Complete Assemblies A22 Pushbutton Switches -- 22 mm Install in 22-mm dia. or 25-mm dia. Panel Cutout H Locking lever ensures easy mounting and removal of switch unit H Increase wiring efficiency and decrease mounting depth with three-row mounting of switch unit contact blocks H Finger protection mechanism on switch unit provided as a standard feature c H Use optional 25-mm dia. ring to install in 25-mm dia. panel cutouts H IP65 oil resistant: EN60947-5-1 This product was manufactured at OMRON Izumo. OMRON Izumo has obtained approvals from international certification bodies for its quality system and environmental control system. Ordering Information J CONSTRUCTION Operational Unit * Lock Fitting Available Colors Non-illuminated: Red, green, yellow, white, blue, black Illuminated: Red, green, yellow, white, blue Lamp * Light Source LED Lamp Incandescent Lamp Switch Unit (Illuminated model shown) * Contacts SPST-NO, SPST-NC, SPST-NO + SPST-NC, DPST-NO, DPST-NC * Lighting Method Non-illuminated Illuminated (without transformer) Illuminated (with transformer) (Actual color of yellow pushbuttons more closely resembles amber than true yellow.) 2 A22 A22 J PART NUMBER LEGEND (COMPLETE ASSEMBLY) Shipped as a set which includes the Operational Unit, LED (Illuminated type only), and switch unit with contact blocks. 1 2 3 4 5 6 A22j-jj-j-jj 1 Illuminated/Non-illuminated Code Description 5 Contacts 3 Operator Color Code Description Code Description SPST-NO None Non-illuminated R Red 10 L G Green 01 SPST-NC Y Yellow 11 SPST-NO + SPST-NC White 20 DPST-NO A Blue 02 DPST-NC B Black (for Non-illuminated type only) Illuminated 2 Flange Shape Non-illuminated W Note: SPST= Single Pole, Single Throw DPST= Double Pole, Single Throw Code Description F Round/Flush T Round/Extended G Round/Full-guard H Round/Half-guard C Square/Extended Code Rated Voltage Code Description D Square/Full-guard 6D LED 6 VDC M Momentary S Round/Mushroom (30-mm dia.) 6A 6 VAC A Latching (See note) M Round/Mushroom (40-mm dia.) 4 Light Source 6 Switch Action Without transformer 12A 12 VAC/DC Illuminated 24A 24 VAC/DC T Round/Extended With transformer G Round/Clear full-guard T1 H Round/Half-guard T2 C Square/Extended D Square/Full-guard LED Note: Also referred to as "Alternate Action Switch Action." 110 VAC*1 220 VAC*2 *1) Operational voltage: 95 to 115 VAC *2) Operational voltage: 190 to 230 VAC Note: With Transformer types the LED lamp (24 VAC/DC) can be lit by directly applying 110 VAC/DC (220 VAC/DC) to the lamp terminal. The LED is the 24-VAC/DC type. (Actual color of yellow pushbuttons more closely resembles amber than true yellow.) 3 A22 A22 J PUSHBUTTON SWITCH (COMPLETE ASSEMBLY) Non-illuminated (Round Type) Description Part number Appearance Contacts Operator color Momentary operation Latching operation Round Flush type yp SPST-NO Insert one of the f ll i lletters iinto the following h box j. j A22-Fj-10M A22-Fj-10A A22-Fj-01M A22-Fj-01A A22-Fj-11M A22-Fj-11A A22-Fj-20M A22-Fj-20A A22-Fj-02M A22-Fj-02A A22-Tj-10M A22-Tj-10A A22-Tj-01M A22-Tj-01A SPST-NO + SPST-NC A22-Tj-11M A22-Tj-11A DPST-NO A22-Tj-20M A22-Tj-20A DPST-NC A22-Tj-02M A22-Tj-02A SPST-NO A22-Gj-10M A22-Gj-10A SPST-NC A22-Gj-01M A22-Gj-01A SPST-NO + SPST-NC A22-Gj-11M A22-Gj-11A DPST-NO A22-Gj-20M A22-Gj-20A DPST-NC A22-Gj-02M A22-Gj-02A A22-Hj-10M A22-Hj-10A A22-Hj-01M A22-Hj-01A A22-Hj-11M A22-Hj-11A A22-Hj-20M A22-Hj-20A A22-Hj-02M A22-Hj-02A A22-Sj-10M A22-Sj-10A A22-Sj-01M A22-Sj-01A SPST-NO + SPST-NC A22-Sj-11M A22-Sj-11A DPST-NO A22-Sj-20M A22-Sj-20A DPST-NC A22-Sj-02M A22-Sj-02A SPST-NO A22-Mj-10M A22-Mj-10A SPST-NC A22-Mj-01M A22-Mj-01A SPST-NO + SPST-NC A22-Mj-11M A22-Mj-11A DPST-NO A22-Mj-20M A22-Mj-20A DPST-NC A22-Mj-02M A22-Mj-02A SPST-NC SPST-NO + SPST-NC DPST-NO DPST-NC Round/Extended t type Round/Full-guard / g type Round/Half-guard / g type SPST-NO SPST-NC SPST-NO SPST-NC SPST-NO + SPST-NC DPST-NO DPST-NC Small-size Mushroom t type (30-mm (30 di dia. head) h d) Medium-size Mushroom type (40-mm (40 mm dia head) SPST-NO SPST-NC R (red) Y (yellow) G (g (green)) W (white) ( hit ) A (blue) B (black) Insert one of the f ll i lletters iinto the following h box j. j R (red) Y (yellow) G (g (green)) W (white) ( hit ) A (blue) B (black) Non-illuminated (Square Type) Description Part number Appearance Contacts Operator color Momentary operation Latching operation Square/Extended q / type SPST-NO Insert one of the f ll i lletters iinto the following h box j. j A22-Cj-10M A22-Cj-10A A22-Cj-01M A22-Cj-01A A22-Cj-11M A22-Cj-11A A22-Cj-20M A22-Cj-20A A22-Cj-02M A22-Cj-02A A22-Dj-10M A22-Dj-10A A22-Dj-01M A22-Dj-01A SPST-NO + SPST-NC A22-Dj-11M A22-Dj-11A DPST-NO A22-Dj-20M A22-Dj-20A DPST-NC A22-Dj-02M A22-Dj-02A SPST-NC SPST-NO + SPST-NC DPST-NO DPST-NC Square/Full q / guard g type SPST-NO SPST-NC R (red) Y (yellow) G (g (green)) W (white) ( hit ) A (blue) B (b (black) ac ) 4 A22 A22 Illuminated (Round Type) Description Part number Appearance Contacts Rated voltage Illuminated operator color Momentary operation Latching operation Round/Extended / type SPST-NO 6 VDC Insert one of the h following f ll i letters into the box j. A22L-Tj-6D-10M A22L-Tj-6D-10A A22L-Tj-6A-10M A22L-Tj-6A-10A A22L-Tj-12A-10M A22L-Tj-12A-10A R (red) Y (y (yellow)) G ((green)) W (white) A (blue) A22L-Tj-24A-10M A22L-Tj-24A-10A A22L-Tj-6D-01M A22L-Tj-6D-01A A22L-Tj-6A-01M A22L-Tj-6A-01A A22L-Tj-12A-01M A22L-Tj-12A-01A 24 VAC/DC A22L-Tj-24A-01M A22L-Tj-24A-01A 6 VDC A22L-Tj-6D-11M A22L-Tj-6D-11A 6 VAC A22L-Tj-6A-11M A22L-Tj-6A-11A 12 VAC/DC A22L-Tj-12A-11M A22L-Tj-12A-11A 24 VAC/DC A22L-Tj-24A-11M A22L-Tj-24A-11A 6 VDC A22L-Tj-6D-20M A22L-Tj-6D-20A 6 VAC A22L-Tj-6A-20M A22L-Tj-6A-20A 12 VAC/DC A22L-Tj-12A-20M A22L-Tj-12A-20A 24 VAC/DC A22L-Tj-24A-20M A22L-Tj-24A-20A 6 VDC A22L-Tj-6D-02M A22L-Tj-6D-02A 6 VAC A22L-Tj-6A-02M A22L-Tj-6A-02A 12 VAC/DC A22L-Tj-12A-02M A22L-Tj-12A-02A 24 VAC/DC A22L-Tj-24A-02M A22L-Tj-24A-02A 110 VAC A22L-Tj-T1-10M A22L-Tj-T1-10A 220 VAC A22L-Tj-T2-10M A22L-Tj-T2-10A 110 VAC A22L-Tj-T1-01M A22L-Tj-T1-01A 220 VAC A22L-Tj-T2-01M A22L-Tj-T2-01A SPST-NO + SPST NC SPST-NC 110 VAC A22L-Tj-T1-11M A22L-Tj-T1-11A 220 VAC A22L-Tj-T2-11M A22L-Tj-T2-11A DPST-NO 110 VAC A22L-Tj-T1-20M A22L-Tj-T1-20A 220 VAC A22L-Tj-T2-20M A22L-Tj-T2-20A 110 VAC A22L-Tj-T1-02M A22L-Tj-T1-02A 220 VAC A22L-Tj-T2-02M A22L-Tj-T2-02A 6 VDC A22L-Hj-6D-10M A22L-Hj-6D-10A 6 VAC A22L-Hj-6A-10M A22L-Hj-6A-10A 12 VAC/DC A22L-Hj-12A-10M A22L-Hj-12A-10A 24 VAC/DC A22L-Hj-24A-10M A22L-Hj-24A-10A 6 VDC A22L-Hj-6D-01M A22L-Hj-6D-01A 6 VAC A22L-Hj-6A-01M A22L-Hj-6A-01A 12 VAC/DC A22L-Hj-12A-01M A22L-Hj-12A-01A 24 VAC/DC A22L-Hj-24A-01M A22L-Hj-24A-01A 6 VDC A22L-Hj-6D-11M A22L-Hj-6D-11A 6 VAC A22L-Hj-6A-11M A22L-Hj-6A-11A 12 VAC/DC A22L-Hj-12A-11M A22L-Hj-12A-11A 24 VAC/DC A22L-Hj-24A-11M A22L-Hj-24A-11A 6 VAC LED lighting (Without transformer) 12 VAC/DC 24 VAC/DC SPST-NC 6 VDC 6 VAC 12 VAC/DC SPST-NO + SPST NC SPST-NC DPST-NO DPST-NC Round/Extended / type SPST-NO LED transformer lighting (With transformer) SPST-NC DPST-NC Round/Half-guard / g type SPST-NO LED lighting (Without transformer) SPST-NC SPST-NO + SPST NC SPST-NC (This table continues on the next page.) 5 A22 A22 Ordering Information Table -- continued from previous page Description Part number Appearance Contacts Rated voltage Illuminated operator color Momentary operation Latching operation Round/Half-guard / g type DPST-NO 6 VDC Insert one of the h following f ll i letters into the box j. A22L-Hj-6D-20M A22L-Hj-6D-20A A22L-Hj-6A-20M A22L-Hj-6A-20A A22L-Hj-12A-20M A22L-Hj-12A-20A R (red) Y (y (yellow)) G ((green)) W (white) A (blue) A22L-Hj-24A-20M A22L-Hj-24A-20A A22L-Hj-6D-02M A22L-Hj-6D-02A A22L-Hj-6A-02M A22L-Hj-6A-02A A22L-Hj-12A-02M A22L-Hj-12A-02A 24 VAC/DC A22L-Hj-24A-02M A22L-Hj-24A-02A 110 VAC A22L-Hj-T1-10M A22L-Hj-T1-10A 220 VAC A22L-Hj-T2-10M A22L-Hj-T2-10A 110 VAC A22L-Hj-T1-01M A22L-Hj-T1-01A 220 VAC A22L-Hj-T2-01M A22L-Hj-T2-01A SPST-NO + SPST NC SPST-NC 110 VAC A22L-Hj-T1-11M A22L-Hj-T1-11A 220 VAC A22L-Hj-T2-11M A22L-Hj-T2-11A DPST-NO 110 VAC A22L-Hj-T1-20M A22L-Hj-T1-20A 220 VAC A22L-Hj-T2-20M A22L-Hj-T2-20A 110 VAC A22L-Hj-T1-02M A22L-Hj-T1-02A 220 VAC A22L-Hj-T2-02M A22L-Hj-T2-02A 6 VDC A22L-Gj-6D-10M A22L-Gj-6D-10A 6 VAC A22L-Gj-6A-10M A22L-Gj-6A-10A 12 VAC/DC A22L-Gj-12A-10M A22L-Gj-12A-10A 24 VAC/DC A22L-Gj-24A-10M A22L-Gj-24A-10A 6 VDC A22L-Gj-6D-01M A22L-Gj-6D-01A 6 VAC A22L-Gj-6A-01M A22L-Gj-6A-01A 12 VAC/DC A22L-Gj-12A-01M A22L-Gj-12A-01A 24 VAC/DC A22L-Gj-24A-01M A22L-Gj-24A-01A 6 VDC A22L-Gj-6D-11M A22L-Gj-6D-11A 6 VAC A22L-Gj-6A-11M A22L-Gj-6A-11A 12 VAC/DC A22L-Gj-12A-11M A22L-Gj-12A-11A 24 VAC/DC A22L-Gj-24A-11M A22L-Gj-24A-11A 6 VDC A22L-Gj-6D-20M A22L-Gj-6D-20A 6 VAC A22L-Gj-6A-20M A22L-Gj-6A-20A 12 VAC/DC A22L-Gj-12A-20M A22L-Gj-12A-20A 24 VAC/DC A22L-Gj-24A-20M A22L-Gj-24A-20A 6 VDC A22L-Gj-6D-02M A22L-Gj-6D-02A 6 VAC A22L-Gj-6A-02M A22L-Gj-6A-02A 12 VAC/DC A22L-Gj-12A-02M A22L-Gj-12A-02A 24 VAC/DC A22L-Gj-24A-02M A22L-Gj-24A-02A 110 VAC A22L-Gj-T1-10M A22L-Gj-T1-10A 220 VAC A22L-Gj-T2-10M A22L-Gj-T2-10A 110 VAC A22L-Gj-T1-01M A22L-Gj-T1-01A 220 VAC A22L-Gj-T2-01M A22L-Gj-T2-01A SPST-NO + SPST NC SPST-NC 110 VAC A22L-Gj-T1-11M A22L-Gj-T1-11A 220 VAC A22L-Gj-T2-11M A22L-Gj-T2-11A DPST-NO 110 VAC A22L-Gj-T1-20M A22L-Gj-T1-20A 220 VAC A22L-Gj-T2-20M A22L-Gj-T2-20A 110 VAC A22L-Gj-T1-02M A22L-Gj-T1-02A 220 VAC A22L-Gj-T2-02M A22L-Gj-T2-02A 6 VAC LED lighting (Without transformer) 12 VAC/DC 24 VAC/DC DPST-NC 6 VDC 6 VAC 12 VAC/DC Round/Half-guard / g type SPST-NO LED lighting (With transformer) SPST-NC DPST-NC Round/Clear / f ll full-guard d type LED lighting (Without transformer) SPST-NO SPST-NC SPST-NO + SPST NC SPST-NC DPST-NO DPST-NC Round/Clear / f ll full-guard d type SPST-NO LED lighting li hti (With transformer) SPST-NC DPST-NC 6 A22 A22 Illuminated (Square Type) Description Part number Appearance Contacts Rated voltage Illuminated operator color Momentary operation Latching operation Square/Extended q / type SPST-NO 6 VDC Insert one of the h following f ll i letters into the box j. A22L-Cj-6D-10M A22L-Cj-6D-10A A22L-Cj-6A-10M A22L-Cj-6A-10A A22L-Cj-12A-10M A22L-Cj-12A-10A R (red) Y (y (yellow)) G ((green)) W (white) A (blue) A22L-Cj-24A-10M A22L-Cj-24A-10A A22L-Cj-6D-01M A22L-Cj-6D-01A A22L-Cj-6A-01M A22L-Cj-6A-01A A22L-Cj-12A-01M A22L-Cj-12A-01A 24 VAC/DC A22L-Cj-24A-01M A22L-Cj-24A-01A 6 VDC A22L-Cj-6D-11M A22L-Cj-6D-11A 6 VAC A22L-Cj-6A-11M A22L-Cj-6A-11A 12 VAC/DC A22L-Cj-12A-11M A22L-Cj-12A-11A 24 VAC/DC A22L-Cj-24A-11M A22L-Cj-24A-11A 6 VDC A22L-Cj-6D-20M A22L-Cj-6D-20A 6 VAC A22L-Cj-6A-20M A22L-Cj-6A-20A 12 VAC/DC A22L-Cj-12A-20M A22L-Cj-12A-20A 24 VAC/DC A22L-Cj-24A-20M A22L-Cj-24A-20A 6 VDC A22L-Cj-6D-02M A22L-Cj-6D-02A 6 VAC A22L-Cj-6A-02M A22L-Cj-6A-02A 12 VAC/DC A22L-Cj-12A-02M A22L-Cj-12A-02A 24 VAC/DC A22L-Cj-24A-02M A22L-Cj-24A-02A 110 VAC A22L-Cj-T1-10M A22L-Cj-T1-10A 220 VAC A22L-Cj-T2-10M A22L-Cj-T2-10A 110 VAC A22L-Cj-T1-01M A22L-Cj-T1-01A 220 VAC A22L-Cj-T2-01M A22L-Cj-T2-01A SPST-NO + SPST NC SPST-NC 110 VAC A22L-Cj-T1-11M A22L-Cj-T1-11A 220 VAC A22L-Cj-T2-11M A22L-Cj-T2-11A DPST-NO 110 VAC A22L-Cj-T1-20M A22L-Cj-T1-20A 220 VAC A22L-Cj-T2-20M A22L-Cj-T2-20A 110 VAC A22L-Cj-T1-02M A22L-Cj-T1-02A 220 VAC A22L-Cj-T2-02M A22L-Cj-T2-02A 6 VAC LED lighting (Without transformer) 12 VAC/DC 24 VAC/DC SPST-NC 6 VDC 6 VAC 12 VAC/DC SPST-NO + SPST NC SPST-NC DPST-NO DPST-NC Square/Extended q / type SPST-NO LED lighting (With transformer) SPST-NC DPST-NC (This table continues on the next page.) 7 A22 A22 Ordering Information Table -- continued from previous page Description Appearance Part number Contacts Rated voltage Illuminated operator color Momentary operation Latching operation 6 VDC Insert one of the h following f ll i letters into the box j. A22L-Dj-6D-10M A22L-Dj-6D-10A A22L-Dj-6A-10M A22L-Dj-6A-10A A22L-Dj-12A-10M A22L-Dj-12A-10A R (red) Y (y (yellow)) G ((green)) W (white) A (blue) A22L-Dj-24A-10M A22L-Dj-24A-10A A22L-Dj-6D-01M A22L-Dj-6D-01A A22L-Dj-6A-01M A22L-Dj-6A-01A A22L-Dj-12A-01M A22L-Dj-12A-01A 24 VAC/DC A22L-Dj-24A-01M A22L-Dj-24A-01A 6 VDC A22L-Dj-6D-11M A22L-Dj-6D-11A 6 VAC A22L-Dj-6A-11M A22L-Dj-6A-11A 12 VAC/DC A22L-Dj-12A-11M A22L-Dj-12A-11A 24 VAC/DC A22L-Dj-24A-11M A22L-Dj-24A-11A 6 VDC A22L-Dj-6D-20M A22L-Dj-6D-20A 6 VAC A22L-Dj-6A-20M A22L-Dj-6A-20A 12 VAC/DC A22L-Dj-12A-20M A22L-Dj-12A-20A 24 VAC/DC A22L-Dj-24A-20M A22L-Dj-24A-20A 6 VDC A22L-Dj-6D-02M A22L-Dj-6D-02A 6 VAC A22L-Dj-6A-02M A22L-Dj-6A-02A 12 VAC/DC A22L-Dj-12A-02M A22L-Dj-12A-02A 24 VAC/DC A22L-Dj-24A-02M A22L-Dj-24A-02A 110 VAC A22L-Dj-T1-10M A22L-Dj-T1-10A 220 VAC A22L-Dj-T2-10M A22L-Dj-T2-10A 110 VAC A22L-Dj-T1-01M A22L-Dj-T1-01A 220 VAC A22L-Dj-T2-01M A22L-Dj-T2-01A SPST-NO + SPST NC SPST-NC 110 VAC A22L-Dj-T1-11M A22L-Dj-T1-11A 220 VAC A22L-Dj-T2-11M A22L-Dj-T2-11A DPST-NO 110 VAC A22L-Dj-T1-20M A22L-Dj-T1-20A 220 VAC A22L-Dj-T2-20M A22L-Dj-T2-20A 110 VAC A22L-Dj-T1-02M A22L-Dj-T1-02A 220 VAC A22L-Dj-T2-02M A22L-Dj-T2-02A Square/Full-guard q / g type yp SPST-NO LED lighting (Without transformer) 6 VAC 12 VAC/DC 24 VAC/DC SPST-NC 6 VDC 6 VAC 12 VAC/DC SPST-NO + SPST NC SPST-NC DPST-NO DPST-NC Square/Full-guard q / g type yp SPST-NO LED lighting (Without transformer) SPST-NC DPST-NC 8 A22 A22 Dimensions Unit: mm (inch) Note: 1. The following illustrations are for momentary operation. 2. Latching operation models are 9.2 mm (0.36 in) longer. 3. Illuminated models have the same dimensions as shown below, whether they are with transformers or without transformers. J ILLUMINATED/NON-ILLUMINATED PUSHBUTTON SWITCHES Flush Type A22-F For SPST-NO (SPST-NC) Switches 36 (1.42) 29.7 dia. (1.17) 30 (1.18) 34 (1.34) 0.5 5.9 (0.23) 12 (0.47) Half-guard Type A22-H, A22L-H For DPST-NO (DPST-NC) Monoblock-contact Switches 44 (1.73) 29.7 dia. (1.17) 5.9 (0.23) 12 (0.47) 72.7 (2.86) (See note 2) 54.7 (2.15) (See note 2) Extended Type A22-T, A22L-T 18.5 (0.73) 29.7 dia. (1.17) 23.9 dia. (0.94) 34 (1.34) 29.7 dia. (1.17) 34 (1.34) 1.8 0.5 5.9 (0.23) 54.7 (2.15) (See note 2) 12 (0.47) Full-guard Type A22-G, A22L-G 19 (0.75) 54.7 (2.15) (See note 2) 40-dia. Mushroom Type A22-M 34 (1.34) 29.7 dia. (1.17) 5.9 (0.23) 34 (1.34) 40 dia. (1.57) 1.8 0.5 19 (0.75) 1.8 5.9 (0.23) 54.7 (2.15) (See note 2) 32 (1.26) Square/Extended Type A22-C, A22L-C 5.9 (0.23) 54.7 (2.15) (See note 2) Square Flush Type A22-D, A22L-D 29.8 x 29.8 (1.17 x 1.17) 29.8 x 29.8 (1.17 x 1.17) 34 (1.34) 25.6 x 25.6 (1.01 x 1.01) 12 (0.47) 34 (1.34) 1.8 1.8 5.9 (0.23) 18 (0.71) 5.9 (0.23) 19 (0.75) 54.7 (2.15) (See note 2) 9 54.7 (2.15) (See note 2) A22 A22 J TERMINAL ARRANGEMENT Terminal Arrangement (Bottom View) Non-illuminated (SPST-NO + SPST-NC) Illuminated (SPST-NO + SPST-NC) 20.7 (0.82) 10 (0.39) 16.7 (0.66) Non-illuminated (DPST-NO + DPST-NC) Contact Blocks 20.7 (0.82) 12 (0.47) 22 (0.87) 32 (1.26) Lamp Socket Contact Blocks Contact Blocks J TERMINAL CONNECTION Type Non-illuminated (SPST-NO + SPST-NC) J PANEL CUTOUT DIMENSIONS Terminal connection Bottom view 22.3+0.40 dia. Non-illuminated (DPST-NO + DPST-NC) Bottom view Illuminated without transformer (SPST-NO + SPST-NC) Bottom view Illuminated with transformer (SPST-NO + SPST-NC) Bottom view 25 +0.50 dia. Note: When applying a coating such as paint to a panel, the dimensions should be those after the application of the coating. A lock fitting is provided as a standard item. Note: For additional specifications and information refer to the Common to all assemblies section at the end of this publication. 10 Complete Assemblies A22S/W Knob-type Selector Switch Install in 22-mm dia. or 25-mm dia. Panel Cutout H Illuminated and Non-illuminated models H Locking lever ensures easy mounting and removal of switch unit H Increase wiring efficiency and decrease mounting depth with three-row mounting of switch unit contact blocks H Finger-safe contact blocks H Use optional 25-mm dia. ring to install in 25-mm dia. panel cutouts c H IP65 This product was manufactured at OMRON Izumo. OMRON Izumo has obtained approvals from international certification bodies for its quality system and environmental control system. Ordering Information J CONSTRUCTION Operational Unit Number of Positions: 2 Positions/3 Positions Applicable Colors Lock Fitting Non-illuminated: Black Illuminated: Red, green, yellow, blue Lamp * Light Source LED Lamp Incandescent Lamp Switch Unit * Contacts SPST-NO, SPST-NC, SPST-NO + SPST-NC, DPST-NO, DPST-NC * Lighting Method Non-illuminated Illuminated (without transformer) Illuminated (with transformer) 11 A22S/W A22S/W J PART NUMBER LEGEND Shipped as a set which includes the Operational Unit, LED (Illuminated Type only), and Switch Unit. 1 2 3 4 5 A22j-jj-j-j 1 Illuminated/Non-illuminated 3 Operator Color Code Description Code S Non-illuminated W Illuminated 5 Contacts Code Description None Non-illuminated 10 SPST-NO (*) R Red 01 SPST-NC (*) G Green 11 SPST-NO + SPST-NC Y Yellow 20 DPST-NO A Blue 02 Description Note: 2 Number of Positions/Reset Method Code Description 2M 2 Positions/Maintained 2A 2 Positions/Spring return 3M 3 Positions/Maintained 3A 3 Positions/Spring return C2M 2 Positions/Maintained extended lever C2A 2 Positions/Spring return extended lever C3M 3 Positions/Maintained extended lever C3A 3 Positions/Spring return extended lever 4 Light Source DPST-NC * for models with 2 Positions only Note: SPST= Single Pole, Single Throw DPST= Double Pole, Single Throw Without transformer Code Rated Voltage None Non-illuminated 6D LED 6 VDC 6A 6 VAC 12A 12 VAC/DC 24A 24 VAC/DC With transformer None Non-illuminated T1 LED 110 VAC*1 220 VAC*2 T2 *1) Operational voltage: 95 to 115 VAC *2) Operational voltage: 190 to 230 VAC Note: With transformer types, the LED lamp (24 VAC/DC) can be lit by directly applying 110 VAC/DC (220 VAC/DC) to the lamp terminal. The LED is a 24-VAC/DC type. (Actual color of yellow selector switches more closely resembles amber than true yellow.) 12 A22S/W A22S/W J KNOB-TYPE SELECTOR SWITCH Non-illuminated Appearance Positions Operating method Contacts Operator color Part number Knob-type yp selector switch 2 positions p Maintained SPST-NO Black A22S-2M-10 Spring p g return 3 positions p Maintained Spring p g return SPST-NC A22S-2M-01 SPST-NO + SPST-NC A22S-2M-11 DPST-NO A22S-2M-20 DPST-NC A22S-2M-02 SPST-NO A22S-2A-10 SPST-NC A22S-2A-01 SPST-NO + SPST-NC A22S-2A-11 DPST-NO A22S-2A-20 DPST-NC A22S-2A-02 SPST-NO + SPST-NC A22S-3M-11 DPST-NO A22S-3M-20 DPST-NC A22S-3M-02 SPST-NO + SPST-NC A22S-3A-11 DPST-NO A22S-3A-20 DPST-NC Extended lever knob-type yp selector l switch i h 2 positions p Maintained Spring p g return 3 positions p Maintained Spring p g return SPST-NO A22S-3A-02 Black A22S-C2M-10 SPST-NC A22S-C2M-01 SPST-NO + SPST-NC A22S-C2M-11 DPST-NO A22S-C2M-20 DPST-NC A22S-C2M-02 SPST-NO A22S-C2A-10 SPST-NC A22S-C2A-01 SPST-NO + SPST-NC A22S-C2A-11 DPST-NO A22S-C2A-20 DPST-NC A22S-C2A-02 SPST-NO + SPST-NC A22S-C3M-11 DPST-NO A22S-C3M-20 DPST-NC A22S-C3M-02 SPST-NO + SPST-NC A22S-C3A-11 DPST-NO A22S-C3A-20 DPST-NC A22S-C3A-02 13 A22S/W A22S/W Illuminated (Without Transformer) Appearance Positions Operating method Contacts Rated voltage Operator color Part number Knob-type yp selector switch 2 positions p Maintained SPST-NO 6 VDC Insert one of the h following f ll i letters into the box j. A22W-2Mj-6D-10 R (red) Y (y (yellow)) G ((green)) A (blue) A22W-2Mj-24A-10 6 VAC LED lighting (without transformer) 12 VAC/DC 24 VAC/DC SPST-NC 6 VDC 6 VAC 12 VAC/DC SPST-NO + SPST NC SPST-NC DPST-NO DPST-NC Spring p g return SPST-NO SPST-NC SPST-NO + SPST NC SPST-NC DPST-NO DPST-NC A22W-2Mj-12A-10 A22W-2Mj-6D-01 A22W-2Mj-6A-01 A22W-2Mj-12A-01 24 VAC/DC A22W-2Mj-24A-01 6 VDC A22W-2Mj-6D-11 6 VAC A22W-2Mj-6A-11 12 VAC/DC A22W-2Mj-12A-11 24 VAC/DC A22W-2Mj-24A-11 6 VDC A22W-2Mj-6D-20 6 VAC A22W-2Mj-6A-20 12 VAC/DC A22W-2Mj-12A-20 24 VAC/DC A22W-2Mj-24A-20 6 VDC A22W-2Mj-6D-02 6 VAC A22W-2Mj-6A-02 12 VAC/DC A22W-2Mj-12A-02 24 VAC/DC A22W-2Mj-24A-02 6 VDC A22W-2Aj-6D-10 6 VAC A22W-2Aj-6A-10 12 VAC/DC A22W-2Aj-12A-10 24 VAC/DC A22W-2Aj-24A-10 6 VDC A22W-2Aj-6D-01 6 VAC A22W-2Aj-6A-01 12 VAC/DC A22W-2Aj-12A-01 24 VAC/DC A22W-2Aj-24A-01 6 VDC A22W-2Aj-6D-11 6 VAC A22W-2Aj-6A-11 12 VAC/DC A22W-2Aj-12A-11 24 VAC/DC A22W-2Aj-24A-11 6 VDC A22W-2Aj-6D-20 6 VAC A22W-2Aj-6A-20 12 VAC/DC A22W-2Aj-12A-20 24 VAC/DC A22W-2Aj-24A-20 6 VDC A22W-2Aj-6D-02 6 VAC A22W-2Aj-6A-02 12 VAC/DC A22W-2Aj-12A-02 24 VAC/DC A22W-2Aj-24A-02 (This table continues on the next page.) 14 A22W-2Mj-6A-10 A22S/W A22S/W Ordering Information Table -- continued from previous page Appearance Positions Operating method Contacts Rated voltage Operator color Part number Knob-type yp selector switch 3 positions p Maintained SPST-NO + SPST NC SPST-NC 6 VDC Insert one of the h following f ll i letters into the box j. A22W-3Mj-6D-11 R (red) Y (y (yellow)) G ((green)) A (blue) A22W-3Mj-24A-11 LED lighting (without transformer) 6 VAC 12 VAC/DC 24 VAC/DC DPST-NO 6 VDC 6 VAC 12 VAC/DC DPST-NC LED lighting (without transformer) 3 positions p Spring p g return SPST-NO + SPST NC SPST-NC A22W-3Mj-12A-20 A22W-3Mj-6D-02 6 VAC A22W-3Mj-6A-02 12 VAC/DC A22W-3Mj-12A-02 6 VDC 6 VAC 6 VDC 6 VAC 12 VAC/DC 15 A22W-3Mj-6A-20 A22W-3Mj-24A-20 24 VAC/DC DPST-NC A22W-3Mj-6D-20 6 VDC 12 VAC/DC DPST-NO A22W-3Mj-12A-11 24 VAC/DC 24 VAC/DC Knob-type yp selector switch A22W-3Mj-6A-11 A22W-3Mj-24A-02 Insert one of the h following f ll i letters into the box j. A22W-3Aj-6D-11 R (red) Y (y (yellow)) G ((green)) A (blue) A22W-3Aj-24A-11 A22W-3Aj-6A-11 A22W-3Aj-12A-11 A22W-3Aj-6D-20 A22W-3Aj-6A-20 A22W-3Aj-12A-20 24 VAC/DC A22W-3Aj-24A-20 6 VDC A22W-3Aj-6D-02 6 VAC A22W-3Aj-6A-02 12 VAC/DC A22W-3Aj-12A-02 24 VAC/DC A22W-3Aj-24A-02 A22S/W A22S/W Illuminated (With Transformer) Appearance Positions Operating method Contacts Rated voltage Operator color Part number Knob-type yp selector switch 2 positions p Maintained SPST-NO 110 VAC Insert one of the h following f ll i letters into the box j. A22W-2Mj-T1-10 R (red) Y (y (yellow)) G ((green)) A (blue) A22W-2Mj-T2-01 220 VAC LED lighting (with transformer) SPST-NC 110 VAC 220 VAC SPST-NO + SPST NC SPST-NC 110 VAC DPST-NO 110 VAC A22W-2Mj-T1-20 A22W-2Mj-T1-02 220 VAC A22W-2Mj-T2-02 110 VAC A22W-2Aj-T1-10 220 VAC A22W-2Aj-T2-10 110 VAC A22W-2Aj-T1-01 220 VAC A22W-2Aj-T2-01 SPST-NO + SPST NC SPST-NC 110 VAC A22W-2Aj-T1-11 220 VAC A22W-2Aj-T2-11 DPST-NO 110 VAC A22W-2Aj-T1-20 220 VAC A22W-2Aj-T2-20 110 VAC A22W-2Aj-T1-02 220 VAC A22W-2Aj-T2-02 SPST-NO + SPST NC SPST-NC 110 VAC A22W-3Mj-T1-11 220 VAC A22W-3Mj-T2-11 DPST-NO 110 VAC A22W-3Mj-T1-20 220 VAC A22W-3Mj-T2-20 110 VAC A22W-3Mj-T1-02 SPST-NO DPST-NC Spring p g return A22W-2Mj-T2-11 110 VAC DPST-NC Maintained A22W-2Mj-T1-11 A22W-2Mj-T2-20 SPST-NC 3 positions p A22W-2Mj-T1-01 220 VAC DPST-NC Spring p g return 220 VAC A22W-2Mj-T2-10 220 VAC A22W-3Mj-T2-02 SPST-NO + SPST NC SPST-NC 110 VAC A22W-3Aj-T1-11 220 VAC A22W-3Aj-T2-11 DPST-NO 110 VAC A22W-3Aj-T1-20 220 VAC A22W-3Aj-T2-20 110 VAC A22W-3Aj-T1-02 220 VAC A22W-3Aj-T2-02 DPST-NC 16 A22S/W A22S/W Dimensions Unit: mm (inch) J KNOB-TYPE SELECTOR SWITCH (ILLUMINATED/NON-ILLUMINATED) A22S-S 34 (1.34) 30 dia (1.18) 1.8 5.8 (0.23) 54.7 (2.15) 12 26.2 (0.47) (1.03) A22S-C3 29 dia. (1.14) 30 dia (1.18) 39 (1.53) 26.2 (1.03) 0.5 1.8 12 M22 P = 1 5.9 13.5 22 (0.87) 29 (1.14) A22S-C2 30 dia (1.18) 29 dia. (1.14) 29 (1.14) 26.2 (1.03) 0.5 1.8 12 5.9 13.5 22 (0.87) 17 39 (1.53) A22S/W A22S/W J TERMINAL ARRANGEMENT J TERMINAL CONNECTION Terminal Arrangement (Bottom View) Non-illuminated (SPST-NO + SPST-NC) Type Illuminated (SPST-NO + SPST-NC) 20.7 (0.82) 10 (0.40) Bottom view Illuminated without transformer Bottom view Illuminated with transformer Bottom view Contact Blocks 16.7 (0.66) 22 (0.87) Lamp Socket Contact Blocks Connection diagram Non-illuminated J PANEL CUTOUT DIMENSIONS Note: The above terminal connection diagrams are examples for SPST-NO + SPST-NC. 22.3+0.40 dia. 25 +0.50 dia. Note: When applying a coating such as paint to a panel, the dimensions should be those after the application of the coating. A lock fitting is provided as a standard item. J CONTACT CONFIGURATION 2-Position Type Knob position SPST-NO SPST-NC SPST-NO + SPST-NC DPST-NO DPST-NC 3-Position Type Knob position SPST-NO + SPST-NC DPST-NO DPST-NC Note: For additional specifications and information refer to the Common to all assemblies section at the end of this publication. 18 Complete Assemblies A22K Key-Type Selector Switch Install in 22-mm dia. or 25-mm dia. Panel Cutout H Locking lever ensures easy mounting and removal of switch unit H Increase wiring efficiency and decrease mounting depth with three-row mounting of switch unit contact blocks H Finger-safe contacts H Use optional 25-mm dia. ring to install in 25-mm dia. panel cutouts c H Install using either round, forked crimp terminals, or ferrules H IP65 oil resistant: EN60947-5-1 This product was manufactured at OMRON Izumo. OMRON Izumo has obtained approvals from international certification bodies for its quality system and environmental control system. Ordering Information J CONSTRUCTION Operational Unit Number of Positions * 2 Positions/3 Positions Key Release Position 2 Positions Lock Fitting 3 Positions Switch Unit * Contacts SPST-NO, SPST-NC, SPST-NO + SPST-NC, DPST-NO, DPST-NC 19 A22K A22K J PART NUMBER LEGEND Shipped as a set which includes the Operational Unit and Switch Unit with contact blocks. 1 2 A22K-j-j 1 Number of Positions/Reset Method Code 2ML Positions Reset method 2 positions Maintained 2M 2AL 3ML Spring return 3 positions Maintained 3M 3MC 3AC Spring return 2 Contacts Key release position Code Description 10 SPST-NO (*) Left 01 SPST-NC (*) Left and right 11 SPST-NO + SPST-NC Left 20 DPST-NO 02 DPST-NC Left Left and right Note: Center Note: SPST= Single Pole, Single Throw DPST= Double Pole, Single Throw Center 20 * for models with 2 Positions A22K A22K J KEY-TYPE SELECTOR SWITCH Appearance Positions Operator type Contacts Key-type selector switch 2 positions Maintained SPST-NO Key release position Color of Operational Unit Part number Black A22K-2ML-10 A22K-2M-10 SPST-NC A22K-2ML-01 A22K-2M-01 SPST-NO + SPST-NC SPST NC A22K-2ML-11 A22K-2M-11 DPST-NO A22K-2ML-20 A22K-2M-20 DPST-NC A22K-2ML-02 A22K-2M-02 Spring p g return 3 positions Maintained SPST-NO A22K-2AL-10 SPST-NC SPST-NO + SPST-NC A22K-2AL-01 DPST-NO A22K-2AL-20 DPST-NC A22K-2AL-02 SPST-NO + SPST-NC S S C A22K-3ML-11 A22K-2AL-11 A22K-3M-11 A22K-3MC-11 DPST-NO A22K-3ML-20 A22K-3M-20 A22K-3MC-20 DPST-NC A22K-3ML-02 A22K-3M-02 A22K-3MC-02 Spring return SPST-NO + SPST-NC A22K-3AC-11 DPST-NO A22K-3AC-20 DPST-NC A22K-3AC-02 21 A22K A22K Dimensions Unit: mm (inch) J KEY-TYPE SELECTOR SWITCH A22K 34 (1.34) 30 dia. (1.18) 25.5 (1.00) 23.7 (0.93) 12 (0.47) 54.7 (2.15) J TERMINAL ARRANGEMENT J TERMINAL CONNECTION Terminal Arrangement (Bottom View) Type Non-illuminated (SPST-NO + SPST-NC) Non-illuminated Terminal connection Bottom view 20.7 (0.81) Note: The above terminal connection diagrams are examples for SPST-NO + SPST-NC. 16.7 (0.66) Switch Unit J PANEL CUTOUT DIMENSIONS 22.3+0.40 dia. 25 +0.50 dia. Note: When applying a coating such as paint to a panel, the dimensions should be those after the application of the coating. A lock fitting is provided as a standard item. 22 A22K A22K J CONTACT CONFIGURATION 2-Position Type Knob position SPST-NO SPST-NC SPST-NO + SPST-NC DPST-NO DPST-NC 3-Position Type Knob position SPST-NO + SPST-NC DPST-NO DPST-NC Note: For additional specifications and information refer to the Common to all assemblies section at the end of this publication. 23 Complete Assemblies M22 Pilot Lights -- 22 mm 22-mm dia. and 25-mm dia. Round and Square Indicators H Locking lever ensures easy mounting and removal of switch unit H Use optional 25-mm dia. ring to install in 25-mm dia. panel cutouts H Finger protection mechanism on Lamp Unit provided as a standard feature H IP65 oil resistant: EN60947-5-1 c This product was manufactured at OMRON Izumo. OMRON Izumo has obtained approvals from international certification bodies for its quality system and environmental control system. Ordering Information J CONSTRUCTION Indicator Unit Available Colors Red, green, yellow, white, blue Lock Fitting Lamp * Light source LED Lamp Incandescent Lamp Lamp Socket * Lighting Method Illuminated (without transformer) Illuminated (with transformer) (Actual color of yellow pushbuttons more closely resembles amber than true yellow.) 24 M22 M22 J PART NUMBER LEGEND Shipped as a set which includes the Operational Unit, LED, and Lamp Socket. 1 2 3 M22-jj-j 1 Flange Shape 2 Illumination Color 3 Light Source Code Description Code Description F Round/Flush R Red Code Operating voltage C Square/Extended G Green 6D LED Y Yellow 6A 6 VAC W White 12A 12 VAC/DC A Blue 24A 24 VAC/DC Without transformer 6 VDC With transformer T1 Note: With the transformer types, LED lamp (24 VAC/DC) can be lit by directly applying 110 VAC/DC (220 VAC/DC) to the lamp terminal. The LED is 24-VAC/DC type. LED T2 110 VAC 220 VAC (Actual color of yellow pushbuttons more closely resembles amber than true yellow.) J M22 INDICATOR Appearance Lighting Rated voltage Operator color Part number Round/Flush / Wi h Without transformer f LED 6 VDC Insert one of the f ll i lletters following into the box j. j M22-Fj-6D 6 VAC 12 VAC/DC 24 VAC/DC Round/Flush With transformer LED 110 VAC 220 VAC Square/Extended q / Wi h Without transformer f Square/Extended With transformer LED LED R (red) Y (yellow) G (green) W (white) A (blue M22-Fj-6A M22-Fj-12A M22-Fj-24A M22-Fj-T1 M22-Fj-T2 6 VDC M22-Cj-6D 6 VAC M22-Cj-6A 12 VAC/DC M22-Cj-12A 24 VAC/DC M22-Cj-24A 110 VAC M22-Cj-T1 220 VAC M22-Cj-T2 Note: To order Incandescent versions of the M22 Pilot Light, replace the last two digits in the part number (ie, 12A, 24A, T1) with the appropriate code from table 3 of the Part Number Legend at the top of the page. Example: M22-FR-24 is a red, round indicator with 24 VAC incandescent light source. 25 M22 M22 Specifications J RATINGS LED Lamp Rated voltage Rated current Operating voltage 6 VDC 60 mA 6 VDC5% 6 VAC/DC 60 mA 6 VAC/DC5% 12 VAC/DC 30 mA 12 VAC/DC5% 24 VAC/DC 15 mA 24 VAC/DC5% Rated voltage Operational voltage Applicable lamp (BA9S/13j gold) 110 VAC 95 to 115 VAC LED Lamp p ((A22-24j) j) 220 VAC 190 to 230 VAC Transformer Lighting J APPROVED STANDARDS Recognized organization Standards File No. UL, cUL (See note) UL508 E41515 ASTA EN60947-5-1 -- Note: UL: CSA C22 No. 14 Dimensions Unit: mm (inch) J INDICATORS Flush M22-F Square M22-C 34 (1.34) 29.7 dia. (1.17) 34 (1.34) 25.6 x 25.6 (1.01 x 1.01) 29.8 x 29.8 (1.17 x 1.17) 1.8 5.9 (0.23) 5.9 (0.23) 16 (0.63) 18 (0.71) 54.7 (2.15) 26 54.7 (2.15) M22 M22 J TERMINAL ARRANGEMENT J TERMINAL CONNECTION Terminal Arrangement (Bottom View) Without transformer/With transformer Without transformer With transformer Bottom view Top view 22 (0.87) Lamp Socket J PANEL CUTOUT DIMENSIONS +0.4 22.3 0 dia. (0.88 +0.02 ) 0 +0.5 25 0 dia. (0.98 +0.02 0 ) Note: When applying a coating such as paint to a panel, the dimensions should be those after the application of the coating. A lock fitting is provided as a standard item. Note: For additional specifications and information refer to the Common to all assemblies section at the end of this publication. 27 Common To all Assemblies Common To All Assemblies Specifications J APPROVED STANDARDS Recognized organization Standards File No. UL, cUL (See note) UL508 E41515 ASTA EN60947-5-1 -- Note: UL: CSA C22 No. 14 J RATINGS Contacts (General-purpose Load) Rated carry y current 10 amps p Rated voltage l Rated current (A) Utilization category AC15 (inductive load) AC12 (resistive load) DC13 (inductive load) DC12 (resistive load) 24 VAC 10 10 -- -- 110 VAC 5 10 220 VAC 3 6 380 VAC 2 3 440 VAC 1 2 24 VDC -- -- 1.5 10 110 VDC 0.5 2 220 VDC 0.2 0.6 380 VDC 0.1 0.2 Note: 1. Rated current values are determined according to the testing conditions specified by JIS C4520. The above ratings were obtained by conducting tests under the following conditions as specified by JIS C4505. (1) Ambient temperature: 202C (2) Ambient humidity: 655% (3) Operating frequency: 20 operations/min 2. Minimum applied load: 10 mA, 5 VDC Contacts (Microload) Rated applied load Minimum applied load 50 mA, 5 VDC (Resistive load) 1 mA, 5 VDC LED Indicators without Transformer Rated voltage Rated current Operating voltage 6 VDC 60 mA 6 VDC5% 6 VAC 60 mA 6 VAC/DC5% 12 VAC/DC 30 mA 12 VAC/DC5% 24 VAC/DC 15 mA 24 VAC/DC5% Rated voltage Operational voltage Applicable lamp (BA8S/13j gold) 110 VAC 95 to 115 VAC LED Lamp p ((A22-24Aj) j) 220 VAC 190 to 230 VAC Transformer Lighting 28 Common To All Assemblies Common To All Assemblies J CHARACTERISTICS Item Allowable operating f frequency Pushbutton switches Emergency stop switches Knob-type selector switches Key-type selector switch Non-illuminated models: A22-F, A22-T, A22-G, A22-S, A22-C, A22-D, A22-H, A22-M Non-illuminated models: A22E Non-illuminated models: A22S Non-illuminated models: A22K Illuminated models: A22L-T, A22L-G, A22L-H, A22L-D, A22L-C Mechanical Momentary operation: 60 operations/min max. Electrical 30 operations/min max. Illuminated models: A22EL 30 operations/min max. Illuminated models: A22W Manual release: 30 operations/min max. Automatic release: 30 operations/min max. 30 operations/min max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min between terminals of same polarity 2,500 VAC, 50/60 Hz for 1 min between terminals of different polarity and also between each terminal and ground Vibration resistance (See note 2) Malfunction: 10 to 55 Hz, 1.5-mm double amplitude (malfunction within 1 ms) Shock resistance es sta ce Mechanical 1,000 m/s2 {100G} 1,000 m/s2 {100G} 1,000 m/s2 {100G} 1,000 m/s2 {100G} 1,000 m/s2 {100G} 1,000 m/s2 {100G} Malfunction (See note 2) 1,000 m/s2 {100G} max. 600 m/s2 {60G} max. 250 m/s2 {25G} max. 1,000 m/s2 {100G} max. 600 m/s2 {60G} max. 1,000 m/s2 {100G} max. Mechanical Momentary operation: 5,000,000 operations min. Momentary operation: 300,000 operations min. 500,000 operations min. 100,000 operations min. 500,000 operations min. Electrical 500,000 operations min. 300,000 operations min. 300,000 operations min. 500,000 operations min. 100,000 operations min. 500,000 operations min. Ambient temperature (See note 1 ) Operating: -20C to 70C (-4F to 158F) Storage: -40C to 70C (-40F to 158F) Operating: -20C to 70C (-4F to 158F) Storage: -40C to 70C (-40F to 158F) Operating: -20C to 55C (-4F to 131F) Storage: -40C to 70C (-40F to 158F) Operating: -20C to 70C (-4F to 158F) Storage: -40C to 70C (-40F to 158F) Operating: -20C to 55C (-4F to 131F) Storage: -40C to 70C (-40F to 158F) Operating: -20C to 70C (-4F to 158F) Storage: -40C to 70C (-40F to 158F) Ambient humidity Operating: 35% to 85% Degree of protection IP65 Electric shock protection class Class II Degree of contamination 3 (IEC947-5-1) Life expectancy Operating: -20C to 55C (-4F to 131F) Storage: -40C to 70C (-40F to 158F) Note: 1. With no icing or condensation. 2. Malfunction within 1 ms. 29 Common To All Assemblies Common To All Assemblies J OPERATING CHARACTERISTICS (FOR SPST-NO/SPST-NC) Item Total travel force (TTF) max. Pushbutton switches Emergency stop switches Knob-type selector switch Key-type selector switch Illuminated Non-illuminated Pushbutton Switches Push-lock turn-reset system Manual release Automatic release Manual release A22-F, A22-G, A22-C, A22-S, A22-T, A22-H, A22-D, A22-M, A22L-T, A22L-H, A22L-D, A22L-G, A22L-C A22E A22S, A22W A22S, A22W A22K 29.4 N {3.0 kgf} 44.1 N {4.5 kgf} 0.34 N S m {3.5 kgf S cm} (See note) 0.25 N S m {2.5 kgf S cm} for two position (See note) 0.34 N {3.5 gf} (See note) 0.34 N S m {3.5 kgf S cm} for three position Automatic release 0.25 N S m {2.5 kgf S cm} for three position (See note) 0.34 N S m {3.5 kgf S cm} for three position Total travel (TT) 5.5 mm max. 101 mm Approx. 90 for two position (Approx. 45 for three position) Approx. 90 for two position Releasing force (RF) min. -- 0.25 N S m max. {2.5 kgf S cm} (See note) 0.34 N S m max. {3.5 kgf S cm} (See note) 0.34 N S m max. {3.5 kgf S cm} (See note) -- -- Note: Rotation torque for Emergency Stop Pushbutton, Knob-type Selector, and Key-type Selector Switches. Accessories (Order Separately) Item Appearance Contact Blocks Classification SPST-NO General-purpose load Microload SPST-NC DPST-NO DPST-NC Remarks Part number Provided as standard. Order Contact Co tact Blocks oc s only o y when e adding or replacing them. A22-10 A22-01 Microload A22-01S General-purpose load A22-20 Microload A22-20S General-purpose load A22-02 Microload Lamp p Sockets Direct lighting Transformer ill i ti illumination A22-10S General-purpose load 110 VAC A22-02S Used when changing g g the lightg i method. ing th d 220 VAC A22-TN A22-T1 A22-T2 Mounting Latches For momentary models Provided as standard. Order Mounting Latches only when mounting Contact Blocks or Lamp Sockets that are purchased individually. A22-3200 Legend g plate l frames With Snap-in p L Legend d Plate Pl (Without text) Snap-in p Legend g Plate is acrylic. y A22Z-3321 Standard size i Large g size i White Red A22Z-3322 Black A22Z-3323 Without Snap-in Legend Plate A22Z-3320 With Snap-in p L Legend d Plate Pl (Without text) White A22Z-3331 Red A22Z-3332 Black A22Z-3333 Without Snap-in Legend Plate (This table continues on the next page.) 30 A22Z-3330 Common To All Assemblies Common To All Assemblies (continued from previous page) Item Classification Remarks Part number Lock fitting Appearance Round The body is equipped with a Lock Fitting. This Lock Fitting is used when a more secure lock feature is required. A22Z-3360 Metallic bezel rings For flush or projection models Replace with the standard model. Material: nickel-plated zinc A22Z-3580 Used to prevent dust or water from entering the Operational Unit. Color: opaque Material: silicon A22Z-3600F Used for changing g g the Operap tional i l Unit U i color l off the h PushbutP hb ton Switch. Switch A22Z-30TR For full-guard models Sealing caps For flush models For extended models For full-guard models Color lenses Red Green Yellow White A22Z-3582 A22Z-3600T A22Z-3600G A22Z-30TG A22Z-30TY A22Z-30TW Blue A22Z-30TA Three-throw spacers For Pushbutton Switches Used when mounting three NonIlluminated Switch Units. Cannot be used with Illuminated Emergency Stop Switches. A22Z-3003 Hole plug Round Can be plugged into pre-cut panel holes for future expansion. The color is black. A22Z-3550 25 mm-dia. ring 25 mm ring Can be fit into a 25 mm-dia. hole in the panel. Since this is not attached to the main body, order separately. A22Z-R25 Snap-in p l legend d plates Without text Attached to the Standard-size L Legend d Plate Pl Frame. F A22Z-3443B Material: Acrylic A22Z-3443W Standard size i Black Red White Transparent A22Z-3443C White text on red backback ground f A22Z-3443R-2 STOP A22Z-3443R-4 White text on bl k backblack b k ground | A22Z-3443B-1 START A22Z-3443B-3 ON A22Z-3443B-5 OFF A22Z-3443B-6 UP A22Z-3443B-7 DOWN A22Z-3443B-8 POWER ON A22Z-3443B-9 OFF-ON Large g size i Without text Black Red White A22Z-3443B-10 Attached to the Large-size g Legg end d Plate Pl Frame F A22Z-3453B Material: Acrylic A22Z-3453W Transparent For Emergencyy g St Stop Switch A22Z-3443R 60-dia. round plate with black letters on a yellow background 90-dia. round plate with black letters on a yellow background (This table continues on the next page.) 31 A22Z-3453R A22Z-3453C "EMERGENCY STOP" is engraved on the plate. Used as an Emergency g y Stop p Switch L Legend d Plate. Pl t A22Z-3466-1 A22Z-3476-1 Common To All Assemblies Common To All Assemblies (continued from previous page) Item Appearance Character films Classification Remarks Part number No print (Round) After printing p g on a film,, affix to the h indicator i di plate l off the h IllumiIll i nated Pushbutton Switch. Switch (The back is coated with adhesive.) A22Z-3460 Character print i (Round) (R d) | f A22Z-3460-1 A22Z-3460-2 START A22Z-3460-3 STOP A22Z-3460-4 No print (Square) A22Z-3480 Lamp extractor -- Rubber tool used to easily replace Lamps. A22Z-3901 Tightening wrench -- Tool used to tighten nuts from the back of the panel. A22Z-3905 Lens tightening tool -- Used for replacing the cap of the Half-guard Pushbutton Switch. A22Z-3908 Lens puller -- Used for removing the lens from the indicator of the Square Illuminated Pushbutton Switch. A3PJ-5080 J ENCLOSURES Material Hole size Number of holes Part number Polyester y 22.5 mm (0.88 ( in)) 1 A22N-PENC-1 2 A22N-PENC-2 3 A22N-PENC-3 1 A22N-MENC-1 2 A22N-MENC-2 3 A22N-MENC-3 4 A22N-MENC-4 6 A22N-MENC-6 9 A22N-MENC-9 12 A22N-MENC-12 16 A22N-MENC-16 Metallic 22.5 mm (0.88 ( in)) Note: For more information on pushbutton enclosures refer to drawings in the Dimensions section. 32 Common To All Assemblies Common To All Assemblies J NAMEPLATE NOMENCLATURE 1 2 3 A22N-jjj Code Material Code P Plastic X Shield M Metal R Rectangular S Square A22N-PRj Note: To complete the part number of the standard nameplates, select the plate type and add the number from the table below. Example: Plastic Square Nameplate engraved "Reset" A22N-PS38 Shape A22N-PSj A22N-PXj A22N-MRj A22N-PE 1 AUTO 30 ON 106 HIGH-LOW 150 AUTO-MANOFF 175 START-JOG-STOP 2 CLOSE 31 OPEN 107 INCH-REVERSE 151 AUTO-OFF-HAND 176 START-RUN-STOP 3 CYCLE START 32 OUT 108 JOG-FOR 152 AUTO-OFF-MAN 177 UP-OFF-DOWN 4 CYCLE STOP 33 POWER ON 109 JOG-REV 153 CLOSE-OFF-OPEN 178 1-OFF-2 5 DECREASE 34 PULL TO START 110 JOG-RUN 154 DOWN-OFF-SLOW 179 HAND-OFF-AUTO 6 DOWN 35 PUSH TO TEST 111 LEFT-RUN 155 FAST-OFF-SLOW 180 7 EMERG.STOP (red) 36 PUSH TO STOP 112 LOWER-RAISE 156 FOR-OFF-REV 181 8 FAST 37 RAISE 113 MAN-AUTO 157 FOR-STOP-REV 182 9 FAULT 38 RESET 114 OFF-ON 158 HIGH-LOW-OFF 183 10 FEED 39 REVERSE 115 ON-OFF 159 HIGH-OFF-LOW 184 11 FEED START 40 RIGHT 116 OPEN-CLOSE 160 JOG-SAFE-RUN 185 12 FEED STOP 41 RUN 117 RAISE-LOWER 161 JOG-STOP-RUN 186 13 FLUID LEVEL LOW 42 SLOW 118 REV-FOR 162 LEFT-OFF-RIGHT 187 I-II-III 14 FORWARD 43 SPEED 119 RUN-INCH 163 LOC-OFF-REMOTE 188 III 15 FULL SPEED 44 START 120 RUN-JOG 164 LOW-OFF-HIGH 190 60 MM E-STOP 16 HAND 45 STOP 121 RUN-SAFE 165 LOWEROFF-RAISE 191 90 MM E-STOP 17 HIGH 46 TEST 122 SAFE-RUN 166 OFF COOLANT ON 200 BLANK NAMEPLATE 18 IN 47 UP 123 SLOW-FAST 167 OFF-LOC-REMOTE 200E SPECIAL ENGRAVING 19 INCH 48 1ST SPEED 124 START-JOG 168 OFF-MAN-AUTO 20 INCREASE 49 2ND SPEED 125 START-STOP 169 OFF-SLOW-FAST 21 JOG 50 3RD SPEED 126 STOP-START 170 OFF-1-2 22 JOG FORWARD 51 4TH SPEED 127 SUMMER-WINTER 171 OPEN-OFF-CLOSE 23 LEFT 100 AUTO-MAN 128 UP-DOWN 172 RAISE-OFFLOWER 24 LOW 101 CLOSE-OPEN 173 SLOW-OFF-FAST 25 LOW SPEED 102 DOWN-UP 174 SLOW-OFF-START 26 LOWER 103 FAST-SLOW 27 MOTOR RUN 104 FOR-REV 28 MOTOR STOP 105 HAND-AUTO 29 OFF Note: All plastic name plates are adhesive backed, contain beveled edges and are supplied standard with white lettering on black background. Any deviation from items listed here will be a special order. Contact Omron. 33 Common To All Assemblies Common To All Assemblies Dimensions Unit: mm (inch) J LEGEND PLATE FRAMES A22Z-332j 40.8 (1.61) 50.8 (2.00) 20.5 (1.81) 29.8 (1.17) 27 (1.06) A22Z-333j 27 (1.06) 20.5 (1.81) 22.2 dia. 29.8 (1.17) J PLASTIC RECTANGULAR AND SHIELD A22N-PRj A22N-PXj 29.8 (1.17) 6.4 (0.25) 11.4 (0.45) 29.9 (1.18) 44.8 (1.76) 22.3 (0.88) Note: Curved dashed line denotes difference between Rectangular and Rectangular to Round name plates. J PLASTIC SQUARE A22N-PSj 44.8 (1.76) 6.4 (0.25) 11.4 (0.45) 29.9 (1.18) 44.8 (1.76) 22.3 (0.88) 34 22.2 dia. 28 dia. 28 dia. Common To All Assemblies Common To All Assemblies J METAL RECTANGULAR A22N-MRj 29.8 (1.17) 6.4 (0.25) 11.4 (0.45) 29.9 (1.18) 44.8 (1.76) 22.4 (0.88) 2 x 25.0 (0.98) 4 x 3.2 (0.13) J 60MM EMERGENCY STOP A22PE190 60.0 (2.36) White Letters Red 22.3 (0.88) J 90MM EMERGENCY STOP A22N-PE191 90.0 (3.54) White Letters Red 22.3 (0.88) 35 Common To All Assemblies Common To All Assemblies J LOCK FITTING J 25 MM-DIA. RING A22Z-3360 A22Z-R25 30 dia, (1.18) 22 dia. 24.8 dia. 27 dia. 22.2 dia. 20.5 (0.81) 2.8 (0.11) J COLOR LENS J HOLE PLUG (ROUND) A22L-30Tj A22Z-3530 23.4 dia. (0.92) 10.2 (0.40) 30 dia. 2.5 J SEALING CAPS For Flush Models A22Z-3600F For Extended Head Models A22Z-3600T 32 dia. 16.6 (0.65) 32 dia. 13 (0.51) 26 dia. (1.02) 23 (0.91) 22.2 dia. 33 dia. (1.30) For Full-guard Models A22Z-3600G 6 (0.24) 22.2 dia. 33 dia. (1.30) 31.5 dia. 24 (0.94) 22.2 dia. 32.5 dia. (1.28) 36 Common To All Assemblies Common To All Assemblies J THREE-THROW SPACER A22Z-3003 13.7 dia. (0.54) 10.8 (0.43) 12.9 dia. 11 (0.43) For Flush/Extended Models A22Z-3580 3.4 (0.13) 14.2 dia. (0.56) J METALLIC BEZEL RINGS For Full-guard Models A22Z-3582 28.7 dia. 24 dia. 28.7 dia. 24 dia. 11.5 (0.45) 18.5 (0.73) 29.7dia. (1.17) J SNAP-IN LEGEND PLATES 29.7dia. (1.17) For General-purpose Models A22L-3443j-j For Large Models A22Z-3453j 26.8 (1.06) 26.8 (1.06) 8.2 (0.32) 17.9 (0.70) J CHARACTER FILM For Round Models A22Z-3460-j 17 (0.67) For Square Models A22Z-3480 1.2 1.2 17 (0.67) 19.4 dia. (0.76) 21.5 x 21.5 (0.85 x 0.85) 37 Common To All Assemblies Common To All Assemblies Unit: mm (inch) J LAMP EXTRACTOR A22Z-3901 55 (2.17) 11 dia. (0.43) 8 dia. (0.31) 8.5 dia. J TIGHTENING WRENCH 25 dia. 30 dia. (1.18) 21.2 dia. 19.2 dia. A22Z-3905 90 (3.54) J LENS TIGHTENING TOOL A22Z-3908 23.4 (0.92) 5 dia. 20.5 (0.81) 30 (1.18) J LENS PULLER 20 (0.79) A3PJ-5080 15 (0.59) 10 (0.39) 50 (1.97) 25 (0.98) 38 Common To All Assemblies Common To All Assemblies J ENCLOSURES (POLYESTER) A22N-PENC-j Section Y-Y Top View with Cover Removed Section Z-Z 22.5mm Hole 3.37 (0.13) 2.25 (0.09) 1.97 (0.08) Hole Placement Overall Dimensions Inside Dimensions A B C D E F J K L M No. of Holes Hole Size A22N-PENC-1 6.74 3.93 3.88 6.01 3.26 3.63 5.99 3.18 4.88 2.94 1 22.5 A22N-PENC-2 6.74 3.93 3.88 6.01 3.26 3.63 5.99 3.18 4.88 2.94 2 22.5 A22N-PENC-3 8.99 3.93 3.88 8.26 3.26 3.63 8.24 3.18 7.13 2.94 3 22.5 Part No. 39 Common To All Assemblies Common To All Assemblies J ENCLOSURES (METALLIC) A22N-MENC-j D F 0.25 Dia 4 Places Typ. 0.56 0.25 Dia 4 Places Typ. 0.88 0.25 TYP 1.88 TYP (0.07) L 0.69 0.25 TYP 1.50 TYP (0.06) E Z G A 0.88 1.38 B W C Body Type MENC-6 through MENC-16 (hinged) Side View Body Type MENC-1 MENC-2, MENC-3 and MENC-4 (not hinged) 0.25 0.13 0.88 Dia. 0.38 0.88 0.48 0.88 Typical Pushbutton Detail Hinge Detail Retractable pin allows door to be mounted on left or right side Part No. No. of Holes A B A22N-MENC-1 1 3.25 A22N-MENC-2 2 A22N-MENC-3 C D 2.75 3.50 5.13 2.75 3 7.00 A22N-MENC-4 4 A22N-MENC-6 6 A22N-MENC-9 Overall Dimensions L W F G 1.88 3.75 1.71 2.50 4.25 3.06 3.56 2 3.50 1.88 5.63 1.71 4.38 6.13 3.06 5.44 3 2.75 3.50 1.88 7.50 1.71 6.25 8.00 3.06 7.31 3 8.88 2.75 3.50 1.88 9.38 1.71 8.13 9.88 3.06 9.19 4 8.50 5.00 4.25 4.13 9.00 3.96 7.75 9.50 5.31 8.81 5 9 8.50 6.50 4.25 5.63 9.00 5.46 7.75 9.50 6.81 8.81 6 A22N-MENC-12 12 10.38 6.50 4.25 5.63 10.88 5.46 9.36 11.38 6.81 10.69 6 A22N-MENC-16 16 10.38 8.00 4.25 7.13 10.88 6.96 9.63 11.38 8.31 10.69 7 40 Z Ship Wt. lbs. E Common To All Assemblies Common To All Assemblies Installation J MOUNTING THE PANEL J MOUNTING THE OPERATIONAL UNIT ON THE PANEL Panel Hole Dimensions 22 dia. (0.87) 3.2 (0.13) Insert the Operational Unit from the front surface of the panel, insert the Lock Fitting and the mounting nut from the terminal side, then tighten the nut. Before tightening, check that the rubber washer is present between the Operational Unit and the panel. 25 dia. (0.98) 24.1 (0.95) 22.3 (0.88) 22.3 (0.88) When using a Legend Plate Frame, put one rubber washer each between the Legend Plate Frame and the panel and between the Operational Unit and the Legend Plate Frame. (One rubber washer will be provided when one Legend Plate Frame is ordered.) 25 (0.98) Align the Lock Fitting with the groove in the casing, then insert the Lock Fitting so that its edge is located on the panel side. For 25 mm-dia. holes, always use 25 mm-dia. Rings. (Since the cutout dimensions are large, IP65 cannot be guaranteed unless 25-dia. Rings are used.) Tighten the mounting nut at a torque of 0.98 to 1.96 N * m {10 to 20 kgf * cm}. When using a Lock Ring, replace with the supplied Lock Fitting, insert the projecting part into the lock slot, and then tighten the mounting nut. If outer surface treatment such as paint is applied to the panel, the panel dimensions after outer surface treatment must meet the specified panel dimensions. J MATRIX INSTALLATION Hold here Rubber washer Mounting nut 1. The following panel hole dimensions apply when Switch Units and the Standard-size Legend Plate Frame Lock Fitting are mounted. A22Z Panel Projecting part A22N-PR, -MR, -PX 30 (1.18) 30 (1.18) Lock Fitting Panel 45 (1.77) 41 (1.61) When the panel cutout dimension is 25 mm dia., remove the supplied rubber washer and mount the 25 mm-dia. Ring as shown below. (Since the A22Z-R25 is not attached to the main body, order separately.) Operational Unit 2. The following panel hole dimensions apply when the Large-size Legend Plate Frame is mounted. A22N-S A22Z 30 (1.18) 22.3 dia. 25-dia. Ring (A22Z-R25) 45 (1.77) 22.3 dia. 25 dia. 41 (1.61) Lock Fitting Panel 45 (1.77) Lock Fitting 25 dia. 22.3 dia. Mounting nut Locking should be applied toward the Engraving Plate. Note: The above dimensions are the smallest-possible mounting dimensions. However, these dimensions do not apply to large Pushbutton Switches. For large Pushbutton Switches, determine the distance between holes, taking the Operational Unit and Legend Plate Frame into account. 41 Common To All Assemblies Common To All Assemblies Half-guard Indicators J MOUNTING THE SWITCH ON THE OPERATIONAL UNIT Put the tips of the Lens Tightening Tool (A22Z-3908) into the Color Lens slot and turn the Tool. Insert the Operational Unit into the Switch Unit, aligning the arrow mark inscribed on the Operational Unit with the lever on the Switch Unit, then move the lever in the direction indicated by the arrow in the following figure. Operational Unit J ASSEMBLING THE CAP Arrow mark Lighted Pushbutton Switch Lever Mount the Color Lens so that the protrusions inside the cap fit into the grooves in the Operational Unit. Grooves Protrusion inside cap Cap J REMOVING THE SWITCH Move the lever in the direction indicated by the arrow in the following figure, then pull the Operational Unit or the Switch Unit. Color Lens Since the lever has a hole with an inside diameter of 6.5 mm, the lever can be moved in the specified direction by inserting a screwdriver into the hole and then moving the screwdriver. Indicator Mount the Color Lens so that the protrusions inside the Operational Unit fit into the grooves in the cap. Screwdriver Protrusion Cap Grooves in the cap Color Lens J MOUNTING/REPLACING THE COLOR LENS Projection, Full-guard Grip and rotate the Color Lens with your fingers. 42 Common To All Assemblies Common To All Assemblies Square Pushbutton/Indicator Installing/Replacing on the Switch Unit Removing the Color Lens: Insert the protruding tip of the Lens Puller (A3PJ-5080) into the lens slot, hold the plate spring, and pull them to remove the Color Lens. Grip the indicator with your fingers, then rotate the indicator while pressing it against the Switch Unit. Plate spring Mounting the Color Lens: Mount the Color Lens on the flange and firmly push the Color Lens. When the Color Lens is inserted, check whether it operates properly. When replacing the Lamp, remove the Color Lens and diffusion plate with fingers or Lens Puller. Attach the Character Film properly so that it fits inside the protruding part of the diffusion plate. Then, match the diffusion plate to the square flange and insert the Lens. J CONTROL BOX (ENCLOSURE) Mounting the Switch The Standard-size Legend Plate Frame can be mounted. Mount the Frame as shown in the following diagram. Mount the Switch in the same way as for an ordinary panel. Flange Snap-in Legend Plate Diffusion plate Character Film Color Lens J EMERGENCY STOP SWITCH J INSTALLING/REMOVING THE SWITCH UNIT Insert the protrusion of the Tightening Wrench (A22Z-3905) into the Cap slot and then turn to remove the Cap. Installing the Switch Unit Hook the small protrusion on the Switch Unit into the groove on the other side of the lever, then push up the Switch Unit in the direction indicated by the arrow in the figure below. Lever Mounting Latch J INSTALLING/REPLACING THE LAMP Installing from the Panel Surface Insert the Lamp Extractor (A22Z-3901) into the lamp, then rotate the Extractor while pressing it. Protrusion Switch Unit 43 Common To All Assemblies Common To All Assemblies Removing the Switch Unit J ENGRAVING Insert a screwdriver between the Mounting Latch and the Switch Unit, then push down the screwdriver in the direction indicated by the arrow in the following figure. Engrave the characters on the surface on the Cap. Make sure that the characters are aligned parallel to the imaginary line connecting the two protruding portions to the left and right of the Cap. Use either of the following screwdrivers. Flat-head screwdriver The characters must not be engraved deeper than 0.5 mm. Apply an alcohol-based paint coating, such as melamine, alkyd, or acrylic resin paint coating, to the engraved characters. Phillips screwdriver Protruding portions on Cap J AFFIXING CHARACTER FILM Screwdriver Hold the Cap, remove the cardboard on the Film, and attach the Film to the Cap. Make sure that the protruding portions of the Cap engage the cutout portions of the Film and that the characters are aligned parallel to the imaginary line connecting the two protruding portions to the left and right of the Cap. J WIRING Wiring Round Crimp Terminals Remove the cardboard. Loosen the terminal screw from the Switch Unit until it completely comes off the groove, insert a screwdriver as shown in the following figure, then push up the washer in the direction indicated by the arrow to temporarily secure it. Now, a round crimp terminal can be connected. After inserting the terminal, tighten the screws to complete wiring. Protruding portions on Cap J MOUNTING AND DISMOUNTING SNAP-IN LEGEND Washer Press and secure the Snap-in Legend Plate onto the Legend Plate Frame. Screw The direction of the characters will vary with the mounting direction of the control panel if the Switch is a knob or key selector model. Screwdriver Legend Plate Frame Snap-in Legend Plate Concave surface 44 Common To All Assemblies Common To All Assemblies To easily remove the Snap-in Legend Plate from the Legend Plate Frame mounted to the panel, insert a Tool with a thin tip into the space between the Snap-in Legend Plate and the Legend Plate Frame. J ENGRAVING METHOD Material: Acrylic Engrave the characters directly on the matted side of the Snap-in Legend Plate. The characters must be engraved no deeper than 0.5 mm. Apply alcohol-based paint coating to the engraved characters. If the Snap-in Legend Plate is transparent, engrave the mirror-written characters on the back of the Snap-in Legend Plate and apply paint coating to the characters. Then apply paint coating of a different color to the remaining part of the Snap-in Legend Plate. J MOUNTING THREE-THROW SPACER Press and secure the two protruding portions of the Three-throw Spacer to the two indented portions of the inner side of the control panel. The Snap-in Legend Plate is easily removed by pressing the Snap-in Legend Plate from the back of the Legend Plate Frame. The Legend Plate Frame is made of acrylic resin, which is easily damaged by shock. Be sure to handle the Legend Plate Frame with care. Precautions ! WARNING Wiring After wiring the Switch, maintain an appropriate clearance and creepage distance. Do not apply a voltage between the incandescent lamp and the terminal that is greater than the rated voltage. If the incandescent lamp is broken, the Operational Units may pop out. Always turn OFF the power and wait for 10 minutes before replacing the incandescent lamp. If the lamp is replaced immediately after the power is turned OFF, the remaining heat may cause burns. When DC-specific LEDs are used, wire the Switch so that the X1 terminal is positive. Terminal screws must be Phillips or slotted M3.5 screws with a square washer. The tightening torque is 1.08 to 1.27 N * m {11 to 13 kgf * cm}. J CORRECT USE Single wires, stranded wires, and crimp terminals can be connected to the Switch. Mounting Operating Environment Always make sure that the power is turned OFF before mounting, removing, or wiring the Switch, or performing maintenance. The IP65 model is designed with a protective structure so that it will not sustain damage if it is subjected to water from any direction to the front of the panel. Do not tighten the mounting ring more than necessary using tools such as pointed-nose pliers. Doing so will damage the mounting ring. The tightening torque is 0.98 to 1.96 N * m {10 to 20 kgf * cm}. The panel thickness is 1 to 5 mm. 45 Common To All Assemblies Common To All Assemblies Using the Microload Others Insert a contact protection circuit, if necessary, to prevent the reduction of life expectancy due to extreme wear on the contacts caused by loads where inrush current occurs when the contact is opened and closed. The oil-resistant IP65 uses NBR rubber and is resistant to general cutting oil and cooling oil. Some particular oils cannot be used with the oil-resistant IP65, however, so contact your OMRON representative for details. The minimum applicable load is the N-level reference value. This value indicates the malfunction reference level for the reliability level of 60% ( 60) (conforming to JIS C5003). If the panel is to be finished with coating, etc., make sure that the panel meets the specified dimensions after the coating. Do not subject the Switch to extreme shock or vibration. Doing so will cause malfunctions and damage to the Switch. The equation, 60 = 0.5 x 10--4/time indicates that the estimated malfunction rate is less than 1/2,000,000 with a reliability level of 60%. Do not let sharp objects come into contact with the Switches that are made of resin. Doing so will damage the Switches, causing scratches on the outside of the Operational Units, and malfunction. When handling the Switches, do not throw or drop them. Voltage (V) Area of use General-purpose load area Do not allow the Switch to drop and hit the ground. Microload area Invalid area Current (mA) LEDs The LED current-limiting resistor is built-in, so internal resistance is not required. If commercially available LEDs are used, select the ones that meet the following conditions: Do not place or drop heavy objects on the Switch. Base: BA9S/13j Overall length: 26 mm max. Power consumption: 2.6 W max. Do not operate the Switch with hard or sharp objects. Hammer 46 Screwdriver Custom Engraved Nameplate Order Form - A22N Series Copy this form and utilize it to specify Custom Engraved Nameplates. Once completed: Mail the completed form to: Omron LLC, One Commerce Drive, Schaumburg, Il. 60173-5302 Or fax to either Omron LLC at: 847.843.8261 or your local field sales office. Bill to: Address:__________________________________________ City/State/Zip:______________________________________ Attention:__________________________________________ Ship to: Address:___________________________________________ City/State/Zip:_______________________________________ Attention:___________________________________________ Step 1) Step 2) Step 3) Date:___________________________ Your Name:______________________ P.O.#___________________________ Phone:__________________________ Fax:____________________________ Phone:__________________________ Select blank legend plate from the four depicted below (either A, B, C, or D). Write your choice in the small box under Legend Type and fill in the box marked Quantity. Print text as it should appear on the finished nameplate. Plastic Shield Shape A A22N--PX200E Plastic Rectangular B Plastic Square Metal Rectangular A22N--PS200E A22N--MR200E C A22N--PR200E D 11 Characters per Line Maximum, 2 Lines Maximum, Legend Quantity Type Legend Quantity Type ___________ ___________ Legend Quantity Type ___________ Legend Quantity Type ___________ ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ ___________ ___________ 47 Legend Quantity Type Legend Quantity Type ___________ ___________ Legend Quantity Type ___________ Legend Quantity Type ___________ ___________ Legend Quantity Type Legend Quantity Type ___________ Legend Quantity Type ___________ Legend Quantity Type ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ ___________ Legend Quantity Type ___________ ___________ ___________ ___________ YourSignature_______________________________________________________Date______________________ 48 Common To All Assemblies Common To All Assemblies Complete "Terms and Conditions of Sale" for product purchase and use are on Omron's website at www.omron247.com -- under the "About Us" tab, in the Legal Matters section. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. R OMRON ELECTRONICS LLC 1 Commerce Drive Schaumburg, IL 60173 Tel: 847.843.7900 For U.S. technical support or other inquiries: 800.556.6766 MEXICO SALES OFFICES OMRON ON-LINE Mexico, D.F. Ciudad Juarez Monterrey, N.L. Queretaro Global -www.omron247.com 555.660.3144 656.623.7083 818.377.4281 442.135.4510 BRAZIL SALES OFFICE OMRON CANADA, INC. Sao Paulo 885 Milner Avenue Toronto, Ontario M1B 5V8 Tel: 416.286.6465 ARGENTINA SALES OFFICE Cono Sur 55.11.2101.6310 54.114.787.1129 CHILE SALES OFFICE Santiago 562.206.4592 USA -www.omron247.com Canada -www.omron.ca Brazil -www.omron.com.br Latin America -mela@omron.com OTHER LATIN AMERICAN SALES mela@omron.com Cat. No. A108-E3-02 03/07 Specifications subject to change without notice. Printed in U.S.A.