E2F E2F
2
Short Length, Shielded Sensors With
Threaded Plastic Body
Rugged, watertight plastic housing offers
good chemical resistance and with-
stands washdown
Wide operating voltages: 10 to 30 VDC
and 20 to 264 VAC
Operation indicator on all models
Short-circuit protection available on all
DC and some A C models
Ordering Information
Plastic Cylindrical Inductive Prox E2F
DC THREE-WIRE PREWIRED MODELS
AC TWO-WIRE PREWIRED MODELS
Ty pe Size Sensing distance Part number
NO NC
Shielded M8 1.5 mm NPN E2F-X1R5E1 E2F-X1R5E2
PNP E2F-X1R5F1 E2F-X1R5F2
M12 2 mm NPN E2F-X2E1 E2F-X2E2
PNP E2F-X2F1 E2F-X2F2
M18 5 mm NPN E2F-X5E1 E2F-X5E2
PNP E2F-X5F1 E2F-X5F2
M30 10 mm NPN E2F-X10E1 E2F-X10E2
PNP E2F-X10F1 E2F-X10F2
Ty pe Size Sensing distance Part number
NO NC
Shielded M8 1.5 mm E2F-X1R5Y1 E2F-X1R5Y2
M12 2 mm E2F-X2Y1 E2F-X2Y2
M18 5 mm E2F-X5Y1-US E2F-X5Y2-US
M30 10 mm E2F-X10Y1-US E2F-X10Y2-US
Without Short-CIrcuit Protection
Ty pe Size Sensing distance Part number
NO NC
Shielded M18 5 mm E2F-X5Y1-53-US E2F-X5Y2-53-US
M30 10 mm E2F-X10Y1-53-US E2F-X10Y2-53-US
With Short-CIrcuit Protection
Output
configuration
E2F E2F
3
Mounting hardware:
one pair of plastic nuts
Description Part number
Mounting brackets Fits M8 size sensors Y92E-B8
Fits M12 size sensors Y92E-B12
Fits M18 size sensors Y92E-B18
Fits M30 size sensors Y92E-B30
ACCESSORIES
Description Part number
Fits M8 size sensors (supplied with each sensor) M8-PHWS
Fits M12 size sensors (supplied with each sensor) M12-PHWS
Fits M18 size sensors (supplied with each sensor) M18-PHWS
Fits M30 size sensors (supplied with each sensor) M30-PHWS
REPLACEMENT PARTS
E2F E2F
4
Specifications
DC 3-WIRE MODELS
Part number E2F-X1R5 E2F-X2 E2F-X5 E2F-X10
Sensor Type Inductive
Body Size M8 M12 M18 M30
Type Shielded
Supply voltage 10 to 30 VDC
Current consumption 17 mA max.
Detectable object type Metallic objects
Effective maximum detecting 1.5 mm (0.06 in) 2 mm (0.08 in) 5 mm (0.20 in) 10 mm (0.39 in)
distance (with standard target) ±15% ±10% ±10% ±10%
Usable detecting range 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
(with standard target) (0 to 0.05 in) (0 to 0.06 in) (0 to 0.16 in) (0 to 0.31 in)
Standard target size 8 x 8 x 1 mm 12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm
(mild steel, L x W x H) (0.31 x 0.31 x 0.04 in) (0.47 x 0.47 x 0.04 in) (0.71 x 0.71 x 0.04 in) (1.18 x 1.18 x 0.04 in)
Differential travel 10% max. of effective max. detecting distance
Type NPN-NO open collector with pull-up (E2F-XE1)
NPN-NC open collector with pull-up (E2F-XE2)
PNP-NO open collector with pull-down (E2F-XF1)
PNP-NC open collector with pull-down (E2F-XF2)
Max. load 200 mA
Max. on-state 2 VDC
voltage drop
Response frequency 2 Hz 1.5 kHz 600 Hz 400 Hz
Ouput short- Provided; automatic resetting type
circuit
DC power Provided
supply reverse
polarity
Weld field Not provided
immunity
RFI immunity Not provided
Indicators Target Present (red LED)
Materials Housing Plastic
Sensing face Plastic
Cable sheath Plastic
Mounting Two plastic M8 nuts Two plastic M12 nuts Two plastic M18 nuts Two plastic M30 nuts
included. Bracket included. Bracket included. Bracket included. Bracket
Y92E-B8 optional. Y92E-B12 optional. Y92E-B18 optional. Y92E-B30 optional.
Connections Prewired 3-conductor cable, 2 m (6.56 ft) length
Weight with cable Approx. 40 g Approx. 50 g Approx. 130 g Approx. 170 g
(1.4 oz) (1.8 oz) (4.6 oz) (6.0 oz)
UL
NEMA ---
IEC 144 IP67
Approvals UL
CSA
Ambient operating temperature -25°C to 70°C (-13° to 158°F)
Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock Approx. 100 G
DC
solid-
state
Control
output
Circuit
protection
Enclosure
ratings
E2F E2F
5
AC 2-WIRE MODELS
Part number E2E2F-X1R5YE2F-X2YE2F-X5Y-US E2F-X10Y-US
E2F-X5Y-53-US E2F-X10Y-53-US
Sensor Type Inductive
Body Size M8 M12 M18 M30
Type Shielded
Supply voltage 20 to 264 VDC, 50/60 Hz 20 to 264 VAC, 50/60 Hz (E2F-XY-US)
90 to 140 VAC, 50/60 Hz (E2F-XY-53-US)
Current consumption 5 mA max.
Detectable object type Metallic objects
Effective maximum detecting 1.5 mm (0.06 in) 2 mm (0.08 in) 5 mm (0.20 in) 10 mm (0.39 in)
distance (with standard target) ±15% ±10% ±10% ±10%
Usable detecting range 0 to 1.2 mm 0 to 1.6 mm 0 to 4 mm 0 to 8 mm
(with standard target) (0 to 0.05 in) (0 to 0.06 in) (0 to 0.16 in) (0 to 0.31 in)
Standard target size 8 x 8 x 1 mm 12 x 12 x 1 mm 18 x 18 x 1 mm 30 x 30 x 1 mm
(mild steel, L x W x H) (0.31 x 0.31 x 0.04 in) (0.47 x 0.47 x 0.04 in) (0.71 x 0.71 x 0.04 in) (1.18 x 1.18 x 0.04 in)
Differential travel 10% max. of effective max. detecting distance
Type SCR-NO (E2F-XY1--)
SCR-NC (E2F-XY2--)
Max. load 100 mA 300 mA for E2F-XY-US and
E2F-XY-53-US at -25°C to 70°C
(-13°F to 158°F)
500 mA for E2F-XY-US at -25°C to 55°C
(-13°F to 131°F)
Min. load 5 mA
Max. off-state 1.7 mA at 200 VAC 1.7 mA at 200 VAC (E2F-XY-US)
leakage current 1.5 mA at 200 VAC (E2F-XY-53-US)
Max. on-state See "Residual Load Voltage Characteristics" graph in
Engineering Data
.
voltage drop
Response frequency 25 Hz
Ouput short- Not provided Provided on E2F-XY-53-US types only;
circuit manual resetting type
Weld field Not provided
immunity
RFI immunity Not provided
Indicators Output Operation (red LED)
Materials Housing Polyarylate
Sensing face Polyarylate
Cable sheath Polyvinal Chloride
Mounting Two plastic M8 nuts Two plastic M12 nuts Two plastic M18 nuts Two plastic M30 nuts
included. Bracket included. Bracket included. Bracket included. Bracket
Y92E-B8 optional. Y92E-B12 optional. Y92E-B18 optional. Y92E-B30 optional.
Connections Prewired 2-conductor cable, 2 m (6.56 ft) length
Weight with cable Approx. 40 g Approx. 50 g Approx. 130 g Approx. 170 g
(1.4 oz) (1.8 oz) (4.6 oz) (6.0 oz)
UL 1
NEMA ---
IEC 144 IP67
Approvals UL Recognized, File number E76675
CSA Certified, FIle number LR45951
Ambient operating temperature -25°C to 70°C (-13° to 158°F)
Vibration 10 to 55 Hz, 1.5 mm (0.06 in) double amplitude
Shock Approx. 100 G
AC
solid-
state
Control
output
Circuit
protection
Enclosure
ratings
E2F E2F
6
OUTPUT CIRCUIT DIAGRAM AND TIMING CHARTS
Operation
DC 3-Wire Models
AC 2-Wire Models With Short-Circuit Protection
E2F E2F
7
Engineering Data
Operating Range
Detecting Distance vs. Size and Material of Target
Shielded M8 and M12 Size Sensors
E2F-X1R5

, E2F-X2


Shielded M18 and M30 Size Sensors
E2F-X5

, E2F-X10


Shielded M8 and M12 Size Sensors
E2F-X1R5

, E2F-X2


Shielded M18 and M30 Size Sensors
E2F-X5

, E2F-X10


Note: If the target is a nonferrous metal, the oper ating distance of the proximity sensor decreases. Ho wev er , with a piece of foil measuring
about 0.01 mm (0.0004 in) in thickness, the detecting distance is equivalent to that with a ferrous metal. Note that the proximity
sensor cannot detect extremely thin evaporated films and non-conductive targets.
E2F E2F
8
Residual Load Voltage Characteristics
Leakage Current Characteristics
E2F E2F
9
AC-2-Wire Models
Dimensions
Unit: mm (inch)
DC 3-Wire Models
SENSORS
E2F E2F
10
AC Shielded M18 Size without
short-circuit protection
E2F-X5Y
-US
AC Shielded M18 Size with
short-circuit protection
E2F-X5Y
-53-US
OPTIONAL MOUNTING BRACKETS
Drawing dimensions
A BCDEF
Y92E-B8 18 ±0.2 10 18 8 28 M4 x 20 E2F-X1R5E(F)(Y)
(0.71 ±0.01) (0.39) (0.71) (0.31) (1.10) bolt
max. dia. max.
Y92E-B12 24 ±0.2 12.5 20 12 37 M4 x 25 E2F-X2E(F)(Y)
(0.94 ±0.01) (0.49) (0.79) (0.47) (1.46) bolt
max. dia. max.
Y92E-B18 32 ±0.2 17 30 18 47 M5 x 32 E2F-X5E(F)(Y)-US,
(1.26 ±0.01) (0.67) (1.18) (0.71) (1.85) bolt E2F-X5Y-53-US
max. dia. max.
Y92E-B30 45 ±0.2 1 7 50 30 60 M 5 x 5 0 E2F-X10E(F)(Y)-US,
(1.77 ±0.01) (0.67) (1.97) (1.18) (2.36) bolt E2F-X10Y-53-US
max. dia. max.
Part
number Applicable sensor
models
E2F E2F
Precautions
TIGHTENING FORCE
Do not exceed the torque listed in the
table provided when tightening the
mounting nuts.
Part number Maximum torque
kg-cm in-lbs
E2F-X1R5 8 6.93
E2F-X2 8 6.93
E2F-X5-(53)-US 20 17.32
E2F-X10-(53)-US 20 17.32
EFFECTS OF SURROUNDING METALS
When mounting a proximity sensor flush with a metallic
panel, be sure to provide a minimum distance as shown
in the table below. This prevents the sensor from being
effected by metallic objects other than the target.
Sensor model
E2F-X1R5 E2F-X2 E2F-X5 E2F-X10
mm inch mm inch mm inch mm inch
l00000000
d (dia.) 8 0.31 12 0.47 18 0.71 30 1.18
D00000000
m 4.5 0.18 8 0.31 20 0.79 40 1.57
Drawing
dimension
MUTUAL INTERFERENCE
To prevent mutual interference between two sensors, be
sure to space the two sensors at a distance greater than
that shown in the table below.
l
m
D
φd
Sensor model
E2F-X1R5 E2F-X2 E2F-X5 E2F-X10
mm inch mm inch mm inch mm inch
A 20 0.79 30 1.18 50 1.97 100 3.94
B150.59200.79351.38702.76
Drawing
dimension
A
B
OMRON ELECTRONICS LLC OMRON CANADA, INC.
One East Commerce Drive 885 Milner Avenue
Schaumburg, IL 60173 Scarborough, Ontario M1B 5V8
1-800-55-OMRON 416-286-6465
Cat. No. CEDSAX4 06/09 Specifications subject to change without notice. Printed in the U.S.A.
OMRON ON-LINE
Global - http://www.omron.com
USA - http://www.omron247.com
Canada - http://www.omron.ca
Mouser Electronics
Authorized Distributor
Click to View Pricing, Inventory, Delivery & Lifecycle Information:
Omron:
E2FM-X5D1-M1TGJ-T 0.3M E2FM-X10D1-M1TGJ 0.3M E2FM-X1R5D1-M1TGJ 0.3M E2FM-X2D1-M1TGJ-T 0.3M
E2FM-X2D1-M1TGJ 0.3M E2FM-X5D1-M1TGJ 0.3M M8-PHWS