Linear Power Supplies Data Sheet
MCD10016 Rev. 1.2, 13-Nov-09 Page 1 of 9 www.power-one.com
Power-One produces the industry’s broadest selection of
Linear power supplies with output voltages from 5 volts
through 250 volts. Rugged technology and proven design
merge to create quiet, highly-regulated, dependable
DC power.
The Linear power supplies are approved to domestic and
international regulatory standards, and are CE Marked to
the Low Voltage Directive (LVD).
RoHS compatible for all six substances
Worldwide AC Input Capabilities:
100/120/220/230/240 VAC
±0.05% Output Regulation
Low Output Ripple
UL, CSA, and TÜV Approvals
Mean Time Before Failure (MTBF) in Excess of
300,000 Hours
CE marked to Low Voltage Directive
100% Burn-In
2 Year Warranty
Overvoltage Protection (OVP) Standard on 5V
Single Outputs, Optional for other outputs
under 48V
Features
Description
OVERVOLTAGE PROTECTION OPTIONS
These optional overvoltage protection modules are offered for use with
Power-One’s Linear power supplies. Each is user adjustable from 6.4V to 34V.
OVP SELECTION GUIDE
MODEL CASE SIZE OVP MODULES REQUIRED
SINGLE B,C,N,D (1) OVP-12G
OUTPUT E,F (1) OVP-24G
DUAL AA,B,BB,CC (1) OVP-12G protects both outputs
OUTPUT E (1) OVP-24G protects both outputs
TRIPLE AA,BAA,D (1) OVP-12G protects both 12V
OUTPUT CBB, 131 through 15V outputs
DBB,DCC
PEAK N,BAA,CBB
CURRENT 131 (1) OVP-12G protects any output
MODELS not provided with built-in OVP
NOTE: Outputs with factory built-in OVP are indicated in the Voltage/Current Rating
Chart for each model. OVP is not available for 48V through 250V models.
OVP-12G
OVP-24G
Overvoltage Protection Options
MCD10016 Rev. 1.2, 13-Nov-09 Page 2 of 9 www.power-one.com
Linear Power Supplies Data Sheet
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
Case Dimensions
Type (Inches)
AA 6.50 x 4.00 x 2.10
B 4.87 x 4.00 x 2.10
BAA 10.25 x 4.00 x 2.95
BB 7.00 x 4.87 x 2.95
C 5.62 x 4.87 x 2.95
CBB 11.00 x 4.87 x 3.28
CC 9.38 x 4.87 x 3.28
CP131 11.00 x 4.87 x 3.28
D 9.00 x 4.87 x 3.28
DBB 14.25 x 4.87 x 3.38
DCC 15.00 x 4.88 x 4.55
E 14.00 x 4.87 x 3.53
F 16.75 x 4.88 x 5.00
N 7.00 x 4.87 x 3.28
Case Dimensions
Type (Millimeters)
AA 165.10 x 101.60 x 53.34
B 123.70 x 101.60 x 53.34
BAA 260.35 x 101.60 x 74.93
BB 177.80 x 123.70 x 74.93
C 142.75 x 123.70 x 74.93
CBB 279.40 x 123.70 x 83.31
CC 238.25 x 123.70 x 83.31
CP131 279.40 x 123.70 x 83.31
D 228.60 x 123.70 x 83.31
DBB 361.95 x 123.70 x 85.85
DCC 381.00 x 123.95 x 115.57
E 355.60 x 123.70 x 89.66
F 425.50 x 123.95 x 127.00
N 177.80 x 123.70 x 83.31
Nominal Max Model Input Case Additional
Vout* Amps 100 to 264 VAC Type Features & Notes
5Vout
5 1.5 HA5-1.5/OVP-AG B A
5 3 HB5-3/OVP-AG B A, C
5 6 HC5-6/OVP-AG C A, C
5 9 HN5-9/OVP-AG N A, C
5 12 HD5-12/OVP-AG D A, C
5 18 HE5-18/OVP-AG E A, C
5 25 F5-25/OVP-AG F A, C, D, H
5 35 G5-35/OVP-AG F A, C, D, H
5 50 CP197-AG F A, C, D
12 to 15Vout
12 0.9 HA15-0.9-AG B
12 1.7 HB12-1.7-AG B C
12 3.4 HC12-3.4-AG C C
12 5.1 HN12-5.1-AG N C
12 6.8 HD12-6.8-AG D C
12 10.2 HE12-10.2-AG E C
12 16 F15-15-AG F C, D, H
15* 0.9 HA15-0.9-AG B
15 1.5 HB15-1.5-AG B C
15 3 HC15-3-AG C C
15 4.5 HN15-4.5-AG N C
15 6 HD15-6-AG D C
15 9 HE15-9-AG E C
15* 15 F15-15-AG F C, D, H
24 to 28Vout
24 0.5 HA24-0.5-AG B
24 1.2 HB24-1.2-AG B C
24 2.4 HC24-2.4-AG C C
24 3.6 HN24-3.6-AG N C
24 4.8 HD24-4.8-AG D C
24 7.2 HE24-7.2-AG E C
24 12 F24-12-AG F C, D, H
28* 0.5 HA24-0.5-AG B
28 1 HB28-1-AG B C
28 2 HC28-2-AG C C
28 3 HN28-3-AG N C
28 4 HD28-4-AG D C
28 6 HE28-6-AG E C
28* 10 F24-12-AG F C, D, H
48Vout
48 0.5 HB48-0.5-AG B
48 1 HC48-1-AG C
48 3 HD48-3-AG D C
48 4 HE48-4-AG E C
* May require jumpering or potentiometer adjustment.
Unsigned output voltages are isolated and can be used as either + or - polarities.
Model numbers highlighted in yellow or shaded are not recommended for new designs.
Nominal Max Model Input Case Additional
Vout* Amps 100 to 264 VAC Type Features & Notes
5V to 15Vout
+5, –5 1.5, 1.5 HAA5-1.5/OVP-AG AA A
+5, –5 3, 3 HBB5-3/OVP-AG BB A
+5, –5 6, 6 HCC5-6/OVP-AG CC A, C
5, 12 to 15 2, 0.5 HAA512-AG AA A
5, 12 to 15 3, 1.25 HBB512-AG BB A, C
5, 12 to 15 6, 2.5 HCC512-AG CC A, C
+12, –5* 1, 0.4 HAA15-0.8-AG AA C
+12, –5* 1.7, 0.7 HBB15-1.5-AG BB C
+12, –12 0.4, 0.4 HAD12-0.4-AG B B
+12, –12 1, 1 HAA15-0.8-AG AA C
+12, –12 1.7, 1.7 HBB15-1.5-AG BB C
+12, –12 3.4, 3.4 HCC15-3-AG CC C
+12, –12* 5, 5 HDD15-5-AG E C
+12, –15* 1, 0.8 HAA15-0.8-AG AA C
+12, –15* 1.7, 1.5 HBB15-1.5-AG BB C
+12, –15* 3.4, 3 HCC15-3-AG CC C
+12, –15* 5, 5 HDD15-5-AG E C
+15, –5* 0.8, 0.4 HAA15-0.8-AG AA C
+15, –5* 1.5, 0.7 HBB15-1.5-AG BB C
+15, –12* 0.8, 1 HAA15-0.8-AG AA C
+15, –12* 1.5, 1.7 HBB15-1.5-AG BB C
+15, –12* 3, 3.4 HCC15-3-AG CC C
15, –12* 5, 5 HDD15-5-AG E C
15V to 24Vout
+15, –15 0.4, 0.4 HAD15-0.4-AG B B
+15, –15 0.8, 0.8 HAA15-0.8-AG AA C
+15, –15* 1.5, 1.5 HBB15-1.5-AG BB C
+15, –15* 3, 3 HCC15-3-AG CC C
+15, –15 5, 5 HDD15-5-AG E C
+24, –24 0.6, 0.6 HAA24-0.6-AG AA
+24, –24 1.2, 1.2 HBB24-1.2-AG BB
+24, –24 2.4, 2.4 HCC24-2.4-AG CC C
Linear Power Supplies Data Sheet
MCD10016 Rev. 1.2, 13-Nov-09 Page 3 of 9 www.power-one.com
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
Case Dimensions
Type (Inches)
AA 6.50 x 4.00 x 2.10
B 4.87 x 4.00 x 2.10
BAA 10.25 x 4.00 x 2.95
BB 7.00 x 4.87 x 2.95
C 5.62 x 4.87 x 2.95
CBB 11.00 x 4.87 x 3.28
CC 9.38 x 4.87 x 3.28
CP131 11.00 x 4.87 x 3.28
D 9.00 x 4.87 x 3.28
DBB 14.25 x 4.87 x 3.38
DCC 15.00 x 4.88 x 4.55
E 14.00 x 4.87 x 3.53
F 16.75 x 4.88 x 5.00
N 7.00 x 4.87 x 3.28
Case Dimensions
Type (Millimeters)
AA 165.10 x 101.60 x 53.34
B 123.70 x 101.60 x 53.34
BAA 260.35 x 101.60 x 74.93
BB 177.80 x 123.70 x 74.93
C 142.75 x 123.70 x 74.93
CBB 279.40 x 123.70 x 83.31
CC 238.25 x 123.70 x 83.31
CP131 279.40 x 123.70 x 83.31
D 228.60 x 123.70 x 83.31
DBB 361.95 x 123.70 x 85.85
DCC 381.00 x 123.95 x 115.57
E 355.60 x 123.70 x 89.66
F 425.50 x 123.95 x 127.00
N 177.80 x 123.70 x 83.31
Unsigned output voltages are isolated and can be used as either + or - polarities.
* May require jumpering or potentiometer adjustment.
Nominal Max Model Input Case Additional
Vout* Amps 100 to 264 VAC Type Features & Notes
Triple Output Models, 5V to 24Vout
+5, +12, –5* 2, 0.4, 0.4 HTAA-16W-AG AA A
5, +12, –5* 3, 1, 0.4 HBAA-40W-AG BAA A, C
+5, +12, –5* 6, 1, 0.4 HCAA-60W-AG D A, C
5, +12, –5* 6, 1.7, 0.7 HCBB-75W-AG CBB C
5, +12, –5* 8, 1.7, 0.7 CP131-AG CP131 A, C
5, +12, –5* 12, 1.7, 0.7 HDBB-105W-AG DBB A, C
5, +12, –12 2, 0.4, 0.4 HTAA-16W-AG AA A
5, +12, –12 3, 1, 1 HBAA-40W-AG BAA A, C
+5, +12, –12 6, 1, 1 HCAA-60W-AG D A, C
5, +12, –12 6, 1.7, 1.7 HCBB-75W-AG CBB C
5, +12, –12 8, 1.7, 1.7 CP131-AG CP131 A, C
5, +12, –12 12, 1.7, 1.7 HDBB-105W-AG DBB C
5, +12, –12 12, 3.4, 3.4 HDCC-150W-AG DCC A, C
5, +12, –15* 2, 0.4, 0.4 HTAA-16W-AG AA A
5, +12, –15* 3, 1, 0.8 HBAA-40W-AG BAA A, C
+5, +12, –15* 6, 1, 1 HCAA-60W-AG D A, C
5, +12, –15 6, 1.7, 1.5 HCBB-75W-AG CBB C
5, +12, –15 8, 1.7, 1.5 CP131-AG CP131 A, C
5, +12, –15* 12, 1.7, 1.5 HDBB-105W-AG DBB C
5, +12, –15 12, 3.4, 3 HDCC-150W-AG DCC A, C
5, +15, –5* 2, 0.4, 0.4 HTAA-16W-AG AA A
5, +15, –5* 3, 0.8, 0.4 HBAA-40W-AG BAA A, C
+5, +15, –5* 6, 1, 0.4 HCAA-60W-AG D A, C
5, +15, –5* 6, 1.5, 0.7 HCBB-75W-AG CBB C
5, +15, –5* 8, 1.5, 0.7 CP131-AG CP131 A,
5, +15, –5* 12, 1.5, 0.7 HDBB-105W-AG DBB C
5, +15, –12* 2, 0.4, 0.4 HTAA-16W-AG AA A
5, +15, –12* 3, 0.8, 1 HBAA-40W-AG BAA A, C
+5, +15, –12* 6, 1, 1 HCAA-60W-AG D A, C
5, +15, –12 6, 1.5, 1.7 HCBB-75W-AG CBB C
5, +15, –12 8, 1.5, 1.7 CP131-AG CP131 A, C
5, +15, –12* 12, 1.5, 1.7 HDBB-105W-AG DBB C
5, +15, –12 12, 3, 3.4 HDCC-150W-AG DCC A, C
5, +15, –15* 2, 0.4, 0.4 HTAA-16W-AG AA A
5, +15, –15* 3, 0.8, 0.8 HBAA-40W-AG BAA A, C
+5, +15, –15* 6, 1, 1 HCAA-60W-AG D A, C
5, +15, –15 6, 1.5, 1.5 HCBB-75W-AG CBB C
5, +15, –15 8, 1.5, 1.5 CP131-AG CP131 A, C
5, +15, –15* 12, 1.5, 1.5 HDBB-105W-AG DBB C
5, +15, –15 12, 3, 3 HDCC-150W-AG DCC A, C
Case Dimensions
Type (Inches)
AA 6.50 x 4.00 x 2.10
B 4.87 x 4.00 x 2.10
BAA 10.25 x 4.00 x 2.95
BB 7.00 x 4.87 x 2.95
C 5.62 x 4.87 x 2.95
CBB 11.00 x 4.87 x 3.28
CC 9.38 x 4.87 x 3.28
CP131 11.00 x 4.87 x 3.28
D 9.00 x 4.87 x 3.28
DBB 14.25 x 4.87 x 3.38
DCC 15.00 x 4.88 x 4.55
E 14.00 x 4.87 x 3.53
F 16.75 x 4.88 x 5.00
N 7.00 x 4.87 x 3.28
MCD10016 Rev. 1.2, 13-Nov-09 Page 4 of 9 www.power-one.com
Linear Power Supplies Data Sheet
(See Additional Features Column)
A Overvoltage protection, set at 6.2 V ±0.4 V.
B Non-adjustable 3-terminal regulator.
C Remote sense provided.
D With output inhibit and parallel
operation master/slave capability.
E With output inhibit.
F Adjustable 3-terminal regulator.
G Can be made into an isolated output by
removing jumper W1.
H Model requires 100 LFM forced-air
cooling above 75% of rated output
power at 50 degrees C.
Case Dimensions
Type (Millimeters)
AA 165.10 x 101.60 x 53.34
B 123.70 x 101.60 x 53.34
BAA 260.35 x 101.60 x 74.93
BB 177.80 x 123.70 x 74.93
C 142.75 x 123.70 x 74.93
CBB 279.40 x 123.70 x 83.31
CC 238.25 x 123.70 x 83.31
CP131 279.40 x 123.70 x 83.31
D 228.60 x 123.70 x 83.31
DBB 361.95 x 123.70 x 85.85
DCC 381.00 x 123.95 x 115.57
E 355.60 x 123.70 x 89.66
F 425.50 x 123.95 x 127.00
N 177.80 x 123.70 x 83.31
Unsigned output voltages are isolated and can be used as either + or - polarities.
* May require jumpering or potentiometer adjustment.
Linear Power Supplies Data Sheet
MCD10016 Rev. 1.2, 13-Nov-09 Page 5 of 9 www.power-one.com
Input Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Input Voltage - AC Jumper selectable, shipped factory configured for 100 VAC Tap 87 100 110
(Note 1, 2) 120VAC operation. All models must be externally 120 VAC Tap 104 120 132 VAC
fused for proper operation. Fuse ratings are marked 220 VAC Tap 191 220 242
on each unit. Consult factory for each unit’s fuse 240 VAC Tap 209 240 264
requirements.
Input Frequency AC input. 47 63 Hz
Line Regulation Output voltage charge for a 10% line change: F case models. -0.01 +0.01
HAD12, HAD15. -1.0 +1.0 %
Outputs with adjustable three terminal regulators. -0.5 +0.5
All other models. -0.05 +0.05
NOTES: 1) Derate output current 10% for 50Hz operation.
2) Input voltage tolerance for 230VAC operation is +15%, -10%.
Output Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Output Adjustment Minimum output adjustment range (Note 1). -5 +5 %
Efficiency 5 volt outputs. 45
12 volt and 15 volt outputs. 55 %
24 volt and higher outputs. 60
F case models. 3.0 mVPK-PK
Ripple and Noise 5 volt, 12 volt, and 15 volt models. 5.0 mVPK-PK
(Note 2) All three terminal regulator outputs. 0.2 %PK-PK
24 volt through 250 volt models. 3.0mVPK-PK plus 0.02% of output voltage, max
Load Regulation Output change for a 50% load change: F case models. -0.02 +0.02
HAD12, HAD15. -1 +1 %
Outputs with adjustable three terminal regulators. -0.5 +0.5
All other models. -0.05 +0.05
Transient Response Recovery time, to within 1% of initial set point due to a 50% load change. 50 μs
NOTES: 1) OUTPUT VOLTAGE ADJUSTMENTS: Output voltage adjustments can be made to within ±5% of factory setting of nominal output voltage. Locate the “Vadj”
potentiometer on the power supply PCB and use a screwdriver to adjust the output pot. The HAD12 and HAD15 3 terminal regulator outputs are not
adjustable.
2) Full load, 20MHz bandwidth.
Safety, Regulatory, and EMI Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Agency Approvals UL60950-1.
CSA 60950-1 “cUL”. Approved
EN60950-1.
IEC60950-1.
Dielectric Withstand Input to output. 3000 VAC
Voltage Input to ground. 1500
Electromagnetic FCC CFR title 47 Part 15 Sub-Part B - conducted.
Interference EN55022 / CISPR 22 conducted. Compatible with system compliance to Level B.
EN55022 / CISPR 22 radiated.
Leakage Current Per EN60950 (264VAC) 23 50 μA
Interface Signals and Internal Protection
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Overvoltage Protection Provided on 5 volt output units where indicated. 5.8 6.6 V
Other outputs may use optional overvoltage protectors OVP-12 and OVP-24.
Remote Sense Total voltage compensation for cable losses with respect to the main output. 250 mV
Provided on models where indicated.
Overcurrent/Short Circuit Automatic current limit/foldback. Rated as a percentage of output power. 115 120 140 %
Protection
Master/Slave Operation For parallel operation of up to 6 units. Master/slave pin provided on F case models only. Contact factory for application notes.
MCD10016 Rev. 1.2, 13-Nov-09 Page 6 of 9 www.power-one.com
Linear Power Supplies Data Sheet
Environmental Specifications
PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS
Operating Temperature Derate output power linearly above 50°C by 3% per °C. At 100% load 0 50 °C
At 40% load 70 °C
Storage Temperature -40 85 °C
Temperature Coefficient 0°C to 50°C (after 15 minute warm-up). 0.1 0.3 %/°C
24 hours after warm-up. -0.3 +0.3 %
Shock Operating. 20 GPK
Vibration Random vibration from 10 Hz to 2 kHz, 3 axis. 6.15 GRMS
Relative Humidity Non-Condensing. 5 95 %RH
Linear Power Supplies Data Sheet
MCD10016 Rev. 1.2, 13-Nov-09 Page 7 of 9 www.power-one.com
MCD10016 Rev. 1.2, 13-Nov-09 Page 8 of 9 www.power-one.com
Linear Power Supplies Data Sheet
Linear Power Supplies Data Sheet
MCD10016 Rev. 1.2, 13-Nov-09 Page 9 of 9 www.power-one.com
NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components
in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective
divisional president of Power-One, Inc.
TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the
date manufactured. Specifications are subject to change without notice.