E-Series Surface Mount Mixer
5 – 1000 MHz MAMXES0115
V4
1 • North America Tel: 800.366.2266 • Europe Tel: +353.21.244.6400
• India Tel: +91.80.4155721 • China Tel: +86.21.2407.1588
Visit www.macomtech.com for additional data sheets and prod uct information.
M/A-COM Technology Solutions Inc. and its affiliates reserve the right to make
changes to the product(s) or information contained herein without notice.
ADVANCED: Data Sheets contain information regarding a product M/A-COM Technology Solutions
is considering for development. Performance is based on target specifications, simulated results,
and/or prototype measurements. Commitment to develop is not guaranteed.
PRELIMINARY: Data Sheets contain information regarding a product M/A-COM Technology
Solutions has under development. Performance is based on engineering tests. Specifications are
typical. Mechanical outline has been fixed. Engineering samples and/or test data may be available.
Commitment to produce in volume is not guaranteed.
Features
• LO Power +7 dBm
• Up to +1 dBm RF
• Surface Mount
• Low Profile
• RoHS* Compliant version of the ELCM-2
• Tape and reel packagi ng available
Description
M/A-COM’s MAMXES0115 is a RoHS compliant de-
vice that is equivalent to the ELCM-2 mixer. This
device is a Low Cost, Broadband, high performance
Double Balanced Mixer designed for use in high
volume wireless applications. The device has been
optimised by careful selection of the Schottky Diode
and Balun Transformer for excellent performance.
The MAMXES0115 mixer is offered in an SM-89
surface mount package and is designed to be util-
ized in both standard reflow and high temperature
soldering reflow profiles.
Ordering Information
Part Number Package
MAMXES0115 Tape and Reel (900 pieces/ Reel)
Outline Drawing — SM-89
Electrical Specifications: @ +25°C, Z0 = 50 Ohms, LO = +7dBm
Parameter Test Conditions Frequency Units Min Typ Max
RF Frequency — 5 - 1000 MHz — — —
LO Frequency — 5 - 1000 MHz — — —
IF Frequency — DC - 1000 MHz — — —
Conversion Loss — 10 - 500 MHz
5 - 1000 MHz dB
dB —
— 6.5
7.0 8.0
9.5
Isolation (LO - RF) — 5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
dB
dB
40
20
18
50
40
25
—
—
—
Isolation (LO - IF) — 5 - 50 MHz
50 - 500 MHz
500 - 1000 MHz
dB
dB
dB
45
20
12
55
30
20
—
—
—
RF Input for 1 dB Com-
pression — — dBm — — +1