HN27C101AG/HN27C301AG Series
6
Capacitance (Ta = 25°C, f = 1 MHz)
Parameter Symbol Min Typ Max Unit Test Conditions
Input capacitance Cin — — 10 pF Vin = 0 V
Output capacitance Cout — — 15 pF Vout = 0 V
Read Operation
DC Characteristics (VCC = 5 V ± 5%, VPP = VCC, Ta = 0 to +70°C) (HN27C101AG/HN27C301AG-10)
(VCC = 5 V ± 10%, VPP = VCC, Ta = 0 to +70°C)
(HN27C101AG/HN27C301AG-12/15/17/20/25)
Parameter Symbol Min Typ Max Unit Test Conditions
Input leakage current ILI ——2 µA Vin = 0 V to VCC
Output leakage current ILO ——2 µA Vout = 0 V to VCC
VPP current IPP1 —1 20µAV
PP = 5.5 V
Standby VCC current ISB1 ——1 mACE = VIH
ISB2 —1 20µACE = VCC ± 0.3 V
Operating VCC current ICC1 ——30mACE = VIL, Iout = 0 mA
ICC2 — — 30 mA f = 5 MHz, Iout = 0 mA
— — 50 mA f = 10 MHz, Iout = 0 mA
Input low voltage VIL –0.3*1— 0.8 V
Input high voltage VIH 2.2 — VCC +
1.0*2V
Output low voltage VOL — — 0.45 V IOL = 2.1 mA
Output high voltage VOH 2.4 — — V IOH = –1 mA
VCC – 0.7 — — V IOH = –0.1 mA
Notes: 1. VIL min = –1.0 V for pulse width ≤ 50 ns
2. VIH max = VCC +1.5 V for pulse width ≤ 20 ns
If VIH is over the specified maximum value, read operation cannot be guaranteed.