POWER DETECTORS - SMT
12
12 - 2
HMC600LP4 / 600LP4E
General Description
Features
Functional Diagram
The HMC600LP4(E) Logarithmic Detector/Controller
converts RF signals at its input, to a proportional DC
voltage at its output. The HMC600LP4(E) employs
a successive compression topology which delivers
extremely high dynamic range and conversion accuracy
over a wide input frequency range. As the input power
is increased, successive ampli ers move into saturation
one by one creating an accurate approximation of the
logarithm function. The output of a series of square law
detectors is summed, converted into voltage domain
and buffered to drive the LOGOUT output. For detection
mode, the LOGOUT pin is shorted to the VSET input,
and will provide a nominal logarithmic slope of 19mV/dB
and an intercept of -95 dBm. The HMC600LP4(E) can
also be used in the controller mode where an external
voltage is applied to the VSET pin, to create an AGC or
APC feedback loop.
Wide Dynamic Range: up to 75 dB
Flexible Supply Voltage: +2.7V to +5.5V
Power-Down Mode
Excellent Stability over Temperature
Compact 4x4mm Leadless SMT Package
Typical Applications
The HMC600LP4 / HMC600LP4E is ideal for IF and
RF applications in:
• Cellular/PCS/3G
• WiMAX, WiBro & Fixed Wireless
• Power Monitoring & Control Circuitry
• Receiver Signal Strength Indication (RSSI)
• Automatic Gain & Power Control
Electrical Speci cations, TA = +25C, PWD = 0V, Vcc1, Vcc2 = +3.3V [1]
Parameter Typ. Typ. Typ. Typ. Typ. Typ. Typ. Typ. Units
Input Frequency 50 100 500 900 1900 2500 3500 4000 MHz
±3 dB Dynamic Range 74 74 74 74 70 66 51 48 dB
±3 dB Dynamic Range Center -30 -30 -30 -30.5 -31.0 -31.0 -27 -23.5 dBm
±1 dB Dynamic Range 64 64 64 65 62 59 44 41 dB
Output Slope 19.6 19.5 19.4 19.2 19.1 19.5 21.0 22.3 mV/dB
Output Intercept -96 -96 -96 -96 -95 -93 -79 -72 dBm
Temperature Sensitivity @ -10 dBm Input [2] -2.7 -2.8 -3.6 -4.8 -6.9 -7.4 -8.3 -12.9 mdB/°C
[1] Detector mode measurements; LOGOUT (Pin 17) is shorted to VSET (Pin 16).
[2] Measured from TA = -40C to TA = +85C
Parameter Conditions Min. Typ. Max. Units
RF Input (INP)
Return Loss F = 50 - 4000 MHz, Zo = 50Ω, See plot 10 dB
LOGOUT Interface
Open Loop Impedance 16 kΩ
Current Drive (Source) 0.4 mA
75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
v02.0909
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 3
Electrical Speci cations, (continued)
HMC600LP4 / 600LP4E
Parameter Condition
Vcc1, Vcc2 +3.3V
Input Zo 50Ω
TA+25C
Fin 900 MHz
INN Port connected to ground through a 1000pF capacitor
Test Conditions
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 50 MHz
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-75 -65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
Parameter Conditions Min. Typ. Max. Units
Current Drive (Sink) For 1% change in the output voltage 2.25 mA
Output Voltage Range 0Vcc -0.13V
Small Signal Response Time (10% to 90%) Pin = -60 to -57 dBm 50 ns
Large Signal Response Time
(±0.5 dB Settling) Pin = No Signal to 0 dBm 150 ns
Output Rise Time From 0% to 90% 90 ns
Ripple Fin = 100 MHz <2 mVpp
VSET Interface
Input Impedance 30
Input Voltage Range 0.6 to 1.9 V
Low Frequency Gain VSET to LOGOUT 78 dB
Open Loop Corner Frequency 1.6 kHz
Power Down (PWD) Interface
Voltage Range for Normal Mode 0 0.2 x Vcc V
Voltage Range for Shutdown Mode 0.8 x Vcc Vcc V
Threshold Voltage Vcc/2 V
Power-up Response Time 50% PWD to ±0.5 dB Settling of LOGOUT 1 μs
Power-Down Response Time 50% PWD to 10% Icc 2.5 μs
Power Supply (Vcc1, Vcc2)
Operating Voltage Range 2.7 5.5 V
Supply Current in Normal Mode Vcc = +3.3V, PWD = 0V 29 36 mA
Supply Current in Power Down Mode Vcc = +3.3V, PWD = Vcc 1 mA
LOGOUT Voltage & Error
vs. Input Power, Fin = 100 MHz
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-75 -65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 4
LOGOUT Voltage & Error
vs. Input Power, Fin = 3500 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 4000 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 2500 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 1900 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 500 MHz
LOGOUT Voltage & Error
vs. Input Power, Fin = 900 MHz
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
HMC600LP4 / 600LP4E
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-75 -65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-75 -65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER
(
dBm
)
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-75 -65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-75 -65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
0
0.4
0.8
1.2
1.6
2
-5
-3
-1
1
3
5
Ideal
LOGOUT +25 C
LOGOUT +85 C
LOGOUT -40 C
ERR +25 C
ERR +85 C
ERR -40 C
-65 -55 -45 -35 -25 -15 -5 5
LOGOUT (V)
ERROR (dB)
INPUT POWER (dBm)
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 5
LOGOUT Intercept vs. Frequency,
Vcc = +3.3V
LOGOUT Intercept vs. Bias Voltage
TA = +25C
LOGOUT Slope vs. Frequency,
Vcc = 3.3V
LOGOUT Slope vs. Supply Voltage,
TA = +25C
HMC600LP4 / 600LP4E
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
18
19
20
21
22
23
24
25
2.5 3 3.5 4 4.5 5 5.5
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
SLOPE (mV/dB)
Vcc (V)
-100
-90
-80
-70
-60
-50
2.5 3 3.5 4 4.5 5 5.5
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
INTERCEPT (dBm)
Vcc (V)
-100
-90
-80
-70
-60
-50
0 1000 2000 3000 4000
+25 C
+85 C
-40 C
INTERCEPT (dBm)
FREQUENCY (MHz)
18
19
20
21
22
23
24
25
0 1000 2000 3000 4000
+25 C
+85 C
-40 C
SLOPE (mV/dB)
FREQUENCY (MHz)
LOGOUT Error vs. Input Power,
Normalized[2], Fin = 1900 MHz Input Return Loss
-35
-30
-25
-20
-15
-10
-5
0
012345
+25 C
+85 C
-40 C
INPUT RETURN LOSS (dB)
FREQUENCY (GHz)
-2
-1
0
1
2
-70 -55 -40 -25 -10 5
+85 C
-40 C
NORMALIZED ERROR (dB)
INPUT POWER (dBm)
[1] Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
[2] This data is relative to the room temperature performance of the HMC600LP4
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 6
Absolute Maximum Ratings
Vcc1, Vcc2 0V to +5.5V
PWD 0V to +5.5V
VSET Input Voltage 0V to +5.5V
LOGOUT Output Current 3 mA
RF Input Power +12 dBm
Junction Temperature 125 °C
Continuous Pdiss (T = 85°C)
(Derate 7.95 mW/°C above 85°C) 0.32 Watts
Thermal Resistance (Rth)
(junction to lead) 126 °C/W
Storage Temperature -65 to +150 °C
Operating Temperature -40 to +85 °C
ESD Sensitivity (HBM) Class 1C
Outline Drawing
ELECTROSTATIC SENSITIVE DEVICE
OBSERVE HANDLING PRECAUTIONS
NOTES:
1. LEADFRAME MATERIAL: COPPER ALLOY
2. DIMENSIONS ARE IN INCHES [MILLIMETERS].
3. LEAD SPACING TOLERANCE IS NON-CUMULATIVE
4. PAD BURR LENGTH SHALL BE 0.15mm MAXIMUM.
PAD BURR HEIGHT SHALL BE 0.05mm MAXIMUM.
5. PACKAGE WARP SHALL NOT EXCEED 0.05mm.
6. ALL GROUND LEADS AND GROUND PADDLE MUST
BE SOLDERED TO PCB RF GROUND.
7. REFER TO HITTITE APPLICATION NOTE FOR SUGGESTED
PCB LAND PATTERN.
HMC600LP4 / 600LP4E
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
LOGOUT Voltage vs. Input Power
and Frequency, TA = +25C
0.5
1
1.5
2
-75 -65 -55 -45 -35 -25 -15 -5 5
50 MHz
900 MHz
1900 MHz
3500 MHz
4000 MHz
LOGOUT (V)
INPUT POWER (dBm)
Unless otherwise noted: Vcc1, Vcc2 = +3.3V, TA = +25C
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 7
Part Number Package Body Material Lead Finish MSL Rating Package Marking [3]
HMC600LP4 Low Stress Injection Molded Plastic Sn/Pb Solder MSL1 [1] H600
XXXX
HMC600LP4E RoHS-compliant Low Stress Injection Molded Plastic 100% matte Sn MSL1 [2] H600
XXXX
[1] Max peak re ow temperature of 235 °C
[2] Max peak re ow temperature of 260 °C
[3] 4-Digit lot number XXXX
Package Information
HMC600LP4 / 600LP4E
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Pin Number Function Description Interface Schematic
1, 6, 7-13,
15, 18-24 N/C
These pins are not connected internally; however,
this product is speci ed with these pins connected
to RF/DC ground.
2, 6 Vcc1, Vcc2 Bias supply. Connect supply voltage to both pins.
3, 4 INP, INN RF Input pins. Connect RF to INP, and AC couple
INN to ground for single-ended operation.
14 PWD
Connect to 0V for normal operation. Applying voltage
>0.8 x Vcc will initiate a power saving shutdown mode.
To ensure proper start-up apply the power-up sequence
shown in the “Power-Up Timing Diagram” attached to the
application circuit.
16 VSET VSET input in controller mode. Short this
pin to LOGOUT for detector mode.
17 LOGOUT
Logarithmic output that converts the input power
to a DC level in detector mode. Short this pin to
VSET for detector mode.
Package
Base GND Exposed paddle must be connected to RF and DC ground.
Pin Descriptions
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 8
Item Description
J1 - J4 PC Mount SMA Connector
J5 - J8 DC Pin
C1, C2 1000 pF Capacitor, 0402 Pkg.
C3, C4 0.1μF Capacitor, 0402 Pkg.
R1, R2 5.6Ω Resistor, 0603 Pkg.
R3-R5 0Ω Resistor, 0603 Pkg.
U1 HMC600LP4 / HMC600LP4E
Logarithmic Detector / Controller
PCB [2] 115244 Evaluation PCB
[1] Reference this number when ordering complete evaluation PCB
[2] Circuit Board Material: Rogers 4350
Evaluation PCB
The circuit board used in the  nal application should
use RF circuit design techniques. Signal lines
should have 50 ohm impedance while the package
ground leads and exposed paddle should be con-
nected directly to the ground plane similar to that
shown. A sufficient number of via holes should be
used to connect the top and bottom ground planes.
The evaluation circuit board shown is available from
Hittite upon request.
List of Materials for Evaluation PCB 115242 [1]
HMC600LP4 / 600LP4E
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
For price, delivery, and to place orders, please contact Hittite Microwave Corporation:
20 Alpha Road, Chelmsford, MA 01824 Phone: 978-250-3343 Fax: 978-250-3373
Order On-line at www.hittite.com
POWER DETECTORS - SMT
12
12 - 9
HMC600LP4 / 600LP4E
v02.0909 75 dB LOGARITHMIC
DETECTOR / CONTROLLER 50 - 4000 MHz
Application & Evaluation PCB Schematic
Notes
Note 1: The HMC600LP4 & HMC600LP4E evaluation boards are pre-assembled for single-ended input, and detector/RSSI mode.
Note 2: For single-ended input operation, use the INP port and make no connection to INN. INN is AC coupled to ground by C2
Note 3: For differential input, remove C2, and install a 1000pF capacitor in series with INN at location shown.
Note 4: For detector mode, connect high impedence volt meter to the LOGOUT port, and make no connection to VSET. LOGOUT
is shorted to VSET by R3, as required for detector mode.
Note 5: For controller mode, remove R3 and make appropriate connection to LOGOUT and VSET. In controller mode, the
LOGOUT output can be used to drive a variable gain ampli er, or a variable attenuator, either directly or through a buffer
or microcontroller. VSET should be connected to an external supply, typically between +0.6 and +1.9V.