SPECIFICATIONS
MODEL PJA600F-5 PJA600F-12 PJA600F-15 PJA600F-24 PJA600F-36 PJA600F-48
INPUT
VOLTAGE[V] AC85 - 264 1f (Output derating is required at AC85V - 100V. See 1.1 and 3.2 in Instruction Manual)
CURRENT[A]
ACIN 100V
6.7typ (Io=100%) 7.5typ (Io=100%)
ACIN 115V
5.7typ (Io=100%) 6.5typ (Io=100%)
ACIN 230V
2.8typ (Io=100%) 3.2typ (Io=100%)
FREQUENCY[Hz] 50 / 60 (47 - 63)
EFFICIENCY[%]
ACIN 100V
76typ (Io=100%) 81typ (Io=100%) 82typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%)
ACIN 115V
77typ (Io=100%) 82typ (Io=100%) 82typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 85typ (Io=100%)
ACIN 230V
79typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%)
POWER FACTOR
ACIN 100V
0.99typ (Io=100%)
ACIN 115V
0.98typ (Io=100%)
ACIN 230V
0.95typ (Io=100%)
INRUSH CURRENT[A]
ACIN 100V
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
ACIN 115V
20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
ACIN 230V
40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start)
LEAKAGE CURRENT[mA] 1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN)
OUTPUT
VOLTAGE[V] 5 12 15 24 36 48
CURRENT[A]
ACIN 85-100V
Output derating is required at ACIN 100V or less (refer to instruction manual 3.2)
ACIN 100V-264V
100 50 40 25 16.7 12.5
WATTAGE[W]
ACIN 85-100V
Output derating is required at ACIN 100V or less (refer to instruction manual 3.2)
ACIN 100V-264V
500 600 600 600 601.2 600
LINE REGULATION[mV]
*
7
20max 48max 60max 96max 144max 192max
LOAD REGULATION[mV]
*
7
40max 100max 120max 150max 150max 300max
RIPPLE[mVp-p]
*1
0 to +50C
80max 120max 120max 120max 150max 150max
-20 to 0C
140max 160max 160max 160max 160max 400max
RIPPLE NOISE[mVp-p]
*1
0 to +50C
120max 150max 150max 150max 200max 200max
-20 to 0C
160max 180max 180max 180max 240max 500max
TEMPERATURE REGULATION[mV]
0 to +50C
50max 120max 150max 240max 360max 480max
-20 to +50C
75max 180max 180max 290max 440max 600max
DRIFT[mV]
*
2
20max 48max 60max 96max 144max 192max
START-UP TIME[ms] 300typ (ACIN 100V, Io=100%)
HOLD-UP TIME[ms] 20typ (ACIN 100V, Io=100%)
OUTPUT VOLTAGE ADJUSTMENT RANGE[V]
4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80
OUTPUT VOLTAGE SETTING[V]
5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92
PROTECTION
CIRCUIT AND
OTHERS
OVERCURRENT PROTECTION
Works over 105% of rating and recovers automatically
OVERVOLTAGE PROTECTION[V]
5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 55.20 to 67.20
OPERATING INDICATION LED (Green)
REMOTE SENSING Optional (Option -W)
REMOTE ON/OFF Optional (Required external power source. Option -R)
ISOLATION
INPUT-OUTPUT RC
*
3
AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature)
OUTPUT RC-FG
*
3
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
OUTPUT-RC
*
3
AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature)
ENVIRONMENT
OPERATING TEMP.,HUMID.AND ALTITUDE
*
4
-20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max
STORAGE TEMP.,HUMID.AND ALTITUDE
-20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max
VIBRATION 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes
IMPACT 196.1m/s2 (20G), 11ms, once each X, Y and Z axes
SAFETY AND
NOISE
REGULATIONS
AGENCY APPROVALS UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN
CONDUCTED NOISE Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B
HARMONIC ATTENUATOR
*
9
Complies with IEC61000-3-2 class A
1 Series name
2 Single output
3 Output wattage
4 Universal input
5 Output voltage
6 Optional
*6
C
: with Coating
G
: Low leakage current
V
:
External potentiometer for
output voltage adjustment
W: Parallel operation,
LV alarm and Remote sensing
R : Remote on/off
(Required external power source)
F4 :
Low speed fan
See 5.1 in Instruction Manual.
*Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations.
Example recommended EMI/EMC filter
NAC-16-472
*
A higher current rating EMI/EMC filter
may be recommended in view of the
other devices that could be connected
in parallel with the power supply.
High voltage pulse noise type : NAP series