AD2412N3L-VI Data Sheet
WORLDWIDE OFFICES
Americas
2900 S.Diablo Way
Tempe, AZ 85282
USA
+1 888 412 7832
Europe (UK)
Waterfront Business Park
Merry Hill, Dudley
West Midlands, DY5 1LX
United Kingdom
+44 (0) 1384 842 211
Asia (HK)
14/F, Lu Plaza
2 Wing Yip Street
Kwun Tong, Kowloon
Hong Kong
+852 2176 3333
For more information: www.artesyn.com/power
For support: productsupport.ep@artesyn.com
Artesyn Embedded Technologies, Artesyn and the Artesyn Embedded Technologies logo are trademarks
and service marks of Artesyn Embedded Technologies, Inc. All other names and logos referred to are
trade names, trademarks, or registered trademarks of their respective owners. Specifications are subject
to change without notice. © 2017 Artesyn Embedded Technologies, Inc. All rights reserved. For full legal
terms and conditions, please visit www.artesyn.com/legal.
www.artesyn.com
AD2412N3L-VI DS 14Aug2017
Mechanical Drawing
Ordering Information
Model Number Maximum
Power
Output
Voltage
Minimum
Load
Maximum
Load Peak Load1Regulation2Ripple
P/P (PARD)3,4
AD2412N3L-VI 24 W 12 Vdc 0.1 A 2 A 2.4 A ± 5% < 120 mV
1. Peak current lasting 200 ms every 3 seconds.
2. At 25 ºC including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings.
3. Peak-to-peak with 20 MHz bandwidth and 10μF (tantalum capacitor) in parallel with a 0.1 μF capacitor at rated line voltage and load ranges.
4. Ripple 240 mV at -20 °C; 120 mV after 30 minutes warm-up time
5. Surge Criteria A: Equipment shall withstand the test without damage and shall operate within the specified performance limits after the test without manual intervention.
Surge Criteria B: Equipment may be damage but will not cause any fire or safety hazard
Environmental Specications
Operating temperature -20 °C to +50 °C ambient (with warm-up period)
Storage temperature -45 °C to +85 °C
Electromagnetic susceptibility
Designed to meet EN61000-4-2, -4, -5, level 3; EN61000-4-3, -6, 6v/m; EN61000-3-3 and EN61000-3-2
Class A
Humidity Operating; non-condensing 5% to 90% RH
MTBF calculated > 850,000 hours at full load and 25 °C ambient conditions
Telcoredia SR332 issue 1 (Method 1, Case 3)
AC INLET
1.89"
(48)
4.13"
(105)
47.25"
(1200 )
MODEL LABEL
1.30"
(33)
Notes:
1. Specifications subject to change
without notice.
2. All dimensions in inches (mm),
tolerance is ± 0.02” (±0.5 mm)
3. Warranty: 2 years
4. Weight: 0.61 lb./ 0.28 kg
5. AC input power cord sold separately
6. Specifications at factory settings
at 115 Vac input, 25 °C unless
otherwise stated
7. AC Input Connector: IEC320, C13