SPECIFICATION
120W AC-DC Reliable Green Industrial Adaptor GST120A ser ie s
ORDER NO.
DC VOLTAGE
SAFETY MODEL NO.
RATED CURRENT
CURRENT RANGE
RATED POWER (max.)
RIPPLE & NOISE (max.) Note.2
OUTPUT
VOLTAGE RANGE Note.6
FREQUENCY RANGE
POWER FACTOR (Typ.)
EFFICIENCY (Typ.)
AC CURRENT
INPUT
ENVIRONMENT
INRUSH CURRENT (max.)
LEAKAGE CURRENT(max.)
SAFETY STANDARDS Note. 7
SAFETY &
EMC
(Note. 8)
WORKING TEMP.
WORKING HUMIDITY
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSION
OTHERS
NOTE
PACKING
PROTECTION
GST120A15
GST120A15-R7B
GST120A12
GST120A12-R7B
GST120A20
GST120A20-□
□=R7B,P1M □=R7B,P1M □=R7B,P1M
GST120A24
GST120A24-□
GST120A48
GST120A48-□
15V12V 20V 24V 48V
120mVp-p120mVp-p 150mVp-p 180mVp-p 200mVp-p
VOLTAGE TOLERANCE Note.3
LINE REGULATION Note.4
LOAD REGULATION
±5.0% ±3.0% ±2.5%
±1.0% ±1.0% ±1.0%
±5.0% ±3.0% ±2.5%
85 ~ 264VAC 120 ~ 370VDC
47 ~ 63Hz
PF>0.93 / 230VAC PF>0.97 / 115VAC at full load
89%
-----
88.5%
-----
90%
89%
90.5%
89.5%
91%
90.5%
1.4A / 115VAC 0.7A / 230VAC
Cold start 35 / 115AC 70A / 230VAC
0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P: 3KVAC
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
368.75K hrs min. MIL-HDBK-217F(25℃)
-30 ~ +70℃ (Refer to "Derating Curve")
20% ~ 90% RH non-condensing
-40 ~ +85℃, 10 ~ 95% RH non-condensing
±0.03% / ℃ (0~45℃)
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
167*67*35mm (L*W*H)
0.62Kg; 20pcs/13.4Kg/0.89CUFT
CONNECTOR
PLUG
CABLE See page 4~5 ; Other type available by customer requested
See page 4~5 ; Other type available by customer requested
℃
For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”
(as available on http://www.meanwell.com)
https://www.meanwell.com/serviceDisclaimer.aspx※:
OVERLOAD
OVER VOLTAGE
105 ~ 160% rated output power
Protection type : Hiccup mode, recovers automatically after fault condition is removed
105 ~ 135% rated output voltage
7A8.5A 6A 5A 2.5A
0 ~ 7A0 ~ 8.5A 0 ~ 6A 0 ~ 5A
0 ~ 2.5A
105W102W 120W 120W 120W
Protection type : Shut down o/p voltage, re-power on to recover
SETUP, RISE TIME Note.5
HOLD UP TIME (Typ.)
2000ms, 30ms / 230VAC 2500ms, 30ms / 115VAC at full load
20ms / 230VAC 20ms / 115VAC at full load
OVER TEMPERATURE Shut down o/p voltage, re-power on to recover
±5.0%
±1.0%
±5.0%
±5.0%
±1.0%
±4.0%
R7B
P1M
UL62368-1, CSA C22.2 No. 62368-1, TUV EN62368-1, BSMI CNS14336, CCC GB4943.1, PSE J62368-1,AS/NZS 60950.1 ,
BIS IS13252, KC K60950-1, approved EAC TP TC 004 approved; SIRIM MS IEC60950-1 (optional)
EMC IMMUNITY
EMC EMISSION
Parameter Standard
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
EN61000-3-2,GB9254
Test Level / Note
Class B
-------
EN61000-3-3
Class B
Class A
Parameter
ESD
Standard
EN61000-4-2
Test Level /Note
EN61000-4-3
EN61000-4-4
EN61000-4-6
EN61000-4-5
EN61000-4-8
EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods,
>95% interruptions 250 periods
EN55032(CISPR32),FCC PART 15 / CISPR22
CAN ICES-3(B)/NMB-3(B),CNS13438,GB17625.1
EAC TP TC 020,MSIP KN32
μ
μ
Conducted emission
Radiated emission
Harmonic current
Voltage flicker
RF field susceptibility
EFT bursts
Surge susceptibility
Level 4, 15KV air; Level 4, 8KV contact
Conducted susceptibility
Magnetic field immunity
Voltage dips , interruption
Level 2, 3V/m
Level 3, 1KV/Line-Line , 2KV/Line-FG
Level 2, 3A/m
Level 2, 3V
Level 2, 1KV
File Name:GST120A-SPEC 2020-10-20