The NLP150L series of 150 Watt ac-dc open-frame power supplies
are available with single, triple or quad outputs. The quad output
versions described in this datasheet are housed in a 3.8 x 7.8 x
1.26 inch package. All NLP150L series power supplies are
harmonic current corrected to meet the EN61000-3-2 standard,
and support current sharing. The power supplies are designed for
use in 1U shelves or boxes, and are primarily intended for
networking applications that have a heavy logic content, such as
access concentrators, midrange routers, LAN switches and shared
media hubs.
Embedded Power for
Business-Critical Continuity
NLP150L Series
Quad output
Special Features
• 90 VAC to 264 VAC
universal input range
• Provides low voltage
outputs (3.3 V)
• EN61000-3-2 compliant
• Overvoltage and
short circuit protection
• Power fail detection
• Current sharing
(on VA and VB)
• 3.8 x 7.8 x 1.26 inches
• UL, CSA and VDE
safety approvals and
CE-marked to LVD
• Compliance to EN55022-B
conducted noise standard
• Compliance to EN55022-A
radiated noise standard
• Meets all applicable and
relevant immunity standards
EN61000-4-2, -3, -4, -5 and -6
• Available RoHS compliant
• 2 year warranty
Total Power: 110-150W
Input Voltage: 90 - 264VAC
# of Outputs: Quad
Safety
VDE 0805/EN60950/IEC950
File No. 10401-3336-0162/47587
Licence No. 123897
UL1950 File No. E136005
CSA C22.2 No. 950
File No. LR41062C
Rev.02.20.07
NLP150L Series
1 of 5
Rev.02.20.07
NLP150L Series
2 of 5
Embedded Power for
Business-Critical Continuity
All specifications are typical at nominal input, full load at 25°C unless otherwise stated
Specifications
EMC CHARACTERISTICS (continued) (10)
Surge EN61000-4-5 Level 3
Fast transients EN61000-4-4 Level 3
Radiated immunity EN61000-4-3 Level 3
Conducted immunity EN61000-4-6 Level 3
GENERAL SPECIFICATIONS
Hold-up time 120 Vac @ 60 Hz 20 ms @ 150 W
Efficiency 120 Vac @ 150 W 73% typical
Isolation voltage Input/output 3000 Vac
Input/chassis 1500 Vac
Approvals and EN60950, VDE0805, IEC950
standards pending UL1950, CSA C22.2 No. 950
Weight 540 g (19 oz)
MTBF (@ 25°C) MIL-HDBK-217F 350,000 hours min.
Bellcore 800,000 hours min.
ENVIRONMENTAL SPECIFICATIONS (8)
Thermal performance Operating ambient, 0 °C to +50 °C
(See derating curve)
Non-operating -40 °C to +85 °C
50 °C to 70 °C ambient, Derate to
convection cooled 50% load
0 °C to 50 °C ambient, 110 W
convection cooled
0 °C to 50 °C ambient, 150 W
300 LFM forced air
Peak (0 °C to +50 °C)
Relative humidity Non-condensing 5% to 95% RH
Altitude Operating 10,000 feet max.
Non-operating 30,000 feet max.
Vibration (See Note 6) 5-500 Hz 2.4 G rms peak
Shock per MIL-STD-810E 516.4 Part IV
OUTPUT SPECIFICATIONS
Total regulation Main output ±2.0%
(Line and load) Auxiliary outputs ±5.0%
Rise time At turn-on 1.5 s, max.
Transient response Main output 5.0% or 250 mV
75% to 100% max. dev., 1 ms max.
step at 0.1 A/μs recovery to 1%
Temperature coefficient ±0.02%/°C
Overvoltage protection Main outputs 125%, ±10%
Short circuit protection Cyclic operation Continuous
Minimum output current Single and multiple See table
INPUT SPECIFICATIONS
Input voltage range Universal input 90-264 Vac
Input frequency range 47-63 Hz
Input surge current 264 Vac (cold start) 40 A max.
Safety ground 264 Vac, 60Hz 0.99 mA
leakage current
Input current 120 Vac @ 150 W 1.95 A rms
230 Vac @ 150 W 1.10 A rms
Input fuse UL/IEC127 F3.15A H, 250 Vac
EMC CHARACTERISTICS (10)
Conducted emissions EN55022, FCC part 15 Level B
Radiated emissions EN55022, FCC part 15 Level A
Harmonic current EN61000-3-2 Compliant
emission correction
ESD air EN61000-4-2 Level 3
ESD contact EN61000-4-2 Level 3
Rev.02.20.07
NLP150L Series
3 of 5
Embedded Power for
Business-Critical Continuity
Specifications Contd.
Notes
1Free air convection.
Multiple output units: maximum continuous output power not to exceed 110
W and the output current not to exceed: IA+IB+2(IC+ID)≤23 A.
2300 LFM forced air cooling from the longer side.
Multiple output units: maximum continuous output power not to exceed 150
W and the output current not to exceed: IA+IB+2(IC+ID)≤32 A.
3Peak output current lasting less than 30 seconds with duty cycle less than 5%.
During peak loading, output voltage may exceed total regulation limits.
4Figure is peak-to-peak for room temperature rating. Output noise
measurements are made across a 20 MHz bandwidth using a 6 inch twisted
pair, terminated with a 10 μF electrolytic capacitor and a 0.1 μF ceramic
capacitor.
5Minimum load required for correct start-up and operation on single outputs
and on main output of multiple versions. Failure to observe minimum load on
main output will not allow the supply to start-up correctly. Some electronic test
loads have a large delay time before they start drawing current even though the
voltage from the supply is present. During this time delay, there is no load on
the output and as a result, the supply may not be able to start-up properly and
maintain its correct output voltage. In these instances, a dummy resistive load
across the output may be necessary to load the output of the supply until the
test load can function correctly and draw the intended minimum load.
Minimum load required on auxiliary outputs to maintain regulation.
6Three orthogonal axes, random vibration 10 minutes for each axes, 2.4 G rms 5
Hz to 500 Hz.
7For optimum reliability no part of the heatsink should exceed 110 °C and no
semi-conductor case temperature should exceed 120 °C.
8CAUTION: Allow a minimum of 1 second after disconnecting line power when
making thermal measurements.
9This product is only for inclusion by professional installers within other
equipment and must not be operated as a stand alone product.
10 Conducted EMI specifications reference measurements made with the power
supply mounted on a grounded metal sheet extending 1 inch beyond each
edge, using an unshielded cable. No external filtering required during
conducted emissions testing but some applications may require additional
filtering to achieve system compliance. Compliance with Radiated EMI
specifications may require mounting in a suitable enclosure.
11 All models require a minimum mounting stand-off of 6.35 mm (0.25 inches) in
the end use product.
12 The ‘Y’ suffix indicates that these parts are non Pb-free (RoHS 5/6) compliant.
RoHS 6/6 (Pb-free) compliant versions are also available by replacing the suffix
‘Y’ with the suffix ‘J’ e.g. NLP150L-96Q5366J.
13 NOTICE: Some models do not support all options. Please contact your local
Artesyn representative or use the on-line model number search tool at
http://www.artesyn.com/powergroup/products.htm to find a suitable
alternative.
DERATING CURVE
Output Power (Watts)
0°C 10°C 20°C 30°C 40°C 50°C 60°C 70°C
55W
110W
150W 300 LFM FORCED
AIR COOLING
75W
NATURAL
CONVECTION
COOLING
OUTPUT OUTPUT CURRENT RIPPLE (4) TOTAL MODEL
VOLTAGE MIN (5) MAX (1) 300 LFM (2) REGULATION NUMBERS (12,13)
5.1 V (VA) 1.5 A 20 A 30 A 50 mV ±2.0% NLP150L-96Q5366Y
+3.3 V (VB) 0.5 A 10 A 15 A 50 mV ±2.0%
+12 V (VC) 0 A 2 A 3 A 120 mV ±5.0%
12 V, iso (VD) 0 A 0.65 A 1 A 120 mV ±5.0%
Rev.02.20.07
NLP150L Series
4 of 5
Embedded Power for
Business-Critical Continuity
Mechanical Notes
AAll dimensions are in inches (mm).
7.800 (198.12)
J2
J1
J3 1
2
1
2
1
2
1
1
5
4
1
2
J5
JCS
JRM3
JRM5
J6
F1 T1 (REF.)
2
1
0.225 (5.72)
3.800 (96.52)
3.350 (85.09)
0.220 (5.59)
ALL DIMENSIONS IN INCHES (MM)
MAXIMUM COMPONENT HEIGHT 1.26 (32.00)
7.350 (186.69)
3.755 (95.38)
2.385 (60.58)
0.000 (0.00)
0.000 (0.00) Ø0.156 (Ø3.96)
(5 PLS)
Recommended direction for
forced air relative to power
supply orientation shown
below.
1 Best.
2 Good.
3 Not recommended.
4 Not recommended.
1
34
2
JCS PIN CONNECTIONS
Pin 1 Load A Current Sharing
Pin 2 Load B Current Sharing
CONNECTOR AND MATING CONNECTOR TYPES
CONNECTOR TYPE MATING CONNECTOR TYPE
J1 Molex 26-60-4030 or equivalent Molex 09-50-3031 or equivalent with Molex 08-50-0105 or equivalent crimp
terminals
J2 Male 0.250 quick disconnect Molex 22-01-AA-5261, AA22-01 or equivalent
J3 Molex 26-60-4040 or equivalent Molex 09-50-3041 or equivalent with Molex 2478 phosphor bronze
or equivalent crimp terminals
J5 Beau Interconnect 70505-C-50 or 70 5 05-C50
equivalent
J6 Molex 22-23-3021 or equivalent Molex 22-01-2021 and contact 08-50-0113 terminals or equivalent
JRM3, JRM5 Leoco 2421P02H000 or equivalent Leoco 2420S02000 and contact 2453TPB00V1
& JCS
J5 PIN CONNECTIONS
Pin 1 VAPositive
Pin 2 VAPositive
Pin 3 Main RTN
Pin 4 Main RTN
Pin 5 VBPositive
J1 PIN CONNECTIONS
Pin 1 Neutral
Pin 2 Void
Pin 3 Line
JRM3 PIN CONNECTIONS
Pin 1 VBSense +
Pin 2 VBSense -
JRM5 PIN CONNECTIONS
Pin 1 VASense +
Pin 2 VASense -
J6 PIN CONNECTIONS
Pin 1 Signal
Pin 2 RTN
Note:VD is a floating output.
It can be configured as positibe or negative
J3 PIN CONNECTIONS
Pin 1 VDPositive
Pin 2 VDRTN
Pin 3 VCPositive
Pin 4 VCRTN
Embedded Power for
Business-Critical Continuity
Rev.02.20.07
NLP150L Series
5 of 5
Emerson Network Power and the Emerson
Network Power logo are trademarks and
service marks of Emerson Electric Co.
©2007 Emerson Electric Co.
Emerson Network Power.
The global leader in enabling
business-critical continuity.
EmersonNetworkPower. com
AC Power
Connectivity
DC Power
Embedded Power
Inbound Power
Integrated Cabinet Solutions
Outside Plant
Precision Cooling
Site Monitoring and Services
Americas
5810 Van Allen Way
Carlsbad, CA 92008
USA
Telephone: +1 760 930 4600
Facsimile: +1 760 930 0698
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
Telephone: +44 (0) 1384 842 211
Facsimile: +44 (0) 1384 843 355
Asia (HK)
16th - 17th Floors, Lu Plaza
2 Wing Yip Street, Kwun Tong
Kowloon, Hong Kong
Telephone: +852 2176 3333
Facsimile: +852 2176 3888
For global contact, visit:
www.powerconversion.com
technicalsupport@powerconversion.com
While every precaution has been taken to ensure
accuracy and completeness in this literature, Emerson
Network Power assumes no responsibility, and disclaims
all liability for damages resulting from use of this
information or for any errors or omissions.