COOLX(R)1800 HIGH EFFICIENCEY, INTELLIGENT AND RELIABLE 1800 W MODULAR POWER SUPPLIES Advanced Energy's CoolX(R)1800 series, part of our low voltage solutions, is an intelligent modular power supply. The CoolX1800 delivers an incredible 1800 W in a compact 1U high package with PMBusTM digital communications, control and reliability in addition to the most comprehensive feature set and specifications available. AT A GLANCE PRODUCT HIGHLIGHTS Modular Power Supply Up to 1800 W Up to 12 outputs All outputs isolated (1850 VAC) Variable fan speed control Reliability MTBF > 200,000 hours Level 4 input surge protection 23.5 W always ON auxiliary power output Safety approved to 5000 m altitude 93% efficiency Five-year warranty Flexibility Analog and digital management -- PMBusTM monitoring and control capability Field-configurable -- plug and play power Series and parallel outputs for higher voltages and currents Mounting options -- base/side and DIN-Rail mounting TYPICAL APPLICATIONS Medical Clinical diagnostic equipment, medical lasers, dialysis equipment, radiological imaging, chemical chemistry Industrial Test and measurement, industrial machines, automation equipment, printing, telecommunications, MIL-COTS Audio Equipment H i Rel, harsh industrial electronics, radar (marine- and ground-based), communications, test and measurement CX18S CX18M Power 1800 W 1800 W Slots 6 6 Cooling Variable fan speed control Parameters 267 mm x 127 mm x 41 mm (10.5 in x 5 in x 1U) Certifications Medical (CX18M) IEC60601-1 3rd edition, IEC60601-1-2 4th edition (EMC) 2 MOPP Dual fused ISO13485 Industrial (CX18S) IEC60950, IEC62368-1 SEMI F47 Defense/Aero (All Models) MIL-STD-810G COOLX1800 SERIES MODULES CoolX CoolMods Table Single Output Modules (1 Slot) Vnom(V) Set Point Adjust Range (V) Imax(A) Power (W) CmA 5 2.5-6.0 30.0 150 CmB 12 6.0-15.0 23.3 280 CmC 24 15.0-28.0 12.5 300 CmD 48 28.0-58.0 6.25 300 1 2 3 High Power Modules (3 Slot) CmE4 24 22.8-25.2 37.5 900 CmF4 48 45.6-50.4 18.75 900 Dual Output Modules (1 Slot) CmG5 CmH V1 24 3.0-30.0 4.0 120 V2 24 3.0-30.0 4.0 120 V1 5 3.0-6.0 10.0 60 V2 24 3.0-30.0 4.0 120 CmA-W01 5 1.0-6.0 30 150 CmB-W01 12 1.0-15.0 23.3 280 CmC-W01 24 2.0-28.0 12.5 300 CmD-W01 48 3.0-58.03 6.25 300 6 Wide Trim Modules (1 Slot) 2 1 Full dynamic specifications may not be met at full load when output voltage is trimmed above 13 V. 2 Max Trim 14 V when used with High Power Module 3 Max Trim 56 V when used with High Power Module 4 a) Only one High Power module (CmE or CmF) can be used per CoolPac. b) During load transients starting from 0% load on the High Power modules, other modules in the CoolPac may experience an output voltage dynamic during the load change. Contact applications support for details or support.. 5 For the CmG module the max combined power of both outputs is 200 W. 6 For the CmH module the max combined power of both outputs is 180 W. *SEMI F47 compliant at input voltages > 180 VAC. Consult Advanced Energy for details. 2 advancedenergy.com COOLX1800 SERIES ELECTRICAL SPECIFICATIONS Input Parameter Conditions/Description Min Nom Max Units Nominal Input Voltage Range Universal Input 47-440Hz 100 -- 240 VAC 85 -- 264 VAC Maximum for 5 seconds -- -- 300 VAC 300 VDC 90 VAC @ 1800 W -- -- 14.5 A AC Operating Input Range Extended AC Operating Range DC Input Voltage Range Input Current 120 Inrush Current 230 VAC @ 1800 W -- -- 25 A Power Factor 120 VAC @ 1400 W 0.98 -- -- -- Undervoltage Lockout Shutdown 65 -- 74 VAC Input Fuses Rating Dual Fused (Line and Neutral) 250 VAC -- 16 -- A Efficiency 230 VAC, 1800 W with 6 x CmC CoolMods 91 230 VAC, 1800 W with 2 x CmF CoolMod -- 93 -- % Parameter Conditions/Description Min Nom Max Units Power Rating CX18: See derating curves % Output Minimum Load Line Regulation -- -- 1800 W 0 -- -- A For 10% change from nominal line -- -- 0.1 % CmE, CmF, CmG, CmH -- -- 0.5 % Load and Cross Regulation For 25% to 75% load change -- -- 0.2 % Transient Response Voltage Deviation, for 25% to 75% load change 0.5A/uS -- -- 4 (4) % Settling Time, *CmE and CMF in () -- -- 500 (1000) S Ripple and Noise 100 mV or 1.0% pk-pk. 20 MHz BW -- -- 1 CmF -- -- 1.5 % Overvoltage Protection Tracking OVP Level (N/A in CmE and CmF, CmG, CmH) 105 -- 125 % Latching OVP Level 125 -- 160 % Remote Sense Max. line drop compensation (N/A in CmG and CmH) -- -- 0.5 VDC -- -- 1 % Overshoot Rise Time Capacitive Load Turn-On Delay Hold-Up Time % Monotonic -- -- 10 ms CmG and CmH -- -- 20 ms CmA-CmE 10 mF CmG, CmH < 0.47 mF From AC in -- -- 1000 ms From Global Enable -- -- 10 ms From CoolMod Enable -- -- 10 -- For nominal output voltages at full load CmE and CmF combination at 1300 W 16 -- -- ms CoolMod Power As per CoolMod table -- -- -- -- Output Adjustment Range Manual: Multi-turn potentiometer. As per CoolMod table -- -- -- -- Vtrim: As per CoolMod table -- -- -- -- Overcurrent Protection Straight line with hiccup activation @ 35% Vo nom CmE, CmF, CmG, CmH: Current limit hiccup autorecovery 110 130 150 % Short Circuit Protection Yes, Autorecovery -- -- -- -- OverTemperature Protection Yes, Autorecovery (CmG, CmH latch off ) -- -- -- -- advancedenergy.com 3 COOLX1800 SERIES ELECTRICAL SPECIFICATIONS (CONTINUED) Auxiliary Output Parameter Conditions/Description Min Nom Max Units Auxiliary Output Voltage Aux Voltage Option A 11.76 12 12.24 V Aux Voltage Option B Load Regulation 4.75 5 5.25 V -- -- 2 % Line Regulation For 10% change from nominal line -- -- 0.5 % Maximum Output Current Aux Voltage Option A -- -- 1.96 A Aux Voltage Option B Load Capacitance -- -- 4.7 A -- -- 1000 uF 140 % -- -- -- Output Overcurrent Protection Hiccup 110 Short Circuit Protection Yes, Autorecovery -- Galvanic Isolation Parameter Conditions/Description Min Nom Max Units Input to Output Reinforced (2 x MOPP); contact Advanced Energy for Hi-Pot instructions 4000 -- -- VAC Input to Case Basic (1 x MOPP) 1850 -- -- VAC Output to Case Basic (1 x MOPP) 1850 -- -- VAC Output to Output Basic (1 x MOPP) 1850 -- -- VAC CmG, CmH V1-V2 Operational 500 -- -- VDC Reliabilty Parameter Conditions/Description Min Nom Max Units Reliability and MTBF MTBF of >>3 million hours, Telecordia SR-332, Issue 4 CoolPac (excludes fans) -- 0.33 -- Fpmh Warranty 5 years -- -- -- -- Parameter Conditions/Description Min Nom Max Units Operating Temperature Operates to specification below -20C after 10 min warmup Environmental Storage Temperature -40 -- 70 C -40 -- 85 C Derating See derating curves -- -- -- -- Relative Humidity Non-condensing 5 -- 95 %RH Shock and Vibration MIL-STD-810G Method 514.6 Altitude 4 advancedenergy.com -- -- -- -- -- -- 5000 m COOLX1800 SERIES ELECTRICAL SPECIFICATIONS (CONTINUED) Leakage Currents Parameter Conditions/Description AC Leakage Current Input to earth ground Nom Units Normal Condition (High Line) Mains Voltage 264 VAC/60 Hz 244 A Single Fault Condition (High Line) Mains Voltage 264 VAC/60 Hz 435 A Touch Current Normal Condition Mains Voltage 264 VAC/60 Hz 14.2 A Single Fault Condition Mains Voltage 264 VAC/60 Hz 246 A EMC Parameter Conditions/Description Notes Radiated Emissions EN 55011, EN 55022 and FCC, Class B -- Compliant Conducted Emissions1 EN 55011, EN 55022 and FCC, Class B -- Compliant Power Line Harmonics EN 61000-3-2, Class A -- Compliant Voltage Flicker EN 61000-3-3 -- Compliant ESD EN 61000-4-2, level 4, 8 kV contact, 15 kV air -- A Radiated Immunity EN 61000-4-3, level 3, 10 V/m 80-2700 MHz -- A Electrical Fast Transient EN 61000-4-4, level 4, 4 kV -- A Surge Immunity EN 61000-4-5, level 4, 2 kV DM, 4 kV CM -- A Conducted RF Immunity EN 61000-4-6, level 3, 10 Vemf 150 KHz-80 MHz 1 -- A Power Frequency Magnetic Field EN 61000-4-8, level 4, 30 A/m -- A Voltage Dips and Interruptions 10 ms 100 ms 500 ms A B B EN61000-4-11 1 Consult AE applications for system level compliance Standards and Directives Standard Conditions/Description Safety Agency Approvals EN60601-1 3rd Edition, UL60601-1, CSA601, EN60950 2nd Edition, CSA C22.2 No. 60950-1 IEC/EN 60950-1, Edition 2 and all national deviations UL 60950-1/CSA 22.2 No 60950-1, Edition 2; 5000 m (16,400 ft) altitude, 100 VAC to 240 VAC 10% IEC/EN 60601-1, Edition 3 and all national deviations IEC 60601-1 (2005), EN60601-1 (2006), ANSI/AAMI ES 60601-1 (2005), CAN/CSA C22.2 No. 60601-1 (2008); 5,000 m (16,400 ft) altitude, 100 VAC to 240 VAC 10% IEC 62368 Edition 2 IEC 62368-1 (2014) Edition 2; 5000 m (16,400 ft) altitude, 100 VAC to 240 VAC 10% IEC 60601-1-2 Edition 4 IEC 60601-1-2 (2014) Protection class Class I ROHS EU DIRECTIVE 2015/863 RoHS compliant REACH-171 Compliant Conflict Materials Compliant with Conflict Free Sourcing Initiative advancedenergy.com 5 COOLX1800 SERIES MECHANICAL SPECIFICATIONS Mechanica Data Parameter Description Dimensions (L x W x H) LxWxH 267 mm x 127 mm x 41 mm (10.5" x 5" x 1U) Weight Nominal Weight: CoolPac + 6 x CoolMods 1.6 Kg Connectors Description Mating Connectors (if applicable) AC/DC IEC input (Option) Screw terminal Block and IEC inlet options. -- In Mating Connectors column state "See Interface page" Main DC output terminal block (CmA-CmF, CmM-CmQ) M4 Screws -- Main DC output terminal block (CmG, CmH) Camden - CTB9350/4A -- Output Signal Connector (CmG, CmH) Molex - 87833-0831 Camden - CTB9200/4A or Wurth Elektronik - 691 352 710 004 System Signal Connector J1007 Molex 87833-0831 8-way Locking Molex 51110-0860; Non Locking Molex 51110-0850; Crimp Terminal: Molex p/n 50394 or Molex 51110-0856 which includes locking tab and polarization keying Output Signal Connectors J1001-1006 Molex 87833-0631 6-way Locking Molex 51110-0660; Non Locking Molex 51110-0650; Crimp Terminal: Molex p/n 50394 or Molex 51110-0656 which includes locking tab and polarization keying Output Signal Connector (CmG, CmH) Molex 87833-0831 8-way Locking Molex 51110-0860; Non Locking Molex 51110-0850 Crimp Terminal: Molex p/n 50394 or Molex 51110-0856 which includes locking tab and polarization keying Output Sense Connectors J3 JST-S2BPH-K(LF)(SN) JST PHR2. Crimp Terminal JST BPH-002TP.0.5S or SPH-002TP.05S Auxiliary Output Connector J1 Molex 1041880210 2pin 6 advancedenergy.com COOLX1800 SERIES MECHANICAL SPECIFICATIONS (CONTINUED) Mechanical Drawings 4 1 Standard airflow direction * Maximum screw penetration from base does not exceed 2mm. advancedenergy.com 7 COOLX1800 SERIES EFFICIENCY AND DERATING CURVES Efficiency vs Load Current & Power Overload Characteristics 92 140 90 120 Output Voltage (%) Efficiency (%) 88 86 84 82 80 78 100 80 60 40 20 76 0 20 40 60 80 100 0 120 0 20 40 Load (%) Vo Nom 1800 1800 1600 1600 1400 1400 800 600 8 advancedenergy.com Vmax 600 200 Power Vo hiccup 800 400 Input Voltage (Vac) 140 1000 200 80 100 120 140 160 180 200 220 240 260 120 1200 400 0 100 CX18 Temperature Derating Curve 2000 Output Power (W) Output Power (W) CX18 Input Voltage Typical Derating Curves 2000 1000 80 Output Current (%) 240V 1200 60 0 -30 -20 -10 0 10 20 30 40 50 Ambient Temperature (C) IEC Terminal Block 60 70 80 COOLX1800 SERIES INTERFACE (CONTINUED) Input Connectors Standard (Screw Terminal) Option 1 (IEC Terminal) CoolPac Connectors advancedenergy.com 9 COOLX1800 SERIES INTERFACE (CONTINUED) CoolMod Connectors 10 advancedenergy.com COOLX1800 SERIES CONFIGURATION *CmE or CmF High Power Module (3 slot module) can only occupy Slots D/E/F. Configuration Example 1 CoolX part number CX18S-ADG##E-N-A specifies the following product; * CX18S 1800W IEC60950 approved * Slot 1: CmA: 2.5-6.0V (150W) * Slot 2: CmD: 28-58V (300W) * Slot 3: CmG: Dual output 3-30V (120 per channel) * Slot 4: Not Available (CmE is three slot CoolMod module) * Slot 5: Not Available (CmE is three slot CoolMod module) * Slot 6: CmE: 22.8-25.2 (900W) * Option N: Nominal Output voltage settings * Option A: 12V/(1.96)A Bias Supply Voltage Configuration Example 2 CoolX part number CX18M-BABBDC-N-B specifies the following product; * CX18M 1800W IEC60601-1 approved * Slot 1: CmB: 6-15V (280W) * Slot 2: CmA: 2.5-6.0V (150W) * Slot 3: CmB: 6-15V (280W) * Slot 4: CmB: 6-15V (280W) * Slot 5: CmD: 28-58V (300W) * Slot 6: CmC: 15-28V (300W) * Option N: Nominal Output voltage setting * Option B: 5V/(4.7A) Nominal Output voltage setting advancedenergy.com 11 ABOUT ADVANCED ENERGY Advanced Energy (AE) has devoted more than three decades to perfecting power for its global customers. AE designs and manufactures highly engineered, precision power conversion, measurement and control solutions for mission-critical applications and processes. AE's power solutions enable customer innovation in complex semiconductor and industrial thin film plasma manufacturing processes, demanding high and low voltage applications, and temperature-critical thermal processes. With deep applications know-how and responsive service and support across the globe, AE builds collaborative partnerships to meet rapid technological developments, propel growth for its customers and power the future of technology. Specifications are subject to change without notice. Not responsible for errors or omissions. (c)2019 Advanced Energy Industries, Inc. All rights reserved. For international contact information, visit advancedenergy.com Advanced Energy(R) and AE(R) are U.S. trademarks, and CoolX(R) is a U.S. and Europe trademark of Advanced Energy Industries, Inc. ENG-LV-COOLX1800-235-07 12.19