Manual Switches PB Series
Pushbutton Switches
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 125
FEATURES
1
Compact size
1
Up to 4-poles
1
Sealed versions
TOUCH FEEDBACK SWITCHES
SHORT TRAVEL SWITCHES
PANEL SEALED SWITCHES
ORDER GUIDE
Momentary and alternate action switches.
No. of SPDT Circuits
2244
Button Mom. Alt. Mom. Alt.
Color Action Action Action Action
Black 2PB11-T2 82PB19-T2 84PB19-T2
2PB732-T2 4PB714-T2
(M8805/23-001) (M8805/23-003)
Red 2PB12-T2 82PB21-T2
2PB717-T2 4PB717-T2
(M8805/23-002) (M8805/23-004)
Green 2PB273-T2 82PB22-T2
ORDER GUIDE
Momentary action switches.
Button No. of SPDT Circuits
Color 2 3
Black 2PB7 3PB7
Theseswitchesresemblethetouch-feed-
back design, but have a flexible leaf ac-
tuatorforloweroperatingforceandshort-
er button travel.
Anelastomer sealisbondedbetween ac-
tuating plunger and button collar. An O-
ringsealsthebuttonassemblytothepan-
el front.
Two-piece design enables button to be
mounted separately. After switch unit is
wired, it snaps into place from behind
panel.
ORDER GUIDE
Momentary action switches.
No. of SPDT CircuitsButton Collar
Color Type 12
Black Hex 1PB4 2PB4
Black Round 1PB42
Red Round 1PB43 2PB43
ELECTRICAL RATINGS
(Except15PB and 700PB)
30 VDC: 5 amps, res., sea level or 50,000
ft.; 3 amps, ind., sea level; 2.5 amps
ind., 50,000 ft; 24 amps, max. inrush.
UL and CSA rating for basic switches: 5
amps,125 or 250 VAC.
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches PB Series
Pushbutton Switches
126 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
WATERTIGHT SWITCH ORDER GUIDE
Momentary action switches.
Has knurled chrome-finished facenut.
Button No. of SPDT Circuits
Color 2
Black 2PB901-T2
Facenut-to-panel, button-to-facenut, and
bushing-to-facenut, sealing helps pre-
vent entry of water from behind panel, up
and over bushing wall. Switch units pot-
ted in corrosion resistant metal enclo-
sure. Meets submergence requirements
of MIL-STD-108 (up to10 PSI water pres-
sure for one hour).
HERMETICALLY SEALED
SWITCHES These pushbuttons are equipped with
HM hermetically sealed switch units,
which have metal-to-metal fusion around
the cover, actuator base, and mounting
holes. Terminals are sealed glass-to-
metal.
Vapor-proof construction enables use in
damp locations without condensation on
contacts. External parts corrosion resist-
ant per MIL-S-8805. Meets explosion-
proof requirements of MIL-S-8805.
ORDER GUIDE
Momentary action switches.
No. of SPDT Circuits
24
Button
Color
Black 702PB1 704PB1
MINIATURE SIZE SWITCHES
1PB5 15PB2
ORDER GUIDE
Momentary action switches.
No. of SPDT Circuits
Button 12
Steel* 1PB5
White Plastic 15PB2
* Steel button enables use under hinged plates or paddle levers, in addition to manual operation.
ELECTRICAL RATINGS 700PB
and 15PB
700PB (With hermetically sealed switch
units):
28 VDC and 115 VAC, 400 HZ: 3 amps,
ind., 5 amps, res.
15PB:
30 VDC and 115 VAC: 2 amps, ind., 5
amps. res.;1.0 amp, lamp load.
1PB5
250 VAC: 5 amps.
30VDC: 5amps,res.,sealevelor50,000
ft.; 3 amps, ind., sea level; 2.5 amps ind.,
50,000 ft.; 24 amps, max. inrush.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches PB Series
Pushbutton Switches
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 127
MOUNTING DIMENSIONS (For reference only)
Touch Feedback Switches Panel Sealed Switches
2-Pole 4-Pole
Dim.
‘‘
A’’ Mom. 16,8/.66 30,0/1.18
(max.) Alt. Act. 17,3/.68 30,5/1.20
Dim.
‘‘
B’’ Mom. 26,7/1.05 26,7/1.05
Alt. Act. 33,0/1.34 33,0/1.34
Short Travel Switches
2-Pole 3-Pole
Dim.
‘‘
A’’ (max.) 17,0/.67 23,8/.94
1-Pole 2-Pole
Dim.
‘‘
A’’ (max.) 11,7/.46 17,0/.67
Key: 0,0 Jmm
0.00 Jinches
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches PB Series
Pushbutton Switches
128 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
MOUNTING DIMENSIONS (For reference only)
Watertight Switch Miniature Size Switches
Hermetically Sealed Switches
Mounting hardware includes:
hexnut, lockwasher, and
keying washer.
2-Pole 4-Pole
Dim.
‘‘
A’’ (max.) 16,8/.66 30,0/1.18 Key: 0,0 Jmm
0.00 Jinches
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 111
FEATURES
1
Easy-to-assemble modules provide
thousands of display/control
combinations
1
Up to 4 incandescent lamps
1
1, 2, 3, or 4-section display
1
Transmitted or projected color
1
Integral hold-in coil option provides
remote released contacts. Pull-in coils
(flange mount only) enable remote
actuation
1
Switch guard accessory.
CHANGE LAMPS OR FILTERS
FROM PANEL FRONT
Without tool. Remove display screen/
lampholder assembly from 2C200 oper-
ator-indicator (or 2F200 indicator). Unit is
keyed to maintain proper orientation
when replacing. Use only flange base
T-134lamps with 2C200 and 2F200 de-
vices.
LAMPS AND FILTERS
Orderlampsandfiltersforprojectedcolor
from page117.
BARRIER MOUNT
Display screen
(page 115) Housing
(next page)
Mounting barrier
(next page)
Switch unit
(page 114)
Mountingbarriersattachtoeitherthelong
or short sides of the housing. They have
spring clips which grip the panel. Mount-
ingbarriersalsoseparatedisplayscreens
to protect against inadvertent operation.
Multipleunits canbeattachedtogether in
a strip and snapped into a panel slot; or
they can be mounted individually.
FLANGE MOUNT
Display screen
(page 115)
Housing
(page 113)
Switch
unit
(page 114)
Flange mount units have mounting clips
ready-attached to the housing. They can
be individually installed or replaced; and
enableuse ofan overlaypanel,ifdesired.
Groupings can be separated by optional
spacing barriers.
MODULES ASSEMBLE EASILY
All modules are ordered as separate
items which snap together for easy as-
sembly.
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbuttons Switches and Indicators
112 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
Barriers on long sides
Barriers on short sides
BARRIER MOUNT MODULES
Barrier mount assemblies are identical in
panel appearance. Operator-indicator
housings have spring clips for attaching
switch modules. This feature is not pro-
vided with indicator housings.
Barriers are necessary for mounting.
They can be specified for attachment to
the long or short side of the housing, as
stated in the order guides.
BARRIER MOUNT HOUSING ORDER GUIDE
See ‘‘Application Data’’ for typical bailing circuits for coil-equipped modules.
Tool Not RequiredBarriers
Attach On: No. of
Lamp Sockets Operator-Indicator Indicator Only
Long Sides
of Housing 2 (A & C) 2C207
4 (A-D) 2C209
Short Sides
of Housing 2 (A & C) 2C201
4 (A-D) 2C203 2F203
MOUNTING BARRIER ORDER GUIDE
For strip mounting, specify one more barrier than the number of units in the group.
Catalog ListingsMounting Barrier For Panel
Type Thickness Gray Black
Attach to
Long Sides .06-.19 in. (1,52-4,83 mm) 2B2 2B4
Attach to
Short Sides .06-.19 in. (1,52-4,83 mm) 2B1 2B3
Note: Panels .19 in. (1,52 mm) thick require the .06-.19 in. (1,52-4,83 mm) type barriers.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 113
Flanges on long sides
FLANGE MOUNT MODULES
Flange mount assemblies are identical in
panel appearance. Operator-indicator
housings have spring clips for switch
modules attachment (not provided with
indicator housings).
Barriers are not required, since the panel
mounting clips are ready-attached to
flange sides of the housings. However,
spacing barriers can be used for color-
coding. They also aid in preventing inad-
vertentoperation of two screens with one
push.
Mounting dimensions on page120.
FLANGE MOUNT HOUSING ORDER GUIDE
See ‘‘Application Data’’ for typical bailing circuits for coil-equipped modules.
Tool Not Required
Flanges On: No. of Lamp
Sockets Operator-
Indicator Indicator Only
Long Sides of
Housing 2 (A & C) 2C204
4 (A-D) 2C206 2F206
SPACING BARRIER ORDER GUIDE
For .06-31in. (1,5-7,9 mm) thick panels.
Catalog ListingsSpacing Barrier
Type Gray Black
For Long Flange Housing 2B9 2B18
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
114 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
SWITCH MODULES Interchangeable type 2D switch modules
attachtospringclipsonthebottomofop-
erator-indicatorhousings.Thereisawide
selection of circuitry, electrical ratings,
operating actions and terminations.
For mounting dimensions, see page121.
ELECTRICAL RATING
Silver contacts:
30VDC:5ampsres.sealevelor50,000ft,
3ampsind.sealevel,2.5amps50,000ft.
Max. inrush, 24 amps.
UL and CSA rating for basic switch: 5
amps,125 or 250 VAC.
Gold contacts:
30VDC:0.5ampind.,1ampres.,sealevel
and 50,000 ft. Max. inrush, 2 amps.
SM SUBMINIATURE MULTI-SPDT SWITCH MODULES
Momentary action Alternate action
SM switch modules offer a choice of two
momentary action styles, one with a pro-
nounced touch-feedback, the other with
low operating force for rapid repeat ac-
tuation. Also available with alternate-
action and combination momentary/
alternate action modules. Extra length
turret solder terminals.
SM SWITCH MODULE ORDER GUIDE
Momentary Action Alternate Action
Touch-Feedback Type Low Force TypeNo. of
SPDT Circuits Silver Contacts Silver Contacts
1 2D100 2D118
2 2D2 2D26
4 2D9 2D33
V3 COMPACT SPDT/DPDT SWITCH MODULES
V3 switch modules have screw terminals
with lockwashers. Quick-connect termi-
nals(notshown)arealsoavailable.When
used with short-flange operator indica-
tors, add spacing barriers to prevent
interference.
ELECTRICAL RATING
30 VDC: 10 amps ind.* sea level, 6 amps
ind.,*50,000 ft.Motorload,6amps.**UL
andCSAratingforbasicswitch:10amps,
13Hp, 125 or 250 VAC; 12amp, 125 VDC;
14amp, 250 VDC.
* Inductive currents in accordance with AN3179.
** Motor load rating based on starting current.
V3 SWITCH MODULE ORDER GUIDE
No. of SPDT
Circuits Momentary Action
1 2D70
2 2D72
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 115
ONE-PIECE DISPLAY
SCREEN OPTIONS
Single-section
These translucent solid color display
screens are single-section/one piece
construction
SINGLE-SECTION/
ONE-PIECE SCREENS ORDER GUIDE
Colors Standard
Red 2A1
Yellow 2A2
Green 2A3
White 2A5
THREE-PIECE DISPLAY
SCREEN OPTIONS
Single-section
These screens have transparent colored
or colorless caps, transparent colorless
legend inserts and translucent colored
bases.
SINGLE-SECTION/THREE-PIECE
SCREENS ORDER GUIDE
Colorless
Color Caps
Red 2A81
Yellow 2A82
Green 2A85
White 2A70
Amber 2A114
NOTE:
Add –L to catalog listing if button is to be
legended.
Silicone rubber baffles prevent light spillage
from one section to another. Screen caps and
legend inserts are transparent colorless. Bases
are translucent colored.
Formore information on2,3,and4-section dis-
play screens, contact the MICRO SWITCH Ap-
plication Center.
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
116 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 117
LEGEND INFORMATION
Honeywell MICRO SWITCH Division pro-
vides legend service on the inserts sup-
plied with three-piece screens only. To
specify your needs, add -Lto the catalog
listings (example: 2A81-L) and use Leg-
end Order Sheet (Form FO-62308),
shown on facing page. Reproduce it on
your office copier.
Onanyone insert,onlyonesize oftypeis
providedineitherblackorwhite.Afterleg-
ending,theinsertisassembledtothedis-
play screen. The type face used is ‘‘Mod-
ified Gothic’’.
LAMPS
T-134incandescent lamps are available
from MICRO SWITCH in 28 volt versions.
Use of neon lamps is not recommended.
Light output is approximately 30% of an
incandescent lamp. Also, a neon lamp
will not illuminate blue or green filters or
display screens due to the absence of
these colors from the neon light spec-
trum.
LAMP POLICY
The 28 volt lamps are offered as a conve-
nience to customers. Honeywell MICRO
SWITCH Division does not extend any
warranty as to such lamps, and cannot
guarantee to provide lamps from specific
manufacturers. Any technical or quality
questions regarding such lamps should
be directed to the lamp manufacturer.
COLOR FILTERS FOR PROJECTED
COLOR
Projected color is achieved by using
white buttons and color filters over clear
lamps. When lamps are lighted, white
button takes on color projected by the fil-
ters.
Filters used with type 2C200 and 2F200
housings (no-tool relamping) slip over
lamp sockets in lampholder.
MIL-S-22885 ASSEMBLED DEVICES
Pushbutton switches and indicators can
be ordered as assembled devices from a
single MIL-S-22885 part number. Desig-
nated Series 2W, they are available for
flange mounting and have the no-tool re-
lamping feature. For ordering informa-
tion, refer to MICRO SWITCH Catalog 80.
SCREEN/LEGEND COLORS
The chart below shows recommended
display screen and legend color combi-
nations for optimum legibility.
Legend Lettering
Screen
Color Black White
Red x
Green x
Yellow x
Amber x x
White x
LAMP ORDER GUIDE
Rating Life/Voltage†
Catalog Base Type Life in Expected
Listing Style No. Volts Amps Hours Volts Life (Hrs.)
2E1 Flange 327 28 .040 1000 24.0 7,500
26.0 2,800
30.0 400
These are experimental continuous life test results supplied by a lamp manufacturer for reference only. In-
termittent operation may reduce these figures as much as 50%. Ratings are based on median values of cur-
rent and life.
Wattage should not exceed 2.4 watts (2 lamps) per switch, for continuous illumination.
FILTER ORDER GUIDE
Filter Style Red Green Amber White*
For Type 2C200 and 2G12 2G14 2G16 2G17
2F200 Housings
* Has blue tint to compensate for high yellow content of incandescent lamps at low voltages.
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
118 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
SWITCH GUARD ACCESSORY
Ahinged coveronthe switchguardhelps
avoidinadvertentoperationofthedisplay
screen. It is installed in place of the trans-
parent slide-on cap furnished with three-
piece screen. Note: When used with pull-
in coil devices, specify the 2C200 oper-
ator-indicator housings which have the
no-tool relamping feature.
Barrier mount assembly with guard in-
stalled. (Can also be used with all flange
mount units.)
Guard requires a ‘‘lift-to-push’’ response
to operate switch normally.
Order Catalog Listing 2H20
Key: 0,0 =mm
0.00 =inches
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 119
MOUNTING DIMENSIONS (For reference only)
Long barrier operator-indicators Short barrier operator-indicators
Short barrier indicators Long barrier indicators Mounting barriers
Short Long
0,0 =mm
Key: 0.00 =inches.
A Panel Thickness
1,5/.06 1,5-4,81/.06-.19
4,6/.18 4,8-7,9/.19-.31
Length Of Panel Cutout*
Number of Units
Type of Indicator or
Operator-Indicator 1 2 3 4 5 6 7
Short mm 36,09 68,00 99,87 131,72 163,60 195,48 227,36
Barrier in. 1.421 2.677 3.932 5.186 6.441 7.696 8.951
Long mm 30,00 55,78 81,58 106,34 133,12 159,90 184,68
Barrier in. 1.181 2.196 3.212 4.226 5.241 6.256 7.271
*Nominal dimensions, ±0,25 mm/0.10 in. (In 5% of
thecases,thecutoutwillbeundersizedforthebuild-
upofassembled unitsandwill requireenlargement.
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
120 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
MOUNTING DIMENSIONS (For reference only)
Long flange
operator-indicators
Long flange indicators Spacing barriers
Short Long
0,0 =mm
Key: 0.00 =inches.
Length Of Panel Cutout*
Add 4,19 mm/.165 in. to length for each optional spacing barrier used.
Number of Units
Type of Indicator or
Operator-Indicator 1 2 3 4 5 6 7
Long mm 27,94 55,75 83,57 111,36 139,17 166,98 194,77
Flange in. 1.1 2.195 3.290 4.384 5.479 6.574 7.668
*Nominal dimensions, ±0,25 mm/0.10 in. (In 5% of
thecases,thecutoutwillbeundersizedforthebuild-
upofassembled unitsandwill requireenlargement.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 2
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 121
MOUNTING DIMENSIONS (For reference only)
SM Switch Modules
V3 Switch Modules
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches DM Series
Pushbutton Switches
122 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
FEATURES
1
Attractive, rugged snap-in panel
mount design easy installation.
1
Snap-on or integral pushbuttons.
1
Choice of momentary, alternate,
push-pull and pull-to-cheat operation.
1
Quick-connect terminals.
1
Expected mechanical life:1million
operations, 95% survival.
1
Temperature range:
–35°to +180°F (–37°to 82°C)
1
UL recognized, (E12252) CSA
certified (LR4442).
Three different styles of snap-on buttons
canbe used with the DM switches shown
above.There isachoiceofmomentaryor
alternate-action, and single or double-
pole circuitry.
ELECTRICAL RATING
UL and CSA rating:10 amps,1/2 Hp,125,
250 or 277 VAC.
SWITCHES WITH SNAP-ON BUTTONS
With button
‘‘
A’’ With button
‘‘
B’’
SPDT DPDT
SWITCH ORDER GUIDE
Switches have gray faceplates. Buttons
are not included.
Momentary
Circuitry Action
SPDT 3DM1
DPDT 4DM1
Order buttons separately or ready-
installedonswitchesfromtheorderguide
below.
SPDT
DPDT
SWITCH/BUTTON ORDER GUIDE
Switches have gray faceplates.
Momentary Action Alternate Action
Button
Style Button
Color Button
Only 3DM1 (SPDT)
and Button 4DM1 (DPDT)
and Button 2003DM1 (SPDT)
and Button
A
Black 31PA1 13DM1-A1 14DM1-A1
Red 13DM1-A2 14DM1-A2
B
Black 31PA3 13DM1-B1 14DM1-B1
Red 31PA4 13DM1-B2 2013DM1-B2
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
104 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
Bezel on all sides Barriers on short sides Barriers on long sides
Barrier on one short side Barriers on one long side
FEATURES
1
Provides distinctive color display
whether lighted or unlighted.
1
Convenient front panel mounting and
relamping, without tools.
1
Matching indicators.
1
Locked button option discourages
tampering.
1
Choice of transmitted color, projected
color, or dead front display.
1
UL recognized, CSA certified.
MOUNTING
Snap-in mounting. Switch or indicator is
easily inserted into the cutout. Mounting
clips grip the panel. No tools are needed.
Housings with a full bezel can be front
panel or sub-panel mounted, individually
or in strips.
Barrier type housings are normally
mountedtop-of-panelinstrips,butcanal-
so be individually mounted. Barriers can
be on either the short or long housing
sides.
The drawing shows how housings with a
barrier on one side are used in a strip of
two or more units. The first has a barrier
on two sides, while all other units have a
barrierononeside,andbuttagainsteach
other.
Barriers on Barriers on
both sides. one side.
Incandescent Housing
Button Lamp
RELAMPING
1. Lamps and legends can be changed
from panel front. When button is re-
moved, lamp is extracted from its
socket and retained in button.
2. Easeoflampreplacement.Afterthein-
operative lamp is automatically re-
movedwiththebutton,thenewlampis
inserted without the use of tools.
ELECTRICAL RATINGS
5-amp silver contacts
5 amps res., 3 amps ind., 30 VDC.
UL code L-4: 5 amps, 250 VAC
10-amp silver contacts
UL code L-285; 10 amps, 16Hp, 125
or 250 VAC.
Gold contacts
1 amp res., 0.5 amp, ind., 30 VDC
UL code L-22: 1 amp, 125 VAC
Gold alloy contacts
0.1 amp, res., 30 VDC;
1 amp, 125 VAC.
LOCKED BUTTON OPTION
Series 4 can be furnished with a locked
button option for use in areas accessible
to the public, where tampering and van-
dalism are problems. The housing has a
special mounting clip with built-in button
retainer. This mounting clip must be re-
moved from behind panel to allow button
removal.Buttonmovement duringswitch
operation is unaffected by locked button
feature.(Theseunits cannotberelamped
from front of panel.)
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 105
SWITCH HOUSING ORDER GUIDE
Order buttons separately from page116.
4A11B AA 11
Switching Element
Terminals
Switch Housing Style Incandescent
(Black) Electrical Data Action .110 QC PC* Illumination
11
No lamp,
has lamp socket for T-314
wedge base lamps.
21
#161 12-volt
T-314lamp.
31
#656 or 152
28-volt
T-314lamp
91
Unlighted,
no lamp socket.
4A11B
Bezel: all sides
Mtg. clips: long sides
4A12B
Bezel: all sides
Mtg. clips: short sides
4A31B
Barriers: long sides
Mtg. clips: long sides
4A32B
Barriers: long sides
Mtg. clips: short sides
4A33B
Barrier: one long side
Mtg. clips: long sides
4A34B
Barrier: one long side
Mtg. clips: short sides
4A21B
Barriers: short sides
Mtg. clips: long sides
4A22B
Barriers: short sides
Mtg. clips: short sides
4A23B
Barrier: one short side
Mtg. clips: long sides
4A24B
Barrier: one short side
Mtg. clips: short sides
With Housing Provision
for Locked Button
4A13B
Bezel: all sides
Mtg. clips: long sides
4A25B
Barriers: short sides
Mtg. clips: long sides
4A26B
Barrier: one short side
Mtg. clips: long sides
4A35
Barriers: long sides
Mtg. clips: long sides
4A36
Barrier: one long side
Mtg. clips: long sides
1-Pole
(SPDT),
5 a. silver contacts
Momentary
Alt. Action
AA
BA
AD
BD
2-Pole
(DPDT),
5 a. silver contacts
Momentary
Alt. Action
EA
FA
ED
FD
1-Pole
(SPDT),
gold contacts
Momentary
Alt. Action
CA
DA
CD
CD
2-Pole
(DPDT),
gold contacts
Momentary
Alt. Action
GA
HA
GD
HD
1-Pole
(SPDT),
10 a. silver contacts
Momentary
Alt. Action
LA
MA
2-Pole
(DPDT),
10 a. silver contacts
Momentary
Alt. Action
NA
PA
1-Pole
(SPDT),
gold alloy contacts
Momentary
Alt. Action
QA
RA
2-Pole
(DPDT),
gold alloy contacts
Momentary
Alt. Action
TA
VA
Example:
4A11BAA11
Black switch housing with a bezel on all
sides, mounting clips on long sides, 1-
polemomentary-action5-amp silvercon-
tacts, 110Nquick-connect/solder termi-
nals, and a T-314lamp socket.
MOUNTING CLIP ORIENTATION
Mounting clips on the long sides of the
housing are specified when individually
mounted or when the long sides of strip
mounting housings parallel the long
sides of the panel cutout slot. The most
secure mounting is achieved when the
mounting clips are on the long sides.
Mounting clips on the short sides of the
housingarespecifiedwhenshortsidesof
strip mounted housings parallel the long
sides of the panel cutout slot.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
106 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
HOW TO ORDER ASSEMBLED
SWITCHES OR INDICATORS
With lamp assembled:
To order a lamp assembled, enter the ap-
propriate ILLUMINATION Code Number,
as shown in the lamp chart on the next
page. Example: 4A11BBA12 is furnished
with a 6-volt lamp installed.
With button assembled:
To order a button assembled in the hous-
ing, add the code letters for BUTTON
TYPE, DISPLAY COLOR, and LEGEND
(page60)tothehousinglisting.Example:
4A11BBA12AGNisfurnished withagreen
transmitted-color unlegended button as-
sembled in the housing (and with a 6-volt
lamp installed).
INDICATOR ORDER GUIDE
Order buttons separately from page107.
4C11B 11
Indicator Housing Style (Black)
Terminals Incandescent
Description .110 Q.C. P.C. Illumination
11
No lamp, has
lamp socket for T-314
wedge base lamps.
21
#161 12-volt
T-314lamp.
31
#656 or 152
28-volt
T-314lamp
91
Unlighted,
no lamp socket.
Bezel: all sides 4C11B 4D11B
Mtg. clips: long sides
Bezel: all sides 4C12B 4D12B
Barriers: short sides
Barriers: short sides 4C21B 4D21B
Mtg. clips: long sides
Barriers: short sides 4C22B 4D22B
Mtg. clips: short sides
Barrier: one short side 4C23B 4D23B
Mtg. clips: long sides
Barrier: one short side 4C24B 4D24B
Mtg. clips: short sides
Barriers: long sides 4C31B 4D31B
Mtg. clips: long sides
Barriers: long sides 4C32B 4D32B
Mtg. clips: short sides
Barrier: one long side 4C33B 4D33B
Mtg. clips: long sides
Barrier: one long side 4C34B 4D34B
Mtg. clips: short sides
With Housing Provision
for Locked Button
Bezel: all sides 4C13B 4D13B
Mtg. clips: long sides
Barriers: short side 4C25B 4D25B
Mtg. clips: long sides
Barrier: one short side 4C26B 4D26B
Mtg. clips: long sides
Barriers: long sides 4C35B 4D35B
Mtg. clips: long sides
Barrier: one long side 4C36B 4D36B
Mtg. clips: long sides
Example:
4C11B11
Blackindicatorhousingwithabezelonall
sides, mounting clips on long sides,110N
quick-connect/solder terminals, and a
socket for a T-314lamp.
MOUNTING CLIP ORIENTATION
Mounting clips on the long sides of the
housing are specified when individually
mounted or when the long sides of strip
mountedhousingsparallelthelongsides
of the panel cutout slot. The most secure
mountingis achievedwhen themounting
clips are on the long sides.
Mounting clips on the short sides of the
housingarespecifiedwhenshortsidesof
strip mounted housings parallel the long
sides of the panel cutout slot.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 107
BUTTON ORDER GUIDE
4B1 A G N
Button Legend
With Button Display (Legend Order Sheet must accompany
Metal Shell* Type Color all orders for legended buttons)
A
Transmitted color.
5 sides lighted.
1-piece translucent button.
B
Projected color
5 sides lighted.
Translucent white button
& color insert.
C
Dead front,
5 sides lighted.
Transparent black button
& translucent color insert
D
Dead front,
Only face lighted.
Transparent black button
& translucent color insert.
E
Transmitted color.
5 sides lighted.
Transparent colorless
button &
translucent color insert.
U, N, or K type only.
F
Transmitted color.
Only face lighted.
Transparent colorless
button & color insert.
U, N or K type only.
G
Same as type
‘‘
A’’
except .250Nhigher
B
Std. Blue
G
Std. Green
R
Std. Red
S
Transparent Black
(Unlighted
applications only)
Y
Std. Yellow
W
Std. White
(Do not use with
Type B button)
A
Std. Amber
(For use with Type A
or G button only)
U
No legend, button
(incl. insert) unassembled.
(For customer who does own legending.)
Use with any button except 4B1A—
N
No legend, button assembled.
(For applications not requiring legends.)
Use with any button.
L
Legend on button only, button assembled.
(For customer who prefers to have
MICRO SWITCH provide legending.)
Use with any button except E and F.
K
Legend on insert only, button assembled.
(for C, D, E and F button types.)
J
Legends on both
button and insert,
button assembled.
UsewithC&Dbutton types
4B2
Both button and metal
shell provided.
Button With
Metal Shell,
With
Provision for
Locked Button*
4B3
Both button and metal
shell provided.
Button
Without
Metal Shell
4B1
Button only.
(without metal shell).
For replacement
purposes only.
*To be ordered with switch. LEGENDING
Pad printed legends
Use Legend Order Sheet FO-63039 (see
page110)tospecifypad printed legends.
Reproduce it on your office copier. Leg-
endsareoversprayedformaximumdura-
bility.
Film legends
Film legends are not supplied by MICRO
SWITCH. However, this service is readily
available from commercial sources or
may be provided through your in-house
capabilities. The film should be polyester
towithstandlampheatandmustbepreci-
sion cut, per the dimensions shown on
thenextpage,toinsureproperalignment.
The film fits into a small undercut on the
face of the button insert. The film is held
securelywhentheouterbuttonandinsert
are snapped together. (Note: It is difficult
to disassemble for legend changes with-
out damaging the parts.)
Button and insert should be snapped to-
gether prior to being assembled to the
button shell.
Button Button and metal shell
Example:
4B1AGN
Green (transmitted color) unlegended
button. (If the button shell is also desired,
substitute 4B2 for 4B1.) Note:legendedbuttonshouldbeassem-
bled as shown above, with button notch
keyed to lamp removal slot in shell. This
will reduce possibility of lamp droppage
when button is removed from the hous-
ing.Buttonsare legended inthismanner.
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
108 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
LAMP ORDER GUIDE
Catalog Illum.
Listing Code Incandescent Lamp Description
4Z221 21 #161 12-volt (T-314)
4Z231 31 #656 or #152 28-volt (T-314)
REPLACEMENT PARTS
MOUNTING CLIPS ORDER GUIDE
Catalog
Listing Description
4Z31 For long sides
4Z32 For short sides
* Each housing requires tqo long or short mounting
clips.
LAMP DATA
Following data was compiled from manufacturers’ specifications and is provided for
reference only.
Illum. Industry Design
Code Lamp No. Volts Incandescent Lamp Specifications
21 161 14 Socket volts 14.0 12.0 11.0
Amps .19 .17 .16
MSCP 1.0 .60 .4
Life (hrs. avg.) 4,000 25,000 26,500
31 656 28 Socket volts 28.0 27.0 26.0
or Amps .06 .057 .054
152 MSCP .65 .52 .49
Life (hrs. avg.) 5,000 7,500 10,000
METAL SHELL ORDER GUIDE
Catalog
Listing Description
4Z41 For type 4B1 buttons
4Z42 For type 4B3 buttons
MOUNTING CENTERS FOR STRIP MOUNT
PANEL CUTOUT FOR INDIVIDUAL
MOUNT (any housing style)
PANEL CUTOUT FOR STRIP MOUNT
+0,38 +.015
Dimensions 0,00 .000
Housing
Style Width Length
Short
Sides
Abutting
Full Bezel 79N(20,1 mm) [No. of units x 1.03N(26,2 mm)] - .05N(1,4 mm)
Short Barrier 79N(20,1 mm) [No. of units x 1.09N(27,8 mm)] - .12N(3,0 mm)
Long
Sides
Abutting
Full Bezel .98N(24,8 mm) [No. of units x .84N(21,3 mm)] - .05N(1,4 mm)
Long Barrier .98N(24,8 mm) [No. of units x .91N(23,1 mm)] - .12N(3,0 mm)
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 109
MOUNTING DIMENSIONS (For reference only)
Terminal View
.110QC terminal Printed circuit
terminal
Quick-connect terminals are .110N(2,8 mm) wide
by.020N(0,5mm)thick.Theslotis.130N(3,3mm)
long by .048N(1,2 mm). Printed circuit terminals
are: Lamp .025 (0,6 mm) by .020N(0,5 mm):
Switch .025N(0,6 mm) square.
All terminals are plated to permit soldering.
Panel thickness: .040-.200 in. (1,02-5,08 mm)
Key: 0,0 =mm
0.00 =inches
Forproperlegendorientation,Series4switchwhenviewedfromfrontofpanel,should
haveterminals1and3upforFigures1&3andtotherightforFigures2and4.(Figures1-4
on Legend Order Sheet next page.)
Type A Button Type B Button TypeC&EButtons TypeD&FButtons
(5 sides lighted) (5 sides lighted) (5 sides lighted) (Only face lighted)
Transparent Button Transparent Button
Translucent Translucent Type C-Black Type D-Black
Colored Button White Button Type-E Colorless Type F-Colorless
Type G Button
(5 sides lighted)
Translucent Transparent Translucent Opaque Black Insert
Colored Button Colored Insert Colored Insert With Translucent
±.005/0,13 Colored Face
*Thickness: .004Nto .007N/0,1 to 0,18 (Film furnished by customer)
Pushbuttons
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches Series 4
Pushbutton Switches and Indicators
110 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
8Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
FEATURES/BENEFITS
1
Designed and manufactured to meet the specific
needs of your application including these
feature options:
Custom layout.
Wideselectionofbuttonsizes and colors capa-
ble of replacement from the panel front.
Full-face lighted buttons.
Legend service on buttons.
Can be furnished wired-only or with built-in inter-
face electronics.
Provisionforincludinglightedmessagedisplays.
Termination direct to PC board.
Custom enclosures available.
1
Tactile feedback of switching action.
1
Low-cost installation complete assembly is
furnished ready to attach with mounting screws.
Mass termination to plug-in connector saves
wiring time.
1
Low energy contacts compatible with
microprocessors and other low level logic
circuitry.
1
Advanced construction and manufacturing
processes reflect the MICRO SWITCH
commitment to high quality, reliability, and
performance.
These low-profile pushbutton panels
combinethelatest advancementsincon-
ductive rubber switching technology and
pushbuttons in a custom package, tai-
lored to your requirements. They meet
theneedsforreliablemanualswitchingin
applications that do not normally require
high speed thruput.
Featuring.100inch(2,4mm)highbuttons
and a .505 inch (12,8 mm) panel frame
depth, their low profile easily adapts to
your system’s styling and package size
requirements. Your design can include a
provisionfordigitalreadouts,CRTs,LCDs
andothersolidstatelightedmessagedis-
plays, encoders, microprocessors, etc.
which can be either assembled by you or
MICRO SWITCH.
TYPICAL APPLICATIONS
1
Marine Control Panels
1
Instrumentation
1
Banking Machines
1
Office Copiers
1
Test Equipment
1
Vending Machines
1
Medical Monitoring and Diagnostic
Devices
1
Telecommunications Equipment
1
Hand-Held Controllers
1
Programmable Controllers
1
Security Entrance Control
1
Industrial Controls
SPECIFICATIONS
Environmental
Operating Temperature –40°Cto65°C (–40°to 149°F)
Storage Temperature –40°Cto70°C (–40°to 158°F)
Altitude –100 to 50,000 ft.
Vibration MIL-STD-202F, Method 204, Condition A frequency to 500
cycles: .06 in. double amplitude or 10 G’s and a frequency
range of 10 to 500 cycles.
Shock MIL-STD-202F, Method 213B, ConditionA–50G’s, 1/2 sine, 11
millisecond pulse.
Sulphur Atmosphere Withstands a sulphur atmosphere at 80% RH. 60°C (140°F) for
10 days
Steady State Humidity MIL-STD-202F, Method 103B, Condition B 90-95% RH at 40°C
for 96 hours. Insulation resistance will not be less than 10
megohmns min.
Mechanical
Travel (nominal) 1,3 mm (.05 in.)
Operating Force (typical) 125 grams (4.4 oz. approx.)
Operating Life 10 x 106operations, 95% survival.
Force deflection (nominal) Peak force, 125 grams (4.4 oz. approx.); Drop-off force, 60
grams (2.1 oz. approx.) (See force deflection curve chart.)
Electrical
Contact Rating 30 mA @ 12 VDC, .500 sec. contact duration
Closed Circuit Resistance 500 ohms max. over life.
Open Circuit Resistance 10 megohmns min.
Contact Disturbance Time 10 millisec. max. at 2 lbs. (8,9 Newtons) full overtravel force,
when mechanically actuated at 4 in. (10,6 mm) sec. plunger
velocity.
Capacitance Less than 20 picofarads per station.
Circuitry X-Y or common bus.
LED Vf Forward Voltage: 5V
If Forward Current: 30 mA typ.
Vr Reverse Voltage: 4V
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
OBSOLETE
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 9
SLP1ORDER GUIDE (All possible combinations may not be available.)
SLP1 3 2 A 12 27
Button Color1
SLP Series Circuitry Lighting Legend Matrix Unlighted Lighted
SLP1 2-XY
3-Common
Bus
0-Unlighted
1-Red LEDs
2-Green LEDs
3-Yellow LEDs
4-Combination
of LEDs
A-No Legend
B-Legended
Black ink2
C-Legended
White ink2
D-Legended
Black and
White ink2
4-1×4
12-3×4
16-4×4
20-4×5
-10 Gray -25 Red
-11 White -26 Yellow
-12 Red -27 Green
-13 Yellow -28 White
-14 Green -29 Clear
-15 Green (matches
lighted green)
-16 Blue
-18 Black
1Factory will assign non-standard LED and button colors and combinations. Complete SLP Custom Order Sheet.
2SLP Custom Order Sheet must accompany order.
Example:
SLP132A12-27 Common bus circuitry, green LEDS, no legend, 3×4 with green buttons.
INDIVIDUAL BUTTON CATALOGING
SLP51 A 20 G
Open Color
Button Style Field Legending Unlighted Lighted
SLP51-Unlighted
SLP52-Lighted A 10-No legend
20-Legended
Black ink1
21-Legended
White ink2
–R Red
–G Green
–U Green (matches
lighted green)
–Y Yellow
–B Blue
–WWhite
–K Black
–A Gray
–R Red
–U Green
–Y Yellow
–W White
1SLP Custom Order Sheet must accompany order.
Example: SLP51A20-G
Green unlighted button legended
with black ink.
CONSTRUCTION
The top switching layer is a conductive
rubber boot sheet (see cutaway draw-
ing). When force is applied to a button,
contactismadebetweenthebootandthe
bottom circuit layer on a printed circuit
board. The boots impart an excellent tac-
tile feedback (see force deflection curve
chart).
A molded plastic housing, with panel
slots for buttons and mounting holes in
each corner, is placed over all compo-
nents and ultrasonically welded to the
printed circuit board. Interface circuitry
canbeeasilyaddedtothePCBbytheus-
er or furnished built-in.
CUTAWAY VIEW
ILLUMINATION
Full face button lighting is provided by
red,green,andyellowLEDs.(LEDcolors
shouldbethesameasthebuttontheyillu-
minate.)Thestandard SLP1offering isfor
use under general office lighting condi-
tions, which is usually about 80 foot can-
dles. (LEDs with less brightness can be
provided.)
TERMINATION
A header type connector provides termi-
nation directly from the printed circuit
board. Products shown here have
straight exit headers (see mounting di-
mension drawings). Right angle exit
headerconnectorscanalsobefurnished.
Connector pins are .025 inch (0,64mm)
square, on .100 inch (2,54 mm) centers,
by .318 inch long. Suitable for use with
vast array connector manufacturers’
standard products.
Force Deflection Curve
Pushbutton
Panels
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
10 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
1 X 4 PANEL
Note: Connector pins are .418 in./10,6 mm long.
LIGHTED
With C, Bus Sw. Cktry.
Station Switch LED Pins:
No.s Pins: Pos. Neg.
1 3-8 1-5
2 4-8 2-5
3 6-8 10-5
4 7-8 9-5
NON-LIGHTED
Station Switch
No. Pins
1 1-5
2 2-5
3 3-5
4 4-5
3X4PANEL
Note: Connector pins are .418 in./10,6 mm long.
LIGHTED
With X-Y Sw. Cktry. With C. Bus Cktry.
Station Switch LED Pins: Switch LED Pins:
Nos. Pins: Pos. Neg. Pins: Pos. Neg.
1 6-7 1-8 9-10 1-12
2 6-9 15-8 9-14 21-12
3 6-10 19-8 9-20 25-12
4 11-7 2-8 9-7 2-12
5 11-9 16-8 9-11 22-12
6 11-10 20-8 9-18 26-12
7 12-7 3-8 9-6 3-12
8 12-9 13-8 9-13 19-12
9 12-10 17-8 9-17 23-12
10 14-7 4-8 9-8 4-12
11 14-9 5-8 9-15 5-12
12 14-10 18-8 9-16 24-12
NON-LIGHTED
With X-Y
Station Cktry. With C. Bus Ckty.
Nos. Switch Pins: Switch Pins:
1 4-5 4-13
2 4-6 8-13
3 4-7 12-13
4 3-5 3-13
5 3-6 7-13
6 3-7 11-13
7 2-5 2-13
8 2-6 6-13
9 2-7 10-13
10 1-5 1-13
11 1-6 5-13
12 1-7 9-13
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 11
4x4PANEL
Note: Connector pins are .418 in./10,6 mm long.
LIGHTED
With X-Y Sw. Cktry. With C. Bus Sw. Cktry.
Station Switch LED Pins: Switch LED Pins:
Nos. Pins: Pos. Neg. Pins: Pos. Neg.
1 15-9 2-10 3-27 2-5
2 15-12 5-10 11-27 10-5
3 15-13 21-10 24-27 31-5
4 15-16 26-10 28-27 34-5
5 18-9 1-10 4-27 1-5
6 18-12 7-10 9-27 13-5
7 18-13 6-10 23-27 12-5
8 18-16 25-10 25-27 33-5
9 17-9 3-10 6-27 7-5
10 17-12 14-10 16-27 18-5
11 17-13 24-10 26-27 22-5
12 17-16 22-10 21-27 32-5
13 20-9 4-10 17-27 8-5
14 20-12 11-10 20-27 15-5
15 20-13 8-10 19-27 14-5
16 20-16 19-10 30-27 29-5
NON-LIGHTED
With X-Y
Station Cktry. With C. Bus Cktry.
Nos. Switch Pins: Switch Pins:
1 3-2 4-17
2 3-6 8-17
3 3-7 12-17
4 3-8 16-17
5 5-2 3-17
6 5-6 7-17
7 5-7 11-17
8 5-8 15-17
9 4-2 2-17
10 4-6 6-17
11 4-7 10-17
12 4-8 14-17
13 1-2 1-17
14 1-6 5-17
15 1-7 9-17
16 1-8 13-17
5X4PANEL
Note: Connector pins are .418 in./10,6 mm long.
NOTE:
In addition to the recessed mounting hole style shown, units can be
furnished with straight thru-holes for rear panel mounting or blind holes
for front panel mounting (see drawings below).
Rear Panel Mount Front Panel Mount
LIGHTED5x4PANEL
With X-Y Sw. Cktry. With C. Bus Cktry.
Station Switch LED Pins: Switch LED Pins:
Nos. Pins: Pos. Neg. Pins: Pos. Neg.
1 15-7 3-23 3-38 7-28
2 15-8 2-23 8-38 2-28
3 15-13 1-23 22-38 1-28
4 14-21 29-23 32-38 41-28
5 15-26 30-23 37-38 33-28
6 19-7 4-23 4-38 10-28
7 19-8 9-23 15-38 11-28
8 19-13 18-23 21-38 19-28
9 19-21 25-23 31-38 30-28
10 19-26 28-23 40-38 29-28
11 17-7 5-23 5-38 9-28
12 17-8 11-23 17-38 13-28
13 17-13 16-23 24-38 20-28
14 17-21 20-23 36-38 25-28
15 17-26 27-23 42-38 34-28
16 14-7 6-23 6-38 12-28
17 14-8 10-23 18-38 14-28
18 14-13 12-23 23-38 16-28
19 14-21 22-23 35-38 26-28
20 14-26 24-23 39-38 27-28
NON-LIGHTED
With X-Y
Station Cktry. With C. Bus Cktry.
Nos. Switch Pins: Switch Pins:
1 4-5 4-21
2 4-6 8-21
3 4-7 12-21
4 4-8 16-21
5 4-9 20-21
6 3-5 3-21
7 3-6 7-21
8 3-7 11-21
9 3-8 15-21
10 3-9 19-21
11 2-5 2-21
12 2-6 6-21
13 2-7 10-21
14 2-8 14-21
15 2-9 18-21
16 1-5 1-21
17 1-6 5-21
18 1-7 9-21
19 1-8 13-21
20 1-9 17-21
Pushbutton
Panels
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Custom Low-Profile Pushbutton Panels
12 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
MODULAR SWITCH DESIGN
PROVIDES CUSTOM FLEXIBILITY
Thisnewmodularswitchdesignincorpo-
rates the same basic construction fea-
tures as the MICRO SWITCH SLP push-
button panel, plus gives you the flexibility
ofspecifyinganyswitchmatrixconfigura-
tion.
Standard buttons are .583-inch square.
Other button sizes can be furnished to
suit your application needs.
Themodularswitchconstructionfeatures
good ergonomics with positive tactile
feedbackwhichimpartsagoodfeelofthe
switching action, and compatibility with
microprocessors and other low-level log-
ic circuitry.
The addition of a polyurethane sheet, en-
ablestheSLPmodularswitchtomeetwa-
ter spray and dust sections of NEMA12.
HOW TO SPECIFY CUSTOM ARRAYS
Use the SLP Custom Order Sheet to
specifyyourdesiredbuttonlayout,button
colors, LED colors (unless buttons are to
be unlighted), and legend sizes and col-
ors (unless the buttons are to be unleg-
ended).
A copy of the order sheet is on the next
two pages. Reproduce it on your office
copier or request copies of form
FO-64419.
Note: To enhance the display when the
buttonsaretobelightedbyLEDs,thebut-
tons should be either the same color as
the LEDs or white buttons.
APPLICATION ASSISTANCE
Our field engineer/factory team will be
happy to work with you every step of the
way—through concept, design, and
manufacturing—to help insure your cus-
tom package has a quality appearance
and performs just the way you want it.
Contact the 800 number.
PANEL SEAL ACCESSORY
SLP 3 ×4 array with panel seal.
Elastomer silicon seals fit over SLP pan-
els to help protect their circuitry and be-
hind panel components from contami-
nantsthatmightenterthroughtheswitch.
See photo.
The seal is positioned be-
tween rear mounted units and the user’s
mountingpanel.Whenproperlyinstalled,
it meets NEMA 13, providing a degree of
protection against dust, spraying of wa-
ter,oil,detergent,andnon-corrosivecoo-
lant. (Installation instructions furnished
with seals.)
Silicon has good natural resistance to ul-
traviolet light and no UV inhibitors are re-
quired.Thismaterialhasbeenthoroughly
evaluated for chemical resistance. For
further information, contact the 800 num-
ber.Use ofthesealdoesnot lessenoper-
ating life.
Note:
SLP panels with thru-hole mounting are
recommendedforusewiththepanelseal.
Sealing is most effective when mounting
screws are torqued to 6±1.5 in./lbs.
ORDER GUIDE PANEL SEALS
Array Catalog Listing
1×4 SLP61-4
3×4 SLP61-12
4×4 SLP61-16
5×4 SLP61-20
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 13
Pushbutton
Panels
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
14 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SLP1Series
Low-Profile Pushbutton Panels
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 15
Pushbutton
Panels
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Manual Switches SN/SD Series
Hall Effect Keyboards/Modules
16 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
SD HALL EFFECT KEYBOARDS
MICRO SWITCH SD Series Hall effect
keyboards meet high performance, cus-
tom design, full-travel keyboard needs.
They’re unsurpassed for switch speed,
reliability and accuracy. Modular con-
structionallows flexibilityin keyboardlay-
out and size.
Hall effect keyboards are offered in stan-
dard profile and low profile, sealed or un-
sealed,instandard arrays,andin custom
arraystailored tofittheuser’sspecific ap-
plication. Hall effect keyboards are capa-
ble of handling very high throughput ap-
plications.
A sealed version of the Hall effect key-
board (101SD29-2E-S-H) designed for
harshdutyindustrialenvironmentsmeets
NEMA 4 and 13 water/moisture resist-
ance standards.
Request Product Sheets:
26SD 84-02506
32SD 84-02502
63SD 84-02504
101SD 84-02501
12/16SD 84-02607
SN/SD HALL EFFECT KEYSWITCH
MODULES
SNandSDSerieskeyswitchmodulesare
ideal for building custom arrays, such as
keyboards, control/switch panels, and
switch matrices. Lighted display options
are available.
SN modules are available in types that
can be either snap-in panel mounted or
mounteddirectlytoprintedcircuitboards
without additional mounting or support
hardware. Request Product Sheet 84-
02508.
SDmoduleshavealowerprofilethanSN.
Theysecurely mount in a metal grid plate
which provides support and enhances
good keytop alignment between stations
and rows. Request Product Sheet 84-
02505.
SD Grid Plate Mount
SN PC Board Mount
SN Snap-in Panel Mount
For further information on Hall effect
keyboards, keytops, and modules, con-
tact your nearest MICRO SWITCH sales
office. Or call1-800-537-6945.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
OBSOLETE
Manual Switches
Sealed Toggle Switches NT Series/Flat Base
FEATURES
Completely sealed
switching chamber
IP67/IP68
NEMA 3, 3R, 4, 13
2- or 3-position maintained
and momentary action
Flat base with quick
connect terminals – mating
connectors are available
Spring-loaded actuating
mechanism provides
excellent tactile feedback
GENERAL INFORMATION
Honeywell NT Series toggle switches meet the need for a rugged, cost-
effective toggle switch. Quality construction features include a seal between
the toggle lever and bushing, and between the cover and case. These
switches can be used where panels are subject to splashes, hosedowns, or
outdoor environments. Complete sealing of the switching chamber enables
NT toggles to comply with UL 508, paragraph 13.3 hosedown test. They will
also withstand exposure to heavy accumulations of early morning dew that
may condense on the control panel in cabs of vehicles left outdoors
overnight. The “Easy Start” threaded bushing enables quick alignment of the
mounting nut to decrease the chance of cross threading. The panel stand-off
with O-ring feature available on some listings eliminates the need for behind-
the-panel hardware, provides a uniform panel height, and provides a panel-
to-cover seal.
UL recognized, File
E12252, Vol. 1, Section 44
CSA certified, CE certified
Optional panel stand-off
with O-ring panel seal
TYPICAL APPLICATIONS
Industrial equipment
Military and commercial
aviation
Construction equipment
Test instruments UL AND CSA ELECTRICAL RATINGS
Agricultural machinery Rating Code Electrical rating
L192 10 amps, 125, 250, 277 Vac; ¼ Hp, 125 Vac; ½ Hp, 250, 277 Vac;
3 amps, 125 Vac “L”
L191 15 amps, 125, 250, 277 Vac; ½ Hp, 125 Vac; 1 Hp, 250, 277 Vac;
5 amps, 125 Vac “L”
Process control
Medical instrumentation
ELECTRICAL RATINGS
Elect.
Rating
Code
28 Volts DC 115
Vdc
250
Vdc
115 Vac,
60 Hz & 400 Hz
230
Vac
Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res
1 12 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
4 10 18 5 0.75 0.5 8 11 2 6
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Manual Switches
Sealed Toggle Switches NT Series/Flat Base
NT 2-POSITION ORDER GUIDE
Circuits Made with Toggle At:
No. of
poles Keyway Position Opposite
Keyway
UL
Rating
Code
Elect. Rating
Code
Catalog Listing
Toggle Q-C
1 OFF 2-3 L191 1 31NT91-2
1-2 2-3 L191 1 31NT91-3
OFF** 2-3 L192 2 31NT91-4
1-2** OFF L192 2 31NT91-6
1-2** 2-3 L192 2 31NT91-8
2 OFF 2-3, 5-6 L191 3 32NT91-2
1-2, 4-5 2-3, 5-6 L191 3 32NT91-3
OFF** 2-3, 5-6 L192 4 32NT91-4
1-2, 4-5** OFF L192 4 32NT91-6
1-2, 4-5** 2-3, 5-6 L192 4 32NT91-8
** These positions are momentary. All others are maintained.
NT 2-POSITION ORDER GUIDE • PANEL STAND-OFF FEATURE
Circuits Made with Toggle At:
No. of
poles Keyway Position Opposite
Keyway
UL
Rating
Code
Elect. Rating
Code
Catalog Listing
Toggle Q-C
1 OFF 2-3 L191 1
631NT91-2
631NT91-3
631NT91-4
631NT91-6
631NT91-8
2 OFF 2-3, 5-6 L191 3 632NT91-2
1-2, 4-5 2-3, 5-6 L191 3 632NT91-3
632NT91-4
1-2, 4-5** OFF L192 4 632NT91-6
632NT91-8
** These positions are momentary. All others are maintained. Pick up Keyway Position / Opposite Keyway, etc from standard listings above
that do not have the panel stand-off feature.
MATING CONNECTORS ORDER GUIDE
Description Catalog listing
2-pole connector 19PA168-NT
1-pole connector, same package size as 2-pole connector 19PA169-NT
2 Honeywell Sensing and Control
Manual Switches
Sealed Toggle Switches NT Series/Flat Base
NT 3-POSITION ORDER GUIDE
Circuits made with toggle at:
No. of
poles Keyway Position Center Position Opposite Keyway
UL
Rating
Code
Elect. Rating
Code
Catalog Listing
Toggle Q-C
1 1-2 OFF 2-3 L191 1 31NT91-1
1-2** OFF 2-3 L192 2 31NT91-5
1-2** OFF 2-3** L192 2 31NT91-7
NONE*** OFF 2-3 L191 1 31NT91-21
NONE*** 1-2 2-3 L191 1 31NT91-31
NONE*** 1-2 2-3** L192 2 31NT91-51
1-2** OFF NONE*** L192 2 31NT91-61
2 1-2, 4-5 OFF 2-3, 5-6 L191 3 32NT91-1
1-2, 4-5** OFF 2-3, 5-6 L192 4 32NT91-5
1-2, 4-5** OFF 2-3, 5-6** L192 4 32NT91-7
NONE*** OFF 2-3, 5-6 L191 3 32NT91-21
NONE*** 1-2, 4-5 2-3, 5-6 L191 3 32NT91-31
NONE*** 1-2, 4-5 2-3, 5-6** L192 4 32NT91-51
1-2, 4-5** OFF NONE*** L192 4 32NT91-61
1-2, 4-5 2-3, 5-6 2-3, 5-6 L191 3 32NT91-12
1-2, 4-5 1-2, 5-6 2-3, 5-6 L191 3 32NT91-10
1-2, 4-5** 1-2, 5-6 2-3, 5-6 L192 4 32NT91-50
1-2, 4-5** 1-2, 5-6 2-3, 5-6** L192 4 32NT91-70
** These positions are momentary. All others are maintained.
*** Toggle lever is blocked from these positions. Toggle becomes 2-position, with center being one extreme position.
NT 3-POSITION ORDER GUIDE • PANEL STAND-OFF FEATURE
Circuits made with toggle at:
No. of
poles Keyway Position Center Position Opposite Keyway
UL
Rating
Code
Elect. Rating
Code
Catalog Listing
Toggle Q-C
1 1-2** OFF 2-3** L192 2
631NT91-7
631NT91-1
631NT91-5
2 1-2, 4-5 OFF 2-3, 5-6 L191 3 632NT91-1
1-2, 4-5** OFF 2-3, 5-6 L192 4 632NT91-5
1-2, 4-5** OFF 2-3, 5-6** L192 4 632NT91-7
632NT91-70
** These positions are momentary. All others are maintained
Honeywell Sensing and Control 3
Manual Switches
Sealed Toggle Switches NT Series/Flat Base
Sensing and Control
Honeywell
11 West Spring Street
MOUNTING DIMENSIONS
For reference only mm/in
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com
Freeport, Illinois 61032
005420-2-EN IL50 GLO 1103 Printed in USA
Copyright 2003 Honeywell International Inc. www.honeywell.com/sensing
Manual Switches
Sealed Toggle Switches NT Series/Step Base
FEATURES
Completely sealed
switching chamber
IP67/IP68
NEMA 3, 3R, 4, 13
Step-design case provides
added space between
terminals to prevent
shorting GENERAL INFORMATION
Honeywell NT Series toggle switches meet the need for a rugged, cost-
effective toggle switch. Quality construction features include a seal between
the toggle lever and bushing, and between the cover and case. These
switches can be used where panels are subject to splashes, hosedowns, or
outdoor environments. Complete sealing of the switching chamber enables
NT toggles to comply with UL 508, paragraph 13.3 hosedown test. They will
also withstand exposure to heavy accumulations of early morning dew that
may condense on the control panel in cabs of vehicles left outdoors
overnight. The “Easy Start” threaded bushing enables quick alignment of the
mounting nut to decrease the chance of cross threading. The panel stand-off
with O-ring feature available on some listings eliminates the need for behind-
the-panel hardware, provides a uniform panel height, and provides a panel-
to-cover seal.
1, 2, or 4-pole circuitry
Spring-loaded actuating
mechanism provides
excellent tactile feedback
UL recognized, File
E12252, Vol. 1, Section 44
CSA certified, CE certified
Optional panel stand-off
with O-ring panel seal
TYPICAL APPLICATIONS
Industrial equipment
Military and commercial
aviation UL AND CSA ELECTRICAL RATINGS
Rating Code Electrical rating
L192 10 amps, 125, 250, 277 Vac; ¼ Hp, 125 Vac; ½ Hp, 250, 277 Vac;
3 amps, 125 Vac “L”
L191 15 amps, 125, 250, 277 Vac; ½ Hp, 125 Vac; 1 Hp, 250, 277 Vac;
5 amps, 125 Vac “L”
Construction equipment
Test instruments
Agricultural machinery
Process control
Medical instrumentation
ELECTRICAL RATINGS
Elect.
Rating
Code
28 Volts DC 115
Vdc
250
Vdc
115 Vac,
60 Hz & 400 Hz
230
Vac
Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res
1 12 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
4 10 18 5 0.75 0.5 8 11 2 6
WARNING
PERSONAL INJURY
DO NOT USE these
products as safety or
emergency stop devices or
in any other application
where failure of the product
could result in personal
injury.
Failure to comply with
these instructions could
result in death or serious
injury.
Sensing and Control
WARNING
MISUSE OF DOCUMENTATION
The information presented in this product sheet is for reference only. Do
not use this document as a product installation guide.
Complete installation, operation, and maintenance information is provided
in the instructions supplied with each product.
Failure to comply with these instructions could result in death or
serious injury.
Manual Switches
Sealed Toggle Switches NT Series/Step Base
NT 2-POSITION ORDER GUIDE
Standard Lever
Circuits made with toggle at: Termination Style
No. of
Poles Keyway Position Opposite Keyway
UL
Rating
Code
Elect.
Rating
Code
Screw Solder Q-C
1 OFF 2-3 L191 1 1NT1-2 11NT1-2 1NT91-2
1-2 2-3 L191 1 1NT1-3 11NT1-3 1NT91-3
OFF* 2-3 L192 2 1NT1-4 11NT1-4 1NT91-4
1-2* OFF L192 2 1NT1-6 11NT1-6 1NT91-6
1-2* 2-3 L192 2 1NT1-8 11NT1-8 1NT91-8
2 OFF 2-3, 5-6 L191 3 2NT1-2 12NT1-2 2NT91-2
1-2, 4-5 2-3, 5-6 L191 3 2NT1-3 12NT1-3 2NT91-3
OFF* 2-3, 5-6 L192 4 2NT1-4 12NT1-4 2NT91-4
1-2, 4-5* OFF L192 4 2NT1-6 12NT1-6 2NT91-6
1-2, 4-5* 2-3, 5-6 L192 4 2NT1-8 12NT1-8 2NT91-8
4 OFF 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-2 14NT1-2 4NT91-2
1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-3 14NT1-3 4NT91-3
OFF* 2-3, 5-6, 8-9, 11-12 L192 6 4NT1-4 14NT1-4 4NT91-4
1-2, 4-5, 7-8, 10-11* OFF L192 6 4NT1-6 14NT1-6 4NT91-6
1-2, 4-5, 7-8, 10-11* 2-3, 5-6, 8-9, 11-12 L192 6 4NT1-8 14NT1-8 4NT91-8
* These positions are momentary. All others are maintained.
NT 2-POSITION ORDER GUIDE • PANEL STAND-OFF FEATURE
Circuits Made with Toggle At: Standard Lever
No. of
Poles Keyway Position Opposite Keyway
UL
Rating
Code
Elect.
Rating
Code
Screw
1 OFF 2-3 L191 1 61NT1-2
1-2 2-3 L191 1 61NT1-3
1-2* OFF L192 2 61NT1-6
1-2* 2-3 L192 2 61NT1-8
2 OFF 2-3, 5-6 L191 3 62NT1-2
1-2, 4-5 2-3, 5-6 L191 3 62NT1-3
1-2, 4-5* OFF L192 4 62NT1-6
1-2, 4-5* 2-3, 5-6 L192 4 62NT1-8
* These positions are momentary. All others are maintained.
2 Honeywell Sensing and Control
Manual Switches
Sealed Toggle Switches NT Series/Step Base
NT 3-POSITION ORDER GUIDE
Standard Lever
Circuits Made with Toggle At: Termination Style
No. of
Poles Keyway Position Center Position Opposite Keyway
UL
Rating
Code
Elect.
Rating
Code
Screw Solder Q-C
1 1-2 OFF 2-3 L191 1 1NT1-1 11NT1-1 1NT91-1
1-2* OFF 2-3 L192 2 1NT1-5 11NT1-5 1NT91-5
1-2* OFF 2-3* L192 2 1NT1-7 11NT1-7 1NT91-7
NONE** OFF 2-3 L191 1 1NT1-21 11NT1-21 1NT91-21
NONE** 1-2 2-3 L191 1 1NT1-31 11NT1-31 1NT91-31
NONE** 1-2 2-3* L192 2 1NT1-51 11NT1-51 1NT91-51
1-2* OFF NONE** L192 2 1NT1-61 11NT1-61 1NT91-61
2 1-2, 4-5 OFF 2-3, 5-6 L191 3 2NT1-1 12NT1-1 2NT91-1
1-2, 4-5* OFF 2-3, 5-6 L192 4 2NT1-5 12NT1-5 2NT91-5
1-2, 4-5 OFF 2-3, 5-6* L192 4 2NT1-7 12NT1-7 2NT91-7
NONE* OFF 2-3, 5-6 L191 3 2NT1-21 12NT1-21 2NT91-21
NONE** 1-2, 4-5 2-3, 5-6 L191 3 2NT1-31 12NT1-31 2NT91-31
NONE** 1-2, 4-5 2-3, 5-6* L192 4 2NT1-51 12NT1-51 2NT91-51
1-2, 4-5* OFF NONE** L192 4 2NT1-61 12NT1-61 2NT91-61
1-2, 4-5 2-3, 4-5 2-3, 5-6 L191 3 2NT1-12 12NT1-12 2NT91-12
1-2, 4-5 1-2, 5-6 2-3, 5-6 L191 3 2NT1-10 12NT1-10 2NT91-10
1-2, 4-5* 1-2, 5-6 2-3, 5-6 L192 4 2NT1-50 12NT1-50 2NT91-50
1-2, 4-5 1-2, 5-6 2-3, 5-6* L192 4 2NT1-70 12NT1-70 2NT91-70
4 1-2, 4-5, 7-8, 10-11 OFF 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-1 14NT1-1 4NT91-1
1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 L192 6 4NT1-5 14NT1-5 4NT91-5
1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* L192 6 4NT1-7 14NT1-7 4NT91-7
NONE* OFF 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-21 14NT1-21 4NT91-21
NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-31 14NT1-31 4NT91-31
NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12* L192 6 4NT1-51 14NT1-51 4NT91-51
1-2, 4-5, 7-8, 10-11* OFF NONE** L192 6 4NT1-61 14NT1-61 4NT91-61
1-2, 4-5, 7-8, 10-11 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-12 14NT1-12 4NT91-12
1-2, 4-5, 7-8, 10-11 2-3, 4-5 2-3, 5-6, 8-9, 11-12 L191 5 4NT1-10 14NT1-10 4NT91-10
1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 L192 6 4NT1-50 14NT1-50 4NT91-50
1-2, 4-5, 7-8, 10-11* 2-3, 4-5 2-3, 5-6, 8-9, 11-12* L192 6 4NT1-70 14NT1-70 4NT91-70
* These positions are momentary. All others are maintained.
** Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position.
NT 3-POSITION ORDER GUIDE • PANEL STAND-OFF FEATURE
Circuits Made with Toggle At: Termination
No. of
Poles Keyway Position Center Position Opposite Keyway
UL
Rating
Code
Elect.
Rating
Code
Screw
1 1-2 OFF 2-3 L191 1 61NT1-1
1-2* OFF 2-3* L192 2 61NT1-7
2 1-2, 4-5 OFF 2-3, 5-6 L191 3 62NT1-1
1-2, 4-5 OFF 2-3, 5-6* L192 4 62NT1-7
* These positions are momentary. All others are maintained.
Honeywell Sensing and Control 3
Manual Switches
Sealed Toggle Switches NT Series/Step Base
Sensing and Control
Honeywell
11 West Spring Street
MOUNTING DIMENSIONS
For reference only mm/in
WARRANTY/REMEDY
Honeywell warrants goods of its manufacture as
being free of defective materials and faulty
workmanship. Contact your local sales office for
warranty information. If warranted goods are
returned to Honeywell during the period of coverage,
Honeywell will repair or replace without charge those
items it finds defective. The foregoing is Buyer’s
sole remedy and is in lieu of all other warranties,
expressed or implied, including those of
merchantability and fitness for a particular
purpose.
Specifications may change without notice. The
information we supply is believed to be accurate and
reliable as of this printing. However, we assume no
responsibility for its use.
While we provide application assistance personally,
through our literature and the Honeywell web site, it
is up to the customer to determine the suitability of
the product in the application.
For application assistance, current specifications, or
name of the nearest Authorized Distributor, contact a
nearby sales office. Or call:
1-800-537-6945 USA
1-800-737-3360 Canada
1-815-235-6847 International
FAX
1-815-235-6545 USA
INTERNET
www.honeywell.com/sensing
info.sc@honeywell.com
Freeport, Illinois 61032
005421-2-EN IL50 GLO 1103 Printed in USA
Copyright 2003 Honeywell International Inc. www.honeywell.com/sensing
Manual Switches TL Series
Environment-Sealed Toggle Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada39
FEATURES
1
Qualified to MIL-S-3950
1
Environment-proof sealing
1
1, 2, and 4 pole circuitry
1
Standard and pull to unlock levers
1
2 and 3 position, maintained, and mo-
mentary toggle action
1
Temperature range: 85Fto+160F
(–65Cto+71C)
1
Screw, turret solder, and IWTS termi-
nals available
1
UL recognized
1
Colored tab levers available
CONSTRUCTION
TLs have high strength, temperature re-
sistant, non-tracking case material and
silvercadmiumoxidecontacts.Goldcon-
tacts are also available.
ACTUATOR OPTIONS
Standard toggle lever operates on a di-
rect action spring loaded toggle mecha-
nismtoprovideexcellenttactilefeedback
in both the momentary and maintained
toggle positions. The toggle lever is ap-
proximately.68in.(16mm)longandhasa
non-glare matte nickel plated finish.
Pull-to-unlock toggle levers prevent acci-
dental toggle movement. The knobbed
toggle lever must be pulled out approxi-
mately .09 in. (2,3mm) to change posi-
tions. Thirteen different locking configu-
rations are available. This lever style also
has a non-glare matte nickel finish.
ELECTRICAL RATINGS In Amperes
115 Volts AC
28 Volts DC 115 VDC 250 VDC 60 & 400 Hz 230 VAC
Rating
Code* Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res.
1 12 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
4 10 18 5 0.75 0.5 8 11 2 6
5 12 20 5 0.75 0.5 15 15 4 6
6 10 18 4 0.75 0.5 8 11 2 6
UL AND CSA ELECTRICAL RATINGS
Rating Code* Electrical Rating
L192 10 amps-125, 250, 277 VAC; 14HP-125 VAC; 12HP-250, 277 VAC
3 amps-125 VAC
‘‘
L’’
L191 15 amps-125, 250, 277 VAC; 12HP-125 VAC; 1 HP-250, 277 VAC
5 amps-125 VAC
‘‘
L’’
* Referred to in order guides.
Application Note: Honeywell MICRO SWITCH does
not
recommend the use of silver
cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally
loadslessthan12voltsand/or0.5amp.TLswitchesusesilvercadmiumoxidecontact.
If you have specific questions, contact the MICRO SWITCH Application Center at
1-800-537-6945.
Manuals
Manual Switches TL Series
Environment-Sealed Toggle Switches
40HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
TERMINAL CIRCUIT
IDENTIFICATION
Terminal identifications are referred to in
theorderguidestoindicatewhichcircuits
aremadeineachtoggleposition(i.e.,1-2
refers to circuit closure through terminals
1and 2).
One pole
Two pole
Four pole
SPECIAL CIRCUITRIES
Catalog listings with -10, -50, and -70 suf-
fix numbers shown in the order guides
have special ‘‘On-On-On’’ circuits, as il-
lustrated. TLs with -12 suffix are the same
as-50exceptthekeywaypositionismain-
tained, and in the center position circuits
2-3 and 4-5 are made; -72 is the same as
-50exceptthattheoppositekeywayposi-
tionismomentary, and in the center posi-
tion circuits 2-3 and 4-5 are made.
-10 CIRCUITRY
No. of Keyway Side Center Opposite Keyway
Poles Maint. Position Maint. Position Maint. Position
2
4
-50 CIRCUITRY
No. of Keyway Side Center Opposite Keyway
Poles Mom. Position Maint. Position Maint. Position
2
4
-70 CIRCUITRY
No. of Keyway Side Center Opposite Keyway
Poles Mom. Position Maint. Position Mom. Position
2
4
Manual Switches TL Series
Environment-Sealed Toggle Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada41
TL 2-POSITION ORDER GUIDE
Circuit(s) Made With
Toggle At: Page 39 Standard Toggle Pull-to-Unlock Toggle
Locking Configuration
Electrical UL/CSA Add Suffix to
No. of Keyway Opposite Rating Rating Catalog Military Standard Military
Poles Position Keyway Code Code Listing Number Toggle Listing Number**
1 OFF 2-3 1 L191 1TL1-2 MS24523-22 D, F, G MS24658-22
OFF* 2-3 2 L192 1TL1-4 MS24523-29 F MS24658-29
1-2* OFF 2 L192 1TL1-6 MS24523-30 F MS24658-30
1-2 2-3 1 L191 1TL1-3 MS24523-23 D, F, G MS24658-23
1-2* 2-3 2 L192 1TL1-8 MS24523-26 F MS24658-26
2 OFF 2-3, 5-6 3 L191 2TL1-2 MS24524-22 D, F, G MS24659-22
OFF* 2-3, 5-6 4 L192 2TL1-4 MS24524-29 F MS24659-29
1-2, 4-5* OFF 4 L192 2TL1-6 MS24524-30 F MS24659-30
1-2, 4-5 2-3, 5-6 3 L191 2TL1-3 MS24524-23 D, F, G MS24659-23
1-2. 4-5* 2-3, 5-6 4 L192 2TL1-8 MS24524-26 F MS24659-26
4 OFF 2-3, 5-6 5 L191 4TL1-2 MS24525-22 D, F, G MS24660-22
8-9, 11-12
OFF* 2-3, 5-6 6 L192 4TL1-4 MS24525-29 F MS24660-29
8-9, 11-12
1-2, 4-5 OFF 6 L192 4TL1-6 MS24525-30 F MS24660-30
7-8, 10-11*
1-2, 4-5 2-3, 5-6 5 L191 4TL1-3 MS24525-23 D, F, G MS24660-23
7-8, 10-11 8-9, 11-12
1-2, 4-5* 2-3, 5-6 6 L192 4TL1-8 MS24525-26 F MS24660-26
7-8, 10-11 8-9, 11-12
* These positions only are momentary. All others are maintained.
** Also add the appropriate suffix letter to the Military number.
PULL-TO-UNLOCK OPTION
When ordering pull-to-unlock toggle list-
ings, add the suffix letter shown in the
chart below to the standard toggle listing
and the MS number. For example, to or-
der a 1TL1-1 pull-to-unlock toggle switch
with the lever locked in the center posi-
tion, add the letter E; i.e., 1TL1-1E,
MS-24658-21E.
LOCKING CONFIGURATIONS
ABDEFGH
Locked In Locked Out Of
Center and Locked Out Locked In Locked In Center And
Locked In Extreme Position Of Center Locked In Extreme Position Extreme Position Extreme Position
Three Positions (Keyway Side) Position Center Position (Opposite Keyway) (Keyway Side) (Keyway Side)
JKLMNP
Locked Out Of Locked In Locked Out Of Locked Out Of
Center And Center And Locked Out Of And Into Locked Out Of And Into
Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position
(Opposite Keyway) (Opposite Keyway) (Keyway Side) (Opposite Keyway) (Opposite Keyway) (Keyway Side)
Manuals
ManualSwitchesTLSeries
Environment-Sealed Toggle Switches
42HoneywellensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
TL 3-POSITION ORDER GUIDE
Circuit(s) Made With Toggle At: Page 39 Standard Toggle Pull-to-Unlock Toggle
Locking Configuration
Elec. UL/CSA Add Suffix toNo.
of Keyway Center Opposite Rating Rating Catalog Military Standard Military
Poles Position Position Keyway Code Code Listing Number*** Toggle Listing Number***
1 1-2 OFF 2-3 1 L191 1TL1-1 MS24523-21 ALL TYPES MS24658-21
1-2* OFF 2-3 2 L192 1TL1-5 MS24523-31 E, F, K, L, M, N MS24658-31
1-2* OFF 2-3* 2 L192 1TL1-7 MS24523-27 E, L, N MS24658-27
None** OFF 2-3 1 L191 1TL1-21 MS24523-24 E, F, K, M MS24658-24
None** 1-2 2-3 1 L192 1TL1-31 MS24523-33 E, F, K, M MS24658-33
None** 1-2 2-3* 2 L192 1TL1-51 MS24523-32 E MS24658-32
1-2* OFF None** 2 L192 1TL1-61 MS24523-28 E MS24658-28
2 1-2, 4-5 OFF 2-3, 5-6 3 L191 2TL1-1 MS24524-21 ALL TYPES MS24659-21
1-2, 4-5* OFF 2-3, 5-6 4 L192 2TL1-5 MS24524-31 E, F, K, L, M, N MS24659-31
1-2, 4-5* OFF 2-3, 5-6* 4 L192 2TL1-7 MS24524-27 E, L, N MS24659-27
None** OFF 2-3, 5-6 3 L191 2TL1-21 MS24524-24 E, F, K, M MS24659-24
None** 1-2, 4-5 2-3, 5-6 3 L191 2TL1-31 MS24524-33 E, F, K, M MS24659-33
None** 1-2, 4-5 2-3, 5-6* 4 L192 2TL1-51 MS24524-32 E MS24659-32
1-2, 4-5* OFF None** 4 L192 2TL1-61 MS24524-28 E MS24659-28
1-2, 4-5 1-2, 5-6 2-3, 5-6 3 L191 2TL1-10 MS27407-4 ALL TYPES MS27408-4
1-2, 4-5* 1-2, 5-6 2-3, 5-6 4 L192 2TL1-50 MS27407-5 E, F, K, L, M, N MS27408-5
1-2, 4-5* 1-2, 5-6 2-3, 5-6* 4 L192 2TL1-70 MS27407-6 E, L, N MS27408-6
4 1-2, 4-5 OFF 2-3, 5-6 5 L191 4TL1-1 MS24525-21 ALL TYPES MS24660-21
7-8, 10-11 8-9, 11-12
1-2, 4-5 OFF 2-3, 5-6 6 L192 4TL1-5 MS24525-31 E, F, K, L, M, N MS24660-31
7-8, 10-11* 8-9, 11-12
1-2, 4-5 OFF 2-3, 5-6 6 L192 4TL1-7 MS24525-27 E, L, N MS24660-27
7-8, 10-11* 8-9, 11-12*
None** OFF 2-3, 5-6 5 L191 4TL1-21 MS24525-24 E, F, K, M MS24660-24
8-9, 11-12
None** 1-2, 4-5 2-3, 5-6 5 L191 4TL1-31 MS24525-33 E, F, K, M MS24660-33
7-8, 10-11 8-9, 11-12
None** 1-2, 4-5 2-3, 5-6 6 L192 4TL1-51 MS24525-32 E MS24660-32
7-8, 10-11 8-9, 11-12*
1-2, 4-5 OFF None** 6 L192 4TL1-61 MS24525-28 E MS24660-28
7-8, 10-11*
1-2, 4-5 2-3, 4-5 2-3, 5-6 5 L191 4TL1-10 ALL TYPES
7-8, 10-11 8-9, 11-12
1-2, 4-5 2-3, 4-5 2-3, 5-6 6 L192 4TL1-50 MS27406-2 E, F, K, L, M, N MS27409-2
7-8, 10-11* 7-8, 11-12 8-9, 11-12
1-2, 4-5 2-3, 4-5 2-3, 5-6 6 L192 4TL1-70 E, L, N
7-8, 10-11* 8-9, 11-12*
1-2, 4-5 2-3, 4-5 2-3, 5-6 5 L191 4TL1-12 MS27406-1 ALL TYPES MS27409-1
7-8, 10-11 7-8, 11-12 8-9, 11-12
1-2, 4-5 2-3, 4-5 2-3, 5-6 6 L192 4TL1-72 MS27406-3 E, L, N MS27409-3
7-8, 10-11* 7-8, 11-12 8-9, 11-12*
* These positions only are momentary. All others are maintained.
** Togglelever is blocked from thesepositions. Togglebecomes two position, with centerbeing oneextreme
position.
*** Also add appropriate suffix letter to the Military Number.
SOLDER TURRET TERMINAL VERSION HOW TO ORDER
11TL, 12TL, and 14TL type switches with
solder turret terminals are qualified to
MIL-S-3950.They have thesamecircuitry
and electrical ratings as their 1TL, 2TL,
and 4TL counterparts. For example,
11TL1-2 is the same as 1TL1-2, except it
has solder turret terminals instead of
screw terminals. The complete MS draw-
ingnumbersareshownindatasheet204.
Circuitry Type Std. Lever Lever Lock
One Pole 11TL MS27734 MS27737
Two Pole 12TL MS27735 MS27738
Four Pole 14TL MS27736 MS27739
Manual Switches TL Series
Environment-Sealed Toggle Switches/IWTS
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada43
GENERAL INFORMATION
IWTS (Integrated Wire Termination Sys-
tem) provides you with a reliable, com-
pletely serviceable unit which meets MIL-
S-3950 requirements. IWTS improves
maintainabilitysincewiringbundlesneed
not be disturbed. Leads are quickly and
easily assembled or removed with an in-
sert-extract tool.
A unique three-rib (grommet style) elas-
tomer seal protects the lead connections
without potting. There are no exposed
metal terminals.
Versionsareavailable thatwill acceptNo.
16wirewithM39029/1-102 contactpinsor
No. 20 wire with M39029/1-101 contact
pins. Connections are resistant to shock,
vibration, and high pulling force.
TYPICAL APPLICATIONS
1
Military and civilian aircraft and marine
navigational equipment
1
Command and control systems
1
Radar and air defense systems
1
Test, ground support, and training
equipment
1
Tanks, armored personnel carriers,
and other military vehicles
POSSIBLE VARIATIONS
In addition to the contact arrangements
shown in the order guide, IWTS switches
can be furnished with all the Series TL
combinations shown in order guides on
the previous pages.
Pull-to-unlock toggle lever versions can
be made available. Contact the 800 num-
ber.
SPECIAL TL LEVERS
Some of the lever variations available for
TL toggle switches are shown below.
They can also have the same colored tab
leversfurnished withTWtoggleswitches.
For further information, contact the 800
number.
Manuals
Manual Switches TL Series
Environment-Sealed Toggle Switches
44HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
TL 2-POSITION VERSIONS WITH IWTS TERMINATION ORDER GUIDE
Circuit(s) Made With
Toggle At: Page 39 No. 16 Termination No. 20 Termination
No.
Poles Keyway
Position Opposite
Keyway
Electrical
Rating
Code
UL/CSA
Rating
Code Catalog
Listing MIL
Part No. Catalog
Listing MIL
Part No.
1 OFF 2-3 1 L191 101TL1-2 MS27722-22 101TL2-2 MS27784-22
OFF* 2-3 2 L192 101TL1-4 MS27722-29 101TL2-4 MS27784-29
1-2* OFF 2 L192 101TL1-6 MS27722-30 101TL2-6 MS27784-30
1-2 2-3 1 L191 101TL1-3 MS27722-23 101TL2-3 MS27784-23
1-2* 2-3 2 L192 101TL1-8 MS27722-26 101TL2-8 MS27784-26
2 OFF 2-3, 5-6 3 L191 102TL1-2 MS27723-22 102TL2-2 MS27785-22
OFF* 2-3, 5-6 4 L192 102TL1-4 MS27723-29 102TL2-4 MS27785-29
1-2, 4-5* OFF 4 L192 102TL1-6 MS27723-30 102TL2-6 MS27785-30
1-2, 4-5 2-3, 5-6 3 L191 102TL1-3 MS27723-23 102TL2-3 MS27785-23
1-2, 4-5* 2-3, 5-6 4 L192 102TL1-8 MS27723-26 102TL2-8 MS27785-26
4 OFF 2-3, 5-6 5 L191 104TL1-2 MS27724-22 104TL2-2 MS27786-22
8-9, 11-12
OFF* 2-3, 5-6 6 L192 104TL1-4 MS27724-29 104TL2-4 MS27786-29
8-9, 11-12
1-2, 4-5 OFF 6 L192 104TL1-6 MS27724-30 104TL2-6 MS27786-30
7-8, 10-11*
1-2, 4-5 2-3, 5-6 5 L191 104TL1-3 MS27724-23 104TL2-3 MS27786-23
7-8, 10-11 8-9, 11-12
1-2, 4-5 2-3, 5-6 6 L192 104TL1-8 MS27724-26 104TL2-8 MS27786-26
7-8, 10-11* 8-9, 11-12
TL 3-POSITION VERSIONS WITH IWTS TERMINATION ORDER GUIDE
Circuit(s) Made With Toggle At: No. 16 Termination No. 20 Termination
No. Keyway Center Opposite Electrical
Rating UL/CSA
Rating Catalog MIL Catalog MIL
Poles Position Position Keyway Code Code Listing Part No. Listing Part No.
1 1-2 OFF 2-3 1 L191 101TL1-1 MS27722-21 101TL2-1 MS27784-21
1-2* OFF 2-3 2 L192 101TL1-5 MS27722-31 101TL2-5 MS27784-31
1-2* OFF 2-3* 2 L192 101TL1-7 MS27722-27 101TL2-7 MS27784-27
2 1-2, 4-5 OFF 2-3, 5-6 3 L191 102TL1-1 MS27723-21 102TL2-1 MS27785-21
1-2, 4-5* OFF 2-3, 5-6 4 L192 102TL1-5 MS27723-31 102TL2-5 MS27785-31
1-2, 4-5* OFF 2-3, 5-6* 4 L192 102TL1-7 MS27723-27 102TL2-7 MS27785-27
4 1-2, 4-5 OFF 2-3, 5-6 5 L191 104TL1-1 MS27724-21 104TL2-1 MS27786-21
7-8, 10-11 8-9, 11-12
1-2, 4-5 OFF 2-3, 5-6 6 L192 104TL1-5 MS27724-31 104TL2-5 MS27786-31
7-8, 10-11* 8-9, 11-12
1-2, 4-5 OFF 2-3, 5-6 6 L192 104TL1-7 MS27724-27 104TL2-7 MS27786-27
7-8, 10-11* 8-9, 11-12*
* These positions only are momentary. All others are maintained.
Manual Switches TL Series
Environment-Sealed Toggle Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada45
MOUNTING DIMENSIONS (For reference only)
Standard toggle lever Pull-to-unlock toggle lever
One pole Two pole Four pole
Standard toggle lever, IWTS termination
Note:
Terminal screws and mounting hardware
(locking ring, lockwasher, and two hexnuts)
are furnished unassembled.
Panel cutout
With locking ring Without locking ring
Note:
1,4/.06 Min deep to accommodate locking ring. (15PA87 panel seal
requires blind hole to insure seal integrity.)
Manuals
Manual Switches TP Series
Environment-Sealed Rocker Switches
46HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
Above panel Flush panel
ELECTRICAL RATINGS
(In amperes)
115 Volts AC
Elec. 28 Volts DC 115 VDC 250 VDC 60 & 400 HZ 230 VAC
Rating
Code Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res.
1 15 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
4 10 18 5 0.75 0.5 8 11 2 6
5 12 20 5 0.75 0.5 15 15 4 6
6 10 18 4 0.75 0.5 8 11 2 6
UL/CSA Rating Code Electrical Rating
L192 10 amps-125, 250, 277 VAC; 14Hp-125 VAC; 12Hp-250, 277 VAC
3 Amps-125 VAC
‘‘
L’’
L191 15 amps-125, 250, 277 VAC: 12Hp-125 VAC; 1Hp-250, 277 VAC
5 amps-125 VAC
‘‘
L’’
ApplicationNote:HoneywellMICROSWITCHdoes
not
recommendtheuseofsilver
cadium oxide switch contacts in non-arcing loads. Non-arcing loads are generally
loads less than 12 volts and/or 0.5 amp. TP switches use silver cadmium oxide con-
tacts.Ifyouhavespecificquestions,contacttheMICROSWITCHApplicationCenterat
1-800-537-6945.
FEATURES
1
2 and 3 position pushbutton action
1
Various button colors
1
1, 2, and 4 pole circuitry
1
Flushpanelandabovepanelmounting
1
Temperature range is from –65Fto
+160F (–54Cto+71C)
1
UL recognized, CSA certified
CONSTRUCTION
Above panel mounting gives a distinct
button appearance. Flush panel mount-
ing presents a low button profile.
TERMINAL CIRCUIT
IDENTIFICATION
Terminal identifications are referred to in
theorderguidestoindicatewhichcircuits
aremadeineachtoggleposition(i.e.,1-2
indicates circuit closure through termi-
nals1and 2).
One pole
Two pole
Four pole
Manual Switches TP Series
Environment-Sealed Rocker Switches
Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-416-293-8111 Canada 47
Typical two-pole flush panel
translucent button switch
Typical one-pole above panel
transparent button switch
BUTTON OPTIONS
Buttons are removable and interchange-
able. They measure .87N×1.46N(22,1 ×
37,1mm).
Transparent (colorless plastic) buttons
accept under-the-surface legend inserts
for station and function identification.
Legendinsertsare notfurnished.Insert
legendingcanbedonebyyourlocalsup-
plier.
Translucent (white plastic) buttons have
a clear appearance.
Colored (opaque plastic) buttons are ex-
cellent for color coding switch functions.
LEGENDING
MICRO SWITCH provides hot stamp leg-
ending on the button face. Use TP Leg-
end Order Sheet FO-53730 (page 49) to
specifyyour needs.Additionalcopies are
available from your nearest MICRO
SWITCH Sales Office. (MICRO SWITCH
does not provide legending service on
legend inserts.)
Translucent and opaque buttons may al-
so be engraved and filled by the user.
SWITCHES WITHOUT BUTTONS
To order switches without buttons, con-
vert catalog listings shown in the order
guides. Substitute TP7 for TP4 and TP16
above panel mounted switches; substi-
tute TP8 for TP201 and TP12 flush panel
mounted switches. Order buttons sepa-
rately from the chart below.
BUTTON ORDER GUIDE
Color Catalog Listing
Translucent 12PA6
Transparent 12PA4
White* 12PA5-W
Yellow* 12PA5-Y
Black* 12PA5-BK
Green* 12PA5-G
Red* 12PA5-R
Blue* 12PA5-BL
* Opaque
TP 2-POSITION ORDER GUIDE Furnished with buttons.
Catalog Listings
Circuits Made With Button At: Flush Panel Above Panel
UL/CSA Elec.
No. of Ident. Opposite Rating Rating Translucent Transparent Translucent Transparent
Poles Lug Position Ident. Lug Code Code Button Button Button Button
1 OFF 2-3 L191 1 1TP201-2 1TP12-2 1TP216-2 1TP4-2
OFF* 2-3 L192 2 1TP201-4 1TP12-4 1TP216-4 1TP4-4
1-2* OFF L192 2 1TP201-6 1TP12-6 1TP216-6 1TP4-6
1-2 2-3 L191 1 1TP201-3 1TP12-3 1TP216-3 1TP4-3
1-2* 2-3 L192 2 1TP201-8 1TP12-8 1TP216-8 1TP4-8
2 OFF 2-3, 5-6 L191 3 2TP201-2 2TP12-2 2TP216-2 2TP4-2
OFF* 2-3, 5-6 L192 4 2TP201-4 2TP12-4 2TP216-4 2TP4-4
1-2,4-5* OFF L192 4 2TP201-6 2TP12-6 2TP216-6 2TP4-6
1-2,4-5 2-3, 5-6 L191 3 2TP201-3 2TP12-3 2TP216-3 2TP4-3
1-2,4-5* 2-3, 5-6 L192 4 2TP201-8 2TP12-8 2TP216-8 2TP4-8
4 OFF 2-3, 5-6, 8-9, 11-12 L191 5 4TP201-2 4TP12-2 4TP4-2
OFF* 2-3, 5-6, 8-9, 11-12 L192 6 4TP201-4 4TP12-4 4TP216-4 4TP4-4
1-2, 4-5, 7-8, 10-11* OFF L192 6 4TP201-6 4TP12-6
1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 L191 5 4TP201-3 4TP12-3 4TP216-3 4TP4-3
1-2, 4-5, 7-8, 10-11* 2-3, 5-6, 8-9, 11-12 L192 6 4TP201-8 4TP12-8 4TP216-8
* These positions only are momentary. All others are maintained.
Manuals
Manual Switches TP Series
Environment-Sealed Rocker Switches
48 Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-416-293-8111 Canada
TP 3-POSITION ORDER GUIDE Furnished with buttons.
Catalog Listings
Circuits Made With Button At: Flush Panel Above Panel
UL/CSA Elec.
No. of Ident. Lug Center Opposite Lug Rating Rating Translucent Transparent Translucent Transparent
Poles Position Position Position Code Code Button Button Button Button
1-2 OFF 2-3 L191 1 1TP201-1 1TP12-1 1TP216-1 1TP4-1
1-2* OFF 2-3 L192 2 1TP201-5 1TP12-5 1TP216-5 1TP4-5
1-2* OFF 2-3* L192 2 1TP201-7 1TP12-7 1TP216-7 1TP4-7
1 NONE** OFF 2-3* L191 1 1TP201-21 1TP12-21 1TP4-21
NONE** 1-2 2-3 L191 1 1TP201-31 1TP12-31 1TP4-31
NONE** 1-2 2-3* L192 2 1TP201-51 1TP12-51 1TP216-51 1TP4-51
1-2* OFF NONE** L192 2 1TP201-61 1TP12-61 1TP216-61 1TP4-61
1-2, 4-5 OFF 2-3, 5-6 L191 3 2TP201-1 2TP12-1 2TP216-1 2TP4-1
1-2, 4-5* OFF 2-3, 5-6 L192 4 2TP201-5 2TP12-5 2TP216-5 2TP4-5
1-2, 4-5* OFF 2-3, 5-6* L192 4 2TP201-7 2TP12-7 2TP216-7 2TP4-7
NONE** OFF 2-3, 5-6 L191 3 2TP201-21 2TP12-21 2TP216-21 2TP4-21
2 NONE** 1-2, 4-5 2-3, 5-6 L191 3 2TP201-31 2TP12-31 2TP216-31 2TP4-31
NONE** 1-2, 4-5 2-3, 5-6* L192 4 2TP201-512 2TP12-512 2TP216-512 2TP4-512
1-2, 4-5* OFF NONE** L192 4 2TP201-61 2TP12-61 2TP216-61 2TP4-61
1-2, 4-5 1-2, 5-6 2-3, 5-6 L191 3 2TP201-10 2TP12-10 2TP216-10 2TP4-10
1-2, 4-5* 1-2, 5-6 2-3, 5-6 L192 4 2TP201-50 2TP12-50 2TP216-50 2TP4-50
1-2, 4-5* 1-2, 5-6 2-3, 5-6* L192 4 2TP201-70 2TP12-70 2TP216-70 2TP4-70
1-2, 4-5, OFF 2-3, 5-6 L191 5 4TP201-1 4TP12-1 4TP216-1 4TP4-1
7-8, 10-11 8-9, 11-12
1-2, 4-5 OFF 2-3, 5-6 L192 6 4TP201-5 4TP12-5 4TP4-5
7-8, 10-11* 8-9, 11-12
1-2, 4-5, OFF 2-3, 5-6 L192 6 4TP201-7 4TP12-7 4TP216-7 4TP4-7
7-8, 10-11* 8-9, 11-12*
NONE** OFF 2-3, 5-6, L191 5 4TP201-21 4TP12-21 4TP216-21 4TP4-21
8-9, 11-12
4 NONE** 1-2, 4-5 2-3, 5-6, L191 5 4TP201-31 4TP216-31 4TP4-31
7-8, 10-11 8-9, 11-12
NONE** 1-2, 4-5 2-3, 5-6 L192 6 4TP201-51 4TP216-51 4TP4-51
7-8, 10-11 8-9, 11-12*
1-2, 4-5, OFF NONE** L192 6 4TP201-61 4TP12-61 4TP216-61 4TP4-61
7-8, 10-11*
1-2, 4-5, 2-3, 4-5 2-3, 5-6, L191 5 4TP201-10 4TP12-10 4TP4-10
7-8, 10-11 8-9, 11-12
1-2, 4-5, 2-3, 4-5 2-3, 5-6, L192 6 4TP201-50 4TP12-50 4TP216-50 4TP4-50
7-8, 10-11* 7-8, 11-12 8-9, 11-12
1-2, 4-5, 2-3, 4-5 2-3, 5-6, L192 6 4TP201-70 4TP12-70 4TP216-70 4TP4-70
7-8, 10-11* 8-9, 11-12*
* These positions only are momentary. All others are maintained.
** Operator is blocked from these positions. Switch becomes two position, with center being one extreme position.
Special on-on-on circuitry. See page 40.
This Page Intentionally Left Blank
Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-416-293-8111 Canada 49
Manual Switches TP Series
Environment-Sealed Rocker Switches
50 Honeywell1MICRO SWITCH Sensing and Control11-800-537-6945 USA1 F1-815-235-6847 International11-416-293-8111 Canada
MOUNTING DIMENSIONS (For reference only)
4-POLE HAS 6-32 UNC-28 THREAD LOCKNUT
Panel cutout One pole
Two pole
Four pole
Manual Switches TW Series
Miniature Toggle Switches
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada59
11TW Standard toggle lever 1TW Standard unsealed toggle lever
1532Nbushing 14Nbushing
12TW Pull-to-unlock toggle lever 2TW101 Standard sealed toggle lever
1532Nbushing 14Nbushing
FEATURES
1
Qualified to MIL-S-83731
1
Save space and weight
1
SPDT and DPDT circuitry
1
Choice of 14Nor 1532Nbushings
1
1532Nbushing has lever seal
1
Pull-to-unlock option on 1532Nbushing
1
UL recognized
1
Temperature range: –85Fto+160F
(–65Cto+71C)
1
Sealed bushing versions
GENERAL INFORMATION
Molded-interminals areplatedfor solder-
ing. There is positive return on momenta-
ryversions.Allswitchescomewithalock-
washer, a keying washer, and two hex-
nuts. Special ‘‘on-on-on’’ circuitries,
similar to those shown for TL, are also
available for TW.
CIRCUITRY
11Single Pole Double Throw
21Two Single Pole
Double Throw Circuits
1Refer to order guides.
ELECTRICAL RATINGS
Amperes
Volts Resistive Inductive Lamp
30 VDC 5 2 1
115 VAC 5 2 1
UL Code 117 5 amps @ 125 VAC
TERMINAL CIRCUIT
IDENTIFICATIONS
Terminal identifications are referred to in
the Ordering Charts to indicate which cir-
cuits are made in each toggle position
(i.e., ‘‘1-2’’ reference indicates circuit clo-
sure through terminals1and 2).
Manuals
Manual Switches TW Series
Miniature Toggle Switches
60 HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
TW 2-POSITION ORDER GUIDES
Switches with 1532NBushings
Circuits Made With Toggle At: Sealed Standard Toggle Sealed Pull-to-Unlock Toggle**
No. Keyway Opposite Catalog Military Add Suffix to Military
Poles Position Keyway Listing No. Standard Listing No.**
1 OFF 2-3 ON 11TW1-2 MS27718-22-1 D, F, G MS27720-22-1
1 2-1 ON 2-3 ON 11TW1-3 MS27718-23-1 D, F, G MS27720-23-1
1 2-1 ON* 2-3 ON 11TW1-8 MS27718-26-1 F MS27720-26-1
2 OFF 2-3 & 5-6 ON 12TW1-2 MS27719-22-1 D, F, G MS27721-22-1
2 2-1 & 5-4 ON 2-3 & 5-6 ON 12TW1-3 MS27719-23-1 D, F, G MS27721-23-1
2 2-1 & 5-4 ON* 2-3 & 5-6 ON 12TW1-8 MS27719-26-1 F MS27721-26-1
* These positions are momentary. All others are maintained.
** Also add appropriate suffix letter to the Military Number.
Switches with 14NBushings
Circuits Made With Toggle At: Unsealed Standard Toggle Sealed Standard Toggle
No. Keyway Opposite Catalog Military
Poles Position Keyway Listing No. Catalog Listing
1 OFF 2-3 ON 1TW1-2 MS27716-22-1 1TW101-2
1 2-1 ON 2-3 ON 1TW1-3 MS27716-23-1 1TW101-3
1 2-1 ON* 2-3 ON 1TW1-8 MS27716-26-1 1TW101-8
2 OFF 2-3 & 5-6 ON 2TW1-2 MS27717-22-1 2TW101-2
2 2-1 & 5-4 ON 2-3 & 5-6 ON 2TW1-3 MS27717-23-1 2TW101-3
2 2-1 & 5-4 ON* 2-3 & 5-6 ON 2TW1-8 MS27717-26-1 2TW101-8
* These positions are momentary. All others are maintained.
TW 3-POSITION ORDER GUIDES
Switches with 1532NBushings
Circuits Made With Toggle At: Sealed Standard Toggle Sealed Pull-to-Unlock Toggle
No. Keyway Center Opposite Catalog Military Add Suffix to Military
Poles Position Position Keyway Listing No. Standard Listing No.**
1 2-1 ON OFF 2-3 ON 11TW1-1 MS27718-21-1 ALL MS27720-21-1
1 2-1 ON* OFF 2-3 ON 11TW1-5 MS27718-31-1 E, F, K, L, M, N MS27720-31-1
1 2-1 ON* OFF 2-3 ON* 11TW1-7 MS27718-27-1 E, L, N MS27720-27-1
2 2-1 & 5-4 ON OFF 2-3 & 5-6 ON 12TW1-1 MS27719-21-1 ALL MS27721-21-1
2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON 12TW1-5 MS27719-31-1 E, F, K, L, M, N MS27721-31-1
2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON* 12TW1-7 MS27719-27-1 E, L, N MS27721-27-1
* These positions only are momentary. All others are maintained.
** Also add appropriate suffix letter to the Military Number.
Switches with 14NBushings
Circuits Made With Toggle At: Unsealed Standard Toggle Sealed Standard Toggle
No. Keyway Center Opposite Catalog Military
Poles Position Position Keyway Listing No. Catalog Listing
1 2-1 ON OFF 2-3 ON 1TW1-1 MS27716-21-1 1TW101-1
1 2-1 ON* OFF 2-3 ON 1TW1-5 MS27716-31-1 1TW101-5
1 2-1 ON* OFF 2-3 ON* 1TW1-7 MS27716-27-1 1TW101-7
2 2-1 & 5-4 ON OFF 2-3 & 5-6 ON 2TW1-1 MS27717-21-1 2TW101-1
2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON 2TW1-5 MS27717-31-1 2TW101-5
2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON* 2TW1-7 MS27717-27-1 2TW101-7
* These positions are momentary. All others are maintained.
Manual Switches TW Series
Miniature Toggle Switches (IWTS)
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada61
LOCKING CONFIGURATIONS
When ordering pull-to-unlock toggle list-
ings, add the suffix letter shown in this
chart to the standard toggle catalog list-
ing and the Military Approval number.
ABDEFGH
Locked In Locked Out Of
Center and Locked Out Locked In Locked In Center And
Locked In Extreme Position Of Center Locked In Extreme Position Extreme Position Extreme Position
Three Positions (Keyway Side) Position Center Position (Opposite Keyway) (Keyway Side) (Keyway Side)
JKLMNP
Locked Out Of Locked In Locked Out Of Locked Out Of
Center And Center And Locked Out Of And Into Locked Out Of And Into
Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position
(Opposite Keyway) (Opposite Keyway) (Keyway Side) (Opposite Keyway) (Opposite Keyway) (Keyway Side)
WITH IWTS TERMINATION
1
1532Nbushing has lever seal
1
One or two pole circuitry
1
Accepts #20 wire using M39029/1-101
contact pins
1
Connections resist shock, vibration,
and high pulling force
TW 2-POSITION ORDER GUIDE IWTS TERMINATION
Circuits Made With Toggle At: Standard Toggle Pull-to-Unlock Toggle
No. Add Suffix to
Poles Keyway Position Opposite Keyway Catalog Listing Standard Listing
1 2-1 ON 2-3 ON 111TW1-3 D, F, G
1 2-1 ON* 2-3 ON 111TW1-8 F
2 2-1 & 5-4 ON 2-3 & 5-6 ON 112TW1-3 D, F, G
2 2-1 & 5-4 ON* 2-3 & 5-6 ON 112TW1-8 F
TW 3-POSITION ORDER GUIDE IWTS TERMINATION
Circuits Made With Toggle At: Standard Toggle Pull-to-Unlock Toggle
No. Add Suffix to
Poles Keyway Position Center Position Opposite Keyway Catalog Listing Standard Listing
1 2-1 ON OFF 2-3 ON 111TW1-1 ALL
1 2-1 ON* OFF 2-3 ON 111TW1-5 E, F, K, L, M, N
1 2-1 ON* OFF 2-3 ON* 111TW1-7 E, L, N
2 2-1 & 5-4 ON OFF 2-3 & 5-6 ON 112TW1-1 ALL
2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON 112TW1-5 E, F, K, L, M, N
2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON* 112TW1-7 E, L, N
* These positions only are momentary. All others are maintained.
Manuals
Manual Switches TW Series
Miniature Toggle Switches
62Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
WITH COLORED TAB LEVERS
1
Available in seven colors
1
Affords attractive front-of-panel ap-
pearance for graphic display and func-
tional identify
1
Levers made to withstand temper-
atures up to160F(71C)
1
Switches furnished with decorative
knurled nut, a lockwasher, a keying
washer, and a hex nut
1
1532Nbushing/sealed lever
1
Available in IWTS termination versions
TW ORDER GUIDE
To order, combine the basic (function)
listing from Table 1with the desired lever
color suffix from Table 2.
TABLE 1 TOGGLE POSITION AND CONTACT ARRANGEMENT
Circuits Made With Toggle At:
Positions No. Poles Keyway Position Center Position Opposite Keyway
Basic Listing
Color Suffix
See Table 2
2 1 OFF NONE 2-3 ON 11TW19-2————
2 1 2-1 ON NONE 2-3 ON 11TW19-3————
2 1 2-1 ON* NONE 2-3 ON 11TW19-8————
2 2 OFF NONE 2-3 & 5-6 ON 12TW19-2————
2 2 2-1 & 5-4 NONE 2-3 & 5-6 ON 12TW19-3————
2 2 2-1 & 5-4* NONE 2-3 & 5-6 ON 12TW19-8————
3 1 2-1 ON OFF 2-3 ON 11TW19-1————
3 1 2-1 ON* OFF 2-3 ON 11TW19-5————
3 1 2-1 ON* OFF 2-3 ON* 11TW19-7————
3 2 2-1 & 5-4 ON OFF 2-3 & 5-6 ON 12TW19-1————
3 2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON 12TW19-5————
3 2 2-1 & 5-4 ON* OFF 2-3 & 5-6 ON* 12TW19-7————
* These positions only are momentary. All others are maintained.
TABLE2—TABLEVER COLORS
Light
Tab Lever Color White Black Blue Red Green Orange Gray
Color suffix A001 A002 A003 A004 A005 A006 A007
TW SWITCHES WITH SPECIAL CIRCUITRIES ORDER GUIDE
All 2-pole 3-position TW switches are available with special ‘‘on-on-on’’ 10, 50, 70 circuitry options as shown below.
Unsealed Sealed
2-Pole 3-Position Switches Sealed Standard Toggle Std. Toggle Tab Lever
Circuits Made With Toggle At: 15/32Nbushing 1/4Nbushing 1/4Nbushing 15/32Nbushing
Keyway Center Opposite Catalog Catalog Catalog Catalog
Position Position Keyway Listing Listing Listing Listing
2-1 & 5-4 ON 2-1 & 5-6 ON 2-3 & 5-6 ON 12TW1-10 2TW101-10 2TW1-10 12TW19-10————
2-1 & 5-4 ON* 2-1 & 5-6 ON 2-3 & 5-6 ON 12TW1-50 2TW101-50 2TW1-50 12TW19-50————
2-1 & 5-4 ON* 2-1 & 5-6 ON 2-3 & 5-6 ON* 12TW1-70 2TW101-70 2TW1-70 12TW19-70————
* These positions are momentary. All others are maintained.
Manual Switches TW Series
Miniature Toggle Switches
Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada63
MOUNTING DIMENSIONS (For reference only)
Mounting detail for 14Nbushing switches Dimensions for 14Nbushing switches
Without locking ring With locking ring
Mounting detail for 1532 Nbushing switches
With locking ring Without locking ring
Note: 1,1/.05 MIN. DEEP TO ACCOMMODATE LOCKING RING.
FOR SWITCHES USING PANEL SEAL, DO NOT ALLOW THRU HOLE
MOUNTING.
Key: 0,0 Jmm
0.00 Jinches
Dimensions for 1532Nswitches
Standard toggle lever Pull-to-unlock toggle lever
Manuals
Manual Switches TS Series
Toggle Switches
64 Honeywell1SensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
2-pole shown
MOUNTING DIMENSIONS
1-pole 2-pole
FEATURES
1
2 or 3-position, momentary and main-
tained action
1
1and 2-pole circuitry
1
Rated up to15 amps
1
Lever-to-bushing seal
1
Solder, screw, or quick-connect
terminals
1
UL recognized, CSA certified
Colored tab levers and special ‘‘on-on-
on’’ circuitry can also be furnished.
TERMINAL CIRCUIT
IDENTIFICATION
Terminal identifications in the order
guidesindicatewhichcircuitsaremadein
each position (i.e., 1-2 indicates circuit
closure through terminals1and 2).
ELECTRICAL RATINGS
Rating
Code UL/CSA Rating
L192 10 Amps, 125, 250, 277 VAC
14HP, 125 VAC
12HP, 250, 277 VAC
3 Amps, 125 VAC
‘‘
L’’
L191 15 Amps, 125, 250, 277 VAC
12HP, 125 VAC
1 HP, 250, 277 VAC
5 Amps, 125 VAC (L)
NOTE: Application Note on Page 57 ap-
plies to TS switches.
TS 2-POSITION ORDER GUIDE
Circuit(s) Made With Toggle At: UL/CSA
Keyway Opposite Rating Screw Solder Quick-Connect
No. Of Poles Position Keyway Code Terminals Terminals Terminals
1 OFF 2-3 ON L191 11TS15-2 11TS115-2 11TS95-2
2-1 ON 2-3 ON L191 11TS15-3 11TS115-3 11TS95-3
OFF*2-3ONL19211TS15-4 11TS95-4
2-1 ON* OFF L192 11TS15-6 11TS115-6 11TS95-6
2-1ON*2-3ONL19211TS15-811TS115-8
2 OFF 2-3 & 5-6 ON L191 12TS15-2 12TS115-2 12TS95-2
2-1 & 5-4 ON 2-3 & 5-6 ON L191 12TS15-3 12TS115-3 12TS95-3
OFF*2-3&5-6ONL19212TS15-4
2-1&5-4ON*OFFL19212TS15-6
2-1&5-4ON*2-3&5-6ONL19212TS15-812TS115-8
TS 3-POSITION ORDER GUIDE
Circuit(s) Made With Toggle At: UL/CSA
Keyway Center Opposite Rating Screw Solder Quick-Connect
No. Of Poles Position Position Keyway Code Terminals Terminals Terminals
1 2-1 ON OFF 2-3 ON L191 11TS15-1 11TS115-1 11TS95-1
2-1 ON* OFF 2-3 ON L192 11TS15-5 11TS115-5 11TS95-5
2-1 ON* OFF 2-3 ON* L192 11TS15-7 11TS115-7 11TS95-7
2 2-1 & 5-4 ON OFF 2-3 & 5-6 ON L191 12TS15-1 12TS115-1 12TS95-1
2-1 & 5-4 ON* OFF 2-3 & 5-6 ON L192 12TS15-5 12TS115-5 12TS95-5
2-1&5-4ON*OFF2-3&5-6ON*L19212TS15-7 12TS95-7
2-1&5-4ON2-1&5-6ON2-3&5-6ONL191 12TS95-10
* Marked toggle positions are momentary. All other positions are maintained.
Manual Switches TS Series
Toggle Switches
64 HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
2-pole shown
MOUNTING DIMENSIONS
1-pole 2-pole
FEATURES
1
2 or 3-position, momentary and main-
tained action
1
1and 2-pole circuitry
1
Rated up to15 amps
1
Lever-to-bushing seal
1
Solder, screw, or quick-connect
terminals
1
UL recognized, CSA certified
Colored tab levers and special ‘‘on-on-
on’’ circuitry can also be furnished.
TERMINAL CIRCUIT
IDENTIFICATION
Terminal identifications in the order
guidesindicatewhichcircuitsaremadein
each position (i.e., 1-2 indicates circuit
closure through terminals1and 2).
ELECTRICAL RATINGS
Rating
Code UL/CSA Rating
L192 10 Amps, 125, 250, 277 VAC
14HP, 125 VAC
12HP, 250, 277 VAC
3 Amps, 125 VAC
‘‘
L’’
L191 15 Amps, 125, 250, 277 VAC
12HP, 125 VAC
1 HP, 250, 277 VAC
5 Amps, 125 VAC (L)
NOTE: Application Note on Page 57 ap-
plies to TS switches.
TS 2-POSITION ORDER GUIDE
Circuit(s) Made With Toggle At: UL/CSA
Keyway Opposite Rating Screw Solder Quick-Connect
No. Of Poles Position Keyway Code Terminals Terminals Terminals
1 OFF 2-3 ON L191 11TS15-2 11TS115-2 11TS95-2
2-1 ON 2-3 ON L191 11TS15-3 11TS115-3 11TS95-3
OFF*2-3ONL19211TS15-4 11TS95-4
2-1 ON* OFF L192 11TS15-6 11TS115-6 11TS95-6
2-1ON*2-3ONL19211TS15-811TS115-8
2 OFF 2-3 & 5-6 ON L191 12TS15-2 12TS115-2 12TS95-2
2-1 & 5-4 ON 2-3 & 5-6 ON L191 12TS15-3 12TS115-3 12TS95-3
OFF*2-3&5-6ONL19212TS15-4
2-1&5-4ON*OFFL19212TS15-6
2-1&5-4ON*2-3&5-6ONL19212TS15-812TS115-8
TS 3-POSITION ORDER GUIDE
Circuit(s) Made With Toggle At: UL/CSA
Keyway Center Opposite Rating Screw Solder Quick-Connect
No. Of Poles Position Position Keyway Code Terminals Terminals Terminals
1 2-1 ON OFF 2-3 ON L191 11TS15-1 11TS115-1 11TS95-1
2-1 ON* OFF 2-3 ON L192 11TS15-5 11TS115-5 11TS95-5
2-1 ON* OFF 2-3 ON* L192 11TS15-7 11TS115-7 11TS95-7
2 2-1 & 5-4 ON OFF 2-3 & 5-6 ON L191 12TS15-1 12TS115-1 12TS95-1
2-1 & 5-4 ON* OFF 2-3 & 5-6 ON L192 12TS15-5 12TS115-5 12TS95-5
2-1&5-4ON*OFF2-3&5-6ON*L19212TS15-7 12TS95-7
2-1&5-4ON2-1&5-6ON2-3&5-6ONL191 12TS95-10
* Marked toggle positions are momentary. All other positions are maintained.
Manual Switches AT Series
Toggle Switch Assemblies
Honeywell1MICROSWITCHSensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada131
6AT SERIES FEATURES
12-position, momentary and
maintained action.
11, 2 or 3 SPDT precision basic
switches.
1Short behind-panel depth.
1Choice of 14or 1532-inch bushings.
1Silver or gold contacts.
1UL recognized, CSA certified basic
switches.
ELECTRICAL RATINGS Basic Switches
30 VDC Rating
Amps
UL/CSA Rating Load Sea Level 50,000 ft.
Silver 5 amps, Inductive 3 2.5
Contacts 125-250 VAC Resistive 5 5
Max. Inrush 24 24
Gold 1 amp, Inductive 0.5 0.5
Contacts 125 VAC Resistive 1 1
Max. Inrush 2 2
2-POSITION ORDER GUIDE
Toggle Lever Position Number
Mounting Opposite of Types Solder
‘‘
T’’
‘‘
T2’’
Style Keyway Keyway Poles Contacts Terminals Terminals Terminals
14
NBushing Maint. Maint. 1 Silver 6AT2 6AT2-T 6AT2-T2
With Key Tab 6AT68-T* 6AT68-T2*
Gold 6AT23 6AT23-T2
2 Silver 6AT3 6AT3-T 6AT3-T2
Gold 6AT13-T 6AT13-T2
3 Silver 6AT501 6AT501-T
14
NBushing Maint. Maint. 1 Silver 6AT1 6AT1-T 6AT1-T2
Without Key Tab
Gold 6AT56-T2
2 Silver 6AT4 6AT4-T2
14
NBushing Maint. Maint. 1 Silver 6AT201-T
With Key Washer
2 Gold 6AT231-T2
1532
NBushing Maint. Maint. 1 Silver 6AT6 6AT6-T 6AT6-T2
With Key Washer
Gold 6AT17 6AT17-T2
2 Silver 6AT7 6AT7-T
Gold 6AT42 6AT42-T2
3 Silver 6AT10 6AT10-T 6AT10-T2
Gold 6AT18 6AT18-T2
* Extra long toggle lever (.67N/17,0 mm).
Toggle/Rockers
Manual Switches AT Series
Toggle Switch Assemblies
134Honeywell1MICROSWITCHSensingandControl11-800-537-6945USA1F1-815-235-6847International11-800-737-3360Canada
MOUNTING DIMENSIONS (For reference only)
13/23AT
6AT PANEL CUTOUTS
14
NBushing
1532
NBushing
NOTE—
64AT300, 66AT300, and 68AT300 (M8805/98) listings have
a bushing seal and MS25196 panel seal.
Bushing mounting torque is10–15
in./lbs.
Manual Switches 23AT Series
Toggle Switch Assemblies
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada65
Standard lever Tab lever Pull-to-unlock
lever
FEATURES
1
2 or 3-position, momentary and main-
tained action.
1
2, 3 or 4 SPDT precision basic
switches.
1
Standard toggle, tab, or pull-to-unlock
levers.
1
Silver or gold contacts.
1
1532-inch bushing.
1
UL recognized, CSA certified basic
switches.
1
Lever-to-bushing seal option.
ELECTRICAL RATINGS Basic Switches
30 VDC Rating
Amps
UL/CSA Rating Load Sea Level 50,000 ft.
Silver 5 amps, Inductive 3 2.5
Contacts 125-250 VAC Resistive 5 5
Max. Inrush 24 24
Gold 1 amp, Inductive 0.5 0.5
Contacts 125 VAC Resistive 1 1
Max. Inrush 2 2
PULL-TO-UNLOCK TOGGLE LEVERS
As a guard against accidental operation,
pull-to-unlock toggle levers must be
pulled .090 inch/2,3 mm (approx.) to
change positions. A chart showing the13
locking configurations and their catalog
listing suffix code letters is shown on the
following page.
TERMINALS
‘‘T’’ ‘‘T2’’
AT 2-POSITION ORDER GUIDE
Standard Lever Tab Lever
Solder
Terminals ‘‘T’’
Terminals ‘‘T2’’
Terminals ‘‘T2’’
Terminals
Pull-To-Unlock Lever Solder
Terminals (Add locking letter
to catalog listings below)
Toggle Lever Position
Keyway Opposite
Keyway
No. of
Poles/
Switches Type
Contacts
Maint. Maint. 2 Silver 23AT1 23AT1-T 23AT1-T2 23AT402-T2 23AT1- Locking letters:
Gold 23AT11 23AT11-T2 23AT11- D, F, or G
3 Silver 23AT2 23AT2-T 23AT2-T2 23AT2-
Gold 23AT12 23AT12-T2 23AT12-
4 Silver 23AT3 23AT3-T 23AT3-T2 23AT3-
Gold 23AT8
Mom. Maint. 2 Silver 23AT4 23AT4-T 23AT4-T2 23AT403-T2
Gold 23AT19
3 Silver 23AT5
Gold
4 Silver 23AT6 23AT6-T2
Gold
AT MIL-S-8805/26 VERSIONS ORDER GUIDE
Toggle Lever Position Standard Lever
‘‘T2’’ Terminals Tab Lever
‘‘T2’’ Terminals
Keyway Opposite
Keyway
No. of
Poles/
Switches Type
Contacts Catalog Listing Military No. Catalog Listing Military No.
Maint. Maint. 2 Silver 23AT73-T2 M8805/26-001 23AT473-T2 M8805/26-003
4 Silver 23AT74-T2 M8805/26-002 23AT474-T2 M8805/26-004
Manuals
Manual Switches 13T Series
Toggle Switch Assemblies
66 HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
AT 3-POSITION ORDER GUIDE
Pull-To-Unlock Lever
Toggle Lever Position Standard Lever Tab Lever Solder Terminals
Opposite No. of
Poles/ Type Solder ‘‘T’’ ‘‘T2’’ ‘‘T2’’ (Add locking letter
Keyway Center Keyway Switches Contacts Terminals Terminals Terminals Terminals to cat. listings below)
Maint. Maint. Maint. 2 Silver 13AT2 13AT2-T 13AT2-T2 13AT402-T2 13AT2- Locking letters:
All types
Gold 13AT18 13AT18-T
3 Silver 13AT5 13AT5-
4 Silver 13AT9 13AT9-T2 13AT409-T2 13AT9-
Gold 13AT29
Mom. Maint. Mom. 2 Silver 13AT1 13AT1-T 13AT1-T2 13AT401-T2 13AT1- Locking letters:
E, L, or N
Gold 13AT26 13AT423-T2
3 Silver 13AT4 13AT413-T2
4 Silver 13AT8 13AT8-T2 13AT8-
Gold
Maint. Maint. Mom. 2 Silver 13AT3 13AT3-T 13AT3-T2 13AT403-T2 13AT3- Locking letters:
E, G, B, L, P or N
Gold
4 Silver 13AT10 13AT410-T2 13AT10-
AT MIL-S-8805/26 VERSIONS ORDER GUIDE
Toggle Lever Position Standard Lever Tab Lever
‘‘T2’’ Terminals ‘‘T2’’ Terminals
Opposite No. of
Poles/ Type
Keyway Center Keyway Switches Contacts Catalog Listing Military No. Catalog Listing Military No.
Mom. Maint. Mom. 2 Silver 13AT271-T2 M8805/26-005 13AT471-T2 M8805/26-006
3 Silver 13AT474-T2 M8805/26-012
Maint. Maint. Maint. 2 Silver 13AT272-T2 M8805/26-007 13AT472-T2 M8805/26-008
3 Silver 13AT275-T2 M8805/26-013
Maint. Maint. Mom. 2 Silver 13AT273-T2 M8805/26-009 13AT473-T2 M8805/26-010
LEVER-TO-BUSHING SEAL OPTION
A splash type lever-to-bushing seal can
be provided to help prevent the entrance
ofmoistureanddustbehindthepanel,or
into the contact area.
HERMETICALLY SEALED BASIC
SWITCH OPTION
AT’s with 1532 Nbushings can be furnished
with HM or HS hermetically sealed basic
switches, which have metal-to-metal fu-
sionaround the cover, actuator base and
mounting holes. Terminals are sealed
glass-to-metal. For more information,
contact your MICRO SWITCH Sales Of-
fice. Shown with
HM basic switches
LOCKING CONFIGURATIONS
When ordering pull-to-unlock toggle list-
ings, add the suffix letter shown in this
chart to the standard toggle catalog list-
ing and the Military Approval number.
ABDEFGH
Locked In Locked Out Of
Center and Locked Out Locked In Locked In Center And
Locked In Extreme Position Of Center Locked In Extreme Position Extreme Position Extreme Position
Three Positions (Keyway Side) Position Center Position (Opposite Keyway) (Keyway Side) (Keyway Side)
JKLMNP
Locked Out Of Locked In Locked Out Of Locked Out Of
Center And Center And Locked Out Of And Into Locked Out Of And Into
Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position Extreme Position
(Opposite Keyway) (Opposite Keyway) (Keyway Side) (Opposite Keyway) (Opposite Keyway) (Keyway Side)
Manual Switches 60AT Series
Toggle Switch Assemblies
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada67
Standard lever Pull-to-unlock lever
ELECTRICAL RATINGS Basic Switches (in amperes)
Sea Level 50,000 Ft.
115 VAC* 250 VAC 115 VAC* 250 VAC
Load 28 VDC 400 Hz 60 Hz 28 VDC 400 Hz 60 Hz
Resistive 7 7 7 7 7 7
Inductive 4** 7 7 2.5** 7 7
Motor 4 3.3 3.3 4 3.3 3.3
Lamp 2.5 2 2 2.5 2 2
Inrush: 20 amps * 75% power factor. ** Use AN31796 inductor.
FEATURES
1
Compact multi-pole design conserves
space and weight
1
2, 4, 6, or 8 SPDT precision basic
switches
1
2 or 3-position, momentary and main-
tained action
1
15/32Nbushing
1
Standard or pull-to-unlock toggle
levers
1
MIL-S-8805/98 qualified versions
PULL-TO-UNLOCK OPTION
As a guard against accidental operation,
pull-to-unlock levers must be pulled .090
in./2,3mm(approx.)tochangepositions.
See chart on facing page which shows
locking configurations and locking letter
suffix codes which are referred to in the
order guides.
Note: To order replacements for the resil-
ient white caps which are screwed onto
60AT locking levers, specify Catalog List-
ing15PA90-6W.
AT 2-POSITION ORDER GUIDE CJcommon, NC Jnormally closed, NO Jnormally open.
Numbers Jbasic switch designations.
Standard Lever
Circuits Made With Toggle At: Catalog Listing Pull-To-Unlock
Lever Suffix
Keyway Position Opposite Keyway With MIL-S-6743 With MIL-S-8805/4 (Add locking letter
No. of
Poles/
Switches C-NC C-NO C-NC C-NO Basic Switches Basic Switches to cat. listings)
2 1, 2 1, 2 62AT11-3 62AT22-3 D, G
1, 2* 1, 2 62AT11-8 62AT22-8 F
1, 2 1, 2* 62AT11-82 62AT22-82 G
4 1, 2 3, 4 3, 4 1, 2 64AT11-3 64AT22-3 D, F, G
6 1, 2, 3 4, 5, 6 4, 5, 6 1, 2, 3 66AT11-3 66AT22-3 D, F, G
8 1, 2, 3, 4 5, 6, 7, 8 5, 6, 7, 8 1, 2, 3, 4 68AT11-3 68AT22-3 D, F, G
AT MIL-S-8805/98 VERSIONS (WITH BUSHING AND PANEL SEALS) ORDER GUIDE
Circuits Made With Toggle At: Standard Lever Version
Keyway Position Opposite Keyway
No. of
Poles/
Switches C-NC C-NO C-NC C-NO Catalog Listing Military No.
4 1, 2 3, 4 3, 4 1, 2 64AT300-3 M8805/98-015
6 1, 2, 3 4, 5, 6 4, 5, 6 1, 2, 3 66AT300-3 M8805/98-046
8 1, 2, 3, 4 5, 6, 7, 8 5, 6, 7, 8 1, 2, 3, 4 68AT300-3 M8805/98/077
* Momentary positions. All others are maintained.
Manuals
Manual Switches 60AT Series
Toggle Switch Assemblies
68 HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
60AT SERIES 3-POSITION ORDER GUIDE C Jcommon, NC Jnormally closed, NO Jnormally open.
Numbers Jbasic switch designations.
Standard Lever
Catalog Listing
With
MIL-S-6743
Basic Switches
With
MIL-S-8805/4
Basic Switches
Pull-To-Unlock
Lever Suffix
(Add locking letter
to cat. listings)
Circuits Made With Toggle At:
Keyway Position Center Position Opposite Keyway
No. of
Poles/
Switches C-NC C-NO C-NC C-NO C-NC C-NO
2 1 2 1, 2 2 1 62AT11-1 62AT22-1 All Types
4 1, 2 3, 4 All 3, 4 1, 2 64AT11-1 64AT22-1 All Types
1, 2 3, 4 All 3, 4* 1, 2* 64AT11-514 64AT22-514 B, E, G, L, N, P
1, 2* 3, 4* All 3, 4 1, 2 64AT11-5 64AT22-5 E, F, K, L, M, N
1, 2* 3, 4* All 3, 4* 1, 2* 64AT11-7 64AT22-7 E, L, N
6 1, 2, 3 4, 5, 6 All 4, 5, 6 1, 2, 3 66AT11-1 66AT22-1 All Types
1, 2, 3* 4, 5, 6* All 4, 5, 6 1, 2, 3 66AT11-5 66AT22-5 E, F, K, L, M, N
1, 2, 3* 4, 5, 6* All 4, 5, 6* 1, 2, 3* 66AT11-7 66AT22-7 E, L, N
1, 2, 3 4, 5, 6 All 4, 5, 6* 1, 2, 3* 66AT22-514 66AT22-514 B, E, G, L, N, P
8 1, 2, 3, 4 5, 6, 7, 8 All 5, 6, 7, 8 1, 2, 3, 4 68AT11-1 68AT22-1 All Types
1, 2, 3, 4* 5, 6, 7, 8* All 5, 6, 7, 8 1, 2, 3, 4 68AT11-5 68AT22-5 E, F, K, L, M, N
1, 2, 3, 4* 5, 6, 7, 8* All 5, 6, 7, 8* 1, 2, 3, 4* 68AT11-7 68AT22-7 E, L, N
1, 2, 3, 4 5, 6, 7, 8 All 5, 6, 7, 8* 1, 2, 3, 4* 68AT11-514 68AT22-514 B, E, G, L, N, P
60AT MIL-S-8805/98 Versions (With bushing and panel seals)
Standard Lever Version
Circuits Made With Toggle At: (Pull-to-unlocks
Keyway Position Center Position Opposite Keyway listed below order guide)
No. of
Poles/
Switches C-NC C-NO C-NC C-NO C-NC C-NO Catalog Listing Military No.
4 1, 2 3, 4 All 3, 4 1, 2 64AT300-1 M8805/98-001
1, 2* 3, 4* All 3, 4 1, 2 64AT300-5 M8805/98-019
1, 2* 3, 4* All 3, 4* 1, 2* 64AT300-7 M8805/98-026
6 1, 2, 3 4, 5, 6 All 4, 5, 6 1, 2, 3 66AT300-1 M8805/98-032
1, 2, 3* 4, 5, 6* All 4, 5, 6 1, 2, 3 66AT300-5 M8805/98-050
1, 2, 3* 4, 5, 6* All 4, 5, 6* 1, 2, 3* 66AT300-7 M8805/98-057
8 1, 2, 3, 4 5, 6, 7, 8 All 5, 6, 7, 8 1, 2, 3, 4 68AT300-1 M8805/98-063
1, 2, 3, 4* 5, 6, 7, 8* All 5, 6, 7, 8 1, 2, 3, 4 68AT300-5 M8805/98-081
1, 2, 3, 4* 5, 6, 7, 8* All 5, 6, 7, 8* 1, 2, 3, 4* 68AT300-7 M8805/98-092
*Momentary postions. All others are maintained.
60AT MIL-S-8805/98 Pull-to-Unlock Versions (With bushing and panel seals)
These switches have the same circuitry
as their companion standard lever cata-
log listings in the MIL-S-8805/98 order
guides. Example: 64AT300-1 has the
same circuitry as 64AT300-1A. (Refer to
locking chart on page 53.) Note: It is not
necessarytoadd lockinglettersuffixesto
M8805/98 military numbers.
Cat. Listing Military No. Cat. Listing Military No. Cat. Listing Military No. Cat. Listing Military No.
64AT300-1A M8805/98-002 64AT300-5M M8805/98-024 66AT300-3F M8805/98-048 68AT300-1K M8805/98-072
-1B -003 -5N -025 -3G -049 -1L -073
-1D -004 64AT300-7E M8805/98-027 66AT300-5E -051 -1M -074
-1E -005 -7L -028 -5F -052 -AN -075
-1F -006 -7N -029 -5K -053 -1P -076
-1G -007 -5L -054 68AT300-3D M8805/98-078
-1H -008 66AT300-1A M8805/98-033 -5M -055 -3F -079
-1J -009 -1B -034 -5N -056 -3G -080
-1K -010 -1D -035 66AT300-7E M8805/98-058 68AT300-5E -082
-1L -011 -1E -036 -7L -059 -5F -083
-1M -012 -1F -037 -7N -060 -5K -084
-1N -013 -1G -038 -5L -085
-1P -014 -1H -039 68AT300-1A M8805/98-064 -5M -086
64AT300-3D M8805/98-016 -1J -040 -1B -065 -5N -087
-3F -017 -1K -041 -1D -066 68AT300-7E -089
-3G -018 -1L -042 -1E -067 -7L -090
64AT300-5E M8805/98-020 -1M -043 -1F -068 -7N -091
-5F -021 -1N -044 -1G -069
-5K -022 -1P -045 -1H -070
-5L -023 66AT300-3D M8805/98-047 -1J -071
Manual Switches AT Series
Toggle Switch Assemblies
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada69
MOUNTING DIMENSIONS (For reference only)
13/23AT
PANEL CUTOUTS
14NBushing
1532NBushing
NOTE—
64AT300, 66AT300, and 68AT300 (M8805/98) listings have
a bushing seal and MS25196 panel seal.
62AT
64/66/68AT
A’ DIMENSION
4-POLE17,0/.67
6-POLE 23,6/.93
8-POLE 29,7/1.17
Manuals
Manual Switches ET Series
Magnetically Held Toggle Switches
70HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
PRINCIPLE OF OPERATION
A holding coil in ET toggle switches re-
places mechanical holding mechanisms
to maintain the toggle in an operate posi-
tion. The toggle is released by breaking
the coil circuit.
When the hold in coil circuit is open, the
ET functions as a momentary contact
switch. When the coil is energized
(throughremotecontacts),thetogglelev-
erwillbe held (maintained)inthe operate
position. De-energizing the coil causes
the lever to snap back to the unoperated
position. The lever can also be released
manually (overridden).
Note:Thesolenoid has a holdincapacity
only.Itwillnotpull the toggleleverinto an
operating position from an unoperated
position.
Two position. The illustration above
shows the operating sequence for an ET
with one SPDT circuit. (1) circuit closed
manually; (2) energized solenoid holds
switchcircuit closed;and(3) remotecon-
trol breaks solenoid circuit, releases the
toggle, and opens the switch circuit. (In
ETs with two SPDT circuits, both circuits
transfer when the lever is operated.)
ELECTRICAL RATINGS
Amperage
Sea Level (Sealed) 65,000 ft
Rating
Code Voltage Res. Ind. Motor Res. Ind. Motor
A28DC42.54424
B28DC43442.54
C 28 DC 7 2 5 1.5
FEATURES
1
Most listings qualified to MIL-S-5594
1
Environment-proof sealing
1
2 and 3 position magnetically main-
tained toggle action
1
Standard, tab, and pull-to-unlock
levers
1
Turret, leadwire, and screw terminals
1
Temperature range: –85Fto+160F
(–65Cto+71C)
Three position. ETs with two SPDT cir-
cuitshaveamagneticholdincapabilityin
bothdirectionsfromcenter.Whenthelev-
er is in the center position, the circuitry is
as shown in the illustration above. When
the lever is moved to one extreme posi-
tion, switch (A) circuit is transferred and
switch(B)circuitisunchanged.Intheoth-
er extreme position, switch (B) circuit is
tranferred while switch (A) circuit is un-
changed.
Manual Switches ET Series
Magnetically Held Toggle Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada71
Toggles
Standard Pull-to-unlock Push-to-unlock Tab
Terminals
Turret Leadwire Screw
TOGGLE TYPES
Standard Tapered matte finish stain-
less steel.
Pull-to-unlock Prevents accidental ac-
tuation;mustbepulled out to changepo-
sitions.
Push-to-unlock Guards against acci-
dental operation. The toggle must be de-
pressedapproximately.100 inch before it
can be moved to either extreme position.
Energizing the coil causes the extreme
positionstobeelectricallymaintainedun-
til the coil circuit is broken.
Tab Paddle-shaped clear anodized
aluminum tab.
TERMINAL TYPES
Turret Plated for easy solder connec-
tion of up to #14 wire.
Leadwire No. 20 wire per MIL-W-5086,
markedperMIL-W-5088.Standard length
of six feet. Leadwire ends are stripped.
Other material and lengths can be fur-
nished. Contact your nearest MICRO
SWITCH Sales Office for further informa-
tion.
Screw–Four 48UNF x .188 (ref.) long
round head screws with lockwashers.
Separated by molded phenolic barriers.
CIRCUIT OPERATION
Turret Terminals Leaded Terminals
Two-Position Toggle Three-Position Toggle Three-Position Toggle
Circuit Made With Toggle At: Circuit Made With Toggle At: Circuit Made With Toggle At:
Keyway* Opposite Keyway* Center Opposite Keyway* Center Opposite
Circuitry Position Keyway Position Position Keyway* Position Position Keyway*
SPDT 1-3 1-2
DPDT 1-3, 4-6 1-2, 4-5 1-3, 4-5 1-2, 4-5 1-2, 4-6 1-2, 4-5 1-3, 4-5 1-3, 4-6
* These positions are magnetically held when coil is energized, and momentary when coil is not energized.
CIRCUIT OPERATION
Screw Terminals
Three-Position Toggle
Circuit Made With Toggle At:
Keyway* Center Opposite
Position Position Keyway*
1-2 MADE 1-2 OPEN 1-2 OPEN
3-4 OPEN 3-4 OPEN 3-4 MADE
* These positions are magnetically held when coil is
energized, and momentary when coil is not
energized.
CIRCUITRY Single-pole Double-pole
Double-throw Double-throw
Manuals
Manual Switches ET Series
Magnetically Held Toggle Switches
72HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
ET ORDER GUIDE
Max. Weight Max.
Dimension A
Circuitry
No. of
Toggle
Positions Lever Type Terminals
Elec.
Rating
Code
Page 72 grams ounces mm inches Catalog Listing
2 Standard Leadwire B 241 8.5 51,6 2.03 25ET61-6 (M5594/1-1)
(90Nfrom
Keyway)
2 Standard Solder Turret B 113 4.0 47,5 1.87 25ET61-T (M5594/1-2)
2 Standard Screw B 113 4.0 61,2 2.41 25ET61-S (M5594/1-3)
2 Tab Lever Leadwire in B 241 8.5 51,6 2.03 25ET62-6 (M5594/1-4)
line with
Keyway
SPDT 2 Standard Leadwire B 241 8.5 51,6 2.03 25ET63-6 (M5594/1-5)
(180Nfrom
Keyway)
2 Standard Leadwire B 241 8.5 51,6 2.03 25ET64-6 (M5594/1-6)
(90Nfrom
Keyway)
2 Standard Solder Turret A 113 4.0 47,5 1.87 26ET61-T (M5594/2-1)
2 Standard Solder Turret A 113 4.0 47,5 1.87 26ET65-T (M5594/2-2)
DPDT 3 Standard Solder Turret C 113 4.0 58,7 2.28 27ET61-T (M5594/3-1)
3 Pull-to-unlock Solder Turret C 113 4.0 58,7 2.28 27ET61-T-E (M5594/6-1E)
3 Push-to-unlock Solder Turret C 113 4.0 58,7 2.28 27ET51-T
3 Pull-to-unlock Solder Turret C 113 4.0 58,7 2.28 27ET61-T-M (M5594/6-1M)
MOUNTING DIMENSIONS (For reference only)
Standard and tab toggle levers
Pull-to-unlock toggle lever
Push-to-unlock toggle lever
LOCKING CONFIGURATION
EM
Locked In
Center Position
Locked Out Of
And Into Extreme
Position (Opposite
Keyway)
Manual Switches
Toggle Accessories
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada73
TOGGLE LEVER SLEEVES
Colored plastic lever sleeves are ordered
by adding suffix letters which denote the
desired color to the basic catalog listing.
ORDER GUIDE
Color Suffix
Basic
Toggle Switch Type Catalog Listing Blue Black White Green Yellow Red
AT with Short lever 15PA90-1 BL BK W G Y R
14Nbushing Long lever 15PA90-3 W R
AT, TL, TK, TS, TW, ET with 1532N15PA90-4 BK W R
bushing and standard lever BL G Y
Example:15PA90-1R
Red sleeve fits 14in. bushing AT’s with
short levers.
DECORATIVE MOUNTING NUT ORDER GUIDE
Style Description Bushing Size Catalog Listing
A
Knurled Nut 14N19PA5-1
(Bright Nickel) 1532N19PA6-1
(Black Finish) 1532N19PA6-4
B
Knurled Capnut 1532N19PA6-2
(Bright Nickel)
C
Hex Nut 14N19PA5-3
(Black Finish)
1532N19PA6-3
D
Tapered Nut 1532N19PA6-5
(Chrome Finish)
E
Hex Nut 14N19PA104-TW
(Chrome Finish)
PANEL SEAL
Forusewith1532 in.bushingtoggleswitch-
es,thiscorrosionresistantsteelcupwash-
erhasasiliconeelastomerliningandkey-
ing tab for sealing the bushing keying
slot. Use in panels up to .125 in./31,8 mm
thick.
Catalog
Listing Military No.
15PA87
15PA195-TL M5423/16-01
15PA258 M5423/16-01
LEVER/PANEL SEAL
Forusewithstandardlevertoggleswitch-
es with1532 in. bushings. Consists of a sil-
icone elastomer seal boot and panel seal
bonded to a hex nut.
Catalog Listing 10PA4
Manuals
Manual Switches EPM Series
Sealed Pushbutton Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada75
FEATURES
1
High-intensity LEDs indicate status
changesbrilliant colordisplaycan be
distinguishedevenunderhighambient
lighting conditions
1
Soft-glow LED backlighted legends for
low ambient viewing
1
Rugged sealed construction with-
stands effects of shock and vibration
provides dependable switching/light-
ed display in severe environment
applications
1
Designed to comply with MIL-S-22885
1
Suitable for use in NEMA 4 and 13
enclosures
1
Low travel (.030 in. max.), with tactile
feedback for definite feel of switching
action
1
Front-of-panel, hard mounting
1
Compact size
1
Field-replaceable legends
1
ULrecognized, CSA certified, and MIL-
S-8805 qualified basic switches
1
EPM22 electronic control and EPM32
power duty switching for electrical
flexibility
1
MatchingEPM41indicatorsforuniform
panel appearance
1
Choice of two housing styles:
Type C: Standard sealed EPM hous-
ings
Type B: Enhanced sealed EPM hous-
ingswithIRfiltersforvehiclelightingse-
curity, designed to MIL-STD-461 (EMI
shielding), NBC compliance per
AR70-71
EPM Series Sealed Pushbutton Switches
meet high-performance needs for rug-
ged, compact size sealed switches that
are exposed to water, oil, cleaning sol-
vents, and many industrial chemicals.
They provide long, reliable operating life
under conditions of high shock and
vibration in severe environment applica-
tions.
Inadditiontobeingbuilttostanduptode-
manding environments, EPM switches
adheretogoodhumanfactorsprinciples.
Thedesigncombines lowtravelwithhigh
tactile feedback and meets arctic glove
requirements. Raised barriers on the be-
zel enhance finger positioning and help
prevent inadvertent operation of two
abutting units at one push. Lighted dis-
play options provide further application
versatility.
LED ILLUMINATION
Long-life LEDs enable reliable illumina-
tion. They resist effects of shock and vi-
bration, reducing service and mainte-
nance requirements. (Unlighted versions
are also available.)
The following lighting functions can be
furnished: High-intensity display using
two LEDs to create a brilliant light signal
that can be distinguished under high am-
bient conditions, and/or a pair of LEDs
whichsoftlybacklightthelegendforview-
ing under low ambient conditions.
There is a choice of red, green or yellow
LEDs.Matchingindicators,whichprovide
lighted display only, complement the
switches to help present a uniform panel
design.
ELECTRICAL FLEXIBILITY
EPM switches can be furnished with one
or two SPDT basics. EPM22 electronic
control switches handle up to 1 amp,
EPM32 power duty switches up to 7
amps.
EASY TO INSTALL
Front panel hard-mounting is quick and
easy. Only a screwdriver is needed to
tighten the swing-out mounting lugs,
which securely lock and seal the unit in
thepanel.Though the cover/bracketsim-
ply snaps onto the housing, it has inher-
ent tamper resistance. The cover can be
removed intentionally with a small screw-
driver(orothertool)toaddorchangeleg-
ends.
EPM’s 34-inch square panel cutout on 1-
inch centers is suited to row, column, or
matrix arrays.
CONSTRUCTION
Insert can be furnished with or without
legends.Iflegendsaretobebacklight-
ed, darker colors are recommended
fortheinsert.Blackprovidesmaximum
contrast in lighted legend displays.
Diffuserplatesspecifiedforlightedleg-
end devices are coated on the under-
side for even illumination. When un-
lighted legends are specified, diffuser
platesaremoldedfromopaque plastic
andarenotinterchangeablewiththose
used for lighted legends.
Manuals
Manual Switches EPM Series
Sealed Pushbutton Switches
76 HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
SPECIFICATIONS
Environmental Operating Temperature 40 to 85C(40 to 185F)
Storage Temperature 54 to 85C(65 to 185C)
Seals Viton bezel-to-panel gasket seal
and neoprene cover seal
Protection NEMA 4 and 13
Mechanical Total Travel .030 in. (0,76 mm) max.
Operating Force 20 to 60 oz. (5,56 to 16,7 N) typical
Electrical Contact arrangement 1 or 2 SPDT
Electrical rating EPM22/24 switches 28 VDC: .5 amp ind., 1 amp res.
(sea level or 50,000 ft.), 2 amps max. inrush.
1 amp, 125 VAC (UL code L22).
EPM32/34 switches 28 VDC: 4 amps ind., 7 amps res.
(sea level), 2.5 amps ind., 4 amps res. (50,000 ft).
115 VAC, 60 Hz: 7 amps res. or ind. (sea level).
EPM22/32 SWITCHES WITH SINGLE INDICATOR ORDER GUIDE
EPM22B Y R 6 AC L
Housing Type and
Switch Contacts Legend
Color1
Hi-Intensity
Indicator
Color
Switch
and LED
Terminals Circuitry
Code Insert Type
Standard Type C
Sealed Housing:
EPM22C
(Gold Contacts)
EPM32C
Silver Contacts
Enhanced Type B
Sealed Housing, with
IR filters, EMI shielding
& NBC compliance:
EPM22B
(Gold Contacts)
EPM32B
(Silver Contacts
RRed
YYellow
GGreen
XNo LED
RRed
YYellow
GGreen
XNo LED
2
Printed Circuit
6
Hook style
LED terminals
and solder T2
switch
terminals
AC
1-Pole
BC
2-Pole
(All are
momentary
action)
LLegended insert.
Use Legend Order Sheet
FO-43973 to designate insert
color and legend.
XNo insert furnished.2
Unlegended insert:1
BBlue
RRed
YYellow
GGreen
WWhite
KBlack
1. When specifying Legend Color (R, Y, G),
the insert Type suffix letter must be either:
L(legended insert), or X(no insert
furnished).
2. To order insert separately, see EPM95
order guide.
Example: EPM22BYR6ACL
Enhanced Type Bsealed housing, gold contacts; high-intensity single indicator red lighted
display and yellow legend backlighting, hook style LED terminals and solder T2 switch
terminals; 1-pole circuitry, momentary action, furnished with legended insert, as specified in
FO-43973.
Manual Switches EPM Series
Sealed Pushbutton Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada77
EPM24B Y D 6 AC L
Housing Type
and Switch
Contacts Legend
Color1
Hi-Intensity Indicator Colors
Color
Code Upper
LED Lower
LED
Switch
and LED
Terminals Circuitry
Code Insert Type
Standard Type C
Sealed Housing:
EPM24C
(Gold Contacts)
EPM34C
(Silver Contacts)
Enhanced Type B
Sealed Housing,
incl. IR filters, EMI
shielding & NBC
compliance:
EPM24B
(Gold Contacts
EPM34B
(Silver Contacts)
RRed
YYellow
GGreen
XNo LED
R
Y
G
F
A
B
C
D
E
Red
Yellow
Green
Red
Yellow
Yellow
Green
Green
Red
Red
Yellow
Green
Green
Green
Red
Yellow
Red
Yellow
2
Printed
Circuit
6
Hook style
LED
terminals
and solder
T2 switch
terminals
AC
1-Pole
BC
2-Pole (All
are
momentary
action)
LLegended insert.
Use Legend Order Sheet
FO-43973 to designate insert
color and legend.
XNo insert furnished.2
Unlegended Insert:1
BBlue
RRed
GGreen
WWhite
KBlack
1. When specifying Legend Color (R, Y, G),
the insert Type suffix letter must be either:
L(legended insert), or X(no insert
furnished).
2. To order insert separately, see EPM97
order guide.
Example: EPM24BYD6ACL
Enhanced Type Bsealed housing, gold contacts; yellow legend backlighting; high-intensity
dual indicator green/red lighted display; hook style LED terminals and solder T2 switch
terminals;1-pole momentary action, furnished with legended insert, as specified in FO-43973.
EPM41B Y R 2 L
Housing Type and
Switch Contacts Legend Color1Hi-Intensity
Indicator Color LED Terminals Insert Type
Standard Type C
Sealed Housing:
EPM41C
Enhanced Type B
Sealed Housing with
IR filters, EMI
shielding & NBC
compliance:
EPM41B
RRed
YYellow
GGreen
XNo LED
RRed
YYellow
GGreen
XNo LED
2
Printed Circuit
6
Hook style
LLegended insert.
Use Legend Order Sheet FO-43973 to
designate insert color and legend.
XNo insert furnished.2
Unlegended Insert:1
BBlue
RRed
YYellow
GGreen
WWhite
BBlack
1. When specifying Legend Color (R, Y, G),
the insert Type suffix letter must be either:
L(legended insert), or X(no insert
furnished).
2. To order insert separately, see EPM95
order guide.
Example: EPM41BYR2L
Enhanced Type Bsealed housing; high-intensity single indicator red lighted display and yellow
legend backlighting, printed circuit LED and switch terminals; furnished with legended insert,
as specified in FO-43973.
Manuals
Manual Switches EPM Series
Sealed Pushbutton Switches
78HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
EPM44 DUAL INDICATORS (NO SWITCHES) ORDER GUIDE
EPM44B Y D 2 L
Housing Type and
Switch Contacts Legend
Color1
Hi-Intensity Dual Indicator Colors
Color
Code Upper
LED Lower
LED LED
Terminals Legend Insert Type
Standard Type C
Sealed Housing:
EPM44C
Enhanced Type B
Sealed Housing, incl.
IR filters, EMI
shielding & NBC
compliance:
EPM44B
RRed
YYellow
GGreen
XNo LED
R
Y
G
F
A
B
C
D
E
Red
Yellow
Green
Red
Yellow
Yellow
Green
Green
Red
Red
Yellow
Green
Green
Green
Red
Yellow
Red
Yellow
2
Printed
Circuit
6
Hook style
LLegended insert.
Use Legend Order Sheet
FO-43973 to designate
insert color and legend.
XNo insert furnished.2
Unlegended Insert:1
BBlue
RRed
GGreen
WWhite
KBlack
1. When specifying Legend Color (R, Y, G),
the insert Type suffix letter must be either:
L(legended insert), or X(no insert
furnished).
2. To order insert separately, see EPM97
order guide.
Example: EPM44BYD2L
Enhanced Type Bsealed housing; yellow legend backlighting; high-intensity dual indicator
green/red display; printed circuit LED and switch terminals; furnished with legended insert, as
specified in FO-43973.
HOW TO ORDER INSERTS SEPARATELY
Legended inserts: To order inserts legended by MICRO SWITCH as separate
items, order Catalog Listing EPM94, and use Legend Order Sheet to specify the
insert color and desired legend. Unlegended inserts: Use order guide below to
order inserts without legends.
EPM95 UNLEGENDED INSERTS ORDER GUIDE
Unlegended inserts can be furnished with or without a display window for hi-
intensity LED lighting.
Inserts for Type BHousings: Inserts For Type CHousings:
Color With window Without window With window Without window
Blue EPM95BBW EPM95BBN EPM95CBW EPM95CBN
Green EPM95BGW EPM95BGN EPM95CGW EPM95CGN
Red EPM95BRW EPM95BRN EPM95CRW EPM95CRN
White EPM95BWW EPM95BWN EPM95CWW EPM95CWN
Yellow EPM95BYW EPM95BYN EPM95CYW EPM95CYN
Black EPM95BKW EPM95BKN EPM95CKW EPM95CKN
Gray EPM95BPW EPM95BPN EPM95CPW EPM95CPN
EPM97 INSERTS FOR DUAL INDICATOR DEVICES
Inserts for Type BHousings: Inserts For Type CHousings:
Color With window Without window With window Without window
Blue EPM97BBW EPM97BBN EPM97CBW EPM97CBN
Green EPM97BGW EPM97BGN EPM97CGW EPM97CGN
Red EPM97BRW EPM97BRN EPM97CRW EPM97CRN
White EPM97BWW EPM97BWN EPM97CWW EPM97CWN
Yellow EPM97BYW EPM97BYN EPM97CYW EPM97CYN
Black EPM97BKW EPM97BKN EPM97CKW EPM97CKN
Gray EPM97BPW EPM97BPN EPM97CPW EPM97CPN
Manual Switches EPM Series
Sealed Pushbutton Switches
HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada79
Manuals
Manual Switches EPM Series
Sealed Pushbutton Switches
80HoneywellSensingandControl11-800-537-6945USA1F1-815-235-6847International11-416-293-8111Canada
MOUNTING DIMENSIONS (For reference only)
0,0–mm
0.00 in.
LED Application Data
External resistors should be added to maintain the LED current
at30mAmax.,20mAtypical.Aminimumof10VDCopencircuit
voltage with an appropriate series resistance be used to drive
the LEDs. This minimized the effect of temperature (current var-
iation) on forward voltage of the LEDs. The example below il-
lustratesasimpleDCcircuitandtheequationusedtodetermine
the value of the series resistance.
RS=EVF
IF
Where: RS=Series Resistance
E=Supply
VF=Forward Voltage of LED
IF=Circuit Current
Example: RS=10 4.4 =280 ohms
.020
For: E =10 volts
VF=4.4 volts
IF=.020 amp
Characteristics: LED forward voltage @ .020
mA, VF: Red, 4.4; yellow, 4.4; green, 4.6.
Panel Cutout
Panel thickness: .063 to .189 in.
(1,6 to 4,8 mm)
Center-to-center: 1in. (25,4 mm)
rows or columns
Circuit Diagram
Switch Circuitry LED Circuitry
Terminal Detail
Notes:
1. LED terminals are Type2–PConly.
2. Mounting torque: 2 to 212in.–lbs.
Manual Switches NR Series
Sealed Rocker Switches
54 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
GENERAL INFORMATION
MICRO SWITCH NR Series Rocker Switches meet severe environment application
needs for a rugged, cost-effective manual switch. They combine the advantages of
toggle switch circuit versatility with pushbutton control.
Quality construction features include a premolded elastomer seal between the actua-
torandbushingandanelastomercover/casegasketseal.Also,theterminalinsertsare
molded into the high impact strength thermoplastic case.
Complete sealing of the switching chamber enables compliance with UL 508, para-
graph13.3hosedowntest.Theseswitchescanbeusedwherepanelsaresubjectedto
periodic splash and washdowns, such as are common to food and beverage equip-
ment. They will also withstand exposure to heavy accumulations of eary morning dew
that may condense on the control panel in cabs of vehicles left outdoors overnight.
Above Panel Mount Flush Panel Mount
12PA ROCKER ORDER GUIDE
Note: These listings are used to specify
rockers only.
Rocker Catalog
Color Listing
White 12PA12-W
Red 12PA12-R
Yellow 12PA12-Y
Black 12PA12-BK
Green 12PA12-G
Blue 12PA12-BL
FEATURES
1
Completely sealed switching chamber
1
Colored removable rockers
1
Flush-panel or above-panel mounting
1
Step-design case provides added
space between terminals to help pre-
vent shorting
1
1, 2 or 4-pole circuitry
1
2 or 3 positions, maint./mom. action
1
Spring-loaded actuating mechanism
provides excellent tactile feedback
1
High impact strength, non-tracking
case enhances electrical stability
1
Temperature range: 40 to 71°C(40
to160°F)
1
UL Recognized
ELECTRICAL RATINGS
L191: 15 amps,125, 250, 277 VAC;12Hp,
125 VAC;1Hp, 250, 277 VAC;
5 amps,125 VAC ‘‘L’’
L192: 10amps,125, 250, 277VAC;14Hp,
125 VAC; 12Hp, 250, 277 VAC;
3 amps,125 VAC ‘‘L’’
HOW TO ORDER
1. To orderflush panel mount switches
withoutrockers,
specifythelistingsin
the NR order guides.
2. To specify above-panel mount
switches,
without rockers,
change
the 1(after ‘‘NR’’) in 1NR1, 11NR1,
2NR1, 12NR1, 4NR1, and 14NR1list-
ingsintheNRorderguidesto4.Exam-
ple: 1NR1-2W converts to 1NR4-2W,
11NR1-2W to 11NR4-2W.
For 1NR91, 2NR91, and 14NR91 list-
ings add 4(after the ‘‘NR’’) to specify
theabovepanelmountversion.Exam-
ple:1NR91-2W becomes1NR491-2W.
3. To order rockers separately, specify
listings in the12PA order guide.
4. To specify rockers furnished with
switches, add the appropriate suffix
letter to the switch listings, e.g.,
W=White, R=Red, Y=Yellow,
BK=Black, G=Green, BL=Blue. Ex-
ample: 1NR1-2 with a white rocker is
1NR1-2W.
Application Note: Honeywell MICRO
SWITCH does
not
recommend the use of
silver cadmium oxide switch contacts in
non-arcing loads. Non-arcing loads are
generally loads less than 12 volts and/or
0.5amp.NRswitchesusesilvercadmium
oxide contacts. If you have questions,
contact the MICRO SWITCH Application
Center at1-800-537-6945.
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Manual Switches NR Series
Sealed Rocker Switches
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 55
NOTE: Catalog listings in the order
guides below do not include
rocker operators. See ‘‘How to
Order.’’
NR 2-POSITION FLUSH-PANEL MOUNT ROCKERS ORDER GUIDE
Circuits Made With Rocker At:
Termination Style
No.
of
Poles Ident. Lug
Position Opposite Lug
Position UL Rating
Code Screw Solder Q-C
OFF 2-3 L191 1NR1-2 11NR1-2 1NR91-2
1 1-2 2-3 L191 1NR1-3 11NR1-3 1NR91-3
OFF* 2-3 L192 1NR1-4 11NR1-4 1NR91-4
1-2* OFF L192 1NR1-6 11NR1-6 1NR91-6
1-2* 2-3 L192 1NR1-8 11NR1-8 1NR91-8
OFF 2-3, 5-6 L191 2NR1-2 12NR1-2 2NR91-2
2 1-2, 4-5 2-3, 5-6 L191 2NR1-3 12NR1-3 2NR91-3
OFF* 2-3, 4-6 L192 2NR1-4 12NR1-4 2NR91-4
1-2, 4-5* OFF L192 2NR1-6 12NR1-6 2NR91-6
1-2, 4-5* 2-3, 4-6 L192 2NR1-8 12NR1-8 2NR91-8
OFF 2-3, 5-6, 8-9, 11-12 L191 4NR1-2 14NR1-2 4NR91-2
4 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 L191 4NR1-3 14NR1-3 4NR91-3
OFF* 2-3, 5-6, 8-9, 11-12 L192 4NR1-4 14NR1-4 4NR91-4
1-2, 4-5, 7-8, 10-11* OFF L192 4NR1-6 14NR1-6 4NR91-6
1-2, 4-5, 7-8, 10-11* 2-3, 5-6, 8-9, 11-12 L192 4NR1-8 14NR1-8 4NR91-8
NR 3-POSITION FLUSH-PANEL MOUNT ROCKERS ORDER GUIDE
Circuits Made With Toggle At:
Termination Style
No.
of
Poles Ident. Lug
Position Center
Positon Opposite Lug
Position UL Rating
Code Screw Solder Q-C
1-2 OFF 2-3 L191 1NR1-1 11NR1-1 1NR91-1
1 1-2* OFF 2-3 L192 1NR1-5 11NR1-5 1NR91-5
1-2* OFF 2-3* L192 1NR1-7 11NR1-7 1NR91-7
NONE** OFF 2-3 L191 1NR1-21 11NR1-21 1NR91-21
NONE** 1-2 2-3 L191 1NR1-31 11NR1-31 1NR91-31
NONE** 1-2 2-3* L192 1NR1-51 11NR1-51 1NR91-51
1-2* OFF NONE** L192 1NR1-61 11NR1-61 1NR91-61
1-2, 4-5 OFF 2-3, 5-6 L191 2NR1-1 12NR1-1 2NR91-1
2 1-2, 4-5* OFF 2-3, 5-6 L192 2NR1-5 12NR1-5 2NR91-5
1-2, 4-5* OFF 2-3, 5-6* L192 2NR1-7 12NR1-7 2NR91-7
NONE* OFF 2-3, 5-6 L191 2NR1-21 12NR1-21 2NR91-21
NONE** 1-2, 4-5 2-3, 5-6 L191 2NR1-31 12NR1-31 2NR91-31
NONE** 1-2, 4-5 2-3, 5-6* L192 2NR1-51 12NR1-51 2NR91-51
1-2, 4-5* OFF NONE** L192 2NR1-61 12NR1-61 2NR91-61
1-2, 4-5 1-2, 4-5 2-3, 5-6 L191 2NR1-12 12NR1-12 2NR91-12
1-2, 4-5* 1-2, 5-6 2-3, 5-6 L192 2NR1-50 12NR1-50 2NR91-50
1-2, 4-5* 1-2, 5-6 2-3, 5-6* L192 2NR1-70 12NR1-70 2NR91-70
1-2, 4-5, 7-8, 10-11 OFF 2-3, 5-6, 8-9, 11-12 L191 4NR1-1 14NR1-1 4NR91-1
4 1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12 L192 4NR1-5 14NR1-5 4NR91-5
1-2, 4-5, 7-8, 10-11* OFF 2-3, 5-6, 8-9, 11-12* L192 4NR1-7 14NR1-7 4NR91-7
NONE* OFF 2-3, 5-6, 8-9, 11-12 L191 4NR1-21 14NR1-21 4NR91-21
NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12 L191 4NR1-31 14NR1-31 4NR91-31
NONE** 1-2, 4-5, 7-8, 10-11 2-3, 5-6, 8-9, 11-12* L192 4NR1-51 14NR1-51 4NR91-51
1-2, 4-5, 7-8, 10-11* OFF NONE** L192 4NR1-61 14NR1-61 4NR91-61
1-2, 4-5, 7-8, 10-11 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 L191 4NR1-12 14NR1-12 4NR91-12
1-2, 4-5, 7-8, 10-11* 2-3, 4-5, 7-8, 11-12 2-3, 5-6, 8-9, 11-12 L192 4NR1-50 14NR1-50 4NR91-50
1-2, 4-5, 7-8, 10-11* 2-3, 4-5 2-3, 5-6, 8-9, 11-12* L192 4NR1-70 14NR1-70 4NR91-70
* These positions are momentary. All others are maintained.
** Toggle lever is blocked from these products. Toggle becomes 2-position, with center being one extreme position.
TERMINAL CIRCUIT IDENTIFICATION
Terminal identification numbers referenced in the order guides
are molded into the switch base.
These numbers indicate which circuits are made in each rocker
position (e.g. ‘‘1-2’’ refers to circuit closure through terminals1
and 2).
Manuals
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Manual Switches NR Series
Seated Rocker Switches
56 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
MOUNTING DIMENSIONS
(For reference only)
Flush Panel Above Panel
Quick Connect Terminals
Solder Terminals
Panel Cutout
Terminal Circuit Identification
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Manual Switches NT/NR Series
Flat Base Sealed Toggles and Rockers
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 57
UL AND CSA ELECTRICAL RATINGS
Rating Code* Electrical Rating
L192 10 amps, 125, 250, 277 VAC; 14Hp, 125 VAC; 12Hp, 250, 277 VAC; 3 amps,
125 VAC
‘‘
L’’
L191 15 amps, 125, 250, 277 VAC; 12Hp, 125 VAC; 1 Hp, 250, 277 VAC; 5 amps,
125 VAC
‘‘
L’’
ELECTRICAL RATINGS
In Amperes
115 Volts AC
28 Volts DC 115 VDC 250 VDC 60 & 400 Hz 230 VAC
Rating
Code Ind. Res. Lamp Res. Res. Ind. Res. Lamp Res.
1 12 20 5 0.75 0.5 10 15 3 6
2 10 15 4 0.75 0.5 7 15 2 6
3 15 20 7 0.75 0.5 15 15 4 6
4 10 18 5 0.75 0.5 8 11 2 6
Application Note: Honeywell MICRO SWITCH does
not
recommend the use of silver
cadmium oxide switch contacts in non-arcing loads. Non-arcing loads are generally
loads less than 12 volts and/or 0.5 amp. NT/NR switches use silver cadmium oxide
contacts.Ifyouhavespecificquestions,contacttheMICROSWITCHApplicationCen-
ter at1-800-537-6945.
FEATURES
1
Sealed switching chamber
1
1or 2-pole circuitry
1
2or3positionmaintainedandmomen-
tary action
1
Flat base with quick-connect terminals
mating connectors are available
1
Brightly colored removable rockers
1
Spring-loaded actuating mechanism
provides tactile feedback
1
High impact strength, non-tracking
case enhances electrical stability
1
Temperaturerange:–40to71°C(–40to
160°F)
1
UL Recognized, File E12252, vol. 1,
section 44
1
CSA Certified, File LR4442
GENERAL INFORMATION
MICROSWITCHNTSeriestoggleswitch-
es and NR Series rocker switches are de-
signedtomeetsevereenvironmentappli-
cation needs for rugged, cost-effective
manual switches. These flat base style
products are identical to the stepped
base style in construction and features.
The flat base allows for PC board or con-
nector use for easy wiring/connection.
The flat base NT toggle switches and NR
rocker switches are provided with quick-
connect(spade)termination.Matingcon-
nectors are available.
TERMINAL CIRCUIT IDENTIFICATION
Terminal identifications are referenced in
theorderguidestoindicatewhichcircuits
are made in each toggle position (e.g.
‘‘1-2’’ refers to circuit closure through ter-
minals1and 2).
Manuals
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Manual Switches NT Series
Flat Base Sealed Toggles
58 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
NT 2-POSITION ORDER GUIDE
Circuits Made At:
No. of
Poles Keyway
Position Opposite
Keyway UL Rating
Code Electrical
Rating Code
Catalog
Listing
Toggle Q-C
OFF 2-3 L191 1 31NT91-2
1 1-2 2-3 L191 1 31NT91-3
OFF** 2-3 L192 2 31NT91-4
1-2** OFF L192 2 31NT91-6
1-2** 2-3 L192 2 31NT91-8
OFF 2-3, 5-6 L191 3 32NT91-2
2 1-2, 4-5 2-3, 5-6 L191 3 32NT91-3
OFF** 2-3, 4-6 L192 4 32NT91-4
1-2, 4-5** OFF L192 4 32NT91-6
1-2, 4-5** 2-3, 4-6 L192 4 32NT91-8
NT 3-POSITION ORDER GUIDE
Circuits Made At:
No. of
Poles Keyway
Position Center
Position Opposite
Keyway UL Rating
Code
Electrical
Rating
Code
Catalog
Listing
Toggle Q-C
1-2 OFF 2-3 L191 1 31NT91-1
1 1-2** OFF 2-3 L192 2 31NT91-5
1-2** OFF 2-3** L192 2 31NT91-7
NONE*** OFF 2-3 L191 1 31NT91-21
NONE*** 1-2 2-3 L191 1 31NT91-31
NONE*** 1-2 2-3** L192 2 31NT91-51
1-2** OFF NONE*** L192 2 31NT91-61
1-2, 4-5 OFF 2-3, 5-6 L191 3 32NT91-1
2 1-2, 4-5** OFF 2-3, 5-6 L192 4 32NT91-5
1-2, 4-5** OFF 2-3, 5-6** L192 4 32NT91-7
NONE*** OFF 2-3, 5-6 L191 3 32NT91-21
NONE*** 1-2, 4-5 2-3, 5-6 L191 3 32NT91-31
NONE*** 1-2, 4-5 2-3, 5-6** L192 4 32NT91-51
1-2, 4-5** OFF NONE*** L192 4 32NT91-61
1-2, 4-5 1-2, 4-5 2-3, 5-6 L191 3 32NT91-12
1-2, 4-5** 1-2, 5-6 2-3, 5-6 L192 4 32NT91-50
1-2, 4-5** 1-2, 5-6 2-3, 5-6** L192 4 32NT91-70
** These positions are momentary. All others are maintained.
*** Toggle lever is blocked from these positions. Toggle becomes 2-position, with center being one extreme
position.
MATING CONNECTORS ORDER GUIDE
Description Catalog Listing
2-pole connector 19PA168-NT
1-pole connector, same package size as 2-pole connector 19PA169-NT
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Manual Switches NR Series
Flat Base Sealed Rockers
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 59
NR 2-POSITION ORDER GUIDE
Circuits Made At:
No. of Poles Keyway Position Opposite
Keyway UL Rating
Code
Catalog
Listing
Rocker* Q-C
OFF 2-3 L191 31NR91-2
1 1-2 2-3 L191 31NR91-3
OFF** 2-3 L192 31NR91-4
1-2** OFF L192 31NR91-6
1-2** 2-3 L192 31NR91-8
OFF 2-3, 5-6 L191 32NR91-2
2 1-2, 4-5 2-3, 5-6 L191 32NR91-3
OFF** 2-3, 4-6 L192 32NR91-4
1-2, 4-5** OFF L192 32NR91-6
1-2, 4-5** 2-3, 4-6 L192 32NR91-8
NR 3-POSITION ORDER GUIDE
Circuits Made At:
No. of
Poles Keyway
Position Center
Position Opposite
Keyway UL Rating
Code
Catalog
Listing
Rocker* Q-C
1-2 OFF 2-3 L191 31NR91-1
1 1-2** OFF 2-3 L192 31NR91-5
1-2** OFF 2-3** L192 31NR91-7
NONE*** OFF 2-3 L191 31NR91-21
NONE*** 1-2 2-3 L191 31NR91-31
NONE*** 1-2 2-3** L192 31NR91-51
1-2** OFF NONE*** L192 31NR91-61
1-2, 4-5 OFF 2-3, 5-6 L191 32NR91-1
2 1-2, 4-5** OFF 2-3, 5-6 L192 32NR91-5
1-2, 4-5** OFF 2-3, 5-6** L192 32NR91-7
NONE*** OFF 2-3, 5-6 L191 32NR91-21
NONE*** 1-2, 4-5 2-3, 5-6 L191 32NR91-31
NONE*** 1-2, 4-5 2-3, 5-6** L192 32NR91-51
1-2, 4-5** OFF NONE*** L192 32NR91-61
1-2, 4-5 1-2, 4-5 2-3, 5-6 L191 32NR91-12
1-2, 4-5** 1-2, 5-6 2-3, 5-6 L192 32NR91-50
1-2, 4-5** 1-2, 5-6 2-3, 5-6** L192 32NR91-70
* Does not include rocker button. Order separately from chart.
** These positions are momentary. All others are maintained.
*** Toggle lever is blocked from these positions. Toggle becomes 2-position, with center being one extreme
position.
MATING CONNECTORS ORDER GUIDE
Description Catalog Listing
2-pole connector 19PA168-NT
1-pole connector, same package size as 2-pole connector 19PA169-NT
ELECTRICAL RATING
L191: 15 amps,125, 250, 277 VAC; 12Hp,
125 VAC; 1 Hp, 250, 277 VAC; 5
amps,125 VAC ‘‘L’’
L192: 10 amps,125, 250, 277 VAC;14Hp,
125 VAC; 12Hp, 250, 277 VAC; 3
amps,125 VAC ‘‘L’’
TERMINAL CIRCUIT
IDENTIFICATION
Terminal identifications are referenced in
theorderguidestoindicatewhichcircuits
are made in each toggle position (e.g.,
‘‘1-2’’ refers to circuit closure through ter-
minals1and 2).
Top specify above-panel mount rock-
ers: add 4(after the ‘‘NR’’) to specify the
above panel version. Example: 31NR91-5
becomes 31NR491-5.
ROCKER BUTTONS ORDER GUIDE
Rocker
Color Catalog
Listing
White 12PA12-W
Red 12PA12-R
Yellow 12PA12-Y
Black 12PA12-BK
Green 12PA12-G
Blue 12PA12-BL
Manuals
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Manual Switches NT/NR Series
Flat Base Sealed Toggles and Rockers
60 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
MOUNTING DIMENSIONS (For reference only)
Toggle Switches Rocker Switches, Above Panel
Rocker Switches, Flush Panel
Courtesy of Steven Engineering, Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Obsolete
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Courtesy of Steven Engineering, Inc.-230 Ryan Way, South San Francisco, CA 94080-6370-Main Office: (650) 588-9200-Outside Local Area: (800) 258-9200-www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 3
INDICATOR PUSHBUTTON
SELECTOR SELECTOR-PUSH
2-3-4 POSITION 2-3-4 POSITION
MULTI-LIGHT OILTIGHT CONTROLS
CMC square, multi-light controls are ideal for process control
panels.Theyareavailablewithselector,pushbutton,andselect-
or-push actuators, and mechanical or electronic duty contact
blocks.
1
Indicators, pushbuttons, selectors, and selector-push units
1
Mechanical and electronic duty contact blocks
1
Contact blocks tandem mount behind operator
1
More circuitry control than with any other control by using
four plunger adapter kit
1
Legend plates with legending in square or diagonal formats
1
Bright, lighted displays with good contrast for easy
identification
1
Square shape is compatible with other panel controls
1
Rotary cam-actuated contact blocks
1
NEMA13, oiltight and dusttight
1
CSA certified no. LR57326
1
UL listed file no. E37138
TABLE OF CONTENTS
CMC Multi-light Oiltight Controls
Contact blocks ..................................... 4
Four plunger adapter kit ............................. 5
Ordering guidelines ................................. 6
Terminal construction for lamp operation ............... 6
Indicators and pushbuttons .......................... 7
910 and 913 selectors ............................... 8
911and 914 selector-push units ...................... 10
Cover plates, color inserts, and legend plates ......... 12
Legend plates ..................................... 16
Typical CMC applications ........................... 18
Specification sheet ................................. 20
Legend order sheet ................................ 22
Accessories ....................................... 23
Replacement parts ................................. 24
Mounting dimensions .............................. 25
920/921rotary cam-actuated contact blocks ........ 26
Typical applications ................................ 27
Ordering information ............................... 28
Other MICRO SWITCH Solutions ..................... 30
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
SOLD TO
SENASYS LLC
888-736-2797
Multi-Light Oiltight Controls CMC Series
Indicators and Pushbuttons
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 7
1
Suitable for use in NEMA13
enclosures.
Indicator
1
Four lighted quadrants
1
Two or four transformers,120 or 240
VAC
1
Jumpers available for low voltage
applications.
1
Resistor boards available for 24V or
48V supply
1
Each lamp individually controlled
1
Cover plates, color inserts, and
legend plates are ordered separately.
Pushbutton
1
Actuate up to four 2-plunger contact
blocks in any combination
1
Lighted and unlighted versions
available
1
Two or four transformers,120 or 240
VAC
1
Jumpers available for low voltage
applications
1
Resistor boards available for 24V or
48V supply
1
Each lamp individually controlled.
1
Cover plates, color inserts, and
legend plates are ordered separately
INDICATOR CATALOG LISTING PUSHBUTTON CATALOG LISTING
908AAA-- 909AAA--
Gray Button
909BAA--
Black Button
ORDER GUIDE
Complete the last two blanks of the cata-
log listing with the terminal number,
which is colored in the table at the right.
Order incandescent cover plate, color in-
serts, and legend plate separately from
page12.
Order LED lamps and color inserts sep-
arately.
6VAC/DC - Page14
24VAC/DC - Page15
Contactblocksmaybeorderedseparate-
ly from page 4.
QUADRANT AREAS
908AAA--, 909AAA--, 909BAA--
67 Unlighted
FOUR TERMINAL UNITS use with 2 lamps
95 120VACtransformers(2)andNo.755lampsinquadrantsA&B,nothinginquadsC&D
96 120VACtransformers(2)andNo.755lampsinquadrantsC&D,nothinginquadsA&B
97 Line voltage jumpers in quadrantsA&B,nolamps, nothing in quadsC&D.Canbe
used with incandescent or LED bulbs.
98 Line voltage jumpers in quadrantsC&D,nolamps, nothing in quadsA&B.Canbe
used with incandescent or LED bulbs.
38 120VACtransformers(2)inquadrantsA&B.QuadrantsC&Dunlighted.Forusewith6
volt LED lamps and color inserts. Order from page 14.
FIVE TERMINAL UNITS use with 4 lamps
01 120 VAC transformers (4) and (4) No. 755 lamps
02 240 VAC transformers (4) and (4) No. 755 lamps
03 Line voltage jumpers (4)—Less lamps1. Can be used with incandescent or LED bulbs.
40 48 volt resistors (4) and (4) No. 1819 lamps
05 24 volt resistors (4) and (4) No. 756 lamps
15 120 VAC transformers (4). For use with 6 volt LED lamps and color inserts. Order from
page 14.
16 240 VAC transformers (4). For use with 6 volt LED lamps and color inserts. Order from
page 14.
EIGHT TERMINAL UNITS use with 4 lamps
51 120 VAC transformers (4) and (4) No. 755 lamps
52 240 VAC transformers (4) and (4) No. 755 lamps
53 Line voltage jumpers (4) less lamps1. Can be used with incandescent or LED bulbs.
90 48 volt resistors (4) and (4) No. 1819 lamps
50 24 volt resistors (4) and (4) No. 756 lamps
55 120 VAC transformers (4). For use with 6 volt LED lamps and color inserts. Order from
page 14.
56 240 VAC transformers (4). For use with 6 volt LED lamps and color inserts. Order from
page 14.
1See Page 23 for 2-28 volt lamp recommendations.
Contact MICRO SWITCH Branch Office for combinations of lamp voltages in one unit.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Four Plunger Adapter Kit
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 5
1
Exclusivefourplungeractuationforse-
lector and selector-push units.
1
Affords more circuit sequencing possi-
bilities by using all four points on the
cam.
1
Any combination of heavy duty and
electronic duty contact blocks (up to
four) may be used per operator.
Catalog Listing
PTCA
CIRCUIT SEQUENCING CONTROL
COMPARISON
2 PLUNGER ACTUATION
TURNCAM
BLOCK 1
BLOCK 2
BLOCK 3
BLOCK 4
4 PLUNGER ACTUATION
BETWEEN BLOCKS 1 & 2
TURNCAM
BLOCK 1
4 PLUNGER
ADAPTER
BLOCK 2
BLOCK 3
BLOCK 4
* 4 Plunger Adapter Kit (Catalog Listing PTCA) in-
cludestwosetsofauxiliaryandoffsetplungers.One
set is .200 inch longer than the other set in order to
match the variation in 2-circuit and 4-circuit block
depth.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Rotary Contact Blocks
26 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
ELECTRICAL INTERRUPTING
RATINGS (amperes)
The electrical ratings are 600 VAC, 250
VDCand20amperescontinuouscarryor
180 amperes for three seconds.
920/921CMC ROTARY CAM-
ACTUATED CONTACT BLOCKS
1
Up to12 positions available
1
Controls up to 24 circuits
1
Positive detent between positions
1
Mechanical memory stages
The920/921CMCseriesarehighlyversa-
tile rotary cam-actuated contact blocks
availablewithCMC selectors.Thesecon-
tact blocks are ideal for applications re-
quiringalargenumberofcontactsactuat-
ed simultaneously by one device. They
are designed for control circuits in appli-
cations such as instrumentation and
power generation.
MECHANICAL MEMORY
A special cam and slip clutch (M210) can
bespecifiedtoprovidemechanicalmem-
ory.
Drawing A
Drawing B
DrawingArepresents a threepositionse-
lector with spring return from both direc-
tions. Circuits 7 and 8 - contacts, 13-14
and15-16aretheslip(mechanicalmemo-
ry)contacts.M210istheslipclutch.Draw-
ing B is a simplified explanation of how
mechanical memory works.
1. In the center position step 1, contacts
13-14 and 15-16 are open. The switch
(drawing A) is in the normal after TRIP
position.
2. Step 2 shows the contact closures as
the knob is rotated clockwise to the
CLOSE position, (13-14 and 15-16
close).
3. Step 3 illustrates that the contacts re-
main closed after the selector knob
spring-returns to the center position.
4. In step 4, the knob is rotated counter-
clockwise to the TRIP position, open-
ing contacts13-14 and15-16.
5. This state is maintained after the knob
spring-returns to center, step 5.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Rotary Contact Blocks
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 27
TYPICAL APPLICATION 920 CMC (LOCKOUT)
Circuit Breaker
Control Switch
with Lockout
For identification ONLY
Do not build catalog listings from this information. See
next page for ordering information.
Number Degrees Start Switching
of Between Selector Position Stage
Positions Position Action Lamp Service Orientation Type
Selector
920
ATwo Position A30°AMaintained 01 A 0°Four Digit Number
BThree Position B45°02 B 30°Assigned by Freeport
CFour Position C60°BCW Spring Return 05 C 45°
DFive Position D90°CCCW Spring Return 40 D 60°
ESix Position EVarious DCW & CCW Spring Return 50 E 90°
FSeven Position ECW & CCW Spring Return and Lockout 51 F 120°
GEight Position FCW Spring Return and Lockout 52 G 135°
HNine Position 90 H 150°
JTen Position J180°
KEleven Position 03 K 210°
LTwelve Position 53 L 225°
M240°
67 N 270°
P300°
95 R 315°
96 S 330°
T345°
97 U 285°
98
Selector-Push
921
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Selector - Push Units
10 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
VV
CMC SELECTORS
1
Suitable for use in NEMA13 enclosures.
1
Accepts 4 plunger adapter kit
Example:
911 A G
Operator
911 —Grey knob
914 —Black knob
Turn Cam
Configuration
Insert the turn cam comfiguration code
from the shaded area of the chart below.
1. Matchyourcircuitrequirementsinone
cam code column in the chart below.*
2. Develop the catalog listing of the unit,
including the shaded letters of the cam
code configuration selected in step 1
from the chart below.
3. Considerpositionnumber1asthefur-
thest counter-clockwise device position.
Ordercontactblock(s)andadapterkitas
indicated in the left hand column of the
cam code selection chart.
Selector Action
2 Position 3 Position 4 Position
A Pos. 1, 2
E Pos. 2, 3
H Pos. 3, 4
L Pos. 4, 1
U Pos. 9, 12
o’clock
V Pos. 12, 3
o’clock
W Pos. 3, 6
o’clock
X Pos. 6, 9
o’clock
B Pos. 1, 2, 3
F Pos. 2, 3, 4
J Pos. 3, 4, 1
M Pos. 4, 1, 2
P Pos. 9, 12,
3 o’clock
R Pos. 12, 3,
6 o’clock
S Pos. 3, 6,
9 o’clock
T Pos. 6, 9,
12 o’clock
C Pos. 1, 2, 3, 4
no stop
D Pos. 1, 2, 3, 4
stop between
1 and 4
G Pos. 2, 3, 4, 1
stop between
2 and 1
K Pos. 3, 4, 1, 2
stop between
3 and 2
N Pos. 4, 1, 2, 3
stop between
3 and 4
Y Pos. 9, 12, 3, 6
o’clock. No.
stop.
Z Pos. 9, 12, 3, 6
o’clock. Stop
between 6 and
9
CAM CODE SELECTION CHART * ‘‘X’’ Circuit Closure
‘‘O’’ Circuit Open
Number of Positions: 2-Positions 3-Positions 4-Positions
Turn Cam: Configuration: B J G G G R L K G A R L
Orientation: 311311 1411 1 1
Push Cam Code: YA TC BB FB TB FB MA ED MC MD BC VB
Device Positions: 12 12 12 12 12 12 123 123 123 123 1234 1234
Contact1,2
block Terminal Condition
PTCC1-2 Free OX XO OX XX OX XX XOO XXO OXX XOO XXXX XOOO
Depress O O O O O X X O O X O X X O O X X O O O X O O O OXXX OOOO
3-4 Free OO OO XO OO XO OO OOO OOO XOO OOX OOOO OOOO
Depress X X X X X O O X X O X O O O X O O X X O O O X X XOOO XOOO
5-6 Free XO XO XX OX XX XX OOX OOX XXO OXX XXXX OOXO
Depress O O X O X O O X O O X O O O X O O X X O O O X O XXOX OOOO
7-8 Free OX OO OO XO OO OO OOO OOO OOX XOO OOOO OOOO
Depress O X O X O X X O X X O X X O O X O O O O X X O O OOXO OOXO
4-Plunger Adapter Kit3
PTCA For circuits below Use 4 plunger adapter kit and at least 1 block from above
PTCC1-2 Free OX XO XO XX OXO OXX XOX XXO XXXX OXOO
Depress O O O O O O O O O X O O X X O O O X O O XOXX OOOO
3-4 Free XO OO OX OX OO OXO OOO OOOO OOOO
Depress X X X X X X X X X X O X O O O X OXOO OXOO
5-6 Free XX OX XO XX XOO XXX OOX XXXX OOOX
Depress O O O X O O X O X O O O X O O O X XXXO OOOO
7-8 Free OO OO OX OO OOO OOO OXO OOOO OOOO
Depress X O X O X X O X O X O O X O X X O OOOX OOOX
Notes:
1Ordercontact blocks separately frompage4.
Only PTCC contact blocks are charted. All
other contact block alternatives may be sub-
stituted for portions of PTCC circuitry.
2Contact block PTCB, with its location arrow
alignedwiththe operator, provides the circui-
try equivalent to 1-2 and 7-8 of the PTCC
block. When PTCB is reversed (turned180°),
solocationarrows do notalignwith operator,
the circuitry obtained is equivalent to 3-4 and
5-6 of the PTCC block. PTCD with arrows
aligned,providessamecircuitas7-8ofPTCC
block.
When reversed (arrows not aligned), the cir-
cuit obtained is equivalent to 3-4 of PTCC
block. PTCE with arrows aligned, provides
same circuit as 1-2 of PTCC block. When re-
versed (arrows not aligned), the circuit ob-
tained is equivalent to 5-6 of PTCC block.
3PTCA is explained on page 5.
4Use up to 4 contact blocks with maintained
forms and up to 2 with spring return forms.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Selector-Push Units
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 11
COVER PLATE LEGEND OPERATOR BLOCKS
INSERTS PLATE
FFFJ
COMPLETE
UNIT
A
Operator
Function
AMaintained
BClockwise
spring return
from left (2 and
3 pos)
CCounterclock-
wise spring
return from right
(2 and 3 pos)
DClockwise and
counterclock-
wise spring
return to center
from left and
right (3 pos)
FUni-rotational
clockwise (4
pos. only, no
stop)
01
Lamp Terminals
and Service
67 Unlighted 5 Term. 8 Term.
4 Terminal 01 51
95 (2) 120 V transformers
and (2) No. 755 lamps in
quadrantsA&Bonly.
96 (2) 120 V transformers
and (2) No. 755 lamps in
quadrantsC&Donly.
97 (2) line voltage jumpers
in quadrantsA&B.No
lamps.
98 (2) line voltage jumpers
in quadrantsC&D.No
lamps.
Line voltage jumper versions
can use incandescent or LED
lamps.
(4) 120 V trans.
and
(4) No. 755
lamps
02 52
(4) 240 V trans.
and
(4) No. 755
lamps
05 50
(4) 24 V
resistors. (4)
No. 756 lamps
40 90
(4) 48 V
resistors. (4)
No. 1819 lamps
03 53
(4) line voltage
jumpers. No
lamps.
LED Lamp Terminals
and Service
4 Terminal 5 Term. 8 Term.
38 (2) 120 V transformers in
quadrantsA&B
97 (2) line voltage jumpers
in quadrantsA&B.No
LED.
98 (2) line voltage jumpers
in quadrantsC&D.No
LED.
Order LEDs, color inserts and
covers from pages 14-15.
15 55
(4) 120V transf.
16 56
(4) 240 V transf.
03 53
(4) line voltage
jumpers. No
LED.
1
TurnCam
Orientation
Insert the cam
orientation code from
the shaded area of the
chart on the facing
page.
BB
Push Cam Code
Insert the push cam
code from the shaded
area of the chart on the
facing page.
X
Order cover plates, color
inserts, and legend
plates separately from
page12.
*Thischartlistsonlyafew oftheunlimitednumber
of the switch versions available. Contact your
nearestMICRO SWITCH BranchOfficeor Autho-
rized Distributor for those not shown.
Definition:
Springreturnis the directiontheknob is turnedby
theinternalspring force whentheoperatorreleas-
estheknob.Forexample,onatwopositionclock-
wise spring return device, the knob is turned from
position 2 to position1by the operator. When the
operatorreleases the knob, itspringreturnstopo-
sition 2 in a clockwise direction.
DEVICE POSITIONS
QUADRANT AREAS
V V V
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Selector Units
8Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
VV
CMC SELECTORS
1
Suitable for use in NEMA13 enclosures.
1
Accepts 4 plunger adapter kit
Example:
910 A E
Operator
910 —Grey knob
913 —Black knob
Cam
Insert cam code from chart below.
1. Matchyourcircuitrequirementsinone
cam code column in the chart below.*
2. Develop the catalog listing of the unit,
including the shaded letters of the cam
code configuration selected in step 1
from the chart below.
3. Considerpositionnumber1asthefur-
thest counter-clockwise device position.
Ordercontactblock(s)andadapterkitas
indicated in the left hand column of the
cam code selection chart.
Selector Action
2 Positions 3 Positions 4 Positions
A—Pos. 1, 2
E—Pos. 2, 3
H—Pos. 3, 4
L—Pos. 4, 1
U—Pos. 9, 12
o’clock
V—Pos. 12, 3
o’clock
W—Pos. 3, 6
o’clock
X—Pos. 6, 9
o’clock
B—Pos. 1, 2, 3
F—Pos. 2, 3, 4
J—Pos. 3, 4, 1
M—Pos. 4, 1, 2
P—Pos. 9, 12,
3 o’clock
R—Pos. 12, 3,
6 o’clock
S—Pos. 3, 6,
9 o’clock
T—Pos. 6, 9,
12 o’clock
C—Pos. 1, 2, 3, 4
no stop
D—Pos. 1, 2, 3, 4
stop between
1 and 4
G—Pos. 2, 3, 4, 1
stop between
2 and 1
K—Pos. 3, 4, 1, 2
stop between
3 and 2
N—Pos. 4, 1, 2, 3
stop between
3 and 4
Y—Pos. 9, 12, 3, 6
o’clock. No.
stop.
Z—Pos. 9, 12, 3, 6
o’clock. Stop
between 6 and
9
CAM CODE SELECTION CHART * ‘‘X’’ Circuit Closure
‘‘O’’ Circuit Open
2-Pos. 3-Position 4-Position
Cam: E E5DGFH H A F G
Turn Cam: Orientation: 1 2 1314 1 2 2 1
Device Positions: 12121231231231231234123412341234
Contact1
Block Terminals
PTCC1-2 (NC) X O O X X O O X X O O X O OXOXOOOOOXXXOXOOXXX
3-4 (NO) O X X O O O X O O X X OOOOXOXOOOXOOOOOXXOOO
5-6 (NC) X O O X O OXOXXOXOOOOOOXOXXOOXOXOXXOX
7-8 (NO) O X XOXOOXOOOOXXOOOOOXOOOXOXOOOOXO
PTCB
1-2 (NC) X O O X X O O X X O O X O OXOXOOOOOXXXOXOOXXX
3-4 (NO) O X XOXOOXOOOOXXOOOOOXOOOXOXOOOOXO
Rev. PTCB
3-4 (NO) O X X O O O X O O X X OOOOXOXOOOXOOOOOXXOOO
1-2 (NC) X O O X O OXOXXOXOOOOOOXOXXOOXOXOXXOX
4-Plunger
Adapter Kit PTCA2For circuits below Use 4 plunger adapter kit and at least 1 block from above
PTCC1-2 (NC) OXOXXXXOX XOOXOXOXXOXX
3-4 (NO) OOOOOOOXO OOXOXOOOOXOO
5-6 (NC) O O OXOXXOX OXXOOXOXXXXO
7-8 (NO) O X O O X OOOO XOOOOOXOOOOX
PTCB
1-2 (NC) OXOXXXXOX XOOXOXOXXOXX
3-4 (NO) O X O O X OOOO XOOOOOXOOOOX
PTCB
Rev.
3-4 (NO) OOOOXO OOXOXOOOOXOO
1-2 (NC) X O X X O X O X X O OXOXXXXO
Notes:
1Ordercontact blocks separately frompage4.
Alternative contact blocks are shown
also. When alternative contact blocks are
used, their sequencing is the same as their
portion of contact block PTCC.
2Adapter kit PTCA requires contact blocks
both
before and after the adapter spacer. Up
to two blocks may be added
both
before and
after the adapter. PTCA is explained on page
5.
3Contactblock PTCBmaybemounted with its
location arrow and that of the operator
aligned or reversed; i.e., the block may be
turned180°so location arrows do not match.
4Use up to 4 contact blocks with maintained
forms and up to 2 with spring return forms.
5For use with 2 position clockwise spring re-
turn selector only.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Selector Units
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 9
COVER PLATE LEGEND OPERATOR BLOCKS
INSERTS PLATE
FFFJ
COMPLETE
UNIT
A
Operator3,4
Function
AMaintained
BClockwise
spring return
from left (2 and
3 pos)
CCounterclock-
wise spring
return from right
(2 and 3 pos)
DClockwise and
counterclock-
wise spring
return to center
from left and
right (3 pos)
FUni-rotational
clockwise (4
pos. only, no
stop)
01
Lamp Terminals
and Service
67 Unlighted 5 Term. 8 Term.
4 Terminal 01 51
95 (2) 120 V transformers
and (2) No. 755 lamps in
quadrantsA&Bonly.
96 (2) 120 V transformers
and (2) No. 755 lamps in
quadrantsC&Donly.
97 (2) line voltage jumpers
in quadrantsA&B.No
lamps.
98 (2) line voltage jumpers
in quadrantsC&D.No
lamps.
Line voltage jumper versions
can use incandescent or LED
lamps.
(4) 120 V trans.
and
(4) No. 755
lamps
02 52
(4) 240 V trans.
and
(4) No. 755
lamps
05 50
(4) 24 V
resistors.(4)
No. 756 lamps
40 90
(4) 48 V
resistors.(4)
No. 1819 lamps
03 53
(4) line voltage
jumpers. No
lamps.
LED Lamp Terminals
and Service
4 Terminal 5 Term. 8 Term.
38 (2) 120 V transformers in
quadrantsA&B
97 (2) line voltage jumpers
in quadrantsA&B.No
LED.
98 (2) line voltage jumpers
in quadrantsC&D.No
LED.
Order LEDs, color inserts and
covers from pages 14-15.
15 55
(4) 120V transf.
16 56
(4) 240 V transf.
03 53
(4) line voltage
jumpers. No
LED.
1
Cam Orientation
Insert the cam orientation code from the
shaded area of the chart on the facing page.
The area is labeled orientation and it must be
from the same column as the cam.
X
Order cover plates, color inserts, and legend
plates separately from page12.
* Thischartlistsonlyafewoftheunlimitednumber
of switch versions available. Contact your nearest
MICRO SWITCH Branch Office or Authorized Dis-
tributor for those not shown.
Definition:
Springreturnis the directiontheknob is turnedby
theinternalspring force whentheoperatorreleas-
estheknob.Forexample,onatwopositionclock-
wise spring return device, the knob is turned from
position 2 to position1by the operator. When the
operatorreleases the knob, itspringreturnstopo-
sition 2 in a clockwise direction.
DEVICE POSITIONS
QUADRANT AREAS
V V
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Legend Plate Order Sheet
22 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Legend Plates
16 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
Three type sizes are offered in either
black or white lettering for custom leg-
ends on blank legend plates. A guide to
legend area character counting is shown
in the chart below. Stay within the limits
spelledoutinthechartfornumberoflines
and characters.
To order custom legend plates, Form
62098isprovidedonpage22.Seeexam-
ple of a completed form on page17.
CATALOG LISTINGS
Operator-
Indicator Indicator
907 AUS 907 BUS
LEGEND STYLE AND SIZES
Sizes available in full capital alphabetic and numeric characters are:
9/64 13/64 5/16
.141N.203N.313N
3,57mm 5,16mm 7.94mm
Characters available are:
ABCDEFGHIJKLMNOPQRSTUVWXYZ
.,’#/()+–’’%&
0123456789
1
21
43
41
32
3
Additional characters available only in .141 (3,57) and .203 (5,16) sizes are:
#*—°→∞
‘‘
’’ 18385878
I II III IV V VI VII VIII IX X
Na Cl H2OO
2
CUSTOM LEGEND AREAS
Max. No.
Form of Max. No. Max. Total
Number Characters of Lines Caracters
in Per Line of Each Per
Shaded Letter (Include Shaded Shaded
Area Height Spaces) Area Area
1964 19 7 133
1364 13 6 78
516 84 32
2
9
64 19 3 57
1364 13 3 39
516 82 16
3
9
64 93 27
1364 63 18
5
16 32 6
4
9
64 19 2* 38
1364 13 2* 26
516 81 8
5
9
64 12 1 12
1364 81 8
5
16 51 5
6
9
64 92* 18
1364 62* 12
5
16 31 3
7
9
64 91 9
72 14
1316 61 6
Indicators 4 2 8
Only
516 41 4
Indicators
Only
8964 71 7
52 10
1364 41 4
The shaded areas shown below indicate the selections available for divi-
sion of the legend display area. After determining the form number, read
thelettersize, maximumnumberof charactersandlines fromthecharton
the left.
INDICATORS 907 AUS
OPERATOR-INDICATORS 907 BUS
INDICATORS OPERATOR-INDICATORS
907 AUS 907 BUS
DIAGONAL
LEGEND PLATES
NOTE: 2 LINE LEGENDS ARE 2 LETTERS SHORTER
PER LINE THAN SINGLE LINE LEGENDS
*Legend plate areas 4 and 6 will accept a third line. Maximum number of characters is 5 for
964Nand 3 for1364Nwhere marked.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Legend Order Sheet
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 17
Completed Sample
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Specification Sheet
20 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
Customcircuitcontrolforselectorandse-
lector-push units
Forassistance indeterminingyourcircuit
requirements for selector and selector-
push units, fill out a CMC Specification
Sheet (shown here) and submit it to the
MICRO SWITCH Application Center, or
Fax to (815) 235-6545. Your circuit re-
quirementswillbeanalyzed,andtheform
will be returned to you filled out.
Thecompletedformwillincludeacatalog
listing of the unit that will provide the con-
trol you require along with contact block
catalog listings. The completed form will
also include contact block terminal con-
nections for wiring the circuits you spec-
ified. Additional forms (FO-62783-B) are
available on request.
Follow these steps to fill out a Specifica-
tion Sheet: (Refer to the example on this
page.)
1. Mark an ‘‘X’’ where a circuit is to be
closed under ‘‘Device Position.’’ The
formmaybeusedforany2,3,or4po-
sition unit. Cross out the unused posi-
tion columns.
1.1 For selector-push units, mark an
‘‘X’’ where circuit is closed in either (or
both) the FREE and DEPRESS condi-
tion in each Device Position.
1.2Forselectors,thereisnoDEPRESS
knobfunction,andtheDEPRESSlines
should be crossed out.
2. Note under ‘‘Circuit’’ if any circuits are
to be controlled with electronic duty
contact blocks. Heavy duty contact
blocks will be specified unless other-
wise noted.
3. Indicate choice of construction de-
tails; i.e.,120 or 240 volt transformers,
low voltage jumpers, 24 or 48 volt re-
sistors.Checkwhether 4,5,or 8 termi-
nal construction is desired, main-
tained or spring return action, and
other control specifications, if
applicable.
NOTE: For 125VDC applications, use line
voltagejumpers with customer supplied ex-
ternally mounted dropping resistors. Lamp
supply voltage must not exceed 28 volts.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Specification Sheet
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 21
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Cover Plates, Color Inserts, and Legend Plates
12 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
FAST ASSEMBLY LEGEND DISPLAY
The four selected color inserts snap into
thelegendplate. Thissub-assemblythen
snapsintothecoverplatetocompletethe
front-of-panel assembly.
FOR INDICATORS
COVER PLATE
LEGEND PLATE
COLOR INSERTS
FOR OPERATOR
INDICATORS
COVER PLATE
LEGEND PLATE
COLOR INSERTS
COVER PLATES AND COLOR
INSERTS
Coverplatesand color insertsareoffered
together in one package under a single
catalog listing. The four color inserts can
bepositionedinanyofthefourquartersof
the total display area.
Any color combination you desire is in-
cludedin thischart.Thechartisarranged
inthefollowing order:4same colors, 3F
1 colors, 2 F2 colors, 2 F1F1 colors,
and1F1F1F1 colors.
Thecoverplateslistedinthetableshavea
graypaintededge.Plateswithedgesoth-
erthangray may beorderedby substitut-
inganyofthefollowingfourdigitsinplace
of the first four digits in the tables. Exam-
ple: 906A gray edge or 906E black
edge. Listings are completed from the
next page.
Edge Operator-
Color Indicator Indicator
Gray 906A 906B
Chrome 906C 906D
Black 906E 906F
Unpainted 906G 906H
Red 906J 906K
White 906N 906P
CMC LEGEND PLATES
Legend plates are transparent plastic
parts on which word messages are dis-
played.
BLANK PLATES
Blank legend plates are available for cus-
tomers preferring to do their own hot
stamping, etching, engraving, or silk
screening of legend plates. Drafting my-
larorfilmpositivescanalsobepositioned
on the legend plate for custom panel ap-
pearance.
LEGENDED
Legend plates are offered with lettering
positionedhorizontally,vertically,ordiag-
onally in combinations of black and
whiteletteringincombinationsofthree
different type sizes and the message
the customer specifies. (See character
count chart, page 16.) These plates are
ordered on Custom Legend Form on
page 22.
See completed sample page17.
LEGEND CONTRAST
For maximum visibility in both the lighted
and unlighted condition, the chart below
is recommended as a guide.
Color Legend Lettering
Snap in
Inserts White Black
Amber X X
Blue X
Green X
Red X
White X
Yellow X
BLANK LEGEND PLATES
INDICATOR OPERATOR
907AYY100 907BYY100
LEGENDED PLATES
907AUS 907BUS
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Gray Cover Plate and Color Insert Color Guide / Incandescent Lamps
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 13
COLOR CODE: A—Amber B—Blue G—Green R—Red W—White Y—Yellow K—Black
Cover Plate & Color Cover Plate & Color Cover Plate & Color Cover Plate & Color
Inserts For Indicator Inserts For Operator Inserts For Indicator Inserts For Operator
Units Only Color Code Indicator Units Units Only Color Code Indicator Units
906 AAF AAAA 906 BAF
906 AAD BBBB 906 BAD
906 AAC GGGG 906 BAC
906 AAA RRRR 906 BAA
906 AAE WWWW 906 BAE
906 AAB YYYY 906 BAB
906 AEH AAAB 906 BEH
906 AEK AAAG 906 BEK
906 AEJ AAAR 906 BEJ
906 AED AAAW 906 BED
906 AFG AAAY 906 BFG
906 AFD BBBA 906 BFD
906 AFC BBBG 906 BFC
906 AFA BBBR 906 BFA
906 AEE BBBW 906 BEE
906 AFB BBBY 906 BFB
906 AEZ GGGA 906 BEZ
906 AEX GGGB 906 BEX
906 AEG GGGR 906 BEG
906 AEY GGGW 906 BEY
906 AEW GGGY 906 BEW
906 AER RRRA 906 BER
906 AEP RRRB 906 BEP
906 AEO RRRG 906 BEO
906 AEC RRRW 906 BEC
906 AEN RRRY 906 BEN
906 AEM WWWA 906 BEM
906 AEF WWWB 906 BEF
906 AEA WWWG 906 BEA
906 AEL WWWR 906 BEL
906 AEB WWWY 906 BEB
906 AFE YYYA 906 BFE
906 AEU YYYB 906 BEU
906 AET YYYG 906 BET
906 AES YYYR 906 BES
906 AEV YYYW 906 BEV
906 ABN AABB 906 BBN
906 ABM AAGG 906 BBM
906 ABL AARR 906 BBL
906 ABP AAWW 906 BBP
906 AJF AAKK 906 BJF
906 ABQ AAYY 906 BBQ
906 ABH BBGG 906 BBH
906 ABC BBRR 906 BBC
906 ABK BBWW 906 BBK
906 AJD BBKK 906 BJD
906 ABF BBYY 906 BBF
906 ABB GGRR 906 BBB
906 ABJ GGWW 906 BBJ
906 AJC GGKK 906 BJC
906 ABE GGYY 906 BBE
906 ABD RRWW 906 BBD
906 AJA RRKK 906 BJA
906 ABA RRYY 906 BBA
906 AJE WWKK 906 BJE
906 ABG WWYY 906 BBG
906 AJB YYKK 906 BJB
906 AGZ AABG 906 BGZ
906 AGX AABR 906 BGX
906 AGY AABW 906 BGY
906 AHL AABY 906 BHL
906 ADG AAGR 906 BDG
906 ADW AAGW 906 BDW
906 AHK AAGY 906 BHK
906 ADX AARW 906 BDX
906 AHJ AARY 906 BHJ
906 AHM AAWY 906 BHM
906 AGV BBAG 906 BGV
906 AGS BBAR 906 BGS
906 AGW BBAW 906 BGW
906 AHF BBAY 906 BHF
906 AGR BBGR 906 BGR
906 AGU BBGW 906 BGU
906 ADS BBGY 906 BDS
906 ADR BBRW 906 BDR
906 AGP BBRY 906 BGP
906 AGT BBWY 906 BGT
906 AGN GGAB 906 BGN
906 ADU GGAR 906 BDU
906 AGO GGAW 906 BGO
906 AHG GGAY 906 BHG
906 AGK GGBR 906 BGK
906 ADV GGBW 906 BDV
906 AGL GGBY 906 BGL
906 ADT GGRW 906 BDT
906 ADN GGRY 906 BDN
906 AGM GGWY 906 BGM
906 AGE RRAB 906 BGE
906 AGC RRAG 906 BGC
906 AGF RRAW 906 BGF
906 AHH RRAY 906 BHH
906 ADL RRBG 906 BDL
906 AGD RRBW 906 BGD
906 ADZ RRBY 906 BDZ
906 AGB RRGW 906 BGB
906 ADO RRGY 906 BDO
906 AGA RRWY 906 BGA
906 ADY WWAB 906 BDY
906 ADH WWAG 906 BDH
906 ADF WWAR 906 BDF
906 AHE WWAY 906 BHE
906 ADK WWBG 906 BDK
906 ADM WWBR 906 BDM
906 ADE WWBY 906 BDE
906 ADB WWGR 906 BDB
906 ADD WWGY 906 BDD
906 ADA WWRY 906 BDA
906 AHC YYAB 906 BHC
906 AHB YYAG 906 BHB
906 AHA YYAR 906 BHA
906 AHD YYAW 906 BHD
906 ADP YYBG 906 BDP
906 ADJ YYBR 906 BDJ
906 AGJ YYBW 906 BGJ
906 ADC YYGR 906 BDC
906 AGH YYGW 906 BGH
906 AGG YYRW 906 BGG
906 AKF KKYG 906 BKF
906 AKG KKYB 906 BKG
906 AKH KKYW 906 BKH
906 AKJ KKYA 906 BKJ
906 AKK KKGB 906 BKK
906 AKL KKGW 906 BKL
906 AKM KKGA 906 BKM
906 AKN KKBW 906 BKN
906 AKP KKBA 906 BKP
906 AKR KKWA 906 BKR
906 AKA KKRY 906 BKA
906 AKB KKRG 906 BKB
906 AKC KKRB 906 BKC
906 AKD KKRW 906 BKD
906 AKE KKRA 906 BKE
906 ACF ABGR 906 BCF
906 ACJ ABGW 906 BCJ
906 ACN ABGY 906 BCN
906 ACH ABRW 906 BCH
906 ACL ABRY 906 BCL
906 ACP ABWY 906 BCP
906 ACG AGRW 906 BCG
906 ACK AGRY 906 BCK
906 ACO AGWY 906 BCO
906 ACM ARWY 906 BCM
906 ACD BGRW 906 BCD
906 ACA BGRY 906 BCA
906 ACE BGWY 906 BCE
906 ACC BRWY 906 BCC
906 ACB GRWY 906 BCB
Additional variations with black inserts are available.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
LED Cover Plates and Color Inserts
14 Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
Cover plates, LEDs, and color inserts are
offered together in one package under a
single catalog listing. The four color in-
serts can be positioned in any of the four
quarters of the total display area.
Thecoverplateslistedinthetableshavea
graypaintededge.Plateswithedgesoth-
erthangray may beorderedby substitut-
ingany ofthe adjacentfourdigitsinplace
of the first four digits in the tables. Exam-
ple: 905A gray edge or 905E black
edge.
Edge Operator-
Color Indicator Indicator
Gray 905A 905B
Chrome 905C 905D
Black 905E 905F
Unpainted 905G 905H
Red 905J 905K
White 905N 905P
6 VAC/VDC LEDs, GRAY COVER PLATE AND COLOR INSERT ORDER GUIDE
COLOR CODE: G—Green R—Red W—White Y—Yellow K—Black
Cover Plate & Color Cover Plate & Color Cover Plate & Color Cover Plate & Color
Inserts For Indicator Inserts For Operator Inserts For Indicator Inserts For Operator
Units Only Color Code Indicator Units Units Only Color Code Indicator Units
905 AAA1 RRRR 905 BAA1
905 AAB1 YYYY 905 BAB1
905 AAC1 GGGG 905 BAC1
905 ABA1 RRYY 905 BBA1
905 ABB1 RRGG 905 BBB1
905 ABD1 RRWW 905 BBO1
905 ABE1 YYGG 905 BBE1
905 ABG1 YYWW 905 BBG1
905 ABJ1 GGWW 905 BBJ1
905 ACB1 RGYW 905 BCB1
905 ADA1 RYWW 905 BDA1
905 ADB1 RGWW 905 BDB1
905 ADC1 RYYG 905 BDC1
905 ADD1 YGWW 905 BDD1
905 ADN1 RYGG 905 BDN1
905 ADO1 RRYG 905 BDO1
905 ADT1 RGGW 905 BDT1
905 AEA1 GWWW 905 BEA1
905 AEB1 YWWW 905 BEB1
905 AEC1 RRRW 905 BEC1
905 AEG1 RGGG 905 BEG1
905 AEL1 RWWW 905 BEL1
905 AEN1 YRRR 905 BEN1
905 AEO1 GRRR 905 BEO1
905 AES1 RYYY 905 BES1
905 AET1 GYYY 905 BET1
905 AEV1 YYYW 905 BEV1
905 AEW1 YGGG 905 BEW1
905 AEY1 GGGW 905 BEY1
905 AFK1 GGGK 905 BFK1
905 AFL1 RKKK 905 BFL1
905 AGA1 RRYW 905 BGA1
905 AGB1 RRGW 905 BGB1
905 AGG1 RYYW 905 BGG1
905 AGH1 GYYW 905 BGH1
905 AGM1 YGGW 905 BGM1
905 AHN1 YYGK 905 BHN1
905 AHO1 YGGK 905 BHO1
905 AHP1 GGWK 905 BHP1
905 AHQ1 RWWK 905 BHQ1
905 AHS1 GWWK 905 BHS1
905 AHT1 RGGK 905 BHT1
905 AHY1 YYWK 905 BHY1
905 AJA1 RRKK 905 BJA1
905 AJB1 YYKK 905 BJB1
905 AJC1 GGKK 905 BJC1
905 AKA1 RYKK 905 BKA1
905 AKB1 RGKK 905 BKB1
905 AKD1 RKKW 905 BKD1
905 AKE1 YGKK 905 BKE1
905 AKH1 RKKW 905 BKH1
905 AKL1 GKKW 905 BKL1
905 ALH1 RGWK 905 BLH1
905 ALN1 RGYK 905 BLN1
905 ALQ1 YKWW 905 BLQ1
Abovelistingsinclude gray coverplate,4color inserts andone tofour
6VAC/DCLEDsfor all lighted quadrants. (R,G,Y). Black (K) and White
(W) color inserts are normally not lighted so LEDs are not included.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
LED Cover Plates and Color Inserts
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 15
Cover plates, LEDs, and color inserts are
offered together in one package under a
single catalog listing. The four color in-
serts can be positioned in any of the four
quarters of the total display area.
Thecoverplateslistedinthetableshavea
graypaintededge.Plateswithedgesoth-
erthangray may beorderedby substitut-
ingany ofthe adjacentfourdigitsinplace
of the first four digits in the tables. Exam-
ple: 905A gray edge or 905E black
edge.
Edge Operator-
Color Indicator Indicator
Gray 905A 905B
Chrome 905C 905D
Black 905E 905F
Unpainted 905G 905H
Red 905J 905K
White 905N 905P
24 VAC/VDC LEDs, GRAY COVER PLATE AND COLOR INSERT ORDER GUIDE
COLOR CODE: G—Green R—Red W—White Y—Yellow K—Black
Cover Plate & Color Cover Plate & Color Cover Plate & Color Cover Plate & Color
Inserts For Indicator Inserts For Operator Inserts For Indicator Inserts For Operator
Units Only Color Code Indicator Units Units Only Color Code Indicator Units
905 AAA2 RRRR 905 BAA2
905 AAB2 YYYY 905 BAB2
905 AAC2 GGGG 905 BAC2
905 ABA2 RRYY 905 BBA2
905 ABB2 RRGG 905 BBB2
905 ABD2 RRWW 905 BBD2
905 ABE2 YYGG 905 BBE2
905 ABG2 YYWW 905 BBG2
905 ABJ2 GGWW 905 BBJ2
905 ACB2 RGYW 905 BCB2
905 ADA2 RYWW 905 BDA2
905 ADB2 RGWW 905 BDB2
905 ADC2 RYYG 905 BDC2
905 ADD2 YGWW 905 BDD2
905 ADN2 RYGG 905 BDN2
905 ADO2 RRYG 905 BDO2
905 ADT2 RGGW 905 BDT2
905 AEA2 GWWW 905 BEA2
905 AEB2 YWWW 905 BEB2
905 AEC2 RRRW 905 BEC2
905 AEG2 RGGG 905 BEG2
905 AEL2 RWWW 905 BEL2
905 AEN2 YRRR 905 BEN2
905 AEO2 GRRR 905 BEO2
905 AES2 RYYY 905 BES2
905 AET2 GYYY 905 BET2
905 AEV2 YYYW 905 BEV2
905 AEW2 YGGG 905 BEW2
905 AEY2 GGGW 905 BEY2
905 AFK2 GGGK 905 BFK2
905 AFL2 RKKK 905 BFL2
905 AGA2 RRYW 905 BGA2
905 AGB2 RRGW 905 BGB2
905 AGG2 RYYW 905 BGG2
905 AGH2 GYYW 905 BGH2
905 AGM2 YGGW 905 BGM2
905 AHN2 YYGK 905 BHN2
905 AHO2 YGGK 905 BHO2
905 AHP2 GGWK 905 BHP2
905 AHQ2 RWWK 905 BHQ2
905 AHS2 GWWK 905 BHS2
905 AHT2 RGGK 905 BHT2
905 AHY2 YYWK 905 BHY2
905 AJA2 RRKK 905 BJA2
905 AJB2 YYKK 905 BJB2
905 AJC2 GGKK 905 BJC2
905 AKA2 RYKK 905 BKA2
905 AKB2 RGKK 905 BKB2
905 AKD2 RKKW 905 BKD2
905 AKE2 YGKK 905 BKE2
905 AKH2 RKKW 905 BKH2
905 AKL2 GKKW 905 BKL2
905 ALH2 RGWK 905 BLH2
905 ALN2 RGYK 905 BLN2
905 ALQ2 YKWW 905 BLQ2
Abovelistingsinclude gray coverplate,4color inserts andone tofour
24 VAC/DC LEDs for all lighted quadrants. (R,G,Y). Black (K) and
White (W) color inserts are normally not lighted so LEDs are not in-
cluded.
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Replacement Parts
24 Honeywell 1MICRO SWITCH Sensing and Control For application help: call 1-800-537-6945.
Cover Plates Operator-
Indicators Color Indicators
986 AAB 01 Gray 986 AAB 02
986 AAB 03 Black 986 AAB 04
986 AAB 05 Unpainted 986 AAB 06
986 AAB 09 Red 986 AAB 10
986 AAB 13 White 986 AAB 14
986 AAB 07 Chrome 986 AAB 08
Bulk Packed Cover Plates
for Indicators
Cover plates for 20 CMC
indicators are offered.
Bulk Packed Cover Plates
for Operator-Indicators
Plates for 40 CMC operator-
indicators are offered.
Specify in multiples of 20 Specify in multiples of 40
986 AAB 01-BP 986 AAB 02-BP
986 AAB 03-BP 986 AAB 04-BP
986 AAB 05-BP 986 AAB 06-BP
986 AAB 09-BP 986 AAB 10-BP
986 AAB 13-BP 986 AAB 14-BP
986 AAB 07-BP 986 AAB 08-BP
Individual Color Inserts for Incandescent
Each insert covers 14of total display four required per
CMC unit. Operator-
Indicators Color Indicators
986 AAA 01 Red 986 AAA 02
986 AAA 03 Yellow 986 AAA 04
986 AAA 05 Green 986 AAA 06
986 AAA 07 Blue 986 AAA 08
986 AAA 09 White 986 AAA 10
986 AAA 11 Amber 986 AAA 12
986 AAA 13 Black3986 AAA 14
Bulk Packed for Indicators
Individual color inserts (one
color) for 5 CMC indicators
are offered.
Bulk Packed for Operator-
Indicators
Color inserts (one color) for
10 CMC operator-indicators
are offered.
Specify in multiples of 20 Specify in multiples of 40
986 AAA---BP 986 AAA---BP
Insert number of color above.
Individual Color Inserts for LEDs Operator-
Indicators Color Indicators
985AAA01 Red 985AAA02
985AAA03 Yellow 985AAA04
985AAA05 Green 985AAA06
986AAA09 White2986AAA10
986AAA13 Black3986AAA14
REPLACEMENT LAMPS
Industry No. Catalog
Description Voltage Listing
755 6 PTZ40
756 12 PTZ66
1819 24 PTZ67
LED, Red 6VAC/DC PTZ69
LED, Green 6VAC/DC PTZ70
LED, Yellow 6VAC/DC PTZ68
LED, Red 24VAC/DC PTZ78
LED, Green 24VAC/DC PTZ79
LED, Yellow 24VAC/DC PTZ71
‘‘O’’ Ring Seal
For operator-indicators
only 986 BAA 04
Panel Seal
For all units986 BAA 03
Lamp Holder
908 909 thru 914
Indicator Operator-
Only Indicators
986 BAA 05 986 BAA 06
Lamp Box Without
Lamp Hardware
910 Selector 911 Selector- 908
Series Push Series Indicators
986 BAA 24 986 BAA 25 986 BAA 27
Knobs1
Replacement 910 Series 913 Series
Knob Packet For Gray Knob Black Knob
Selector, Positions 1-2-3-4 986BAA15 986BAA20
Selector, Positions 9-12-3-6 o’clock 986BAA17 986BAA22
Replacement 911 Series 914 Series
Knob Packet For Gray Knob Black Knob
Selector-push, Position 1-2-3-4 986BAA16 986BAA21
Selector-push, Positions 9-12-3-6 o’clock 986BAA18 986BAA23
Notes: 1, Knob packets include knob, shaft, and O-ring seal.
2, White inserts not recommended for illumination by LEDs.
3, Black inserts not suitable for illumination.
Voltage Control
For Lamp
Individual Units
986 BAA 01
120 VAC transformer
986 BAA 02
240 VAC transformer
986 BAA 07
Low voltage jumper
986 BAA 08
48 volt resistor
986 BAA 14
24V resistor
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Contact Blocks
4Honeywell 1MICRO SWITCH Sensing and Control For application help: call1-800-537-6945.
1
PTC heavy duty and electronic duty
contact blocks
1
Tandem mounting in any combination
up to four contact blocks per operator.
(Two blocks on spring return devices.)
1
Exclusive four plunger adapter kit may
be used with selector and selector-
push units for greater circuit flexibility.
HEAVY DUTY UL/CSA Listed
Heavy duty contact blocks contain fine
silver, butting-type contacts. Terminals
are angled 30°for easy screwdriver ac-
cess to terminal screws. Screws contain
self-liftingpressureplatesfor easywiring.
Holds bare wires of12 to16 gauge, either
singly or two wires of same or adjacent
size. Crimp on spade or ring lugs can be
used. Base of contact block has marked
pad for pencil identification of the control
from back of panel.
TWO CIRCUIT BLOCKS ORDER GUIDE
Gold
Butting Contacts Silver Plated
Cata- Cata-
log log
Description Symbol Listing Listing
1NC-1NO PTCBPTCT
1NO PTCD
1NC PTCE
1NO-1NO PTCF
1NC-1NC PTCG
For AC use only. Overlapping PTCJ
For use with 909 LONC-
pushbuttons. ECNO
For other appli- Sequencing PTCK
cations contact ECNO-NO
MICRO SWITCH.
LO Jlate opening EC Jearly closing
FOUR CIRCUIT BLOCKS ORDER GUIDE
Gold
Butting Contacts Silver Plated
Cata- Cata-
log log
Description Symbol Listing Listing
2NC-2NO PTCCPTCW
1NC PTCH
1NO
1NC PTCU
1NO
ELECTRICAL RATINGS
AC Volts DC Volts
35% Power Factor Inductive Load
Continuous
Current
10 Amps. Carry 120 240 480 600 125 250
Normal Inrush
Current in Amps. 60 30 15 12
Normal Break
Current in Amps. 6 3 1.5 1.2 2.2 0.55
ELECTRONIC DUTY
Electronic duty contact blocks contain sliding contacts for re-
liable operation on electrical loads where thermal cleaning ac-
tionisnotpresent.Theseblocksareofferedwithsilvercontacts
forlow energyapplications orgold contactsfor solidstatemilli-
volt and milliamp dry circuits. Terminals are combination .187 x
.021inch quick connect plated for soldering.
SILVER GOLD
Sliding Contacts Silver Gold
Cata- Cata-
log log
List- List-
Description Symbol ing ing
4NC-4NO PTCLPTCP
2NC (Left half PTCMPTCR
2NO of 2 plunger
version.)
2NC (Right half PTCNPTCS
2NO of 2 plunger
version.)
ELECTRICAL RATINGS
Standard Duty
Sliding Silver Contacts
AC Volts DC Volts
35% Power Inductive
Factor Load
Continuous Current
5 Amps. Carry 120 220 125 250
Normal Inrush Current in Amps. 30 15
Normal Break in Amps. 3 1.5 1.1 .5
Gold Contacts
Maximum Resistive Loads
Maximum Volts in Amps.
28 VDC 1 Amp. Resistive
125 VAC .5 Amp Resistive
Initial contact resistance—.006 ohm average
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Accessories
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 23
Not all of the accessories listed here are
available from MICRO SWITCH. Be sure
to order from the suggested manufactur-
er for each accessory.
COLOR FILTERS FOR LAMPS
Foruseovertypelampsasfurnishedwith
CMC transformer units. Projects color in-
dicated when used with white color in-
serts and high ambient light level lamps
shown at right.
LAMP INFORMATION
120VACand240VACtransformerunits
are equipped with four T-3 1/4 #755
lamps. The #755 lamp has a 6.3 volt rat-
ing and is readily obtainable from all in-
dustrialorautomotivesupplycompanies.
These same units will accommodate the
#1847 lamp. Replacement #755 lamps
can be ordered as PTZ40.
24 volt or 48 volt resistor units are sup-
plied with lamps. 48 volt units are
equipped with GE #1819 lamps rated at
28 volts. 24 volt units are equipped with
#756 lamps rated at 14 volts. Replace-
ment #756 lamps can be ordered as
PTZ66 and #1819 lamps can be ordered
at PTZ67.
CMC units containing line voltage
jumpers are not supplied with lamps.
Theseunits aredesigned foruse withany
5 through 28 volt lamp listed.
If a lamp other than those listed is used,
the lamp must be limited to 1 watt per
quadrant.
QUICK CONNECTORS
Available from suppliers shown (not sold
by MICRO SWITCH)
ENCLOSURES FOR CMC
Numerous panel manufacturers build
cabinets, panelboards or enclosures for
usewithCMC.YourlocalMICROSWITCH
Branch Office or Authorized Distributor
can assist you with information on local
availability of enclosures.
PANEL PUNCH FOR CMC
A2
N(50,8mm) square panel punch
(GreenleeModel731M)forCMCismanu-
factured by Greenlee Tool Co., Rockford,
Illinois. Use in conjunction with a Green-
lee No. 7646 hydraulic punch driver.
Manufacturer Color Lamp Filters
Amber Red Green
APM, Englewood, N.J. 1813/8 A-2 1813/8 R-4 1813/8 G-1
T–314LAMP INFORMATION
Ambient Light Level
High
Lamp Current Life Medium 24 FT—C
Type Voltage Amps (Hrs) 5-25 FT—C and Up
1850 5.0 .09 1,500 X
756 14.0 .08 15,000 X
1819 28.0 .04 2,500 X
1847 6.3 .15 5,000 X
47 6.3 .15 3,000 X
755 6.3 .15 20,000 X
T–314LED INFORMATION
LED Color Voltage
V AC/DC Current Amps
(Nominal) Luminous
Intensity (MCD)
White/Yellow 6 .06 75
White/Yellow 24 .02 75
Green 6 .06 75
Green 24 .02 75
Red 6 .06 85
Red 24 .02 85
MCD Millicandlea
FOR ELECTRONIC DUTY CONTACT BLOCKS
(Either silver or gold contacts)
Range of Straight—No
Manufacturer Wire Size Insulation Flag
AMP 20-16 42452-1 or 42486-1 or
42452-2 42800-1
AMP 18-14 62016-2
HOLE PLUG
Contains Oiltight Seal
2.25N(57,2mm) +2.25N(57,2mm)
986CAA01Gray
SWITCH GUARD
Guard consists of cover plate and trans-
parent cover. Switch cannot be operated
when cover guard is closed helping pre-
vent accidental operation. Guard can be
used on 909, 910 and 911 series oper-
ators. Extends 1.52 in. (38,5 mm) from
panel.
Catalog Listing 986DAA01
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com
Multi-Light Oiltight Controls CMC Series
Mounting Dimensions
For application help: call1-800-537-6945. Honeywell 1MICRO SWITCH Sensing and Control 25
Note: The location arrow on the contact
block must be lined up with the arow on
the operator, except as noted for the
PTCB block on the ordering pages.
CMC WEIGHT
Indicators and operator-indicators (in-
cludescoverplate, legend plate, andcol-
or inserts). With transformers 14 oz.
max.
Without transformers 712oz. max.
Contact blocks 2 oz. each.
4-Plunger Adapter Kit 1oz.
INDICATOR
PUSHBUTTON
SELECTOR
SELECTOR-PUSH
PANEL CUTOUT RECOMMENDATIONS
HORIZONTAL MOUNTING VERTICAL MOUNTING HORIZONTAL or VERTICAL
5 TERMINAL CONSTRUCTION 5 TERMINAL CONSTRUCTION 8 TERMINAL CONSTRUCTION
Courtesy of Steven Engineering , Inc. ! 230 Ryan Way, South San Francisco, CA 94080-6370 ! Main Office: (650) 588-9200 ! Outside Local Area: (800) 258-9200 ! www.stevenengineering.com