Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 1 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Ceramic package DCC6C
Features
Low-loss RF cleanup filter for mobile telephone
PCS systems, transmit path
Usable passband 30 MHz
High nearby selectivity
Ceramic package for Surface Mounted
Technology (SMT)
Terminals
Ni, gold-plated
Dimensions in mm, approx. weight 0,05 g
Pin configuration
2 Input
3 Input - ground
5 Output
4 Output - ground
1,6 To be grounded
Electrostatic Sensitive Device (ESD)
Type Ordering code Marking and Package
according to Packing
according to
B4114 B39861-B4114-U410 C61157-A7-A67 F61074-V8088-Z000
Maximum ratings
Operable temperature range
T
– 30 / + 85 ˚C
Storage temperature range
T
stg – 40 / + 85 ˚C
DC voltage
V
DC 0V
Source power
P
s3 dBm source impedance 50
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 2 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Characteristics
Operating temperature range:
T
= -30 to +85˚C
Terminating source impedance:
Z
S= 50
Terminating load impedance:
Z
L= 50
min. typ. max.
Center frequency
f
c 862,0 MHz
Maximum insertion attenuation αmax
847,0 ... 877,0 MHz 2,8 3,4 dB
Amplitude ripple (p-p) ∆α
847,0 ... 877,0 MHz 1,1 1,7 dB
Input VSWR 847,0 ... 877,0 MHz 2,4 2,6
Output VSWR 847,0 ... 877,0 MHz 2,4 2,6
Relative attenuation (relative to αmax)αrel
0,0 ... 820,0 MHz 32,0 37,0 dB
820,0 ... 838,0 MHz 16,0 19,0 dB
905,0 ...2200,0 MHz 23,0 26,0 dB
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 3 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Characteristics of 2 filters in cascade 1)
Operating temperature range:
T
= -30 to +85˚C
Terminating source impedance:
Z
S= 50
Terminating load impedance:
Z
L= 50
1) Cascaded filters matched to each other with parallel coupling coil of 10 nH.
2) In temperature range -20 to +85˚C.
min. typ. max.
Center frequency
f
c 862,0 MHz
Maximum insertion attenuation αmax
847,0 ... 877,0 MHz 5,5 7,0 dB
Amplitude ripple (p-p) ∆α
847,0 ... 877,0 MHz 2,1 3,6 dB
847,0 ... 877,0 MHz 2) 2,1 3,0 dB
Input VSWR 847,0 ... 877,0 MHz 2,8 3,5
Output VSWR 847,0 ... 877,0 MHz 2,8 3,5
Relative attenuation (relative to αmax)αrel
0,0 ... 820,0 MHz 60,0 75,0 dB
820,0 ... 838,0 MHz 31,0 34,0 dB
905,0 ...2200,0 MHz 35,0 40,0 dB
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 4 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Characteristics of 2 filters in cascade 1)
Operating temperature range:
T
= -30 to +85˚C
Terminating source impedance:
Z
S= 50
Terminating load impedance:
Z
L= 50
1) Cascaded filters directly connected to each other without matching network.
2) In temperature range -20 to +85˚C.
min. typ. max.
Center frequency
f
c 862,0 MHz
Maximum insertion attenuation αmax
847,0 ... 877,0 MHz 5,5 7,0 dB
Amplitude ripple (p-p) ∆α
847,0 ... 877,0 MHz 2,1 3,6 dB
847,0 ... 877,0 MHz 2) 2,1 3,0 dB
Input VSWR 847,0 ... 877,0 MHz 3,9 4,4
Output VSWR 847,0 ... 877,0 MHz 3,9 4,4
Relative attenuation (relative to αmax)αrel
0,0 ... 820,0 MHz 60,0 75,0 dB
820,0 ... 838,0 MHz 31,0 34,0 dB
905,0 ...2200,0 MHz 35,0 40,0 dB
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 5 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Measured transfer function(2 filters B4114 in cascade with 10nH parallel coupling coil):
Measured transfer function(wideband,2 filters B4114 in cascade with 10nH parallel coupling coil):
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 6 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Measured transfer function(2 filters B4114 in cascade without parallel coupling coil):
Measured transfer function(wideband, 2 filters B4114 in cascade without parallel coupling coil):
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 7 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Reflection functions(2 filters B4114 in cascade with 10nH parallel coupling coil):
Preliminary format of data sheet.
Terms of delivery and rights to change design reserved. OFW SIN E
Page 8 of 8 Jun 10, 1999
SAW Components
Data Sheet
B4114
862,00 MHz
Low Loss Filter for Mobile Communication
Reflection functions(2 filters B4114 in cascade without parallel coupling coil):