Digital Timer H5CX CSM_H5CX_DS_E_3_1 Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Safety Precautions (Common) on page 47. DIN 48 x 48-mm Multifunction Digital Timer/2-stage Digital Timer * Highly visible display with backlit negative transmissive LCD. * Finger-safe terminals (screw terminal block models). * Complies with IP66, NEMA4, and UL Type 4X (when using the Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter). H5CX Series H5CX-A/-L H5CX-B 1 2 2-stage Digital Timer with 6-digit display H5CX-B Multifunction Digital Timer with 4-digit display H5CX-A (standard type) H5CX-L (economy type) Contents Multifunction Digital Timer H5CX-A/-L........................................................ 2 2-stage Digital Timer H5CX-B............................................................ 35 Common to All Models Safety Precautions ........................................... 50 1 Multifunction Digital Timer H5CX-A/-L DIN 48 x 48-mm Multifunction Digital Timer with a Bright, Easy-to-view, Negative Transmissive LCD. * Programmable PV color to visually alert when output status changes (screw terminal block models). * Intuitive setting enabled using DIP switch (H5CX-A/-A11 models) and ergonomic up/down digit keys. * Twin timer in one body to meet a broader range of cyclic control application requirements as well as ON/OFF duty adjustable flicker mode. * PNP/NPN switchable DC-voltage input (H5CX-A/-A11 models). * Meet a variety of mounting requirements: Screw terminal block models, and pin-style terminal models. * Six-language instruction manual. Contents Model Number Structure .................................................................3 Ordering Information........................................................................3 Specifications ..................................................................................4 Connections.....................................................................................7 Nomenclature ..................................................................................11 Dimensions......................................................................................12 Operating Procedures .....................................................................17 Setting Procedure Guide...........................................................17 Operating Procedures (Timer Function)....................................18 Operating Procedures (Twin Timer Function)............................26 Operation in Timer/Twin Timer Selection Mode ........................31 Additional Information......................................................................32 2 H5CX-A/-L Model Number Structure Model Number Legend H5CX-@@@@-@ 1 2 3 4 5 3. Output type None: Contact output S: Transistor output 4. Supply voltage None: 100 to 240 VAC 50/60 Hz D: 12 to 24 VDC/24 VAC 50/60 Hz 5. Case color None: Black G: Light gray (Munsell 5Y7/1): Produced upon request. 1. Type classifier A: Standard type L: Economy type 2. External connection None: Screw terminals 8: 8-pin socket 11: 11-pin socket Ordering Information List of Models Output type Supply voltage Models Standard type Screw terminals Contact output 100 to 240 VAC Transistor output 12 to 24 VDC/24 VAC Economy type 11-pin socket 8-pin socket H5CX-A H5CX-A11 H5CX-L8 12 to 24 VDC/24 VAC H5CX-AD H5CX-A11D H5CX-L8D 100 to 240 VAC H5CX-AS H5CX-A11S H5CX-L8S H5CX-ASD H5CX-A11SD H5CX-L8SD Note: Depending on the wiring, unwanted current from the AC power supply may occasionally burn out internal parts. H5CX-A/-L (except for H5CXA11/-A11S) models do not have a transformer. Therefore, the power supply and input circuit are not insulated. Refer to Safety Precautions (H5CX-A/-L) on page 49 for wiring details. The power supply and input circuit for H5CX-A11/-A11S models have basic insulation. Accessories (Order Separately) Name Flush Mounting Adapter (See note 1.) Models Y92F-30 Waterproof Packing (See note 1.) Y92S-29 Track Mounting/ Front Connecting Socket P2CF-08 Back Connecting Socket 8-pin 8-pin, finger-safe type P2CF-08-E 11-pin P2CF-11 11-pin, finger-safe type P2CF-11-E 8-pin P3G-08 8-pin, finger-safe type P3G-08 with Y92A-48G (See note 2.) 11-pin P3GA-11 11-pin, finger-safe type Hard Cover Soft Cover Mounting Track P3GA-11 with Y92A-48G (See note 2.) Y92A-48 Y92A-48F1 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Note 1. Supplied with H5CX-A@ models (except for H5CX-A11@ and H5CX-L8@ models). 2. Y92A-48G is a finger-safe terminal cover attached to the P3G-08 or P3GA-11 Socket. 3 H5CX-A/-L Specifications Ratings Item Classification H5CX-A@ H5CX-A11@ H5CX-L8@ Digital timer Rated supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC (50/60 Hz)/12 to 24 VDC (permissible ripple: 20% (p-p) max.) Operating voltage range 85% to 110% rated supply voltage (12 to 24 VDC: 90% to 110%) Power consumption (See note 1.) Approx. 6.2 VA at 264 VAC Approx. 5.1 VA at 26.4 VAC Approx. 2.4 W at 12 VDC Mounting method Flush mounting Flush mounting, surface mounting, DIN track mounting External connections Screw terminals 11-pin socket Terminal screw tightening torque 0.5 N*m max. --- Display (See note 2.) 7-segment, negative transmissive LCD; Present value: 11.5-mm-high characters, red or green (programmable) Set value: 6-mm-high characters, green 7-segment, negative transmissive LCD Present value: 11.5-mm-high characters, red Digits 4 digits Time ranges 9.999 s (0.001-s unit), 99.99 s (0.01-s unit), 999.9 s (0.1-s unit), 9999 s (1-s unit), 99 min 59 s (1-s unit) 999.9 min (0.1-min unit), 9999 min (1-min unit), 99 h 59 min (1-min unit), 999.9 h (0.1-h unit), 9999 h (1-h unit) 8-pin socket Set value: 6-mm-high characters, green Timer mode Elapsed time (Up), remaining time (Down) (selectable) Input signals Signal, reset, gate Signal, reset Input method No-voltage input/voltage input (switchable) No-voltage Input ON impedance: 1 k max. (Leakage current: 5 to 20 mA when 0 ) ON residual voltage: 3 V max. OFF impedance: 100 k min. Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k) No-voltage Input ON impedance: 1 k max. (Leakage current: 5 to 20 mA when 0 ) ON residual voltage: 3 V max. OFF impedance: 100 k min. Signal, reset, gate Minimum input signal width: 1 or 20 ms (selectable, same for all input) Reset system Power resets (except for A-3, b-1, and F modes), external and manual reset Power reset Minimum power-opening time: 0.5 s (except for A-3, b-1, and F mode) Reset voltage 10% max. of rated supply voltage Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Output modes A, A-1, A-2, A-3, b, b-1, d, E, F, Z, ton or toff One-shot output time 0.01 to 99.99 s Control output SPDT contact output: 5 A at 250 VAC/30 VDC, resistive load (cos=1) Minimum applied load: 10 mA at 5 VDC (failure level: P, reference value) Transistor output: NPN open collector, 100 mA at 30 VDC max. residual voltage: 1.5 VDC max. (Approx. 1 V) Leakage current: 0.1 mA max. Output category according to EN60947-5-1 for Timers with Contact Outputs (AC-15; 250 V 3 A/AC-13; 250 V 5 A/ DC-13; 30 V 0.5 A) Output category according to EN60947-5-2 for Timers with Transistor Outputs (DC-13; 30 V 100 mA) NEMA B300 Pilot Duty, 1/4 HP 5-A resistive load at 120 VAC, 1/3 HP 5-A resistive load at 240 VAC Key protection Yes Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Ambient temperature Operating: Storage: Ambient humidity 25% to 85% -10 to 55C (-10 to 50C if timers are mounted side by side) (with no icing or condensation) -25 to 65C (with no icing or condensation) Case color Black (N1.5) Attachments Waterproof packing, flush mounting adapter, label for DIP switch settings Label for DIP switch settings None Note 1. Inrush current will flow for a short time when the power supply is turned ON. Refer to Inrush Current (Reference Values) on page 6. 2. The display is lit only when the power is ON. 4 H5CX-A/-L Characteristics Item H5CX-A@/-A11@/-L8@ Accuracy of operating time Power-ON start: 0.01% 50 ms max. Rated against set value and setting error (including Signal start: 0.005% 30 ms max. Rated against set value temperature and voltage inSignal start for transistor output model: 0.005% 3 ms max. (See note 2.) fluences) (See note 1.) If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting time passes. Insulation resistance 100 M min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts, and between non-continuous contacts Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 1,000 VAC (for H5CX-@SD), 50/60 Hz for 1 min between control output, power supply, and input circuit (2,000 VAC for models other than H5CX-@SD) 1,000 VAC, 50/60 Hz for 1 min between non-continuous contacts Impulse withstand voltage 3 kV (between power terminals) for 100 to 240 VAC, 1 kV for 24 VAC/12 to 24 VDC 4.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) for 100 to 240 VAC 1.5 kV for 24 VAC/12 to 24 VDC Noise immunity 1.5 kV (between power terminals) and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Static immunity Destruction: 15 kV Malfunction: 8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions, 2 hours each Malfunction: 10 to 55 Hz with 0.35-mm single amplitude each in three directions, 10 min each Shock resistance Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions Life expectancy Mechanical: 10,000,000 operations min. (under no load at 18,000 operations/h) Electrical: 100,000 operations min. (5 A at 250 VAC, resistive load at 1,800 operations/h) See Life-test Curve on page 6. Approved safety standards UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14, conforms to EN61812-1 (Pollution (See notes 3 and 4.) degree 2/overvoltage category III) Conforms to VDE0106/P100 (finger protection). EMC (EMI) Emission Enclosure: Emission AC mains: (EMS) Immunity ESD: Immunity RF-interference: EN61812-1 EN55011 Group 1 class A EN55011 Group 1 class A EN61812-1 EN61000-4-2: 6 kV contact discharge (level 2) 8 kV air discharge (level 3) EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3) Immunity Conducted Disturbance: Immunity Burst: EN61000-4-6: EN61000-4-4: Immunity Surge: EN61000-4-5: Immunity Voltage Dip/Interruption EN61000-4-11: 10 V (0.15 to 80 MHz) (level 3) 2 kV power-line (level 3); 1 kV I/O signal-line (level 4) 1 kV line to lines (power and output lines) (level 3); 2 kV line to ground (power and output lines) (level 3) 0.5 cycle, 100% (rated voltage) Degree of protection Panel surface: IP66 and NEMA4 (indoors), and UL Type 4X (indoors) (See note 4.) Weight H5CX-A@: Approx. 135 g, H5CX-A11@/-L8@: Approx. 105 g Note 1. The values are based on the set value. 2. The value is applied for a minimum pulse width of 1 ms. 3. To meet UL listing requirements with H5CX-L8@/-A11@ models, an OMRON P2CF-08-@ or P3G-08 Socket must be mounted on the Timer. Otherwise, H5CX-L8@/-A11@ models are considered to meet UL508 recognition requirements. 4. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X waterproofing between the H5CX and installation panel. 5 H5CX-A/-L Switching operations (x104) Life-test Curve (Reference Values) 1,000 500 100 30 VDC L/R=7 ms 50 250 VDC/30 VDC cos=1 10 250 VAC cos=0.4 0 1 2 3 4 5 Load current (A) Reference: A maximum current of 0.15 A can be switched at 125 VDC (cos=1) and a maximum current of 0.1 A can be switched if L/R is 7 ms. In both cases, a life of 100,000 operations can be expected. The minimum applicable load is 10 mA at 5 VDC (failure level: P). Inrush Current (Reference Values) Voltage Applied voltage Inrush current (peak value) Time 100 to 240 VAC 264 VAC 5.3 A 0.4 ms 24 VAC/ 12 to 24 VDC 26.4 VAC 6.4 A 1.4 ms 26.4 VDC 4.4 A 1.7 ms 6 H5CX-A/-L Connections Block Diagram (Basic insulation) Power supply circuit Output circuit (See note.) (Basic insulation) Display circuit Internal control circuit Input circuit Key switch circuit Note: Power circuit is not insulated from the input circuit, except for H5CX-A11/-A11S, which have basic insulation. I/O Functions Inputs Outputs Start signal Stops timing in A-2 and A-3 (power ON delay) modes. Starts timing in other modes. Reset Resets present value. (In elapsed time mode, the present value returns to 0; in remaining time mode, the present value returns to the set value.) Count inputs are not accepted and control output turns OFF while reset input is ON. Reset indicator is lit while reset input is ON. Gate Inhibits timer operation. (The timer will be reset if the reset input turns ON while the gate input is ON.) Control output (OUT) Outputs take place according to designated operating mode when timer reaches corresponding set value. 7 H5CX-A/-L Terminal Arrangement Confirm that the power supply meets specifications before use. 6 7 8 9 6 Gate Input use 0 V Unused Signal Gate Signal Reset Input use 0 V Reset H5CX-AS/-ASD H5CX-A/-AD 7 8 9 Unused 10 10 Unused Unused Unused Unused Unused Unused 11 12 11 12 1 1 2 13 13 3 4 2 3 4 5 5 Transistor output Contact output (-) (-) (+) (+) The power supply and input circuit are not insulated. (See note 2.) Terminals 1 and 6 of the H5CX-AD are connected internally. The power supply and input circuit are not insulated. (See note 2.) Terminals 1 and 6 of the H5CX-ASD are connected internally. H5CX-A11S/-A11SD H5CX-A11/-A11D Reset Reset Signal Signal Gate Internal circuit Gate Internal circuit 5 6 7 5 6 7 Unused 4 8 Unused 4 8 0V 3 9 10 0V 3 9 10 2 1 11 2 Contact output Unused 1 11 Transistor output Unused (-) (+) (-) (+) The power supply and input circuit of the H5CX-A11 have basic insulation. The power supply and input circuit of the H5CX-A11D are not insulated. (See note 2.) Terminals 2 and 3 of the H5CX-A11D are connected internally. The power supply and input circuit of the H5CX-A11S have basic insulation. The power supply and input circuit of the H5CX-A11SD are not insulated. (See note 2.) Terminals 2 and 3 of the H5CX-A11SD are connected internally. H5CX-L8S/-L8SD H5CX-L8/-L8D Internal circuit Internal circuit Signal Reset Signal 4 5 3 6 7 2 1 Unused Reset Contact output 8 4 5 3 6 7 2 1 0V Transistor output 8 0V (-) (+) (-) (+) The power supply and input circuit are not insulated. (See note 2.) Terminals 1 and 2 of the H5CX-L8D are connected internally. The power supply and input circuit are not insulated. (See note 2.) Terminals 1 and 2 of the H5CX-L8SD are connected internally. Note 1. Do not connect unused terminals as relay terminals. 2. The power supply and input circuit are not insulated, so unwanted current from the AC power supply may burn out internal parts. Refer to Safety Precautions (H5CX-A/-L) on page 49 for wiring details. 8 H5CX-A/-L Input Circuits Signal, Reset, and Gate Input +14 V 1 k IN Internal circuit Note: When using no-voltage input (NPN input). Input Connections The inputs of the H5CX-A@/-A11@ are no-voltage (short-circuit or open) inputs or voltage inputs. The input of the H5CX-L8@ is no-voltage input only. Note: Power circuit is not insulated from the input circuit, except for H5CX-A11/-A11S, which have basic insulation. For wiring, refer to Safety Precautions (H5CX-A/-L) on page 49. No-voltage Inputs (NPN Inputs) Contact Input Open Collector Voltage Output (Connection to NPN open collector output sensor) (Connection to a voltage output sensor) PC or sensor DC Two-wire Sensor H5CX-A@ H5CX-A11@ H5CX-L8@ H5CX-A@ H5CX-A11@ H5CX-L8@ Operate with transistor ON Operate with transistor ON H5CX-A@ H5CX-A11@ H5CX-L8@ H5CX-A@ H5CX-A11@ H5CX-L8@ Operate with relay ON Operate with transistor ON Gate input Signal input Input 0V Reset input Gate input Signal input Input 0V Reset input Gate input Signal input Input 0V Reset input Gate input Signal input Input 0V Reset input Sensor No-voltage Input Signal Levels Applicable Two-wire Sensor No-contact input Leakage current: Switching capacity: Residual voltage: Operating voltage: Short-circuit level Transistor ON Residual voltage: 3 V max. Impedance when ON: 1 k max. (the leakage current is about 12 mA when the impedance is 0 ) 1.5 mA max. 5 mA min. 3.0 VDC max. 10 VDC Open level Transistor OFF Impedance when OFF: 100 k min. Contact input Use contact which can adequately switch 5 mA at 10 V Note: The DC voltage must be 30 VDC max. 9 H5CX-A/-L Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) No-contact Input (PNP Transistor) (Connection to NPN open collector output sensor) (Connection to PNP open collector output sensor) Contact Input H5CX-A@ H5CX-A11@ H5CX-A@ H5CX-A11@ Operate with transistor ON Operate with transistor OFF Gate input Signal input Input 0V Reset input Gate input Input 0V Reset input Gate input Signal input Input Reset input 0V Signal input Sensor Sensor H5CX-A@ H5CX-A11@ Operate with relay ON Voltage Input Signal Levels High level (Input ON): Low level (Input OFF): Input resistance: 4.5 to 30 VDC 0 to 2 VDC Approx. 4.7 k Note: The DC voltage must be 30 VDC max. 10 H5CX-A/-L Nomenclature Operation Key Indicator Reset Indicator (orange) Mode Key (Changes modes and setting items) Key Protection Indicator (orange) Reset Key (Resets present value and output) Control Output Indicator (orange) Present Value (red or green (programmable) for H5CX-A models, red for H5CX-A11 /-L models) Character height: 11.5 mm Time Unit Display (Color is same as present value and set value.): (If the time range is 0 min, 0 h, 0.0 h, or 0 h 0 min, this display flashes to indicate timing operation.) Up Keys 1 to 4 Down Keys 1 to 4 Front View Front color: Black Switches Key-protect Switch (Default setting) OFF ON Set Value (green) Character height: 6 mm Set Value 1, 2 Display DIP Switch Case color: Black 1 2 3 4 5 6 7 8 ON OFF Note 1: All the pins are factory-set to OFF. 2: There is no DIP switch on the H5CX-L8@. 11 H5CX-A/-L Dimensions Note: All units are in millimeters unless otherwise indicated. Dimensions without Flush Mounting Adapter H5CX-A/-AS (Flush Mounting Models) 48x48 6 100 44.8x44.8 Note: M3.5 terminal screw (effective length: 6 mm) H5CX-AD/-ASD (Flush Mounting Models) 48x48 6 64 44.8x44.8 Note: M3.5 terminal screw (effective length: 6 mm) H5CX-A11/-A11S (Flush Mounting/Surface Mounting Models) 48x48 6 14.4 72.5 44.8x44.8 H5CX-A11D/-A11SD (Flush Mounting/Surface Mounting Models) 48x48 6 63.7 14.4 H5CX-A11D 44.8x44.8 H5CX-L8@ (Flush Mounting/Surface Mounting Models) 48x48 6 63.7 14.3 44.8x44.8 12 H5CX-A/-L Dimensions with Flush Mounting Adapter H5CX-A/-AS (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing Panel Y92F-30 (provided) Flush Mounting Adapter (51) 58 48 7.5 98.5 H5CX-AD/-ASD (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing 58 Panel Y92F-30 (provided) Flush Mounting Adapter (51) Panel Cutouts Panel cutouts areas shown below. (according to DIN43700). 48 7.5 62.5 60 min. 45 +0.6 -0 H5CX-A11/-A11S (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) Waterproof Packing 58 Panel 45 +0.6 -0 Y92F-30 (order separately) Flush Mounting Adapter 60 min. 15 min. P3GA-11 (order separately) Rear Surface Connection Socket (51) 48 7.5 98.7 H5CX-A11D/-A11SD (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) Waterproof Packing Panel Note 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operability, it is recommended that Adapters are mounted so that the gap between sides with hooks is at least 15 mm. 3. It is possible to mount timers side by side, but only in the direction without the hooks. Y92F-30 (order separately) Flush Mounting Adapter n side by side mounting P3GA-11 (order separately) Rear Surface Connection Socket (51) 58 A A = (48n - 2.5) +1 0 With Y92A-48F1 attached. A = {48n-2.5 + (n-1) x 4} +1 0 48 With Y92A-48 attached. A = (51n-5.5) +1 0 89.9 7.5 H5CX-L8@ (Adapter and Waterproof Packing Ordered Separately) Y92S-29 (order separately) Waterproof Packing) Panel Y92F-30 (order separately) Flush Mounting Adapter P3G-08 (order separately) Rear Surface Connection Socket 58 (51) 48 7.5 84.8 13 H5CX-A/-L Dimensions with Front Connecting Socket 112 H5CXA11/ -A11S 109.7 103.2 H5CXA11D/ -A11SD H5CXL8@ 100.9 P2CF-08-@ P2CF-11-@ P2CF-11-@ 90 92.3 Note: These dimensions vary with the kind of DIN track (reference value). Accessories (Order Separately) Note: All units are in millimeters unless otherwise indicated. Track Mounting/Front Connecting Socket P2CF-08 Eight, M3.5 x 7.5 sems 7.8 4.5 3 70 max. 35.4 Terminal Arrangement/ Internal Connections (Top View) Two, 4.5 dia. holes Surface Mounting Holes 4 50 max. Two, 4.5 dia. or two, M4 20.3 max. P2CF-08-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eight, M3.5 x 7.5 sems 400.2 5 7.8 4.5 3 1.3 70 max. 35.4 Two, 4.5 dia. holes 4 400.2 19 50 max. 20.3 21.5 max. 14 H5CX-A/-L Track Mounting/Front Connecting Socket P2CF-11 Eleven, 7.8 M3.5 x 7.5 sems 3 4.5 70 max. Terminal Arrangement/ Internal Connections (Top View) 35.4 Two, 4.5 dia. holes Surface Mounting Holes Two, 4.5 dia. or two, M4 4 50 max. 31.2 max. 400.2 P2CF-11-E (Finger Safe Terminal Type) Conforming to VDE0106/P100 Eleven, M3.5 x 7.5 sems 4.5 5 7.8 3 1.2 70 max. 35.4 Two, 4.5 dia. holes 4 400.2 30 50 max. Back Connecting Socket P3G-08 31.2 max. Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 45 4.9 17 P3GA-11 Terminal Arrangement/ Internal Connections (Bottom View) 27 dia. 45 25.6 45 4.5 16.3 6.2 Finger Safe Terminal Cover Conforming to VDE0106/P100 Y92A-48G (Attachment for P3G-08/P3GA-11 Socket) Twelve, 6.4 dia. holes 34 47.7 x 47.7 16.5 48 x 48 24.6 27.6 47.4 15 H5CX-A/-L Note: 1. Depending on the operating environment, the condition of resin products may deteriorate, and may shrink or become harder. Therefore, it is recommended that resin products are replaced regularly. 2. The H5CX's panel surface is water-resistive (conforming to IP66) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54 against oil. Do not, however, use the H5CX in locations where it would come in direct contact with oil. Soft Cover Y92A-48F1 Hard Cover Y92A-48 Flush Mounting Adapter (provided with models with H5CX-A/AD/AS/ASD) Y92F-30 Waterproof Packing (provided with models with H5CX-A/AD/AS/ASD) Y92S-29 Note: Order the Flush Mounting Adapter separately if it is lost or damaged. Mounting Track PFP-100N, PFP-50N Note: Use Waterproof Packing to provide a level of water protection that complies with NEMA4, UL Type 4X, or IP66 standards. Order the Waterproof Packing separately if it is lost or damaged. Depending on the operating environment, the Waterproof Packing may deteriorate, contract, or harden and so regular replacement is recommended. PFP-100N2 16 7.30.15 4.5 4.5 15 25 25 10 25 1,000 (500) (See note.) 10 350.3 270.15 350.3 25 * 15 1 25 25 15 25 25 10 1,000 27 24 1 10 29.2 1.5 Note: The values shown in parentheses are for the PFP-50N. End Plate PFP-M Spacer PFP-S 10 6.2 16 12 5 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 16 H5CX-A/-L Operating Procedures Setting Procedure Guide Settings for Timer Operation Use the following settings for all models except the H5CX-L8@. Refer to page 19 for the H5CX-L8@. When Using Basic Functions Only * * * * Basic Functions Time range (0.001 s to 999.9 h, except 9999 h and 9999min) Output mode (A, A-2, E, F) Timer mode (UP/DOWN) Input signal width (20 ms/1 ms) The settings can be performed easily with the DIP switch. For details on the setting methods, refer to page 18. 1 2 3 4 5 6 7 8 ON OFF When Using Other Time Ranges (9999 h, 9999 min) and Output Modes (A-1, A-3, b, b-1, d, and Z) When Using More Detailed Setting Items (Output Time, NPN/PNP Input Mode, Display Color, Key Protect Level) All the functions can be set with the operation keys. For details on the setting methods, refer to page 19. Setting for items other than the basic functions can be performed with the operation keys. For details on the setting methods, refer to page 19. Note: At the time of delivery, the H5CX is set for timer operation. Settings for Twin Timer Operation Use the following settings for all models except the H5CX-L8@. Refer to page 27 for the H5CX-L8@. When Using Basic Functions Only Basic Functions * Time range (0.01 s to 99 min 59 s) * ON/OFF start mode (flicker OFF start/flicker ON start) * Timer mode (UP/DOWN) * Input signal width (20 ms/1 ms) The settings can be performed easily with the DIP switch. For details on the setting methods, refer to page 26. 1 2 3 4 5 6 7 8 ON OFF When Using Other Time Ranges (999.9 min, 9999 min, 99 h 59 min, 999.9 h, 9999 h, 9.999 s) All the functions can be set with the operation keys. For details on the setting methods, refer to page 27. When Using More Detailed Setting Items (NPN/PNP Input Mode, Display Color, Key Protect Level) Setting for items other than the basic functions can be performed with the operation keys. For details on the setting methods, refer to page 27. Note: At the time of delivery, the H5CX is set for timer operation. 17 H5CX-A/-L Operating Procedures (Timer Function) Settings for Basic Functions Settings for basic functions can be performed with just the DIP switch. Be sure to set pin 1 to ON when using the DIP switch. 1 2 3 4 5 6 7 8 ON OFF Item 1 2 OFF ON DIP switch settings enable/ disable Disabled Enabled Time range Refer to the table on the right. 3 4 5 Pin 2 Pin 3 ON ON OFF ON Pin 4 Time range ON 0.001 s to 9.999 s OFF OFF 0.01 s to 99.99 s OFF OFF 0.1 s to 999.9 s OFF ON OFF 1 s to 9999 s ON ON OFF 0 min 01 s to 99 min 59 s Output mode Refer to the table on the right. OFF OFF ON 0.1 min to 999.9 min 7 Timer mode Elapsed time (UP) Remaining time (DOWN) ON OFF ON 0 h 01 min to 99 h 59 min 8 Input signal width 20 ms 1 ms OFF ON ON 0.1 h to 999.9 h 6 Note: All the pins are factory-set to OFF. Pin 5 Pin 6 Output mode OFF OFF A mode (signal ON delay (I): power reset operation) ON OFF A-2 mode: (power ON delay (I): power reset operation) Easy Confirmation of Switch Settings Using Indicators OFF ON The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 31. E mode (interval: power reset operation) ON ON F mode (accumulative: power hold operation) Note 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled. 2. Changes to DIP switch settings are enabled when the power is turned ON. (Perform DIP switch settings while the power is OFF.) 3. There is no DIP switch on the H5CX-L8@. For details on the setting methods, refer to page 19. 4. When using time ranges or output modes that cannot be set with the DIP switch, all of the settings have to be made using the operation keys. For details on the setting methods, refer to page 19. Detailed Settings After making DIP switch settings for basic functions, detailed settings (see note) can be added using the operation keys. For details, refer to page 19. Note: Output time, NPN/PNP input mode, display color, key protect level. 18 H5CX-A/-L Settings for Advanced Functions Settings that cannot be performed with the DIP switch are performed with the operation keys. Power ON Run mode For details on operations in run mode, refer to page 21. Note 1. If the mode is switched to the function setting mode during operation, operation will continue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the timer is reset (time initialized and output turned OFF). See note 1. See note 2. The characters displayed in reverse video are the default settings. 3 s min. 3 s min. When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated in will not be displayed. Set the time range using the keys. Time range s s ...... s h s For details, refer to Time Range List below. Set the timer mode using the keys. Timer mode (Elapsed time) Output mode Set the output mode using the Function setting mode (A) Output time (Remaining time) (A-1) (A-2) (A-3) keys. (b) (b-1) (d) Set each digit for the output time using the corresponding : Output hold/0.01 to 99.99 s (If the output time is set to 0.00, is displayed.) Displayed for modes A, A-1, A-2, A-3, b, and b-1 only. Input signal width Set the input signal width using the keys. (E) (F) (Z) keys. Time Range List Display Set Value 0.01 s to 99.99 s (default setting) 0.1 s to 999.9 s (20 ms) (1 ms) 1 s to 9999 s NPN/PNP input mode Set the NPN/PNP input mode using the keys. (NPN input) (PNP input) Only displayed for H5CX-A@ and H5CX-A11@ models. 0 min 01 s to 99 min 59 s 0.1 min to 999.9 min 1 min to 9999 min Display color Set the display color using the keys. 0 h 01 min to 99 h 59 min (Red) (Green) Red-green Green-red Displayed for terminal-block models (H5CX-A@) only. Key protect level Set the key protect level using the keys. 0.1 h to 999.9 h 1 h to 9999 h 0.001 s to 9.999 s (KP-1) (KP-2) (KP-3) (KP-4) (KP-5) 19 H5CX-A/-L Explanation of Functions Input Signal Width (iflt) (Setting possible using DIP switch.) Time Range (timr) (Setting possible using DIP switch.) Set the range to be timed in the range 0.000 s to 9,999 h. Settings of type ---- h (9,999 h) and ---- min (9,999 min) cannot, however, be made with the DIP switch. Use the operation keys if these settings are required. Set the minimum signal input width (20 ms or 1 ms) for signal, reset, and gate inputs. The same setting is used for all external inputs (signal, reset, and gate inputs). If contacts are used for the input signal, set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting. Timer Mode (timm) (Setting possible using DIP switch.) NPN/PNP Input Mode (imod) Set either the elapsed time (UP) or remaining time (DOWN) mode. Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page 9. Output Mode (outm) (Setting possible using DIP switch.) Set the output mode. The possible settings are A, A-1, A-2, A-3, b, b1, d, E, F, and Z. Only output modes A, A-2, E, and F can be set using the DIP switch. Use the operation keys if a different setting is required. (For details on output mode operation, refer to Timing Charts on page 22.) Display Color (colr) Set the color used for the present value. Output OFF Output ON Output Time (otim) red Red (fixed) When using one-shot output, set the output time for one-shot output (0.01 to 99.99 s). One-shot output can be used only if the selected output mode is A, A-1, A-2, b, or b-1. If the output time is set to 0.00, hold is displayed, and the output is held. grn Green (fixed) r-g Red Green g-r Green Red Key Protect Level (kypt) Set the key protect level. When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. (See note) OFF ON Note: Factory-set to OFF Key protect indicator Level Meaning Details Changing mode (See note.) Switching display during operation Reset key Up/down key KP-1 (default setting) No Yes Yes Yes KP-2 No Yes No Yes KP-3 No Yes Yes No KP-4 No Yes No No KP-5 No No No No Note: Changing mode to timer/twin timer selection mode ( MODE + 1 1 s min.) or function setting mode ( MODE 3 s min.). 20 H5CX-A/-L Operation in Run Mode When Output Mode Is Not Z Present value Set each digit for the set value using the corresponding keys. Set value When Output Mode Z Is Selected Present value Set each digit for the ON duty ratio using the corresponding (The keys for the 4th digit cannot be used.) keys. ON duty ratio Present value Set each digit for the cycle time using the corresponding keys. Cycle time Present Value and Set Value Present Value and Cycle Time (Output Mode = Z) These items are displayed when the power is turned ON. The present value is displayed in the main display and the set value is displayed in the sub-display. The values displayed will be determined by the settings made for the time range and the timer mode in function setting mode. The present value is displayed in the main display and the cycle time is displayed in the sub-display. "SET2" lights at the same time. Set the cycle time used in ON/OFF-duty adjustable flicker mode (Z). Present Value and ON Duty Ratio (Output Mode = Z) Elapsed cycle time The present value is displayed in the main display and the ON duty ratio is displayed in the sub-display. "SET1" lights at the same time. ON duty set as a percentage Set the ON duty ratio used in ON/OFF-duty adjustable flicker mode (Z) as a percentage. Up/down keys used for analog adjustment of the ON duty If a cycle time is set, cyclic control can be performed in ON/OFF-duty adjustable flicker mode simply by changing the ON duty ratio. ON time = Cycle time x ON duty ratio (%) 100 The output accuracy will vary with the time range, even if the ON duty ratio setting is the same. Therefore, if fine output time adjustment is required, it is recommended that the time range for the cycle time is set as small as possible. Cycle time Close Open ON duty (%) Output control Opening/closing valve ON duty Fully closedFully open 0%100% Examples: 1. If the cycle time is 20 s, the ON duty ratio is 31%, and the time range is 1 s to 9999 s, the ON time is given by the following: 20 (s) x 31 (%) = 6.2 (s) Rounded off to the nearest integer 100 (because of the time range setting) ON time = 6 s 2. If the cycle time is 20.00 s, the ON duty ratio is 31%, and the time range is 0.01 s to 99.99 s, the ON time is given by the following: 31 (%) = 6.200 (s) Rounded off to 2 decimal places 100 (because of the time range setting) ON time = 6.20 s 20.00 (s) x 21 H5CX-A/-L Timing Charts Timer Operation The gate input is not included in the H5CX-L8@ models. One-shot output t Sustained output Either one-shot output or sustained output can be selected. Output mode A: Signal ON delay 1 (Timer resets when power comes ON.) Timing starts when the start signal goes ON. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period. Power Start signal Gate Basic Operation Reset t t Power Control output Start signal ** input Set value Timing diagram UP Timing Output 0 Set value DOWN * Output is instantaneous when setting is 0. ** Start signal input is disabled during timing. Output mode A-1: Signal ON delay 2 (Timer resets when power comes ON.) 0 Timing starts when the start signal goes ON, and is reset when the start signal goes OFF. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. The control output is controlled using a sustained or one-shot time period. Power Start signal Gate Basic Operation Reset Power t Control output Start signal input Set value Timing diagram UP Timing Output 0 * Output is instantaneous when setting is 0. Set value DOWN 0 Output mode A-2: Power ON delay 1 (Timer resets when power comes ON.) Timing starts when the reset input goes OFF. The start signal disables the timing function (i.e., same function as the gate input). The control output is controlled using a sustained or one-shot time period. Power Start signal Gate Basic Operation Reset Power t * Output is instantaneous when setting is 0. Set value Timing diagram Timing Output Control output UP 0 Set value DOWN 0 Output mode A-3: Power ON delay 2 (Timer does not reset when power comes ON.) Timing starts when the reset input goes OFF. The start signal disables the timing function (i.e., same function as the gate input). The control output is controlled using a sustained or one-shot time period. Power Start signal Basic Operation Gate Power Reset t Control output Set value Timing diagram t t Output Timing Sustained * Output is instantaneous when setting is 0. UP 0 Set value DOWN 0 22 H5CX-A/-L . Output mode b: Repeat cycle 1 (Timer resets when power comes ON.) Sustained Output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Reset Start signal ** input Control output Timing Timing Timing Timing Output Set value UP Timing diagram 0 * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. Set value DOWN 0 One-shot Output Timing starts when the start signal goes ON. The control output is turned ON when time is up. While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Start signal ** input Reset t t Timing Timing Timing Timing Control output Output Set value Timing diagram UP * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. 0 Set value DOWN 0 Output mode b-1: Repeat cycle 2 (Timer does not reset when power comes ON.) Sustained Output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Reset Timing Control output Set value Timing diagram Output UP 0 * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. Set value DOWN 0 One-shot Output Sustained Timing Start signal ** input Timing starts when the start signal goes ON. The control output comes ON when time is up. While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Timing Reset t Control output t t t t Set value Timing diagram Sustained Timing Start signal ** input Output UP 0 Set value DOWN 0 * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. 23 H5CX-A/-L Output mode d: Signal OFF delay (Timer resets when power comes ON.) The control output is ON when the start signal is ON (except when the power is OFF or the reset is ON). The timer is reset when the time is up. Power Start signal Basic Operation Gate Power Reset Start signal ** input Timing Control output Output Set value Timing diagram UP * 0 Set value Output functions only during start signal input when setting is 0. ** Start signal input is enabled during timing. DOWN 0 Output mode E: Interval (Timer resets when power comes ON.) Timing starts when the start signal comes ON. The control output is reset when time is up. While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Reset Start signal ** input Control output Set value Timing Output UP Timing diagram 0 Set value DOWN * Output is disabled when the setting is 0. ** Start signal input is enabled during timing. 0 Output mode F: Cumulative (Timer does not reset when power comes ON.) Start signal enables timing (timing is stopped when the start signal is OFF or when the power is OFF). A sustained control output is used. Power Start signal Basic Operation Gate Power Reset Start signal input Control output Timing Output Set value Timing diagram Timing Sustained * Output is instantaneous when setting is 0. UP 0 Set value DOWN 0 Z mode: ON/OFF-duty adjustable flicker Power Start signal Gate Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when power comes ON or when the reset input goes OFF. Basic Operation Power Reset Control output Start signal ** input Cycle time UP Timing ON duty (%) ON duty setting (%) ON time Timing diagram Timing (cycle time) 0 Timing (cycle time) Timing ON duty (%) Output Cycle time ON duty setting (%) ON time DOWN 0 * Normal output operation will not be possible if the set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. Z Mode Output quantity can be adjusted by changing the cycle time set in the adjustment level to 1 and by changing the ON duty (%) set value. The set value shows the ON duty (%) and can be set to a value between 0 and 100 (%). When the cycle time is 0, the output will always be OFF. When the cycle time is not 0 and when ON duty has been set to 0 (%), the output will always be OFF. When ON duty has been set to 100 (%), the output will always be ON. 24 H5CX-A/-L Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display e1 Not lit e2 e2 Error Output status Correction method Set value after reset CPU OFF Either press the reset key or reset the No change power supply. Not lit Memory error (RAM) OFF Reset the power supply. No change sum Memory error (EEP) (See note) OFF Reset to the factory settings using the reset key. 0 Note: This includes times when the life of the EEPROM has expired. 25 H5CX-A/-L Operating Procedures (Twin Timer Function) Switching from Timer to Twin Timer The H5CX is factory-set for timer operation. To switch to twin timer operation, use the procedure given below. For details, refer to page 32. Power ON Timer/twin timer selection mode Timer/ twin timer selection Run mode 1 + Hold down for 1 s min. (See note.) Note: The key must be pressed before the 1 key. Switch from timer operation ( ) to twin timer ( ) operation using the keys. Settings for Basic Functions Settings for basic functions can be performed with just the DIP switch. Be sure to set pin 1 to ON when using the DIP switch. 1 2 3 4 5 6 7 8 ON OFF Item 1 2 DIP switch settings enable/ disable OFF Disabled ON Enabled OFF time range Refer to the table on the right. 3 4 ON time range Refer to the table on the right. 6 ON/OFF start mode Flicker OFF start 7 Timer mode UP DOWN 8 Input signal width 20 ms 1 ms Pin 2 OFF time range OFF 0.01 s to 99.99 s ON OFF 0.1 s to 999.9 s OFF ON 1 s to 9999 s ON ON 0 min 01 s to 99 min 59 s 5 Flicker ON start Pin 3 OFF Pin 4 OFF Pin 5 ON time range OFF 0.01 s to 99.99 s ON OFF 0.1 s to 999.9 s OFF ON 1 s to 9999 s ON ON 0 min 01 s to 99 min 59 s Note: All the pins are factory-set to OFF. Easy Confirmation of Switch Settings Using Indicators The ON/OFF status of the DIP switch pins can be confirmed using the front display. For details, refer to page 31. Note 1. Be sure to set pin 1 of the DIP switch to ON. If it is set to OFF, the DIP switch settings will not be enabled. 2. Changes to DIP switch settings are enabled when the power is turned ON. (Perform DIP switch settings while the power is OFF.) 3. There is no DIP switch on the H5CX-L8@. For details on the setting methods, refer to page 27. 4. When using time ranges that cannot be set with the DIP switch, all of the settings have to be made using the operation keys. For details on the setting methods, refer to page 27. Detailed Settings After making DIP switch settings for basic functions, detailed settings (see note) can be added using the operation keys. For details, refer to page 27. Note: NPN/PNP input mode, display color, key protect level. 26 H5CX-A/-L Settings for Advanced Functions Settings that cannot be performed with the DIP switch are performed with the operation keys. Power ON Run mode For details on operations in run mode, refer to page 29. Note 1. If the mode is switched to the function setting mode during operation, operation will continue. 2. Changes made to settings in function setting mode are enabled for the first time when the mode is changed to run mode. Also, when settings are changed, the timer is reset (time initialized and output turned OFF). (See note 1.) (See note 2.) The characters displayed in reverse video are the initial values. 3 s min. 3 s min. OFF time range When performing settings with operation keys only, set pin1 of the DIP switch to OFF (factory setting). If pin 1 of the DIP switch is set to ON, the setting items indicated by will not be displayed. Set the OFF time range using the s s keys. ...... s h s h s For details, refer to Time Range List below. ON time range Set the ON timer range using the s s keys. ...... s For details, refer to Time Range List below. Timer mode Set the timer mode using the keys. Function setting mode (Elapsed (Remaining time) time) ON/OFF start mode Set the twin timer output mode using the keys. (Flicker OFF (Flicker ON start) start) Time Range List Display Input signal width Set the input signal width using the (20 ms) keys. Set Value 0.01 s to 99.99 s (default setting) 0.1 s to 999.9 s (1 ms) 1 s to 9999 s NPN/PNP input mode Set the NPN/PNP input mode using the keys. (NPN input) (PNP input) Only displayed for H5CX-A@ and H5CX-A11@ models. 0 min 01 s to 99 min 59 s 0.1 min to 999.9 min 1 min to 9999 min Display color Set the display color using the keys. 0 h 01 min to 99 h 59 min (Red) (Green) (Red-green) (Green-red) Displayed for terminal-block models (H5CX-A@) only. Key protect level Set the key protect level using the (KP-1) (KP-2) (KP-3) keys. (KP-4) (KP-5) 0.1 h to 999.9 h 1 h to 9999 h 0.001 s to 9.999 s 27 H5CX-A/-L Explanation of Functions OFF Time Range (oftr) (Setting possible using DIP switch.) Input Signal Width (iflt) (Setting possible using DIP switch.) Set the time range for the OFF time in the range 0.000 s to 9,999 h. Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s), and -- min -- s (99 min 59 s), however, can be made with the DIP switch. Use the operation keys if another type of setting is required. Set the minimum signal input width (20 ms or 1 ms) for signal, reset, and gate inputs. The same setting is used for all external inputs (signal, reset, and gate inputs). If contacts are used for the input signal, set the input signal width to 20 ms. Processing to eliminate chattering is performed for this setting. ON Time Range (ontr) (Setting possible using DIP switch.) NPN/PNP Input Mode (imod) Set the time range for the ON time in the range 0.001 s to 9,999 h. Only settings of type --.-- s (99.99 s), ---.- s (999.9 s), ---- s (9,999 s), and -- min -- s (99 min 59 s), however, can be made with the DIP switch. Use the operation keys if another type of setting is required. Select either NPN input (no-voltage input) or PNP input (voltage input) as the input format. The same setting is used for all external inputs. For details on input connections, refer to Input Connections on page 9. Timer Mode (timm) (Setting possible using DIP switch.) Display Color (colr) Set either UP (incremental) or DOWN (decremental) timer mode. In UP mode, the elapsed time is displayed, and in DOWN mode, the remaining time is displayed. Set the color used for the present value. ON/OFF Start Mode (totm) (Setting possible using DIP switch.) red Red (fixed) grn Green (fixed) r-g Red Green g-r Green Red Output OFF Set the output mode. Set either flicker OFF start or flicker ON start. (For details on output mode operation, refer to Timing Charts on page 30.) Output ON Key Protect Level (kypt) Set the key protect level. When the key-protect switch is set to ON, it is possible to prevent setting errors by prohibiting the use of certain operation keys by specifying the key protect level (KP-1 to KP-5). The key protect indicator is lit while the key-protect switch is set to ON. (See note) OFF ON Note: Factory-set to OFF Key protect indicator Level Meaning Details Changing mode (See note.) Switching display during operation Reset key Up/down key KP-1 (default setting) No Yes Yes Yes KP-2 No Yes No Yes KP-3 No Yes Yes No KP-4 No Yes No No KP-5 No No No No Note: Changing mode to timer/twin timer selection mode ( MODE + 1 1 s min.) or function setting mode ( MODE 3 s min.). 28 H5CX-A/-L Operation in Run Mode Present value Set the digits for the OFF set time using the corresponding keys. Set the digits for the ON set time using the corresponding keys. OFF set time Present value ON set time Present Value and OFF Set Time The present value is displayed in the main display and the OFF set time is displayed in the sub-display. "SET1" lights at the same time. Present Value and ON Set Time The present value is displayed in the main display and the ON set time is displayed in the sub-display. "SET2" lights at the same time. 29 H5CX-A/-L Timing Charts Twin Timer Operation The gate input is not included in the H5CX-L8@ models. Output mode toff: Flicker OFF start Sustained Output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (OFF at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Reset Start signal ** input Control output OFF time Timing ON Timing OFF Timing ON Output UP ON time Timing diagram Timing OFF * Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. 0 OFF time DOWN ON time 0 Output mode ton: Flicker ON start Sustained Output Timing starts when the start signal goes ON. The status of the control output is reversed when time is up (ON at start). While the start signal is ON, the timer starts when the power comes ON or when the reset input goes OFF. Power Start signal Basic Operation Gate Power Reset Start signal ** input Control output OFF time Timing ON Timing OFF Timing ON Timing OFF Output UP Timing diagram ON time * Normal output operation will not be possible if the ON/OFF set time is too short. Set the value to at least 100 ms (contact output type). ** Start signal input is disabled during timing. 0 OFF time DOWN ON time 0 Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display e1 Not lit e2 e2 Error Output status Correction method Set value after reset CPU OFF Either press the reset key or reset the No change power supply. Not lit Memory error (RAM) OFF Reset the power supply. No change sum Memory error (EEP) (See note) OFF Reset to the factory settings using the reset key. 0 Note: This includes times when the life of the EEPROM has expired. 30 H5CX-A/-L Operation in Timer/Twin Timer Selection Mode Select whether the H5CX is used as a timer or a twin timer in timer/twin timer selection mode. The H5CX is also equipped with a DIP switch monitor function, a convenient function that enables the settings of the DIP switch pins to be confirmed using the front display. Power ON Run Mode 1 To change the mode to timer/twin timer selection mode, hold 1 key for 1 s min. with the MODE key held down. down the The MODE key must be pressed before the 1 key. If the 1 key is pressed first, the mode will not change. + Timer/Twin Timer Selection Mode 1 1 s min. Timer/Twin timer selection Select either timer operation or twin timer operation using the keys. (Timer) (Twin timer) Note: The H5CX is factory-set for timer operation. DIP switch monitor Confirm the status of DIP switch pins 1 to 8 using the keys. Note 1. This display is not supported with H5CX-L8@. 2. This display is only possible when DIP switch pin 1 (DIP switch settings enable/disable) is set to ON (enable). Example 1 2 3 4 5 6 7 8 ON OFF Indicates that DIP switch pin 8 is ON. Indicates that DIP switch pin 7 is OFF. Indicates that DIP switch pin 6 is ON. Indicates that DIP switch pin 5 is OFF. Indicates that DIP switch pin 4 is ON. Indicates that DIP switch pin 3 is OFF. Indicates that DIP switch pin 2 is ON. Indicates that DIP switch pin 1 is ON. Note 1. When the mode is changed to timer/twin timer selection mode, the present value is reset and output turns OFF. Timing operation is not performed in timer/twin timer selection mode. 2. Setting changes made in timer/twin timer selection mode are enabled when the mode is changed to run mode. If settings are changed, the HC5X is automatically reset (present value initialized, output turned OFF). 31 H5CX-A/-L Additional Information Using the Operation Keys Timer Operation Operation stopped Power ON Can be in operation 1 + 1 s min. 3 s min. Timer/twin timer selection mode Run mode 1 + 1 s min. Timer (Except for Z mode) Function setting mode 3 s min. Time range Timer/twin timer selection PV/SV DIP switch monitor Timer mode Timer (Z mode) Output mode PV/ON duty ratio Output time PV/cycle time Input signal width NPN/PNP input mode Display color Key protect level Twin Timer Operation Operation stopped Power ON + 1 3 s min. 1 s min. Timer/twin timer selection mode Run mode + DIP switch monitor Function setting mode 1 3 s min. 1 s min. Timer/twin timer selection Can be in operation PV/OFF set time OFF time range PV/ON set time ON time range Timer mode Twin timer output mode Input signal width NPN/PNP input mode Display color Key protect level Note 1. All setting changes are performed using the and keys. 2. The above flowcharts outline the procedure for all models. For details on specific models, refer to page 19 (timer operation) or page 27 (twin timer operation). 32 H5CX-A/-L List of Settings Fill in your set values in the set value column of the following tables and utilize the tables for quick reference. Timer/Twin Timer Selection Mode Parameter name Parameter Setting range Default value Unit Timer/Twin Tim- func er selection tim/twin tim --- DIP switch moni- dip tor on/off off --- Set value Settings for Timer Operation Run Mode when Output Mode Is Not Z Parameter name Present value, set value Parameter Set value Setting range --- Present value Default value Unit 0.00 to 99.99 (Time range: --,--s) 0.00 s --- 0.0 to 999.9 (Time range: ---,-s) 0.0 s --- 0 to 9999 (Time range: ----s) 0 s --- 0:00 to 99:59 (Time range: --min--s) 0:00 min; s --- 0.0 to 999.9 (Time range: ---,-min) 0.0 min --- 0 to 9999 (Time range: ----min) 0 min --- 0:00 to 99:59 (Time range: --h--min) 0:00 h; min --- 0.0 to 999.9 (Time range: ---,-h) 0.0 h --- 0 to 9999 (Time range: ----h) 0 h --- 0.000 to 9.999 (Time range: -,---s) 0.000 s --- Same as set value Same as left Same as left Set value Run Mode when Output Mode = Z Parameter name Present value, ON duty ratio Present value, cycle time Cycle time Parameter Setting range Default value Unit --- 0.00 to 99.99 (Time range: --,--s) 0.00 s --- 0.0 to 999.9 (Time range: ---,-s) 0.0 s --- 0 to 9999 (Time range: ----s) 0 s --- 0:00 to 99:59 (Time range: --min--s) 0:00 min; s --- 0.0 to 999.9 (Time range: ---,-min) 0.0 min --- 0 to 9999 (Time range: ----min) 0 min --- 0:00 to 99:59 (Time range: --h--min) 0:00 h; min --- 0.0 to 999.9 (Time range: ---,-h) 0.0 h --- 0 to 9999 (Time range: ----h) 0 h --- 0.000 to 9.999 (Time range: -,---s) 0.000 s ON duty ratio --- 0 to 100 0 % Present value --- Same as cycle time above Same as left Same as left Present value --- Same as cycle time above Same as left Same as left Set value Function Setting Mode Parameter name Parameter Setting range Default value Unit Time range timr --.--s/---.-s/----s/--min--s/---.-min/----min/-h--min/---.-h/----h/-.---s --.--s Timer mode timm up/down up --- Output mode outm a/a-1/a-2/a-3/b/b-1/d/e/f/= a --- Output time otim hold/0.01 to 99.99 hold s Input signal width iflt 20ms/1ms 20ms --- NPN/PNP input mode imod npn/pnp npn --- Display color colr red/org/r-o/o-r red --- Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 kp-1 --- Set value --- 33 H5CX-A/-L Settings for Twin Timer Operation Run Mode Parameter name Present value, OFF set time Present value, ON set time OFF set time Parameter Setting range Default value Unit --- 0.00 to 99.99 (Time range: --,--s) --- 0.0 to 999.9 (Time range: ---,-s) 0.0 s --- 0 to 9999 (Time range: ----s) 0 s --- 0:00 to 99:59 (Time range: --min--s) 0:00 min; s --- 0.0 to 999.9 (Time range: ---,-min) 0.0 min --- 0 to 9999 (Time range: ----min) 0 min --- 0:00 to 99:59 (Time range: --h--min) 0:00 h; min --- 0.0 to 999.9 (Time range: ---,-h) 0.0 h --- 0 to 9999 (Time range: ----h) 0 h s Set value s 0.00 --- 0.000 to 9.999 (Time range: -,---s) 0.000 Present value --- Same as OFF set time above Same as left Same as left ON set time --- Same as OFF set time above Same as left Same as left Present value --- Same as OFF set time above Same as left Same as left Function Setting Mode Parameter name Parameter Setting range Default value Unit OFF time range oftr --.--s/---.-s/----s/--min--s/---.-min/----min/ --h--min/---.-h/----h/-.---s --.--s --- ON time range ontr --.--s/---.-s/----s/--min--s/---.-min/----min/ --h--min/---.-h/----h/-.---s --.--s --- Timer mode timm up/down up --- ON/OFF start mode totm toff/ton toff --- Input signal width iflt 20ms/1ms 20ms --- NPN/PNP input mode imod npn/pnp npn --- Display color colr red/grn/r-g/g-r red --- Key protect level kypt kp-1/kp-2/kp-3/kp-4/kp-5 kp-1 --- Set value 34 2-stage Digital Timer H5CX-B DIN 48 x 48-mm Digital Timer with 6-digit Display and Forecast Output * Times the daily operating hours of machinery and tools, predicting and notifying when maintenance is required. * The 2-stage settings and forecast output are ideal for maintenance applications. * All settings can be performed easily with a DIP switch. * PNP/NPN switchable DC-voltage input. Contents Model Number Structure ............................................................. 36 Ordering Information.................................................................... 36 Specifications .............................................................................. 37 Connections................................................................................. 39 Nomenclature .............................................................................. 42 Dimensions.................................................................................. 43 Operating Procedures ................................................................. 44 35 H5CX-B Model Number Structure Model Number Legend H5CX-BWSD 1 2 3 4 1. Type classifier B: 6-digit display type 2. Stage setting W: 2-stage setting 3. Output type S: Transistor output 4. Supply voltage D: 12 to 24 VDC Ordering Information List of Models Output type Supply voltage 6-digit display Screw terminals Transistor 12 to 24 VDC H5CX-BWSD Accessories (Order Separately) Name Flush Mounting Adapter (See note.) Models Y92F-30 Waterproof Packing (See note.) Y92S-29 Hard Cover Y92A-48 Soft Cover Y92A-48F1 Note: Supplied with H5CX-BWSD. 36 H5CX-B Specifications Ratings Item H5CX-BWSD Classification Digital timer Rated supply voltage 12 to 24 VDC (permissible ripple: 20% (p-p) max.) Operating voltage range 90% to 110% rated supply voltage Power consumption (See note 1.) Approx. 2.3 W at 12 VDC Mounting method Flush mounting External connections Screw terminals Terminal screw tightening torque 0.5 N*m max. Display (See note 2.) 7-segment, negative transmissive LCD; Present value: 9-mm-high characters, red Set value: 6-mm-high characters, green Digits 6 digits Time ranges 9999.99 s (0.01-s unit), 99 h 59 min 59 s (1-s unit), 99999.9 min (0.1-min unit), 99999.9 h (0.1-h unit) Timer mode Elapsed time (Up) Input signals Signal, reset, gate Input method No-voltage input/voltage input (switchable) No-voltage Input ON impedance: 1 k max. (Leakage current: 5 to 20 mA when 0 ) ON residual voltage: 3 V max. OFF impedance: 100 k min. Voltage Input High (logic) level: 4.5 to 30 VDC Low (logic) level: 0 to 2 VDC (Input resistance: approx. 4.7 k) Signal, reset, gate Minimum input signal width: 1 or 20 ms (selectable, same for all input) Reset system Power resets (only for A mode), external and manual reset Power reset Minimum power-opening time: 0.5 s (except for F-1 mode) Reset voltage 10% max. of rated supply voltage Sensor waiting time 250 ms max. (Control output is turned OFF and no input is accepted during sensor waiting time.) Output modes A, F-1 Control output Transistor output: NPN open collector, 100 mA at 30 VDC max. residual voltage: 1.5 VDC max. (Approx. 1 V) Leakage current: 0.1 mA max. Output category according to EN60947-5-2 (DC-13; 30 V 100 mA) Key protection Yes Memory backup EEPROM (overwrites: 100,000 times min.) that can store data for 10 years min. Ambient temperature Operating: Storage: Ambient humidity 25% to 85% -10 to 55C (-10 to 50C if timers are mounted side by side) (with no icing or condensation) -25 to 65C (with no icing or condensation) Case color Black (N1.5) Attachments Waterproof packing, flush mounting adapter, unit label Note 1. Inrush current will flow for a short time when the power supply is turned ON. Refer to Inrush Current (Reference Values) on page 38. 2. The display is lit only when the power is ON. 37 H5CX-B Characteristics Item H5CX-BWSD Accuracy of operating time Power-ON start: 0.02% 0.05 s max. Rated against set value and setting error (including Signal start (minimum pulse width of 20 ms): 0.01% 0.03 s max. Rated against set value temperature and voltage inSignal start (minimum pulse width of 1 ms): 0.01% 3 ms max. fluences) (See note 1.) If the set value is within the sensor waiting time at startup the control output of the H5CX will not turn ON until the sensor waiting time passes. Insulation resistance 100 M min. (at 500 VDC) between current-carrying terminal and exposed non-current-carrying metal parts Dielectric strength 2,000 VAC, 50/60 Hz for 1 min between current-carrying metal parts and non-current-carrying metal parts 1,000 VAC, 50/60 Hz for 1 min between control output, power supply, and input circuit Impulse withstand voltage 1.0 kV (between power terminals) 1.5 kV (between current-carrying terminal and exposed non-current-carrying metal parts) Noise immunity 480 V (between power terminals) and 600 V (between input terminals), square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Static immunity Destruction: 15 kV Malfunction: 8 kV Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm single amplitude each in three directions, 2 hours each Malfunction: 10 to 55 Hz with 0.35-mm single amplitude each in three directions, 10 min each Shock resistance Destruction: 294 m/s2 each in three directions Malfunction: 196 m/s2 each in three directions Approved safety standards (See note 2.) UL508/Listing, UL50 Type 4X for indoor use (enclosure rating), CSA C22.2 No. 14, conforms to EN61812-1 (Pollution degree 2/overvoltage category III) Conforms to VDE0106/P100 (finger protection). EMC (EMI) Emission Enclosure: (EMS) Immunity ESD: Immunity RF-interference: EN61812-1 EN55011 Group 1 class A EN61812-1 EN61000-4-2: 6 kV contact discharge (level 2) 8 kV air discharge (level 3) EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3); 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3) Immunity Conducted Disturbance: Immunity Burst: EN61000-4-6: EN61000-4-4: Immunity Surge: EN61000-4-5: 10 V (0.15 to 80 MHz) (level 3) 2 kV power-line (level 3); 1 kV I/O signal-line (level 4) 1 kV line to lines (power and output lines) (level 3); 2 kV line to ground (power and output lines) (level 3) Degree of protection Panel surface: IP66 and NEMA4 (indoors), and UL Type 4X (indoors) (See note 2.) Weight Approx. 140 g Note 1. The values are based on the set value. 2. The Y92S-29 Waterproof Packing and Y92F-30 Flush Mounting Adapter are necessary to ensure IP66, NEMA4, and UL Type 4X waterproofing between the H5CX and installation panel. Inrush Current (Reference Values) Voltage Applied voltage 12 to 24 VDC 26.4 VDC Inrush current (peak value) 6A Time 1.2 ms 38 H5CX-B Connections Block Diagram Power supply circuit Output circuit (Basic insulation) Display circuit Internal control circuit Input circuit Key switch circuit I/O Functions Inputs Start signal Starts timing. Reset Resets present value. (The present value returns to 0.) Timing stops and control output turns OFF while reset input is ON. Reset indicator is lit while reset input is ON. Gate Outputs Forecast value setting Absolute value setting Inhibits timer operation. Control output (OUT2) Turns ON when the present value reaches the set value. Forecast output (OUT1) Turns ON when the present value reaches the forecast value. The forecast value = set value - forecast set value Control output 2 (OUT2) Turns ON when the present value reaches set value 2. Control output 1 (OUT1) Turns ON when the present value reaches set value 1. 39 H5CX-B Reset Signal Gate Reset Terminal Arrangement 7 8 9 10 Input use 0 V 6 Unused 11 1 12 2 3 13 4 OUT1 5 OUT2 (-) (+) Note 1. Do not connect unused terminals as relay terminals. 2. The power supply and input circuit are not isolated. 3. Terminals 1 and 6 are connected internally. 4. Terminals 7 and 10 have the same reset function. The same function will be performed whichever terminal is connected. Terminals 7 and 10 are not connected internally, however, so do not use them for cross-over wiring. 5. Recommended lead wires: AWG18 to AWG24 (cross-sectional area: 0.205 to 0.823 mm2), single line or twisted-pair cable, made of copper or aluminum. Input Circuits Signal, Reset, and Gate Input No-voltage Input (NPN Inputs) Voltage Inputs (PNP Inputs) Approx. 4.7 k +14 V IN 1 k IN Internal circuit Internal circuit 40 H5CX-B Input Connections The inputs of the H5CX-B are no-voltage (short-circuit or open) inputs or voltage inputs. No-voltage Inputs (NPN Inputs) Contact Input Open Collector Voltage Output (Connection to NPN open collector output sensor) (Connection to a voltage output sensor) PLC or sensor DC Two-wire Sensor Operate with transistor ON Operate with transistor ON Operate with relay ON Reset input Gate input Signal input Input 0V Reset input Gate input Reset input Reset input Signal input 0V Input Gate input Reset input Signal input Input 0V Reset input Gate input Reset input Signal input Input 0V Reset input Sensor Operate with transistor ON Applicable Two-wire Sensor Leakage current: Switching capacity: Residual voltage: Operating voltage: 1.5 mA max. 5 mA min. 3.0 VDC max. 10 VDC No-voltage Input Signal Levels No-contact input Short-circuit level Transistor ON Residual voltage: 3 V max. Impedance when ON: 1 k max. (the leakage current is about 12 mA when the impedance is 0 ) Open level Transistor OFF Impedance when OFF: 100 k min. Contact input Use contact which can adequately switch 5 mA at 10 V Note: The DC voltage must be 30 VDC max. Voltage Inputs (PNP Inputs) No-contact Input (NPN Transistor) No-contact Input (PNP Transistor) (Connection to NPN open collector output sensor) (Connection to PNP open collector output sensor) Contact Input Operate with transistor ON Operate with transistor OFF Reset input Gate input Reset input Signal input 0V Input Reset input Gate input Input Reset input 0V Reset input Gate input Signal input Input Reset input 0V Signal input Sensor Sensor Operate with relay ON Voltage Input Signal Levels High level (Input ON): Low level (Input OFF): Input resistance: 4.5 to 30 VDC 0 to 2 VDC Approx. 4.7 k Note: The DC voltage must be 30 VDC max. 41 H5CX-B Nomenclature Operation Key Indicator Reset Indicator (orange) Lit when the reset input or Reset Key is ON. Key Protection Indicator (orange) Lit when the Key-protect Switch is ON. Control Output Indicator (orange) Forecast value setting: Forecast output ON: 1 is lit Control output ON: 2 is lit Absolute value setting: Control output 1 ON: 1 is lit Control output 2 ON: 2 is lit Mode Key (Changes setting items) Reset Key (Resets present value and output) Up Keys 1 to 6 Sixth digit First digit Front View Present Value (red) Character height: 9 mm If the time range is 0.0 min or 0.0 h, the decimal point flashes to indicate timing operation. Set Value (green) Character height: 6 mm Switches Key-protect Switch When the Key-protect Switch is ON, key operations are prohibited according to the settings for DIP switch pins 6 to 8, thus preventing setting errors. The Key-protect Switch can be turned ON and OFF while the power is ON. The Key Protection Indicator is lit orange when the Key-protect Switch is ON. (Default setting) OFF ON Set Value 1, 2 Display (green) DIP Switch Refer to DIP Switch Settings on page 45 for details on setting the DIP switch. 1 2 3 4 5 6 7 8 ON OFF (Default setting) Unit Label The unit label is included with the Unit. Affix the unit label in the position shown in the following diagram to match the time range to be used. Align the right edge of the label with the right edge of the display window. Unit label 42 H5CX-B Dimensions Note: All units are in millimeters unless otherwise indicated. Dimensions without Flush Mounting Adapter H5CX-BWSD (Flush Mounting Models) Panel Cutouts 6 48x48 Panel cutouts areas shown below. (according to DIN43700). 64 60 min. 44.8x44.8 45 +0.6 -0 45 +0.6 -0 Note: M3.5 terminal screw (effective length: 6 mm) 60 min. 15 min. Dimensions with Flush Mounting Adapter H5CX-BWSD (Provided with Adapter and Waterproof Packing) Y92S-29 (provided) Waterproof Packing 58 Panel Y92F-30 (provided) Flush Mounting Adapter Note 1. The mounting panel thickness should be 1 to 5 mm. 2. To allow easier operability, it is recommended that Adapters are mounted so that the gap between sides with hooks is at least 15 mm. 3. It is possible to mount timers side by side, but only in the direction without the hooks. (51) n side by side mounting 48 7.5 62.5 A A = (48n - 2.5) +1 0 With Y92A-48F1 attached. A = {48n-2.5 + (n-1) x 4} +1 0 With Y92A-48 attached. A = (51n-5.5) +1 0 Accessories (Order Separately) Hard Cover Y92A-48 Soft Cover Y92A-48F1 Note: 1. Depending on the operating environment, the condition of resin products may deteriorate, and may shrink or become harder. Therefore, it is recommended that resin products are replaced regularly. 2. The H5CX's panel surface is water-resistive (conforming to IP66) and so even if drops of water penetrate the gaps between the keys, there will be no adverse effect on internal circuits. If, however, there is a possibility of oil being present on the operator's hands, use the Soft Cover. The Soft Cover ensures protection equivalent to IP54F against oil. Do not, however, use the H5CX in locations where it would come in direct contact with oil. Flush Mounting Adapter (provided with H5CX-BWSD) Y92F-30 Waterproof Packing (provided with H5CX-BWSD) Y92S-29 Note: Order the Flush Mounting Adapter separately if it is lost or damaged. Note: Use Waterproof Packing to provide a level of water protection that complies with NEMA4, UL Type 4X, or IP66 standards. Order the Waterproof Packing separately if it is lost or damaged. Depending on the operating environment, the Waterproof Packing may deteriorate, contract, or harden and so regular replacement is recommended. 43 H5CX-B Operating Procedures Setting Set Values Set values can be set either as offset values (forecast value setting) or absolute values. Set values are factory-set to forecast value setting. Forecast Value Setting Example: F-1 Mode Present value Turn ON the power while pressing the Key and 4 Key. Set value Timing stopped Timing possible Forecast set value Forecast value 0 Setting Method Selection Mode Change the setting method using Keys 1 to 6. Forecast output (OUT1) Control output (OUT 2) (Forecast value setting) (Absolute value setting) Turn ON the power again. Run Mode 1. Move to Setting Method Selection Mode by turning ON the power while pressing both the Key and 4 Key at the same time. 2. Select forecast value setting ( ) or absolute value setting ( ) using the Keys. 3. When the power is turned ON again, the Timer will start with the selected setting method. Note 1: In Setting Method Selection Mode, outputs are OFF and the timer is stopped. 2: When the setting method is changed, the set values and present value are reset to 0, and outputs are OFF. * OUT1 (forecast output) turns ON when the present value reaches the forecast value. The forecast value = set value - forecast set value The forecast set value is used to set the deviation for the set value. * OUT2 (control output) turns ON when the present value reaches the set value. * If the forecast set value set value, OUT1 (forecast output) will turn ON as soon as timing starts. Absolute Value Setting Example: F-1 Mode Present value Set value 2 Set value 1 0 Control output 1 (OUT1) Control output 2 (OUT 2) * OUT1 (control output 1) turns ON when the present value reaches set value 1. * OUT2 (control output 2) turns ON when the present value reaches set value 2. 44 H5CX-B DIP Switch Settings All functions are set using the DIP switch. Item 1 OFF ON Time range Refer to the table on the right. 3 Output mode F-1 mode A mode 4 Input signal width 20 ms 1 ms 5 NPN/PNP input mode NPN PNP 6 Reset Key protection Disabled Enabled 7 Up Key protection Disabled Enabled 8 Mode Key protection Disabled Enabled Pin 1 2 Pin 2 Time range OFF OFF 0.1 h to 99999.9 h ON OFF 0.01 s to 9999.99 s OFF ON 0 h 00 min 01 s to 99 h 59 min 59 s ON ON 0.1 min to 99999.9 min 1 2 3 4 5 6 7 8 ON OFF (Default setting) Note 1: All the pins are factory-set to OFF. 2: DIP switch settings are effective when the power is turned ON again. (Set the DIP switch before installation and powerup.) 3: The characters displayed in reverse video are the default settings. Operation in Run Mode Set each digit for the set value using the corresponding Keys. Forecast Value Setting Present value Set value Present value Each time the Key is pressed, the sub-display will switch between the set value ("SET" is lit) and the forecast set value ("1" is lit). Forecast set value Absolute Value Setting Present value Set value 1 Present value Each time the Key is pressed, the sub-display will switch between set value 1 ("SET 1" is lit) and set value 2 ("SET 2" is lit). Set value 2 45 H5CX-B Timing Charts A Mode: Signal ON delay (Timer resets when power comes ON.) * Timing starts when the start signal turns ON. * While the start signal is ON, the timer starts when the power turns ON or when the reset input turns OFF. * A sustained control output is used. * Timing stops when the time is up. Power Start signal Gate Basic Operation Timing diagram Reset Power 999999 Set value (SV 2) Forecast value (SV 1) 0 Start signal input** Timing Forecast output (Control output 1) OUT1 Control output (Control output 2) OUT2 OUT1 OUT2 The names in parentheses are used for the absolute value setting. The names in parentheses are used for the absolute value setting. * Output is instantaneous when the set value is 0. ** Start signal input is disabled during timing. F-1 mode: Cumulative (Timer does not reset when power comes ON.) * Start signal enables timing (timing is stopped when the start signal is OFF or when the power is OFF). * A sustained control output is used. * Timing continues even after the time is up. Power Start signal Basic Operation Gate Power Timing diagram Reset 999999 Set value (SV 2) Start signal input Forecast value (SV 1) Forecast output (Control output 1) OUT1 Control output (Control output 2) OUT2 0 OUT1 OUT2 The names in parentheses are used for the absolute value setting. * Timing Timing Sustained The names in parentheses are used for the absolute value setting. Output is instantaneous when the set value is 0. Note: Forecast Value = Set Value - Forecast Set Value The forecast set value is used to set the deviation for the set value. Self-diagnostic Function The following displays will appear if an error occurs. Main display Sub-display e1 Not lit e2 e2 Error Output status Correction method Set value after reset CPU OFF Either press the reset key or reset the No change power supply. Not lit Memory error (RAM) OFF Reset the power supply. No change sum Memory error (EEP) (See note) OFF Reset to the factory settings using the reset key. 0 Note: This includes times when the life of the EEPROM has expired. 46 H5CX-B Safety Precautions (Common) Refer to Safety Precautions for All Timers. Note: The following precautions are common for all H5CX models. CAUTION Loose screws may occasionally result in fire or malfunction. Tighten the terminal screws securely. The recommended tightening torque is 0.5 N*m. There may occasionally be a risk of explosion. Do not use the product where flammable or combustion gases are present. This may occasionally cause electric shock, fire or malfunction. Never disassemble, repair or modify the product. X2/b T T/a X1/a X1 X2 Precautions for Safe Use The following precautions must be observed to ensure safety. Operating and Storage Conditions * Do not use in locations affected by excessive vibration or shock, or in locations subject to exposure to water or oil. * Do not use the product in locations subject to dust, corrosive gases, or direct sunlight. * Separate the input signal devices, input signal cables, and the product from the source of noise or high-tension cables producing noise. * Separate the product from the source of static electricity when using the product in an environment where a large amount of static electricity is produced (e.g., forming compounds, powders, or fluid materials being transported by pipe). * Organic solvents (such as paint thinner), as well as very acidic or basic solutions might damage the outer casing of the H5CX. * Use the product within the ratings specified for temperature and humidity. * Do not use the product in locations where condensation may occur due to high humidity or where temperature changes are severe. * Store at the specified temperature. If the H5CX has been stored at a temperature of less than -10C, allow the H5CX to stand at room temperature for at least 3 hours before use. X Auxiliary relay (e.g., MY Relay) * When the product is operated with no-voltage input (NPN input), approximately 14 V is output from the input terminals, so connect a diode if the external power supply is less than 14 V. This may occasionally cause electric shock, fire or malfunction. Do not allow metal fragments or lead wire scraps to fall inside this product. If both the power supply for the input device and that for the timer are not insulated, unwanted current from the AC power supply may occasionally burn out or damage the internal parts. Always use an insulated power supply for the timer. X1/a Sensor 0V Input * Install a switch or circuit-breaker that allows the operator to immediately turn OFF the power, and make sure it is labeled clearly. * The H5CX's panel surface is water-resistive (conforming to NEMA 4, UL Type 4X, and IP66). In order to prevent the internal circuit from water penetration through the space between the H5CX and operating panel, attach a waterproof packing (Y92S-29) between the H5CX and installation panel and secure the waterproof packing with the Y92F-30 Flush-mounting Adapter. 0.5 to 1 mm It is recommended that the space between the screw head and the adapter should be 0.5 to 1 mm. * Tighten the two mounting screws on the Adapter. Tighten them alternately, a little at a time, so as to keep them at an equal tightness. If the panel screws are tightened unequally, water may ingress inside the panel. Usage Precautions * Make sure that the voltage applied is within the specified range, otherwise the internal elements of the counter may be damaged. * The load current must be within the rated current. * Ensure that the power is turned OFF before changing DIP switch settings. Changing DIP switch settings with the power turned ON may result in electric shock due to contact with terminals subject to high voltages. * Pay attention to terminal polarity to ensure correct wiring. * Make sure that the fluctuation of the supply voltage is within the permissible range. * Apply the power supply voltage through a relay or switch in such a way that the voltage reaches the rated value within 2 s. If the voltage is applied gradually, the power may not be reset or unstable output operations may result. * Leaving the H5CX with outputs ON at a high temperature for a long time may hasten the degradation of internal parts (such as electrolytic capacitors). Therefore, use the product in combination with relays and avoid leaving the product as long as more than 1 month with the output turned ON. 47 H5CX-B Precautions for Correct Use Power Supplies Turn the power ON and OFF using a relay with a rated capacity of 10 A minimum to prevent contact deterioration due to inrush current caused by turning the power ON and OFF. Be sure that the capacity of the power supply is large enough, otherwise the Timer may not start due to inrush current that may flow for an instant when the Timer is turned on. When turning the power ON and OFF, input signal reception is possible, unstable, or impossible as shown in the diagram below. Power supply ON OFF 200 ms 0 to 50 ms 5 ms 0 to 500 ms Response Delay Time When Resetting (Transistor Output) The following table shows the delay from when the reset signal is input until the output is turned OFF. (Reference value) Minimum reset signal width 0.8 to 1.2 ms 20 ms 15 to 25 ms Power Failure Backup All data is stored in the EEPROM when there is a power failure. The EEPROM can be overwritten more than 100,000 times. Operating mode Input Impossible Possible Unstable Impossible Unstable To allow for the startup time of peripheral devices (sensors, etc.), the H5CX starts timing operation between 200 ms to 250 ms after power is turned ON. For this reason, in operations where timing starts from power ON, the time display will actually start from 250 ms. If the set value is 249 ms or less, the time until output turns ON will be a fixed value between 200 and 250. (Normal operation is possible for set value of 250 ms or more.) In applications where a set value of 249 ms or less is required, use start timing with signal input. When the H5CX is used with power start in F mode or F-1 mode (i.e., accumulative operation with output on hold), there will be a timer error (approximately 100 ms each time the H5CX is turned ON) due to the characteristics of the internal circuitry. Use the H5CX with signal start if timer accuracy is required. Overwriting timing A-3, b-1, F, F-1 mode When power is turned OFF. Other mode Timer Control with Power Start Output delay time 1 ms When settings are changed. Conformance to EN/IEC Standards There is no insulation between power supply and input terminals (except for H5CX-A11/-A11S). Basic insulation between power supply and output terminals, and between input terminals and output terminals. When double insulation or reinforced insulation is required, apply double insulation or reinforced insulation defined in IEC 60664 that is suitable for the maximum operating voltage with clearances or solid insulation. Transistor Output The transistor output of the H5CX is insulated from the internal circuitry by a photocoupler, so the transistor output can be used as both NPN and PNP output. NPN Output PNP Output Load Load + + Power for load Power for load The diode connected to the collector of the output transistor is used to absorb inverted voltage that is generated when an inductive load is connected to the H5CX. Timer Inductive load + Power for load 48 H5CX-B Safety Precautions (H5CX-A/-L) CAUTION If the output relay is used beyond its life expectancy, its contacts may occasionally become fused or there may occasionally be a risk of fire. The life expectancy of the output relay varies considerably according to its usage. Use the output relay within its rated load and electrical life expectancy. Depending on the wiring, unwanted current from the AC power supply may occasionally burn out (damage) the internal parts. The H5CX-A/-L (except for H5CX-A11/-A11S) do not have transformers. Therefore, there is no insulation between the power supply and input terminals, so make sure that wiring is correct before use. For the power supply of an input device of the H5CX (except for H5CX-A11/-A11S), use an isolating transformer with the primary and secondary windings mutually isolated and the secondary winding not grounded. Correct Wiring Example H5CX Usage Precautions Do not touch the input terminals while power is supplied. The H5CX (except for H5CX-A11/-A11S) has a transformerless power supply and so touching the input terminals with power supplied may result in electric shock. Changing the Set Values When changing the set value during a timing operation, the output will turn ON if the set value is changed as follows because of the use of a constant read-in system: Elapsed time (UP) mode: Present value set value Remaining time (DOWN) mode: Elapsed time set value (The present value is set to 0.) Note: When in the remaining time mode, the amount the set value is changed is added to or subtracted from the present value. Power supply Precautions for Correct Use Input terminals Operation with a Set Value of 0 Rectifier Circuit Precautions for Safe Use Isolation transformer is required. Operation with a set value of 0 will vary with the output mode. Refer to the Timing Charts. Incorrect Wiring Example 1 Do not ground the secondary winding. If the secondary wiring is grounded, as shown in the following diagram, unwanted current may occasionally burn out or damage the internal parts. H5CX Power supply Circuit Rectifier Input terminals Incorrect Wiring Example 2 Do not simultaneously input signals from a single input contact or a transistor to two or more timers that have independent power supplies. Otherwise, the internal parts may occasionally be burnt out or damaged by unwanted current, as shown in the following diagram. H5CX Power supply Input terminals Input terminals 49 H5CX-B Safety Precautions (H5CX-B) Precautions for Safe Use Changing the Set Value When changing the set value during a timing operation, the output will turn ON if the set value is changed as follows because of the use of a constant read-in system: Forecast Value Setting When the present value the set value, OUT2 (control output) turns ON. When the present value the forecast value (forecast value = set value - forecast set value) OUT1 (forecast output) turns ON. Absolute Value Setting When the present value set value 2, OUT2 (control output 2) turns ON. When the present value set value 1, OUT1 (control output 1) turns ON. Precautions for Correct Use Operation with a Set Value of 0 When the set value is 0, the output turns ON the moment the signal is input. The reset operation turns OFF the output. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 50 Read and Understand This Catalog Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranty and Limitations of Liability WARRANTY OMRON's exclusive warranty is that the products are free from defects in materials and workmanship for a period of one year (or other period if specified) from date of sale by OMRON. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, REGARDING NON-INFRINGEMENT, MERCHANTABILITY, OR FITNESS FOR PARTICULAR PURPOSE OF THE PRODUCTS. ANY BUYER OR USER ACKNOWLEDGES THAT THE BUYER OR USER ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. OMRON DISCLAIMS ALL OTHER WARRANTIES, EXPRESS OR IMPLIED. LIMITATIONS OF LIABILITY OMRON SHALL NOT BE RESPONSIBLE FOR SPECIAL, INDIRECT, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED ON CONTRACT, WARRANTY, NEGLIGENCE, OR STRICT LIABILITY. In no event shall the responsibility of OMRON for any act exceed the individual price of the product on which liability is asserted. IN NO EVENT SHALL OMRON BE RESPONSIBLE FOR WARRANTY, REPAIR, OR OTHER CLAIMS REGARDING THE PRODUCTS UNLESS OMRON'S ANALYSIS CONFIRMS THAT THE PRODUCTS WERE PROPERLY HANDLED, STORED, INSTALLED, AND MAINTAINED AND NOT SUBJECT TO CONTAMINATION, ABUSE, MISUSE, OR INAPPROPRIATE MODIFICATION OR REPAIR. Application Considerations SUITABILITY FOR USE OMRON shall not be responsible for conformity with any standards, codes, or regulations that apply to the combination of products in the customer's application or use of the products. At the customer's request, OMRON will provide applicable third party certification documents identifying ratings and limitations of use that apply to the products. This information by itself is not sufficient for a complete determination of the suitability of the products in combination with the end product, machine, system, or other application or use. The following are some examples of applications for which particular attention must be given. This is not intended to be an exhaustive list of all possible uses of the products, nor is it intended to imply that the uses listed may be suitable for the products: * Outdoor use, uses involving potential chemical contamination or electrical interference, or conditions or uses not described in this catalog. * Nuclear energy control systems, combustion systems, railroad systems, aviation systems, medical equipment, amusement machines, vehicles, safety equipment, and installations subject to separate industry or government regulations. * Systems, machines, and equipment that could present a risk to life or property. Please know and observe all prohibitions of use applicable to the products. NEVER USE THE PRODUCTS FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCTS ARE PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. PROGRAMMABLE PRODUCTS OMRON shall not be responsible for the user's programming of a programmable product, or any consequence thereof. Disclaimers CHANGE IN SPECIFICATIONS Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change model numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the products may be changed without any notice. When in doubt, special model numbers may be assigned to fix or establish key specifications for your application on your request. Please consult with your OMRON representative at any time to confirm actual specifications of purchased products. DIMENSIONS AND WEIGHTS Dimensions and weights are nominal and are not to be used for manufacturing purposes, even when tolerances are shown. PERFORMANCE DATA Performance data given in this catalog is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of OMRON's test conditions, and the users must correlate it to actual application requirements. Actual performance is subject to the OMRON Warranty and Limitations of Liability. ERRORS AND OMISSIONS The information in this document has been carefully checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical, or proofreading errors, or omissions. 2008.11 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2008 All Right Reserved.