G9EH-1 DC Power Relay (300A type) Capable of Interrupting Highvoltage, High-current Loads * A compact relay (L111 x W60x H76.7mm) capable of switching DC400V, 300A. (Capable of interrupting max. DC300V, 2500A) * The switching section and driving section are gas-injected and hermetically sealed, allowing these compact relays to interrupt high-current. The sealed construction also achieves no arc space, space saving, and helps to ensure safe applications. In addition, the contacts have a high contact reliability that is unaffected by ambient atmosphere. * Downsizing of parts and optimum design allow no restrictions on the mounting direction. Type standard G9EH-@-@-@-@ Classification Symbol Number of contact poles 1 Symbol Meaning of the symbol 1 pole Contact structure Blank Coil terminal form Blank 1a contact Connector terminal Automotive use Blank Available for automotive use Classification Terminal form Classification Switching / current conduction type Coil terminals Contact terminals Connector terminal Screw terminals Contact structure Rated coil voltage 1a DC12V DC24V Type name G9EH-1 Note: Come with two M8 nuts for main terminals (contacts). Ratings DC Power Relay Operation coil Rated voltage (V) Rated current (mA) Coil resistance () DC 12 583 20.6 DC 24 292 82.3 Operating voltage (V) Release voltage (V) Maximum voltage (V) Power consumption (W) 75% or less of rated voltage 8% or more of rated voltage 130% of rated voltage (at 23C within 10min.) Approx. 7 Note:1. Values of the rated current and the coil resistance are at coil temperature of +23C, and have a tolerance of 10%. 2. The figures for the operating characteristics are at a coil temperature of 23C. 3. Value of the maximum voltage is the maximum voltage that can be applied to the relay coil. Switching area Item Rated load Resistance load G9EH-1 DC400V 300A Rated current 300A Maximum switching voltage 400V Maximum switching current 300A G9EH-1 DC Power Relay (300A type) Performance Item G9EH-1 Contact resistance *1 30 m or less (Typ. 0.2 m) Contact voltage drop 0.1V or less (at 300A) Operating time 50 ms or less Release tim 30 ms or less Insulation resistance*2 Withstand voltage Vibration tolerance Shock resistance Between coil and contacts 1,000 M or more Between homopolar contacts 1,000 M or more Between coil and contacts AC2,500V for 1min. Between homopolar contacts AC2,500V for 1min. Durability 5 to 200 to 10Hz Single amplitude 0.75mm (Acceleration: 2.94 to 88.9m/s2) Malfunction 5 to 200 to 5Hz Single amplitude 0.75mm (Acceleration: 2.94 to 88.9m/s2) Durability 490 m/s2 Malfunction 200 m/s2 Mechanical endurance *3 Electrical endurance (Resistance load) *4 Short time carry current Maximum interruption current Overload interruption Reverse polarity interruption 200,000 times or more DC400V 200A 3,000 times or more DC400V 300A 1,000 times or more 450A (for 10 min) DC400V 2,500A (1 time) DC400V 700A (40 times or more) DC200V -200A (1,000 times or more) Minimum load current 1A Ambient temperature 40 to +85C (with no icing or condensation) Ambient humidity 5% to 85%RH Weight (including accessories) Approx. 850g All values above are in early time under an ambient temperature of +23C unless stated. Measurement condition: By voltage drop method at DC5V 1A. Measurement condition: By insulation resistance at DC500V. Test condition / Switching frequency: 3,600 times/hour. Test condition / Switching frequency: 60 times/hour. DC Power Relay Note: *1. *2. *3. *4. G9EH-1 DC Power Relay (300A type) Dimensions (Unit: mm) Relay with Connector G9EH-1 Connector part number: 7282-1020 (Yazaki) Note: Harness side Female connector number: 7283-1020 Terminal arrangement / Internal connections (BOTTOM VIEW) 111 92 79 28.6 1(+) 2(-) 60 47 32.1 27 Size (mm) Note: Be sure to connect terminals with the correct polarity. Coils do not have polarity. Tolerance (mm) to 10 0.3 10 to 50 0.5 50 to 1 59 2-M8 NUT 11 89.8 67.8 12510 Mounting holes (BOTTOM VIEW) 2-M8 Hole: 3-M6 or f6.5 15 3 76.7 64.9 71.6 73.6 64.9 61.7 48.8 79.23 20.5 10 (31.55) 61.55 DC Power Relay 46.53