GB DELTA profil Pushbutton single Pushbutton double Pushbutton quadruple DELTA style Pushbutton single Pushbutton double Pushbutton quadruple UP 241 UP 242 UP 243 UP 244 UP 245 UP 246 UP 285 UP 286 UP 287 5WG1 241-2AB_1 5WG1 242-2AB_1 5WG1 243-2AB_1 5WG1 244-2AB_1 5WG1 245-2AB_1 5WG1 246-2AB_1 5WG1 285-2AB_1 5WG1 286-2AB_1 5WG1 287-2AB_1 As at: March 2008 Operating and mounting instructions Products Pushbutton single DELTA profil: Frame Pushbutton quadruple Pushbutton double DELTA style: Bus coupling unit cut-out frames ordered separately from the DELTA ranges frames ordered separately from the DELTA ranges bus coupling unit UP 110 or UP 114 ordered separately C5 C1 C2 C3 C4 C5 C6 C7 C1 C6 C5 C2 C4 C3 C6 Bus coupling unit Frame Fixing screws *) Basic pushbutton module *) Rockers *) Mounting rack *) Recess *) *) Scope of supply C7 C5 C4 C5 C3 C7 C6 C5 C4 C3 C7 C5 Diagram 1: Mounting the pushbutton Product and functional description There is an upper and a lower operating field on the pushbuttons. In the middle of the pushbutton there is a note panel in which pictograms can be inserted. This panel also contains display elements (LEDs) for orientation lighting and also for status indication. Opposing rockers are combined to form a pair e.g. for defined switching, dimming, controlling shutters and blinds. It is also possible to carry out the switching functions ON and OFF e.g. via a pushbutton "UP". Using an application program, the flush-mounted pushbuttons give commands via the flush-mounted bus coupler for example to actuators for defined switching on/off, for dimming lamps, raising/lowering shutters or for louvre adjustment or other parameterisable functional units. The device pushbutton is placed together with the relevant DELTA frame on the flush-mounted bus coupler and can only function in combination with the bus coupler UP and an appropriate application program, i.e. the pushbutton (with bus coupler UP) consist of the device (hardware) and the application program (software). The bus coupler UP and the relevant frame are not supplied with the device but must be ordered separately. Using the ETS program the application programs can be selected and the specific parameters and addresses can be assigned. Additional Informations http://www.siemens.com/gamma Technical data Power supply * via the flush-mounted bus coupler Operating elements * 1, 2 or 4 pairs of rockers, idle in the middle position Display elements * per pair of pushbuttons 1 LED red for status indication e.g. quadruple pushbutton = 4 LEDs red * 1 LED red for orientation light Connections * 10-pole plug connector (PEI): for connection to the flushmounted bus coupler Mechanical data * Dimensions: - DELTA profil (L x W x D ): 65 x 65 x 11 mm - DELTA style (L x W x D ): 68 x 68 x 14 mm * Weight: approx. 40 g Electrical safety * Type of protection (according to EN 60529): IP 20 Environmental conditions * Ambient operating temperature: - 5 ... + 45 C * Storage temperature: - 25 ... + 70 C * Relative humidity (not condensing): 5 % to 93 % Markings * KNX / EIB Please turn over ! Location and function of the operating and display elements DELTA style C5 C6 Pushbutton single C4 C3 A1 A2 A3 A5 A4 C7 C5 C1 C5 C2 1) C6 Pushbutton double 1) Insert the screwdriver between the frame and the pushbutton module 2) Swivel the screwdriver towards the wall. C4 C3 C7 C5 A1 2) Diagram 6: Lifting out the pictogram cover A2 A3 A5 C5 pictogram X) foundation pictogram C6 A4 foundation X) C4 C3 Pushbutton quadruple C7 C5 retaining tongue A1 A5 A2 A3 A4 Diagram 3: mounting sequence Drawing for mounting the fixing screws (C3) Diagram 7: inserting the pictograms * Snap on the pictogram cover (A5) again. Dismantling Diagram 2: Location of display and operating elements C7 A1 A2 A3 A4 A5 Upper operating field LEDs for status indication LED as an orientation light Lower operating field Cover for pictograms Without fixing screws * Remove the pushbutton (C4) completely together with the frame (C2) from the flush-mounted bus coupler (C1): a) with the mere hand b) with a screwdriver beneath the frame / wall Mounting b) a) Pushbutton single * The device can be used for permanent interior installations, in dry rooms and for insertion in flush-type boxes. V DANGER JJJJJJJJJJJJJJJJJJJJJJJJJJ * The device may only be installed and commissioned by an authorised electrician. * The device may not be inserted in the same box as 230 V devices. * The device may be used in switch sockets, if VDE approved devices have been used. * The prevailing safety and accident regulations must be observed. * The device may not be opened. * For planning and construction of electric installations, the relevant guidelines, regulations and standards of the respective country are to be considered. General description The pushbutton is placed together with the relevant frame on the flush-mounted bus coupler. The flush-mounted bus coupler (C1) is connected in the flush-type box and fixed in position (refer to the installation instructions for the bus coupler). Diagram 8: Dismantling With fixing screws Pushbutton double / pushbutton quadruple Holding down as shown with pushbutton single Diagram 4: Lifting out the rockers Inserting pictograms * Lift out the pictogram cover (A5) with the screwdriver by applying leverage, during this hold down the pushbutton module (C4). DELTA profil * Insert the screwdriver into the slot (A2) until it reaches the stop and then wiggle it. * Remove the rockers as described at Mounting / Using fixing screws". * Screw out the fixing screws (C3). * Snap on the rockers (C5) again. * Remove the whole pushbutton module (C4) as described at Without fixing screws ". General Notes * The operating instructions must be handed over to the client. * Any faulty device should be returned to the local Siemens office. * If you have further questions concerning the product please contact our technical support: ! ! " Mounting sequence +49 (180) 5050-222 +49 (180) 5050-223 www.siemens.com/automation/support-request * Place the basic pushbutton module (C4, diagram 3) with the relevant frame (C2) on the flush-mounted bus coupler (C1) and press the one strongly upon the other. Using fixing screws: * If the fixing screws (C3) are used first of all the rockers (C5) have to be lifted out altogether. This can be achieved by inserting the screwdriver between the frame in the recess (C7) and applying leverage (diagram 4). Important: The pushbutton module (C4, diagram 3) and the rockers (C5) together with the frame (C2) must be held down / pressed down. 1) 2) Diagram 5: Lifting out the pictogram cover * Lay the pictograms onto the foundation. * Snap on the pictogram cover (A5) again. * Screw down the fixing screws (C3). * The rockers (C5) have to be orientated properly and clicked upon the mounting rack (C6). 251523.41.11 DS04