Bel Power Solutions MAP80 Series of power supplies provides
reliable, tightly-regulated DC power for commercial and industrial
systems which require high peak current capabilities. Wide-range AC
input and full international safety, EMI, and ESD compliance ensure
worldwide acceptance. All units bear the CE Mark.
The MAP80 utilizes a variable frequency design with a thermally
efficient U-channel chassis to provide full power operation in
convection-cooled applications. Design innovations include metric
and SAE mounting inserts on each mounting surface to provide
integration flexibility. Dual-mode connectors provide traditional
terminal block connections or popular single-row Molex connector
mating.
Single-output models feature wide-range output adjustability to meet
a wide variety of standard and user-specific output voltage
requirements.
RoHS Compliant
Wide Range Input for 110/220 VAC Applications
CE marked to Low Voltage Directive
Input Transient and ESD Compliance to EN61000-4-2/-3/-4
Meets EN55022, Class B Limits
TTL Compatible Power Fail Signal
Greater than 175,000 Hours MTBF
Metric and SAE Mounting Inserts
2
MAP80 Series
tech.support@psbel.com
MODEL7
OUTPUT
VOLTAGE
MAX
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT1
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE2
INITIAL SETTING
ACCURACY
MAP80-1012G6
12V/15V
7.5/6.0A3
9.2/7.3A
0.2%
±1%
1%
11.76V to 12.15V
MAP80-1024G6
24V/28V
3.8/3.2A
4.6/3.9A
0.1%
0.5%
0.5%
23.8V to 24.2V
MODEL7
OUTPUT
VOLTAGE
ADJUSTMENT
RANGE
OUTPUT
CURRENT
PEAK
OUTPUT
CURRENT4
LINE
REGULATION
LOAD
REGULATION
RIPPLE
&
NOISE2
INITIAL SETTING
ACCURACY
MAP80-4000G5
+5V
4.8V to 5.5V
14A
16A
0.2%
1%
1%
5.1V to 5.2V
+12V
11.52V to 12.48V
4A
7A
0.2%
1%
1%
11.9V to 12.1V
-5V
Fixed
1A
1A
0.5%
2%
1%
-4.8V to -5.4V
-12V
Fixed
1A
1A
0.5%
2%
1%
-11.5V to -12.5V
MAP80-4001G5
+5V
4.8V to 5.5V
14A
16A
0.2%
1%
1%
5.1V to 5.2V
+24V
23.04V to 24.96V
2A
3.5A
0.2%
1%
1%
24.0V to 24.1V
-12V
Fixed
1A
1A
0.5%
2%
1%
-11.5V to -12.5V
+12V
Fixed
1A
1A
0.5%
2%
1%
11.5V to 12.5V
MAP80-4002G5
+5V
4.7V to 5.5V
14A
16A
0.2%
1%
1%
5.1V to 5.2V
+12V
11.52V to 12.48V
4A
7A
0.2%
1%
1%
12.0V to 12.1V
-12V
Fixed
1A
1A
0.5%
2%
1%
-11.6V to -12.4V
+12V
Fixed
1A
1A
0.5%
2%
1%
11.6V to 12.4V
MAP80-4003G5
+5V
4.8V to 5.5V
14A
16A
0.2%
1%
1%
5.1V to 5.2V
+15V
14.4V to 15.6V
3.5A
6A
0.2%
1%
1%
14.6V to 15.1V
-5V
Fixed
1A
1A
0.5%
2%
1%
-4.8V to -5.4V
-15V
Fixed
1A
1A
0.5%
2%
1%
-14.4V to -15.5V
MAP80-4004G5
+5V
4.8V to 5.5V
14A
16A
0.2%
1%
1%
5.1V to 5.2V
+24V
23.04V to 24.96V
2A
3.5A
0.2%
1%
1%
24.0V to 24.1V
-15V
Fixed
1A
1A
0.5%
2%
1%
-14.4V to -15.5V
+15V
Fixed
1A
1A
0.5%
2%
1%
14.4V to 15.5V
MAP80-4010G5
+5V
4.8V to 5.5V
14A
16A
0.2%
1%
1%
5.1V to 5.2V
+12V
11.52V to 12.48V
4A
7A
0.2%
1%
1%
12.0V to 12.1V
-5V
Fixed
1A
1A
0.5%
2%
1%
-4.8V to -5.4V
-12V
Fixed
3A
3A
0.5%
2%
1%
-11.5V to -12.5V
1
Peak load for 60 seconds or less are acceptable, 10% duty cycle, maximum.
2
Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth.
3
MAP80-1012 output currents are expressed as 12V/15V operation. MAP80-1024 output currents are expressed as 24V/28V operation.
4
Peak loads up to 90 Watts for 60 seconds or less are acceptable, (10% duty cycle max.). Peak power must not exceed 90 Watts.
5 Output rated 65 W max for 50°C ambient, convection cooled.
6 Output rated 75 W max for 50°C ambient, convection cooled.
7 Non-G models use lead solder exemption and are not recommended for new designs.
MAP80 Series
3
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2018 Bel Power Solutions & Protection
BCD.00565_AE
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Input Voltage - AC
Continuous input range
90
175
135
264
VAC
Input Frequency
AC input
47
63
Hz
Brown Out Protection
Lowest AC input voltage that regulation is maintained with full rated
loads.
90
VAC
Hold-up Time
Nominal AC input voltage (115VAC), full rated load.
20
ms
Input Current
90 VAC (80 W load)
110VAC (80W load)
2.5
1.8
ARMS
Input Protection
Non-user serviceable internally located AC input line fuse.
Inrush Surge Current
Internally limited by thermistor, Vin = 264 VAC (one cycle), 25° C
45
APK
Operating Frequency
Switching frequency of power supply (varies with load)
22
120
kHz
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Efficiency
Full load @ 115 VAC. Varies with distribution of loads among
outputs.
73% typical
Minimum Loads
MAP80-1012
MAP80-1024
All multiple output models, main channel only
0.42
0.21
1.50
Amps
Ripple and Noise
Full load, 20 MHz bandwidth.
See Model Selection Chart
Output Power
Continuous output power, all multiple output models.
Peak output power (60s maximum, 10% duty cycle), all multiple
output models.
80
90
Watts
Overshoot / Undershoot
Output voltage overshoot/undershoot at turn-on, V1, V2.
1
%
Regulation
Varies by output. Total regulation includes: line changes from
90-132 VAC or 175-264, changes in load starting at 20% load and
changing to 100% load.
See Model Selection Chart
Transient Response
Recovery time, to within 1% of initial set point due to a 50-100%
load change, 4% max. deviation. (Main output of multiple output
units).
500
μs
Turn-on Delay
Time required for initial output voltage stabilization.
1
5
Sec
Turn-on Rise Time
Time required for output voltage to rise from 10% to 90%.
20
ms
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Overvoltage Protection
Provided on the main output of multiple output units.
MAP80-1012
MAP80-1024
5.5
17.5
32
6.8
23
37
V
Overload Protection
Fully protected against output overload and short circuit.
Automatic recovery upon removal of overload condition.
Power Fail Warning 8
Logic LO (denotes power fail detected).
0.7
V
Logic HI with internal pull-up to output.
5.1
kΩ
Power Fail trip point, maximum load, decreasing line.
86
94
VAC
Time before regulation dropout, at full load, due to loss of input power.
4
ms
8 Power Fail Warning is not available for MAP80-1024. The MAP80-1012 is an open collector output, capable of sinking 35 mA, maximum
4
MAP80 Series
tech.support@psbel.com
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Agency Approvals
Approved to the latest edition of the following standards;
UL/CSA60950-1 2nd, IEC60950-1 2nd and EN60950-1 2nd.
Dielectric Withstand Voltage
Input to Chassis
Input to Output (tested by manufacturer only)
2121
4242
VDC
Electromagnetic Interference,
Conducted
FCC CFR title 47 Part 15 Sub-Part B - conducted & radiated.
EN55022 / CISPR 22 conducted.
EN55022 / CISPR 22 radiated.
B
B
B
Class
Input Transient Protection
EN61000-4-5 Level 3
Line to Line
Line to Ground
1
2
kV
Insulation Resistance
Input to output
7
MΩ
Leakage Current
Per EN60950, 264 VAC
500
μA
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating
Non-operating
10k
40k
ASL Feet
Operating Temperature9
Derate linearly above 50°C by 2.5% per °C
to a maximum temperature of 70°C
At 100% load:
At 50% load:
0
0
50
70
°C
Storage Temperature
-40
85
°C
Temperature Coefficient
0°C to 70°C (after 15 minute warm-up)
±0.02
±0.03
%/°C
Relative Humidity
Non-condensing
5
95
%RH
Shock
Operating, peak acceleration
20
G
Vibration
Random vibration, 10Hz to 2kHz, 3 axis
6
GRMS
9 The use of an external cooling fan (100LFM (linear feet per minute), minimum) shall be determined at end use if the 25°C ambient is exceeded.
PARAMETER
CONDITIONS / DESCRIPTION
MIN
NOM
MAX
UNITS
Dimensions
182.9 x 106.7 x 45.7
7.2 x 4.2 x 1.8
mm
in
Weight
0.82
1.8
kg
lb
Cover (Option)
Add ‘C’ suffix to model number or order part number 412-59585-G
separately.
For convection cooled applications, derate output power to 65 watts
on all multiple output models and MAP80-1005. Derate MAP80-
1012 and MAP80-1024 to 75 watts.
Dimensions:
182.9 x 106.7 x 50.0
7.20 x 4.20 x 1.97
mm
in
MAP80 Series
5
Asia-Pacific
+86 755 298 85888
Europe, Middle East
+353 61 225 977
North America
+1 408 785 5200
© 2018 Bel Power Solutions & Protection
BCD.00565_AE
CONNECTOR
CONDITIONS / DESCRIPTION
Input & Output Connectors
6-32 screw wire clamps on 0.312" (7.9 mm) centers,
0.045" (1.1 mm) square pins on 0.156" (3.9 mm) centers, mates with Molex series 2139, 6442, or 41695
Matting Connectors
J1: 0.035" (0.9 mm) square pins on 0.100" (2.5 mm) centers, mates with Molex series 2695/6471
Chassis
0.090" (2.3 mm) aluminum alloy, with clear finish
Figure 1. Mechanical Drawing
NUCLEAR AND MEDICAL APPLICATIONS - Products are not designed or intended for use as critical components in life support systems,
equipment used in hazardous environments, or nuclear control systems.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on
the date manufactured. Specifications are subject to change without notice.