Features
■ Formerly brand
■ Extremely high speed performance
■ Blocks high voltages and currents
■ Low insertion loss
■ Two TBU® protectors in one small package
■ Very high bandwidth; GHz compatible
■ RoHS compliant*, UL Recognized
P650-U and P850-U Series TBU® High-Speed Protectors
*RoHS Directive 2002/95/EC Jan. 27, 2003 including annex and RoHS Recast 2011/65/EU June 8, 2011.
Specifi cations are subject to change without notice.
Customers should verify actual device performance in their specifi c applications.
Transient Blocking Units - TBU® Devices
Bourns® Model P650-U and P850-U products are high-speed,
unidirectional protection components, constructed using
MOSFET semiconductor technology, designed to protect against
faults caused by short circuits, AC power cross, induction and
lightning surges.
The TBU® high-speed protector, triggering as a function of the
MOSFET, blocks surges and provides an effective barrier behind
which sensitive electronics are not exposed to large voltages or
currents during surge events. The TBU® device is provided in a
surface mount DFN package and meets industry standard
requirements such as RoHS and Pb Free solder refl ow profi les.
Electrical Characteristics (Tamb = 25 °C)
The P-U Series TBU® devices are unidirectional; specifi cations are valid for input direction only. For the output direction, the TBU® device is a
resistor.
Absolute Maximum Ratings (Tamb = 25 °C)
Symbol Parameter Value Unit
Vimp Maximum protection voltage for impulse faults with rise time ≥ 1 µsec P650-Uxxx-WH
P850-Uxxx-WH
650
850 V
Vrms
Maximum protection voltage for continuous Vrms faults connected as
a series pair (refer to page 3 Test Confi guration Diagram)
P650-Uxxx-WH
P850-Uxxx-WH
300
425 V
Top Operating temperature range -40 to +85 °C
Tstg Storage temperature range -65 to +150 °C
Agency Approval
UL recognized component File # E315805.
Industry Standards
Description Model
Telcordia GR-1089
Port Type 3, 5 P650-U
Port Type 2, 4 P850-U
ITU-T K.20, K.20E, K.21, K.21E,
K.45 P850-U
Symbol Parameter Min. Typ. Max. Unit
Iop Maximum current through the device that will not cause
current blocking
P650-U180-WH
P650-U260-WH
P850-U180-WH
P850-U260-WH
180
260
180
260
mA
Itrigger Typical current for the device to go from normal operating
state to protected state
P650-U180-WH
P650-U260-WH
P850-U180-WH
P850-U260-WH
220
330
220
330
mA
Iout Maximum current through the device
P650-U180-WH
P650-U260-WH
P850-U180-WH
P850-U260-WH
360
520
360
520
mA
Rdevice Series resistance of the TBU® device P650-Uxxx-WH
P850-Uxxx-WH
6
8
7
9Ω
Rbal Line-to line series resistance difference between two TBU® devices 0.5 Ω
tblock Maximum time for the device to go from normal operating
state to protected state
P650-Uxxx-WH
P850-Uxxx-WH 1µs
Iquiescent Current through the triggered TBU® device with 50 Vdc circuit
voltage 1mA
Vreset Voltage below which the triggered TBU® device will
transition to normal operating state
P650-Uxxx-WH
P850-Uxxx-WH 11
14 V
*RoHS COMPLIANT
The P650-U & P850-U Series are
currently available, but not recom-
mended for new designs. Bourns®
TBU-DT Series is preferred.