Ordering information AC-DC Power Supplies Enclosed Type PJA100F PJ 1 A 100 2 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 C : with Coating R : Remote on/off (Required external power source) J : EP (Tyco Electronics) connector type J1 : VH (J.S.T.) connector type T : Vertical terminal block N2 : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS * Please consider "PBA100F-5-N" about 5V output with case cover. MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *3 LINE REGULATION[mV] LOAD REGULATION Io=30 to 100% *3 Io=0 to 30% [mV] 0 to +40C RIPPLE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% OUTPUT 0 to +40C RIPPLE NOISE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *8 INPUT-OUTPUT RC INPUT-FG ISOLATION *8 OUTPUT RC-FG *8 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *7 EFFICIENCY[%] PJA-2 PJA100F-12 PJA100F-15 PJA100F-24 PJA100F-36 PJA100F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) 1.2typ (Io=90%) 1.1typ (Io=100%) 0.6typ (Io=100%) 50 / 60 (47 - 63) 82typ (Io=90%) 83typ (Io=90%) 85typ (Io=90%) 86typ (Io=90%) 86typ (Io=90%) 82typ (Io=100%) 83typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 86typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 88typ (Io=100%) 89typ (Io=100%) 89typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.90typ (Io=100%) * Power factor correction is stopped at AC250V or more. 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 8.4 6.7 4.3 2.8 2.1 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 100.8 100.5 103.2 100.8 100.8 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max Burst operation (Please contact us about detail) 120max 120max 120max 150max 150max 160max 160max 160max 200max 400max 500max 500max 500max 500max 500max 150max 150max 150max 200max 200max 180max 180max 180max 240max 500max 600max 600max 600max 600max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 500typ (ACIN 115V, Io=100%) Ta=25C 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PJA100F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY 41X97X109mm [1.61X3.82X4.29 inches] (Excluding terminal block and screw) (WXHXD) / 500g max Convection 5 years (subject to the operating conditions) OTHERS *5 hour warm-up at 25C. *3Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at 30% load or less. *4Output power derating is required. See 3.2 in Instruction Manual. *5See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *6 *7Consult us about other classes. *8 The RC terminal is added to option -R models. The RC terminal is isolated *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. When the load factor is 0 - 30%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. *2Drift is the change in DC output for an eight hour period after a half- from input, output, and FG. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Compact design (Depth: 109mm 4.29inches) - High efficiency (88%typ PJA100F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J, -J1), and complies with SEMI F47 (see instruction manual 1.1) - Various connection interface options (vertical terminal [-T], AMP connector [-J], [-J1]) Block diagram FUSE 250V 3.15A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG RC(-R) CURRENT SENSING BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING EXTERNAL SOURCE CONTROL OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER INVERTER CONTROL DC OUT External view The external size of -R option, -J option, -J1 option, -N2 option and -T option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 2-M3 Name plate Mounting hole (Bottom side) M3.5 AC(L) Terminal cover AC(N) Point A 97 [3.82] [0.49] 760.5 [2.99] 109 [4.29] [0.55] 4 101 [0.16] [3.98] 33.5 [1.32] 66.50.5 [2.62] 41 [0.71] [1.61] [0.47] 12 180.5 [0.83] 28.5 21 [1.12] 3.5 [0.14] 15.31.5 (LED) [0.83] 9.5 [0.37] 6.2 51 19.5 [0.77] 12.5max 141.5 Tolerance : 1 [0.04] [0.6] Weight : 500g max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Aluminum Cover material : Galvanizing steel Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m max Screw tightening torque : M3.5 1.0N-m max Connect the input FG to safety earth ground. [2.01] 2 1 CN4 Connector for Remote ON/OFF (option) 3.5 21 [0.14] 11.21.5 (potentiometer) [0.44] [0.24] 221.5 [0.57] 14.61.5 32.81.5 [1.29] 8.2 Output terminal(+) Output voltage adjustable potentiometer LED [0.87] Output terminal(-) [0.32] FG( ) 3-M3 Mounting hole PJA-3 Ordering information AC-DC Power Supplies Enclosed Type PJA150F PJ 1 A 150 2 3 F 4 Example recommended EMI/EMC filter NAC-04-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 C : with Coating R : Remote on/off (Required external power source) J : EP (Tyco Electronics) connector type J1 : VH (J.S.T.) connector type T : Vertical terminal block N2 : with DIN rail See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS * Please consider "PBA150F-5-N" about 5V output with case cover. MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *3 LINE REGULATION[mV] LOAD REGULATION Io=30 to 100% *3 Io=0 to 30% [mV] 0 to +40C RIPPLE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% OUTPUT 0 to +40C RIPPLE NOISE[mVp-p] *1 -10 to 0C Io: load factor Io=0 to 30% 0 to +40C TEMPERATURE REGULATION[mV] -10 to +40C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *8 INPUT-OUTPUT RC INPUT-FG ISOLATION *8 OUTPUT RC-FG *8 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *7 EFFICIENCY[%] PJA-4 PJA150F-12 PJA150F-15 PJA150F-24 PJA150F-36 PJA150F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) 1.7typ (Io=90%) 1.6typ (Io=100%) 0.8typ (Io=100%) 50 / 60 (47 - 63) 84typ (Io=90%) 84typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 87typ (Io=90%) 84typ (Io=100%) 84typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 87typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 90typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.93typ (Io=100%) * Power factor correction is stopped at AC250V or more. 16typ (Io=90%) Ta=25C at cold start 16typ (Io=100%) Ta=25C at cold start 32typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 12.5 10 6.4 4.2 3.2 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 150.0 150.0 153.6 151.2 153.6 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max Burst operation (Please contact us about detail) 120max 120max 120max 150max 150max 160max 160max 160max 200max 400max 500max 500max 500max 500max 500max 150max 150max 150max 200max 200max 180max 180max 180max 240max 500max 600max 600max 600max 600max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 500typ (ACIN 115V, Io=100%) Ta=25C 20typ (ACIN 115V, Io=100%) 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 43.20 to 52.80 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 54.00 to 67.20 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL62368-1, C-UL (CSA62368-1), EN62368-1, UL508 (Except option -J, -J1) Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PJA150F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY 41X97X129mm [1.61X3.82X5.08 inches] (Excluding terminal block and screw) (WXHXD) / 600g max Convection 5 years (subject to the operating conditions) OTHERS *5 hour warm-up at 25C. *3Consult us about dynamic load and input response. Measure the output voltage by using the average mode of the tester to deal with the burst operation at 30% load or less. *4Output power derating is required. See 3.2 in Instruction Manual. *5See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *6 *7Consult us about other classes. *8The RC terminal is added to option -R models. The RC terminal is *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. When the load factor is 0 - 30%, the switching power loss is reduced by burst operation, which will cause ripple and ripple noise to go beyond the specifications. *2Drift is the change in DC output for an eight hour period after a half- isolated from input, output, and FG. Do not use the power supply in overcurrent conditions or in unspecified input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. * Features - Compact design (Depth: 129mm 5.08inches) - High efficiency (90%typ PJA150F-24, AC230Vin, 100% load) - Low power consumption (1.5W typ AC240Vin, no load at standard model) - UL508 approved (Except option -J, -J1), and complies with SEMI F47 (see instruction manual 1.1) - Various connection interface options (vertical terminal [-T], AMP connector [-J], [-J1]) Block diagram FUSE 250V 4A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG RC(-R) CURRENT SENSING BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING EXTERNAL SOURCE CONTROL OVER VOLTAGE PROTECTION INVERTER RECTIFIER AND FILTER INVERTER CONTROL DC OUT External view The external size of -R option, -J option, -J1 option, -N2 option and -T option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. Name plate 2-M3 Mounting hole (Bottom side) Point B M3.5 AC(L) Terminal cover AC(N) Point A 97 [3.82] 49.5 [1.95] 3.5 11.21.5 (potentiometer) 21 [0.14] 9.5 [0.37] [0.57] 14.61.5 [0.87] 221.5 LED 32.81.5 [1.29] Output voltage adjustable potentiometer B [0.24] Output terminal(+) 6.2 8.2 Output terminal(-) [0.32] FG( ) 2 1 CN4 Connector for Remote ON/OFF (option) 19 960.5 [3.78] [0.75] 12.5max 129 [0.49] [5.08] [0.44] 4 121 [4.76] [0.83] 48 [1.89] 700.5 [2.76] 41 [1.61] 3.5 21 [0.83] 28.5 [1.12] [0.14] [0.16] [0.47] [0.71] [0.55] 15.31.5 (LED) Tolerance : 1 [0.04] [0.6] Weight : 600g max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Aluminum Cover material : Galvanizing steel Dimensions in mm, [ ]=inches Mounting torque : 0.49N-m max Screw tightening torque : M3.5 1.0N-m max Connect the input FG to safety earth ground. 12 180.5 141.5 3-M3 Mounting hole PJA-5 Ordering information AC-DC Power Supplies Enclosed Type PJA300F PJ 1 A 2 300 3 F 4 Example recommended EMI/EMC filter NAC-06-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment R : Remote on/off (Required external power source) F4: Low speed fan See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-100V CURRENT[A] ACIN 100V-264V ACIN 85-100V WATTAGE[W] ACIN 100V-264V *3 LINE REGULATION[mV] LOAD REGULATION[mV] *3 0 to +50C RIPPLE[mVp-p] *1 -10 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -10 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -10 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *9 INPUT-OUTPUT RC INPUT-FG ISOLATION *9 OUTPUT RC-FG *9 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *8 EFFICIENCY[%] PJA-6 PJA300F-5 PJA300F-12 PJA300F-15 PJA300F-24 PJA300F-36 AC85 - 264 1f (Output derating is required at AC85V - 100V. See 1.1 and 3.2 in Instruction Manual) 3.5typ (Io=100%) 3.9typ (Io=100%) 3.0typ (Io=100%) 3.3typ (Io=100%) 1.5typ (Io=100%) 1.7typ (Io=100%) 50 / 60 (47 - 63) 73typ (Io=100%) 79typ (Io=100%) 81typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) 74typ (Io=100%) 80typ (Io=100%) 82typ (Io=100%) 83typ (Io=100%) 83typ (Io=100%) 77typ (Io=100%) 82typ (Io=100%) 84typ (Io=100%) 86typ (Io=100%) 87typ (Io=100%) 0.99typ (Io=100%) 0.98typ (Io=100%) 0.95typ (Io=100%) 20typ (Io=100%) Ta=25C at cold start 20typ (Io=100%) Ta=25C at cold start 40typ (Io=100%) Ta=25C at cold start 0.75max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) 5 12 15 24 36 Output derating is required at ACIN 100V or less (refer to instruction manual 3.2) 50 25 20 12.5 8.4 Output derating is required at ACIN 100V or less (refer to instruction manual 3.2) 250 300 300 300 302.4 20max 48max 60max 96max 144max 40max 100max 120max 150max 150max 80max 120max 120max 120max 150max 140max 160max 160max 160max 160max 120max 150max 150max 150max 200max 160max 180max 180max 180max 240max 50max 120max 150max 240max 360max 75max 180max 180max 290max 440max 20max 48max 60max 96max 144max 300typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 LED (Green) Not provided Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PJA300F-48 82typ (Io=100%) 83typ (Io=100%) 86typ (Io=100%) 48 6.3 302.4 192max 300max 150max 400max 200max 500max 480max 600max 192max 43.20 to 52.80 48.00 to 49.92 55.20 to 67.20 PJA300F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS 102X41X190mm [4.02X1.61X7.48 inches] (Excluding terminal block and screw) (WXHXD) / 1.0kg max Forced cooling (internal fan) 5 years (subject to the operating conditions) *7 *5 *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3Consult us about dynamic load and input response. *4Output power derating is required. See 3.2 in Instruction Manual. *5See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *6 *7The fan speed slows down at no load. *8Consult us about other classes. *9The RC terminal is added to option -R models. The RC terminal is isolated from input, output, and FG. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is not possible with this mode. *Sound noise may be heard from the power supply when used for pulse load. Features - Cost-effective - Longer life (see Instruction Manual) - Low profile (meets 1U height = 41 mm or 1.61 inches) - Wide operating temperature range (-20 - Slow fan speed at no load to +70 see instruction manual) - Complies with SEMI F-47 - Many optional functions Block diagram FUSE 250V 10A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER FG CURRENT SENSING BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING CONTROL CONTROL OVER VOLTAGE PROTECTION INVERTER CONTROL INVERTER RECTIFIER AND FILTER THERMAL PROTECTION CONTROL DC OUT FAN External view The external size of -V option and -R option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 16.81.5 (LED) [0.66] [0.78] 4-M4 Mounting Hole (Bottom side) 102 [2.36] 600.5 -V [4.02] 6.7 [0.26] [0.79max] 10 -V FG [5.91] 190 [0.65] 5max 19.5 [0.77] 1500.5 [5.91] 10.5 [0.98] 250.5 [0.2max] AIR FLOW [0.41] Tolerance : 1 [0.04] Weight : 1.0kg max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Aluminum Case material : Galvanizing steel Dimensions in mm, [ ]=inches Mounting torque : 1.2N m max Screw tightening torque : 1.6N m max Connect the input FG to safety earth ground. [7.48] 41 1500.5 [1.61] 12.5 [0.49] 19.5 8.6 [0.34] M4 16.61.5 [0.77] Terminal cover AC AC (N) (L) FG( ) AC(N) AC(L) 20max [0.39] Output terminal(-) V.ADJ +V +V Output terminal(+) [0.49] Output voltage adjustable potentiometer Name plate 19.81.5 [0.23] LED 12.51.5 [0.5] 5.751.5 12.71.5 (potentiometer) 4-M4 Mounting Hole PJA-7 Ordering information AC-DC Power Supplies Enclosed Type PJA600F PJ 1 A 2 600 3 F 4 Example recommended EMI/EMC filter NAC-16-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series * A higher current rating EMI/EMC filter may be recommended in view of the other devices that could be connected in parallel with the power supply. -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *6 C : with Coating G : Low leakage current V : External potentiometer for output voltage adjustment W: Parallel operation, LV alarm and Remote sensing R : Remote on/off (Required external power source) F4 : Low speed fan See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-100V CURRENT[A] ACIN 100V-264V ACIN 85-100V WATTAGE[W] ACIN 100V-264V *7 LINE REGULATION[mV] LOAD REGULATION[mV] *7 0 to +50C RIPPLE[mVp-p] *1 -20 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -20 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *2 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF *3 INPUT-OUTPUT RC INPUT-FG ISOLATION *3 OUTPUT RC-FG *3 OUTPUT-RC OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *9 EFFICIENCY[%] PJA-8 PJA600F-5 PJA600F-12 PJA600F-15 PJA600F-24 PJA600F-36 AC85 - 264 1f (Output derating is required at AC85V - 100V. See 1.1 and 3.2 in Instruction Manual) 6.7typ (Io=100%) 7.5typ (Io=100%) 5.7typ (Io=100%) 6.5typ (Io=100%) 2.8typ (Io=100%) 3.2typ (Io=100%) 50 / 60 (47 - 63) 76typ (Io=100%) 81typ (Io=100%) 82typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 77typ (Io=100%) 82typ (Io=100%) 82typ (Io=100%) 85typ (Io=100%) 86typ (Io=100%) 79typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 0.99typ (Io=100%) 0.98typ (Io=100%) 0.95typ (Io=100%) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3sec to re-start) 1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) 5 12 15 24 36 Output derating is required at ACIN 100V or less (refer to instruction manual 3.2) 100 50 40 25 16.7 Output derating is required at ACIN 100V or less (refer to instruction manual 3.2) 500 600 600 600 601.2 20max 48max 60max 96max 144max 40max 100max 120max 150max 150max 80max 120max 120max 120max 150max 140max 160max 160max 160max 160max 120max 150max 150max 150max 200max 160max 180max 180max 180max 240max 50max 120max 150max 240max 360max 75max 180max 180max 290max 440max 20max 48max 60max 96max 144max 300typ (ACIN 100V, Io=100%) 20typ (ACIN 100V, Io=100%) 4.50 to 5.50 10.80 to 13.20 13.50 to 16.50 21.60 to 26.40 32.40 to 39.60 5.00 to 5.15 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 Works over 105% of rating and recovers automatically 5.75 to 7.00 13.80 to 16.80 17.25 to 21.00 27.60 to 33.60 41.40 to 50.40 LED (Green) Optional (Option -W) Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PJA600F-48 85typ (Io=100%) 85typ (Io=100%) 88typ (Io=100%) 48 12.5 600 192max 300max 150max 400max 200max 500max 480max 600max 192max 43.20 to 52.80 48.00 to 49.92 55.20 to 67.20 PJA600F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS *8 *5 120X61X215mm [4.72X2.40X8.46 inches] (Excluding terminal block and screw) (WXHXD) / 2.0kg max Forced cooling (internal fan) 5 years (subject to the operating conditions) *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. *2Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *3The RC terminal is added to option -R models. The RC terminal is isolated from input, output, and FG. *4Output power derating is required. See 3.2 in Instruction Manual. *5See 3.3 in Instruction Manual for more details. Consult us about safety agency approvals for the models with optional functions. *6 *7Consult us about dynamic load and input response. *8The fan speed slows down at no load. *9 Consult us about other classes. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. * Parallel operation is allowed for PLA600FA models with the -W option only. * Sound noise may be heard from the power supply when used for pulse load. Features - Cost-effective - Slow fan speed at no load - Longer life (see Instruction Manual) - Complies with SEMI F-47 - Low profile (meets 2U height = 61 mm or 2.40 inches) - Wide operating temperature range (-20 to +70 see instruction manual) - Many optional functions Block diagram FUSE 250V 16A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER BOOSTER INDUCTOR RECTIFIER AND FILTER CURRENT SENSING INVERTER FG CONTROL CURRENT SENSING RC (-R) External source THERMAL PROTECTION CONTROL PARALLEL-OPERATION CIRCUIT CONTROL Current balance (-W) Remote sensing (-W) OVER VOLTAGE PROTECTION DETECTING OUTPUT VOLTAGE LV alarm (-W) RECTIFIER AND FILTER INVERTER DC OUT CONTROL FAN External view The external size of -V option, -W option and -R option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 26.61.5 [1.05] 16.61.5 [0.65] 15.81.5(LED) Terminal cover [0.62] 23.81.5 [0.94] 18.51.5 4-M4 Mounting Hole (Bottom side) 7.4 [0.29] [0.83max] 10 [0.39] 120 [3.94] [4.72] 1000.5 [3.08] 78.31.5 12 [5.91] 10 215 3max [0.12max] AIR FLOW 35 [1.38] 1500.5 [5.91] 61 [1.5] 380.5 [8.46] [2.4] 1500.5 [0.61] Tolerance : 1 [0.04] Weight : 2.0kg max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Galvanizing steel Case material : Galvanizing steel Dimensions in mm, [ ]=inches Mounting torque : 1.5N-m max Screw tightening torque : M3.5 0.8N-m max M4 1.6N-m max Connect the input FG to safety earth ground. 35 [1.38] 15.5 15.61.5 M3.5 (AC,FG) [0.61] [0.39] 7.3 [0.29] FG AC AC (N) (L) 10 -V [0.39] -V [0.47] +V Output terminal (-) FG( ) AC(N) AC(L) Name plate 21max +V Output terminal (+) V.ADJ Output voltage adjustable potentiometer [0.73] M4 (+V,-V) LED [0.41] [0.46] 10.51.5 11.71.5(potentiometer) 4-M4 Mounting Hole PJA-9 Ordering information AC-DC Power Supplies Enclosed Type PJA1000F PJ 1 A 2 1000 3 F 4 Example recommended EMI/EMC filter NAC-20-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *8 C:w ith Coating G: L ow leakage current V:E xternal potentiometer for output voltage adjustment W : Parallel operation, LV alarm and Remote sensing R:R emote on/off ( Required external power source) U:O peration stop voltage is set at a lower value See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *2 LINE REGULATION[mV] LOAD REGULATION[mV] *2 0 to +50C RIPPLE[mVp-p] *1 -20 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -20 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *3 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG ISOLATION OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *5 EFFICIENCY[%] PJA-10 PJA1000F-12 PJA1000F-15 PJA1000F-24 PJA1000F-36 PJA1000F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) 12.5typ (Io=90%) 11.0typ (Io=100%) 5.5typ (Io=100%) 50 / 60 (47 - 63) 81typ (Io=90%) 82typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 82typ (Io=100%) 82typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) 15/30typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start) 15/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start) 30/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start) 1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 84 67 42 28 21 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 1008 1005 1008 1008 1008 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max 180max 180max 120max 150max 200max 240max 240max 160max 200max 500max 210max 210max 150max 200max 300max 270max 270max 180max 240max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 800typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 10.80 to 13.50 13.50 to 17.30 20.40 to 28.50 30.60 to 40.80 40.80 to 55.20 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 14.40 to 17.40 18.00 to 21.80 28.80 to 34.80 43.20 to 52.20 57.00 to 67.20 LED (Green) Optional (Option -W) Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL62368-1, C-UL (CSA62368-1), EN62368-1 Complies with DEN-AN Complies with FCC-B, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Complies with IEC61000-3-2 class A PJA1000F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS *6 *7 150X61X240mm [5.91X2.40X9.45 inches] (Excluding terminal block and screw) (WXHXD) / 2.8kg max Forced cooling (internal fan) 5 years (subject to the operating conditions) *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. *2Consult us about dynamic load and input response. *3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *4Output power derating is required. See 3.2 in Instruction Manual. *5 Consult us about other classes. *6The fan speed slows down or stops at no load. *7See 3.3 in Instruction Manual for more details. *8Consult us about safety agency approvals for the models with optional functions. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. *Parallel operation is not possible with this mode. Audible noise may be heard from the power supply when used for pulse load. * Features - Cost-effective - Longer life (see Instruction Manual) - Wide operating temperature range (-20 instruction manual) - Low profile (meets 2U height = 61 mm or 2.4 inches) - Stop or slow fan speed at no load to +70 see Block diagram FUSE 250V 20A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER BOOSTER INDUCTOR CURRENT SENSING RECTIFIER AND FILTER INVERTER FG CONTROL CURRENT SENSING RC (-R) External source THERMAL PROTECTION CONTROL PARALLEL-OPERATION CIRCUIT CONTROL Current balance (-W) Remote sensing (-W) OVER VOLTAGE PROTECTION DETECTING OUTPUT VOLTAGE LV alarm (-W) RECTIFIER AND FILTER INVERTER DC OUT CONTROL FAN External view [0.53] 13.5 10 [0.39] 4-M4 2-f9 29 [0.51] [0.62] [1.5max] [0.1] [0.16max] [5.16] [0.1] 150 [4.92] [5.91] 1250.5 8 [0.31] FG 161.5 [0.63] 10 M4 [0.39] AC (L) 13 [0.51] AC (N) FG( ) AC(N) AC(L) [2.4] 4max [9.45] 2.5 [0.94] 242.5 2.5 -V [3.92] [2.48] [2.76] +V 701.5 [1.14] 1310.5 V.ADJ Tolerance : 1 [0.04] Weight : 2.8kg max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Galvanizing steel Case material : Galvanizing steel Dimensions in mm, [ ]=inches Mounting torque : 1.5N-m max Screw tightening torque : 1.6N-m max Output terminal M4 tightening torque : 1.2N-m max Connect the input FG to safety earth ground. 99.51.5 63.11.5 Output terminal(-) 240 29 [0.93] [0.46] 23.72.5 11.71.5 (potentiometer) [0.57] 38max 14.5 [0.28] LED Output voltage adjustable potentiometer [7.76] 13 15.81.5 (LED) Output terminal(+) 8-M4 Mounting hole (Both sides) 1970.5 [1.14] 7 AIR FLOW 61 [1.5] 380.5 10 [0.39] 20 [0.79] 452 [1.77] 402 [1.57] [0.79] 202 20 [0.79] [0.59] 152 The external size of -V option, -W option and -R option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. Input terminal cover 23max [0.91max] Name plate 4-M4 Mounting hole (Bottom side) PJA-11 Ordering information AC-DC Power Supplies Enclosed Type PJA1500F PJ 1 A 2 1500 3 F 4 Example recommended EMI/EMC filter NAC-20-472 R High voltage pulse noise type : NAP series Low leakage current type : NAM series -O 5 -O 6 1 Series name 2 Single output 3 Output wattage 4 Universal input 5 Output voltage 6 Optional *8 C:w ith Coating G: L ow leakage current V:E xternal potentiometer for output voltage adjustment W : Parallel operation, LV alarm and Remote sensing R:R emote on/off ( Required external power source) U:O peration stop voltage is set at a lower value See 5.1 in Instruction Manual. *Make sure necessary tests will be carried out on your end equipment with the power supply installed in accordance with any required EMC/EMI regulations. SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] ACIN 100V ACIN 115V ACIN 230V FREQUENCY[Hz] ACIN 100V ACIN 115V ACIN 230V INPUT ACIN 100V POWER FACTOR ACIN 115V ACIN 230V ACIN 100V INRUSH CURRENT[A] ACIN 115V ACIN 230V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 85-115V CURRENT[A] ACIN 115V-264V ACIN 85-115V WATTAGE[W] ACIN 115V-264V *2 LINE REGULATION[mV] LOAD REGULATION[mV] *2 0 to +50C RIPPLE[mVp-p] *1 -20 to 0C OUTPUT 0 to +50C RIPPLE NOISE[mVp-p] *1 -20 to 0C 0 to +50C TEMPERATURE REGULATION[mV] -20 to +50C *3 DRIFT[mV] START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION PROTECTION OVERVOLTAGE PROTECTION[V] CIRCUIT AND OPERATING INDICATION OTHERS REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT INPUT-FG ISOLATION OUTPUT-FG OPERATING TEMP.,HUMID.AND ALTITUDE *4 STORAGE TEMP.,HUMID.AND ALTITUDE ENVIRONMENT VIBRATION IMPACT AGENCY APPROVALS SAFETY AND NOISE CONDUCTED NOISE REGULATIONS HARMONIC ATTENUATOR *5 EFFICIENCY[%] PJA-12 PJA1500F-12 PJA1500F-15 PJA1500F-24 PJA1500F-36 PJA1500F-48 AC85 - 264 1f (Output derating is required at AC85V - 115V. See 1.1 and 3.2 in Instruction Manual) 18typ (Io=90%) 16typ (Io=100%) 8typ (Io=100%) 50 / 60 (47 - 63) 81typ (Io=90%) 82typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 84typ (Io=90%) 82typ (Io=100%) 82typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 84typ (Io=100%) 85typ (Io=100%) 85typ (Io=100%) 88typ (Io=100%) 88typ (Io=100%) 87typ (Io=100%) 0.98typ (Io=90%) 0.98typ (Io=100%) 0.95typ (Io=100%) 15/30typ (Io=90%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start) 15/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start) 30/30typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 10sec to re-start) 1.5max (ACIN 240V, 60Hz, Io=100%, According to IEC62368-1 and DEN-AN) 12 15 24 36 48 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 125 100 64 42 32 Output derating is required at ACIN 115V or less (refer to instruction manual 3.2) 1500 1500 1536 1512 1536 48max 60max 96max 144max 192max 100max 120max 150max 150max 300max 180max 180max 120max 150max 200max 240max 240max 160max 200max 500max 210max 210max 150max 200max 300max 270max 270max 270max 240max 600max 120max 150max 240max 360max 480max 180max 180max 290max 440max 600max 48max 60max 96max 144max 192max 800typ (ACIN 115V, Io=100%) 20typ (ACIN 115V, Io=100%) 10.80 to 13.50 13.50 to 17.30 20.40 to 28.50 30.60 to 40.80 40.80 to 55.20 12.00 to 12.48 15.00 to 15.60 24.00 to 24.96 36.00 to 37.44 48.00 to 49.92 Works over 105% of rating and recovers automatically 14.40 to 17.40 18.00 to 21.80 28.80 to 34.80 43.20 to 52.20 57.00 to 67.20 LED (Green) Optional (Option -W) Optional (Required external power source. Option -R) AC3,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) AC2,000V 1minute, Cutoff current = 25mA, DC500V 50MW min (At room temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MW min (At room temperature) -20 to +70C (Output derating is required), 20 - 90%RH (Non condensing), 3,000m (10,000 feet) max -20 to +75C, 20 - 90%RH (Non condensing), 9,000m (30,000 feet) max 10 - 55Hz, 19.6m/s2 (2G), 3minutes period, 60minutes each along X, Y and Z axes 196.1m/s2 (20G), 11ms, once each X, Y and Z axes UL62368-1, C-UL (CSA62368-1), EN62368-1, Complies with DEN-AN Complies with FCC-A, VCCI-A, CISPR22-A, EN55011-A, EN55022-A, additional EMI/EMC Filter is required for meeting class B Complies with IEC61000-3-2 class A PJA1500F SPECIFICATIONS CASE SIZE/WEIGHT COOLING METHOD WARRANTY WARRANTY OTHERS *6 *7 178X61X268mm [7.01X2.40X10.55 inches] (Excluding terminal block and screw) (WXHXD) / 3.5kg max Forced cooling (internal fan) 5 years (subject to the operating conditions) *1This is the result of measurement of the testing board with capacitors of 22mF and 0.1mF placed at 150 mm from the output terminals by a 20 MHz oscilloscope or a ripple-noise meter equivalent to Keisoku-Giken RM103. See 1.6 of Instruction Manual for more details. *2Consult us about dynamic load and input response. *3Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. *4Output power derating is required. See 3.2 in Instruction Manual. *5 Consult us about other classes. *6The fan speed slows down or stops at no load. *7See 3.3 in Instruction Manual for more details. *8Consult us about safety agency approvals for the models with optional functions. Do not use the power supply in overcurrent conditions or in unspecified * input voltage ranges. Otherwise the internal components may be damaged. *Parallel operation is not possible with this mode. Audible noise may be heard from the power supply when used for pulse load. * Features - Cost-effective - Longer life (see Instruction Manual) - Wide operating temperature range (-20 instruction manual) - Low profile (meets 2U height = 61 mm or 2.4 inches) - Stop or slow fan speed at no load to +70 see Block diagram FUSE 250V 30A NOISE FILTER AC IN 85 - 264V INRUSH CURRENT LIMIT RECTIFIER BOOSTER INDUCTOR CURRENT SENSING RECTIFIER AND FILTER INVERTER FG CONTROL CURRENT SENSING RC (-R) External source THERMAL PROTECTION CONTROL PARALLEL-OPERATION CIRCUIT CONTROL Current balance (-W) Remote sensing (-W) OVER VOLTAGE PROTECTION DETECTING OUTPUT VOLTAGE LV alarm (-W) RECTIFIER AND FILTER INVERTER DC OUT CONTROL FAN External view 11.5 268 [10.55] [1.18] [8.46] 61 [2.4] 4max [0.16max] [0.93] 23.52.5 [0.1] 2150.5 [0.51] 8-M4 Mounting hole (Both sides) 8 [0.31] 178 [6.34] V.ADJ [7.01] 2.5 [0.1] 2.5 30 [8.46] 1610.5 -V [3.13] 1211.5 [4.76] [0.94] 242.5 [2.81] 71.51.5 +V 79.51.5 2150.5 38max [1.5max] Output terminal(+) 30 [1.18] 8.5 10 [0.62] 11.71.5 (potentiometer) [0.46] 13 [0.33] [0.39] [0.79] [0.28] 15.81.5 (LED) 10 [0.39] AC (L) 13 [0.51] AC (N) FG( ) AC(N) AC(L) M4 FG Tolerance : 1 [0.04] Weight : 3.5kg max PCB Material/thickness : FR-4 / 1.6mm [0.06inches] Chassis material : Galvanizing steel Case material : Galvanizing steel Dimensions in mm, [ ]=inches Mounting torque : 1.5N-m max Screw tightening torque : 1.6N-m max Output terminal M4 tightening torque : 1.2N-m max Connect the input FG to safety earth ground. AIR FLOW [1.5] 380.5 [0.79] 20 7 Output terminal(-) LED Output voltage adjustable potentiometer [0.45] 10 [0.59] 20 [0.79] 4-M4 2-f9 202 [1.77] 402 [1.57] 452 [0.39] 152 The external size of -V option, -W option and -R option models is different from the standard model. See "5. Options and Others" in Instruction Manual for more details. 161.5 [0.63] Input terminal cover 23max [0.91max] Name plate 4-M4 Mounting hole (Bottom side) PJA-13