The M-Series is a low cost, miniature hydraulic/magnetic
circuit breakers ideally designed for demanding
applications requiring space saving features, aesthetics and
snap-in front panel mounting.
Its newest design features a compact, space saving,
vertically mounted parallel pole conguration, which
is UL489A listed up to 50 amps and is well suited for
telecommunication equipment tting in one rack unit.
Furthermore, it features two uniquely designed terminals
that provide the highest level of balanced circuit
protection.
In addition, these circuit breakers feature various styling
options allowing for design exibility. They are available
in choices of rocker actuator styles and colors, including
paddle and baton style handle actuators, push-to-reset
and push-pull pushbutton actuators, Visi-Rocker two color
actuators as well as non-illuminated or illuminated rocker
versions with LED or neon bulbs. The exclusive Rockerguard
bezel helps prevent inadvertent actuation and wiping
contact design insures long-term reliability. The M-Series
circuit breakers are available in 1 & 2 poles or parallel poles,
0.02 to 50 amps, up to 250VAC or 80VDC with choices of
time delays, terminals, panel hardware, actuator styles,
colors, and imprinting.
Features:
Parallel pole conguration well suited for one rack unit
Compact design
Applications:
Communication equipment
Vehicles
Marine
Generators
Power supplies
Medical equipment
M-Series
Circuit Breaker
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
2 |M-Series Circuit Breaker - General Specications
Environmental
Physical
Mechanical
Electrical
CURRENT TOLERANCE
(AMPS) (%)
0.10 - 20.0 ±25
20.1 - 50.0 ±35
Designed in accordance with requirements of specication
MIL PRF-55629 & MIL-STD-202G as follows:
*Manufacturer reserves the right to change product specification without prior notice.
RESISTANCE PER POLE VALUES
from Line to Load Terminals
(Values Based on Series Trip Circuit Breaker)
Maximum Voltage 125/250 VAC 50/60 Hz, 80 VDC
(See Rating Tables.)
Current Ratings Standard current coils: 0.100,
0.250, 0.500, 0.750, 1.00 thru 15.0
in 1 amp increments, 18.0, 20.0,
25.0, 30.0. Other ratings available
- see Ordering Scheme.
Auxiliary Switch Rating SPDT; 7A 250VAC, 7A (Res)
28VDC, 4A (Ind.) 28VDC, 0.25A
80VDC (Res) (silver contacts),
0.1A 125VAC (gold contacts).
Insulation Resistance Minimum of 100 Megohms at 500
VDC.
Dielectric Strength UL, CSA 1500V, 50/60 Hz for one
minute between all electrically
isolated terminals. M-Series
Circuit Breakers comply with the
8mm spacing and 3750 V 50/60Hz
dielectric requirements from
hazardous voltage to operator
accessible surfaces, per
Publications IEC 380, 435, 950,
EN 60950 and VDE 0805.
Resistance, Impedance Values from Line to Load Terminal
- based on Series Trip Circuit
Breaker.
Endurance 10,000 ON-OFF operations @ 6
per minute with rated Current and
Voltage.
Trip Free All M-Series Circuit Breakers will
trip on overload, even when
actuator is forcibly held in the ON
position.
Trip Indication The actuator moves positively
to the OFF position when an
overload causes the circuit
breaker to trip.
Shock Withstands 100 Gs, 6ms, sawtooth
while carrying rated current per
Method 213, Cond. I. Instantaneous
curves tested at 80% of rated
current.
Vibration Withstands 0.060” excursion
from 10-55 Hz, and 10 Gs 55-500
Hz, at rated current per Method
204C, Test Condition A.
Instantaneous curves tested at
80% of rated current.
Moisture Resistance Method 106D, i.e., ten 24-hour
cycles @ + 25°C to +65°C, 80-
98% RH.
Salt Spray Method 101, Condition A (90-95%
RH @ 5% NaCl Solution, 96 hrs).
Thermal Shock Method 107D, Condition A (Five
cycles @ -55°C to +25°C to +85°C
to +25°C).
Operating Temperature -40° C to +85° C
Chemical Resistance Only the outside surfaces of the
case and the handles may be
cleaned with detergents or
alcohol. Organic (hydrocarbon
based) solvents are not
recommended because they
attack plastics. Caution should
be taken when solvents are used
to clean and remove ux from
terminals. Lubricants should not
be introduced into the handle/
bushing openings
Number of Poles 1 or 2
Internal Circuit Congs. Series with or without
Auxiliary Switch.
Switch Only with or without
Auxiliary Switch.
Weight Approximately 30 grams/pole
(Approximately 1.07 ounces/pole)
Standard Colors See Ordering Scheme.a
Pulse Tolerance Curves
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 3 M-Series Circuit Breaker - General Specications
Electrical Tables
Table A: Lists UL Recognized and CSA Accepted congurations & performance capabilities as a Component Supplementary
Protector.
Table B: Lists UL Recognized,CSA Accepted and TUV and VDE Certied congurations and performance capabilities as a
Component Supplementary Protector.
Table B Notes:
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 TUV only, not VDE
5 Requires backup protection with a thermal magnetic circuit breaker rated 32 amps and having a Type C trip characteristic per
EN60898/DIN VDE 0641 (C32A) for ratings greater than 15amps, and a thermal magnetic circuit breaker rated 16 amps and
having a Type C trip characteristic per EN60898/DIN VDE 0641 (C16A) for ratings 15 amps and less
Table A Notes:
1 Polarity Sensitive
2 Available only with Special Catalog Number. Consult Factory.
3 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 30 Amps maximum
4 Requires Branch Circuit Backup with a UL Listed type K-5 or RK-5 fuse rated 60 Amps maximum
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
4 |
M-SERIES TABLE C: UL489A Listed
WITHOUT BACKUP
FUSE
UL489A
80 DC 31-50 2 600
65 1DC 31-50 2 1000
1. Available only with Special Catalog Number. Consult Factory.
POLES
BREAKING
INTERRUPTING
CAPACITY (AMPS)
M-SERIES TABLE D: Parallel Pole Construction UL489A Listed
(COMMUNICATIONS EQUIPMENT - POLARITY SENSITIVE)
SERIES
CIRCUIT
CONFIGURATION
MAX. RATING FREQUENCY
VOLTAGE CURRENT
RATING
GENERAL
PURPOSE
AMPS
M-Series Circuit Breaker - General Specications
Electrical Tables
Table C: Lists UL489A Listed and TUV Certied congurations and performance capabilities for use in Communications Equipment.
Table D: Lists UL489A Listed congurations and performance capabilities for use in Communications Equipment.
Table C Notes:
1 Available only with Special Caralog Number
Table D Notes:
1 Available only with Special Caralog Number
Agency Certifications
UL Recognized
UL Standard 1077
UL Listed
UL Standard 489A
CSA Accepted
VDE Certied
TUV Certied
Component Recognition Program
as Protectors, Supplementary
(Guide CCN/QVNU2, File E75596)
Communications Equipment
(Guide CCN/DITT, File E189195)
Component Supplementary
Protector (Class 3215 30, File
047848 0 000)
CSA Standard C22.2 No. 235
EN60934, VDE 0642 under File
10537
EN60934, under License No.
R9671109
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 5 M-Series Parallel Pole Rocker - Ordering Scheme
6 CURRENT RATING (AMPERES)
631 31.000
635 35.000
640 40.000
645 45.000
650 50.000
CODE AMPERES
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Illumination
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M E P A5 22 1 TB
D2 650
1 SERIES
M
7 TERMINAL
A Push in Stud
5 10-32 Screw (Bus Type)
3 POLES
2 Two
4 CIRCUIT/AUXILIARY SWITCH2
P Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Q Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
with Auxiliary Switch, Gold Contacts
R Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
5 FREQUENCY & TIME DELAY
D2 DC Short
D4 DC Medium
12 AGENCY APPROVAL
T UL 489A Listed
11 BEZEL COLOR
A White without Rockerguard
B Black without Rockerguard
G Gray without Rockerguard
1 White with Rockerguard
2 Black with Rockerguard
7 Gray with Rockerguard
9
Actuator
Color &
Legend
10
Legend
11
Bezel
Color
8 ILLUMINATION
Non-Illuminated
A Non-Illuminated
9 ACTUATOR COLOR & LEGEND
Actuator Visi1 Legend
1 White Black
2 Black White
3 Red White
4 Green White
5 Blue White
6 Yellow Black
7 Gray Black
8 Orange Black
10 LEGEND
2 ON - OFF Vertical
3 ON - OFF Horizontal
6 Dual Vertical
7 Dual Horizontal
2 ACTUATOR
Single Color Rocker Two Color Visi-Rocker Single Color Translucent Rocker
A Angled D Indicate ON F Angled
B Flat E Indicate OFF G Flat
Notes:
1 Reminder of Rocker same color as Visi
2 Aux Switch only available with screw terminals
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
6 |M-Series Parallel Pole - Handle / Push Button - Ordering Scheme
6 CURRENT RATING (AMPERES)
631 31.000
635 35.000
640 40.000
645 45.000
650 50.000
CODE AMPERES
1 SERIES
M
7 TERMINAL
A Push in Stud
5 10-32 Screw (Bus Type)
3 POLES
2 Two
4 CIRCUIT/AUXILIARY SWITCH1
P Series Trip Current (Parallel Pole)
with Auxiliary Switch, Silver Contacts
Q Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
with Auxiliary Switch, Gold Contacts
R Series Trip Current (Parallel Pole) .110 x 0.20 Q.C
5 FREQUENCY & TIME DELAY
D2 DC Short
D4 DC Medium
12 AGENCY APPROVAL
T UL 489A Listed
11 BUSHING COLOR
B Black
9 FRONT PANEL HARDWARE
Handle
A No outer Panel Hardware
B Knurled Nut, Bright Nickel
C Knurled Nut, Bright Nickel w/Locking Ring
D Knurled Nut, Black
E Knurled Nut, Black w/Locking Ring
F Panel Dress, Bright Nickel
G Panel Dress, Bright Nickel w/Locking Ring
H Panel Dress, Black
J Panel Dress, Black w/Locking Ring
Push Button
1 No outer Panel Hardware
2 Knurled Nut, Bright Nickel
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate
B ON - OFF Vertical
C ON - OFF Horizontal
Push-Pull Actuator Legend Plate
2 Rated Amps Horizontal
3 Rated Amps Line Side Down
4 Rated Amps Line Side Up
2 ACTUATOR
M Paddle
T Push-Pull
8 ACTUATOR COLOR & LEGEND
Handle Push Button
1 White A White
2 Black B Black
3 Red C Red
4 Green D Green
5 Blue E Blue
6 Yellow F Yellow
7 Gray G Gray
8 Orange H Orange
Notes:
1 Aux Switch only available with screw terminals
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Actuator
Color
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M M P 15 B2 B TB
D2 650
9
Front
Panel
Hardware
10
Legend
Plate/
Marking
11
Brushing
Color
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 7 M-Series Parallel Pole - Form & Fit Drawings
1.304[33.12]
1.125[28.58]
.970[24.64]
1.375[34.93]
1.125[28.58]
1.560[39.62]
.370[9.40]MAX.
INDICATE"OFF"(VISI-OFF)
&SINGLE COLOR
ON
OFF
.400[10.16]
ON
OFF
±.020±.508
1.050[26.67]
ON
PANEL CUT - OUT DETAIL (ROCKER)
.125[3.18]
PANEL
THICKNESS
.093[2.36]
.062[1.57]
OFF
1.139[33.76]
DOUBLEPOLE
DIM. A
±.005±.13
LINE
DIM. A
1.460[37.08]
+.005 +.13
-.000 -.00
1.420[36.07]
1.385[35.18]
ROCKERGUARDCONFIGURATION
.675[17.14]
.100[2.54]
LOAD
±.020±.508.305[7.75]
±.020±.508
PUSH-IN STUD
1.000[25.4]
.750[19.05]
.100[2.54]
1.394[35.41]
.393[9.97]
1.000[25.4]
.154[3.91]
ROCKERACTUATOR DETAIL
1.530[38.86]
INDICATE"ON" (VISI-ON)
±.020[±.508]±.020[±.508]
.652[16.56]
.838[21.29]
PARALLEL POLE TERMINALOPTIONS
.912[23.16]
10-32 SCREW W/ BUS BAR
MSERIESPARALLEL POLE
FORM&FIT DIAGRAMS
NOTES:
1. ALLDIMENSIONSARE IN INCHES[MILLIMETERS].
2. TOLERANCE±.010[.25]UNLESSOTHERWISESPECIFIED.
3. DIMENSIONSAPPLY TO BOTH ROCKERSTYLES.
4. I-O,ON-OFF OR DUALLEGENDSAVAILABLE FOR
VERTICAL OR HORIZONTALMOUNTING.
5. NOTICE THATCIRCUITBREAKERLINEANDLOADTERMINAL
ORIENTATION ON INDICATE"OFF"ISOPPOSITETHAT OF
INDICATE"ON".
ME
5/10/12
LINE
DR BY
TITLE
.625[15.88]
LOAD
LOAD
DWG NO
SHT OF
CLA-8121
APVD BY
1 3
REV
A
LINE
REVISIONS
RELEASEDPER
ECO16976
LET
A
DATE
5-10-12
Notes:
1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED.
3 DIMENSIONS APPLY TO BOTH ROCKER STYLES.
4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING.
5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
8 |M-Series Parallel Pole - Form & Fit Drawings
.105[2.67]
.125[3.18]
HEXNUT
.625[15.88]
KNURLED NUT
.683 DIA [Ø17.27]
PANELDRESSNUT
LEGEND PLATES
.680 DIA [Ø17.27]
.632 DIA [Ø16.05]
.680 DIA [Ø17.27]
.180[4.57]
.340[8.64]
B
0N
0FF
.025[.64]
LEGEND
CODE:
PANEL HARDWARE
1.025[26.04]O
N
C
O
F
F
.125[3.18]
.470[11.94]
FLAT
.500[12.70]
.222[5.64]
.500 DIA [Ø12.70]
WITHOUTLOCKINGRING
±.002[±.050]
.125 DIA [Ø3.18]
.500 DIA [Ø12.70]
WITHLOCKINGRING
.355[9.02]
±.005[±.13]
+.010
-.000
+.25
-.000
+.010
-.000
MOUNTING DETAILS
+.25
-.000
±.030±.76
+.25
-.000
+.010
-.000
PADDLE ACTUATOR STYLE
1.395
12°
1/2-32THD.
12°
ON
OFF
MSERIESPARALLEL POLE
FORM&FIT DIAGRAMS
NOTES:
1. ALLDIMENSIONSARE IN INCHES[MILLIMETERS].
2. TOLERANCE±.010[.25]UNLESSOTHERWISESPECIFIED.
3. DIMENSIONSAPPLY TO BOTH ROCKERSTYLES.
4. I-O,ON-OFF OR DUALLEGENDSAVAILABLE FOR
VERTICAL OR HORIZONTALMOUNTING.
5. NOTICE THATCIRCUITBREAKERLINEANDLOADTERMINAL
ORIENTATION ON INDICATE"OFF"ISOPPOSITETHAT OF
INDICATE"ON".
ME
5/10/12
.031[.79]
LOCKINGRING
DR BY
TITLE
.342[8.69]
2 3
APVD BY DWG NO
SHT OF
CLA-8121
REV
A
REVISIONS
RELEASEDPER
ECO16976
LET
A
DATE
5-10-12
.435[11.05]DIA
PANELDRESSNUT
PANEL HARDWARE
HEX NUT
.156
[3.56]
.534
[13.56]
20 20
2
LINE
MARKING
CODE:
20
BUTTON MARKING ORIENTATION
.110QC AUXILIARY SWITCH TERMINALS
LINE
3 4
LINE
SNAP-INBUSHING
.162[4.11]
.625[15.87]DIA
MOUNTING DETAILS
.500[12.70]OFF(SHOWN).400[10.16]
±.002±.05
.280[7.11] ON
±.030±.76
PUSH-PULL,
PUSH TO RESET
.375[9.53]
DIA
.544[13.82]
.494
[12.55]
±.030±.76
PUSH-PULL ACTUATOR STYLE
±.030±.76
FLAT
1.484
3/8"8-32THD.
ACTUATORCOLOR
VISIBLE IN OFF
POSITIONONLY
NOTES:
1. ALLDIMENSIONSARE IN INCHES[MILLIMETERS].
2. TOLERANCE±.010[.25]UNLESSOTHERWISESPECIFIED.
3. DIMENSIONSAPPLY TO BOTH ROCKERSTYLES.
4. I-O,ON-OFF OR DUALLEGENDSAVAILABLE FOR
VERTICAL OR HORIZONTALMOUNTING.
5. NOTICE THATCIRCUITBREAKERLINEANDLOADTERMINAL
ORIENTATION ON INDICATE"OFF"ISOPPOSITETHAT OF
INDICATE"ON".
ME
5/10/12
DR BY
TITLE
3 3
MSERIESPARALLEL POLE
FORM&FIT DIAGRAMS
APVD BY DWG NO
SHT OF
CLA-8121
REV
A
.098
[2.49]
.078
[1.98]
REVISIONS
RELEASEDPER
ECO16976
LET
A
DATE
5-10-12
+.010
-.000
+.25
-.00
Notes:
1 ALL DIMENSIONS ARE IN INCHES [MILLIMETERS].
2 TOLERANCE ±.010 [.25] UNLESS OTHERWISE SPECIFIED.
3 DIMENSIONS APPLY TO BOTH ROCKER STYLES.
4 I-O, ON-OFF OR DUAL LEGENDS AVAILABLE FOR VERTICAL OR HORIZONTAL MOUNTING.
5 NOTICE THAT CIRCUIT BREAKER LINE AND LOAD TERMINAL ORIENTATION ON INDICATE “OFF” IS OPPOSITE THAT OF INDICATE “ON”.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 9 M-Series Handle/Pushbutton UL Recognized - Ordering Scheme
6 CURRENT RATING (AMPERES)8
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
CODE AMPERES
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Actuator
Color
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M M B 11 B1 B BC34 260
1 SERIES
M
7 TERMINAL8
1 Push-On 0.250 Tab (Q.C.)
210 Screw 8-32 w/upturned lugs
310 Screw 8-32 (Bus Type)
A11 Push-In Stud
P12 Printed Circuit Board
3 POLES
1 One 2 Two
4 CIRCUIT2
without Auxiliary Switch
A Switch Only (no coil) , Maintained Contacts
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
P3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Q3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
R3,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
S3 Series Trip (Current) .060 Dia, Round Solder Turret
T3,4 Series Trip (Current) .058 Dia, Round Q.C.
U3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
23,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
33,13 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
43,4 Series Trip (Current) .058 Dia, Round Q.C.
53,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
5 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
12 DC Short
14 DC Medium
20 50/60Hz Instantaneous
22 50/60Hz Short
24 50/60Hz Medium
30 DC, 50/60Hz Instantaneous
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
92 DC, 50/60Hz Short, Hi-Inrush
94 DC, 50/60Hz Medium,
Hi-Inrush
9
Front Panel
Hardware
10
Legend
Plate
11
Bushing
Color
9 FRONT PANEL HARDWARE6
Handle Push-Button
No outer Panel Hardware A 1
Knurled Nut
Bright nickel B 2
Bright nickel with locking ring C
Black D
Black with locking ring E
Panel Dress Nut
Bright nickel F
Bright nickel with locking ring G
Black H
Black with locking ring J
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A No Legend Plate
B ON - OFF Vertical
C ON - OFF Horizontal
D I - O Vertical
E I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
1 No Marking
2 Rated Amps Horizontal
3 Rated Amps Line Side Down
4 Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U& W)
1 No Marking
2 ACTUATOR1
Handle
M Paddle
Push Button
T Push-Pull
Push Button w/ Snap-In Mounting
V Push-Pull
N Baton
U Push To Reset
W Push To Reset
Notes:
1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited
to single pole breakers only.
2 Switch Only circuits are not available with Push-To-Reset actuators. For Switch Only circuits,
select Current Coil Rating from the above chart:
3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch
mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits.
Not available with back connect screw or push-in stud terminals.
4 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated)
and 60983-2 (tin plated).
5 Actuator color is only visible in the OFF position on Push-Pull actuators.
6 All units except snap-in mounting have one hex nut installed on bushing for use behind
the panel.
7 Other colors available. Consult factory.
8 TUV and VDE Certication above 15 amps is for 2-pole only and is limited to a max. of
20 amps. Screw Terminal or Push-In Stud recommended above 20 amps.
9 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
10 Screw Terminals are VDE certied only with use of ring terminal attached to wire.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
12 AGENCY APPROVAL9
C UL Recognized & CSA Accepted
D VDE Certied, UL Recognized & CSA Accepted
E TUV Certied, UL Recognized & CSA Accepted
11 BUSHING COLOR7
B Black
8 ACTUATOR COLOR & LEGEND5
Gloss Handle Push-Button Actuator Color
1 A White
2 B Black
3 C Red
4 D Green
5 E Blue
6 F Yellow
8 H Orange
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
10 |M-Series Handle/Pushbutton UL489A/UL Recognized – Ordering Scheme
1
Series
2
Actuator
3
Poles
6
Current
Rating
7
Terminal
8
Actuator
Color
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M M B 11 B1 B JB14 620
1 SERIES
M
7 TERMINAL4
1 Push-On 0.250 Tab (Q.C.)
2 Screw 8-32 w/upturned lugs
3 Screw 8-32 (Bus Type)
A10 Push-In Stud
P11 Printed Circuit Board
3 POLES
1 One
4 CIRCUIT
without Auxiliary Switch
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
S2 Series Trip (Current) .060 Dia, Round Solder Turret
T2,3 Series Trip (Current) .058 Dia, Round Q.C.
U3,12 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
42,3 Series Trip (Current) .058 Dia, Round Q.C.
53,12 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
5 FREQUENCY & DELAY
10 DC Instantaneous
12 DC Short
14 DC Medium
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
12 AGENCY APPROVAL9
J UL489A Listed, TUV Certied
M UL Recognized, CSA Accepted
N UL Recognized, TUV Certied
T UL489A Listed
11 BUSHING COLOR7
B Black
9
Front Panel
Hardware
10
Legend
Plate
11
Bushing
Color
8 ACTUATOR COLOR & LEGEND5
Gloss Handle Push-Button Actuator Color
1 A White
2 B Black
3 C Red
4 D Green
5 E Blue
6 F Yellow
8 H Orange
10 LEGEND PLATE / BUTTON MARKING
Handle Actuator Legend Plate (Actuator Styles M & N)
A No Legend Plate
B ON - OFF Vertical
C ON - OFF Horizontal
D I - O Vertical
E I - O Horizontal
Push-Pull Actuator Button Cap (Actuator Styles T & V)
18 No Marking
2 Rated Amps Horizontal
3 Rated Amps Line Side Down
4 Rated Amps Line Side Up
Push-to-Reset Actuator Button (Actuator Styles U& W)
18 No Marking
2 ACTUATOR1
Handle
M Paddle
Push Button
T Push-Pull
Push Button w/ Snap-In Mounting
V Push-Pull
N Baton
U8 Push To Reset
W8 Push To Reset
Notes:
1 One actuator is located in the center of each multi-pole breaker. Actuator codes V & W limited
to single pole breakers only.
2 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary Switch
mounting is in pole one. Auxiliary Switch option limited to Series Trip and Switch Only circuits.
Not available with Back Connected Screw or Push-in Stud terminals.
3 Mates with AMP .058” diameter pin receptacles including 60983-1 (gold plated) and
60983-3 (tin plated).
4 Screw terminals or Push-in Stud recommended above 20 amps.
5 Actuator color is only visible in the OFF position on Push-Pull actuators.
6 All units have one hex nut installed on bushing for use behind the panel.
7 Other colors available. Consult factory.
8 Not available with UL489A Listed breakers.
9 TUV certied to 25 amps. UL Recognized, CSA Accepted and UL Listed to 30 amps.
10 Terminal code A available with circuit codes A & B only.
11 Printed circuit board available with UL recognized approval only.
12 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
6 CURRENT RATING (AMPERES)
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
CODE AMPERES
9 FRONT PANEL HARDWARE6
Handle Push-Button
No outer Panel Hardware A 1
Knurled Nut
Bright nickel B 2
Bright nickel with locking ring C
Black D
Black with locking ring E
Panel Dress Nut
Bright nickel F
Bright nickel with locking ring G
Black H
Black with locking ring J
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 11 M-Series Handle – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
12 |M-Series Handle – PC Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 13 M-Series Handle - Form & Fit Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
14 |M-Series Pushbutton – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 15 M-Series Pushbutton – Form & Fit Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ± 0.20 [.51] unless otherwise specied.
3 Available with Push-Pull or Push-to-Reset Actuators
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
16 |M-Series Push-Pull – PC Terminal Drawings
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 17 M-Series Rocker UL Recognized – Ordering Scheme
1
Series
2
Actuator
3
Poles
6
Current Rating
7
Terminal
8
Illumination
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M G B H1 62 C C734 620
1 SERIES
M
3 POLES
1 One 2 Two
4 CIRCUIT2
without Auxiliary Switch
A Switch Only (no coil) , Maintained Contacts
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
P3 Switch Only, Maintained Contacts .060 Dia, Round Solder Turret
Q3,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
R3,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
S3 Series Trip (Current) .060 Dia, Round Solder Turret
T3,4 Series Trip (Current) .058 Dia, Round Q.C.
U3,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
23,4 Switch Only, Maintained Contacts .058 Dia, Round Q.C.
33,16 Switch Only, Maintained Contacts .080 Dia x .020 Flat Q.C.
43,4 Series Trip (Current) .058 Dia, Round Q.C.
53,16 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
5 FREQUENCY & DELAY
03 DC 50/60Hz, Switch Only
10 DC Instantaneous
12 DC Short
14 DC Medium
20 50/60Hz Instantaneous
22 50/60Hz Short
24 50/60Hz Medium
30 DC, 50/60Hz Instantaneous
32 DC, 50/60Hz Short
34 DC, 50/60Hz Medium
62 50/60Hz Short, Hi-Inrush
64 50/60Hz Medium, Hi-Inrush
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
92 DC, 50/60Hz Short, Hi-Inrush
94 DC, 50/60Hz Medium,
Hi-Inrush
11 BEZEL COLOR / STYLE9
Color without Rockerguard with Rockerguard
White A 1
Black B 2
Gray G 7
9
Actuator
Color
10
Legend
11
Bezel Color
8 ROCKER ILLUMINATION
Non-illuminated A
Neon5 Neon Green Glow8
without resistor, 120VAC/250VAC B C
LED7, 8 Red Green Amber
without resistor D G K
with resistor, 4-8 VDC E H L
with resistor, 9-16 VDC F J M
9 ACTUATOR & LEGEND COLOR
Solid Color Actuator Legend
1 White Black
2 Black White
3 Red White
4 Green White
5 Blue White
6 Yellow Black
7 Gray Black
8 Orange Black
Visi-Rocker6 Visi & Legend (remainder of rocker same color as bezel)
1 White
2 Black
3 Red
4 Green
5 Blue
6 Yellow
7 Gray
8 Orange
Illuminated8 Actuator Legend
A Clear White
B Red Transparent White
C Green Transparent White
D Amber Transparent White
E Smoke Gray Transparent White
F White Translucent Black
10 LEGEND11
1 No Legend
2 ON - OFF Vertical
3 ON - OFF Horizontal
4 I - O Vertical
5 I - O Horizontal
6 Dual Vertical
7 Dual Horizontal
2 ACTUATOR1
Notes:
1 One actuator is located in the center of each multi-pole breaker.
2 For Switch Only circuits, select Current Coil Rating from the above chart:
3 One Auxiliary Switch is supplied per breaker. On two-pole breakers, standard Auxiliary
Switch mounting is in pole one. Auxiliary Switch option limited to Series Trip & Switch Only
circuits, & is not available in single pole illuminated breakers, or Back Connected Screw or
Push-in Stud terminals.
4 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-2
(tin plated).
5 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7 For LED (DC or rectied AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics: 100 millicandela at 20mA; Maximum power
dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward voltage
= 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the proper
external resistor limiting current to these values.
8 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or
match color of LED or neon lamp.
9 Other colors available. Consult factory.
10 TUV 20A, VDE 15A. UL Recognized and CSA Accepted to 30 amps.
Screw Terminals or Push-in Stud recommended above 20 amps.
11 TUV or VDE Certied must have I-O or Dual Legends. Legend required on Visi-Rocker
breakers.
12 30 amp rating not available with delay’s 30, 32, 34, 92 or 94.
13 Screw Terminals are VDE certied only with use of ring terminal attached to wire.
14 Terminal code A available with circuit codes A & B only.
15 Printed circuit board available with UL recognized approval only.
16 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
Non-Illuminated
single color
A Angled
B Flat
Two Color
Visi-Rocker
D Indicate ON
E Indicate OFF
illuminated
single color
F Angled
G Flat
6 CURRENT RATING (AMPERES)
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
63012 30.000
CODE AMPERES
7 TERMINAL
1 Push-On 0.250 Tab (Q.C.)
210 Screw 8-32 w/upturned lugs
310 Screw 8-32 (Bus Type)
A14 Push-In Stud
P15 Printed Circuit Board
12 AGENCY APPROVAL10
C UL Recognized & CSA Accepted
D VDE Certied, UL Recognized & CSA Accepted
E TUV Certied, UL Recognized & CSA Accepted
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
18 |M-Series Rocker UL489A/UL Recognized – Ordering Scheme
11 BEZEL COLOR / STYLE8
Color without Rockerguard with Rockerguard
White A 1
Black B 2
Gray G 7
9 ACTUATOR & LEGEND COLOR
Solid Color Actuator Legend
1 White Black
2 Black White
3 Red White
4 Green White
5 Blue White
6 Yellow Black
7 Gray Black
8 Orange Black
Visi-Rocker6 Visi & Legend (remainder of rocker same color as bezel)
1 White
2 Black
3 Red
4 Green
5 Blue
6 Yellow
7 Gray
8 Orange
Illuminated7 Actuator Legend
A Clear White
B Red Transparent White
C Green Transparent White
D Amber Transparent White
E Smoke Gray Transparent White
F White Translucent Black
1
Series
2
Actuator
3
Poles
6
Current Rating
7
Terminal
8
Illumination
12
Agency
Approval
4
Circuit
5
Frequency
& Delay
M A B A1 61 1 J214 620
1 SERIES
M
3 POLES
1 One
4 CIRCUIT2
without Auxiliary Switch
B Series Trip (Current)
with Auxiliary Switch, Silver Contacts Terminal Type:
M Series Trip (Current) Aux Switch .110 QC x .020 QC
S Series Trip (Current) .060 Dia, Round Solder Turret
T3 Series Trip (Current) .058 Dia, Round Q.C.
U3,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
with Auxiliary Switch, Gold Contacts
43 Series Trip (Current) .058 Dia, Round Q.C.
53,13 Series Trip, Maintained Contacts .080 Dia x .020 Flat Q.C.
9 Series Trip (Current) Aux Switch .110 QC x .020 QC
5 FREQUENCY & DELAY
10 DC Instantaneous
12 DC Short
14 DC Medium
72 DC, Short,Hi-Inrush
74 DC,Medium, Hi-Inrush
9
Actuator
Color
10
Legend
11
Bezel Color
10 LEGEND10
1 No Legend (Single Color or Illuminated Rocker Options Only)
2 ON - OFF Vertical
3 ON - OFF Horizontal
4 I - O Vertical
5 I - O Horizontal
6 Dual Vertical
7 Dual Horizontal
2 ACTUATOR1
Notes:
1 One actuator is located in the center of each multi-pole breaker.
2 One Auxiliary Switch is supplied per breaker. Auxiliary Switch option limited to Series Trip
& Switch Only circuits, and is not available in single pole illuminated breakers, or with Back
Connected Screw or Push-in Stud terminals.
3 Mates with AMP .058” diameter pin receptacles: 60983-1 (gold plated) & 60983-1
(tin plated).
4 For neon bulb applications at 120VAC @ 47K, 1/4 WATT and for 250VAC applications @
150K, 1/4 WATT, external resistors must be supplied by customer.
5 For LED (DC or rectied AC) applications, LED is mounted in the center of the rocker
actuator with electrical characteristics as follows: 100 millicandela at 20mA; Maximum
power dissipation = 75mW at 25°C; Maximum forward current = 25mA; Typical forward
voltage = 2.1V at 20mA; Typical reverse current = 100uA at 3V. Customer supplies the
proper external resistor limiting current to these values.
6 On Visi-Rocker breakers, Visi portion of rocker cannot be the same color as the bezel.
7 Rocker color for LED’s and green neon lamp must be clear, smoke gray, white translucent or
match color of LED or neon lamp.
8 Other colors available. Consult factory.
9 TUV Certied to 25 amps. UL Recognized, CSA Accepted and UL489A Listed to 30 amps.
Screw Terminals recommended above 20 amps.
10 UL489A Listed must have ON-OFF or Dual legends. TUV Certied approvals must have
I - O or Dual legends.
11 Terminal code A available with circuit codes A & B only.
12 Printed circuit board available with UL recognized approval only.
13 Auxiliary switch (at Q.C.) available with UL recognized approvals only.
Non-Illuminated
single color
A Angled
B Flat
Two Color
Visi-Rocker
D Indicate ON
E Indicate OFF
llluminated
single color
F Angled
G Flat
6 CURRENT RATING (AMPERES)8
020 0.020
025 0.025
030 0.030
035 0.035
040 0.040
045 0.045
050 0.050
055 0.055
060 0.060
065 0.065
070 0.070
075 0.075
080 0.080
085 0.085
090 0.090
090 0.095
210 0.100
215 0.150
220 0.200
225 0.250
230 0.300
235 0.350
240 0.400
245 0.450
250 0.500
255 0.550
260 0.600
265 0.650
270 0.700
275 0.750
280 0.800
285 0.850
290 0.900
295 0.950
410 1.000
512 1.250
415 1.500
517 1.750
420 2.000
522 2.250
425 2.500
527 2.750
430 3.000
435 3.500
440 4.000
445 4.500
450 5.000
455 5.500
460 6.000
465 6.500
470 7.000
475 7.500
480 8.000
485 8.500
490 9.000
495 9.500
610 10.000
710 10.500
611 11.000
711 11.500
612 12.000
712 12.500
613 13.000
614 14.000
615 15.000
616 16.000
617 17.000
618 18.000
620 20.000
622 22.000
624 24.000
625 25.000
630 30.000
CODE AMPERES
7 TERMINAL9
1 Push-On 0.250 Tab (Q.C.)
2 Screw 8-32 w/upturned lugs
3 Screw 8-32 (Bus Type)
A11 Push-In Stud
P12 Printed Circuit Board
12 AGENCY APPROVAL9
J UL489A Listed & TUV Certied
M UL Recognized & CSA Accepted
N TUV Certied, UL Recognized & CSA Accepted
T UL489A Listed
8 ILLUMINATION
Non-illuminated A
Neon4 Neon Green Glow8
without resistor, 120VAC/250VAC B C
LED7, 8 Red Green Amber
without resistor D G K
with resistor, 4-8 VDC E H L
with resistor, 9-16 VDC F J M
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 19 M-Series Rocker – Circuit & Terminal Diagrams
Notes:
1 All dimensions are in inches [millimeters].
2 Tolerance ±.020 [.51] unless otherwise specied.
3 Schematic shown represents current trip circuit.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
20 |M-Series Rocker – Form & Fit Drawings
Notes:
1 Dimensions apply to all variations shown. Notice that circuit breaker line & load terminal orientation on indicate OFF is opposite of indicate ON.
2 I-O, ON-OFF or dual legends available for vertical or horizontal mounting. For pole orientation with horizontal legend, rotate front view clockwise 90°.
3 All dimensions are in inches [millimeters].
4 Tolerance ± 0.20 [.51] unless otherwise specied.
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 21 M-Series Rocker – Supplementary Diagrams
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
22 |M-Series Circuit Breaker - Time Delay Curve
Notes:
1 Delay Curves 12,14, 22, 24, 32, 34, 62, 64, 72, 74, 92, 94: Breakers to hold 100% and must trip at 135% of rated current and greater within the time limit shown in this curve.
2 Delay Curves 10, 20, 30: Breakers to hold 100% and must trip at 150% of rated current and greater within the time limit shown in this curve.
3 All Curves: Curve data shown represents breaker response at ambient temperature of 77°F (25°C) with no preloading. Breakers are mounted in standard wall-mount position.
4 The minimum inrush pulse tolerance handling capability is 12 times the rated current on standard delays and 18 times the rated current on high inrush delays. These values are based on a 60 Hz 1/2 cycle,
8.33 ms pulse. High inrush delays should be specied for applications with high initial surge currents of short duration, such as switching power supplies, highly capacitive loads and transformer loads.
Medium Medium D4
Instantaneous
Short Short D2
Dual Rated AC/DC
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
60 Johnson Avenue • Plainville, CT 06062 • Phone: (860) 793–9281 • Fax: (860) 793–9231
Email: sales@carlingtech.com • www.carlingtech.com
| 23 Notes
* Intentionally left blank
Worldwide Headquarters
Carling Technologies, Inc.
60 Johnson Avenue • Plainville, CT 06062
Phone: (860) 793-9281 • Fax: (860) 793-9231
Email: sales@carlingtech.com • www.carlingtech.com
East Region Sales Oce, CT • ersm@carlingtech.com
Midwest Region Sales Oce, IL • mrsm@carlingtech.com
West Region Sales Oce, CA • wrsm@carlingtech.com
Asia-Pacic Headquarters
Carling Technologies, Asia-Pacic Ltd.,
Kowloon, Hong Kong
Int + 852-2737-2277 • Fax: Int + 852-2736-9332
Email: sales@carlingtech.com.hk
Shenzhen, China • shenzhen@carlingtech.com
Shanghai, China • shanghai@carlingtech.com
Pune, India • india@carlingtech.com
Kaohsiung, Taiwan • taiwan@carlingtech.com
Yokohama, Japan • japan@carlingtech.com
Europe/Middle East/Africa Headquarters
Carling Technologies LTD
4 Airport Business Park, Exeter Airport,
Clyst Honiton, Exeter, Devon, EX5 2UL, UK
Int + 44 1392-364422 • Fax: Int + 44 1392-364477
Email: ltd.sales@carlingtech.com
GmbH, Germany • gmbh@carlingtech.com
SAS, France • sas@carlingtech.com
REV_CB_M_07_2014