497B 1604
Power Protection Phoenix Contact
2894
PHOENIX CONTACT Surge Protection Devices
A
B
C
D
E
F
G
H
I
J
SURGE PROTECTION DEVICES FOR WIRELESS DATA, SIGNAL, AND MOBILE PHONE SYSTEMS
The unit can be mounted directly to the coaxial cable, or attached to the bulkhead with the use of a mounting bracket.
Uses a removable gas tube for easy replacement if direct lightning strike causes a failure.
Impedance matching allows high transmission capabilities without signal attenuation or degradation.
Metal housing provides superior shielding (EMI/RFI) properties for high-speed data interfaces. For quantities greater than listed, call for quote.
MOUSER STOCK NO. Fig. Phoenix Type Description MCOV
DC/AC
Price Each
Mfr. Mfr. Part No. 1 10 25
651
-
2818148 A CN-UB-280DC-SB For Coax Cables, Type N Male-BNC Female 280V/195V 99.00 91.08 88.20
651
-
2818850 A CN-UB-280DC-BB For Coax Cables, Type N Female-BNC Female 280V/195V 99.00 91.08 88.20
SURGE PROTECTION DEVICE FOR VIDEO SURVEILLANCE SYSTEMS
C-UFB/E and CTNC-UFB/E have been specially designed to meet demands of video systems with isolated (oating) grounds.
The protection circuits feature a hybrid circuit with fast acting silicon avalanche diode arrays line to shield and high current handling gas discharge tube protection line to shield, line to
ground, and shield to ground.
C-UFB are for video systems with grounded shield connections. Protected circuit features a hybrid circuit with a fast acting silicon avalanche diode array and high current handling gas
discharge tube protection circuit line to shield (ground).
Degree of protection in acc. with IEC 60529/EN 60 529 IP 20, Test Standards: IEEE C62.36. For quantities greater than listed, call for quote.
MOUSER STOCK NO. Fig. Phoenix Type Description MCOV
DC/AC
Price Each
Mfr. Mfr. Part No. 1 5 10
651
-
2797861 B C-UFB-24DC Signal Voltage 24V, BNC Female/Male, 50 30V/21V 165.00 156.70 151.80
SURGE PROTECTION DEVICE FOR ISDN AND T1 INTERFACES
Hybrid circuit provides low clamping voltage with high surge current discharge capability.
Metal housing provides superior shielding (EMI/RFI) properties for high-speed data interfaces.
Special designs for high data transmission without attenuation.
Degree of protection in acc. with IEC 60529/EN 60 529 IP 20, Test Standards: IEEE C62.36. For quantities greater than listed, call for quote.
MOUSER STOCK NO. Fig. Phoenix Type Description MCOV
DC/AC
Price Each
Mfr. Mfr. Part No. 1 10 25
651
-
2856113 CPT 1x2-BE Base for PT 2/ISDN NT-ST 128V/90V 49.17 45.23 43.81
SURGE PROTECTION DEVICE FOR ANALOG PHONE LINES (POTS)
Telecommunications protection with RJ12/RJ45 female connectors can be used internationally for the protection of analog telecom interfaces, such as, telephones, telefaxes, modems,
and answering machines with a maximum operating voltage of 185 V.
D-FM-A/RJ45-BB this product series is connected for analog phone lines (POTs). Hybrid silicon avalanche diode array and Gas Discharge Tube provides tight clamping voltage line to
line on each signal pair and high surge current handling capacity line to line, line to shield, and shield to ground.
MT-2FM-RJ12 is a DIN rail mount version of the D-FM-A/RJ45-BB. Ideal for RTU applications where phone lines are used for Telemetry. The IN and OUT connects can be made via
screw clamp terminal blocks. The OUT side can be connected with RJ11 and RJ12 connectors. All 4 lines of interface are protected.
Degree of protection in acc. with IEC 60529/EN 60 529 IP 20, Test Standards: IEEE C62.36. For quantities greater than listed, call for quote.
MOUSER STOCK NO. Fig. Phoenix Type Description MCOV Price Each
Mfr. Mfr. Part No. 1 10 25
651
-
2818795 D D-FM-A/RJ45-BB Protect Adapt for Analog,RJ45 Female/Female 185VDC 162.00 149.04 144.34
Used for high frequency applications
Discharge surge current is 60KA VSWR in a 50 ohm system is 1.15dB or less from 2.4-5.9GHz
Protects 802.11 radio and Bluetooth Uses lambda/4 branch line technology
SURGE PROTECTION FOR ANTENNA CONNECTIONS
For quantities greater than listed, call for quote.
MOUSER STOCK NO. Fig. Phoenix Type Description Price Each
Mfr. Mfr. Part No. 1 5 10
651
-
2838490 F CD-LAMBDA/4-5.9-BB CoaxTRAB, protective adapter for antenna connections 115.00 109.21 105.80
SURGE PROTECTION FOR DATA NETWORKS/ETHERNET
Metal housing improves shielding and overall performance.
Independent testing certies low attenuation and interference requirements of CAT 5E cabling with 10/100 Base T Ethernet.
All eight pins of the RJ45 connection are protected, ensuring complete protection independent of connector wiring. For quantities greater than listed, call for quote.
MOUSER STOCK NO. Fig. Phoenix Type Description MCOV Price
Each
Mfr. Mfr. Part No.
651
-
2859084 E D-LAN-CAT.5E-U Adapt LAN with Universal DIN Rail Mount Foot 7V DC 120.00
mouser.com/phoenix-contact (800) 346-6873
© Copyright 2016 Mouser Electronics
© Copyright 2016 Mouser Electronics
For quantities greater than listed, call for quote.
MOUSER
STOCK NO. Phoenix Type Fig. Description Price
Each
651-2801487 VAL-MS-AR 75 VF GModule, for up to 60 V AC/DC, hybrid Type 2 surge protection with zero leakage current 117.00
651-2801488 VAL-MS-AR 75 VF/FM GModule, for up to 60 V AC/DC, hybrid Type 2 surge protection with zero leakage current, function
monitor contacts
132.00
651-2801065 VAL-MS BE-AR GBase element for surge protection, with disconnect; DIN rail mount with retention screw; no surge
protection plug
51.00
651-2801066 VAL-MS BE-AR/FM GBase element for surge protection, with disconnect; DIN rail mount with retention screw; function
monitoring contacts; no surge protection plug
66.00
Bridge
651-2801068 FBS 2-18 HBridge for parallel circuits, 2 pos. 2.72
VAL-MS BE-AR SURGE PROTECTION AND CONNECTION
FOR RAILROAD CONTROLS AND SIGNALS
Modern form of Surge Protection for the Railroad Industry for newer electronics and control systems.
Faster installation compared to AAR Surge Protection currently being used
Pluggable surge protection for quick repairs
Protects systems from direct lightning strikes and coupled surge energy
Local status indication on plugs for easy location of expired plugs
Optional remote status indication through dry contacts
Simple, tool-free disconnect pin and test point for isolating eld wires during maintenance and insulation resistance test
SURGE PROTECTION FOR PHOTOVOLTAIC (PV) SYSTEMS
For quantities greater than listed, call for quote.
MOUSER
STOCK NO. Phoenix Type Fig. Description Price
Each
651-2800674 VAL-MS-T1/T2 175/12.5/1+1-FM ILightning arrester for 1-phase power 175V L-N max, separate N and PE (3-conductor
system: L, N, PE), with remote indication contact.
290.00
651-2800672 VAL-MS-T1/T2 175/12.5/3+0-FM ILightning arrester for 3-phase power 175V L-N max, common N and PE (4-conductor system:
L1, L2, L3, PEN), with remote indication contact.
460.00
Power & Signal Quality -
TRABTECH
Pluggable DIN rail mount surge protection
UL Recognized: File Number E330181
PT-IQ INTELLIGENT MCR SURGE PROTECTION DEVICE
For quantities greater than listed, call for quote.
MOUSER
STOCK NO. Phoenix Type Fig. Description Price
Each
651-2800780 PT-IQ-2X1-12DC-UT J DIN Rail, Screw, 12V, Protective plug & base element, with integrated multi-stage status indicator on
the module for two signal wires with common reference potential
185.00
Pluggable
UL Listed: File Number E138168
Impedance neutral plugging
Insulation measurement without disconnection
T-Bus connection for power and data transmission
Easy and error-free installation
Fast and clear identication of status onsite
Fast and automatic integration of SPDs without wiring
Controller monitors and sends status reports to the control room
Error message in case of incomplete assembly
Protection, shield connection and unlimited extension
Protection of up to ve single wires
Available in oating and directly grounded shield
connections
Reduced installation cost - One power terminal block
powers 28SPDs
Real-time, multi-stage monitoring and plug replacement
beforehand prevents unnecessary servicing