313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
NLP110 Medical
Series
Single and
Triple Output
Special Features
• Provideslowvoltageoutputs
• CompliancetoEN61000-3-2
(PowerFactor=0.98)
• Package6.5x3.0x1.26inches
• 90Vacto264Vacuniversalinput
range
• UL,cUL,andVDEsafetyapprovals
• Overvoltageandshortcircuit
protection
• VDE0871-A,EN55022-A,
EN55011-Aconductednoise
• VDE0871-A,EN55022-A,
EN55011-Aradiatednoise
• Meetsallapplicableandrelevant
immunitystandardsEN61000-4-
2,4,5and6
• RoHScompliant
• 2yearwarranty
Total Power: 80-110W
Input Voltage: 90-264Vac
# of Outputs: Single,triple
Safety
• TUVEN60601-1/IEC601
• UL2601-12nd edition
• CSAC22.2No.601.1-M90
FileNo.E182560
Rev. 10.06.11_155
NLP110 Medical Series
1 of 4
ElectricalSpecications
Input
Inputrange: Universalinput
(SeeNote6) 90-264Vac
Frequency: 47-63Hz
Inputsurgecurrent:
(coldstart)
120Vac
230Vac
18Amax.
35Amax.
Safety ground
leakagecurrent: 230Vac,50Hz < 100µA
Inputcurrent: 120Vac@80W
120Vac@110W
230Vac@80W
230Vac@110W
0.9Arms
1.3Arms
0.48Arms
0.7Arms
Inputfuse: UL/IEC127 F3.15AH,250Vac
Output
Totalregulation:
(lineandload)
Mainoutput
Auxiliaryoutputs
±2.0%
±5.0%
Risetime: Atturn-on 1.0s,max.
Transientresponse: Mainoutput
75%to100%
stepat0.1Aµs
5.0%or250mV
max.dev.,1msmax.
recoveryto1%
Temperaturecoefcient: ±0.02%/°C
Overvoltageprotection: Mainoutputs 125%,±10%
Shortcircuitprotection: Cyclic operation Continuous
Minimumoutputcurrent: Single and multiple See table
Rev. 10.06.11_155
NLP110 Medical Series
2 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
EnvironmentalSpecications
Allspecicationsaretypicalatnominalinput,fullloadat25°Cunlessotherwisestated.
DERATING CURVE
Output Power (Watts)
0C 10C 20C 30C 40C 50C 60C 70C
40W
80W
110W 150 LFM FORCED
AIR COOLING
55W
NATURAL
CONVECTION
COOLING
EMCCharacteristics
Conductedemissions: EN55022,FCCpart15 LevelA
Radiatedemissions: EN55022,FCCpart15 LevelA
Harmoniccurrentemissioncorrection: EN61000-3-2 Compliant
ESDair: EN61000-4-2 Level3
ESDcontact: EN61000-4-2 Level3
Surge: EN61000-4-5 Level3
Fasttransients: EN61000-4-4 Level3
Radiatedimmunity: EN61000-4-3 Level3
Conductedimmunity: EN61000-4-6 Level3
GeneralSpecications
Hold-uptime: 120Vac,60Hz 16.7ms@110W
Efciency: 120Vac.80W(-9905J) 75%min.
Isolationvoltage: Input/output
Input/chassis
4000Vac
1500Vac
Approvalsandstandardspending: EN60601-1,IEC60601-1,VDE0750,UL2601-1,C22.2No.601.1-M90
Weight: 283g(10oz)
MTBFdemonstrated: MIL-HDBK-217F 220,000hoursmin.
Thermalperformance: Operating,ambient
(seederatingcurve)
0°Cto+50°C
Non-operating -40°Cto+85°C
50°Cto70°Cambientconvectioncooled Derateto50%load
0°Cto+50°C,ambientconvectioncooled 80W
0°Cto+50°C,ambient,150LFMforcedair 110W
Peak(0°Cto+50°C,60s) (SeeNote3)
Relativehumidity: Non-condensing 5%to95%RH
Altitude: Operating 10,000feetmax.
Non-operating 30,000feetmax.
Vibration(SeeNote5): 5-500Hz 2.4Grmspeak
Shock perMIL-STD-810E 516.4PartIV
Rev. 10.06.11_155
NLP110 Medical Series
3 of 4
Embedded Power for
Business-Critical Continuity
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Notes
1 Freeairconvection.
Multipleoutputunits:maximumcontinuousoutputpowernottoexceed
80 W.
For-9993J;I3.3V=13Amax.;I5.0V=13Amax.;I3.3V+ I5.0V²16A.
For-9994J;I3.3V=13Amax.;I2.5V=13Amax.;I3.3V+ I2.5V²16A
For-9995J;I3.3V=13Amax.;I12V=6.5Amax.;I3.3V+ I12V²16A.
For-9908J;I5.0V=13Amax.;I12V=6.5Amax.;I5.0V+ I12V²16A.
Singleoutputunits:maximumcontinuousoutputpowernottoexceed;75W
on-9905J;76.8Won-9912J,-9924J,and-9917J.
2 150LFMforcedaircoolingfromL4side.
Multipleoutputunits:maximumcontinuousoutputpowernottoexceed105
W.
For-9993J;I3.3V=16Amax.;I5.0V=16Amax.;I3.3V+ I5.0V²20A.
For-9994J;I3.3V=16Amax.;I2.5V=16Amax.;I3.3V+ I2.5V²20A
For-9995J;I3.3V=16Amax.;I12V=8.5Amax.;I3.3V+ I12V²20A.
For-9908J;I5.0V=16Amax.;I12V=8.5Amax.;I5.0V+ I12V²20A.
Singleoutputunits:maximumcontinuousoutputpowernottoexceed110 W
forallmodels.
3 300LFMforcedaircoolingfromL4side.
Multipleoutputunits:maximumcontinuousoutputpowernottoexceed110
W.
For-9993J;I3.3V=20Amax.;I5.0V=18Amax.;I3.3V+ I5.0V²22A.
For-9994J;I3.3V=20Amax.;I2.5V=20Amax.;I3.3V+ I2.5V²22A
For-9995J;I3.3V=20Amax.;I12V=8.5Amax.;I3.3V+ I12V²22A.
For-9908J;I5.0V=20Amax.;I12V=8.5Amax.;I5.0V+ I12V²22A.
Singleoutputunits:maximumcontinuousoutputpowernottoexceed110 W
forallmodels.
4 Peakoutputcurrentlastinglessthan30secondswithdutycyclelessthan
5%.Duringpeakloading,outputvoltagemayexceedtotalregulationlimits.
5 Figureispeak-to-peakforconvectionpowerrating.Outputnoise
measurementsaremadeacrossa20MHzbandwidthusinga6’twistedpair,
terminatedwitha10µFelectrolyticcapacitoranda0.1µFceramiccapacitor.
6 Minimumloadrequiredforcorrectstart-upandoperationonsingleoutputs
andonmainoutputofmultipleversions.Failuretoobserveminimum
loadonmainoutputwillnotallowthesupplytostart-upcorrectly.Some
electronictestloadshavealargedelaytimebeforetheystartdrawing
currenteventhoughthevoltagefromthesupplyispresent.Duringthistime
delay,thereisnoloadontheoutputandasaresult,thesupplycannotstart-
upproperlyandmaintainitscorrectoutputvoltage.Intheseinstances,a
dummyresistiveloadacrosstheoutputmaybenecessarytoloadtheoutput
ofthesupplyuntilthetestloadcanfunctioncorrectlyanddrawtheintended
minimumload.Minimumloadrequiredonauxiliaryoutputstomaintain
regulation.
7 FormodelsNLP110-9908JandNLP110-9995J,the12Voutputisoating.
For-12Voutput,pin11onJ2hastobeconnectedtoReturnmakingpin12
the-12Voutput
8 Threeorthogonalaxes,randomvibration10minutesforeachaxes,2.4Grms
5Hzto500Hz.
9 Foroptimumreliability,nopartoftheheatsinkshouldexceed110˚C,andno
semiconductorcasetemperatureshouldexceed120˚C.
10 CAUTION:Allowaminimumof1secondafterdisconnectinglinepower
whenmakingthermalmeasurements.
11 Thisproductisonlyforinclusionbyprofessionalinstallerswithinother
equipmentandmustnotbeoperatedasastandaloneproduct.
12 TheEMIspecicationsreferencemeasurementsmadewiththepowersupply
mountedonagroundedmetalsheetextending1inchbeyondeachedge,
usinganunshieldedcable.Noexternallteringrequiredduringconducted
emissionstestingbutsomeapplicationsmayrequireadditionalltering
toachievesystemcompliance.Alinechoke,(acinputcordsloopedtwice
throughanEMIsuppressiontoroid)wasusedduringradiatedemissions
testing.Considerableradiatedtestingin1Usix-sidedboxeshasshownthat
unitscanmeetlevelBintypicalsystems.Applicationsupportisavailable
fromthefactorytoassistwithEMIcompliance.
13 Allmodelsrequireaminimummountingstand-offof6.35mm(0.25inches)
intheenduseproduct.
14 The‘J’sufxindicatesthatthesepartsarePb-free(RoHS6/6)compliant.
15 NOTICE:Somemodelsdonotsupportalloptions.Pleasecontactyourlocal
EmersonNetworkPowerrepresentativeorusetheon-linemodelnumber
searchtoolathttp://www.Emerson.com/EmbeddedPower
OrderingInformation
Output
Voltage Min(6) Max(1) 150LFM(2) 300LFM(3) Peak(4) Ripple(5) Total
Regulation ModelNumbers(7,14,15)
+5V 0.5A 15A 22A 22A 22A 50mV ±2.0% NLP110-9905J
+12V 0.3A 6.4A 9.2A 9.2A 11.5A 120mV ±2.0% NLP110-9912J
+48V 0A 1.6A 2.3A 2.3A 2.5A 240mV ±2.0% NLP110-9917J
+24V 0.2A 3.2A 4.6A 4.6A 6.0A 240mV ±2.0% NLP110-9924J
+5V(A) 0.5A 13A 16A 18A 18A 50mV ±2.0% NLP110-9993J
+3.3V(B) 0.2A 13A 16A 20A 20A 50mV ±2.0%
+12V 0A 0.65A 1A 1A 1A 120mV ±5.0%
+3.3V(A) 0.5A 13A 16A 20A 22A 50mV ±2.0% NLP110-9994J
+2.5V(B) 0.1A 13A 16A 20A 22A 50mV ±2.0%
+12V 0A 0.65A 1A 1A 1A 120mV ±5.0%
+12V(A) 0.2A 6.5A 8.5A 8.5A 10A 1200mV ±2.0% NLP110-9995J
+3.3V(B) 0.5A 13A 16A 20A 22A 50mV ±2.0%
-12V 0A 0.65A 1A 1A 1A 120mV ±5.0%
+12V(A) 0.2A 6.5A 8.5A 8.5A 10A 120mV ±2.0% NLP110-9908J
+5V(B) 0.2A 13A 16A 18A 22A 50mV ±2.0%
-12V 0A 0.65A 1A 1A 1A 120mV ±5.0%
313
process
yellow
3405
1797
1375
116
2607
652
242
2985
375
240
Embedded Power for
Business-Critical Continuity
Rev. 10.06.11_155
NLP110 Medical Series
4 of 4
0.23
(5.842)
6.50
(165.10)
1T1 (REF.)
J4
J1
6.050
(153.670)
2.550
(64.770)
ALL DIMENSIONS IN INCHES (mm)
J2
J3
1
1
2
12
3.00
(76.20)
F1
J5 2
1
0.23
(5.842)
!
3
MAXIMUM COMPONENT HEIGHT
IS 1.26 (32.00)
2
3
4
1
Recommendeddirection
forforcedairrelativeto
power supply orientation
shownbelow.
1 Optimum.
2 Verygood.
3 Good.
4 Notrecommended.
InputPinConnections
J1
Pin1 ACNeutral
Pin2 NoConnection
Pin3 ACLine
J3
Pin1 V(A)Sense+
Pin2 V(A)Sense-
J4
Pin1 SafetyEarth
J5
Pin1 V(B)Sense+
Pin2 V(B)Sense-
Output Pin Connections
J2 Single Triple
Pin1 NoConnection V(B)
Pin2 NoConnection V(B)
Pin3 NoConnection V(B)
Pin4 Return Return
Pin5 Return Return
Pin6 Return Return
Pin7 Return Return
Pin8 V(A) V(A)
Pin9 V(A) V(A)
Pin10 V(A) V(A)
Pin11 NoConnection V(C)
Pin12 NoConnection V(C)Return(7
Inputandoutputconnectors Matingconnectors
AC (J1) connector type
Molex26-60-4030orequivalent. AC (J1) mating connector type
Molex09-50-3031orequivalentwithMolex08-50-0105or
equivalentcrimpterminals.
DC (J2) connector type
12positionMolexSpoxtype26-48
1125orequivalent.
DC (J2) mating connector type
MolexSpoxtype26-03-3121andcontact08-52-0113.
Sense (J3) connector type
Molex22-23-2021orequivalent. Sense (J3) mating connector type
Molex22-01-3027andcontact08-50-0113.
Earth (J4) connector type
Male0.250quickdisconnect. Earth (J4) mating connector type
Molex90028.
Sense (J5) connector type
Leoco2421P02H000. Sense (J5) mating connector type
Leoco2420S020000andcontact2453TPB00V1.
Americas
5810VanAllenWay
Carlsbad,CA92008
USA
Telephone:+17609304600
Facsimile: +17609300698
Europe (UK)
WaterfrontBusinessPark
MerryHill,Dudley
WestMidlands,DY51LX
UnitedKingdom
Telephone:+44(0)1384842211
Facsimile: +44(0)1384843355
Asia (HK)
14/F,LuPlaza
2WingYipStreet
KwunTong,Kowloon
HongKong
Telephone:+85221763333
Facsimile: +85221763888
Forglobalcontact,visit:
www.Emerson.com/EmbeddedPower
techsupport.embeddedpower
@emerson.com
Whileeveryprecautionhasbeentakentoensure
accuracyandcompletenessinthisliterature,Emerson
NetworkPowerassumesnoresponsibility,anddisclaims
allliabilityfordamagesresultingfromuseofthis
informationorforanyerrorsoromissions.
EmersonNetworkPowerandtheEmerson
NetworkPowerlogoaretrademarksand
servicemarksofEmersonElectricCo.
©2011EmersonElectricCo.
EmersonNetworkPower.com
Embedded Computing
Embedded Power
Monitoring
Outside Plant
PowerSwitching&Controls
Precision Cooling
Racks&IntegratedCabinets
Services
Surge Protection
Emerson Network Power.
Thegloballeaderinenabling
business-criticalcontinuity.
ACPower
Connectivity
DCPower