Product datasheet
Characteristics
9012GAW6
pressure switch 9012G - adjustable scale - 2
thresholds - 5.0 to 250 psig
Discontinued
Commercial status
Discontinued on:01 November 2020
End-of-service on:03 November 2020
9012GAW6has not been replaced. Pleasecontact your
customer care centrefor more information.
Main
Range of product 9012G
Pressure sensor type Electromechanical pressure switch
Pressure sensor name 9012G
Pressure sensor size 1723.69kPa
Maximum pressure 750 psi
Contacts type and composition NC-NO, SPDT-DB, Form Z, snap action, silver nickel contacts
Controlled fluid Hydraulic oil (-40…121°C)
Non-corrosive liquids
Air
Non-corrosive gas
Fluid connection type 0.25 inch 18 NPTF conforming to UL 508
Pressure switch type of operation Regulation between 2 thresholds
Scale type Adjustable differential
Local display Without
Complementary
Range on decreasing pressure 34.47…1723.69kPa
Approx adjustable differential at mid
range
68.95…337.84kPa +/- 2.5 % full scale
Cable entry 0.5 inch NPT conduit entrance
Terminal block type 4 screw terminals
Electrical connection Screw-clamp terminals, AWG 22...AWG 12
Electrical circuit type Control circuit
Local signalling Without:
[In] rated current 3A 240 V AC A600 conforming to NEMA rating designation
6A 120 V AC A600 conforming to NEMA rating designation
0.27A 250 V DC Q600 conforming to NEMA rating designation
0.22A 125 V DC Q600 conforming to NEMA rating designation
Setting Internal