Through Hole Lamp Product Data Sheet LTL-4231NHBP Spec No.: DS-20-97-0014 Effective Date: 11/23/2012 Revision: E LITE-ON DCC RELEASE BNS-OD-FC001/A4 LITE-ON Technology Corp. / Optoelectronics No.90,Chien 1 Road, Chung Ho, New Taipei City 23585, Taiwan, R.O.C. Tel: 886-2-2222-6181 Fax: 886-2-2221-1948 / 886-2-2221-0660 http://www.liteon.com/opto LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Features * Lead (Pb) free product - RoHS compliant. * Designed for ease in circuit board assembly. * Black case enhance contrast ratio. * Solid state light source. * Reliable and rugged. Package Dimensions Part No. Lens Source Color LTL-4231NHBP Green Diffused Green NOTES: 1. All dimensions are in millimeters (inches). 2. Tolerance is 0.25mm(.010") unless otherwise noted. 3. The holder color is black, the material in plastic. 4. The LED lamp is LTL-4231N. 5. Specifications are subject to change without notice. Part No. : LTL-4231NHBP BNS-OD-C131/A4 Page : 1 of 7 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Absolute Maximum Ratings at Ta=25 Parameter Maximum Rating Unit 100 mW 120 mA DC Forward Current 30 mA Derating Linear From 50 0.4 mA/ Operating Temperature Range -55 to + 100 Storage Temperature Range -55 to + 100 Power Dissipation Peak Forward Current (1/10 Duty Cycle, 0.1ms Pulse Width) Lead Soldering Temperature [1.6mm(.063") From Body] Part No. : LTL-4231NHBP BNS-OD-C131/A4 260 for 5 Seconds Max. Page : 2 of 7 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Electrical / Optical Characteristics at TA=25 Parameter Luminous Intensity Symbol Min. Typ. Max. Unit IV 5.6 12.6 50 mcd 21/2 60 deg Peak Emission Wavelength P 565 nm Dominant Wavelength d Viewing Angle 564 569 30 Forward Voltage VF 2.1 Reverse Current IR Spectral Line Half-Width 574 nm Test Condition IF = 10mA Note 1,4 Note 2 (Fig.6) Measurement @Peak (Fig.1) Note 3 nm 2.6 V 100 A IF = 20mA VR = 5V Note: 1. Luminous intensity is measured with a light sensor and filter combination that approximates the CIE (Commission International De L'Eclairage) eye-response curve. 2. 1/2 is the off-axis angle at which the luminous intensity is half the axial luminous intensity. 3. The dominant wavelength, d is derived from the CIE chromaticity diagram and represents the single wavelength which defines the color of the device. 4. The Iv guarantee should be added 15% . 5. Reverse voltage (VR) condition is applied for IR test only. The device is not designed for reverse operation. Part No. : LTL-4231NHBP BNS-OD-C131/A4 Page : 3 of 7 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Typical Electrical / Optical Characteristics Curves (25 Ambient Temperature Unless Otherwise Noted) Part No. : LTL-4231NHBP BNS-OD-C131/A4 Page : 4 of 7 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only Packing Spec. Part No. : LTL-4231NHBP BNS-OD-C131/A4 Page : 5 of 7 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only CAUTIONS 1. Application The LEDs described here are intended to be used for ordinary electronic equipment (such as office equipment, communication equipment and household applications). Consult Liteon's Sales in advance for information on applications in which exceptional reliability is required, particularly when the failure or malfunction of the LEDs may directly jeopardize life or health (such as in aviation, transportation, traffic control equipment, medical and life support systems and safety devices). 2. Storage The storage ambient for the LEDs should not exceed 30C temperature or 70% relative humidity. It is recommended that LEDs out of their original packaging are used within three months. For extended storage out of their original packaging, it is recommended that the LEDs be stored in a sealed container with appropriate desiccant or in a dessicator with nitrogen ambient. 3. Cleaning Use alcohol-based cleaning solvents such as isopropyl alcohol to clean the LEDs if necessary. 4. Lead Forming & Assembly During lead forming, the leads should be bent at a point at least 3mm from the base of LED lens. Do not use the base of the leadframe as a fulcrum during forming. Lead forming must be done before soldering at normal temperature. During assembly on PCB, use minimum clinch force possible to avoid excessive mechanical stress 5. Soldering When soldering, leave a minimum of 2mm clearance from the base of the lens to the soldering point. Dipping the lens into the solder must be avoided. Do not apply any external stress to the lead frame during soldering while the LED is at high temperature. Recommended soldering condition (for Lamp): Soldering iron Temperature Soldering time Wave soldering 300C Max. 3 sec. Max. (one time only) Pre-heat Pre-heat time Solder wave Soldering time 100C Max. 60 sec. Max. 260C Max. 10 sec. Max. Note: Excessive soldering temperature and/or time might result in deformation of the LED lens or catastrophic failure of the LED. IR re-flow is not suitable process for through hole type LED lamp production. 6. Drive Method An LED is a current operated device, In order to ensure intensity uniformity on multiple LEDs connected in parallel in an application; it is recommended that a current limiting resistor be incorporated in the drive circuit. In series with each LED as shown in Circuit A below. (A) Recommended circuit. Circuit model A LED Circuit model B LED (B) The brightness of each LED might appear different due to the differences in the I-V characteristics of those LEDs Part No. : LTL-4231NHBP BNS-OD-C131/A4 Page : 6 of 7 LITE-ON TECHNOLOGY CORPORATION Property of Lite-On Only 7. ESD (Electrostatic Discharge) Static Electricity or power surge will damage the LED. Suggestions to prevent ESD damage. Use a conductive wrist band or anti-electrostatic glove when handling these LEDs. All devices , equipment , and machinery must be properly grounded. Work tables , storage racks , etc. should be properly grounded . Use ion blower to neutralize the static charge which might have built up on surface of the LED's plastic lens as a result of friction between LEDs during storage and handling. ESD-damaged LEDs will exhibit abnormal characteristics such as high reverse leakage current, low forward voltage, or "no lightup" at low currents. To verify for ESD damage, check for "lightup" and Vf of the suspect LEDs at low currents. Suggested checking list : Training and Certification 1. Everyone working in a static-safe area is ESD-certified? 2. Training records kept and re-certification dates monitored? Static-Safe Workstation & Work Areas 1. Static-safe workstation or work-areas have ESD signs? 2. All surfaces and objects at all static-safe workstation and within 1 ft measure less than 100V? 3. All ionize activated, positioned towards the units? 4. Each work surface mats grounding is good? Personnel Grounding 1. Every person (including visitors) handling ESD sensitive (ESDS) items wears wrist strap, heel strap or conductive shoes with conductive flooring? 2. If conductive footwear used, conductive flooring also present where operator stand or walk? 3. Garments, hairs or anything closer than 1 ft to ESD items measure less than 100V*? 4. Every wrist strap or heel strap/conductive shoes checked daily and result recorded for all DLs? 5. All wrist strap or heel strap checkers calibration up to date? Note: *50V for Blue LED. Device Handling 1. Every ESDS items identified by EIA-471 labels on item or packaging? 2. All ESDS items completely inside properly closed static-shielding containers when not at static-safe workstation? 3. No static charge generators (e.g. plastics) inside shielding containers with ESDS items? 4. All flexible conductive and dissipative package materials inspected before reuse or recycles? Others 1. Audit result reported to entity ESD control coordinator? 2. Corrective action from previous audits completed? 3. Are audit records complete and on file? 8. Others The appearance and specifications of the product may be modified for improvement, without prior notice. Part No. : LTL-4231NHBP BNS-OD-C131/A4 Page : 7 of 7 Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: Lite-On: LTL-4231NHBP