SPT 5/ 6-V-7,5-ZB
Order No.: 1719354
The figure shows a 5-pos. version of the product
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1719354
PC terminal block, Nominal current: 41 A, Nom. voltage: 800 V, Pitch:
7.5 mm, Number of positions: 6, Type of connection: Spring-cage
conn., Assembly: Soldering, Conductor/PCB connection direction: 90
°, Color: green
Commercial data
EAN 4046356141451
Pack 50 pcs.
Customs tariff 85369010
Weight/Piece 0.02298 KG
Catalog page information Page 337 (CC-2009)
Product notes
WEEE/RoHS-compliant since:
06/21/2007
http://
www.download.phoenixcontact.com
Please note that the data given
here has been taken from the
online catalog. For comprehensive
information and data, please refer
to the user documentation. The
General Terms and Conditions of
Use apply to Internet downloads.
Technical data
Dimensions / positions
Pitch 7.5 mm
Dimension a 37.5 mm
Number of positions 6
SPT 5/ 6-V-7,5-ZB Order No.: 1719354
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1719354
PHOENIX CONTACT Inc., USA Page 2 / 5
http://www.phoenixcon.com Feb 17, 2010
Pin dimensions 1,7 x 0,8
Pin spacing 7.5 mm
Hole diameter 2.1 mm
Technical data
Insulating material group I
Rated surge voltage (III/3) 8 kV
Rated surge voltage (III/2) 8 kV
Rated surge voltage (II/2) 6 kV
Rated voltage (III/2) 1000 V
Rated voltage (II/2) 1000 V
Connection in acc. with standard EN-VDE
Nominal current IN41 A
Nominal voltage UN800 V
Nominal cross section 6 mm²
Maximum load current 41 A
Insulating material PA
Inflammability class acc. to UL 94 V0
Stripping length 15 mm
Connection data
Conductor cross section solid min. 0.2 mm²
Conductor cross section solid max. 10 mm²
Conductor cross section stranded min. 0.2 mm²
Conductor cross section stranded max. 6 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
without plastic sleeve max.
6 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve min.
0.25 mm²
Conductor cross section stranded, with ferrule
with plastic sleeve max.
4 mm²
Conductor cross section AWG/kcmil min. 24
Conductor cross section AWG/kcmil max 8
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, min.
0.25 mm²
2 conductors with same cross section, stranded,
TWIN ferrules with plastic sleeve, max.
1.5 mm²
SPT 5/ 6-V-7,5-ZB Order No.: 1719354
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1719354
PHOENIX CONTACT Inc., USA Page 3 / 5
http://www.phoenixcon.com Feb 17, 2010
Certificates / Approvals
Certification CB, CCA, CUL, SEV, UL
CUL
Nominal voltage UN600 V
Nominal current IN35 A
AWG/kcmil 24-8
UL
Nominal voltage UN600 V
Nominal current IN35 A
AWG/kcmil 24-8
Diagrams/Drawings
Drilling plan/solder pad geometry
SPT 5/ 6-V-7,5-ZB Order No.: 1719354
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1719354
PHOENIX CONTACT Inc., USA Page 4 / 5
http://www.phoenixcon.com Feb 17, 2010
Diagram
Type: SPT 5/...-V-7,5-ZB
Test based on DIN EN 60512-5-2:2003-01
Reduction factor = 1
Dimensioned drawing
SPT 5/ 6-V-7,5-ZB Order No.: 1719354
http://eshop.phoenixcontact.de/phoenix/treeViewClick.do?UID=1719354
PHOENIX CONTACT Inc., USA Page 5 / 5
http://www.phoenixcon.com Feb 17, 2010
Address
PHOENIX CONTACT Inc., USA
586 Fulling Mill Road
Middletown, PA 17057,USA
Phone (800) 888-7388
Fax (717) 944-1625
http://www.phoenixcon.com
© 2010 Phoenix Contact
Technical modifications reserved;