MIN TYP MAX
45 65
45
70
150
150
610
10 18
135
350
3.2
3.2
500
500
UNIT
ns
Amps
nC
Volts
A/µs
APT2X30/2X31D40J
Characteristic
Reverse Recovery Time, IF = 1.0A, diF/dt = -15A/µs, VR = 30V, TJ = 25°C
Reverse Recovery Time TJ = 25°C
IF = 30A, diF/dt = -240A/µs, VR = 240V TJ = 100°C
Forward Recovery Time TJ = 25°C
IF = 30A, diF/dt = 240A/µs, VR = 240V TJ = 100°C
Reverse Recovery Current TJ = 25°C
IF = 30A, diF/dt = -240A/µs, VR = 240V TJ = 100°C
Recovery Charge TJ = 25°C
IF = 30A, diF/dt = -240A/µs, VR = 240V TJ = 100°C
Forward Recovery Voltage TJ = 25°C
IF = 30A, diF/dt = 240A/µs, VR = 240V TJ = 100°C
Rate of Fall of Recovery Current TJ = 25°C
IF = 30A, diF/dt = -240A/µs, VR = 240V (See Figure 10) TJ = 100°C
DYNAMIC CHARACTERISTICS
Symbol
trr1
trr2
trr3
tfr1
tfr2
IRRM1
IRRM2
Qrr1
Qrr2
Vfr1
Vfr2
diM/dt
THERMAL AND MECHANICAL CHARACTERISTICS
Characteristic / Test Conditions
Junction-to-Case Thermal Resistance
Junction-to-Ambient Thermal Resistance
RMS Voltage (50-60 Hz Sinusoidal Waveform from Terminals to Mounting Base for 1 Min.)
Package Weight
Maximum Torque (Mounting = 8-32 or 4mm Machine and Terminals = 4mm Machine)
Symbol
RθJC
RθJA
VIsolation
WT
Torque
MIN TYP MAX
0.90
20
2500
1.03
29.2
13.6
1.5
UNIT
°C/W
Volts
oz
gm
lb•in
N•m
053-4003 Rev D
10-5 10-4 10-3 10-2 10-1 1.0 10
RECTANGULAR PULSE DURATION (SECONDS)
FIGURE 1, MAXIMUM EFFECTIVE TRANSIENT THERMAL IMPEDANCE, JUNCTION-TO-CASE vs PULSE DURATION
1.0
0.5
0.1
0.05
0.01
0.005
0.001
D=0.5
0.2
0.1
0.05
0.02
0.01
SINGLE PULSE
Note:
Duty Factor D = t1/t2
Peak TJ = PDM x ZθJC + TC
t1
t2
PDM
ZθJC, THERMAL IMPEDANCE (°C/W)