specialty module I/O bases provide support for unique
applications that broaden the range of the Modicon Momentum offering. The
specialty modules are: a 2-channel, High-speed counter module base -
170 AEC 920 00, and a 120 Vac, 6-point input/3-point output module base with a
Modbus communication port - 170 ADM 540 80.
High-speed counter
The 170 AEC 920 00 high-speed counter module base features 2 independent
counters, along with 6 discrete inputs and 4 discrete outputs.This base can connect
directly to either 5 Vdc differential or 24 Vdc single-ended encoders. The base
supports two operating modes:
b Incremental (up counter, down counter, and quadrature)
b Absolute (SSI up/down counter)
The high-speed counter module can be connected directly to many standard
communication networks – for communicating with programmable controllers,
industrial computers, and other controllers by installing one of the snap-on
Modicon Momentum communication adapters onto the base.
Input/Output module with Modbus communication port
The 170 ADM 540 80 input/output module base has 6 discrete inputs and 3 discrete
outputs for direct connection to 2- and 3-wire sensors and actuators, plus a Modbus
communication port for connection to serial devices.
This module can also be used as the I/O base for a programmable controller, in either
a stand alone or distributed I/O conguration, by installing one of the snap-on
Modicon Momentum M1 processor adapters.
Description
A specialty module I/O base consists of the following components:
1 Internal interface connectorfor the communication module
2 Locking and ground contact for the adapter
3 LED status display
4 Two connectors for the removable terminal blocks
5 Grounding screw
6 Grounding busbar mounting slot
7 Mounting holes for a panel mount
8 Protective cover for fuses (170 ADM 540 80) or connector for the removable
terminal block
Specications:
page 41
References:
page 42
Wiring diagrams:
page 43
Introduction,
description
1
2
3
4
5
6
7
8
9
10
41
Modicon Momentum
automation platform
Specialty module I/O bases
Specications
Model No. 170 AEC 920 00 170 ADM 540 80
Number of I/O Counter 2 independant
Inputs 2 x 3 discrete 1 x 6 discrete
Outputs 2 x 2 discrete 1 x 3 discrete
Discrete inputs
Operating voltage V24 DC 120 AC @ 47... 63 Hz
Input Range V- 3...+ 30 DC 0...132 AC
Surge V45 peak for 10 ms 200 AC for 1 cycle
Input current On mA 2.5 minimum 5.5 minimum
Off mA 1.2 maximum 1.9 maximum
Switching level V 11 DC minimum on voltage
5 DC maximum off voltage
79 AC minimum on voltage
20 AC maximum off voltage
Response time Off to on ms 3 < 12.5 @ 60 Hz
On to off ms 3 < 12.3 @ 60 Hz
Signal type True High
Discrete outputs Operating voltage V24 DC 120 AC @ 47 to 63 Hz
Signal type True High
On state voltage drop V< 0.5 DC @ 0.5 A current < 1.5 AC @ 0.5 A current
Fault sensing Overload and short circuit 1 fuse, 2.5 A @ 250 Vac
Current capacity A0.5 per point 0.5 continuous per point
A1 per counter
A2 per module 1.5 continuous per module
Current Leakage mA < 1 @ 24 Vdc 1.9 @ 120 Vac
Surge mA 5 A for 1 ms 30 minimum
Response time Off to on ms < 0.1 < 12.5 @ 60 Hz
On to off ms < 0.1 < 12.3 @ 60 Hz
Counter inputs Incremental counters Up counter, down counter, quadrature
Absolute SSI counter Up/down counter with 4 sub-modes
Input signals Vdc 5 differential input
24 single-ended input
Counter speed (max) kHz 200, differential inputs
10, single-ended inputs
Counter capacity 24 bits plus sign per counter
Counter conguration Via comm adapter (8 input words, 8 output
words)
Modbus port Type RS-485, 2- or 4-wire
Communication rates bit/s 19200 and 9600
Format 8-bit RTU / 7-bit ASCII
Modbus address range 0...247
Timeout ms 150 after transmission
Current consumption mA 280 125 @ 120 Vac
Agency approvals UL, e, CSA
References:
page 42
Wiring diagrams:
page 43
Specications
1
2
3
4
5
6
7
8
9
10
42
Modicon Momentum
automation platform
Specialty module I/O bases
References
Modules
Description Specications Reference Weight
kg
High-speed counter
Module Base
2 independent counters 170 AEC 920 00 0.210
I/O module base with
Modbus comm port
RS 485 Modbus port
6 inputs, 3 outputs
170 ADM 540 80 0.240
Replacement parts
Description Use Reference Weight
kg
Sheets of labels 10 front labels for
Modicon Momentum
modules
170 XTS 100 00
Documentation
Description Use Reference Weight
kg
Modicon Momentum I/O
bases
User guide for:
170 AEC 920 00
870 USE 008 00
170 ADM 540 80
870 USE 002 00
Accessories: Terminal blocks, bus bar, cable grounding rail and discrete input simulator, see
page 19.
170 AEC 920 00
170 ADM 540 80
Specications:
page 41
Wiring diagrams:
page 43
References
1
2
3
4
5
6
7
8
9
10
43
Modicon Momentum
automation platform
Specialty module I/O bases
Wiring diagrams
170 AEC 920 00
2-encoder and input/output eld wiring example
170 ADM 540 80
Modbus device and input/output eld wiring example
2
1
3
17161514121110 13987643251 18
M-I6I5I4I2I1 I302+Z2+B2+A2+01+Z1+B1+A1+ L+
1M-Q+Q3Q21L+1L+ Q102-Z2-B2-A2-01-Z1-B1-A1- 1L+
17161514121110 13987643251 18
ZM-1M-ZL+ZM- 1M-Z2*B2*A2*ZM-Z1* ZL+B1*A1* ZL+
17161514121110 13987643251 18
Encoder with
differential input
Encoder with
single ended
input
Discrete
output
Number 1
Discrete
input
Number 6
Counter 1 Counter 2 Counter control
inputs
Counter control
outputs
Fuse
Fuse
Fuse
+ 24 Vdc Power for module
- Return for module
+ 24 Vdc Power for inputs and outputs
- Return for inputs and outputs
+ 5 to 30 Vdc power for encoders
- Return for encoders
Specications:
page 41
References:
page 42
Wiring diagrams
PE
IN +PELN PE
GND
Tx Lo
Tx Hi
1L11N
1
2
3
Tx Lo
Tx Hi
Rx Lo
Rx Hi
GND N2N2N2N2NI6I5I4I3I2
Q3Q2
I1
Q1
L1
3-wire actuators 3-wire sensorsModbus Device
RS485
Return
a 120 V
Return
a 120 V
Return
a 120 V
2 A
slow- blow
fuse
Fuse 1 Option
200 mA
slow- blow
fuse
1
2
3
4
5
6
7
8
9
10
44
Modicon Momentum
automation platform
Communication adapters
Applications Communication adapters for Ethernet TCP/IP
Bus and network type Ethernet TCP/IP
Transparent Ready Class
A10 B20
Topology Physical interface IEEE 802.3 standard
Method of access CSMA-CD
Bit rate 10 Mbit/s 10/100 Mbit/s
Medium Type Twisted pair CAT5
Topology Star
Redundancy No
Maximum number of devices
64
Maximum length
1000 m per segment
Type of communicating module
170 ENT 110 02 170 ENT 110 01
Pages 49
Selection guide
1
2
3
4
5
6
7
8
9
10
45
Communication adapters for In t e r Bu s Communication adapter
for Probus DP bus
In t e r Bu s In t e r Bu s I/O bus Probus DP
SUPI 3 SUPI 2
DIN 19 258 standard EN 50170 standard
Master/Slave Master/Slave
500 Kbit/s 12 Mbit/s…9.6 Kbit/s
depending on length
Twisted pair Twisted pair
Ring Multi-drop, ring
No No
40 per installation remote bus module (up to 254 bus terminal
modules)
32 without repeater
126 with repeaters
12800 m 1200 m
170 INT 110 03 170 INT 110 00 170 DNT 110 00
49 59
1
2
3
4
5
6
7
8
9
10
46
Modicon Momentum
automation platform
Communication adapters
Applications Communication adapters for Modbus Plus network
IEC Data Format 984 Data Format
Bus and network type
Modbus Plus
Topology Physical interface
Modbus Plus
Method of access Token bus
Bit rate 1 Mbit/s
Medium Type Twisted pair
Topology Multi-drop
Redundancy No Yes No
Maximum number of
devices
Per segment
32
Overwall 64 (without repeaters)
Maximum length
5 000 m with repeaters
Type of communicating module
170 PNT 110 20
170 PNT 160 20 170 NEF 110 21
Pages 53
Communication adapters for Modbus Plus network
984 Data Format
Communication adapters for FIPIO bus
for TSX Series 7 and April 5000 for Modicon Premium PLCs
FIPIO
Modbus Plus Fip standard
Token bus Bus managed by bus arbitrator
1 Mbit/s 1 Mbit/s
Twisted pair
Multi-drop
Yes No
32
64 (without repeaters) 128
5 000 m with repeater 15 000 m with repeaters
170 NEF 160 21
170 FNT 110 00 170 FNT 110 01
53 55
Selection guide (continued)
1
2
3
4
5
6
7
8
9
10
47
Applications Communication adapters for Modbus Plus network
IEC Data Format 984 Data Format
Bus and network type
Modbus Plus
Topology Physical interface
Modbus Plus
Method of access Token bus
Bit rate 1 Mbit/s
Medium Type Twisted pair
Topology Multi-drop
Redundancy No Yes No
Maximum number of
devices
Per segment
32
Overwall 64 (without repeaters)
Maximum length
5 000 m with repeaters
Type of communicating module
170 PNT 110 20
170 PNT 160 20 170 NEF 110 21
Pages 53
Communication adapters for Modbus Plus network
984 Data Format
Communication adapters for FIPIO bus
for TSX Series 7 and April 5000 for Modicon Premium PLCs
FIPIO
Modbus Plus Fip standard
Token bus Bus managed by bus arbitrator
1 Mbit/s 1 Mbit/s
Twisted pair
Multi-drop
Yes No
32
64 (without repeaters) 128
5 000 m with repeater 15 000 m with repeaters
170 NEF 160 21
170 FNT 110 00 170 FNT 110 01
53 55
1
2
3
4
5
6
7
8
9
10
48
Modicon Momentum
automation platform
Ethernet TCP/IP communication adapters
Introduction
The Model 170 ENT 110 02 and 170 ENT 110 01 Ethernet communication adapters
for the Modicon Momentum I/O product line provide a direct connection to
Ethernet-based networks for the entire family of Modicon Momentum I/O modules.
This connectivity enables communications with a full range of Ethernet TCP/IP
compatible control products that includes: programmable controllers, industrial
computers, motion controllers, operator control stations, host computers, and other
controls. This communication network provides a exible, cost-effective solution for
communicating factory oor information to various layers of an integrated
manufacturing facility.
The 100BASE-TX Ethernet communication adapter, the 170 ENT 110 01 (and the
10BASE-T adapter, the 170 ENT 110 02) are single adapters designed to plug on to
any of the Modicon Momentum Input/Output module bases. Both are designed to
conform to the requirements of the Ethernet communication network.
The Ethernet IP addressing scheme allows an unlimited number of Modicon
Momentum I/O modules or wiring diagrams on the network. Using standard Ethernet
hubs, routers, and bridges, the performance and distance capability of the Ethernet
network can be tailored to meet the requirements of almost any control application.
The Ethernet communication adapter uses the standard Modbus message
structure and control commands over the TCP/IP protocol. This simplies
implementation by control engineering, while providing information that can be
communicated over standard network media to enterprise applications.
Since Modbus on TCP/IP over Ethernet is supported by Schneider Electric’s
Modicon Quantum and Premium controller families, Modicon Momentum I/O can
be added to existing control systems where additional I/O capacity of a distributed
I/O sub-network is needed.
The Ethernet communication adapter requires connection to a BOOTP server for
conguring the module’s IP parameters, including its own unique IP address, default
gateway, and sub-net mask. These parameters are stored in the communication
adapter’s ash memory. Schneider Electric automation business offers BOOTP Lite
Ethernet software as a free download from the Schneider Electric web site at
www.schneider-electric.us.
Description
The front panel of the 170 ENT 110 0p Ethernet communication adapter features:
1 Ethernet RJ45 connector for 100BASE-TX interface for 170 ENT 110 01) or
10BASE-T interface for 170 ENT 110 02)
2 Area for Label (label shipped with I/O base)
3 LED Status Indicators for the 170 ENT 110 02 display include:
Run (green), module health-
LAN Active (green), Ethernet network status-
LED Status Indicators for the 170 ENT 110 01 display include:
Run (green), module health-
10T (green), 10 Mbit/s network activity-
100T (amber), 100 Mbit/s network activity-
ST (green), Ethernet network status-
3
2
1
Introduction,
description
1
2
3
4
5
6
7
8
9
10
49
Modicon Momentum
automation platform
Ethernet TCP/IP communication adapters
Specications
Model No 170 ENT 110 02 170 ENT 110 01
Communication network Ethernet TCP/IP
Media Shielded twisted pair cable
Communication rate Mbit/s 10 10/100
Distance m (ft) 100 (328) per segment
Connectors RJ45, 10BASE-T RJ45, 100BASE-TX
Transparent Ready services Class A10 B20
Standard Web server “Rack Viewer” access to the product
description and status and to base unit
diagnostics
“Data editor” access to the conguration
functions and variables
Standard Ethernet TCP/IP
communication services
Modbus Messaging (read/write data words)
FDR client for automatic assignment of
the IP address and network parameters
SNMP agent, detection of the product by
an SNMP manager
adapter conguration BOOTP server to assign IP parameters
Flash memory 128 K for IP parameter storage
Error checking CRC-32 error check
Error and fail states Fail safe
Addressing Unique IEEE global address, IP address user assigned
Mode of operation Master slave, peer-to-peer
Topology Multi-drop bus, star
Packaging Standard Modicon Momentum communications adapter enclosure - IP 20
environment
Indicator lights Run and activity lights Run, 10 Mbit/s, 100 Mbit/s, and status lights
Power source Power supply on-board the I/O base
Hot swapping of modules Yes
Agency approvals UL, e, CSA, FM Class I, Div. II UL, e, CSA
References
Communication adapters
Description Communication rate
Transparent Ready Class
(1)
Reference Weight
kg
Ethernet TCP/IP
communication adapters
10 Mbit/s
A10
170 ENT 110 02 0.070
10/100 Mbit/s
B20
170 ENT 110 01 0.070
Accessories
ConneXium cabling
system
See page 76
BOOTP Lite Ethernet Software
Download from
www.schneider-electric.us
Ethernet TCP/IP
communication adapter user guide
See page 103
(1) Transparent Ready Class A10 and B20, for more details, consult our catalog “Transparent
Ready, Ethernet TCP/IP and Web technologies”
Specications,
references
170 ENT 110 02
1
2
3
4
5
6
7
8
9
10
50
Modicon Momentum
automation platform
Modbus Plus communication adapters
Introduction
Modbus Plus communication adapters for the Modicon Momentum I/O product
line can be plugged into any Modicon Momentum I/O base to create a functional I/O
unit on the Modbus Plus bus…and to provide a direct connection to the Modbus Plus
Network for the full family of Modicon Momentum I/O modules. This connectivity
enables communications with Modbus Plus compatible control products – including:
programmable controllers, industrial computers, operator control stations, drive
systems, and other controls and provides a exible, cost-effective solution for
distributing I/O modules throughout a large area. To expand the capabilities of the
Modbus Plus Network for distributed I/O applications, the communication adapters
have been designed to permit up to 64 Modicon Momentum I/O modules to be
connected to the network without the need for signal repeaters.
Each Modicon Momentum I/O module is an individual node on the Modbus Plus
network with its address user-selected on the dual rotary switch on the front of the
communication adapter. The Modicon Momentum I/O modules can be congured for
the network, and assigned program reference numbers, by using either the Peer
Cop function, the MSTR function block instruction in the programmable controller,
or the Modbus Plus conguration in an industrial computer.
There are four types of communication adapters available:
170 PNT 110 20, Single Port, IEC Data Format
170 PNT 160 20, Redundant Port, IEC Data Format
170 NEF 110 21, Single Port, 984 Data Format
170 NEF 160 21, Redundant Port, 984 Data Format
IEC Data Format
This version of the Modicon Momentum Modbus Plus communication adapter
communicates I/O data to the programmable controller in the IEC data format, which
has bit numbering 0 through 15, right to left, within the data word (i.e., input or output
number 1 is bit number 0).
984 Data Format
This version of the Modicon Momentum Modbus Plus communication adapter
communicates I/O data to the programmable controller in the traditional 984 data
format, which has bit numbering 1 through 16, left to right, within the register (i.e.,
input or output number 1 is bit number 1).
Since Modbus Plus is supported by the Modicon Quantum and 984 controller
families, Modicon Momentum I/O can be added to existing control systems where
additional I/O capacity or a distributed I/O sub-network is needed.
Introduction
1
2
3
4
5
6
7
8
9
10
51
Modicon Momentum
automation platform
Modbus Plus communication adapters
Description
Each 170 PNT/NEF communication module is comprised of:
1 Three indicator lights (LEDs):
- MB + ACT indicator light (green) : module powered up or communicating
- ERR A indicator light (red) : detected communication error network A
- ERR B indicator light (red) : detected communication error network B
(for redundant model)
2 A 9-way male SUB-D connector for connecting to the Modbus Plus network
3 A 9-way male SUB-D connector for a redundant Modbus Plus network
4 A slot for an identication label (supplied with I/O sub-bases)
5 Two switches for coding the slave address on the bus
Specications
Type of module 170 PNT 110 20 170 PNT 160 20 170 NEF 110 21 170 NEF 160 21
Communication network Modbus Plus
Master PLC on the network Modicon Quantum,
Modicon Premium
Modicon Quantum Modicon Quantum, Compact 984
Structure Type Industrial
Redundancy No Yes No Yes
Topology Multi-drop, devices connected using extension cable or tap-off cable
Length 5,000 m (6000 ft) maximum with repeaters
Access method Token bus
Transmission Bit rate 1 Mbit/s
Medium Twisted pairs
Data Format IEC Data Format 984 Data Format
Number of Modicon
Momentum devices
Per segment 31 connection points
Maximum 63 connection points
Power source Power supply on-board the I/O base
Behavior in the event of a detected communication error Discrete I/O : forcing to state 0
Analog I/O : congurable (maintain value, fallback to 0 or full scale value)
Services Conguration : Peer cop and MSTR function block, “peer-to-peer” mode
Agency approvals UL, e, CSA, FM Class I, Div. II UL, e, CSA
3 1 2
45
References :
page 53
Description,
specications
1
2
3
4
5
6
7
8
9
10
52
Modicon Momentum
automation platform
Modbus Plus communication adapters
Network topology
Modicon Momentum I/O modules in a distributed control system
Modicon Momentum I/O modules with Modbus Plus double cable in a
distributed and redundant control system
1 140 CRA 211 10: Modicon Quantum Modbus Plus drop interface and power
supply, single-cable support, 115/230 Vac
2 140 NOM 212 00: Modicon Quantum Modbus Plus head-end interface, redundant
support, twisted pair cable
3 140 NOM 252 00: Modicon Quantum Modbus Plus Head-end Interface, single-
cable support, ber optic cable
4 170 PNT 110 20 or 170 NEF 110 21: Modicon Momentum Modbus Plus
communication adapter, non-redundant network
5 170 PNT 160 20 or 170 NEF 160 21: Modicon Momentum Modbus Plus
communication adapter, redundant network
6 416 NHM 212 33: Modbus Plus type III PCMCIA Card, single port ; or
416 NHM 212 34: Modbus Plus type III PCMCIA Card, single port, “plug and play”
7 990 NAD 230 00: Modbus Plus tap, IP 20
8 990 NAD 230 10: Modbus Plus tap, IP 65
9 990 NAD 211 10/30: Modbus Plus drop cable (lengths: 2 or 4 or 6 m)
10 990 NAD 215 10: Modbus Plus ruggedized tap programming Cable, 3.05 m
11 170 MCI 020/021pp: Modbus Plus RJ45 cable (lengths: 0.25 , 1 , 3 or 10 m)
12 170 XTS 020 00: Modbus Plus “T” connector (DB9 base)
13 490 NAA 271 0p: Standard Modbus cable (lengths: 30, 150, 300, 450 or 1500 m)
14 990 NAD 230 11: Modbus Plus ruggedized tap terminators
15 170 XTS 021 00: Modbus Plus RJ45 terminator
16 416 NHM 300 32: Modbus Plus PCI PC adapter Card, dual ports
Specications :
page 51
References :
page 53
19
6
10
8
DIO
11
12
4
15
7 13
Cabling system
2
14
55 9
16
9
7
1
3
8
1
2
3
4
5
6
7
8
9
10
53
Modicon Momentum
automation platform
Modbus Plus communication adapters
References
Description Connection Item
(1)
Bus master
PLC
Reference
Weight
kg
Communication adapters
for Modicon Momentum
I/O sub-bases
Non-redundant Modbus Plus network 4Modicon
Premium,
Modicon
Quantum
170 PNT 110 20
Compact 984
170 NEF 110 21
Redundant Modbus Plus network 5Modicon
Quantum
170 PNT 160 20
Compact 984 170 NEF 160 21
Description Use Mounting
on
Item
(1)
Reference
Weight
kg
Modbus Plus taps IP 20 junction box
for tap-off connection “T”
7990 NAD 230 00 0.230
IP 20 junction box
for tap-off connection “T”,
connection of cable on screw terminal
block with one RJ45 connector in front
DIN prole 990 NAD 230 20
Panel 990 NAD 230 21
Modbus Plus Tap (IP 20),
standard Modbus cable
with one RJ45 connector in front
Panel 8990 NAD 230 10 0.650
IP 20 “T” with 2 RJ45 connectors for
Modbus cable and one 9-way SUB-D
connector for tap link devices
12 170 XTS 020 00 0.260
Terminator connector kit
(set of 2)
2 impedance adaptors for box (IP 20)
990 NAD 230 20/21
1990 NAD 230 22
2 impedance adaptors for box (IP 20)
990 NAD 230 10
14 990 NAD 230 11
2 impedance adaptors for tee (IP 20)
170 XTS 020 00
15 170 XTS 021 00
Connection cables
Description Use Item
(1)
Length Reference
Weight
kg
From To
Standard Modbus Plus
cables
T-junction box
990 NAD 230 00,
990 NAD 230 11
T-junction box
990 NAD 230 00,
990 NAD 230 11
13 30 m 490 NAA 271 01
150 m 490 NAA 271 02
300 m 490 NAA 271 03
450 m 490 NAA 271 04
1500 m 490 NAA 271 06
Modbus Plus cable for
RJ45
“T” 170 XTS 020 00 “T” 170 XTS 020 00 11 0.25 m 170 MCI 021 10
1 m 170 MCI 021 36
3 m 170 MCI 021 20
10 m 170 MCI 021 80
Modbus Plus Drop cables Communication
modules
for Modicon
Momentum I/O
sub-bases
170 PNT/NEF
T- junction box
990 NAD 230 00/10
92.4 m 990 NAD 211 10
6 m 990 NAD 211 30
Description Use Length Reference
Weight
kg
From junction box To equipment, cable outlet
of 9-way SUB-D type connectors
Modbus Plus Drop Cable Flying leads Left side 2.4 m 990 NAD 218 10
6 m 990 NAD 218 30
Right side 2.4 m 990 NAD 219 10
6 m 990 NAD 219 30
Connecting accessories
Description Use for Reference
Weight
kg
RJ45 Crimp tool Crimping the RJ connectors 490 NAB 000 10
9-way female SUB-D
connector
Communication module connection AS MBKT 085
Wiring tool Fitting trunk cables and drop cables in local site tap 043 509 383
Other connection accessories See page 75
(1) Item, see page 52.
170 PNT 110 20/NEF 110 21
170 PNT 160 20/NEF 160 21
AS MBKT 085
Specications :
page 51
References
1
2
3
4
5
6
7
8
9
10
54
Modicon Momentum
automation platform
FIPIO communication adapters
Introduction
The FIPIO™ communication adapter can be plugged into a Modicon™ Momentum
I/O base to create a functional I/O unit on the FIPIO bus, and to provide a direct
connection to the FIPIO Network for the full family of Modicon Momentum I/O modules.
This connectivity enables the Modicon Momentum I/O to be used along with other
FIPIO compatible control devices, including: industrial computers, operator control
stations, drive systems, and other controls to provide a exible, time-critical,
cost-effective solution for distributing I/O modules throughout a large area.
There are two types of communication adapters available:
170 FNT 110 01 (1) for a FIPIO bus connected to a Modicon Premium PLC
170 FNT 110 00 for a FIPIO bus connected to TSX 7 series CPUs or APRIL 5030
and 5130 CPUs
Each Modicon Momentum I/O module is an individual node or device on the FIPIO
network with its address set by the user on the dual rotary switch on the front of the
communication adapter. FIPIO is a network that can have up to 128 slave devices.
The FIPIO network’s distance and communication capabilities range from 1000 meters
(3330 ft.) to 15000 meters (45000 ft) with repeaters over twisted pair cable at a data
rate of 1 Mbit/s.
(1) The FIPIO communication adapter 170 FNT 110 01 does not support the 170 ADM 540 80
I/O base.
Description
The 170 FNT 110 0p communication module features the following:
1 Three indicator lights (LEDs):
Ready indicator light (green): module powered up or in service-
COM indicator light (yellow): data being sent or received-
ERR indicator light (red): inoperative device-
2 9-way male SUB-D connector for connecting to FIPIO bus
3 Slot for identication label (supplied with I/O sub-bases)
4 Two switches for coding slave address on the bus
4 3
21
Introduction,
description
Modicon
Momentum
I/O modules
Third-party products
Modicon Momentum I/O modules
Modicon PremiumPLC
Bus FIPIO
Magelis HMI
1
2
3
4
5
6
7
8
9
10
55
Modicon Momentum
automation platform
FIPIO communication adapters
Specications
Type of module 170 FNT 110 01 170 FNT 110 00
Communication bus FIPIO
Bus manager PLC Premium TSX Series 7, model 40 or April 5000
Structure Type Open industrial, conforming to the WorldFip standard
Topology Devices connected using extension cable or tap-off cable
Length meters 1,000 to 5,000 depending on the medium used
Access method Producer/consumer principle, managed by a bus arbiter
Transmission Bit rate 1 Mbit/s
Media Shielded twisted pair cable 150 W. Fiber optic 62.5/125 or 50/125 with electrical/optical
repeaters
Number of Modicon
Momentum devices
Per segment 31 connection points (without repeater)
Maximum 97 connection points 61 connection points
Behavior in the event of a detected communication error Discrete I/O: forcing to state 0
Analog I/O: congurable (maintain value, fallback to 0 or full scale value)
Other specications, consult our catalog Premium automation platform
Agency approvals UL, e, CSA
References
Description Connection Bus manager PLC Reference Weight
kg
Communication
adapters for
Modicon
Momentum
I/O sub-bases
FIPIO eldbus on
Modicon Momentum
I/O
sub-bases
Modicon Premium
170 FNT 110 01 (1) 0.110
TSX Series 7,
Model 40,
April 5000
170 FNT 110 00 0.110
Description Connection Material Reference Weight
kg
Female connectors
(9-way SUB-D)
On 170 FNT 110 0p
communication
module
Black polycarbonate
IP 20
TSX FP ACC 12 0.040
Zamac
TSX FP ACC 2 0.080
Bus connection
boxes
Main tap-off cable Black polycarbonate
IP 20
TSX FP ACC 14 0.120
Zamac IP 65
TSX FP ACC 4 0.660
Description Composition Length Reference Weight
kg
Tap-link cables 8 mm, 2 shielded
twisted pair 150 W
100 m TSX FP CC 100 5.680
200 m TSX FP CC 200 10.920
500 m
TSX FP CC 500 30.000
Other connection
accessories Consult our catalog
“Premium
automation platform”
FIPIO
Communication
adapter User Guide
See page 102
(1) Does not support the 170 ADM 540 80 I/O base.
170 FNT 110 01/00
TSX FP ACC 12
TSX FP ACC 14
TSX FP ACC 4
Specications,
references
1
2
3
4
5
6
7
8
9
10
56
Modicon Momentum
automation platform
In t e r Bus communication adapters
Introduction
The InterBu s communication adapter for the Modicon MomentumI/O product
line provides a direct connection to the In t e r Bu s Network for the full family of
Modicon Momentum I/O modules. This connectivity enables Modicon Momentum
I/O to be used in open architecture control systems that utilize either a
programmable controller or industrial computer as the network master. In these
applications, In t e r Bu s serves as the communication network that connects Modicon
Momentum I/O modules, along with other In t e r Bu s compatible control devices, for
the communication of input and output information with a single master controller.
There are two types of In t e r Bu s adapters available:
170 INT 110 00, twisted pair media, SUPI 2
170 INT 110 03, twisted pair media, SUPI 3, supports G4 diagnostic
The InterBu s communication adapter is designed to plug on to any of the Modicon
Momentum Input/Output module bases, thus allowing the I/O module to be accessed
over the In t e r Bu s Communication Network. Each Modicon Momentum I/O module is
an individual node or device on the In t e r Bu s network with its address set either by its
physical location on the network, or by menu-driven software that is available with
some In t e r Bu s master devices. In t e r Bu s is a cost-effective method of distributing
I/O modules throughout large plant areas. The gure below illustrates a typical
control system using Modicon Momentum I/O modules on the In t e r Bu s network, with
a Quantum PLC programmable controller as the network master.
Network Topology
Description
The 170 INT 110 0p In t e r Bu s communication adapters feature the following on the
front panel:
1 Two 9-Pin SUB-D connectors for connection to the In t e r Bu s bus
2 Area for Label (label shipped with I/O base)
3 LED Status Indicators for 170 INT 110 0p include:
UL (green), logic power check (- 170 INT 110 03 only)
BA (green), bus enabled-
RC (green), remote bus check-
RD (yellow), remote bus disabled-
1
3 2
Introduction,
description
12345678910 11 12 13 14 15 16 1234567891011 12 13 14 15 16 12345678910 11 12 13 14 15 16
CPS 114 20
140
Xxxx Ixxx
CPU 343 00
140
Xxxx Ixxx
xxx xxx 00
140
Xxxx Ixxx
DDO 334 00
140
Xxxx Ixxx
xxx xxx 00
140
Xxxx Ixxx
xxx xxx 00
140
Xxxx Ixxx
12345678910 11 12 13 14 15 16
12345678910 11 12 13 14 15 16 1 2345678910 11 12 13 14 15 16
Modicon Quantum
PLC with
140 NOA 622 00
In t e r Bu s module
Modicon Momentum I/O Modules
Third
Party
Products
Remote Bus Extension
Remote Bus Extension
Branch
Interface
ModiconMomentum I/O Modules
Remote Bus Remote Bus Remote BusRemote Bus
Remote Bus
Modicon Momentum I/O Modules
1
2
3
4
5
6
7
8
9
10
57
Modicon Momentum
automation platform
In t e r Bus communication adapters
Specications
Model No. 170 INT 110 00 170 INT 110 03
Communication network In t e r Bu s , I/O b u s In t e r Bu s
Communication rate Kbit/s 500
Number of nodes (devices) Up to 254 devices
Media Twisted Pair
Distance m (ft) Up to 12 800 (41 984 ft), 400 (1312 ft) between two nodes
Connectors 2-9 Pin “D” connectors
Error checking CRC-16 error check
Error and fail states Fail safe
Addressing Physical location or software
Mode of operation Master-Slave, continuous shift register
Topology Ring
In t e r Bu s generation SUPI 2 SUPI 3
Packaging Standard Modicon Momentum communication adapter enclosure - IP 20
environment
Indicator lights Diagnostic and status light standard
Power source Power supply on board the I/O base
Agency approvals UL, e, CSA, FM Class I, Div. II
References
Modules
Description Media Generation Reference Weight
kg
In t e r Bu s communication
adapters
Twisted Pair SUPI 2 170 INT 110 00 0.070
SUPI 3 170 INT 110 03 0.070
Accessories
Description Length Reference Weight
kg
Branch In t e r face, Twisted Pair, SUPI 3 170 BNO 671 01
In t e r Bu s Connector Kit, sockets/pins, 9-pin with
male and female connectors for remote bus cable
170 XTS 009 00
In t e r Bu s Cable (with small connectors) 11 cm
(0.36 ft)
170 MCI 007 00
In t e r Bu s Cable low-prole connector 100 cm
(3.3 ft)
170 MCI 100 01
In t e r Bu s cables 100 m
(330 ft)
TSX IBS CA 100
400 m
(1312 ft)
TSX IBS CA 400
By the meter KAB 3225 LI
Modicon Momentum front label replacement
(set of 10)
170 XCP 100 00
In t e r Bu s User Guide See page 103
170 INT 110 00/110 03
Specications,
references
1
2
3
4
5
6
7
8
9
10
58
Modicon Momentum
automation platform
Probus DP communication adapters
Introduction
The Model 170 DNT 110 00 Probus DP communication adapter for the Modicon
Momentum I/O product line provides a direct connection to the Probus DP
Communication Network for the full family of Modicon Momentum I/O modules. This
connectivity enables the Modicon Momentum I/O to be used in open architecture
control systems with other Probus DP compatible control products, including:
programmable controllers, industrial computers, operator control stations, drive
systems, and other controls to provide a exible, cost-effective solution for
distributing I/O modules throughout a large area.
The Probus DP communication adapter is a single package that is designed to plug
on to any of the Modicon Momentum Input/Output modules base, thus allowing the
I/O module full access to the Probus DP Communication Network. Each Modicon
Momentum I/O module is an individual node on the network, with its address
user-selected on the dual rotary switch on the front of the communication adapter.
The gure below illustrates a typical control system using Modicon Momentum I/O
modules on the Probus DP network with programmable controllers and industrial
computer systems.
The Probus Conguration File is required for the conguration of the Modicon
Momentum I/O Modules on the Probus DP network. This le contain the Probus
PNO “Identnumber” for Modicon Momentum I/O modules, and is available at
no charge to users as a download over the Internet from the Schneider Electric
web page.
Network Topology
Description
The front panel of the 170 DNT 110 00 Probus DP Communication adapter is
comprised of:
1 LED Status Indicators comprising: BF (green), detected bus fault
2 A 9-Pin SUB-D connector for connection to the Probus DP Network
3 Area for Label (label shipped with I/O base)
4 Rotary switches for slave addresses
Introduction,
description
123456789101112 13 14 15 16 1234567891011 12 13 14 15 16 12345678910 11 12 13 14 15 16
Controller with
Network Interface Module
Controller with
Network Interface Module
Computer with
Network Interface Module
Modicon Momentum I/O Modules Third party products
3
4
1 2
1
2
3
4
5
6
7
8
9
10
59
Modicon Momentum
automation platform
Probus DP communication adapters
Specications
Model No. 170 DNT 110 00
Communication bus Probus DP
Communication rate 9.6 Kbit/s…12 Mbit/s
Number of nodes (devices) Up to 126 devices (32 without repeater)
Media Twisted Pair
Distance m (ft) Up to 1 200 (4 000)
Connectors 9 Pin “D” connectors
Error checking CRC-16 error check
Error and fail states Fail safe
Addressing Switch selectable
Mode of operation Master-Slave
Topology Multi-Drop, Ring
Packaging Standard Modicon Momentum commmunications adapter enclosure - IP20
environment
Indicator lights Diagnostic and status light standard
Power source Power supply on-board the I/O base
Agency approvals UL, e, CSA
References
Module
Description Reference Weight
kg
Probus DP Communication adapter
170 DNT 110 00 0.070
Accessories
Description Length Reference Weight
kg
Device Master File (1)
Probus DP cable 100 m (328 ft) TSX PBS CA 100
400 m (1312 ft) TSX PBS CA 400
By the meter KAB PROFIB
Probus DP connector with Terminator 490 NAD 911 03
Probus DP in-Line Connector 490 NAD 911 04
Probus DP connector with Programming
Port
490 NAD 911 05
Modicon Momentum front label replacement
(set of 10)
170 XTS 100 00
Probus DP User Guide See page 103
(1) The Probus device Master File (381 SWA 000 00) is supplied with the User Guide
870 USE 004 0p, or can be downloaded from the Schneider Electric website at
www.schneider-electric.us.
170 DNT 110 00
Specications,
references
1
2
3
4
5
6
7
8
9
10
60
Modicon Momentum
automation platform
M1/M1E processor adapters
Type
M1 processor adapters
RAM memory
64 Kbit 256 Kbit
Flash memory
256 Kbit
984 LL program memory
2.4 Kbit 12 Kbit
IEC program memory
160 Kbit
Data memory
2 Kbit 4 Kbit
Scan time
1 ms/K 0.63 ms/K 1 ms/K 0.63 ms/K
Clock speed
20 MHz 32 MHz 20 MHz 32 MHz
I/O points
2048 4096
I/O drops
Up to 2048 I/O points with Modbus Plus option adapter 80 with ProWORX
128 with Concept
Power source
Power supply on-board the I/O bases
Communication ports
1 RS 232 Modbus 1 RS 232 Modbus
1 RS 485 Modbus
1 RS 232 Modbus
1 I/O bus
IEC executive
Compatible
Type of module
171 CCS 700 00 171 CCS 700 10 171 CCS 780 00 171 CCS 760 00
Pages 68
M1 processor adapters M1E processor adapters
512 Kbit 544 Kbit
512 Kbit 512 Kbit 1 Mbit 512 Kbit 1 Mbit
18 Kbit
240 Kbit 200 Kbit 200 Kbit
24 Kbit
1 ms/K 0.3 ms/K
32 MHz 50 MHz
8192
Up to 2048 I/O points
with
Modbus Plus option
adapter
80 with ProWORX
128 with Concept
Up to 2048 I/O points with
Modbus Plus option adapter
80 with ProWORX
128 with Concept
Power supply on-board the I/O bases
1 RS 232 Modbus
1 RS 485 Modbus
1 RS 232 Modbus
1 I/O bus
1 Ethernet (Transparent Ready class B10 )
1 RS 485 Modbus
1 Ethernet (Transparent Ready class B10 )
1 I/O bus
Compatible Supplied Supplied
171 CCC 780 10 171 CCC 760 10 171 CCC 980 20 171 CCC 980 30 171 CCC 960 20 171 CCC 960 30
68
Selection guide
1
2
3
4
5
6
7
8
9
10
61
M1 processor adapters M1E processor adapters
512 Kbit 544 Kbit
512 Kbit 512 Kbit 1 Mbit 512 Kbit 1 Mbit
18 Kbit
240 Kbit 200 Kbit 200 Kbit
24 Kbit
1 ms/K 0.3 ms/K
32 MHz 50 MHz
8192
Up to 2048 I/O points
with
Modbus Plus option
adapter
80 with ProWORX
128 with Concept
Up to 2048 I/O points with
Modbus Plus option adapter
80 with ProWORX
128 with Concept
Power supply on-board the I/O bases
1 RS 232 Modbus
1 RS 485 Modbus
1 RS 232 Modbus
1 I/O bus
1 Ethernet (Transparent Ready class B10 )
1 RS 485 Modbus
1 Ethernet (Transparent Ready class B10 )
1 I/O bus
Compatible Supplied Supplied
171 CCC 780 10 171 CCC 760 10 171 CCC 980 20 171 CCC 980 30 171 CCC 960 20 171 CCC 960 30
68
1
2
3
4
5
6
7
8
9
10
62
Modicon Momentum
automation platform
M1/M1E processor adapters
Introduction
Modicon Momentum M1/M1E processor adapters are based on the Modicon 984
family of products. You can mount these adapters on Modicon Momentum I/O Bases
to provide intelligence to the I/O. The processor adapter can quickly and
independently solve logic, control its own local I/O (discrete or analog), and
communicate to other control entities through one of a number of Modicon
Momentum communication options. The processor adapter can turn an ordinary I/O
Base into a PID controller or high-speed logic solver.
You can create your own controller from a number of different bases, and with other
Modicon Momentum options, network your local logic solvers together into an
intelligent subsystem as part of a larger Modicon application, or into a stand alone,
integrally networked system with local controllers with extended I/O.
Modicon Momentum M1/M1E processor adapters can stand alone, or be mounted
on a single Modicon Momentum I/O Base (with its own extended Modicon
Momentum I/O connected to the I/O Bus Port on 171 CCS 760 00 processor
adapter). It can also be mounted together with one of a variety of Modicon
Momentum Option adapters – providing different network capabilities, a time-of-day
clock, and a battery back-up system. The built-in ash memory is used to store the
executive, allowing for convenient eld upgrades of the operating system. The ash
memory can also be used to back up your applications, creating a local copy of your
program to be loaded back into RAM, thus providing original program le integrity.
On the 171 CCS 780 00 processor adapter, the RS 485 port can be used to connect
to dedicated devices such as an operator interface panel or a marquee, or used in a
master/slave RS 485 network to connect to multiple devices.
The processor adapters can be programmed with Modsoft version 2.5 or greater,
Concept version 2.1 or greater, ProWORX NxT version 2.0 or greater or
ProWORX 32.
The following table describes the specications of the Modicon Momentum M1/M1E
processor adapters.
Specications
Processor adapter RAM Memory Flash Memory Scan Time Modbus Port I/O Bus Port IEC Executive
171 CCS 700 00 64 K 256 K 1 ms/K 1 x RS 232C
171 CCS 700 10 64 K 256 K 0.63 ms/K 1 x RS 232C
171 CCS 760 00 256 K 256 K 0.63 ms/K 1 x RS 232C 1 x I/O Bus Compatible
171 CCS 780 00 64 K 256 K 1 ms/K 1 x RS 232C
1 x RS 485
171 CCC 760 10 512 K 512 K 1 ms/K 1 x RS 232C 1 x I/O Bus Compatible
171 CCC 780 10 512 K 512 K 1 ms/K 1 x RS 232C
1 x RS 485
Compatible
171 CCC 960 20 544 K 512 K .3 ms/K 1 x Ethernet 1 x I/O Bus
171 CCC 960 30 544 K 1 Mb .3 ms/K 1 x Ethernet 1 x I/O Bus Supplied
171 CCC 980 20 544 K 512 K .3 ms/K 1 x RS 485
1 x Ethernet
171 CCC 980 30 544 K 1 Mb .3 ms/K 1 x RS 485
1 x Ethernet
Supplied
Programming Software for Modicon Momentum
Modicon Momentum processor adapters have a number of PC programming
software options available. You can program your processor adapter via the
Modbus RS 232 serial port, or with an M1E processor via Ethernet network.
If using a Modbus Plus Option adapter in conjunction with a Processor adapter, you
can program via an SA85 card installed in a PC and connected to the same
Modbus Plus network.
For more specic information, see the appropriate Modicon Momentum, ProWORX
or Concept programming software literature and documentation.
Introduction
Specications:
pages 64 to 67
References:
page 68
1
2
3
4
5
6
7
8
9
10
63
Modicon Momentum
automation platform
M1/M1E processor adapters
Description
A typical Modicon Momentum M1/M1E Processor adapter consists of the
following components:
1 Modbus or Ethernet Port connector
2 Optional second port (Modbus or I/O bus)
3 LED indicators
4 Fill-in Label
Mounting
A typical system, showing a model 171 CCS 760 00 Modicon Momentum M1
processor adapter mounted on top of a Modicon Momentum I/O Base. The
processor adapter controls the I/O it is mounted on, the local I/O, and can control
externally congured I/O. You can also use a Modbus Plus Option adapter with the
processor adapter to extend the system’s I/O capacity.
12
34
Specications:
pages 64 to 67
References:
page 68
Description
1
2
3
4
5
6
7
8
9
10
64
Modicon Momentum
automation platform
M1/M1E processor adapters
Environment
Type of processor 171 CCS 700 00 171 CCS 700 10 171 CCS 780 00 171 CCS 760 00
Temperature Operating °C 0...60
Storage °C - 40...85
Relative humidity 5...96% (non-condensing)
Altitude m 2000 (6,500 ft.)
Mechanical withstand
(immunity)
To vibrations 57...150 Hz @ 1 gn
10...57 Hz @ 0.075 mm d.a
To shocks
±
15 gn peak, 11 ms, half sine wave
Designed to meet UL, e, CUL, FM Class 1 Div. 2, NEMA 250 Type 1, and IP 20 conforming to IEC 529
Specications
Central processing unit (CPU) x 86 based
Word length bit 16
Material Lexan
Voltage Vdc 5.0 V (supplied by I/O Base)
Voltage tolerance
±
5% (as supplied by I/O Base)
RFI immunity/EMI susceptibility/Electrostatic discharge Meets e mark for open equipment.
Open equipment should be installed in an industry standard enclosure, with access
restricted to qualied service personnel
Di-electric strength RS 232 is non-isolated from logic common
Indicator lights Run and communication actived
Power source Power supply on-board the Modicon Momentum I/O Base
Clock speed MHz 20 32 20 32
Scan time ms/K 1 0.63 1 0.63
Communication ports 1 Dedicated RS 232C Modbus
2 N/A Dedicated RS 485
Modbus
I/O Bus (derivative
of INTERBUS
Capacity 984 LL program memory K2.4 12
IEC program memory K 160
Data memory K2 4
Discrete I/O 2048 In/2048 Out (A total of 2048 words can be congured for
discrete analog I/O, any mix up to the stated limits.)
2048 In/2048 Out
Register I/O 2048 In/2048 Out (A total of 2048 words can be congured for
discrete and analog I/O, any mix up to the stated limits.)
4096 words total
I/O limit - I/O local on
Modbus
- I/O can be
extented using a
Modbus Plus option
adapter and Peer
Cop (2048 In/Out)
8192 bits max. :
- 4096 In/4096 Out
on I/O Bus
- I/O can be
extented using a
Modbus Plus option
adapter and Peer
Cop (2048 In/Out)
I/O bus addressing 80 I/O drops with
ProWORX
128 I/O drops with
Concept
References:
page 68
Specications
1
2
3
4
5
6
7
8
9
10
65
Modicon Momentum
automation platform
M1/M1E processor adapters
Environment
Type of processor 171 CCC 760 10 171 CCC 780 10
Temperature Operating °C 0...60
Storage °C - 40...85
Relative humidity 5...96% (non-condensing)
Altitude m 2000 (6,500 ft.)
Mechanical withstand
(immunity)
To vibrations 57...150 Hz @ 1 gn
10...57 Hz @ 0.075 mm d.a
To shocks
±
15 gn peak, 11 ms, half sine wave
Designed to meet UL, e, CUL, FM Class 1 Div. 2, NEMA 250 Type 1, and IP 20 conforming to IEC 529
Specications
Central processing unit (CPU) x 86 based
Word length bit 16
Material Lexan
Voltage Vdc 5.0 V (supplied by I/O Base)
Voltage tolerance
±
5% (as supplied by I/O Base)
RFI immunity/EMI susceptibility/Electrostatic discharge Meets e mark for open equipment.
Open equipment should be installed in an industry standard enclosure, with access
restricted to qualied service personnel
Di-electric strength RS 232 is non-isolated from logic common
Indicator lights Run and communication actived
Power source Power supply on-board the Modicon Momentum I/O Base
Clock speed MHz 32
Scan time ms/K 1
Communication ports 1 Dedicated RS 232C Modbus
2 I/O Bus (derivative of INTERBUS) Dedicated RS 485 Modbus
Capacity 984 LL program memory K18
IEC program memory K240
Data memory K24
Discrete I/O 8192 In/8192 Out (A total of 8192 bits can be congured for discrete and analog I/O,
any mix up to the stated limits)
Register I/O 26048 In/26048 Out (A total of 26048 words can be congured for discrete and analog
I/O, any mix up to the stated limits)
I/O limit 8192 bits max. :
- 4096 In/4096 Out on I/O Bus
- I/O can be extented using a
Modbus Plus option adapter and
Peer Cop (2048 In/Out)
- I/O local on Modbus
- I/O can be extented using a Modbus Plus
option adapter and Peer Cop
(2048 In/Out)
I/O bus addressing 80 I/O drops with ProWORX ,
128 I/O drops with Concept
References:
page 68
Specications (continued)
1
2
3
4
5
6
7
8
9
10
66
Modicon Momentum
automation platform
M1/M1E processor adapters
Environment
Type of processor 171 CCC 960 20 171 CCC 980 20
Temperature Operating °C 0...60
Storage °C - 40...85
Relative humidity 5...96% (non-condensing)
Altitude m 2000 (6,500 ft.)
Mechanical withstand
(immunity)
To vibrations 57...150 Hz @ 1 gn
10...57 Hz @ 0.075 mm d.a
To shocks
±
15 gn peak, 11 ms, half sine wave
Designed to meet UL, e, CUL, FM Class 1 Div. 2, NEMA 250 Type 1, and IP 20 conforming to IEC 529
Specications
Central processing unit (CPU) x 86 based
Word length bit 16
Material Lexan
Voltage Vdc 5.0 V (supplied by I/O Base)
Voltage tolerance
±
5% (as supplied by I/O Base)
RFI immunity/EMI susceptibility/Electrostatic discharge Meets e mark for open equipment.
Open equipment should be installed in an industry standard enclosure, with access
restricted to qualied service personnel
Di-electric strength Comm port is non-isolated from logic common
Indicator lights Processor adapter operating (RUN), Ethernet network status (LAN Act) and Ethernet
network activity (LAN STS)
Power source Power supply on-board the Modicon Momentum I/O Base
Flash memory K 512
Clock speed MHz 50
Scan time ms/K 3
Communication ports 1 Ethernet
2 I/O Bus (derivative of In t e r Bus) Dedicated RS 485 Modbus
Capacity 984 LL program memory K18
IEC program memory K
Data memory K24
Discrete I/O 8192 In/8192 Out (A total of 8192 bits can be congured for discrete and analog I/O,
any mix up to the stated limits)
Register I/O 26048 In/26048 Out (A total of 26048 words can be congured for discrete and analog
I/O, any mix up to the stated limits)
I/O limit 8192 bits max. :
- 4096 In/4096 Out on I/O Bus
- I/O can be extented using a
Modbus Plus option adapter and
Peer Cop (2048 In/Out)
- I/O local on Modbus
- I/O can be extented using a Modbus Plus
option adapter and Peer Cop
(2048 In/Out)
Transparent Ready services Class B10
Web services “Rack Viewer” access to the product description and status, and to the island
diagnostics
“Data editor” access to the conguration functions and variables
“Web page loader” software tool for loading user Web pages
Ethernet TCP/IP communication
management services
Modbus Messaging (read/write data words)
I/O Scanning
I/O bus addressing 80 I/O drops with ProWORX,
128 I/O drops with Concept
References:
page 68
Specications (continued)
1
2
3
4
5
6
7
8
9
10
67
Modicon Momentum
automation platform
M1/M1E processor adapters
Environment
Type of processor 171 CCC 960 30 171 CCC 980 30
Temperature Operating °C 0...60
Storage °C - 40...85
Relative humidity 5...96% (non-condensing)
Altitude m 2000 (6,500 ft.)
Mechanical withstand
(immunity)
To vibrations 57...150 Hz @ 1 gn
10...57 Hz @ 0.075 mm d.a
To shocks
±
15 gn peak, 11 ms, half sine wave
Designed to meet UL, e, CUL, FM Class 1 Div. 2, NEMA 250 Type 1, and IP 20 conforming to IEC 529
Specications
Central processing unit (CPU) x 86 based IEC Executive
Word length bit 16
Material Lexan
Voltage Vdc 5.0 V (supplied by I/O Base)
Voltage tolerance
±
5% (as supplied by I/O Base)
RFI immunity/EMI susceptibility/Electrostatic discharge Meets e mark for open equipment.
Open equipment should be installed in an industry standard enclosure, with access
restricted to qualied service personnel
Di-electric strength Comm port is non-isolated from logic common
Indicator lights Processor adapter operating (RUN), Ethernet network status (LAN Act) and Ethernet
network activity (LAN STS)
Power source Power supply on-board the Modicon Momentum I/O Base
Flash memory Mb 1
Clock speed MHz 50
Scan time ms/K 3
Communication ports 1 Ethernet
2 I/O Bus (derivative of In t e r Bus) Dedicated RS 485 Modbus
Capacity 984 LL program memory K18
IEC program memory K200
Data memory K24
Discrete I/O 8192 In/8192 Out (A total of 8192 bits can be congured for discrete and analog I/O,
any mix up to the stated limits)
Register I/O 26048 In/26048 Out (A total of 26048 words can be congured for discrete and analog
I/O, any mix up to the stated limits)
I/O limit 8192 bits max. :
- 4096 In/4096 Out on I/O Bus
- I/O can be extented using a
Modbus Plus option adapter and
Peer Cop (2048 In/Out)
- I/O local on Modbus
- I/O can be extented using a Modbus Plus
option adapter and Peer Cop
(2048 In/Out)
Transparent Ready services Class B10
Web services “Rack Viewer” access to the product description and status, and to the island
diagnostics
“Data editor” access to the conguration functions and variables
“Web page loader” software tool for loading user Web pages
Ethernet TCP/IP communication
management services
Modbus Messaging (read/write data words)
I/O Scanning
I/O bus addressing 80 I/O drops with ProWORX,
128 I/O drops with Concept
References:
page 68
Specications (continued)
1
2
3
4
5
6
7
8
9
10
68
Modicon Momentum
automation platform
M1/M1E processor adapters
M1/M1E processor adapters
RAM Memory Comm Port(s) Clock Speed Reference Weight
kg (oz)
64 K
1 Modbus20 MHz 171 CCS 700 00 0.042 (1.5)
1 Modbus 32 MHz 171 CCS 700 10 0.042 (1.5)
2 Modbus 20 MHz 171 CCS 780 00 0.042 (1.5)
256 K 1 Modbus,
1 I/O Bus
32 MHz 171 CCS 760 00 0.042 (1.5)
512 K
1 Modbus,
1 I/O Bus
32 MHz 171 CCC 760 10 0.042 (1.5)
2 Modbus 32 MHz 171 CCC 780 10 0.042 (1.5)
544 K
(1)
1 Modbus,
1 Ethernet
50 MHz 171 CCC 980 20 0.042 (1.5)
1 Ethernet,
1 I/O Bus
50 MHz 171 CCC 960 20 0.042 (1.5)
544 K, IEC Exec
(1)
1 Modbus,
1 Ethernet
50 MHz 171 CCC 980 30 0.042 (1.5)
1 Ethernet,
1 I/O Bus
50 MHz 171 CCC 960 30 0.042 (1.5)
(1) Transparent Ready Class B10 (embedded standard Web server - standard Ethernet TCP/IP
communication services). For more details, consult our catalog “Transparent Ready,
Ethernet TCP/IP and Web technologies”.
171 CCS 7p0 p0
171 CCC 7p0 10
171 CCC 9p0 20/30
Specications:
page 64
References
1
2
3
4
5
6
7
8
9
10
69
Modicon Momentum
automation platform
M1/M1E processor adapters
References (continued)
Connection accessories and documentation
Description Type Sold in lot of Reference Weight
kg (oz)
RS 232
communication
cable RJ45 to RJ45
1 m (3 ft) 110 XCA 282 01
3 m (10 ft) 110 XCA 282 02
6 m (20 ft) 110 XCA 282 03
RS 485 cable
connector T for
RJ45
––170 XTS 040 00
RS 485 terminating
(RJ45 resistor plugs)
–2170 XTS 021 00
D-shell adapters RJ45 to 9-pin
(for AT serial port)
110 XCA 203 00
RJ45 to 25-pin
(for XT serial port)
110 XCA 204 00
Ground clamp ––424 244 739
ConneXium
cabling system
Ethernet cabling for
M1E processor
adapters
See page 76
Concept software See page 95
ProWORX
software
See page 99
Processor adapters
user guide
See page 103
1
2
3
4
5
6
7
8
9
10
70
Modicon Momentum
automation platform
Option adapters
Conguration Modbus Plus option adapters
Communication network Modbus Plus
Communication port(s) 1 Modbus Plus 2 redundant Modbus Plus
Comm port connector 9-pin D-shell
Time-of-day clock On-board, ± 13 sec/day accuracy
Back-up battery User-replaceable 2/3 AA Lithium
Voltage 5 Vdc supplied by I/O base
Operating temperature 0 ... 60°C
Humidity 5 ... 95%, relative noncondensing
Shock ± 15 g peak, 11 ms, half-sine wave
Vibration 10 ... 57 Hz @ 0,075 mm d.a.
Type of module 172 PNN 210 22 172 PNN 260 22
Page 75
Serial option adapter
General-purpose serial communications
1 software-selectable RS 232/RS 485 serial port
9-pin D-shell
On-board, ± 13 sec/day accuracy
User-replaceable 2/3 AA Lithium
5 Vdc supplied by I/O base
0 ... 60°C
5 ... 95%, relative noncondensing
± 15 g peak, 11 ms, half-sine wave
10 ... 57 Hz @ 0,075 mm d.a.
172 JNN 210 32
75
Selection guide
1
2
3
4
5
6
7
8
9
10
71
Serial option adapter
General-purpose serial communications
1 software-selectable RS 232/RS 485 serial port
9-pin D-shell
On-board, ± 13 sec/day accuracy
User-replaceable 2/3 AA Lithium
5 Vdc supplied by I/O base
0 ... 60°C
5 ... 95%, relative noncondensing
± 15 g peak, 11 ms, half-sine wave
10 ... 57 Hz @ 0,075 mm d.a.
172 JNN 210 32
75
1
2
3
4
5
6
7
8
9
10
72
Modicon Momentum
automation platform
Option adapters
Introduction
Modicon Momentum option adapters, mounted on Modicon Momentum I/O
bases, can be used to enhance the capabilities of the Modicon Momentum
processor adapters that mount on top of the option adapter. These option adapters
allow you to network your local logic solvers together into an intelligent subsystem as
part of a larger Schneider Electric application, or into a stand alone, integrally
networked system with local controllers with extended I/O.
Modicon Momentum option adapter models include:
172 PNN 210 22 - one Modbus Plus communication port
172 PNN 260 22 - two redundant Modbus Plus communication ports
172 JNN 210 32 - one general-purpose serial communication port, RS 232 or
RS 485 selectable
Each of these option adapters provides an on-board, TOD (Time-Of-Day) clock that
is available to the application residing in the processor adapter. The clock is useful
for the scheduling of events, time-stamping operations and operator interface
requirements. In addition, each option adapter contains a battery-backup system that
maintains the application and its variables in the event of a power outage to the
processor adapter. The option adapter’s convenient side-door access allows for
quick replacement of the single 2/3 AA Lithium battery.
In addition to the TOD clock and battery backup features, the 172 PNN 210 22
adapter allows you to add networking to the intelligent I/O base. Model 172 PNN 260 22
allows you to add redundantly-cabled networking to the I/O base. This opens the
Modicon Momentum product line to a broad spectrum of applications. You can use
the port to connect to other processors, such as:
b Other Modicon Momentum processor/option adapters
b Other PLCs enabled with Modbus Plus
b Modicon Momentum Modbus Plus communication adapters and I/O bases
b Other third party devices using Modbus Plus to communicate
Model 172 JNN 210 32 allows you to add a second, defacto-industry standard
Modbus port (selectable RS 232/485) to the I/O base. You can use the port to
connect to other processors, such as other Modicon Momentum processor/option
adapters, and to other devices, such as operator interface panels and display
marquees.
Programming software for Modicon Momentum
Modicon Momentum processor adapters have a number of PC programming
software options available. You can program your processor adapter via the
Modbus RS 232 serial port, or if using a Modbus Plus option adapter in conjunction
with a processor adapter, via an SA85 card installed in a PC and connected to the
same Modbus Plus network. For more specic information, see the appropriate
Modicon Momentum, ProWORX, and Concept programming software
documentation.
Introduction
1
2
3
4
5
6
7
8
9
10
73
Modicon Momentum
automation platform
Option adapters
Description
A typical Modicon Momentum option adapter consists of the following components :
1 9-pin D-shell connector(s) for Modbus Plus communications
2 Batttery compartment
3 LED indicators
4 Address switches for Modbus Plus
Mounting
Modicon Momentum option adapters provide the processor adapters with additional
networking capabilities, a time-of-day clock, and a battery back-up. The option
adapters also snap onto the I/O base; in this gure, the processor adapter stacks on
top. Here, the option adapter is used in conjunction with the processor adapter to
extend the system’s I/O capacity.
1
2
3
4
Description
1
2
3
4
5
6
7
8
9
10
74
Modicon Momentum
automation platform
Option adapters
Specications
Model No 172 PNN 210 22 172 PNN 260 22 172 JNN 210 32
Time-of-day clock On-board, ± 13 s/day accuracy
Battery Type User-replaceable 2/3 AA Lithium
Service life < 30 days from the time a battery-low indication is received, to actual battery failure
@ 40 °C maximum service life ambient temperature with the system continuously
powered down
Shelf life In excess of 5 years at room temperature
Communication port(s) One Modbus Plus port
Drop address range 1...64
Two redundant Modbus
Plus ports
General-purpose serial port
RS 232 or RS 485
selectable
Comm port connector(s) 9-pin D-shell
Operating temperature °C 0...60
Storage temperature °C - 40...85
Relative humidity 5...95% (non-condensing)
Altitude m (ft) 2000 (6,562)
Shock ± 15 gn peak, 11ms, half sine wave
Vibration Hz 57...150 @ 1 gn
10...57 @ 0.075 mm d.a.
Height in
(mm)
1.01 (25.)
[2.10 (58.3) on battery side]
Width in
(mm)
5.57 (143.1)
Depth in
(mm)
2.36 (60.06)
Weight oz
(g)
3.00 (85.05)
Material Lexan
Voltage Vdc 5.0 (supplied by I/O base)
Voltage tolerance ± 5% (as supplied by I/O base)
RFI immunity/EMI susceptibility/Electrostatic discharge Meets e mark for open equipment. Open equipment should be installed in an industry
standard enclosure, with access resricted to qualied service personnel
Di-electric strength Vdc 500
Designed to meet UL, e, CSA, NEMA 250 Type 1, and IP 20 conforming to
IEC 529
UL, CSA, NEMA 250 Type 1,
and IP 20 conforming to
IEC 529, FM Class I, Div. II
Packaging Standard Modicon Momentum option adaptator
Indicator lights Communication active light
Power source Power supply on-board the Modicon Momentum I/O base
Specications
1
2
3
4
5
6
7
8
9
10
75
Modicon Momentum
automation platform
Option adapters
Option adapter modules
Description Reference Weight
kg (oz)
Modbus Plus option adapter, single Port 172 PNN 210 22 0.070 (2.5)
Modbus Plus option adapter, dual redundant ports 172 PNN 260 22 0.070 (2.5)
Serial option adapter, single serial port 172 JNN 210 32 0.070 (2.5)
Accessories
Description Use Length Reference Weight
kg
From To
Standard Modbus Plus cables T-junction box T-junction box 30 m (100 ft) 490 NAA 271 01
150 m (500 ft) 490 NAA 271 02
300 m (1000 ft) 490 NAA 271 03
450 m (1500 ft) 490 NAA 271 04
1500 m (5000 ft) 490 NAA 271 06
Modbus Plus Drop cables Communication
modules for Modicon
Momentum I/O bases
T-junction box 2.4 m (8 ft) 900 NAD 211 10 0.530
6 m (20 ft) 990 NAD 211 30 0.530
Modbus Plus RS 485 cables 25 m (10.0 in) 170 MCI 020 10
1 m (3 ft) 170 MCI 020 36
RS 485 master communication
cable (RJ45/RJ45)
0.3 m (1 ft) 170 MCI 041 10
Modbus Plus RJ45 cable 3 m (10 ft) 170 MCI 021 20
Modbus Plus RJ45 cables
double-ended
3 m (10 ft) 170 MCI 021 80
10 m (30 ft) 170 MCI 020 80
RS 232 communication cables
(RJ45/RJ45)
1 m (3 ft) 110 XCA 282 01
3 m (10 ft) 110 XCA 282 02
6 m (20 ft) 110 XCA 282 03
Description Use Reference Weight
kg
Modbus Plus taps IP 20 junction box for tap-off connection (T), integrate the
terminator. Requires the wiring tools 043 509 383
990 NAD 230 00 0.230
IP 65 junction box for tap-off connection (T), supports 1 RJ45
connector on front panel for terminal
990 NAD 230 10
Modbus Plus line connector
(9-Pin Sub-D)
Communication module connection AS MBKT 085
Modbus Plus line terminators
(sold in lot of 2)
2 impedance adapters for box
(IP 20) 990 NAD 230 00 (replacement part)
AS MBKT 185
2 impedance adapters for box
(IP 65) 990 NAD 230 10
990 NAD 230 11
D-shell adapters RJ45 to 9-pin (for AT serial port) 110 XCA 203 00
RJ45 to 25-pin (for XT serial port) 110 XCA 204 00
Description Sold in lots of Reference Weight
kg (oz)
RS 485 (9-Pin Sub-D) cable connector T for RJ45 170 XTS 040 00
RJ45 shielded connectors 25 170 XTS 022 00
Modbus Plus terminating RJ45 resistor plugs 2170 XTS 021 00
RS 485 (RJ45) cable connector T for RJ45 170 XTS 041 00
RS 485 Multi-Master RJ45 shunt plugs 2170 XTS 042 00
Modbus Plus (9-Pin Sub-D) cable connector T for RJ45 170 XTS 020 00
Ground clamp 424 244 739
Wiring tool
Mounting trunk and tap wires on the IP20 junction box 990 NAD 230 00
043 509 383
172 PNN 210 22
172 PNN 260 22
172 JNN 210 32
References
1
2
3
4
5
6
7
8
9
10
76
Ethernet network
Cabling system
Infrastructure
Introduction
Schneider Electric offers copper and ber optic Ethernet cables for wiring your IP 20
and IP 67 devices.
Examples
Combined IP 20 and IP 67 wiring (copper)
For key:
1, 3: Straight copper cordsets
2, 4: Crossed copper cordsets
8: Cables with IP 67 connector
see pages 78 and 79.
2, 4
2, 4
2, 4
1, 3
1, 3
1, 3
1, 3
1, 3
8
8
1, 3
Wiring system
1
2
3
4
5
6
7
8
9
10
77
Ethernet network
Cabling system
Infrastructure
Examples (continued)
Combined Copper and Fiber wiring
For key:
1, 3: Straight cables
2, 4: Crossed cord cables
5, 6, 7: Fiber optic cables
8: Cables with IP 67 connector
see pages 78 and 79.
Firewall
5, 6, 7
2, 4
8
Magelis XBT
Magelis XBT
Modicon STB
Modicon STBTwido
Altivar 71
drive
Altivar 71
drive
OsiTrack
Modbus
Modicon M340
Modicon Quantum
Modicon Premium
1, 3 1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 3
1, 31, 3
1, 3
1, 3
1, 3
1, 3
2, 4
2, 4
2, 4 2, 4
2, 4 2, 4
2, 4 2, 4
2, 4
Preventa safety PLC
Internet
MES Client
Router
FactoryCast
gateway
Managed switch
Hub or
unmanaged switch
Fiber link
Copper link
Copper link
Wiring system (continued)
Server
1
2
3
4
5
6
7
8
9
10
78
Ethernet network
Cabling system
ConneXium connection components
Shielded copper connection cables
ConneXium shielded connection cables are available in two versions to meet current standards
and approvals:
b EIA/TIA 568 shielded twisted pair cables for e market
These cables conform to:
- EIA/TIA-568 standard, category CAT 5E
- IEC 11801/EN 50173 standard, class D
Their re resistance conforms to:
- NF C32-070# C2 classication
- IEC 322/1 standards
- Low Smoke Zero Halogen (LSZH)
b EIA/TIA 568 shielded twisted pair cables for UL market
The cable material is:
- CEC type FT-
- NEC type CM
EIA/TIA 568 shielded twisted pair cables for e market
Description Preformed at both ends Rep. Length
m (ft)
Reference Weight
kg
Straight cables 2 RJ45 connectors
For connection to terminal
devices (DTE)
12 (6.6) 490 NTW 000 02
5 (16.4) 490 NTW 000 05
12 (39.4) 490 NTW 000 12
40 (131.2) 490 NTW 000 40
80 (262.5) 490 NTW 000 80
Crossed cord
cables
2 RJ45 connectors
For wiring diagrams
between hubs, switches
and transceivers
25 (16.4) 490 NTC 000 05
15 (49.2) 490 NTC 000 15
40 (131.2) 490 NTC 000 40
80 (262.5) 490 NTC 000 80
EIA/TIA 568 shielded twisted pair cables for UL market
Description Preformed at both ends Rep. Length
m (ft)
Reference Weight
kg
Straight cables 2 RJ45 connectors
For connection to terminal
devices (DTE)
32 (6.6) 490 NTW 000 02U
5 (16.4) 490 NTW 000 05U
12 (39.4) 490 NTW 000 12U
40 (131.2) 490 NTW 000 40U
80 (262.5) 490 NTW 000 80U
Crossed cord
cables
2 RJ45 connectors
For wiring diagrams
between hubs, switches
and transceivers
45 (16.4) 490 NTC 000 05U
40 (131.2) 490 NTC 000 40U
80 (262.5) 490 NTC 000 80U
“Do it Yourself” cable and connectors
The “Do It Yourself” offer is comprised of 2 references for “eld installable” connectors (M12 and
RJ45) and one reference for spooled cable measuring 300 m. The product are intented for use in
industrial Ethernet networks supporting transmission rates up to 100 Mbit/s over the combined
maximum cable lenght up to 80 m.
Quick, on-the-oor assembly is accomplished with only a knife and pliers.
Description According to Length
m (ft)
Reference Weight
kg
Ethernet copper
cable
2 shielded
twisted pairs
24 AWG
EIA/TIA-568 (80 m max. link
length)
UL 508-CM, e
EN 50173 Class D
300 m
(1000)
TCS ECN 300R2
RJ45 connector
IP 20
EIA/TIA-568-D,
category CAT 5E, eTCS EK3 MDS
M12 connector
D-Code,
IP 65/67
IEC 60176-2-101,
EN 50173 Class D
TCS EK1 MDRS
(1) For key to numbers, see pages76 and 77.
490 NTp 000 pp
Wiring system (continued)
1
2
3
4
5
6
7
8
9
10
79
Ethernet network
Cabling system
ConneXium connection components
Glass ber optic cables
These glass ber optic cables are for wiring:
b To a terminal device (DTE)
b Between hubs, transceivers and switches
Description Preformed at both
ends
Rep. Length
m (ft)
Reference Weight
kg
Glass ber optic
cables
1 SC connector
1 MT-RJ connector
55 (16.4) 490 NOC 000 05
1 ST connector (BFOC)
1 MT-RJ connector
65 (16.4) 490 NOT 000 05
2 MT-RJ connectors 73 (9.8) 490 NOR 000 03
5 (16.4) 490 NOR 000 05
Separate parts for TCS ESM switches
Description Optical ber Type Reference Weight
kg
Fiber optic
modules for
Gigabit ports with
LC connector
(1)
Multi-mode 50/125 µm
or 62.5/125µm
1000BASE-SX TCS EAA F1LFU00 0.040
Single mode 9/125 µm 1000BASE-LH TCS EAA F1LFH00 0.040
Multi-mode 50/125 µm
or 62.5/125 µm
Single mode 62.5/125 µm
1000BASE-LX TCS EAA F1LFS00 0.040
Conguration
backup key
Via the USB port on the front of the
switch, used to:
save and retrieve the switch -
conguration
update the internal software -
TCS EAM 0100
(1) Dimensions W x H X D = 20 x 18 x 50 mm.
Connection components for IP 67 switch
Description Preformed at both
ends
Rep. Length
m (ft)
Reference Weight
kg
Copper cables 1 IP 67 4-way M12
connector
and 1 RJ45 connector
81 (3.3) TCS ECL 1M3M 1S2
3 (9,8) TCS ECL 1M3M 3S2
10 (32.8) TCS ECL 1M3M 10S2
25 (82) TCS ECL 1M3M 25S2
40 (131.2) TCS ECL 1M3M 40S2
2 IP 67 4-way M12
connectors
1 (3.3) TCS ECL 1M1M 1S2
3 (9,8) TCS ECL 1M1M 3S2
10 (32.8) TCS ECL 1M1M 10S2
25 (82) TCS ECL 1M1M 25S2
40 (131.2) TCS ECL 1M1M 40S2
Power cables Female M12 straight
connector
2 (6.6) XZC P1164L2
5 (16.4) XZC P1164L5
Female M12 elbowed
connector
2.5 (8.2) XZC P1264L2
5 (16.4) XZC P1264L5
Power
connectors
Female M12 straight
connector
XZC C12 FDM 50B
Female M12 elbowed
connector
XZC C12 FCM 50B
M12/RJ45
adaptor
IP 67 female 4-way M12
connector and female
RJ45 connector
TCS EAA F11F13F00
TCS EAA F1LFp 00
490 NOC 000 05
MT-RJ
SC
490 NOT 000 05
MT-RJ
ST
490 NOR 000 05
MT-RJ
MT-RJ
Wiring system (continued)
1
2
3
4
5
6
7
8
9
10
80
Ethernet network
Cabling system
ConneXium hub
Introduction
Hubs (concentrators) are used for transmitting signals between several media ports.
Hubs are “plug and play” devices that do not need any conguration.
The use of hubs makes it possible to create the following topologies:
b Star topology using hubs
b Tree topology using hubs
Specications and reference
Hubs
Interfaces Copper cable ports Number and type 4 x 10BASE-T ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fiber optic ports Number and type
Topology Number of cascaded hubs max. 4
Number of hubs in a ring
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V (18…32) c, safety extra low voltage (SELV)
Power consumption 80 mA (130 max. at 24 V c)
Removable connector 5-way
Operating temperature 0…+ 60 °C
Relative humidity 10…95% non condensing
Degree of protection IP 30
Dimensions W x H x D 40 x 125 x 80 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.530 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 Class 1 Division 2,
e, GL, C-Tick
FM 3810, FM 3611 Class 1 Division 2
LED indicators Power supply, activity, link
Alarm relay Detected power supply fault, detected Ethernet network fault, or detected communication port
fault (1 A max. volt-free contact at 24 V c)
Reference 499 NEH 104 10
DTE DTE
DTE DTE
DTE DTE
Star topology Tree topology
Hub
Hub
HubHub
Product data sheet
1
2
3
4
5
6
7
8
9
10
81
Ethernet network
Cabling system
ConneXium transceiver
Introduction
The use of ConneXium transceivers makes it possible to perform the following:
b Creation of linear ber optic bus topologies, for products with twisted pair cable
Ethernet connection
b Interfacing products with twisted pair cable Ethernet connection with a ber
optic cable
Transceivers are “plug and play” devices that do not need any conguration.
ConneXium transceivers provide ber optic wiring for transmission in areas
subject to interference (high levels of electromagnetic interference) and for long
distance communications.
Specications and reference
Transceivers
Interfaces Copper cable ports Number and type 1 x 100BASE-TX port
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair 100 m
Fiber optic ports Number and type 1 x 100BASE-FX port
Connectors SC
Medium Multi-mode optical ber
Length of optical ber
50/125 µm ber 3000 m (1)
62.2/125 µm ber 3000 m (1)
Attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V (18…32) c, safety extra low voltage (SELV)
Power consumption 160 mA (190 max. at 24 V c)
Removable connector 5-way
Operating temperature 0…+ 60 °C
Relative humidity 10…95% non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.230 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 Class 1 Division 2,
e, GL, C-Tick
LED indicators P1 and P2 power supplies, Ethernet link/port status
Alarm relay Detected power supply fault, detected Ethernet network fault, or detected communication port
fault (1 A max. volt-free contact at 24 V c)
Reference 499 NTR 101 00
(1) Length dependent on the attenuation analysis and attenuation of the optical ber (typical
value: 2000 m).
DTEDTE
DTE
Linear topology on optical ber
Product data sheet
1
2
3
4
5
6
7
8
9
10
82
Ethernet network
Cabling system
ConneXium unmanaged switches
Introduction
Switches are used to increase the limits of
architectures based on hubs or transceivers
by separating collision domains.
Higher layer communication is provided between the
ports, and collisions at link layer are not propagated
(ltering). Switches improve performance by better
allocation of the pass band due to the reduction of
collisions and the network load.
Certain Connexium switch models also enable
redundant architectures to be created on twisted pair
copper ring or ber optic.
Switches are “plug & play” devices that do not need any
conguration. They can also be managed remotely via
the SNMP or HTTP protocols for monitoring and
diagnostics purposes.
Specications and references: twisted pair
Switches Copper twisted pair, unmanaged
Interfaces Copper
cable ports
Number and type 5 x 10BASE-T/ 100BASE-TX ports 8 10BASE-T/100BASE-TX ports
Shielded connectors M12 (type D) RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Ethernet services Storage and re-routing of received data, auto
MDI/MDX, automatic negotiation of
10/100 Mbit/s and duplex mode, automatic
change of polarity
Topology Number of switches Cascaded Unlimited
Redundant in a ring
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32) safety extra low voltage (SELV)
Power consumption mA max. 100 125 (290 max.)
Removable connector 5-way M12 (type A, male) 5-way
Operating temperature 0…+ 60 °C
Relative humidity 10…95% non condensing
Degree of protection IP 67 IP 20
Dimensions W x H x D
60 x 126 x 31 mm
47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.210 kg 0.230 kg
Conformity to standards cUL 508 and CSA 22.2 No. 142 cUL 60950, UL 508 and CSA 22.2 No. 142, UL
1604 and CSA 22.2 No. 213 Class 1 Division 2,
e, GL, C-Tick
LED indicators Power supply, link status, line activity P1 and P2 power supplies, Ethernet link/port
status
Alarm relay Detected power supply fault, detected
Ethernet network fault, or detected
communication port fault (1 A max. volt-free
contact at 24 V c)
Reference TCS ESU 051F0 499 NES 181 00
IP 67 cordsets
Ethernet cordsets Preformed at each end, see page 79
Power supply cables Preformed at each end with M12 female
straight connectors
Preformed at each end with female M12
angled connectors
Length 2 m Length 5 m Length 2 m Length 5 m
Reference XZC P1164L2 XZC P1164L5 XZC P1264L2 XZC P1264L5
Spare power connectors Female M12 straight connector Female M12 angled connector
Reference XZC C12 FDM 50B XZC C12 FCM 50B
Product data sheet
DTE
DTEDTE
DTE DTE
DTE DTE
DTE DTE
DTE
DTEDTE
DTE DTE
DTE
DTEDTE
DTE DTE
DTE DTE
100 Mbps optical
ring
Collision domain
1
Collision domain
2
Collision
domain 3
1
2
3
4
5
6
7
8
9
10
83
Specications and references: 3, 4 and 5 ports, twisted pair, ber optic
Switches Copper twisted pair, unmanaged
Interfaces Copper cable ports Number and type 3 x 10BASE-T/ 100BASE-TX
ports
4 x 10BASE-T/ 100BASE-TX
ports
5 x 10BASE-T/ 100BASE-TX
ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Fiber optic ports Number and type 1 x 100BASE-FX ports
Connectors Duplex SC
Medium Multi-mode optical ber
Length of optical ber
50/125 µm ber
5000 m (1)
62,2/125 ber
4000 m (1)
Attenuation analys
50/125 µm ber
8 dB
62,2/125 µm ber
11 dB
Ethernet services Storage and re-routing of received data, auto MDI/MDX (automatic switching depending on
whether cables are straight or crossed), automatic negotiation of 10/100 Mbit/s and duplex mode,
automatic change of polarity
Topology Number of switches Cascaded Unlimited
Redundant in a ring
Redundancy
Power supply Voltage, safety extra low voltage (SELV) c 24 V (c 9,6…32 V)
Power consumption Max. 2,2 W Max. 3,9 W Max. 2,2 W
Connector 3 way removable connector
Operationg température 0…+ 60°C
Relative humidity Max. 95 % non condensing
Degree of protection IP 30
Dimensionss W x H x D 25 x 114 x 79 mm
Weight 0,113 kg 0,120 kg 0,113 kg
Conformity to standards UL 508 and CSA 22.2 No.142
IEC/EN 61131-2, IEC 60825-1 class 1, CISPR 11A
LED indicators Power supply, copper port activity, 10 or 100 Mbit/s data rate
Fiber port state and activity
Alarm relay
Référence TCS ESU 033FN0 TCS ESU 043F1N0 TCS ESU 053FN0
(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 2,000 m).
Ethernet network
Cabling system
ConneXium unmanaged switches
Product data sheet
(continued)
1
2
3
4
5
6
7
8
9
10
84
Ethernet network
Cabling system
ConneXium unmanaged switches
Specications and references: 5 ports, twisted pair and ber optic
Switches Copper twisted pair and ber optic, unmanaged
Interfaces Copper
cable ports
Number and type 4 x 10BASE-T/
100BASE-TX ports
3 x 10BASE-T/
100BASE-TX ports
4 x 10BASE-T/
100BASE-TX ports
3 x 10BASE-T/
100BASE-TX ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Connectors SC
Medium Multi-mode optical ber Single mode optical ber
Length of optical ber
50/125 µm ber 5,000 m (1)
62.2/125 µm ber 4,000 m (1)
9/125 µm ber 32,500 m (2)
Attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
9/125 µm ber 16 dB
Topology Number of switches Cascaded Unlimited
Redundant in a ring
Redundancy P1 and P2 redundant power supplies
Power supply Voltage 24 V c (18…32), safety extra low voltage (SELV)
Power consumption mA max. 200 240 200 240
Removable connector 5-way
Operating temperature -40...+70 °C
Relative humidity 10…95% non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 135 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.330 kg 0.335 kg 0.330 kg 0.335 kg
Conformity to standards cUL 60950, cUL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 Class 1 Division 2,
e, GL, C-Tick
LED indicators P1 and P2 power supplies, Ethernet link status, transmission activity
Alarm relay Activity, detected power supply fault, detected Ethernet network fault, or detected
communication port fault (1 A max. volt-free contact at 24 V c)
Reference 499 NMS 251 01 499 NMS 251 02 499 NSS 251 01 499 NSS 251 02
(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 2,000 m).
(2) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 15,000 m).
Product data sheet
(continued)
1
2
3
4
5
6
7
8
9
10
85
Ethernet network
Cabling system
ConneXium managed switches
Specications and references: 4 ports, twisted pair and ber optic
Switches Copper twisted pair and ber optic, managed
Interfaces Copper cable ports Number and type 3 x 10/100BASE-TX
ports
2 x 10/100BASE-TX
ports
3 x 10/100BASE-TX
ports
2 x 10/100BASE-TX
ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2 x 100BASE-FX ports
Connectors Duplex SC
Medium Multi-mode optical ber Single mode optical ber
Length of optical ber
50/125 µm ber 5,000 m (1)
62.2/125 µm ber 4,000 m (1)
9/125 µm ber 32,500 m (2)
Attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
9/125 µm ber 16 db
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream
control, secure port
Topology Number of switches Cascaded Unlimited
Redundant in a ring max. 50
Redundancy Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage Operation 9.6...60 V c/18…30 V a, safety extra low voltage (SELV)
Power consumption 6.5 W 7.3 W 6.5 W 7.3 W
Removable connector 6-way
Operating temperature 0…+ 60 °C
Relative humidity 10…90% non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.400 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 Class 1 Division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 Class 1 Division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management, copper
port status and copper port activity
Alarm relay Detected power supply fault, detected Ethernet network fault, detected communication port fault,
detected redundancy fault (1 A max. volt-free contact at 24 V c)
Reference TCS ESM 043F1CU0 TCS ESM 043F2CU0 TCS ESM 043F1CS0 TCS ESM 043F2CS0
(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 2,000 m).
(2) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 15,000 m).
Product data sheet
1
2
3
4
5
6
7
8
9
10
86
Ethernet network
Cabling system
ConneXium managed switches
Specications and references: 4 and 8 ports, twisted pair
Switches Copper twisted pair, managed
Interfaces Copper cable ports Number and type 4 x 10/100BASE-TX ports 8 x 10/100BASE-TX ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Fiber optic ports Number and type
Connectors
Medium
Length of optical ber
50/125 µm ber
62.2/125 µm ber
9/125 µm ber
Attenuation analysis
50/125 µm ber
62.2/125 µm ber
9/125 µm ber
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream
control, secure port
Topology Number of switches Cascaded Unlimited
Redundant in a ring max. 50
Redundancy Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage Operation 9.6...60 V c/18…30 V a, safety extra low voltage (SELV)
Power consumption 5.3 W 5.3 W
Removable connector 6-way
Operating temperature 0…+ 60 °C
Relative humidity 10…90% non condensing
Degree of protection IP 20
Dimensions W x H x D 47 x 131 x 111 mm 74 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.400 kg
0.410 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 Class 1 Division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 Class 1 Division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status, active
redundancy, redundancy management,
copper port status and copper port activity
Power supply status, alarm relay status, active
redundancy, redundancy management,
ber port status and ber port activity
Alarm relay Detected power supply fault, detected Ethernet network fault, or detected communication port
fault (1 A max. volt-free contact at 24 V c)
Reference TCS ESM 043F23F0 TCS ESM 083F23F0
Product data sheet
(continued)
1
2
3
4
5
6
7
8
9
10
87
Ethernet network
Cabling system
ConneXium managed switches
Specications and references: 8 ports, twisted pair and ber optic
Switches Copper twisted pair and ber optic, managed
Interfaces Copper cable ports Number and type 7 x
10/100BASE-TX ports
6 x
10/100BASE-TX ports
7 x
10/100BASE-TX ports
6 x
10/100BASE-T ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Fiber optic ports Number and type 1 x 100BASE-FX port 2 x 100BASE-FX ports 1 x 100BASE-FX port 2x 100BASE-FX ports
Connectors Duplex SC
Medium Multi-mode optical ber Single mode optical ber
Length of optical ber
50/125 µm ber 5,000 m (1)
62.2/125 µm ber 4,000 m (1)
9/125 µm ber 32,500 m (2)
Attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
9/125 µm ber 16 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream
control, secure port
Topology Number of switches Cascaded Unlimited
Redundant in a ring max. 50
Redundancy Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage Operation 9.6...60 V c/18…30 V a, safety extra low voltage (SELV)
Power consumption 6.5 W 7.3 W 6.5 W 7.3 W
Removable connector 6-way
Operating temperature 0…+ 60 °C
Relative humidity 10… 90% non condensing
Degree of protection IP 20
Dimensions W x H x D 74 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.410 kg
Conformity to standards IEC/EN 61131-2, IEC 61850-3, UL 508, UL 1604 Class 1 Division 2, CSA 22.2 No. 214 (cUL),
CSA 22.2 No. 213 Class 1 Division 2 (cUL), e, GL, C-Tick
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
ber port status and ber port activity
Alarm relay Detected power supply fault, detected Ethernet network fault, or detected communication port
fault (1 A max. volt-free contact at 24 V c)
Reference TCS ESM 083F1CU0 TCS ESM 083F2CU0 TCS ESM 083F1CS0 TCS ESM 083F2CS0
(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 2,000 m).
(2) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 15,000 m).
Product data sheet
(continued)
1
2
3
4
5
6
7
8
9
10
88
Ethernet network
Cabling system
ConneXium managed switches
Specications and references: 16 and 24 ports, twisted pair, ber optic
Switches Copper twisted pair,
managed
Copper twisted pair and ber optic, managed
Interfaces Copper cable ports Number and type 16 x 10/100BASE-TX ports 14 x 10/100BASE-TX ports 22 x 10/100BASE-TX ports
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Fiber optic ports Number and type 2 x 100BASE-FX ports
Connectors Duplex SC
Medium Multi-mode optical ber
Length of optical ber
50/125 µm ber 5,000 m (1)
62.2/125 µm ber 4,000 m (1)
9/125 µm ber
Attenuation analysis
50/125 µm ber 8 dB
62.2/125 µm ber 11 dB
9/125 µm ber
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream
control, secure port
Topology Number of switches Cascaded Unlimited
Redundant in a ring max. 50
Redundancy Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage Operation 9.6...60 V c/18…30 V a, safety extra low voltage (SELV)
Power consumption 9.4 W 11.8 W 15.5 W
Removable connector 6-way
Operating temperature 0…+ 60 °C
Relative humidity 10… 90% non condensing
Degree of protection IP 20
Dimensions W x H x D 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.600 kg 0.650 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No 142, UL 1604 and CSA 22.2 No 213 Class 1 Division 2,
e, GL, C-Tick
LED indicators Redundant power supplies,
single ring
Redundant power supplies, single ring, double ring
Alarm relay Detected power supply fault, detected Ethernet network fault, or detected communication port
fault (1 A max. volt-free contact at 24 V c)
Reference TCS ESM 163F23F0 TCS ESM 163F2CU0 TCS ESM 243F2CU0
(1) Length dependent on the attenuation analysis and attenuation of the ber optic (typical
value: 2,000 m).
Product data sheet
(continued)
1
2
3
4
5
6
7
8
9
10
89
Ethernet network
Cabling system
ConneXium managed switches
Specications and references: 8 ports and 2 Gigabit ports, twisted pair, ber optic
Switches Copper twisted pair and ber optic, managed Copper twisted pair, managed
Interfaces Copper cable ports Number and type 8 x 10/100BASE-TX ports 8 x 10/100BASE-TX ports and
2 x 10/100/1000BASE-TX ports (Gigabit)
Shielded connectors RJ45
Medium Shielded twisted pair, category CAT 5E
Total length of pair
100 m
Gigabit ports
ber optic
(with SFP ber module to
be mounted on SFP
connector)
Number and type 2 x
1000BASE-SX
ports (1)
2 x
1000BASE-LH
ports (2)
2 x
1000BASE-LX
ports (3)
Connectors LC
Medium Multi-mode
optical ber
Single mode
optical ber
Single mode
and multimode
optical ber
Length of optical ber
50/125 µm ber 550 m 550 m
62.2/125 µm ber 275 m 550 m
9/125 µm ber 8 -72,000 m 20,000 m
Attenuation analysis
50/125 µm ber 7.5 dB 11 dB
62.2/125 µm ber 7.5 dB 11 dB
9/125 µm ber 6 - 22 dB 11 dB
Ethernet services FDR, SMTP V3, SNTP client, multicast ltering for optimization of the Global Data protocol,
conguration via Web access
VLAN, IGMP Snooping, RSTP (Rapid Scanning Tree Protocol), priority port, data stream
control, secure port
Topology Number of switches Cascaded Unlimited
Redundant in a ring max. 50
Redundancy Redundant power supplies, redundant single ring, ring coupling
Power supply Voltage Operation 9.6...60 V c/18…30 V a, safety extra low voltage (SELV)
Power consumption 8.9 W + 1 W per SFP ber module 8.3 W
Removable connector 6-way
Operating temperature 0…+ 60 °C
Relative humidity 10… 90% non condensing
Degree of protection IP 20
Dimensions W x H x D 111 x 131 x 111 mm
Mounting On symmetrical DIN rail, 35 mm wide
Weight 0.410 kg
Conformity to standards cUL 60950, UL 508 and CSA 22.2 No. 142, UL 1604 and CSA 22.2 No. 213 Class 1 Division 2,
e, GL
LED indicators Power supply status, alarm relay status, active redundancy, redundancy management,
ber port status and ber port activity
Alarm relay Detected power supply fault, detected Ethernet network fault, or detected communication port
fault (1 A max. volt-free contact at 24 V c)
Reference TCS ESM 103F2LG0 TCS ESM 103F23G0
(1) With TCS EAA F1LFU00 ber optic module to be ordered separately, see page 79.
(2) With TCS EAA F1LFH00 ber optic module to be ordered separately, see page 79.
(3) With TCS EAA F1LFS00 ber optic module to be ordered separately, see page 79.
Product data sheet
(continued)
1
2
3
4
5
6
7
8
9
10
90
Modicon Momentum
automation platform
Concept programming software
Introduction
Introduction
Concept software is a conguration and application programming tool for the
Modicon Quantum and Modicon Momentum automation platforms. It is
Windows-based software that can be run on a standard PC. The conguration task
can be carried out online (with the PC connected to the Quantum processor) or
ofine (PC only). Concept supports the conguration by recommending only
permissible combinations. During online operation, the congured hardware is
checked immediately for validity, and illegal statements are rejected.
Concept editors support ve IEC programming languages:
b Function Block Diagram (FBD) language
b Ladder (LD)
b Sequential Function Chart (SFC) and Grafcet language
b Instruction List (IL)
b Structured Text (ST)
Also supported is ladder logic (LL984) that is compatible with Modsoft. IEC 61131-3
compliant data types are also available. With the data type editor, custom data types
can be converted to and from the IEC data types.
The basic elements of the FBD programming language are functions and function
blocks that can be combined to create a logical unit. The same basic elements are
used in the LD programming language; LD provides contact and coil elements.
The Grafcet SFC programming language (SFC) uses basic step, transition,
connection, branch, join and jump elements. The IL and ST text programming
languages use instructions, expressions, and key words. The LL984 programming
language uses an instruction set and contact and coil elements.
Programs can be written in logical segments. A segment can be a functional unit,
such as conveyor belt control. Only one programming language is used within a
given segment. You build the control program, which the automation device uses to
control the process, by combining segments within one program. Within the
program, IEC segments (written in FBD, LD, SFC, IL and ST) can be merged. The
LL984 segments are always processed as a block by the IEC segments. Concept’s
sophisticated user interface uses windows and menus for easy navigation.
Commands can be selected and executed quickly and easily using a mouse.
Context-sensitive help is available at each editing step.
PLC conguration
Variables for linking basic objects within one section are not required by the graphic
programming languages (FBD, LD, SFC and LL984).
These wiring diagrams are managed by the system, which minimizes any
conguration effort. Other variables, such as variables for data transfers between
different sections, are congured with the variables editor. With the data type editor,
custom data types can be derived from existing data types.
1
2
3
4
5
6
7
8
9
10
91
Modicon Momentum
automation platform
Concept programming software
Functions
Concept software provides an editor for each programming language. These
editors contain custom menus and tool bars. You can select the editor to be used as
you create each program segment.
In addition to the language editors, Concept provides a data type editor, a variables
editor and a reference data editor.
Function Block Diagram (FBD) language
With the IEC 61131-3 function block diagram language, you can combine elementary
functions, elementary function blocks (EFBs) and derived function blocks (known as
FFBs) with variables in an FBD.
FFBs and variables can be commented. Text can be freely placed within the graphic.
Many FFBs offer an option for input extensions.
Concept provides various block libraries with predened EFBs for programming an
FBD. EFBs are grouped in the libraries according to application types to facilitate the
search.
In the FBD editor, you can display, modify and load initial values, and current values
can be displayed. The CONT_CTL control library allows you to display animated
diagrams of the FFBs and a graph of the current values.
For custom function blocks (DFBs), the Concept-DFB editor is used. In this editor,
you can create your own function blocks from EFBs or existing DFBs. DFBs created
in the FBD editor can be recalled in the LD, IL and ST editors, and DFBs created in
the LD, IL and ST editors can be used in the FBD editor.
Ladder (LD)
With the IEC 61131-3 ladder diagram language, you can build an LD program with
elementary functions, function blocks and derived function blocks (known as FFBs),
along with contacts, coils and variables. FFBs, contacts, coils and variables can be
commented. Text can be freely placed within the graphic. Many FFBs offer an option
for input extensions.
The structure of an LD segment corresponds to that of a current path for relay
circuits. On its left side is a left bus bar, which corresponds to the phase (L
conductor) of a current path. As with a current path, only the LD objects (contacts,
coils) connected to a power supply (i.e., connected to the left bus bar) are processed
in LD programming. The right bus bar, which corresponds to the neutral conductor,
is not visible. However, coils and FFB outputs are internally connected it to create a
current ow.
The same EFB block libraries available for the FBD editor can be used in the LD
editor to program a ladder diagram.
In the FBD editor, you can display, modify and load initial values; current values can
be displayed. The CONT_CTL control library, for example allows you to display
animated diagrams of the FFBs, along with a graph of the current values.
For custom function blocks (DFBs), the Concept-DFB editor is used. In this editor,
you can create your own function blocks from EFBs or existing DFBs. DFBs created
in the LD editor can be recalled in the FBD, IL and ST editors, and DFBs created in
the FDB, IL and ST editors can be used in the LD editor.
Functions
1
2
3
4
5
6
7
8
9
10
92
Modicon Momentum
automation platform
Concept programming software
Functions
Sequential Function Chart (SFC) language
With the IEC 61131-3 sequential function chart (SFC) language, you can dene a
series of SFC objects that comprise a control sequence. Steps, transitions and
jumps in the sequence can be commented. Text can be freely placed within the
graphics. You can assign any number of actions to every step. A series of monitoring
functions e.g., maximum and minimum monitoring time – can be integrated into
each step’s specications. The actions can be assigned an attribute symbol (as
required by IEC) to control the action’s performance after it has been activated
e.g., a variable can be set to remain active after exiting.
Instruction List (IL)
With the IEC 61131-3 IL language, you can call entire functions and function blocks
conditionally or unconditionally, execute assignments and make conditional and
unconditional jumps within a program segment.
IL is a text-based language, and standard Windows word processing tools can be
used to generate code. The IL editor also provides several word processing
commands. Keywords, separators and comments are spell-checked automatically
as they are entered. Detected errors are highlighted in color.
For custom function blocks (DFBs), the Concept-DFB editor is used. In this editor,
you can create your own function blocks from EFBs or existing DFBs. DFBs created
in the IL editor can be recalled in the ST, LD, and FBD, DFBs created in the ST, LD,
and FBD editors can be recalled in the IL editor.
Structured Text (ST)
With the IEC 61131-3 ST language, you can call function blocks, execute functions
and assignments and conditionally execute and repeat instructions. The ST
programming environment is similar to Pascal. IL is a text-based language, and
therefore standard Windows word processing tools can be used to generate code.
The ST editor also provides several word processing commands. Keywords,
separators and comments are spell-checked automatically as they are entered.
Detected errors are highlighted in color.
Custom function blocks (DFBs) created with the ST editor can be called in the IL,
LD and FBD editors; DFBs created in the IL, LD and FBD editors can be used in the
ST editor.
Functions (continued)
1
2
3
4
5
6
7
8
9
10
93
Modicon Momentum
automation platform
Concept programming software
Functions (continued)
Functions
Data type editor
The data type editor denes new derived data types. Any elementary data types and
derived data types already existing in a project can be used for dening new data
types. With derived data types, various block parameters can be transferred as one
set. Within the program, this set is divided again into single parameters, processed,
then output as either a parameter set or individual parameters. Derived data types
are dened in text format, and standard Windows word processing tools can be
used. The data type editor also provides several word processing commands.
Variables editor
The variables editor contains input options for:
b Variable type (located variable, unlocated variable, constant)
b Symbolic name
b Data type
b Direct address (explicit, if desired)
b Comments
b Identication as human-machine interface (HMI) variable for data exchange
Animation tables editor
In online mode, the reference data editor displays, forces and controls variables.
The editor contains the following options:
b Default values for the variable
b Status display for the variable
b Various format denitions
b Ability to isolate the variable from the process
1
2
3
4
5
6
7
8
9
10
94
Modicon Momentum
automation platform
Concept programming software
Functions (continued) 0
Functions
Libraries
IEC library
The IEC library contains the EFBs dened in IEC 61131-3 (calculations, counters,
timers, etc).
Extended library
The extended library contains useful supplements to various libraries. It provides
EFBs for mean value creation, maximum value selection, negation, triggering,
converting, building a traverse with interpolation of the rst order, edge detection and
determination of the neutral range for process variables.
System library
The system library contains EFBs in support of system functions. It provides EFBs
for cycle time detection, utilization of various system clocks, control of SFC sections
and system status display.
CLC and CLC_PRO library
The Continuous Control library can be used to set up process-specic control
loops. In particular, it offers controller, derivative and integral control functions.
The CLC_PRO library contains the same EFBs as the CLC library along with data
structures.
Communication library
The communication libraries of built-in function blocks provide easy integration of
programs that allow communication between PLCs or HMI devices from within the
PLC’s application program. Like other function blocks, these EFBs can be used in
any language to share data, or provide data to the HMI device for display to the
operator.
Diagnostics library
The diagnostics library is used for troubleshooting the control program. It contains
EFBs for action, reaction,interlocking, and process prerequisite diagnostics, along
with signal monitoring.
LIB984 library
The LIB984 library provides common function blocks used in both the 984 ladder
logic editor and the IEC languages. This allows for easy transition of portions of
application code from the LL984 environment to the IEC environment.
Fuzzy logic library
The fuzzy library contains EFBs for fuzzy logic.
Analog I/O library
The ANA_IO library is used to process analog values.
1
2
3
4
5
6
7
8
9
10
95
Modicon Momentum
automation platform
Concept programming software
References
References
Concept packages
Description License type Reference Weight
kg
Concept S Version 2.6 Single (1 station)
372 SPU 471 0
1
V26
Concept M Version 2.6 Single (1 station)
372 SPU 472 0
1
V26
Concept XL Version 2.6 Single (1 station)
372 SPU 474 0
1
V26
Group (3 stations)
372 SPU 474 1
1
V26
Team (10 stations)
372 SPU 474 2
1
V26
Site (network)
372 SPU 474 3
1
V26
Concept EFB Toolkit
Version 2.6
Single (1 station)
332 SPU 470 01 V26
HVAC Function Blocks Library Site (network)
372 HVA 160 30V25
Concept maintenance and diagnostics packages
Description License type Reference Weight
kg
Concept Application Loader
Version 2.6
Single (1 station)
372 SPU 477 01 V26
Concept Updates
Description License type Reference Weight
kg
Concept XL Version p.p
to Concept XL V 2.6
Single (1 station) 372 ESS 474 01
Group (3 stations) 372 ESS 474 03
Team (10 stations) 372 ESS 474 10
Site (network) 372 ESS 474 00
Concept S Version p.p
to Concept S V 2.6
Single (1 station)
372 ESS 471 01
Concept M Version p.p
to Concept M V 2.6
Single (1 station)
372 ESS 472 01
Modsoft version p.p
to Concept XL V 2.6
Depends on number of
users
372 ESS 485 01
Concept EFB Toolkit
version p.p to version 2.6
372 ESS 470 01
Concept Documentation
Description Number of volumes Reference
(1)
Weight
kg
Installation 1840 USE 492 0p
Programming
3840 USE 493 0p
Concept IEC Block library 13 840 USE 494 0p
Concept 984 LL Block Library 2840 USE 496 0p
Concept EFB Tool User Manual 1840 USE 495 01
(1) p = Denes the documentation language: 0 English, 1 French, 2 German, and 3 Spanish.
1
2
3
4
5
6
7
8
9
10
96
Modicon Momentum
automation platform
ProWORX 32 programming software
Introduction
ProWORX 32 LL984 programming software is a full-featured, Modicon Quantum
and Modicon Momentum M1/M1E PLC programming software that is compatible
with Windows platforms (98/NT/2000/XP). ProWORX 32 gives you the power to
program your Modicon controllers online or ofine, manage your I/O subsystems,
and analyze your plant’s activity in real time.
ProWORX 32 offers client-server functions for organizing groups and user rights,
centralizing project backup, and serving as a bridge between design department and
workshop. The project emulator makes it possible to test projects before executing
them in a PLC operating environment, to help ensure optimal system effectiveness
at all times.
Some of the new ProWORX 32 features include:
b 32-bit processing. With 32-bit processing, ProWORX 32 is an even more
powerful solution than its predecessors, ProWORX Plus and ProWORX NxT.
32-bit processing lets you utilize the power of state-of-the-art operating systems
for optimal development and operational performance.
b A comprehensive suite of tools. ProWORX 32 provides everything you will
need to start, congure, test and complete your project, quickly, reliably and
professionally. And with its improved suite of standard utilities, ProWORX 32 is a
virtual “one stop shop” for your Automation requirements. No more searching on
the web for special features or functions, they’re included to save you time and
increase your productivity.
b A high-performance offer. In addition, ProWORX 32 will simplify and speed up
your system development and commissioning time with powerful diagnostics,
easier integration, and greater openness and exibility.
b Easier integration. Using standard Microsoft components, ProWORX 32 opens
up a wealth of user data. Import and export capabilities have been enhanced to
provide a variety of integration options for HMI and third party devices, such as a
built in “Alliance Tool” that allows users to create hardware proles for newly
developed devices. The proles can even be sent electronically to Schneider
Electric for inclusion in future ProWORX 32 releases.
Windows environment
The familiar Windows-based programming environment means you spend less time
learning how to do things, and more time being productive. ProWORX uses familiar
Windows features like user-dened screens, drag-and-drop, cut and paste, search,
and global replace.
Conversion
484 PLC code to 984 PLC code in one step! The most exible conversion tools
available in the automation industry. That is the reputation ProWORX products have
always enjoyed, and ProWORX 32 is no exception. With the ability to convert from
older project databases to this latest tool, ProWORX 32 supports almost 30 years of
PLC heritage.
Multiple projects
Imagine the time and effort you could save by testing a new project with an existing
project while it is running live. Now you can with the Multiple Projects function of
ProWORX 32, even with two PLCs running simultaneously! Perform diagnostic
checks to validate interdependencies between your emulated project and your live
applications, in real time, so you can go live with total condence.
Intuitive register editor
A powerful analysis tool, the Data Watch Window shows you information from your
plant in real time, or logs it to disk for in-depth historical analysis later on. Easily get
the data you need to make informed, effective production decisions. View and edit
data in full page display, see trends and track data points against time in a
spreadsheet, and monitor any combinations of discrete and analog data.
References:
page 99
Introduction
1
2
3
4
5
6
7
8
9
10
97
Modicon Momentum
automation platform
ProWORX 32 programming software
Introduction
I/O drawing generator
Save hours of painstaking effort with ProWORX 32’s I/O Drawing Generator, that
automatically creates wiring diagrams for the I/O cards dened in the Trafc Cop.
Generate necessary drawings all at once, or just one card at a time. Simply select an
address the I/O card uses with the Network Editor, then click the drawing button on
the Hardware Back Referencing panel to display the diagram. If desired, save it as
an AUTOCAD-compatible .DXF le or print it.
Network editor
With the Network Editor, ProWORX 32 reduces development time by using the same
commands and instructions for every controller. Simply cut, copy, and paste
networks from one platform to any other.
Program documentation
ProWORX is rst-class software with high-quality program documentation. Use one
of the many standard templates to get started, and progress to assemble your own
custom documentation. For better references and easier-to-use documentation, we
have provided annotation down to the “Bit” level to allow longer comments and more
lines of text. Even simple things like using Windows O/S fonts to help eliminate
printer issues demonstrates that every detail has been considered.
Realtime network status
Find the controller you need quickly and simplify network diagnostics with ProWORX
32’s powerful Network Scan feature. Network Scan searches your Modbus or
Modbus Plus networks, then identies and graphically displays each device found
and shows its status.
Advanced I/O management
Ensure that the l/O card you are conguring in the software matches the one on your
plant oor with ProWORX 32’s graphical Trafc Cop. It displays I/O cards on your
screen the same way they look in real life, which helps eliminate confusion. To place
a card, just select it from the convenient drop down menu and then drag it into the
controller slot you want. To save even more time, the Trafc Cop automatically
associates the card’s I/O points with a block of free addresses in your controller.
Once congured, manage your I/O with Pro WORX 32’s complete documentation
tools, with references for each head, drop, rack, slot and address. And, the Trafc
Cop’s graphical display shows you at-a-glance that your I/O is healthy.
References:
page 99
Introduction (continued)
1
2
3
4
5
6
7
8
9
10
98
Modicon Momentum
automation platform
ProWORX 32 programming software
Introduction
Client/Server Tools
ProWORX 32 allows projects to be developed in a collaborative environment
without sacricing control and security by utilizing the ProWORX 32 server as the
central repository for projects, the center for security, and the hub for
communications. The system administrator has total control over user accounts,
user groups, passwords, rights, and auditing policies and can grant access when
and where needed.
The client/server relationship allows projects to be skillfully managed and controlled.
The server can be used to keep “Master” versions of PLC projects for editing (subject
to rights), while editing is achieved using the client. This can be done via a stand alone
PC or even on the server, since both client and server can reside on the same PC.
The server has the capability to schedule software backups of the controller, detect
software modications, and store multiple versions. Even more powerful is the ability
to communicate from the client to the server using either Ethernet TCP/IP or
Modbus Plus.
Project Emulator
The project emulator is a very powerful tool that will help save considerable time in
the design and testing of your system. It provides the ability to test projects prior to
running them in the PLC run-time environment to help ensure your system will run
at peak efciency immediately upon commissioning. Two emulators are provided
that test interdependent projects. They are used to test communications, including:
I/O polling and monitoring network activities between projects.
Material List Generation
Want a shopping list for your PLC equipment? The Material List Generation function
automatically creates a list for the project, either online or ofine, even taking into
account the contents of the Trafc Cop. Add prices and comments once the list is
generated, saving you time and insuring that required components are fully
documented and identied.
Introduction (continued)
1
2
3
4
5
6
7
8
9
10
99
Modicon Momentum
automation platform
ProWORX 32 programming software
ProWORX Client/Server software
ProWORX packages
Description Used with License type Reference Weight
kg
ProWORX 32 Server Single-station 372 SPU 780 01 PSEV
Client/Server Suite Single-station 372 SPU 780 01 PSSV
Client, design/operation Single-station 372 SPU 780 01 PDEV
Group (3 stations) 372 SPU 780 01 PSTH
Team (10 stations) 372 SPU 780 01 PSTE
Site 372 SPU 780 01 SITE
Run Time client Single-station 372 SPU 781 01 PONL
ProWORX 32 Lite Client, design/operation Single-station 372 SPU 710 01 PLDV
Group (3 stations) 372 SPU 710 01 PLTH
Team (10 stations) 372 SPU 710 01 PLTE
ProWORX 32
Upgrades
Client Single-station 372 SPU 784 01 LPUP
Additional multi-use 372 SPU 784 01 SEAT
Group (3 stations) 372 SPU 784 01 LPTH
Team (10 stations) 372 SPU 784 01 LPTE
Documentation
Description Language Reference Weight
kg
ProWORX 32 programming manuals English 372 SPU 780 01 EMAN
French 372 SPU 780 01 FMAN
German 372 SPU 780 01 DMAN
Spanish 372 SPU 780 01 SMAN
References
1
2
3
4
5
6
7
8
9
10
100
Modicon Momentum
automation platform
Aggressive environments protection
Optional conformal coating
Introduction
If your control system needs to operate in a corrosive environment, selected
Modicon Momentum modules can be ordered with a conformal coating applied to
components of the product. Conformal coating will extend the component’s life and
enhance its environmental performance capabilities.
Mixed owing gas (power on)
Standard Pollutant Parts/billion Modicon Momentum’s performance
EIA 364-65
level III
CI
2
20 (±5) Meets the standard
NO
2
200 (±50) Exceeds standard (1250 parts/billion)
H
2
S 100 (±20) Meets standard
ISA-S71.04
GX severe
CI
2
10 Exceeds standard (20 parts/billion)
NO
2
1250 Meets standard
H
2
S 50 Exceeds standard (100 parts/billion)
SO
2
300 Meets standard
Humidity (operating)
Standard Concentration (%) Modicon Momentum’s performance
IEC-68-2-3 93 @ 60 °C (140 °F) Meets standard
Salt mist (non-operating)
Standard Concentration (%) Modicon Momentum’s performance
IEC 68-2-11 5 (±1) Exceeds standard (5.7%)
Fungus resistance
Standard Modicon Momentum’s performance
MIL-I-46058C Designed to meet standard
Temperature cycling (operating)
Standard Cycles Modicon Momentum’s performance
IEC 68-2-14 100 @ 0…60 °C (32…140 °F) Meets standard
Dust (non-operating)
Standard Pollutant Weight (%) Modicon Momentum’s performance
EIA 364-TP91
(pending)
Silica 36 Meets standard
Calcite 29 Meets standard
Iron oxide 12 Meets standard
Alumina 8 Meets standard
Gypsum 5 Meets standard
Paper ber 3 Meets standard
Cotton ber 3 Meets standard
Polyester ber 2 Meets standard
Carbon black 1 Meets standard
Human hair 0.5 Meets standard
Cigarette ash 0.5 Meets standard
Introduction
1
2
3
4
5
6
7
8
9
10
101
Modicon Momentum
automation platform
Aggressive environments protection
Optional conformal coating
References
The following is a list of Modicon Momentum products that are available with
optional conformal coating.
Note: Please note that a “C” is appended to the standard reference for those Modicon
Momentum products.
Discrete I/O bases
Type of current Input voltage Modularity
(no. of points)
Conformity
EC 1131-2
Reference
Weight
kg
Discrete input bases 24 Vdc 16 (1 x 16) Type 1 170 ADI 340 00C 0.190
32 (2 x 16) Type 1 170 ADI 350 00C 0.200
Type of current Output voltage Modularity
(no. of points)
Current per
output
Reference
Weight
kg
Discrete output bases
solid state, protected
24 Vdc 16 (2 x 8) 0.5 A 170 ADO 340 00C 0.210
32 (2 x 16) 0.5 A 170 ADO 350 00C 0.210
Type of current Input
voltage
Output
voltage
Modularity
Input
Outputs, current Reference
Weight
kg
Discrete I/O bases 24 Vdc Type
1
24 Vdc
protected
solid state
16 I (1 x 16) 16 O (2 x 8) 0.5 A 170 ADM 350 10C 0.200
16 I (4 x 4) 8 O (2 x 4) 2 A 170 ADM 370 10C 0.220
24 Vdc Type
1
24/230 Vac
20/115 Vdc
relay
10 I (1 x 10) 8 O (2 x 4) 2 A 170 ADM 390 30C (1)
170 ADM 390 31C (2)
0.260
Analog I/O bases
Type Number of channels Ranges Reference
Weight
kg
Analog inputs 2 bits + sign 16 single-ended ± 5 V, ± 10 V, 4-20 mA 170 AAI 140 00C 0.215
Analog onputs 15 bits + sign 4, differential Pt 100, Pt 1000, NI 100
thermocouples B, E, J, K, N, R, S, T
170 AAI 520 40C 0.215
8, differential ± 5 V, ± 10 V, 1-5 V± 20 mA, 4-20 mA 170 AAI 030 00C 0.215
Analog outputs12 bits + sign 4 ± 10 V, 4-20 mA 170 AAO 921 00C 0.215
Type of discrete and analog I/O bases Reference
Weight
kg
Inputs Outputs
4 differential analog inputs
13 bits + sign
± 5 V, ± 10 V, 1-5 V
± 20 mA, 4-20 mA
2 analog ouputs
12 bits
0-20 mA
± 10 V
170 AMM 090 00C 0.240
4 discrete inputs 24 Vdc 2 discrete inputs 24 Vdc-0,5 A
Communication adapters
Description Specications Reference Weight
kg
Ethernet TCP/IP network 10 Mbit/s 170 ENT 110 02C 0.070
Modbus Plus network IEC format, non-redundant 170 PNT 110 01C 0.070
984 format, non-redundant 170 NEF 110 21C 0.070
FIPIO bus Bus manager Premium 170 FNT 110 20C 0.070
In t e r Bu s Generation 3 (SUPI 2) 170 INT 110 00C 0.070
Generation 4 (SUPI 3, version 2) 170 INT 110 03C 0.070
Probus DP9,6 kbit/s...12 Mbit/s 170 DNT 110 00C 0.070
M1/M1E processor adapters
Memories Comm Port(s) Clock Speed Reference Weight
kg
256 Ko RAM, 256 Ko Flash 1 Modbus, 1 I/O Bus 32 MHz 171 CCS 760 00C 0.042
512 Ko RAM, 256 Ko Flash 1 Modbus, 1 I/O Bus 32 MHz 171 CCC 760 10C 0.042
544 Ko RAM, 512 Ko Flash 1 Ethernet, 1 I/O Bus 50 MHz 171 CCC 960 20C 0.042
544 Ko RAM, 1 Mo Flash,
IEC Exec
1 Ethernet, 1 I/O Bus 50 MHz 171 CCC 960 30C 0.042
Option adapters
Memories Reference Weight
kg
Modbus Plus network Single port, Time-of-Day (TOD) and battery backup 172 PNN 210 22C 0.070
Modbus link 2 x RS 232/RS 485 ports, Time-of-Day (TOD) and battery backup 172 JNN 210 32C 0.070
(1) Operating voltage 24 Vdc.
(2) Output voltage 24 Vdc.
170 AAI pp0 p0C
171 CCC pp0 p0
172 PNN 210 22C
References
170 ENT 110 02C
1
2
3
4
5
6
7
8
9
10
102
Modicon Momentum
automation platform
Enhanced grounding system
Modicon Momentum communication adapter ground screw
Due to new In t e r Bu s standards for electrical noise immunity, a number of Modicon
Momentum products have been updated to include the enhanced grounding
system, that is required to meet the revised electrical noise immunity standard
(ability to pass a 2.2 kVDC electrical fast transient burst test).
This grounding system includes a ground screw located in the communication or
M1/M1E processor adapter, that is connected to a xed standoff-ground nut on the
printed circuit board, and to a standoff on selected Modicon Momentum I/O bases.
Note: This electrical noise immunity requirement applys only to systems that requires InterBus
certication, version 2, and not to any other communication network that Modicon Momentum I/O
currently uses. The standard electrical fast transient test for Modicon Momentum is 500 Vdc.
The following is a list of the Modicon Momentum modules that currently have been
updated to include the new grounding system:
b Communication adapters
b M1/M1E processor adapters and option adapters
b Discrete and analog I/O bases
References
Range Description Reference See
page
Communication
adapters
Ethernet TCP/IP 10/100 Mbits/s (V2) 170 ENT 110 01 49
Ethernet TCP/IP 10 Mbits/s (V1) 170 ENT 110 02 49
In t e r Bu s suPI 3 (V2) 170 INT 110 03 57
FIPIO bus (for Premium) (V2) 170 FNT 110 01 55
M1/M1E processor
adapters
64 K, 1 Modbus, 20 MHz 171 CCS 700 00 68
64 K, 1 Modbus, 32 MHz 171 CCS 700 10 68
64 K, 2 Modbus, 20 MHz 171 CCS 780 00 68
256 K, 1 Modbus, 1 I/O bus, 32 MHz 171 CCS 760 00 68
512 K, 1 Modbus, 1 I/O bus, 32 MHz 171 CCC 760 10 68
512 K, 2 Modbus, 32 MHz 171 CCC 780 10 68
544 K, 1 Modbus, 1 Ethernet, 50 MHz 171 CCC 980 20 68
544 K, 1 Ethernet, 1 I/O bus, 50 MHz 171 CCC 960 20 68
544 K, IEC Exec, 1 Modbus, 1 Ethernet,
50 MHz
171 CCC 980 30 68
544 K, IEC Exec, 1 Ethernet, 1 I/O bus,
50 MHz
171 CCC 960 30 68
Option adapters Modbus Plus, single port 172 PNN 210 22 75
Modbus Plus, dual redundant ports 172 PNN 260 22 75
RS 232/RS 485 serial port 172 JNN 210 32 75
Discrete input
bases
24 Vdc 16 inputs 170 ADI 340 00 19
24 Vdc 32 inputs 170 ADI 350 00 19
Discrete output
bases
24 Vdc 16 solid state outputs 0.5 A 170 ADO 340 00 19
24 Vdc 32 solid state outputs0.5 A 170 ADO 350 00 19
DC/AC 6 relay form “C” outputs 5 A 170 ADO 830 30 19
Discrete I/O bases 24 Vdc 16 inputs/16 outputs 0.5 A 170 ADM 350 10 19
24 Vdc 16 fast inputs/16 outputs 0.5 A 170 ADM 350 11 19
24 Vdc 16 inputs/16 outputs 0.5 A 170 ADM 350 15 19
24 Vdc 16 inputs wiring
check/12 outputs 0.5 A
170 ADM 390 10 19
24 Vdc 16 inputs/8 outputs 2 A 170 ADM 370 10 19
12...60 Vdc 16 inputs/16 ouputs 0.5 A 170 ADM 850 10 19
24 Vdc 10 inputs/AC or DC/8 relay 2A 170 ADM 390 30 19
170 ADM 390 31 19
170 ARM 370 30 19
Analog input
bases
16 single-ended inputs 12 bits + sign 170 AAI 140 00 34
8 differential inputs 15 bits + sign 170 AAI 030 00 34
Discrete and
analog I/O bases
4 differential analog inputs/2 analog outputs
4 discrete inputs/2 discrete outputs
170 AMM 090 00 34
170 AMM 090 01 34
6 analog inputs/4 analog outputs
8 discrete inputs/8 discrete outputs
170 ANR 120 90 34
170 ANR 120 91 34
Specialty I/O
bases
High-speed counter base, 2 independant
counters 200 kHz max.
170 AEC 920 00 42
I/O base with Modbus RS 485 communication
port and 120 Vac 6 inputs/3 outputs 0,5 A
170 ADM 540 80 42
2
5
1 Communication adapter cover
2 I/O base
3 Standard screw M3-6
4 Male-female standoff
5 Added standoff
Introduction,
references
3
1
4
1
2
3
4
5
6
7
8
9
10
103
Modicon Momentum
automation platform
User documentation
References
Description Language Reference Weight
kg
Modicon Momentum I/O bases user
guide
English 870 USE 002 00
French 870 USE 002 01
German 870 USE 002 02
Spanish 870 USE 002 03
High-Speed counter base
(170 AEC 920 00) user guide
English 870 USE 008 00
French 870 USE 008 01
German 870 USE 008 02
M1/M1E processor adapters
and option adapter user guide
English 870 USE 101 10
French 870 USE 101 11
German 870 USE 101 12
Spanish 870 USE 101 13
In t e r Bu s communication adapters
user guide
english 870 USE 010 00
French 870 USE 010 01
German 870 USE 010 02
Spanish 870 USE 010 03
In t e r Bu s communication adapter
user guide
English 870 USE 003 00
French 870 USE 003 01
Probus DP communication adapter
user guide
(includes the GSD conguration
software on 3.5” disk)
English 870 USE 004 00
French 870 USE 004 01
German 870 USE 004 02
Modbus Plus communication adapter,
170 PNT Series user guide
English 870 USE 103 00
French 870 USE 103 01
German 870 USE 103 02
Modbus Plus communication adapter,
170 NEF Series user guide
English 870 USE 111 00
FIPIO communication adapter
(170 FNT 110 00) user guide
English 870 USE 005 00
French 870 USE 005 01
German 870 USE 005 02
Spanish 870 USE 005 03
FIPIO communication adapter
(170 FNT 110 01) user guide
English 870 USE 105 00
French 870 USE 105 01
German 870 USE 105 02
Spanish 870 USE 105 03
FIPIO Bus / FIPway network
reference manual
English TSX DR FIP E
French TSX DR FIP F
German TSX DR FIP G
Spanish TSX DR FIP S
Modbus Plus network
planning and installation guide
English 890 USE 100 00
French 890 USE 100 01
German 890 USE 100 02
Spanish 890 USE 100 03
Modbus Plus network BM85 bridge
multiplexer user guide
English 890 USE 103 00
Ethernet TCP/IP network
10BASE-T and 100BASE-TX
English 490 USE 133 00
French 490 USE 133 01
German 490 USE 133 02
Spanish 490 USE 133 03
Modbus/TCP/IP Ethernet communication
adapter user guide
English 870 USE 114 00
French 870 USE 114 01
German 870 USE 114 02
Spanish 870 USE 114 03
XMIT Function Block version 3.0
user guide
English 840 USE 113 00
References
1
2
3
4
5
6
7
8
9
10
104
Technical information
Automation products certications
Services
In some countries, certication of certain electrical components is enforced by law.
A standard conformity certicate is then issued by the ofcial organization. Each
certied product must carry approval symbols when enforced. Use on board
merchant navy vessels generally requires prior approval (= certication) of an
electrical device by certain marine classication authorities.
Key Certication body Country
CSA Canadian Standards Association Canada
C-Tick Australian Communication Authority Australia
GOST Gost Standard Scientic Research Institute C.I.S., Russia
UL Underwriters Laboratories USA
Key Classication authority Country
IACS International Association of Classication Societies International
ABS American Bureau of Shipping USA
BV Bureau Veritas France
DNV Det Norske Veritas Norway
GL Germanischer Lloyd Germany
LR Lloyd’s Register United Kingdom
RINA Registro Italiano Navale Italy
RMRS Russian Maritime Register of Shipping C.I.S.
The table below shows the situation as of 01/03/2008 for certications obtained or pending
from organizations for base PLCs. An overview of certicates for Schneider Electric
products is available on our web site: www.schneider-electric.us
Product certications
Approvals
C-Tick
Hazardous
locations
Class I, Div 2 (1)
Certied
Pending
certication UL CSA ACA GOST ATEX TÜV Rheinland
USA Canada Australia CIS, Russia USA, Canada Europe
Modicon OTB
Modicon STB FM Cat 3 G
Modicon Telefast ABE 7
ConneXium(2)
Magelis iPC
, Magelis
XBT GTW
(3) UL
Magelis XBT GT CSA/UL Cat 3 G-D
Magelis XBT GK
Magelis XBT F/FC/HM/PM
Magelis XBT N/R CSA/UL Cat 3 G-D
Magelis XBT RT CSA/UL
Modicon M340CSA
Modicon Momentum
Modicon Premium(2) CSA
Modicon Quantum(2) FM (2)
Modicon Quantum Safety (2) CSA SIL3 (4)
Modicon TSX Micro
Phaseo(3) (5)
Twido(6) (6) CSA/UL (6)
(1) Hazardous locations: UL 1604, CSA 22.2 no. 213 or FM 3611, certied products are
acceptable for use in hazardous locations of Class I, division 2, groups A, B, C, D or
unclassied only.
(2) Depending on product, consult our web site: www.schneider-electric.us
(3) cULus North American certication (Canada and USA).
(4) Certied for use in applications up to and including SIL3 according to IEC 61508.
(5) Except Universal power supplies and Function modules: UL certication pending.
(6) Except TWD NOI 10M3 AS-Interface module, only e.
Local certications
BG Germany TSX DPZ 10D2A safety module (Modicon TSX Micro PLC).
TSX PAY 262/282 safety modules (Modicon Premium PLC).
SIMTARS Australia Modicon TSX Micro automation platform
Modicon Premium automation platform (PL7)
AS-Interface Europe TWD NOI 10M3 master module (Twido PLC).
TSX SAZ 10 master module (Modicon TSX Micro).
TSX SAY 1000 master modules (Modicon Premium).
1
2
3
4
5
6
7
8
9
10
105
Technical information
Automation products certications
Community regulations
Marine classication
Marine classication authorities
Certied
Pending
certication
ABS BV DNV GL LR RINA RMRS
USA France Norway Germany UK Italy C.I.S.
Modicon OTB
Modicon STB (1)
Modicon Telefast ABE 7
ConneXium(2)
Magelis iPC
Magelis iPC, Magelis XBT GTW (2) (2) (2) (2) (2) (2)
Magelis XBT GK
Magelis XBT F/FC/HM/PM
Magelis XBT N/R (2) (2) (2) (2)
Magelis XBT RT
Modicon M340
Modicon Momentum
Modicon Premium (3) (2) (2) (2) (2) (2) (2) (2)
Modicon Quantum(2) (2)
Modicon TSX Micro
Phaseo
Twido(4) (4) (4)
(1) Also meets US Navy requirements, ABS-NRV part 4.
(2) Depending on product, consult our web site: www.schneider-electric.us.
(3) Modicon Premium PLC, also KRS (Korean register of Shipping) certied.
(4) Exceptions: compact bases TWD LCpp 40DRF, Extreme base TWD LEDCK1,
I/O module TWD DAI 8DT, analog I/O modules TWD AMI 2LT/4LT/8HT, TWD ARI 8HT,
TWD AVO 2HT, TWD AMM 6HT, communication modules 499 TWD 01100, TWD NCO1M,
TWD NOI 10M3 and taps TWD XCA ISO/T3RJ.
Community regulations
European directives
The opening of European markets implies a harmonization of regulations in the
various European Union member states.
European Directives are documents used to remove obstacles to the free movement
of goods and their application is compulsory in the European Union.
Member states are obliged to transcribe each Directive into their national legislation
and, at the same time, to withdraw any conicting regulations.
The Directives, particularly those of a technical nature, only set objectives, called
“general requirements”.
The manufacturer must take necessary measures to help ensure that his products
conform to the requirements of each Directive relating to his equipment.
As a general rule, the manufacturer afrms that his product conforms to the
necessary requirements of the Directive(s) by applying the e label to his product.
The e marking is applied to Schneider-electric products where relevant.
The signicance of e marking
b The e marking on a product means that the manufacturer certies that this
product conforms to the relevant European Directives. It is necessary so that a
product subject to a Directive(s) can be marketed and freely moved within the
European Union.
b The e marking is intended solely for the national authorities responsible for
market regulation.
For electrical equipment, conformity of the product to standards indicates that it is
suitable for use.
One or more Directives, as appropriate, may apply to our products, in particular:
b The Low Voltage Directive 2006/95/EC
b The Electromagnetic Compatibility Directive 89/336/EEC, amended by Directives
2004/108/EC
b Directive e ATEX 94/9/EC
Services (continued)
1
2
3
4
5
6
7
8
9
10
106
Product reference index
0
043 509 383 53, 75
1
110 XCA 203 00 69, 75
110 XCA 204 00 69, 75
110 XCA 282 01 69, 75
110 XCA 282 02 69, 75
110 XCA 282 03 69, 75
170 AAI 030 00 34, 102
170 AAI 030 00C 101
170 AAI 140 00 34, 102
170 AAI 140 00C 101
170 AAI 520 40 34
170 AAI 520 40C 101
170 AAO 120 00 34
170 AAO 921 00 34
170 AAO 921 00C 101
170 ADI 340 00 19, 102
170 ADI 340 00C 101
170 ADI 350 00 19, 102
170 ADI 350 00C 101
170 ADI 540 50 19
170 ADI 740 50 19
170 ADM 350 10 19, 102
170 ADM 350 10C 101
170 ADM 350 11 19, 102
170 ADM 350 15 19, 102
170 ADM 370 10 19, 102
170 ADM 370 10C 101
170 ADM 390 10 19, 102
170 ADM 390 30 19, 102
170 ADM 390 30C 101
170 ADM 390 31 102
170 ADM 390 31C 101
170 ADM 540 80 42, 102
170 ADM 690 51 19
170 ADM 850 10 19, 102
170 ADO 340 00 19, 102
170 ADO 340 00C 101
170 ADO 350 00 19, 102
170 ADO 350 00C 101
170 ADO 530 50 19
170 ADO 540 50 19
170 ADO 730 50 19
170 ADO 740 50 19
170 ADO 830 30 19
170 ADO 830 30 102
170 AEC 920 00 42, 102
170 AMM 090 00 34, 102
170 AMM 090 00C 101
170 AMM 090 01 34, 102
170 ANR 120 90 34, 102
170 ANR 120 91 34, 102
170 ARM 370 30 19, 102
170 ARM 390 31 19
170 BDM 090 00 19, 35
170 BNO 671 01 57
170 BSM 016 00 19
170 DNT 110 00 59
170 DNT 110 00C 101
170 ENT 110 01 49, 102
170 ENT 110 02 49, 102
170 ENT 110 02C 101
170 FNT 110 00 55
170 FNT 110 01 55, 102
170 FNT 110 20C 101
170 INT 110 00 57
170 INT 110 00C 101
170 INT 110 03 57, 102
170 INT 110 03C 101
170 MCI 007 00 57
170 MCI 020 10 75
170 MCI 020 36 75
170 MCI 020 80 75
170 MCI 021 10 53
170 MCI 021 20 53, 75
170 MCI 021 36 53
170 MCI 021 80 53, 75
170 MCI 041 10 75
170 MCI 100 01 57
170 NEF 110 21 53
170 NEF 110 21C 101
170 NEF 160 21 53
170 PNT 110 01C 101
170 PNT 110 20 53
170 PNT 160 20 53
170 XCP 100 00 57
170 XCP 200 00 19, 35
170 XTS 001 00 19, 35
170 XTS 002 00 19, 35
170 XTS 003 01 19, 35
170 XTS 004 01 19, 35
170 XTS 005 01 19, 35
170 XTS 006 01 19, 35
170 XTS 007 01 19, 35
170 XTS 008 01 19, 35
170 XTS 009 00 57
170 XTS 020 00 53, 75
170 XTS 021 00 53, 69,
75
170 XTS 022 00 75
170 XTS 040 00 69, 75
170 XTS 041 00 75
170 XTS 042 00 75
170 XTS 100 00 19, 35,
42, 59
170 XTS 120 00 19
171 CCC 760 10 68, 102
171 CCC 760 10C 101
171 CCC 780 10 68, 102
171 CCC 960 20 68, 102
171 CCC 960 20C 101
171 CCC 960 30 68, 102
171 CCC 960 30C 101
171 CCC 980 20 68, 102
171 CCC 980 30 68, 102
171 CCS 700 00 68, 102
171 CCS 700 10 68, 102
171 CCS 760 00 68, 102
171 CCS 760 00C 101
171 CCS 780 00 68, 102
172 JNN 210 32 75, 102
172 JNN 210 32C 101
172 PNN 210 22 75, 102
172 PNN 210 22C 101
172 PNN 260 22 75, 102
3
332 SPU 470 01 V26 95
372 ESS 470 01 95
372 ESS 471 01 95
372 ESS 472 01 95
372 ESS 474 00 95
372 ESS 474 01 95
372 ESS 474 03 95
372 ESS 474 10 95
372 ESS 485 01 95
372 HVA 160 30 V25 95
372 SPU 471 01 V26 95
372 SPU 472 01 V26 95
372 SPU 474 01 V26 95
372 SPU 474 11 V26 95
372 SPU 474 21 V26 95
372 SPU 474 31 V26 95
372 SPU 477 01 V26 95
372 SPU 710 01 PLDV 99
372 SPU 710 01 PLTE 99
372 SPU 710 01 PLTH 99
372 SPU 780 01 DMAN 99
372 SPU 780 01 EMAN 99
372 SPU 780 01 FMAN 99
372 SPU 780 01 PDEV 99
372 SPU 780 01 PSEV 99
372 SPU 780 01 PSSV 99
372 SPU 780 01 PSTE 99
372 SPU 780 01 PSTH 99
372 SPU 780 01 SITE 99
372 SPU 780 01 SMAN 99
372 SPU 781 01 PONL 99
372 SPU 784 01 LPTE 99
372 SPU 784 01 LPTH 99
372 SPU 784 01 LPUP 99
372 SPU 784 01 SEAT 99
4
424 244 739 69, 75
490 NAA 271 01 53, 75
490 NAA 271 02 53, 75
490 NAA 271 03 53, 75
490 NAA 271 04 53, 75
490 NAA 271 06 53, 75
490 NAB 000 10 53
490 NAD 911 03 59
490 NAD 911 04 59
490 NAD 911 05 59
490 NOC 000 05 79
490 NOR 000 03 79
490 NOR 000 05 79
490 NOT 000 05 79
490 NTC 000 05 78
490 NTC 000 05U 78
490 NTC 000 15 78
490 NTC 000 40 78
490 NTC 000 40U 78
490 NTC 000 80 78
490 NTC 000 80U 78
490 NTW 000 02 78
490 NTW 000 02U 78
490 NTW 000 05 78
490 NTW 000 05U 78
490 NTW 000 12 78
490 NTW 000 12U 78
490 NTW 000 40 78
490 NTW 000 40U 78
490 NTW 000 80 78
490 NTW 000 80U 78
490 USE 133 00 103
490 USE 133 01 103
490 USE 133 02 103
490 USE 133 03 103
499 NEH 104 10 80
499 NES 181 00 82
499 NMS 251 01 84
499 NMS 251 02 84
499 NSS 251 01 84
499 NSS 251 02 84
499 NTR 101 00 81
8
840 USE 113 00 103
840 USE 492 0• 95
840 USE 493 0• 95
840 USE 494 0• 95
840 USE 495 01 95
840 USE 496 0• 95
870 USE 002 00 42, 103
870 USE 002 01 103
870 USE 002 02 103
870 USE 002 03 103
870 USE 003 00 103
870 USE 003 01 103
870 USE 004 00 103
870 USE 004 01 103
870 USE 004 02 103
870 USE 005 00 103
870 USE 005 01 103
870 USE 005 02 103
870 USE 005 03 103
870 USE 008 00 42, 103
870 USE 008 01 103
870 USE 008 02 103
870 USE 010 00 103
870 USE 010 01 103
870 USE 010 02 103
870 USE 010 03 103
870 USE 101 10 103
870 USE 101 11 103
870 USE 101 12 103
870 USE 101 13 103
870 USE 103 00 103
870 USE 103 01 103
870 USE 103 02 103
870 USE 105 00 103
1
2
3
4
5
6
7
8
9
10
107
Product reference index
870 USE 105 01 103
870 USE 105 02 103
870 USE 105 03 103
870 USE 111 00 103
870 USE 114 00 103
870 USE 114 01 103
870 USE 114 02 103
870 USE 114 03 103
890 USE 100 00 103
890 USE 100 01 103
890 USE 100 02 103
890 USE 100 03 103
890 USE 103 00 103
9
900 NAD 211 10 53, 75
990 NAD 211 30 53, 75
990 NAD 218 10 53
990 NAD 218 30 53
990 NAD 219 10 53
990 NAD 219 30 53
990 NAD 230 00 53, 75
990 NAD 230 10 53, 75
990 NAD 230 11 53, 75
990 NAD 230 20 53
990 NAD 230 21 53
990 NAD 230 22 53
A
AS MBKT 085 53, 75
AS MBKT 185 75
C
CER 001 19, 35
K
KAB 3225 LI 57
KAB PROFIB 59
T
TCS EAA F11F13F00 79
TCS EAA F1LFH00 79
TCS EAA F1LFS00 79
TCS EAA F1LFU00 79
TCS EAM 0100 79
TCS ECL 1M1M 10S2 79
TCS ECL 1M1M 1S2 79
TCS ECL 1M1M 25S2 79
TCS ECL 1M1M 3S2 79
TCS ECL 1M1M 40S2 79
TCS ECL 1M3M 10S2 79
TCS ECL 1M3M 1S2 79
TCS ECL 1M3M 25S2 79
TCS ECL 1M3M 3S2 79
TCS ECL 1M3M 40S2 79
TCS ECN 300R2 78
TCS EK1 MDRS 78
TCS EK3 MDS 78
TCS ESM 043F1CS0 85
TCS ESM 043F1CU0 85
TCS ESM 043F2CS0 85
TCS ESM 043F2CU0 85
TCS ESM 103F23G0 89
TCS ESM 103F2LG0 89
TCS ESM 043F23F0 86
TCS ESM 083F1CS0 87
TCS ESM 083F1CU0 87
TCS ESM 083F23F0 86
TCS ESM 083F2CS0 87
TCS ESM 083F2CU0 87
TCS ESM 163F23F0 88
TCS ESM 163F2CU0 88
TCS ESM 243F2CU0 88
TCS ESU 033FN0 83
TCS ESU 043F1N0 83
TCS ESU 051F0 82
TCS ESU 053FN0 83
TSX DR FIP E 103
TSX DR FIP F 103
TSX DR FIP G 103
TSX DR FIP S 103
TSX FP ACC 12 55
TSX FP ACC 14 55
TSX FP ACC 2 55
TSX FP ACC 4 55
TSX FP CC 100 55
TSX FP CC 200 55
TSX FP CC 500 55
TSX IBS CA 100 57
TSX IBS CA 400 57
TSX PBS CA 100 59
TSX PBS CA 400 59
X
XZC C12 FCM 50B 79, 82
XZC C12 FDM 50B 79, 82
XZC P1164L2 79, 82
XZC P1164L5 79, 82
XZC P1264L2 79, 82
XZC P1264L5 79, 82
01/2011
MKTED205061EN-US
The information and dimensions in this catalog are provided for the convenience of our customers.
While this information is believed to be accurate, Schneider Electric reserves the right to make
updates and changes without prior notication and assumes no liability for any errors or omissions.
Design: Schneider Electric
Photos: Schneider Electric
© 2011 Schneider Electric. All rights reser ved.
Schneider Electric USA, Inc. http://www.schneider-electric.us/
80 01 Knightdale Blvd.
Knightdale, NC 27545
Tel: 919-266-3671
19 Waterman Avenue
Toronto, Ontario M4B 1Y2
Tel: 416-752-8020
Schneider Electric Canada
Modicon Momentum automation platform
2011