Easy-wire connectors for Industrial Components XN2 Easy-wire Connectors with * Specifications; Ideal for Connecting Sensors. * Uses industry-proven spring clamps for wiring. * No special tools required for easy wiring. * Easy to rewire and repair * Each Connector accepts any wire size from AWG28 (0.08 mm2) to AWG20 (0.5 mm2). (External sheath diameter: 1.5 mm max.) * RoHS Compliant *E-con specifications are currently being promoted for standardization by manufacturers of FA components and connectors. Wiring Configuration Example Connecting to FA Components * FA components with industrystandard sensor connectors XN2A Sensor with prewired cable Linking cables * Original Controller PCBs XN2A XN2D XN2A * FA components that connect via terminal blocks XN2B Ordering Information Type Cable Plug Connector Cable Socket Connector Single-socket PCB Socket Connector Four-socket PCB Socket Connector Model Model Model Model XN2A-1370 XN2A-1470 XN2A-1570 XN2A-1670 XN2A-1870 --XN2B-1470 ------- XN2D-1371 XN2D-1471 XN2D-1571 XN2D-1671 XN2D-1871 --XN2D-4471 ------- Appearance No. of contacts 3 4 5 6 8 Easy-wire connectors for Industrial Components XN2 181 Ratings and Specifications Rated current Rated voltage Contact resistance (See note 1.) Insulation resistance Dielectric strength Insertion tolerance Ambient temperature (See note 2.) Applicable wires (See note 3.) 3 A/pole, using AWG20 (0.5 mm2) wire 2 A/pole, using AWG22 (0.3 mm2) wire 1 A/pole, using AWG24 (0.2 mm2) wire 0.5 A/pole, using AWG26 (0.1 mm2)or AWG28 (0.08 mm2) wire 32 VDC 30 m max. (20 mVDC max., 100 mA max.) 1,000 M min. (at 500 VDC) 1,000 VAC for 60 s (leakage current: 1 mA max.) 50 times Operating: -30C to 75C 0.08 mm2 (AWG28) to 0.5mm2 (AWG20) The external diameter of the cable sheath is 1.5 mm max. Note: 1. This value is the contact resistance of the connector. 2. The temperature is limited, however, to the maximum operating temperature for the cables. 3. Avoid using wires with a single strand diameter of 0.16 mm or smaller. Materials and Finish Item Housing Cover Base Lever Contact Cable Types Black PBT resin (UL94V-0) Black PBT resin (UL94V-0) Transparent PC resin (UL94V-0) PA resin (UL94V-0)/natural (white) Phosphor bronze/Underplating: Nickel (1.5 to 3.0 m) Contacts: Gold (0.2 m min.) Terminals: Tin plating (1.0 m min.) Stainless steel --- Spring Fastening pins PCB Types ------- --Copper alloy/nickel base with tin plating Dimensions (Unit: mm) Cable Plug Connector XN2A-1@70 1.2 dia. (internal) 1.65 dia. (external) 18 3.3 17.6 Dimensions C A Dimension (mm) B 2 (pitch) 1.1 1.05 3.4 6 5.05 1.65 7.5 (Strip gauge) 182 Easy-wire connectors for Industrial Components XN2 No. of contacts 3 4 5 6 8 A B C 4.0 6.0 8.0 10.0 14.0 7.2 9.2 11.2 13.2 17.2 13.8 15.8 17.8 19.8 23.8 Cable Socket Connector XN2B-1470 23.2 12.3 15.8 6 12.85 8.9 2 (pitch) 6.75 3.1 6 6.4 Single-socket PCB Socket Connector XN2D-1@71 5.2 3.1 3.3 Applicable PCB Dimensions (Top View) 4-C1 D C 20.05 (pitch) B A +0.05 -0.10 C D 1 E 2 (pitch) B E Dimensions 0.2 Dimension (mm) 13 dia. 6.4 Exterior of Single-socket PCB Connector 6.4 t=1.60.2 No. of contacts 3 4 5 6 8 (3.5) A B C D E 6.9 8.9 10.9 12.9 16.9 5.8 6.8 7.8 8.8 10.8 4.0 6.0 8.0 10.0 14.0 8.0 10.0 12.0 14.0 18.0 13.8 15.8 17.8 19.8 23.8 Four-socket PCB Socket Connector XN2D-4471 3.3 6.75 1 6 2 (pitch) 15.8 3.1 0.2 8.9 Applicable PCB Dimensions (Top View) t=1.60.2 19.50.1 6.50.05 (pitch) +0.05 1-0.10 dia. 20.05 (pitch) 25.9 19.5 6.5 (pitch) 6.75 60.1 9.05 10.05 3.2 3.2 Exterior of Four-socket PCB Connector 13 Easy-wire connectors for Industrial Components XN2 183 Assembly Instructions Preparing the Cable Align the cable with the guide marked STRIP GAUGE on the side of the Connector, strip 7 to 8 mm of the cable sheath, and then twist the wires several times. 4. Make sure that the following operations have been performed. * Check that the operating lever is reset. * Check that the procedure in step 2 has been followed. (Pull gently on the cable to make sure that there is resistance, indicating that the Connectors are wired correctly.) 7 to 8 mm Connecting the Cable to the Connector 1. Use a flat-blade screwdriver to push down the operating lever inside the operation slot until it locks. Flat-blade screwdriver Operation slot 2. Insert the wire fully to the back of the wire insertion hole. Make sure that the cable sheath is inserted into the hole, and that the end of the wire has passed through the contact section. Contact section Cable sheath Wire insertion hole Removing Cables from the Connector 1. Press down on the operating lever to lock the lever before removing the cable. 2. After removing the cable from the Connector, always reset the operating lever, except when rewiring the Connector. The Connector can be rewired without resetting the operating lever. Operating lever (white) 3. Insert the screwdriver into the release slot, and gently pull back the lever until a click is heard by resetting the lever. Operating lever (white) 184 Release slot Easy-wire connectors for Industrial Components XN2 Safety Precautions General Precautions Precautions for Correct Use * Do not pull on the Connectors or cables. Doing so may cause damage to the Connectors or cause the cables to disconnect. * Install the Connectors in a location where they will not be stepped on, to prevent disconnection of the cables or damage to the Connectors. If the Connectors have to be installed in such a location, use a protective cover. * Make sure that the Connectors are mated in the correct direction. Mating the Connectors incorrectly will damage to the Connectors. * Do not use the Connectors if the lock lever is bent or broken. Doing so may cause the Connector to become loose or the device to malfunction. * Before mounting Connectors to a PCB, make sure that the Connectors are positioned in the correct direction. * Before bending a cable to connect it to a Connector, check the bending specifications of the cable to be used. * Do not exceed the rated current of the cable. Always check the rated current of each cable to be used. * Do not use pliers or other tools to remove the Connectors. * Hold the Connectors firmly by hand when handling them. Do not use excessive force to push the Connectors. Forcing the Connectors may result in injury. * These Connectors do not resist water. Do not use Connectors in places where water or oil may be sprayed onto the Connectors. Do not use the product in atmospheres or environments that exceed product ratings. Wiring * Insert one wire into each insertion hole. Inserting two or more wires into a single hole may cause unexpected problems. * Make sure that no power is being supplied to a Connector before wiring, inserting, or removing the Connector. Doing so may result in electric shock. * Follow the wiring diagrams for the device being used when wiring the cables. * Strip the cables according to the instructions in the applicable operation manual, making sure not to damage the wires. * Do not use a screwdriver with a tip larger than the specified width when wiring the Connectors. * Make sure short-circuits are not created, e.g., by protruding wires. Inserting and Removing Connectors * When connecting or disconnecting Connectors, always hold the case of the Connector. * When mating Connectors, insert the Connector fully into the back of the socket, and then make sure that the Connector will not become loose by lightly pulling it in the opposite direction. Recommended Screwdriver * Use a flat-blade screwdriver with a tip of 2 mm max. Do not use screwdrivers that gradually widen towards the base of the screwdriver. * Using other screwdrivers may cause damage to the adjacent poles. Easy-wire connectors for Industrial Components XN2 185 All sales are subject to Omron Electronic Components LLC standard terms and conditions of sale, which can be found at http://www.components.omron.com/components/web/webfiles.nsf/sales_terms.html ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. OMRON ON-LINE OMRON ELECTRONIC COMPONENTS LLC Global - http://www.omron.com USA - http://www.components.omron.com 55 E. Commerce Drive, Suite B Schaumburg, IL 60173 847-882-2288 Cat. No. X304-E-1a 06/14 (11/10) Specifications subject to change without notice Easy-wire connectors for Industrial Components XN2 Printed in USA