Parameter Test Conditions Min. Typ. Max. Unit
70
7
7
17
5.6
13
65
20:1
420
210
17.5
VGS = 0 ID= 100mA
VDS = 28V VGS = 0
VGS = 20V VDS = 0
ID= 10mA VDS = VGS
VDS = 10V ID= 7A
PO= 350W
VDS = 28V IDQ = 2A
f = 175MHz
VDS = 28V VGS = –5V f = 1MHz
VDS = 28V VGS = 0 f = 1MHz
VDS = 28V VGS = 0 f = 1MHz
V
mA
μA
V
S
dB
%
—
pF
pF
pF
ELECTRICAL CHARACTERISTICS (Tcase = 25°C unless otherwise stated)
Drain–Source Breakdown
Voltage
Zero Gate Voltage
Drain Current
Gate Leakage Current
Gate Threshold Voltage*
Forward Transconductance*
Common Source Power Gain
Drain Efficiency
Load Mismatch Tolerance
Input Capacitance
Output Capacitance
Reverse Transfer Capacitance
HAZARDOUS MATERIAL WARNING
The ceramic portion of the device between leads and metal flange is beryllium oxide. Beryllium oxide dust is highly
toxic and care must be taken during handling and mounting to avoid damage to this area.
THESE DEVICES MUST NEVER BE THROWN AWAY WITH GENERAL INDUSTRIAL OR DOMESTIC WASTE.
RTHj–case Thermal Resistance Junction – Case Max. 0.4°C / W
THERMAL DATA
* Pulse Test: Pulse Duration = 300 μs , Duty Cycle ≤2%
TOTAL DEVICE
PER SIDE
PER SIDE
BVDSS
IDSS
IGSS
VGS(th)
gfs
GPS
η
VSWR
Ciss
Coss
Crss