40 Super Capacitors Vol.03
Specifications: FR Series
Specifications
–40˚C to +85˚C
5.5 Vdc
Refer to standard ratings
+80 %, –20 %
Refer to standard ratings
Refer to standard ratings
Capacitance More than 90 % of initial requirement
Equivalent Series Resistance
Not to exceed 120 % of initial requirement
Current at 30 minutes
Not to exceed 120 % of initial requirement
Capacitance More than 50 % of initial value
Equivalent Series Resistance
Not to exceed 4 times initial value
Capacitance More than 30 % of initial value
Equivalent Series Resistance
Not to exceed 7 times initial value
Capacitance Not to exceed 200 % of initial value
Equivalent Series Resistance
Not to exceed initial requirement
Current at 30 minutes
Not to exceed 1.5 CV (mA)
Capacitance Within ±20 % of initial value
Equivalent Series Resistance
Not to exceed initial requirement
Current at 30 minutes
Not to exceed initial requirement
No loosening nor permanent damage of the leads
Capacitance Meet initial requirement
Equivalent Series Resistance
Meet initial requirement
Current at 30 minutes
Meet initial requirement
3/4 or more of the pin surface shoud be covered with new solder
Capacitance Meet initial requirement
Equivalent Series Resistance
Meet initial requirement
Current at 30 minutes
Meet initial requirement
Capacitance Meet initial requirement
Equivalent Series Resistance
Meet initial requirement
Current at 30 minutes
Meet initial requirement
Capacitance Within ±20% of initial value
Equivalent Series Resistance
Not to exceed120 % of initial requirement
Current at 30 minutes
Not to exceed120 % of initial requirement
Item
Operating Temperature Range
Maximun Working Voltage
Nominal Capacitance Range
Capacitance Allowance
Equivalent Series Resistance
Current (30-minute Value)
Surge Voltage
Phase 2
Phase 3
Phase 5
Phase 6
Lead Strength (Tensile)
Vibration Resietance
Solderability
Soldering Heat
Resistance
Temperature Cycle
Humidity Resistance
Test Conditions
Conforming to JIS C 5102-1994
Refer to characteristics measuring conditions
Refer to characteristics measuring conditions
Refer to characteristics measuring conditions
Conform to 7.14
Surge voltage 6.3 V
Temperature : 85±2˚C
Charge: 30 sec.
Discharge: 9 min. 30 sec.
1 000 cycles
Charge resistance:
0.022 F 560 Ω
0.047 F 300 Ω
0.10 F 150 Ω
0.22 F 56 Ω
0.47 F 30 Ω
1.0 F 15 Ω
Discharge resistance:
Not applicable (0 Ω)
Conform to 7.12
Phase 1: +25±2˚C
Phase 2: –25±2˚C
Phase 3: –40±2˚C
Phase 4: +25±2˚C
Phase 5: +85±2˚C
Phase 6: +25±2˚C
Conform to 8.1.2 (1)
0.022 to 0.47 F: 1 kg, 10 sec.
1 F: 2.5 kg, 10 sec.
Conform to 8.2.3
Frequency: 10 to 55 Hz
Test duration: 6 hours
Conform to 8.4
245 ±5˚C
5 ±0.5 sec. 1.6 mm from body
Conform to 8.5
260 ±10˚C, 10 ±1 sec.
Immersion depth:
1.6 mm from body
Conform to 9.5
40 ±2˚C, 90 to 95% RH
240 ± 8 hours
Temperature
Variation of
Characteristics
Conform to 9.3
Temperature condition:
–40°C → normal temperature
→ +85°C → normal temperature
Number of cycles: 5 cycles