PRESSURE SENSORS
DP-100 Series
Self Contained ● 0.1kPa Resolution ● 2.5ms Response Time
DPC-100/DPH-100 Series
Separate Head and Amplifi er ● Miniature Head Design ● 0.5ms Response Time
Type Pressure Range Output Confi guration Output Model
R1/8 Male NPT1/8 Male G1/8 Male M5 Female
Low Pressure
±100 kPa
2 Discrete Outputs NPN DP-101 DP-101-N DP-101-M
PNP DP-101-N-P DP-101-E-P DP-101-M-P
1 Discrete Output + 1 Analog Output NPN DP-101A DP-101A-N DP-101A-M
PNP DP-101A-N-P DP-101A-E-P DP-101-M
M8
Type
2 Discrete Outputs PNP DP-111-E-P-J
1 Discrete Output + 1 Analog Output DP-111A-E-P-J
High Pressure
-0.1 to 1.0MPa
2 Discrete Outputs NPN DP-102 DP-102-N DP-102-M
PNP DP-102-N-P DP-102-E-P DP-102-M
1 Discrete Output + 1 Analog Output NPN DP-102A DP-102A-N DP-102A-M
PNP DP-102A-N-P DP-102A-E-P DP-102A-M-P
M8
Type
2 Discrete Outputs PNP DP-112-E-P-J
1 Discrete Output + 1 Analog Output DP-112A-E-P-J
DPC-L100/DPH-L100 Series
Separate Head and Amplifi er ● For Liquids and High Pressures ● 5ms Response Time
Air
DP-100 Series
• Self Contained Design
• M8 Quick Connection Available
• Pressure Range: -0.1 to 1.0 MPa
DPC-100 / DPH-100 Series
• Separate Head and Amplifi er
• High Flex Cable Models Available
• Pressure Heads Can Be Used Independently
• Pressure Range: -0.1 to 1.0 MPa
Water / Oil
DPC-L100 / DPH-L100 Series
• Separate Head and Amplifi er
• For Air, Water, Oil, and Other Liquids
• Pressure Heads Can Be Used Independently
• Pressure Range: -0.1 to 50.0 MPa
RUN Mode
Settings such as
threshold value
adjustment and key lock
operation can be carried
out while the sensor is
operating.
Basic settings such as
output mode setting and
NO/NC switching can be
carried out.
PRO Mode
High-level function
settings such as
hysteresis adjustment and
the copy function can be
carried out.
RUN Mode
PRO Mode
MENU SETTING Mode
Simple
Setting
Special &
Detailed Setting
Three Level Confi guration
The setting levels are clearly separated into
“RUN mode” for operation settings that are
carried out daily, “MENU SETTING mode” for
basic settings, and “PRO mode” for special
and detailed setting. These make setting
operations easy to understand and easy to
carry out.
Three Color Digital Display
The main display color switches between green and red in accordance with the
ON/OFF status of output during RUN mode. In addition, the display always appears
orange while setting is in progress, so that the status of the controller can be viewed at
a glance.
Orange while
setting is in progress.
Display in
red or green
depending
on output
ON / OFF.
Menu Setting ModeRUN Mode PRO Mode
OFF: Green (or Red) ON: Red (or Green) SET: Orange
Panasonic pressure sensors are easy to use and deliver the
highest level of performance. Our product line can detect
air, water, oil, and other liquids with pressures up to 50MPa.
Whether you need high resolution or high speed detection,
our pressure sensors have you covered.
Menu Setting Mode
Controllers Sensor Heads
Model Number Type Pressure Range Port Size Model
NPN Outputs PNP Outputs STD Cable High Flex Cable
DPC-101 DPC-101-P
Compound Pressure ±100 kPa
R1/8 Male + M5 Female DPH-101 DPH-101-R
M3 Male DPH-101-M3 DPH-101-M3-R
M5 Male DPH-101-M5 DPH-101-M5-R
Positive Pressure 0 to 1.0MPa R1/8 Male + M5 Female DPH-102
M5 Male DPH-102-M5
Vacuum Pressure 0 to -101.0 kPa
R1/8 Male + M5 Female DPH-103 DPH-103-R
M3 Male DPH-103-M3 DPH-103-M3-R
M5 Male DPH-103-M5 DPH-103-M5-R
Controllers Sensor Heads
Model Number Type Pressure Range Port Size Model
NPN Outputs PNP Outputs Compound Pressure -0.1 to 1.0 MPa
R1/4 Male
DPH-L113V
DPC-L101 DPC-L101-P Positive Pressure
0 to 1.0MPa DPH-L113
0 to 3.5 MPs DPH-L133
0 to 10 MPa DPH-L114
0 to 50 MPa DPH-L154