http://www.tracopower.com Page 3 of 6
AC/DC Power Modules
TML Series 5 to 30 Watt
Output Specifications
Voltage set accuracy 5 & 10 W models: ±2%
single output 15 & 30 W models: ±2%
dual output 15 & 30 W models: ±5%
triple output 15 W models: ±3%
triple output 30 W models: ±2% (output 1)
triple output 30 W models: ±5% (output 2 & 3)
Regulation – Input variation 0.3 % max.
– Load variation (10–100%)
single output models: 1.0 % max.
dual / triple output models: 5 % max.
Minimum load single output models: 5 %
dual output models: 3 % (each output)
triple output 15 W models: 10 % (main output only)
triple output 30 W models: 20 % (each output)
Ripple and noise (20 MHz bandwidth) – 3.3 & 5 VDC output models: <1.5 % of Vout
– other models: <1.0 % of Vout
Current limitation 120– 80 % fold back
Short circuit protection hiccup mode, indefinite (automatic recovery)
Maximum capacitive load 470–50’000 µF depending on model
General Specifications
Temperature ranges – Operating –25 °C to +60 °C
– Power derating above 50 °C 3.75 %/°C
– Storage (non operating) –40 °C to +85 °C
Temperature coefficient 0.02 %/°C
Efficiency 72–80 % (depending on model)
Humidity (non condensing) 95 % rel max.
Switching frequency 100 kHz typ. (pulse width modulation PWM)
Hold-up time 40 ms min. (Vin 115...230 VAC)
Isolation voltage – Input/Output 3‘000 VAC
Reliability /calculated MTBF (MIL-HDBK-217F at +25°C, ground benign) >660’000 h
EMI / RFI conducted EN 55022, class B, FCC part 15, level B
EMC compliance – Electrostatic discharge ESD IEC / EN 61000-4-2 4 kV / 8 kV
– RF field susceptibility IEC / EN 61000-4-3 3 V/m
– Electrical fast transients/bursts on mainsline IEC / EN 61000-4-4 1 kV
Safety class II (only 30 watt models) to IEC / EN 60536
Safety standards – UL/cUL 60950-1 UL 60950-1 and CSA C22.2 No. 60950-1-07
– IEC/EN 60950-1 re-aprroval June 2016 according: EN 60950-1:2006/A11:2009/A1:2010/
A12:2011/A2:2013
IEC 60950-1 (ed.2), Am 1&2
No re-approval according further amendments and safety-standard releases!
Safety approval – cUL/UL 60950-1 online certification File E188913 www.ul.com -> certifications
– IEC/EN 60950-1 CB test certificate
www.tracopower.com/products/tml-primary-certification.zip
(new in July 2016 as a last version)
Case material plastic resin + fiberglass
(flammability to UL 94-V0)
Environmental compliance – Reach www.tracopower.com/products/tml-reach.pdf
– RoHS RoHS directive 2011/65/EU
All specifications valid at nominal input voltage, full load and +25 °C after warm-up time unless otherwise stated.