Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters TE Connectivity (TE) offers over 300 solutions for RFI problems associated with susceptibility, as well as compliance with international emissions standards. TE Connectivity Corcom Products Engineering Offices USA 620 S. Butterfield Road Mundelein, IL 60060 Phone: 847-680-7400 Fax: 847-680-8169 6700 Fallbrook Ave. Suite 287 West Hills, CA 91307 Phone: 818-226-4306 Fax: 818-704-1757 IEC Inlet Filters and Power Entry Modules A complete line of power entry modules solves a variety of power entry needs by combining functions to reduce cost, space and labor. Germany Finsinger Feld 1 D-85521 Ottobrunn, Phone: 49-89-6089-0 Fax: 49-89-6089-767 People's Republic of China DC Filters TE has developed a wide range of power line filters and power entry modules that combine several power management functions specifically designed for DC applications. Feedthrough Filters and Capacitors 668 Guiping Road Shanghai, 200233 Phone: 86-21-2407-1588 Fax: 86-21-2407-1599 For Sales assistance in the USA please refer to page 286 to find a Corcom product sales representative in your area. For Sales assistance in all other regions, please refer to page 289 to find the Product Information Center in your area. Designed to offer reliability and performance in high frequency applications and meet EN132200 and 132400 safety requirements. Available for AC or DC applications. Signal Line Products The SignalSentry filtered modular jack connector series combines different levels of filtering with RJ45 and RJ11 modular jacks to address signal line noise problems and crosstalk. Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Main Table of Contents Navigating the Catalog . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 1. RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9 RFI Power Line Filter Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 AQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 DK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 EBP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EDP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EOP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EMC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 EP & VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 FC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 FL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 HQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 HT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 HZ Series NEW 4, 6, 10 and 20A versions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 IK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 MV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Q Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 R Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 RK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 SB Series NEW High Performance B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 SK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 V Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 W Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 WG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Y Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 2. Three Phase Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 Three Phase Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 A Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98 ADT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 AYA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104 AYC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 AYO Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 BCF Series NEW Compact Three Phase Filters . . . . . . . . . . . . . . . . . . . . . . . . . .113 CFN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 FCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 3. Power Inlet Filters & Power Entry Modules . . . . . . . . . . . . . . . . . . . . . . .125 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126 Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128 Power Entry Module Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CU Series NEW Compact 1U Height Power Entry Module . . . . . . . . . . . . . . . .134 EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138 EC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 ED Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144 EEA & EEB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EAH & EBH Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 1 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Table of Contents (continued) EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJM & EJMS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160 EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 GG & HG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175 LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192 SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 4. DC Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .209 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210 Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211 DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212 DB Series NEW - Compact RFI High Current DC Inlet . . . . . . . . . . . . . . . . . . . .214 DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217 P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 5. Feedthrough Filters and Capacitors . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 Feedthrough Application Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .225 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 FFA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228 FFD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231 AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234 DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237 6. Signal Line Products . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .241 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 SignalSentry Filtered Modular Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243 SignalSentry Part Number Matrix / Ordering Information . . . . . . . . . . . . . . . . .244 SignalSentry Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245 L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247 L - Ganged Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 LC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249 LCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253 Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255 L, LC, LCT and X Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . .255 N and Z Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257 7. Technical Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .261 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262 Understanding RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263 Understanding Hipot Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266 Understanding Leakage Current (Touch Current) . . . . . . . . . . . . . . . . . . . . . . . . .267 Understanding Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268 Appendix A - Conducted RFI Emissions Testing . . . . . . . . . . . . . . . . . . . . . . . . . .269 Appendix B - Conducted RFI Susceptibility Testing . . . . . . . . . . . . . . . . . . . . . . .270 Appendix C - Health Care Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270 Appendix D - Safety Agency File Numbers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .271 Part Number Index and Cross Reference . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .273 North American Sales Representatives . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .286 Authorized Corcom Product Distributors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .288 Worldwide Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Inside Back Cover 2 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Navigating the Catalog Step 1: Determine the product family. The Corcom product guide contains seven sections with six distinct product families. Use the index numbers along the side of the catalog to quickly jump to that section. RFI Power Line Filters 1 Solutions associated with EMI/RFI susceptibility as well as compliance to international emissions standards for single phase power applications. Includes chassis and board mountable designs as well as single and two-stage filters. Three Phase Filters 2 Corcom Product Families Solutions associated with EMI/RFI susceptibility as well as compliance to international emissions standards for three phase and high current applications. IEC Inlet and Power Entry Modules 3 IEC inlet power filters and modular products that address a variety of power entry needs by combining several functions such as on/off switching, voltage selection switching, fuseholder, filtering in combination with the IEC inlet connector. DC Power Line Filters 4 EMI/RFI solutions for emissions and susceptibility specifically related to DC systems often found in central office and telecommunication applications. Feedthrough Filters and Capacitors 5 Products designed for through-bulkhead mounting for high frequency filtering. Designed to meet EN133200 and EN132400 safety requirements. Available in a variety of standard as well as custom configurations. Signal Line Products 6 Products that combine different levels of filtering with various sized RJ modular jacks. Signal line products are used to protect data transmissions as they pass through the RJ jacks or as they are transmitted on the PCB. Technical Notes 7 The appendices in the back of the catalog offer information such as safety agency classifications, general information regarding RFI, and testing procedures. (continued on next page ) Looking for Corcom EMI Facility Products? Power, data and signal line filters for shielded installations Available in Catalog 1654986 - see page 8 for more information 3 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Step 2: Use selector charts For Medical Application (continued) No Selector charts at the beginning of each section help you to narrow the selection. Attenuate Conducted RFI / EMI Yes For Hardened Equipment Applications Coming Out of Equipment Yes Try The No Coming Into Equipment Try The Follow the chart to locate one or several MV Series product series that could fit your specific 3-20A Page 54 application and requirements. HZ No Yes Yes Try The No Selector charts generally show filters in order of performance from good (at the top) to best performance (at the bottom). Series 1- 6A Page 92 RK Series 3-20A Page 65 Try The Try The B EBP, EDP,EOP SK Series 1-30A Page 15 Series 1-10A Page 21 Series 3-40A Page 75 EMC Try The Series 3-30A Page 24 EMC K SB Z S Series 3-30A Page 24 Series 1-60A Page 49 Series 6- 30A Page 71 Series 1-3A Page 92 Series 3-60A Page 68 FC DK K U V/W DK N EP / VP Series 1-20A Page 18 Series 6-10A Page 56 Series 3-20A Page 27 NEW B Series 1- 30A Page 15 NEW SB Series 6- 30A Page 71 Step 3: Open to the page referenced by the selector chart from X, Y or Z Class B 3-6A Page 37 All Series Are Listed in Ascending Performance Class A NEW HT Optimal filter selection requires testing in Series 6-15A Page 40 your specific system, as all systems have HQ unique characteristics. Series Series 3-6A Page 12 For EN550xxx (CISPR) For High Noise Industrial Application Series 3A Page 43 AQ For Switch Mode Power Supply Try The N ew 6 0 A Navigating the Catalog Series majority Series of questions Series Series Series Each product series contains three technical sections. The relating 1-20A 1-60A 6A 3-20A 6-50A Page 18 Page 49 Page 84 Page 86 Page 30 to product applications can be answered directly from these sections. Good Better WG Series 16A Page 89 New Terminations S Series 3-60A Page 68 New 60A to R V/W EDP - EOP G Q Technical Characteristics: This first section contains pictures, appropriate safety agency Series Series Series Series Series 1-20A 3-20A 1-10A 6-10A 3-20A classifications, a description of the series' capabilities, applications, electrical Page 61 Page 86 Page 21 Page 35 Page 58 specifications, schematics, ordering information and available part FC T R EMC numbers. T to Best Series 3-20A Series 1-20A Series 3-30A Series 6-50A Series 3-20A 30 Page 80 61 Page 24of the Page Page 80 as and Page dimensions parts as well Drawings: The second section contains drawings the recommended cutouts. Dimensions are shown in inches with metric equivalents. Performance Data: The third section contains performance data in the form of typical insertion loss graphs and minimum insertion loss tables. If you already know the catalog number or series, the table of contents lists each series in the catalog within each section. The back of the catalog also has an index in alphanumeric order. The index will reference the technical section for that catalog number or series. The index also provides the unique TE ordering number for each part. Step 4: Contact your local Corcom product sales representative Corcom product sales representatives for North America as well as distributors and global contacts are listed in the back of the catalog. Contact the sales representative or office closest to you for technical assistance, stock and pricing. 4 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide e bl E C o ol cient ffi Relia Corcom EMI/RFI Filters and Energy Efficiency The efficiency of an electrical device is the ratio of the power it delivers to the power that it consumes. The difference is wasted as heat, and to prevent overheating of a device and the system in which it resides, this heat must be transferred out of the system and dissipated. The efficiency of every component, including the power entry module and selected filter, factors into the system's overall efficiency. When the amount of heat is too great to dissipate through the system's enclosure, forced air cooling becomes necessary. This is often accomplished with a fan, and the power used by that fan, (including its own thermal losses) further decreases the system efficiency by another 2% to 5%. Providing room for the fan and air passageways in the equipment increases its size and cost. Careful attention to the efficiency of every component in the system results in a simpler, smaller, lighter, cooler, more competitive product. Corcom EMI filters can help meet energy efficiency goals, including Energy Star rating and the new 80 Plus certification, which now recognizes systems that exceed 90% efficiency. By using the most energy efficient design and materials, Corcom filters can be the beginning of an energy efficient system strategy. Energy efficient power components don't just lower energy bills and demand for power from the grid, they also increase product reliability. Small efficiency increases can decrease component temperatures throughout the system, and semiconductor life doubles for every 10C decrease in temperature. Corcom filters are more efficient and run cooler, and this can help reduce system warranty costs, service calls and total support costs. Corcom filters * Have heat dissipation ratings as little as one third that of comparable filters. * Create less heat and run cooler * Improve system reliability * Are more efficient than PC board equivalents * Can help meet system power efficiency standards * Enable systems to be smaller and lighter * Save customers money by reducing energy costs 500 Heat Dissipation in mW/A 450 400 350 300 250 200 150 100 50 Other Power Entry Modules 0 Corcom CU Series 1A 3A 5 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Corcom Products Engineering Services and Custom Solutions Corcom Products Engineering Services and Custom Solutions TE Connectivity Corcom products were established as the world leader in EMI/RFI filtering technology with the introduction of the first line of catalog filter products over 50 years ago. Corcom Custom Filters Key Features: Today, TE continues to pursue the latest in EMI/RFI filter design by testing and evaluating application specific solutions for a wide range of industries. * Custom wire harness design In addition to our complete catalog of standard EMI/RFI filtering solutions, TE offers a full range of engineering services and custom products designed for unique applications. Corcom custom EMI/RFI product solutions can: * Custom filter options * Fully customizeable options including packaging * Agency approvals available as needed by customer * Time and cost savings to customer * Optimize both cost and performance to target a unique application * Simplify installation * Fit unique mechanical size, installation and/or connection requirements Termination and Wiring Customization Options: * Ensure conformance with EMI/RFI requirements of an entire system * Wire length * Apply EMI/RFI filtering in a specific frequency or range * Wire color * Wire gauge With design and testing facilities worldwide, TE is well suited to design an EMI/RFI solution that meets a wide range of unique application needs. * Molded connectors * Ring terminals * Custom terminations To discuss application specific filtering, contact the TE Corcom product sales representative or office closest to you. A complete list of sales representative and worldwide contacts is listed in the back of this catalog. 6 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Corcom Engineering Services and Custom Solutions EMI/RFI Testing Services Corcom Products Test Lab Key Features: An increase in electronic content and stringent regulatory compliance requirements have increased the need for time spent in qualifying test houses. At these "test labs," products undergo a * We can test product number of qualifying tests which include conducted emissions, to the FCC / EN / EFT EFT, and harmonic content. Failure to comply with associated specifications standards can lead to delayed time-to-market and product * Let us know your testing needs and time redesign resulting in lost revenue and market share and an frame to ensure increase in time spent at the test lab. flexibility of testing and timely results Available Testing Standards: * Conducted EMI in accordance with FCC part 15 and 18 * EN55011, EN55022 and EN55014 * EFT (Electrically Fast Transient) in accordance with EN61000-4-4 TE Connectivity can help by heading off some of the potential pitfalls during testing and qualifying phases of new products. We offer complimentary testing to existing regulatory standards. We aim for a high standard of accuracy, and can help identify potential problems. We are not a certifying body and our test lab is not a qualified test lab; however, we test to the same standards and take product through the same rigor as any certifying lab. In addition, our engineers will recommend a solution and help with a design should a product fail to comply with conducted emissions, EFT and/or harmonic content standards. The advantage is clear: TE will provide you with a high degree of confidence that a product which passed our * Tests conducted up to 30A with insertion loss in-house testing will pass agency testing at a certifying test house measured up to 10GHz in reduced time and with reduced cost. * MIL-STD-461 CE101 & CE102 TE has three Corcom filter testing facilities: * Mundelein, IL, USA (main office and design center) * West Hills, CA, USA (regional office) * Ottobrunn, Germany (regional office and design center) 7 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Corcom EMI / RFI Product Solutions for Facility and Heavy Power Corcom EMI Facility Products Power, data and signal line filters for shielded installations TE Connectivity has dedicated more than 50 years to developing RFI filter technology for electronic devices. We're proud that our focus on the design and production of the highest quality products has made TE a world leader in RFI technology. Our leadership in the filter and power entry module markets was enhanced in 1988 with the aquisition of the Heavy Power Line Division of Cornell Dubilier. The high quality designs and manufacturing of these heavy power line filter products is maintained and enhanced by TE. We have continued that dedication to excellence begun by Cornell Dubilier and inherent to TE's way of doing business. Only the highest quality designs, capacitors, inductors, and workmanship are used to produce these filters. We recognize the need for great care demanded by hi-rel military filters and automatically apply like quality to the heavy power line products. We treat all product as if it is high-reliability. The Mundelein, IL office provides application engineering service for these heavy power line and military products. Our engineers can help to design a special filter in the rare case a standard product from this catalog cannot adequately solve the problem. Additional product performance data and test results are available from the engineers at this facility. TE's worldwide sales offices can help you locate information on these products or any of the hundreds of high quality power line filters, power entry modules and SignalSentry products made by TE. For more information on the complete line of EMI Facility products, request catalog number 1654986 or visit www.corcom.com 8 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 1. RFI Power Line Filters -- Table of Contents RFI Power Line Filter Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11 AQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12 B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15 DK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 EBP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EDP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EOP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21 EMC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 EP & VP Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27 FC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30 FL Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .33 G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .35 HQ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .37 HT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40 HZ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .43 IK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .46 K Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49 MV Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .56 Q Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .58 R Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .61 RK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .65 S Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .68 SB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71 SK Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .75 T Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .80 U Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .84 V Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 W Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .86 WG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .89 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Y Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .92 1 RFI Power Line Filters 9 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 10 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filter Selector Chart For Medical Application No Attenuate Conducted RFI / EMI Yes For Hardened Equipment Applications Coming Out of Equipment 1 Yes Try The No MV Series 3-20A Page 54 No For Switch Mode Power Supply HZ HT For EN550xxx (CISPR) For High Noise Industrial Application Series 3A Page 43 Yes Yes Class A Try The No Series 6-15A Page 40 X, Y or Z Class B Series 1- 6A Page 92 HQ Good to to Best B EBP, EDP,EOP SK Series 1-30A Page 15 Series 1-10A Page 21 Series 3-40A Page 75 SB B EMC Series 6- 30A Page 71 Series 1- 30A Page 15 Series 3-30A Page 24 EMC K Series 3-30A Page 24 Series 1-60A Page 49 Try The SB Z S Series 6- 30A Page 71 Series 1-3A Page 92 Series 3-60A Page 68 FC DK K U V/W Series 6-50A Page 30 Series 1-20A Page 18 Series 1-60A Page 49 Series 6A Page 84 Series 3-20A Page 86 DK N EP / VP Series 1-20A Page 18 Series 6-10A Page 56 Series 3-20A Page 27 S Better Try The Series 3-60A Page 68 WG Series 16A Page 89 New Terminations from Try The New 60A All Series Are Listed in Ascending Performance RK Series 3-20A Page 65 Try The NE W NEW NEW Series 3-6A Page 37 V/W EDP - EOP R Q G Series 3-20A Page 86 Series 1-10A Page 21 Series 1-20A Page 61 Series 3-20A Page 58 Series 6-10A Page 35 T R EMC FC T Series 3-20A Page 80 Series 1-20A Page 61 Series 3-30A Page 24 Series 6-50A Page 30 Series 3-20A Page 80 N ew 6 0 A Try The AQ Series 3-6A Page 12 RFI Power Line Filters Coming Into Equipment 11 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Frequency Power Line Filter or Power Entry Module AQ Series UL Recognized CSA Certified 3VAQ8F 6VAQ8F AQ Series Specifications * Low cost solution to power line noise at high frequencies * High common and differential mode performance from 10kHz to 1GHz * Available with an IEC inlet, fuseholder and switch * Suitable for applications where computers are used to process secret or confidential information Ordering Information Maximum leakage current each Line to Ground: 3A Models 6A Models 1.2 mA 2.3 mA .7 mA 1.2 mA @ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 V AQ 8 FS Suffix F - Fuseholder FS - Fuseholder & Switch (F & FS on VAQ8 only) Omit if none Input / Output Style 3 - Wire leads 8 - IEC inlet* (line side) Wire leads (load side) 2250 VDC 1450 VDC 3 or 6A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics 3A Models LINE LOAD 6A Models AQ Series LINE LOAD Leakage current designation V - Standard Current Rating 3 or 6A Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Available Part Numbers 3VAQ3 3VAQ8F 3VAQ8FS 6VAQ3 6VAQ8F 6VAQ8FS *IEC 60320-1 C14 inlet mates with C13 connector 12 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Frequency Power Line Filter or Power Entry Module (continued) AQ Series Case Styles and Dimensions 3VAQ3 6VAQ3 2.46 62.3 .515 13.08 1 2.572 C L 65.3 12.0 Min. 304.8 .515 13.08 #6-32 1.0 0.1 25.4 .25 #6-32 5.126 130.0 5.327.015 135.3 12.0 Min. 304.8 (5 places) #6-32 (2 places) #6-32 Thd. .5 .01 12.7 .25 (2 x) 3.061 77.8 2.0 .01 50.8 .25 .78 19.8 .50 .02 12.7 .5 3VAQ8F 6VAQ8F 6.457 164 5.68 .01 44.3 .25 4.0 .01 102 .25 5.96 152.0 5.06 .015 128.6 .38 2.35 .015 59.6 .38 .90 22.9 1.58 .015 40 .38 12.0 Min. 305.0 .958 24.3 2.48 63.0 .355 ref 9.02 #6-32 (6) inserts .411 ref 10.4 2.328 .01 59 .35 1.125 .01 3.062 28.6 .25 77.8 #6-32 (6) inserts .354 .010 ref 8.99 .25 2.576 65.4 .375 .125 9.53 3.2 .375 .125 9.53 3.2 3VAQ8FS 6VAQ8FS 5.39 .015 136.9 .38 2.35 .015 59.6 .38 1.058 26.9 .172 4.37 #6-32 (6) inserts .44 11.2 1.575 .015 40.01 .38 .958 24.3 #6-32 (6) inserts .411 ref 10.4 1.62 41.2 12.0 Min. 305.0 6.30 160.0 .391 .01 9.93 .25 12.0 Min. 305.0 1.62 41.2 .375 .125 9.53 3.2 RFI Power Line Filters 4.14 105.1 4.36 .015 111.4 .38 1.98 40.1 1.66 .015 42.1 .38 CL 2.48 63.0 7.125 181.0 6.347 .015 161.2 .38 4.0 .015 101.55 .25 2.33 .015 59.0 .38 .364 9.25 12.0 Min. 304.8 1.52 .01 3.07 38.5 .25 77.8 1.12 .01 28.3 .25 .391 .01 9.93 .25 2.58 65.4 .375 .125 9.53 3.2 13 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Frequency Power Line Filter or Power Entry Module (continued) AQ Series Recommended Panel Cutouts .910 .005 23.11 .13 .855 .005 21.72 .13 .235 .005 R 5.969 .13 .620 .005 15.75 .13 1.295 .005 32.89 .13 .620 .005 Dia. 15.75 .13 Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3VAQ 6VAQ db db 100 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 0 100 1000 Frequency in MHz 0.01 0.1 1 10 100 1000 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 14 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Filters for High Impedance Loads at Low Current B Series UL Recognized CSA Certified VDE Approved 1 VB6 B Series RFI Power Line Filters VB1 / EB1 VB3 / EB3 Specifications * Small size & low cost Maximum leakage current each Line to Ground: * General purpose @ 120 VAC 60 Hz: @250 VAC 50 Hz: * Wide variety of termination options * Meets low leakage current requirements of VDE portable equipment and non-patient medical equipment Ordering Information VB Models EB Models .4 mA .7 mA .21 mA .36 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 E B 1 Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 1 to 30A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 B Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 1, 2, 3, 5, 10, 20 or 30A Electrical Schematic LINE LOAD Available Part Numbers 1VB1 1VB3 2VB1 2VB3 3VB1 3VB3 5VB1 5VB3 10VB1 10VB3 10VB6 20VB1 20VB6 30VB6 1EB1 1EB3 2EB1 2EB3 3EB1 3EB3 5EB1 5EB3 10EB1 10EB3 20EB1 15 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Filters for High Impedance/ Low Current (continued) B Series Case Styles B1 30VB6 E E D B D B 2.00 50.8 A C A B3 C Case Dimensions Part No. Blue Blue Green/Yellow E D B Brown Brown A C 10VB6 & 20VB6 E D B A A B C 10VB1, 10EB1 10VB3, 10EB3 10VB6 20VB1, 20EB1 20VB6 30VB6 1VB1, 1EB1, 2VB1, 2EB1 1VB3, 1EB3, 2VB3, 2EB3 3VB1, 3EB1, 5VB1, 5EB1 3VB3, 3EB3, 5VB3, 5EB3 D E C 16 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Filters for High Impedance/ Low Current (continued) B Series Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 2EB, 5EB & 10EB 20EB db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 0 10 30 Frequency in MHz 10 0.1 1 10 30 Frequency in MHz 0 0.1 1VB 2VB 3VB db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 0.1 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 0.1 20VB 30VB db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 10VB 0.1 1 RFI Power Line Filters 1EB & 3EB 10 0.1 1 10 30 Frequency in MHz 0 0.1 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) 17 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Enhanced Differential Mode Performance K Series RFI Line Filters DK Series DK3 UL Recognized CSA Certified VDE Approved DK1 DK6 DK Series Specifications * Higher performance Line to Line attenuation than the K Series * E version meets the low leakage current requirements of VDE portable equipment and non-patient care equipment * V version features same high performance with more cost-effective design Ordering Information Maximum leakage current each Line to Ground: VDK Models EDK Models .4 mA .7 mA .22 mA .38 mA @ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 E DK 3 Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 1 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 DK Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 1, 3, 6, 10, or 20A Electrical Schematic LINE LOAD Available Part Numbers 1VDK1 1VDK3 3VDK1 3VDK3 6VDK1 6VDK3 10VDK1 10VDK3 20VDK1 20VDK6 1EDK1 1EDK3 3EDK1 3EDK3 6EDK1 6EDK3 10EDK1 10EDK3 20EDK1 18 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Enhanced Differential Mode K Series RFI Power Line Filters (continued) DK Series Case Styles VDK1 / EDK1 20VDK6 E 1 C D D RFI Power Line Filters E B B A A C VDK3 / EDK3 E D C Blue Case Dimensions Brown B Brown Green/ Yellow A 20VDK1 / 20EDK1 E D B B C 1VDK3, 1EDK3 3VDK1, 3EDK1, 6VDK1, 6EDK1 3VDK3, 3EDK3, 6VDK3, 6EDK3 10VDK1, 10EDK1 10VDK3, 10EDK3 20VDK1, 20EDK1 20VDK6 1VDK1, 1EDK1 D E C A A Part No. Blue 19 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Enhanced Differential Mode K Series RFI Power Line Filters (continued) DK Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1 & 3VDK 6, 10, 20VDK 1 & 3EDK 6, 10, 20EDK db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 20 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide PC Board Mountable General Purpose RFI Filters EBP, EDP & EOP Series UL Recognized* CSA Certified* VDE Approved* 1 1EDP / 1EOP RFI Power Line Filters 1EBP EBP Series Specifications * General purpose * Low leakage current * Cost-effective * Compact size Maximum leakage current each Line to Ground: EDP/EOP EBP @ 120 VAC 60 Hz: .22 mA .13 mA @250 VAC 50 Hz: .38 mA .21 mA Hipot rating (one minute): Line to Ground: Line to Line: EDP Series 2250 VDC 1450 VDC * Enhanced differential mode performance Rated Voltage (max): 250 VAC * Low leakage current Operating Frequency: 50/60 Hz * Cost-effective Rated Current: EOP Series * General purpose * Low leakage current * Cost-effective Ordering Information 1 to 10A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic EBP LINE LOAD 6 EDP EBP Series Compact Size EDP & EOP EDP Series Enhanced Performance LINE LOAD EOP Series General Performance Current Rating 1, 3, 6 or 10A *EBP models are approved to VDE standards only Available Part Numbers 1EBP 1EDP 3EDP 6EDP 10EDP 3EBP 1EOP 3EOP 6EOP 10EOP 21 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide PC Board Mountable General Purpose RFI Filters (continued) EBP, EDP, EOP Series Case Styles EBP Case Dimensions A Part No. EBP C EDP .35 Max. 8.97 EOP A B C LINE .787 20.00 B .394 10.00 LOAD .098 2.5 .590 15.0 .098 2.5 Performance Data Typical Insertion Loss EDP / EOP A Measured in closed 50 Ohm system C .35 Max. 8.97 LINE LOAD .31 .02 7.87 .5 .591 .006 15.00 .15 B 1EBP 3EBP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz .295 .006 7.50 .15 .689 .006 17.50 .15 .36 .02 9.10 .5 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 22 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide PC Board Mountable General Purpose RFI Filters (continued) EBP, EDP & EOP Series Performance Data (continued) Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 3EDP 6EDP 10EDP db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1EOP 3EOP 6EOP 10EOP db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 1 RFI Power Line Filters 1EDP 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 1 0 10 30 Frequency in MHz 0.1 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 23 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact and Cost-effective Dual Stage RFI Power Line Filters EMC Series UL Recognized CSA Certified VDE Approved EMC6 EMC1 EMC Series Specifications * Compact dual stage filter series Maximum leakage current each Line to Ground: * Cost-effective design * Current rating up to 30A @ 120 VAC 60 Hz: @250 VAC 50 Hz: 3, 6, 10A 15, 20, 30A .21 mA .43 mA .73 mA 1.52 mA * High differential mode attenuation in the lower frequency range Hipot rating (one minute): Line to Ground: Line to Line: * High common mode performance Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz * Suitable for switching mode power supplies Rated Current: 2250 VDC 1450 VDC 3 to 30A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information Electrical Schematic 10 EMC 1 LINE LOAD Case Styles 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt EMC Series Current Rating 3, 6, 10, 15, 20 or 30A Available Part Numbers 3EMC1 6EMC1 10EMC1 15EMC1 20EMC1 3EMC3 6EMC3 10EMC3 15EMC3 10EMC6 15EMC6 20EMC6 30EMC6 24 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact and Cost-effective Dual Stage RFI Power Line Filters (continued) EMC Series Case Styles EMC1 30EMC6 1 B D RFI Power Line Filters E B C D E A A C Case Dimensions EMC3 Part No. Green/ Yellow Brown 3EMC1 Brown B 6EMC1 Blue Blue 10EMC1 A D E C 15EMC1 20EMC1 3EMC3 6EMC3 EMC6 10EMC3 15EMC3 B 10EMC6 15EMC6 20EMC6 D E A C 30EMC6 A B C D E 25 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact and Cost-effective Dual Stage RFI Power Line Filters (continued) EMC Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3EMC 6EMC 10EMC 15EMC db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 20EMC 30EMC db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 10 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 26 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Stage RFI Power Line Filters for Switching Mode Power Supplies EP / VP Series UL Recognized CSA Certified VDE Approved EP7 / VP7 1 EP1 / VP1 RFI Power Line Filters EP3 / VP3 EP & VP Series Specifications * Dual stage filter offers high insertion loss * Well suited for meeting CISPR 22 A and FCC Part 15J, Class B * EP model meets very low leakage current requirements * 7A and 12A versions offer optimum package size Ordering Information 3 EP 7 M Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: @250 VAC 50 Hz: VP Models EP Models .73 mA 1.27 mA .21 mA .36 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Suffix M - Metric inserts (style 7 only) Omit for standard or none Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals (load side) EP / VP Series EP - Low leakage (<0.5 mA) VP - Standard (20A only) 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 3EP1 3EP3 3EP7 3EP7M 6EP1 6EP3 7EP1 7EP3 10EP1 10EP3 12EP1 12EP3 20EP1 20EP6 20VP1 20VP6 Current Rating 3, 6, 7, 10, 12 or 20A Accessories Electrical Schematic LINE GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord LOAD *IEC 60320-1 C14 inlet mates with C13 connector 27 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Stage RFI Filters for Switching Power Supplies (continued) EP / VP Series Case Styles EP1 / VP1 (1-15A) EP7 & EP7M Tapped insert B D B D E A A C E C 20EP1 / VP1 20EP6 / VP6 B B D E A D E A C C Recommended Panel Cutout EP3 E D Brown .235 R 5.96 C .157 Dia. (2) 3.98 .910 23.11 Brown Blue Blue A B Green/ Yellow 1.295 32.89 1.575 40.01 28 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Stage RFI Filters for Switching Power Supplies (continued) EP / VP Series Case Dimensions Part No. 3EP1 3EP3 6EP1 6EP3 7EP1 7EP3 10EP1 10EP3 12EP1 12EP3 20EP1/VP1 20EP6/VP6 B C D E Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3EP 6EP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 (continued) 12EP 20EP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 20VP db 100 90 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 80 70 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 0.01 0.1 1 10 30 Frequency in MHz 7EP 10EP db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 RFI Power Line Filters 3EP7/7M Typical Insertion Loss A 0.01 0.1 1 10 30 Frequency in MHz 29 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Single Phase Power Line Filter for Frequency Converters FC Series UL Recognized FC Series Specifications * Designed for frequency inverters and variable speed motor drives * Suitable for electronically noisy environments * Protects programmable logic controllers from RF noise on the AC power line * Side flanges for easy mounting * Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications Maximum leakage current each Line to Ground: B suffix no suffix @ 120 VAC 60 Hz: 3.9 mA 3.8 mA @250 VAC 50 Hz: 7.0 mA 6.7 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 6 to 50A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 36 FC 10 B Suffix B - Single stage Omit for dual stage Input / Output Style 10 - DIN type terminal block Electrical Schematics FC10 LINE LOAD 1 2 FC Series 1 Current Rating 6, 12, 16, 25, 36 or 50A FC10B Available Part Numbers 6FC10 12FC10 16FC10 25FC10 36FC10 50FC10 LINE LOAD 12FC10B 16FC10B 25FC10B 36FC10B 50FC10B 30 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Single Phase Filter for Frequency Converters (continued) FC Series Case Styles Case Dimensions Part No. FC10 / FC10B (6, 12, 16A) A B C D E F 1 12FC10/10B 16FC10/10B 25, 36, 50 FC10/10B 6FC10 D B F E A This hole indicates the "Line" side and may be on either flange. RFI Power Line Filters C FC10 / FC10B (25, 36, 50A ) This hole indicates the "Line" side and may be on either flange. D B C F E A 31 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Single Phase Filter for Frequency Converters (continued) FC Series Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 6FC10 12FC10 16FC10 db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 25FC10 36, 50FC10 12, 16FC10B db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 36FC10B 50FC10B db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 0.1 1 10 30 Frequency in MHz 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.01 25FC10B 0.01 1 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 32 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Differential Mode Filter for Fluorescent Lighting Applications FL Series 1 UL Listed RFI Power Line Filters FL Series Specifications * Specifically designed for fluorescent lights * Suitable for industrial environments * UL Listed for aftermarket installation Maximum leakage current each Line to Ground: @ 125 VAC 60 Hz: 3.0 mA @280 VAC 50 Hz: 6.0 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage: 1560 VAC 1560 VAC 125/280 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 3 FL 3 Input / Output Style 3 - Wire leads 3.9 A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic FL Series LINE LOAD Current Rating 3 - 3.9A Available Part Number 3FL3 33 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Differential Mode Filter for Fluorescent Lighting Applications (continued) FL Series Case Styles Case Dimensions A B C Part No. D C Load 3FL3 0.44 11.18 D E B Line 0.44 7.0 177.8 Min. (4 Wires) E Strip 0.50 12.7 (Typ) A 18 AWG (4X) Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3FL3 db 100 90 80 70 Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Differential Mode / Symmetrical (Line to Line) 34 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies G Series UL Recognized CSA Certified VDE Approved 1 10EG1 / 10VG1 RFI Power Line Filters 6EG1 / 6VG1 G Series Specifications * Designed to provide excellent attenuation for most digital electronics equipment * Broad frequency range of performance from 20kHz to 30MHz * Size and cost-effective solution * Designed to help comply with EN55022 Level A and FCC Part 15J Class B Maximum leakage current each Line to Ground: EG Models VG Models .30 mA .50 mA 1.2 mA 2.0 mA @ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 10 E G 1 Input / Output Style 1 - .250 [6.3] spade terminals 2250 VDC 1450 VDC 6 & 10A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 G Series Electrical Schematics Leakage current designation E - Low leakage (<0.5 mA) V - Standard 6EG1 & 6VG1 LINE LOAD Current Rating 6 or 10A Available Part Numbers 6EG1 10EG1 10EG1 & 10VG1 6VG1 10VG1 LINE LOAD 35 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) G Series Case Styles Case Dimensions Part No. 6EG1/VG1 B 10EG1/VG1 D E A A B C D E C Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 6EG1 6VG1 10EG1 10VG1 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 1 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 36 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Highest Performance RFI Filters for Medical Equipment HQ Series 3EHQ3 UL Recognized CSA Certified VDE Approved 1 6EHQ8 RFI Power Line Filters 3EHQ1 HQ Series Specifications * Designed to provide the highest available attenuation of RFI noise in the frequency range from 10kHz to 30MHz for low leakage current applications * Size and cost-effective Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 3 & 6A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 6 E HQ 8 M Suffix M - Metric inserts (style 8 only) Omit for standard or none Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 8 - IEC inlet* (line side) Wire leads (load side) HQ Series Available Part Numbers 3EHQ1 3EHQ3 3EHQ8 3EHQ8M 6EHQ1 6EHQ3 6EHQ8 3EHQ8M Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Leakage current designation E - Low leakage (<0.5 mA) Current Rating 3 or 6A *IEC 60320-1 C14 inlet mates with C13 connector 37 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Highest Performance RFI Filters for Medical Equipment (continued) HQ Series Electrical Schematics 3EHQ8 & 3EHQ8M Tapped insert 3EHQ Brown LOAD LINE Grn/Yel D B Blue A E C 6EHQ LOAD LINE Case Styles HQ1 6EHQ8 & 6EHQ8M Tapped inserts 3A Models C B D E A 0.63 Ref 16.0 D E C A 6A Models Grn/Yel B Blue C Brown B HQ3 3A Models Blue Blue Blue Grn/Yel B Grn/Yel Brown Brown Brown A D E C 6A Models Blue B Grn/Yel Brown C 38 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Highest Performance RFI Filters for Medical Equipment (continued) HQ Series Recommended Panel Cutout .235 R 5.96 Case Dimensions Part No. .157 Dia. (2) 3.98 3EHQ1 .910 23.11 3EHQ3 3EHQ8, 3EHQ8M 6EHQ1 6EHQ3 6EHQ8, 6EHQ8M B C D E 1 RFI Power Line Filters 1.295 32.89 1.575 40.01 A Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3EHQ 6EHQ db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 39 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Power Line Filters for Medical Equipment HT Series 6EHT3 UL Recognized CSA Certified VDE Approved 6EHT7 6EHT1 HT Series Specifications * Designed to provide significant attenuation of RFI noise in the frequency range from 10kHz to 30MHz * Size and cost-effective Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 3 to 15A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 6 E HT 7 M Available Part Numbers Suffix M - Metric inserts (style 7 only) Omit for standard or none Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals (load side) HT Series 3EHT1 3EHT3 3EHT7 3EHT7M 6EHT1 6EHT3 6EHT7 6EHT7M 10EHT1 10EHT3 15EHT1 15EHT6 Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Leakage current designation E - Low leakage (<0.5 mA) Current Rating 3, 6, 10 or 15A *IEC 60320-1 C14 inlet mates with C13 connector 40 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Line Filters for Medical Equipment (continued) HT Series Electrical Schematics 3 & 6EHT LINE HT3 LOAD Blue Blue 1 Green/Yellow B Brown Brown LINE A D LOAD RFI Power Line Filters 10EHT C E 15EHT LINE LOAD HT6 Case Styles HT1 (3, 6, 10A) E D B E B 2.00 0.01 50.80 0.25 A C D A C HT7 & HT7M HT1 (15A) D B E D B E C A 2.00 0.01 50.80 0.25 C A 41 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Line Filters for Medical Equipment (continued) HT Series Recommended Panel Cutout Case Dimensions Part No. 1.575 40.01 0.235 R 5.96 3EHT1, 6EHT1 3EHT3, 6EHT3 3EHT7 / 7M, 6EHT7 / 7M 0.910 23.1 0.157 Dia. 3.98 1.295 32.89 10EHT1 10EHT3 15EHT1 15EHT6 A B C D E Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 3EHT 6EHT 10EHT 15EHT db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 1 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 42 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Line Filter for Medical Applications HZ Series UL Recognized CSA Certified VDE Approved 1 RFI Power Line Filters HZ Series Specifications * Designed to provide good attenuation to RFI noise in the frequency range from 10kHz to 30MHz * Size and cost-effective Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A Hipot rating (one minute): Line to Ground: Line to Line: * Low leakage current * New versions up to 30A Ordering Information 3 E HZ 1 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Input / Output Style 1 - .250 [6.3] spade terminals 6 - Threaded bolt HZ Series Leakage current designation E - Low leakage (<0.5 mA) Current Rating 3, 4, 6, 10, 15, 20 or 30A 3 to 30A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Case Styles 3EHZ1 Available Part Numbers B 3EHZ1 6EHZ1 15EHZ1 30EHZ6 4EHZ1 10EHZ1 20EHZ1 D E A C Electrical Schematic LINE LOAD 43 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Line Filter for Medical Applications (continued) HZ Series Case Styles (continued) 30EHZ6 4EHZ1 B B D E A C D E A C 6EHZ1 B Case Dimensions C D E A Part No. 3EHZ1 10, 15 & 20EHZ1 4EHZ1 6EHZ1 10EHZ1 15EHZ1 20EHZ1 B 30EHZ6 C A B C D E D E A 44 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Line Filter for Medical Applications (continued) Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3EHZ1 4EHZ1 6EHZ1 db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 0.1 1 10 30 Frequency in MHz 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 10EHZ1 15EHZ1 20EHZ1 db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 0.01 0.1 1 10 30 Frequency in MHz RFI Power Line Filters 0.01 1 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 30EHZ6 db 100 90 80 70 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 45 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Single and 2-phase RFI Filters for Industrial Applications IK Series IK Series Specifications * Excellent performance for applications with high interference levels * Designed for single or two-phase applications * Wide current range * For small to medium sized industrial equipment, power converters and variable speed motors * Touch safe terminals on the 6 to 60A product provide easy connections and prevent inadvertent contact for safety in the most demanding applications Ordering Information 1 IK 1 C Suffix C - Ground Choke Maximum leakage current each Line to Ground: @120 VAC 60 Hz: 1IK & 6IK: 0.6 mA 16, 35 & 50IK: 1.7 mA 80IK: 5.2 mA @289 VAC 50 Hz: 1IK: 1.2 mA @277 VAC 50 Hz: 6IK: 1.15 mA 16, 35 & 50IK: 3.2 mA 80IK: 9.9 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): Line to Ground: Line to Line: (1IK1C only) Operating Frequency: Rated Current: Input / Output Style 1 - .250 [6.3] spade terminals 10 - DIN type terminal block 16 & 35IK: DIN input / Wire leads output 50 & 80IK: DIN input / DIN output 2250 VDC 1450 VDC 1IK 289 VAC 277 VAC 6 to 80IK 500 VAC 480 VAC 50/60 Hz 1 to 80A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 IK Series Electrical Schematic Current Rating 1, 6, 16, 35, 50 & 80A LINE LOAD 2 Available Part Number 1IK1C 16IK10 50IK10 6IK1 35IK10 80IK10 1 2 46 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Single and 2-phase RFI Filters for Industrial Applications IK Series Case Styles 1IK1C 16 & 35IK10 1 C D E A RFI Power Line Filters B C A F Black B 1.49 38.0 Brown E 6IK1 D B 50 & 80IK10 D E A C C A F B 2.36 60.0 E D 47 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Single and 2-phase RFI Filters for Industrial Applications IK Series Case Dimensions Part No. 1IK1C 6IK1 16IK10 35IK10 50IK10 80IK10 A B C D E F Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1IK1C 6IK1 db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.1 1 16 & 35IK10 50 & 80IK10 db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 48 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Power Line Filters - Ideal for High Impedance Load K Series UL Recognized CSA Certified VDE Approved** VK6 VK7 / EK7 1 RFI Power Line Filters VK1 / EK1 VK3 / EK3 K Series Specifications * Suitable for high impedance loads * Well suited to applications where pulsed, continuous and/or intermittent RFI interference is present Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: @250 VAC 50 Hz: VK Models EK Models .5 mA 1.0 mA .21 mA .36 mA * EK models meet the very low leakage current requirements for VDE portable equipment and non-patient care medical equipment Hipot rating (one minute): Line to Ground: Line to Line: * Available with ground line inductor (choke) Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 1 to 60A* Ordering Information 10 E K 7 M Suffix M - Metric inserts (style 7 only) Omit for standard or none C - Ground choke (30, 40VK6 only) Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals (load side) K Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 1, 2, 3, 5, 10, 20, 30, 40 or 60A *1-15A: IEC 60320-1 C14 inlet mates with C13 connector 20VK7: C20 inlet mates with C19 connector 2250 VDC 1450 VDC Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 1VK1 1VK3 2VK1 2VK3 3VK1 3VK3 3VK7 3VK7M 5VK1 5VK3 5VK7 5VK7M 10VK1 10VK3 10VK6 10VK7 10VK7M 20VK1 20VK6 20VK7* 30VK6 30VK6C 40VK6 40VK6C 60VK6 1EK1 1EK3 2EK1 2EK3 3EK1 3EK3 3EK7 3EK7M 5EK1 5EK3 5EK7 5EK7M 10EK1 10EK3 10EK7 10EK7M 20EK1 **20VK7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC 49 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Power Line Filters (continued) K Series Electrical Schematics LINE LOAD Case Styles K1 (1, 2, 3, 6, 10A) E D B 30 & 40VK6C LINE (Inductor in Ground Line) LOAD 60VK6 A C K1 (20A) LINE LOAD E D B Accessories A GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord C K3 Blue Blue Green/Yellow E D B Brown Brown 20VK7 A C 20VK6 VK1/EK1 50 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Power Line Filters (continued) K Series Case Styles (continued) 10VK6 60VK6 1 E D B E D B C 20VK6 C A RFI Power Line Filters 2.00 50.8 A K7 & K7M (3, 5, 10A) Tapped insert D E D B A B E C A C 30VK6/6C & 40VK6/6C Terminal on 30VK6C and 40VK6C only 20VK7 E E D B A D B 2.65 .016 67.31 .40 C 2.00 50.8 A .669 .010 16.99 .25 .512 .010 13.00 .25 C 51 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Power Line Filters (continued) K Series Case Dimensions Part No. 1VK1, 1EK1, 2VK1, 2EK1 1VK3, 1EK3, 2VK3, 2EK3 3VK1, 3EK1, 5VK1, 5EK1 3VK3, 3EK3, 5VK5, 5EK3 3VK7/7M, 3EK7/7M 5VK7/7M, 5EK7/7M 10VK1, 10EK1 10VK3, 10EK3 10VK6 10VK7/7M, 10EK7/7M 20VK1, 20EK1 20VK6 20VK7 30VK6, 30VK6C 40VK6, 40VK6C 60VK6 Recommended Panel Cutouts A B C D E K7 & K7M Cutout (3, 5, 10A) .235 R 5.96 .157 Dia. 3.98 .910 23.1 1.295 32.89 1.575 40.01 20VK7 Cutout .157 Dia. 4.0 R .062 1.60 1.46 37.1 1.145 29.1 D Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1 & 3EK 2 & 10EK db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 5EK 20EK db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 1 10 30 Frequency in MHz 0 0.1 52 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide General Purpose RFI Power Line Filters (continued) K Series Performance Data (continued) Typical Insertion Loss Measured in closed 50 Ohm system 1VK 2VK 3VK 5VK db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 20VK 30VK & 30VK6C db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 30 30 30 20 20 20 10 10 0 0.1 1 0 10 30 Frequency in MHz 1 60VK db 100 db 100 90 90 80 80 70 60 60 50 50 40 40 30 30 20 20 1 10 30 Frequency in MHz 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 10 0 0.1 10 0.1 40VK & 40VK6C 70 0 10 30 Frequency in MHz 10VK 40 RFI Power Line Filters 50 40 0 1 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 53 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multi-purpose Medical Filter for Power Line Noise Protection MV Series UL Recognized CSA Certified VDE Approved MV Series Specifications * Multi-purpose medical filter * Improved Line to Ground performance * A good solution to emission or immunity problems * Meets leakage current requirements of UL2601 for health care equipment Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .07 mA @250 VAC 50 Hz: .13 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information Electrical Schematic 6 MV 1 Input / Output Style 1 - .250 [6.3] spade terminals LINE LOAD MV Series Current Rating 3, 6, 10 or 20A Available Part Numbers 3MV1 10MV1 6MV1 20MV1 54 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multi-purpose Medical Filter for Power Line Noise Protection (continued) MV Series Case Styles MV1 (3, 6, 10A) Performance Data Typical Insertion Loss Measured in closed 50 Ohm system B C 6MV db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 20MV1 10 0.1 1 0 10 30 Frequency in MHz 20MV db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 E 0.1 10MV 0 1 RFI Power Line Filters D E A 3MV 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 1 0 10 30 Frequency in MHz 0.1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) D B Minimum Insertion Loss Measured in closed 50 Ohm system 2.00 Common Mode / Asymmetrical (Line to Ground) 50.8 A C Case Dimensions Part No. 3MV1 6MV1 10MV1 20MV1 A B C D E Differential Mode / Symmetrical (Line to Line) 55 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies N Series UL Recognized CSA Certified VDE Approved 6VN1 10VN1 N Series Specifications * Superior attenuation for most digital electronic equipment over the frequency range of 10kHz to 30MHz Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 1.2 mA @250 VAC 50 Hz: 2.0 mA * Provides excellent common mode and differential mode performance Hipot rating (one minute): Line to Ground: Line to Line: * Cost-effective solution to very noisy equipment that must meet conducted emission limits 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 6 to 10A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 10 V N 1 Electrical Schematics Input / Output Style 1 - .250 [6.3] spade terminals 3VN N Series LINE LOAD Leakage current designation V - Standard Current Rating 6 or 10A 10VN Available Part Numbers 6VN1 LINE LOAD 10VN1 56 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) N Series Case Styles Performance Data Typical Insertion Loss Measured in closed 50 Ohm system B C 10VN1 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 0 1 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Case Dimensions 6VN1 db 100 10 Part No. 10VN db 100 RFI Power Line Filters D E A 6VN Minimum Insertion Loss A B C D E Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 57 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Highest Performance RFI Filters for Switching Power Supplies Q Series Q8 UL Recognized CSA Certified VDE Approved Q1 Q Series Q3 Specifications * Specifically developed for switching power supplies * High attenuation for common and differential mode interference * Effective from 10kHz to 30MHz * Optimized for attenuation and size * 3 or 6A versions available with IEC inlet Ordering Information 6EQ8M Suffix M - Metric inserts (style 8 only) Omit for standard or none Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 8 - IEC inlet* (line side) Wire leads (load side) Q Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 3, 6 or 20A Maximum leakage current each Line to Ground: 3 & 20A VQ Models EQ Models @120 VAC 60 Hz: .73 mA .22 mA @250 VAC 50 Hz: 1.27 mA .38 mA 6A @120 VAC 60 Hz: -- .29 mA @250 VAC 50 Hz: -- .51 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 3EQ1 3EQ3 3EQ8 3EQ8M 6EQ1 6EQ3 6EQ8 6EQ8M 20EQ1 3VQ1 3VQ3 3VQ8 3VQ8M 20VQ1 Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord *IEC 60320-1 C14 inlet mates with C13 connector 58 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Highest Performance RFI Filters for Switching Power Supplies (continued) Q Series Electrical Schematics 3A Q8, Q8M (3A) Tapped insert Brown LINE LOAD 1 Grn/Yel D B Blue A E C RFI Power Line Filters 6, 20A LINE LOAD Q8, Q8M (6A) Case Styles Q1 Tapped insert 3, 20A Models C Grn/Yel B Blue 0.63 Ref 16.0 Brown .313 Ref 7.95 D E A B C D E A 6A Models B C Case Dimensions Part No. Q3 3VQ1, 3EQ1 3A Models Blue Blue Blue Grn/Yel B Grn/Yel 3VQ3, 3EQ3 Brown Brown Brown A D E 3VQ8/8M, 3EQ8/8M C 6A Models 6EQ1 Blue B Grn/Yel Brown C 6EQ3 6EQ8/8M 20EQ1, 20VQ1 A B C D E 59 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Highest Performance RFI Filters for Switching Power Supplies (continued) Q Series Recommended Panel Cutout .235 R 5.96 .157 Dia. (2) 3.98 .910 23.11 1.295 32.89 1.575 40.01 Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3VQ 3EQ 6EQ 20VQ db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 20EQ db 100 90 80 70 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 60 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Two-stage General Purpose RFI Power Line Filter R Series VR7/7M UL Recognized CSA Certified VDE Approved 1 VR3/ER3 RFI Power Line Filters 10VR6 VR1/ER1 R Series Specifications * Dual T section RFI filter provides premium performance * Well suited for low impedance loads where noisy RFI environments are present Maximum leakage current each Line to Ground: VR Models ER Models @120 VAC 60 Hz: .4 mA .21 mA @250 VAC 50 Hz: .7 mA .36 mA * Controls pulsed, continuous and/or intermittent interference Hipot rating (one minute): Line to Ground: Line to Line: * ER models offer low leakage current without deterioration of insertion loss Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz 2250 VDC 1450 VDC Rated Current: Ordering Information 10E R 7 M Suffix M - Metric inserts (style 8 only) Omit for standard or none C - Ground choke (select models) Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals (load side) R Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 1, 2, 3, 5, 10 or 20A *IEC 60320-1 C14 inlet mates with C13 connector 1 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 1VR1 1VR3 2VR1 2VR3 3VR1 3VR3 3VR7 3VR7M 5VR1 5VR3 5VR7 5VR7M 10VR1 10VR3 10VR6 10VR7 10VR7M 20VR1 20VR6 1ER1 1ER3 2ER1 2ER3 3ER1 3ER3 3ER7 3ER7M 5ER1 5ER3 5ER7 5ER7M 10ER1 10ER3 10ER7 10ER7M 20ER1 61 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Two-stage General Purpose RFI Power Line Filter (continued) R Series Electrical Schematic Case Styles (continued) R3 LINE LOAD Blue Blue B Brown Brown A D E Green/ Yellow C Case Styles R1 (1, 2, 3, 5, 10A) 10VR6 B B D E A D E A C R1 (20A) E C 20VR6 D B E D B 2.00 2.00 50.8 50.8 A C A C 62 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Two-stage General Purpose RFI Power Line Filter (continued) R Series Case Styles (continued) R7 & R7M Case Dimensions Part No. Tapped insert D B E C Recommended Panel Cutout .235 R 5.96 .157 Dia. (2) 3.98 .910 23.11 1.295 32.89 1.575 40.01 B C 1VR1, 1ER1, 2VR1, 2ER1 1VR3, 1ER1, 2VR3, 2ER3 3VR1, 3ER1, 5VR1, 5ER1 3VR3, 3ER3, 5VR3, 5ER3 3VR7/7M, 3ER7/7M 5VR7/7M, 5ER7/7M 10VR1, 10ER1 10VR3, 10ER3 10VR6 10VR7/7M, 10ER7/7M 20VR1, 20ER1 20VR6 D E 1 RFI Power Line Filters A A Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord 63 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Two-stage General Purpose RFI Power Line Filter (continued) R Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1ER 3ER 5ER 2ER, 10ER & 20ER db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1VR 2VR 3VR 5VR db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10VR 20VR db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 30 Frequency in MHz 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 1 0 10 30 Frequency in MHz 0.1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 64 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Compact Power Line Filter RK Series UL Recognized CSA Certified VDE Approved 1 RFI Power Line Filters RK Series Specifications Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 0.16 mA @250 VAC 50 Hz: 0.26 mA * Compact * Single stage * Chassis mount * Significant differential mode performance * Suitable for industrial machinery * Low input leakage current makes it suitable for portable equipment Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 10 E RK 1 Input / Output Style 1 - .250 [6.3] spade terminals Electrical Schematic RK Series Leakage current designation E - Low leakage (<0.5 mA) LINE LOAD Current Rating 3, 6, 10, 15 or 20A Available Part Numbers 3ERK1 10ERK1 20ERK1 6ERK1 15ERK1 65 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Compact Power Line Filter (continued) RK Series Case Styles Case Dimensions Part No. RK1 (3 & 6A) B C 6ERK1 10ERK1, 15ERK1, 20ERK1 3ERK1 A E D C A D E B RK1 (10, 15 & 20A) A E D C B 66 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Compact Power Line Filter (continued) RK Series Performance Data Typical Insertion Loss 1 Measured in closed 50 Ohm system 6RK 10RK 15RK db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 RFI Power Line Filters 3RK 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 20RK db 100 90 80 70 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 67 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multipurpose Power Line RFI Filter for Emission Control S Series UL Recognized CSA Certified VDE Approved 20VS1 3VS1 S Series Specifications * Combines Line to Ground interference rejection filters with additional circuitry to reduce Line to Line noise and transients * Designed for use when equipment impedance at RF frequencies is high * Effective for use with switch-mode power supplies * Effective when used to control emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz Maximum leakage current each Line to Ground: 3 & 20A 60A @120 VAC 60 Hz: .4 mA .75 mA @250 VAC 50 Hz: .7 mA 1.25 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 60A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 20 V S 6 Input / Output Style 1 - .250 [6.3] spade terminals 6 - Threaded bolt Electrical Schematics 3, 6, 10VS LINE LOAD S Series Leakage current designation V - Standard 20VS Current Rating 3, 6, 10, 20 or 60A LINE LOAD Available Part Numbers 3VS1 6VS1 10VS1 20VS1 20VS6 60VS6 60VS LINE LOAD 68 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multipurpose Power Line RFI Filter for Emission Control (continued) S Series Case Styles S1 (3, 6, 10A) 60VS6 1 A E B C D 2.25 .01 57.15 .25 B D E A RFI Power Line Filters .415 [10.54] ref. C 1.12 ref. 28.5 Case Dimensions 20VS1 Part No. 3VS1 E D B 6VS1 10VS1 2.00 50.8 A 20VS1 C 20VS6 60VS6 A B C D E 20VS6 B D E 2.00 50.8 C A 69 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multipurpose Power Line RFI Filter for Emission Control (continued) S Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3VS 6VS 10VS 20VS db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 60VS db 100 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 90 80 70 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 70 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance B Series RFI Line Filters SB Series UL Recognized CSA Certified VDE Approved 1 20VSB1 30ESB6 RFI Power Line Filters 6VSB1 SB Series Specifications * Enhanced performance version of our popular B Series of RFI line filters * Small size with enhanced performance * 30A version half the size of other 30A filters * Low leakage version available that meets current requirements of VDE portable equipment and non-patient care medical equipment Ordering Information 20 E SB 6 Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: @250 VAC 50 Hz: VSB Models ESB Models .75 mA 1.25 mA .22 mA .36 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC 250 VDC Operating Frequency: 50/60 Hz Rated Current: Input / Output Style 1 - .250 [6.3] spade terminals 6 - Threaded bolt 2250 VDC 1450 VDC 6 to 30A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 SB Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Current Rating 6, 10, 20 or 30A Available Part Numbers 6ESB1 10ESB1 10ESB6 20ESB1 20ESB6 30ESB6 6VSB1 10VSB1 10VSB6 20VSB1 20VSB6 30VSB6 Electrical Schematic LINE LOAD 71 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance B Series RFI Line Filters (continued) SB Series Case Styles Case Dimensions Part No. 6ESB1 & 6VSB1 B D E A C 6ESB1, 6VSB1 10ESB1, 10VSB1 10ESB6, 10VSB6 20ESB1, 20VSB1 20ESB6, 20VSB6 30ESB6, 30VSB6 A B C D E 10ESB1, 10VSB1, 20ESB1 & 20VSB1 B C D E A ESB6 & VSB6 B C D E A 72 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance B Series RFI Line Filters (continued) SB Series Performance Data Typical Insertion Loss 1 Measured in closed 50 Ohm system ESB Models 10ESB1 10ESB6 20ESB1 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0.01 0.1 1 10 30 Frequency in MHz 0.01 0.1 20ESB6 30ESB6 db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 RFI Power Line Filters 6ESB1 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 VSB Models 6VSB1 10VSB1 10VSB6 20VSB1 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 20VSB6 30VSB6 db 100 db 100 90 90 80 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 73 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance B Series RFI Line Filters (continued) SB Series Performance Data (continued) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 74 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance K Series RFI Line Filters for SMPS Emission Control SK Series UL Recognized CSA Certified VDE Approved SK7/7M 1 RFI Power Line Filters SK1 SK3 SK Series Specifications * Designed to reduce conducted noise to acceptable limits for equipment that must comply with FCC / EN specifications * Utilizes significantly higher element values than the general purpose K Series which makes them better suited for equipment with Line to Ground and Line to Line conducted emissions including those with switching power supplies * ESK6C and VSK6C incorporate separate ground circuit inductor to isolate the equipment chassis from power line ground at RF frequencies Ordering Information 10 E SK 7 M Suffix M - Metric inserts (style 7 only) Omit for standard or none C - Ground choke (30ESK/VSK only) Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals (load side) SK Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard Maximum leakage current each Line to Ground: 3, 6 & 10A VSK Models ESK Models @120 VAC 60 Hz: .4 mA .21 mA @250 VAC 50 Hz: .7 mA .36 mA 20, 30 & 40A @120 VAC 60 Hz: .75 mA .3 mA @250 VAC 50 Hz: 1.25 mA .5 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 40A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 3VSK1 3VSK3 3VSK7 3VSK7M 6VSK1 6VSK3 6VSK7 6VSK7M 10VSK1 10VSK3 10VSK7 10VSK7M 3ESK1 3ESK3 3ESK7 3ESK7M 6ESK1 6ESK3 6ESK7 6ESK7M 10ESK1 10ESK3 10ESK7 10ESK7M 20ESK6 20VSK6 30ESK6 30ESK6C 30VSK6 30VSK6C 40VSK6 Current Rating 3, 6, 10, 20, 30 or 40A *IEC 60320-1 C14 inlet mates with C13 connector 75 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance K Series Filters for SMPS Emission Control (continued) SK Series Electrical Schematic LINE Case Styles SK1 LOAD B 1 D E A C Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord SK3 (3A) Blue Blue B Brown Brown A D E Green/ Yellow C SK3 (6 & 10A) Blue Blue Grn/Yel B Brown Brown ESK6 / VSK6 A D E C 76 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance K Series Filters for SMPS Emission Control (continued) SK Series Case Styles (continued) SK6 (20A) SK6 (40A) 1 D B E D B RFI Power Line Filters E A 2.00 50.5 A C SK6 (30A) C SK7 & SK7M Tapped insert D B E D B A E C 1.50 38.1 A C SK6C (30A) Recommended Panel Cutout .235 R 5.96 .157 Dia. (2) 3.98 E D B .910 23.11 1.50 38.1 A C 1.295 32.89 1.575 40.01 77 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance K Series Filters for SMPS Emission Control (continued) SK Series Case Dimensions Part No. 3VSK1, 3ESK1 3VSK3, 3ESK3 3VSK7/7M, 3ESK7/7M 6VSK1, 6ESK1 6VSK3, 6ESK3 6VSK7/7M, 6ESK7/7M 10VSK1, 10ESK1 10VSK3, 10ESK3 10VSK7/7M, 10ESK7/7M 20VSK6, 20ESK6 Part No. 30VSK6, 30ESK6 30VSK6C, 30ESK6C 40VSK6 Performance Data A B C D A B C D E E Typical Insertion Loss Measured in closed 50 Ohm system 3 & 6VSK 3 & 6ESK db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10 & 20VSK 10 & 20ESK db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 30VSK 30ESK db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 0.01 40VSK db 100 90 80 70 60 50 40 30 20 10 0 0.01 0.1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 78 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance K Series Filters for SMPS Emission Control (continued) SK Series Performance Data (continued) 1 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) RFI Power Line Filters Differential Mode / Symmetrical (Line to Line) 79 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Power Line Filters for Switching Power Supplies T Series UL Recognized CSA Certified VDE Approved T Series Specifications * Superior common-mode and premium differential-mode attenuation * Smaller package sizes than the EP Series * Size and cost-effective * ET models can help meet very low leakage current requirements Maximum leakage current each Line to Ground: 3, 6 & 10A ET Models VT Models @120 VAC 60 Hz: .30 mA .75 mA @250 VAC 50 Hz: .50 mA 1.2 mA 15 & 20A @120 VAC 60 Hz: .30 mA 1.2 mA @250 VAC 50 Hz: .50 mA 2.0 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 10 E T 1 Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire leads 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals (load side) T Series Leakage current designation E - Low leakage (<0.5 mA) V - Standard 2250 VDC 1450 VDC 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 3ET1 3ET3 3ET7 6ET1 6ET3 6ET7 10ET1 10ET3 15ET1 15ET6 20ET1 20ET6 10VT1 10VT3 15VT1 15VT6 20VT1 20VT6 Current Rating 3, 6, 10, 15 or 20A *IEC 60320-1 C14 inlet mates with C13 connector 80 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) T Series Electrical Schematics Case Styles 3 & 6A LINE T1 (3, 6, 10A) LOAD 1 B LINE LOAD RFI Power Line Filters D E A 10A C 15 & 20A LINE LOAD T1 (15 & 20A) E D B 2.00 .01 50.8 .25 Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord C A T3 Blue Blue Grn/Yel Brown B Brown A D E C 81 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) T Series Case Styles (continued) Case Dimensions T6 Part No. 3ET1, 6ET1 E D 3ET3, 6ET3 B 3ET7, 6ET7 10ET1, 10VT1 2.00 .01 50.8 .25 A C T7 10ET3, 10VT3 15ET1, 15VT1, 20ET1, 20VT1 15ET6, 15VT6, 20ET6, 20VT6 Tapped insert A B C D E D B E A C Recommended Panel Cutout .235 R 5.96 .157 Dia. 3.98 .910 23.1 1.295 32.89 1.575 40.01 82 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance RFI Filters for Switching Power Supplies (continued) T Series Performance Data Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Typical Insertion Loss 1 Measured in closed 50 Ohm system 6ET 10ET 15ET db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 20ET 10VT 15VT 20VT db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0.1 1 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 80 40 0.01 RFI Power Line Filters 3ET 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 83 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Filter for Power Factor Corrected Power Supplies U Series UL Recognized CSA Certified VDE Approved 6EU1 U Series 6EUP Specifications * Designed for equipment using power factor corrected power supplies * Offers high impedance circuit to mismatch the power supply's impedance characteristics * Available in PC board mountable version * All models meet low leakage current requirements Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .30 mA @250 VAC 50 Hz: .50 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VAC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 6A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 6EU1 Input / Output Style 1 - .250 [6.3] spade terminals P - PC board pins Electrical Schematic LINE LOAD U Series Leakage current designation E - Low leakage (<0.5 mA) Current Rating 6A Available Part Numbers 6EUP 6EU1 84 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Filter for Power Factor Corrected Power Supplies (continued) U Series Case Styles 6EU1 Case Dimensions Part No. B C 6EU1 D 1 E RFI Power Line Filters B 6EUP D E A A Performance Data C Typical Insertion Loss Measured in closed 50 Ohm system 6EUP 6EU db 100 90 80 B 70 60 50 40 30 Ground pin (2) Threaded Inserts (3) .14 3.56 20 10 0 .39 9.91 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) C A Minimum Insertion Loss Common Mode / Asymmetrical (Line to Ground) Recommended PC Board Layout LINE LOAD .157 Dia. (3) .075 Dia. (6) .26 6.60 1.50 38.1 .52 13.21 .75 19.05 Differential Mode / Symmetrical (Line to Line) 1.50 38.1 .79 20.07 2.10 53.34 2.99 75.95 85 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multipurpose Power Line RFI Filter for Emission Control V and W Series UL Recognized CSA Certified VDE Approved1 VV1 / VW1 VV6 / VW6 Both the V and W series are effective to control emissions in equipment using SCR and T2L circuits for compliance with FCC Part 15, Subpart J and EN55022, Level A, down to 150kHz V Series * Offers an N = 3 ("T") Line to Ground impedance to common mode and an N = 5 "Dbl. Pi") impedance for Line to Line differential mode interference * Designed for susceptibility use when equipment impedance at RF frequencies is low W Series * Offers an N = 4 ("Dbl. L") Line to Ground impedance for common mode and an N=5 ("Dbl. Pi") impedance for Line to Line differential mode interference * Designed for use when equipment impedance at RF frequencies is high * Two stage construction provides excellent suppression at high frequencies Ordering Information 20 V V 6 Specifications Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .5 mA @250 VAC 50 Hz: .82 mA Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 20A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics V Series LINE (load side) LOAD W Series (3, 6 & 10A) LINE Input / Output Style 1 - .250 [6.3] spade terminals 6 - Threaded bolt 7 - IEC inlet* (line side) .250 [6.3] spade terminals 2250 VDC 1450 VDC LOAD W Series (20A) LINE LOAD V or W Series Leakage current designation V - Standard Current Rating 3, 6, 10 or 20A *IEC 60320-1 C20 inlet mates with C19 connector 120VW7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC 86 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multipurpose Power Line RFI Filter for Emission Control (continued) Case Styles (continued) VW7 V and W Series Threaded inserts Available Part Numbers 3VV1 6VV1 10VV1 20VV1 20VV6 3VW1 3VW1 10VW1 20VW1 20VW6 20VW7* 2.25 57.15 B B Recommended Panel Cutout .157 3.98 Dia. 1.22 30.99 C 2.30 58.42 1.60 40.46 C L .75 19.05 Mounting Plane .219 R 5.56 V1 / W1 (20A) 2.12 53.85 Case Dimensions Part No. E D B 2.00 50.8 A C V6 / W6 E D B A B C 6VV1, 6VW1 10VV1, 10VW1 20VV1, 20VW1 20VV6, 20VW6 20VW7 3VV1, 3VW1 C A RFI Power Line Filters 5.33 .025 135.38 .635 Case Styles V1 / W1 (3, 6 & 10A) D E A 1 .047 .010 1.19 .25 D E 2.00 50.8 A C *20VW7, 20A model tested by Underwriters Laboratories to US and Canadian requirements and is VDE approved at 16A, 250VAC 87 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Multipurpose Power Line RFI Filter for Emission Control (continued) V and W Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 3VV 6VV 10VV 20VV db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 3VW 6VW 10VW 20VW db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 1 0 10 30 Frequency in MHz 0.1 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 88 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance, Low Cost Filter Ideal for Appliance Equipment WG Series UL Recognized CSA Certified VDE Approved 1 RFI Power Line Filters WG_1 Style WG Series Specifications * Cost-effective * Tubular design * WGA, WGB and WGC versions designed to comply with leakage current for fixed appliances not easily moved from one place to another * WGD, WGE and WGF versions designed to comply with leakage current requirements for appliances which may be easily moved from one place to another * Available in a variety of styles Ordering Information 16 WG A 1 Maximum leakage current each Line to Ground: A, B & C Models D, E & F Models .76 mA 1.27 mA .10 mA .20 mA @ 120 VAC 60 Hz: @250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 16A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics Input / Output Style 1 - .250 [6.3] spade terminals 3 - Wire Leads 7 - RAST 5 connection Leakage Current & Performance A, B & C: for fixed appliances A = Standard B = Enhanced C = High performance D, E & F: for mobile appliances D = Standard E = Enhanced F = High performance WG Series Current Rating 16A L (2) U (1) GND N(4) U (3) With RAST 5 Connector (style 7) L GND N Available Part Numbers 16WGA1 16WGB1 16WGC1 16WGD1 16WGE1 16WGF1 16WGA3 16WGB3 16WGC3 16WGD3 16WGE3 16WGF3 16WGA7 16WGB7 16WGC7 16WGD7 16WGE7 16WGF7 89 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance, Low Cost Filter for Appliance Equipment (continued) WG Series Case Styles WG_1 .386 9.80 WG_3 2.46 max. 62.5 .386 9.80 .46 max. 11.7 2.0 max. 50.8 4.0 min. 101.6 1.49 Dia. 37.8 WG_7 .386 9.80 2.4 max. 60.96 .352 min. 8.94 1.49 Dia. 37.8 1.49 Dia. 37.8 WG_7 Style 90 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance, Low Cost Filter for Appliance Equipment (continued) WG Series Performance Data Typical Insertion Loss 1 Measured in closed 50 Ohm system All Case Styles 16WGB 16WGC 16WGD db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 16WGE 16WGF db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 30 Frequency in MHz 0 RFI Power Line Filters 16WGA 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 91 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Chassis or PC Board Mountable Power Line Filters for Emission Control X, Y, Z Series UL Recognized CSA Certified VDE Approved XP / YP / ZP 3EX1 / 3EZ1 X, Y, Z Series * Compact chassis or PC board mountable * Three levels of performance * Complete filtering solution in minimal size X Series * Designed to bring most digital equipment (including those with switching power supplies) into compliance with FCC Part 15J, Class B conducted emission limits Y Series * Designed to bring most digital equipment (including those with switching power supplies) into compliance with EN55022, Level A and FCC Part 15J, Class B conducted emission limits Z Series Specifications Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .30 mA @250 VAC 50 Hz: .50 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 1 to 6A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic LINE LOAD * Designed to bring most digital equipment (including those with switching power supplies) into compliance with EN55022, Level B and FCC Part 15J, Class B conducted emission limits Ordering Information 3EX1 Input / Output Style 1 - .250 [6.3] spade terminals P - PC board pins X, Y or Z Series Available Part Numbers 3EXP 3EX1 4EXP 6EXP 2EYP 3EYP 4EYP 1EZP 2EZP 3EZP 3EZ1 Leakage current designation E - Low leakage (<0.5 mA) Current Rating 1, 2, 3, 4 or 6A 92 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Chassis & PC Board Mountable RFI Filters for Emission Control (continued) X, Y, Z Series Case Styles X1 & Z1 Case Dimensions Part No. 3EXP B 3EX1 C 4EXP 6EXP 2EYP 3EYP, 4EYP XP, YP & ZP 1EZP A 2EZP, 3EZP 3EZ1 B C D E 1 RFI Power Line Filters D E A A C Recommended PC Board Layout 2.660 67.56 0.123 Min. 3.12 1.850 46.99 .605 15.37 1.050 26.67 Grounds B Line side Load side .350 8.89 1.190 .700 30.23 17.78 .245 6.22 .150 3.81 93 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Chassis & PC Board Mountable RFI Filters for Emission Control (continued) X, Y, Z Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3EX 4EX 6EX db 100 db 100 db 100 90 90 90 80 80 70 70 70 60 60 60 80 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 0.01 0.1 1 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 2EY 3EY 4EY db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0 0.01 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 0.01 2EZ 3EZ db 100 db 100 db 100 90 90 90 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0.01 0.1 1 10 30 Frequency in MHz 0 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10 0.01 1EZ 0 0.1 80 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 94 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Chassis & PC Board Mountable RFI Filters for Emission Control (continued) Performance Data (Continued) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 1 RFI Power Line Filters 95 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 96 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 2. Three Phase Filters -- Table of Contents Three Phase Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .97 A Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .98 ADT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .101 AYA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .104 AYC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .108 AYO Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .111 BCF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .113 CFN Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .116 FCD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .118 2 Three Phase Selector Chart Delta or WYE NEW CFN WYE or Delta Wiring Try The Try The Series 300-600A Page 116 Three Phase Filters Delta Wiring ONLY All Series Are Listed in Ascending Performance AYO Series 3-20A Page 111 N ow to 2 30 A NEW from BCF Series 7-180A Page 113 Good to FCD Series 6-230A Page 118 AYA Series 16-100A Page 104 AYC Better to Series 16-200A Page 108 ADT A Series 3-200A Page 101 Series 20-60A Page 98 Best 97 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance 3-phase RFI Filters for WYE Applications A Series UL Recognized CSA Certified VDE Approved A Series Specifications * For 3-phase, four wire, WYE Applications * Filters each of the three lines plus the neutral and ground line * Both common mode and differential mode suppression from 50kHz to 30MHz * Effective for both balanced and unbalanced loads * Ground choke included Maximum leakage current, each Line to Ground: @ 120 VAC 60 Hz: 1.4 mA @ 250 VAC 50 Hz: 3.4 mA Hipot rating (one minute): Line to Ground: Neutral to Ground: Line to Neutral: 1500 VAC 1500 VAC 1450 VDC * Optional end bell kits available to shield input and output terminals Rated Voltage (max): Phase to Phase: Phase to Neutral / Ground: 440 VAC 250 VAC * AYP single stage for lower noise environments Operating Frequency: 50/60 Hz * AYT dual stage provides highest performance Rated Current: Ordering Information 45 AYT 6 C 20 to 60A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics Suffix C - Ground Choke Input / Output Style 6 - Threaded 1/4 - 20 bolt AYP6C Models LINE A LOAD A Series designation AYP - Single Stage AYT - Dual Stage B B C C Current Rating 20, 30, 45 or 60A N N LINE GND LOAD GND 98 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance 3-phase RFI Filters for WYE Applications (continued) A Series Electrical Schematics (continued) Case Style AYT6C Models LINE A B B C C N LINE GND LOAD GND N A C E LOAD A D B 2 Available Part Numbers 20AYT6C 30AYT6C 45AYT6C 60AYT6C Terminals: 1/4 x 20 (10) Torque: Three Phase Filters 20AYP6C 30AYP6C 45AYP6C 60AYP6C Mounting studs: No. 8-32 (8) 56 lbf-in 2 6.33 N-m .23 Accessories Mounting bracket kit with captive nuts: AA400: 20A & 30A versions Case Dimensions AA405: 45A & 60A versions Part No. AA406A AA407A 20AYP6C AA405 30AYP6C Protective cover for use with mounting bracket: (For Europe only. Limited availability in other regions) AA406A: 20A & 30A versions 45AYP6C AA400 AA407A: 45A & 60A versions End bell kit (bracket and cover) with captive nuts: 60AYP6C 20AYT6C AA406: 20A & 30A versions 30AYT6C AA407: 45A & 60A versions AA406 / AA407 45AYT6C Kits includes both bracket and cover 60AYT6C Additional captive nuts: A* B C D E AA401: 10 nuts 99 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance 3-phase RFI Filters for WYE Applications (continued) A Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 20AYP6C 30AYP6C 45AYP6C 60AYP6C db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 0.15 1 10 30 Frequency in MHz 0.01 0.1 0.15 1 10 30 Frequency in MHz 10 0.01 0.1 0.15 1 0 10 30 Frequency in MHz 0.01 0.1 0.15 20AYT6C 30AYT6C 45AYT6C 60AYT6C db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 0.15 1 10 30 Frequency in MHz 0.01 0.1 0.15 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 80 10 0.01 0.1 0.15 1 0 10 30 Frequency in MHz 0.01 0.1 0.15 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system AYP6C Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) AYT6C Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 100 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance High Current 3-phase Delta RFI Filters ADT Series UL Recognized ADT Series 2 Specifications * Designed for very high insertion loss for Delta three phase, three wire applications Hipot rating (one minute): Line to Ground: Line to Line: Ordering Information Suffix S - Differential mode coils Omit if none Operating Frequency: 50/60 Hz 63 to 200A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics ADT Series 63ADT6 Available Part Numbers 63ADT6 100ADT6 160ADT6 200ADT6 480 VAC 277 VAC Input / Output Style 6 - Threaded bolt Current Rating 63, 100, 160 or 200A 63ADT6S 100ADT6S 160ADT6S 200ADT6S 2210 VDC 2158 VDC Rated Voltage (max): Phase to Phase: Phase to Ground: Rated Current: 100 ADT 6 S 1.3 A 2.6 A 4.6 A Three Phase Filters * Available with common or differential mode coils Maximum leakage current at 277 VAC 60 Hz, each Line to Ground: ADT6: 63ADT6S: 100, 160, 200ADT6S LINE LOAD A A B B C C 101 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance High Current 3-phase Delta RFI Filters (continued) ADT Series Case Style Electrical Schematics (continued) A 2.00 F 100, 160 & 200 ADT6 1.00 LINE LOAD A A G B B C C G E 1.18 x 0.56 Slot (2x) 0.75 x 0.44 Slot (2x) 0.69 Typ. 2.0 Max. (6x) 3/8-16 Thread (7x) C Mounting Bracket See Note ADT6S H LINE LOAD 0.75 (2x) J 0.75 0.75 A A K (2x) B B C C B C L C L D (2x) C L C L Line Load Case Dimensions Part No. 63ADT6 63ADT6S 100ADT6 100ADT6S 160/200ADT6 160/200ADT6S A B C D E F G H J K 102 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance High Current 3-phase Delta RFI Filters (continued) ADT Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 63ADT6 100ADT6 160ADT6 200ADT6 db db db db 100 100 100 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0.01 0.1 1 10 100 300 Frequency in MHz 0 0.01 0.1 1 10 100 300 Frequency in MHz 100ADT6S 0.01 0.1 1 10 100 300 Frequency in MHz 160ADT6S 0 db db db db 100 100 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 10 10 10 0.01 0.1 1 10 100 300 Frequency in MHz 0 0.01 0.1 1 10 100 300 Frequency in MHz 0 0.1 1 10 100 300 Frequency in MHz 10 100 300 Frequency in MHz 200ADT6S 100 0 0.01 Three Phase Filters 63ADT6S 0 2 20 10 0.01 0.1 1 10 100 300 Frequency in MHz 0 0.01 0.1 1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 103 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Power Line Filters AYA Series UL Recognized* 25AYA6A AYA Series Specifications * For 3-phase, four wire, WYE applications * Cost-effective, universal 3-phase filters * Good attenuation over the complete frequency range of 10kHz to 30MHz * Two different mounting styles available Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 1.62 mA @ 250 VAC 50 Hz: 2.82 mA Hipot rating (one minute): Line to Ground: Line to Line: 1500 VAC 1450 VDC Rated Voltage (max): Phase to Phase: Phase to Ground: 440 VAC 250 VAC Operating Frequency: 50/60 Hz Rated Current: 16 to 100A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 36 AYA 6 A Available Part Numbers Suffix A - Flange Mounted (for threaded bolt style only) Omit for bulkhead mount or for Terminal Blocks (flange mount only) Input / Output Style 6 - Threaded bolt 10 - Terminal block (flange mount only) Flange Mount 16AYA6A 16AYA10 25AYA6A 36AYA6A 36AYA10 50AYA6A 63AYA6A 63AYA10 100AYA6A Bulkhead Mount 16AYA6 25AYA6 36AYA6 50AYA6 AYA Series Current Rating 16, 25, 36, 50, 63 or 100A *UL Approvals for all models except: 16AYA10, 36AYA10, 63AYA10, 63AYA6, 63AYA6A and 100AYA6A 104 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Power Line Filters (continued) AYA Series Electrical Schematic A AYA6 (Bulkhead mount with screw terminals) LINE LOAD A B B C C N N GND A D 2 2.95 0.01 75.0 0.3 B GND Three Phase Filters 1.73 0.01 44.0 0.3 C Case Style AYA6A (Flange mount with screw terminals) 16AYA10 C A D 4.92 0.02 125.0 0.5 E B E B 2.76 0.012 70.0 0.3 C 2.76 0.012 70.0 0.3 D A 105 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Power Line Filters (continued) AYA Series 36AYA10 C Case Dimensions Part No. 16AYA6 /A 25AYA6 /A 36AYA6 /A 50AYA6 /A E B 63AYA6 /A 100AYA6A 2.76 0.012 70.0 0.3 16AYA10 D A 36AYA10 63AYA10 A B C D E* 63AYA10 C E B 4.53 0.012 115.0 0.3 D A 106 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Power Line Filters (continued) AYA Series Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system 16AYA 25AYA 36AYA 50AYA db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 100AYA db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Three Phase Filters 63AYA 1 2 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 107 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Power Line Filters for High Noise Applications AYC Series UL Recognized* 150AYC10B AYC Series Specifications * For 3-phase, four wire, WYE applications Maximum leakage current each Line to Ground: 120 VAC 60Hz * Very high attenuation * Low leakage current * Ideal for EMC troubleshooting and refurbishing in the field * Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications Ordering Information 150 AYC 10 B -95 Terminal Block Option -95 - 95mm terminal block available on 150A only Omit for standard terminals Filter Type B - Single stage Input / Output Style 10 - Terminal block 16A 25 & 36A 63A 80, 100 & 150A 180, 200A 62 mA 68 mA 74 mA 74 mA 111 mA Hipot rating (one minute): Line to Ground: Line to Line: Line to Neutral: 277 VAC 50Hz 106 118 128 129 192 mA mA mA mA mA 1850 VDC 1850 VDC 1450 VDC Rated Voltage (max): Phase to Phase: Phase to Ground: 480 VAC 277 VAC Operating Frequency: 50/60 Hz Rated Current: 16 to 200A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic AYC Series Current Rating 16, 25, 36, 63, 80, 110, 150, 180 or 200A Available Part Numbers 16AYC10B 25AYC10B 36AYC10B 63AYC10B 80AYC10B 110AYC10B 150AYC10B 150AYC10B-95 180AYC10B 200AYC10B A LINE LOAD A B B C C N N GND GND *All except 200AYC10B 108 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Filters for High Noise Applications (continued) AYC Series Case Styles 16, 25, 36, 63AYC10B Case Dimensions Part No. E A 80, 110, 150AYC10B / -95 B D C D E Terminal Ground 16AYC10B Line / Load C Ground 25AYC10B Line / Load Ground 180, 200AYC10B 36AYC10B Line / Load Ground B D 63AYC10B Line / Load 80, 110, 150AYC10B E E A C 2 Terminals Part No. E A Three Phase Filters C B 25AYC10B 36AYC10B 63AYC10B 80, 110 & 150AYC10B 150AYC10B-95 180AYC10B 200AYC10B 16AYC10B B D A Ground Line / Load 150AYC10B-95 Ground 180AYC10B Line / Load 200AYC10B Size Torque max. lbf-in [N-m] M5 26.58 [3.0] 4mm 7.08 [0.8] terminal block M5 26.58 [3.0] 6mm 15.93 [1.8] terminal block M5 26.58 [3.0] 10mm 15.93 [1.8] terminal block M6 53.1 [6.0] 16mm 20.35 [2.3] terminal block M10 177.0 [20.0] 50mm 70.80 [8.0] terminal block M10 177.0 [20.0] 95mm 177.0 [20.0] terminal block 109 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase WYE RFI Filters for High Noise Applications (continued) AYC Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 16AYC10B 25AYC10B 36AYC10B 63AYC10B db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 80AYC10B 110AYC10B 150AYC10B 180, 200AYC10B db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 110 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact Low Current 3-phase WYE RFI Filters AYO Series UL Recognized CSA Certified VDE Approved AYO Series 2 Specifications * For 3-phase, four wire, WYE applications * Good for attenuation beginning at 100kHz * Space saving design Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: @ 250 VAC 50 Hz: Hipot rating (one minute): Line to Ground: Line to Line: * Low leakage current * Easy to connect terminals Ordering Information Input / Output Style 1 - 0.25 [6.3] spade terminals AYO Series 20A 2.0 mA 3.0 mA 3.5 mA 5.5 mA 1500 VAC 1450 VDC Rated Voltage (max): Phase to Phase: Phase to Neutral / Ground: 440 VAC 250 VAC Operating Frequency: 50/60 Hz Rated Current: 10 AYO 1 3, 6, 10A Three Phase Filters * Filters each of the three lines plus neutral 3 to 20A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic Current Rating 3, 6, 10 or 20A LINE LOAD Available Part Numbers 3AYO1 10AYO1 6AYO1 20AYO1 N N 111 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact Low Current 3-phase WYE RFI Filters (continued) AYO Series Case Style Case Dimensions A D Part No. AYO Series B A B C D E C E Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 3AYO1 6AYO1 10AY01 20AYO1 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 112 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 3-phase Delta RFI Filters for Universal Applications BCF Series UL Recognized VDE Approved BCF Series 2 Specifications * Designed for universal applications * Low weight * Insulated, high quality safety terminals for input and output * Cost-effective design * Good common and differential mode performance below 100kHz * Applications include; 3-phase inverters, converters, variable speed motor drives and process automation equipment * Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications Ordering Information Maximum leakage current each Line to Ground*: @ 277 VAC 50 Hz: 30 mA *If 2 phases are interrupted, this leakage current may rise to a significantly higher level Hipot rating (one minute): Line to Ground: Line to Line: Three Phase Filters * Compact book-form design 1850 VAC 1850 VDC Rated Voltage (max): Phase to Phase: Phase to Ground: 480 VAC 277 VAC Operating Frequency: 50/60 Hz Rated Current: 7 to 180A Operating Ambient Temperature Range (at rated current Ir): -10C to +50C In an ambient temperature (Ta) higher than +50C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/35 55 BCF 10 Input / Output Style 10 - Terminal block Electrical Schematic LINE BCF Series LOAD Current Rating 7, 16, 30, 42, 55, 75, 100, 130 or 180A Available Part Numbers 7BCF10 30BCF10 55BCF10 100BCF10 180BCF10 16BCF10 42BCF10 75BCF10 130BCF10 113 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 3-phase Delta Filters for Universal Applications (continued) BCF Series Case Style Terminals H F Part No. 7BCF10, 16BCF10 30BCF10 42BCF10 55BCF10 75BCF10 100BCF10, 130BCF10 180BCF10 G D A C Ground Terminals Line/Load Terminals M5 4mm M5 10mm M6 10mm M6 16mm M6 25mm M10 50mm M10 95mm E B L1 L2 L3 L1 L2 L3 Case Dimensions Part No. 7BCF10 16BCF10 30BCF10 42BCF10 55BCF10 75BCF10 100BCF10 130BCF10 180BCF10 A B C D E F G H 114 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 3-phase Delta Filters for Universal Applications (continued) BCF Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 7BCF10 16BCF10 30BCF10 42BCF10 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 2 0.01 0.1 75BCF10 100BCF10 130BCF10 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz Three Phase Filters 55BCF10 1 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 180BCF10 db 100 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 90 80 70 60 50 40 30 20 10 0 0.01 0.1 Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 115 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase Delta Power Line Filter for High Voltage Applications CFN Series UL Recognized* CFN Series Specifications * Universal high current filter * Suitable for industrial applications including; motor drives, inverters, converters, uninterruptible power supplies and mining equipment Maximum leakage current at 10% unsymmetrical mains Line to Ground (3 Phase WYE Center tapped)*: @ 120 VAC 60 Hz: 5.0 mA @ 277 VAC 50 Hz: 9.6 mA *If 2 phases are interrupted, this leakage current may rise to a significantly higher level Hipot rating (one minute): Line to Ground: Line to Line: Ordering Information 400 CFN 12 Rated Voltage (max): Phase to Phase: Phase to Ground: 480 VAC 277 VAC Operating Frequency: 50/60 Hz Rated Current: Input / Output Style 12 - Copper bus bar CFN Series 2210 VDC 2158 VDC 300 to 600A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Current Rating 300, 400, 500, 600A Electrical Schematic L1 L1 L2 L2 L3 L3 PE PE Available Part Numbers 300CFN12 500CFN12 400CFN12 600CFN12 *400CFN12 only 116 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase Delta Power Filter for High Voltage Applications (continued) CFN Series Case Style A D1 8.27 8.27 PE L1 E CL L1 L I N E L2 L O A D L3 3.94 L2 F G 4.72 2 B L3 PE Three Phase Filters 5.0 CL M5 Insert (4 places) C 2.52 D2 Case Dimensions Part No. 300-600CFN12 A B C D1 D2 E F G H Performance Data Typical Insertion Loss Minimum Insertion Loss Measured in closed 50 Ohm system Measured in closed 50 Ohm system 300-600CFN12 db 100 90 80 70 60 50 Common Mode / Asymmetrical (Line to Ground) 40 30 20 Differential Mode / Symmetrical (Line to Line) 10 0 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 117 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 3-phase Delta External Power Line Filter for Frequency Converters FCD Series UL Recognized 6FCD10 FCD Series Specifications * Suitable to meet the latest EMC standards * Insulated safety terminals * Suitable for EMC troubleshooting in the field * Very high attenuation * High insertion loss * BS models optimized for very high insertion loss * BS models suitable for infeed/regenerative (ER) applications * Touch safe terminals provide easy connections and prevent inadvertent contact for safety in the most demanding applications Ordering Information 150 FCD 10 BS -95 Terminal Block Option -95 - 95mm terminal block available on 150A only omit for standard terminals Filter Type B - Single stage BS - High performance Single stage. Omit for dual stage Input / Output Style 10 - Terminal Block Maximum leakage current voltage drop to virtual N to PE/V: 6FCD10: 12 & 16FCD10: 25, 36 & 50FCD10: 12 & 16FCD10B: 25& 36FCD10B: 50FCD10B: 80 & 110FCD10B: 150FCD10B: 180 & 230FCD10B: FCD10BS: .26 mA/V .45 mA/V .52 mA/V .46 mA/V .52 mA/V .57 mA/V .62 mA/V .63 mA/V .92 mA/V 3.25 mA/V Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max): Phase to Phase: Phase to Neutral / Ground: 480 VAC 277 VAC Operating Frequency: 50/60 Hz Rated Current: 6 to 230A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematics 6FCD10 Power line Device FCD Series Current Rating 6, 12, 16, 25, 36, 50, 80, 110, 150, 180 or 230A PE PE 118 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 3-phase Delta External Filter for Frequency Converters (continued) FCD Series Electrical Schematics (continued) Available Part Numbers 12 to 50A FCD10 Power line Device L1 L1 L2 L2 L3 L3 PE PE Device L1 L1 L2 L2 L3 L3 Slots: .260 6.61 D PE 80 to 230A FCD10B Power line 2 Case Styles 6 to 50A FCD10 & FCD10B B PE 12FCD10B 50FCD10BS 16FCD10B 80FCD10BS 25FCD10B 110FCD10BS 36FCD10B 150FCD10BS 50FCD10B 150FCD10BS-95 80FCD10B 180FCD10BS 110FCD10B 230FCD10BS 150FCD10B 150FCD10B-95 180FCD10B 230FCD10B Three Phase Filters 12 to 50A FCD10B Power line 6FCD10 12FCD10 16FCD10 25FCD10 36FCD10 50FCD10 F E Device L1 L1 L2 L2 L3 L3 C A 80 to 150A FCD10B 50 to 150A FCD10BS PE Slots: .260 6.61 PE FCD10BS Power line B Device L1 L1 L2 L2 L3 L3 D F E 150FCD10B-95 Terminal Block C PE PE A A (150FCD10B-95) 119 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 3-phase Delta External Filter for Frequency Converters (continued) FCD Series Case Styles (continued) 180 to 230FCD10B\BS Slots: .260 6.61 Case Dimensions Part No. Center slot on 180 & 230A only D E F 25FCD10/10B 36FCD10/10B 50FCD10/10B F E C Terminals Terminal Size Torque max. lbf-in [N-m] Ground 8-32 20.7 [2.34] 4mm 7.08 [0.8] 6FCD10 Line/Load terminal block Ground M5 26.58 [3.0] Line/Load 4mm 7.08 [0.8] terminal block M5 26.58 [3.0] Line/Load 6mm 15.93 [1.8] Ground Line/Load Ground 50FCD10BS Line/Load Ground 80 to 150FCD10B 80 to 150FCD10BS Line/Load 150FCD10B/BS-95 Ground 180FCD10B/BS Line/Load 230FCD10B/BS 80FCD10B/BS 110FCD10B/BS 150FCD10B/BS terminal block M5 10mm terminal block M10 16mm terminal block M10 180FCD10B/BS 230FCD10B/BS Performance Data Typical Insertion Loss Ground 50FCD10/10B 50FCD10BS 150FCD10B-95 150FCD10BS-95 A 25FCD10/10B 36FCD10/10B C 12FCD10/10B 16FCD10/10B B D 12FCD10/10B 16FCD10/10B B 6FCD10 Part No. A 26.58 [3.0] 15.93 [1.8] 88.5 [10.0] 20.36 [2.3] 88.5 [10.0] Measured in closed 50 Ohm system 6FCD10 12FCD10 db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 50mm terminal block 70.80 [8.0] M10 88.5 [10.0] 95mm 177.0 [20.0] terminal block 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 120 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 3-phase Delta External Filter for Frequency Converters (continued) FCD Series Performance Data (continued) Typical Insertion Loss (continued) Measured in closed 50 Ohm system 16FCD10 25FCD10 36FCD10 50FCD10 db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 2 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 16FCD10B 25FCD10B 36FCD10B db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.01 0.1 1 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 80FCD10B 110FCD10B 150FCD10B db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 230FCD10B 50/80/110FCD10BS 150FCD10BS db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 180FCD10BS 230FCD10BS db 100 db 100 90 90 80 10 30 Frequency in MHz 0 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 30 Frequency in MHz 10 0.01 180FCD10B 0 1 10 0.01 50FCD10B 0 10 30 Frequency in MHz Three Phase Filters 12FCD10B 1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 121 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 3-phase Delta External Filter for Frequency Converters (continued) FCD Series Performance Data (continued) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 122 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 2 Three Phase Filters 123 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 124 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 3. Power Inlet Filters & Power Entry Modules -- Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .126 Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .128 Power Entry Module Selector Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .129 C Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .130 CU Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .134 EBF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .138 EC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .141 ED Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .144 EEA & EEB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EAS & EBS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EAH & EBH Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .148 EEJ Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJH & EJHS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJM & EJMS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EJS Models . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .153 EF Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .160 EJT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .163 GG & HG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .166 H Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .169 J Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .172 L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .175 LA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .180 M Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .183 P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .192 SR Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .201 SRB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .203 3 Power Inlet Filters & Power Entry Modules 125 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Introduction Power Inlet Filters feature power sockets integrated with EMI filters enclosed in RFI jackets. The AC power socket complies with IEC an standard to assure worldwide power cord compatibility. These filters are available in a wide variety of filtering, shielding, mounting and termination styles that provide the most compact and cost-effective inlet filtering available. For DC power inlet filters, see the DC section. Corcom EJS Series IEC Inlet RFI Filter Power Entry Modules incorporate power sockets with filtering, fuses, switching and voltage selection in a variety of configurations to reduce cost, space and labor. The power sockets comply with IEC standards to assure worldwide AC power cord compatibility. For DC power entry modules, see the DC section. Equipment marketed worldwide, must operate with * Multiple different wall plugs and sockets Corcom P Series CHAMELEON Power Entry Module * Different fuse standards in America and Europe * Different voltages in different regions * On/Off switching options * Different EMI requirements in different regions The combinations are endless. Your equipment needs a single solution. TE Connectivity's power entry modules can provide ONE mechanical solution for a variety of power entry needs. Each series supports several different configurations to suit the market requirements. Each starts with an international standard power cord connector, and includes options for fusing, voltage selection, switching, and filtering. Selecting one power entry module series simplifies the mechanical design, and each version within the series replaces the cost and labor of up to including up to five individual parts in the equipment bill of materials. With hundreds of different combinations of power entry functions, the modules in this catalog offer a cost-effective solution to the power entry needs of many systems. It is easy to select the module that best serves your needs. 126 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Introduction (continued) The selector guides on the next two pages help you configure the best power entry module for your application. Just select options from this menu of five categories. IEC60320-1 Socket - Common to all modules, the 60320-1 universal socket allows your equipment to be used in every country. Simply select a power cord with a mating IEC 60320-1 plug on one end, and a regionally appropriate plug on the other. Fusing Options - North American (1/4" x 11/4" 3AG) or Metric (5mm x 20mm) or both? One fuse or two? Voltage Selection Options - 4-voltage, 2-voltage, or 1-voltage? Multitap? Center-tap? Dual primary? Power Switch - Yes or no? Double pole (DPST) or single (SPST)? These power entry module switches feature international on - off markings, current ratings up to 15A and high inrush current. Shielding - reduce radiated emissions through the panel cut-out by selecting a module with a shield (optional on the C, CU, M and P). 3 Filtering options - Choice of six filter circuits (all with low leakage current to meet international standards) to fit specific filtering objectives: Power Inlet Filters & Power Entry Modules * General purpose (C, CU, GG, J, LA, M and P) - most cost-effective, for susceptibility and for high-frequency "clean-up" when used with a boardlevel filter * Medical (in C, GG, L, M, and P series) - for medical equipment * Emissions/Linear (in L and P series) - capable of bringing most digital equipment with linear power supplies into FCC compliance * Emissions/SMPS-FCC (in P, LA and M series) - capable of bringing most digital equipment with switch-mode power supplies into FCC Class B compliance * Emissions/SMPS-VDE (in P, LA and M series) - capable of bringing most digital equipment with switch-mode power supplies into VDE level B (as well as FCC Class B) compliance Want more filtering options? Select a general purpose or an unfiltered module (C, CU, J, L, M, P, or SR series) and wire it up connect it to the load through one of the many Corcom chassis-mounted filter of your choice from the choices found in this comprehensive catalog. TE's Corcom product engineers can also design a custom filter for your specific applicaiton. Available accessories expand your options even further. A Corcom product sales engineer can assist you with selecting the right filter for your application. Having arrived at the best possible combination of power entry elements, TE's worldwide agency approvals will help ease your product through the necessary safety agencies. File numbers and Safety Agency information is listed in Section 7. 127 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Selector Chart Integrated IEC60320-1 Power Socket Additional Features Required? No Power inlet only with or without filtering YES Requires switch, fuseholder and/or voltage selection Power Entry Module Integrated Functions For Medical Application Yes No Switching EJH SRB Series 1-20A Page 153 Series 15A Page 203 EJM EF Series 1-15A Page 153 Series 1-15A Page 160 NEW SR Series 15A Page 201 Series 1-15A Page 130 U nfi l te re d H Series 1-15A Page 169 CU Series* 1-15A Page 134 L M Series 3-6A Page 183 Series 1-20A Page 153 P Series 3-10A Page 192 EBF ED GG Series** 1-10A Page 166 Series 2-6A Page 175 EEJ / EJS Series 1-10A Page 138 Voltage Select C Try The New Styles Try The Fuseholder Available with or without filtering** for medical* and/or non-medical applications. Series 1-15A Page 144 EC Series 1-10A Page 141 *CU Series not available for Medical versions **GG Series not available without filtering EJT Series 1-20A Page 163 128 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module Selector Guide Unfiltered Filtered Options Series Product Photo C Max. Current Rating 15A Product Photo Max. Current Rating Filter Type 10A Medical & General Purpose Yes DPST N/A N/A 15A General Purpose Yes SPST N/A N/A 10A Medical & General Purpose N/A N/A Metric 6A Medical & General Purpose Optional DPST Single or 4 North American or Metric Medical, General Purpose & Optional Switch Mode DPST Power Supply Single, 2 or 4 North American or Metric On/Off Voltage Fuse Switch Selections Holder NEW CU 15A 3 NEW L M P 6A 6A 10A 6A 10A Medical, General Purpose & Optional Switch Mode DPST Power Supply Single or 2 Power Inlet Filters & Power Entry Modules GG Filtered Only North American or Metric New High Performance versions in PE and PM Mounting Styles N/A = Not Available 129 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Switch C Series UL Recognized CSA Certified VDE Approved* 15CS1 3CFS1 C Series Specifications * Two function power entry module combining a DPST switch and an IEC 60320-1 inlet Maximum leakage current each Line to Ground: F Models @ 120 VAC 60 Hz: @250 VAC 50 Hz: * Snap-in or flange mounting * Available with or without a shielded general purpose or medical grade filter Hipot rating (one minute): Line to Ground: Line to Line: * Two element circuit provides enhanced EMI attenuation Rated Voltage: * Reduce OEM wiring time with optional pre-connected line and switch terminals Rated Current: Output Styles 1 - Spade terminals 250 VAC 50/60 Hz 1 to 15A* DPST 10,000 operations at 51A max. inrush Ordering Information 10 C F S 1 2 A 5 A 2250 VDC 1450 VDC Operating Frequency: Switch: H & Unfiltered .25 mA .40 mA .250 Terminal Push-on Force: 18 lb. / 80N (max.) .188 Terminal Push-on Force: 15 lb. / 67N (max.) (size varies) Mounting Styles E - Flange Mount S - Snap-in Filter Type or Terminal Option F - General purpose H - Medical B - No filter, includes Pre-connected terminals Omit if none C Series Current Rating 1, 3, 6, 10 or 15A (Filtered versions up to 10A) Available Part Numbers Filtered Versions 1CHE1 1CFE1 3CHE1 3CFE1 6CHE1 6CFE1 10CHE1 10CFE1 1CHS1 1CFS1 3CHS1 3CFS1 6CHS1 6CFS1 10CHS1 10CFS1 Non-filtered Versions Standard Terminals Pre-connected Terminals 10CS1 10CE1 15CS1 15CE1 10CBS1 10CBE1 15CBS1 15CBE1 *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC 130 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Switch (continued) C Series Electrical Schematics CE, CBE A F Models .210 5.34 B LINE LOAD F Max. C H Models LINE LOAD 3 CFS, CHS Power Inlet Filters & Power Entry Modules B Models C Power On/Off L L Note 1 Note 2 Note 1 Note 2 G G N N Note 1: Jumpers provided on CBS and CBE versions only. Note 2: Location of optional filter A .210 5.34 Max. B Case Styles CFE, CHE CS, CBS B .210 Max. 5.34 A C C F .210 5.34 Max. B A 131 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Switch (continued) C Series Case Styles (continued) Case Dimensions CBS, CBE Pre-Connected Terminals Part No. CS, CBS CE, CBE CFS, CHS CBS, CBE Side View CBS Rear View CBE Rear View CFE, CHE A B C D E F Recommended Panel Cutout Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord D .06 R max 1.52 E F 132 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Switch (continued) C Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1CF 3CF 6CF 10CF db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 1CH 3CH 6CH 10CH db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 3 Power Inlet Filters & Power Entry Modules 50 40 10 30 Frequency in MHz 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 133 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 1U Height Switched Power Entry Module CU Series UL Recognized CSA Certified VDE Approved* 6CUFS1 15CUE1 CU Series Specifications * Designed for popular 1U (1 3/4") height rack mounted equipment Maximum leakage current each Line to Ground: * Two function power entry module combining a SPST switch and an IEC 60320-1 inlet Filtered @ 120 VAC 60 Hz: @250 VAC 50 Hz: Unfiltered 2 A 5 A .25 mA .40 mA * Snap-in, flange and flush mounting Hipot rating (one minute): Line to Ground: Line to Line: * Reduce OEM wiring time with optional pre-connected line and switch terminals Operating Voltage: Ordering Information 15 CU 10 B S 1 Rated Current: 2250 VDC 1450 VDC 120/250 VAC Operating Frequency: 50/60 Hz 1 to 15A* Switch: 50A inrush capable SPST Terminal Push-on Force: 15 lb. / 67N (max.) Output Styles 1 - .187 [4.8] spade terminals Mounting Styles E - Flange Mount (Horizontal) F - Flush Mount (Filtered only) S - Snap-in Filter Type or Terminal Option F - General purpose B - No filter, includes pre-connected terminals Omit if none Side Snap-in Option Non-filtered versions only 10 - Side snaps 1.0mm max. panel 15 - Side snaps 1.5mm max. panel Omit for none or standard configuration Available Part Numbers 1CUFE1 3CUFE1 6CUFE1 10CUFE1 15CUFE1 Filtered Versions 1CUFF1 3CUFF1 6CUFF1 10CUFF1 15CUFF1 Non-filtered Versions 1CUFS1 3CUFS1 6CUFS1 10CUFS1 15CUFS1 Standard Terminals Pre-connected Terminals 15CUE1 15CUS1 15CU10S1 15CU15S1 15CUBE1 15CUBS1 15CU10BS1 15CU15BS1 CU Series Current Rating 1, 3, 6, 10 or 15A *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC 134 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 1U Height Switched Power Entry Module (continued) CU Series Electrical Schematic LINE CUFS1 LOAD C Case Styles A CUFE1 B C 3 CUE1 B F Power Inlet Filters & Power Entry Modules C A CUFF1 B F A C CUS1 F B A C A B 135 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 1U Height Switched Power Entry Module (continued) CU Series Case Styles (continued) Case Dimensions Part No. CU10S1 & CU15S1 CUFE1 C CUFF1 CUFS1 A B CUBE1 Pre-Connected Terminals CUE1, CUBE1 CUS1, CUBS1 10CUS1, 10CUBS1 15CUS1, 15CUBS1 A B C D E F Recommended Panel Cutout F R. Max CUBS1 Pre-Connected Terminals E CU10BS1 & CU15BS1 Pre-Connected Terminals D Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord 136 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact 1U Height Switched Power Entry Module (continued) CU Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1CUF 3CUF 6CUF 10CUF db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 3 15CUF db 100 90 80 Power Inlet Filters & Power Entry Modules Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 70 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 137 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Accessory Outlet Filter EBF Series UL Recognized CSA Certified VDE Approved EBF1 EBF4 EBF Series Specifications * Accessory IEC 60320-1 C13 filtered outlet * Allows connection of accessories while filtering noise between a system and the accessory * Enhanced performance across the frequency range * Grounded connection * Suitable for international usage Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .25 mA @250 VAC 50 Hz: .50 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Ordering Information 3 EBF 1 Output Styles 1 - .250 [6.3] spade terminals 4 - Wire leads (bottom) 1 to 10A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic EBF Series ACCESSORY OUTLET LINE Current Rating 1, 3, 6, or 10A Available Part Numbers 1EBF1 3EBF1 6EBF1 10EBF1 1EBF4 3EBF4 6EBF4 10EBF4 138 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Accessory Outlet Filter (continued) EBF Series Case Styles Case Dimensions EBF1 Part No. C EBF1 D E A B EBF4 A B C D E EBF4 3 Recommended Panel Cutout E D A B Power Inlet Filters & Power Entry Modules 1.01 25.7 C .14 Dia. 3.6 1.40 35.6 1.575 .004 40.0 0.1 .20 R Typ. 5.1 139 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Accessory Outlet Filter (continued) EBF Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1EBF 3EBF 6EBF 10EBF db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 140 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance EMI Power Inlet Filter EC Series EC8 UL Recognized CSA Certified VDE Approved EC2 EC4 EC1 EC Series Specifications * Three element differential mode circuit provides the highest attenuation of any available standard inlet filter Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .25 mA @250 VAC 50 Hz: .50 mA * High common mode inductance Hipot rating (one minute): Line to Ground: Line to Line: * High differential mode capacitance * Effective attenuation of Line to Ground and Line to Line noise across the frequency range * Includes several termination options Ordering Information Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: Power Inlet Filters & Power Entry Modules * Performance and application similar to the ED series but with higher differential mode performance 3 2250 VDC 1450 VDC 1 to 10A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 3 EC 1 Output Styles 1 - .250 [6.3] spade terminals (back) 2 - .250 [6.3] spade terminals Electrical Schematic LINE LOAD (bottom) 4 - Wire leads (bottom) 8 - Wire leads (back) EC Series Current Rating 1, 3, 6, or 10A Available Part Numbers 1EC1 3EC1 6EC1 10EC1 1EC2 3EC2 6EC2 1EC4 3EC4 6EC4 1EC8 3EC8 6EC8 141 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance EMI Power Inlet Filter (continued) EC Series Case Styles EC1 Case Dimensions Part No. C A D E EC1 B EC2 EC2 EC4 EC8 C A B C D E F .65 Max. 16.5 D E A B Recommended Panel Cutouts Front Mount Back Mount .820 20.8 EC4 .140 3.56 1.200 30.48 1.575 40.01 E A .140 3.56 1.200 30.48 1.575 40.01 .062 R. 1.58 Typ. .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted Blue Brown D Green/Yellow C .900 22.9 B F Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord F EC8 F Blue Green/Yellow D E B FA601: Insulating Shroud Brown .413 Dia. 10.5 .271 Dia. 6.9 F A .118 3.0 1.39 35.4 C 1.17 29.7 .767 19.5 142 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance EMI Power Inlet Filter (continued) EC Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1EC 3EC 6EC 10EC db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 3 10 30 Frequency in MHz Power Inlet Filters & Power Entry Modules Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 143 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Medium Performance Compact EMI Power Inlet Filter ED Series ED2 UL Recognized CSA Certified VDE Approved* ED1 / ED1C EC4 / ED4C EC8 / ED8C ED Series Specifications * Two element circuit provides medium attenuation * Available with an internal ground-circuit inductor (C versions) to isolate equipment chassis from power line ground at radio frequencies * Versions up to 15A* * Similar to EEJ Series with alternative termination options * See the EC Series for better differential mode performance Ordering Information 3 ED 1 C Ground Circuit Inductor Omit if none Output Styles 1 - .250 [6.3] spade terminals (back) 2 - .250 [6.3] spade terminals (bottom) 4 - Wire leads (bottom) 8 - Wire leads (back) Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .22 mA @250 VAC 50 Hz: .38 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 1 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Available Part Numbers 1ED1 3ED1 6ED1 10ED1 15ED1 1ED2 3ED2 6ED2 1ED4 3ED4 6ED4 1ED8 3ED8 6ED8 15ED8 Ground Circuit Inductor Versions 6ED1C 10ED1C 6ED4C 6ED8C ED Series Current Rating 1, 3, 6, 10 or 15A Electrical Schematic LINE LOAD 1 *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC Note 1: C versions only Note 1: C Versions only 144 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Medium Performance Compact EMI Power Inlet Filter (continued) ED Series Case Styles ED1 & ED1C ED8 & ED8C F Blue C Green/Yellow D E B Brown A D E B F A C ED2 3 Power Inlet Filters & Power Entry Modules Case Dimensions C Part No. .65 Max. 16.5 D E A B ED4 & ED4C 1ED1, 3ED1, 6ED1 1ED2, 3ED2, 6ED2 1ED4, 3ED4, 6ED4 1ED8, 3ED8, 6ED8 6ED1C C E A Blue Brown D Green/Yellow 6ED4C 6ED8C B 10ED1 /1C, 15ED1 F 15ED8 F A B C D E F 145 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Medium Performance Compact EMI Power Inlet Filter (continued) ED Series Recommended Panel Cutouts Front Mount Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Back Mount .820 20.8 .900 22.9 .140 3.56 1.200 30.48 1.575 40.01 .140 3.56 1.200 30.48 1.575 40.01 .062 R. 1.58 Typ. .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted FA601: Insulating Shroud .413 Dia. 10.5 .271 Dia. 6.9 .118 3.0 1.39 35.4 1.17 29.7 .767 19.5 Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1ED 3ED 6ED 6ED1C db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 100 Frequency in MHz 10ED1 & 10ED1C 0 1 10 100 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 15ED db 100 db 100 90 80 90 80 70 70 60 60 50 50 40 40 30 30 20 20 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 10 0 0.1 0 0.1 1 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz 146 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Medium Performance Compact EMI Power Inlet Filter (continued) ED Series Performance Data (continued) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 3 Power Inlet Filters & Power Entry Modules 147 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective EMI Power Inlet Filter EEA & EEB Series Including the EAS/EBS and EAH/EBH Models UL Recognized CSA Certified VDE Approved EEA1 / EEB1 EEA2 / EEB2 EEAP / EEBP EEA Series * Compact single stage EMI filter with IEC 60320-1 C14 inlet * Two element circuit provides basic attenuation * Same performance as the EF Series * Available in three terminal configurations * Supersedes EF Series Specifications Maximum leakage current each Line to Ground: EEA/EEB EAS/EBS EAH/EBH @ 120 VAC 60 Hz: .22 mA 2 A @ 250 VAC 50 Hz: .38 mA 5 A Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max.): 250 VAC * Compact EMI filter with IEC 60320-1 C14 inlet Operating Frequency: 50/60 Hz * Two element circuit provides extended attenuation Rated Current: EEB Series * Extended differential mode performance * Available in three terminal configurations 1 to 10A Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 EAS & EBS Models * Same performance as EEA and EEB Series * Snap-in mounting * Spade terminals Electrical Schematic LINE EAH & EBH Models 1 * Same size as EEA and EEB * Minimal leakage current suitable for medical applications * Flange mounted LOAD 1 Note 1: Not present in EAH / EBH Versions Note 1: Not present in EAH / EBH versions * Spade terminals 148 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective EMI Power Inlet Filter (continued) EEA & EEB Series Ordering Information Available Part Numbers 3 EEB 1 Output Styles 1 - .250 [6.3] spade terminals (back) 2 - .250 [6.3] spade terminals (bottom) P - PC board pins Series EEA - Basic Inlet Filter EAS - Snap-in EEA Filter EAH - Medical EEA Filter EEB - Extended EMI Performance EBS - Snap-in EEB Filter EBH - Medical EEB Filter Accessories EEB Models 1EEA1 1EEA2 1EEAP 3EEA1 3EEA2 3EEAP 6EEA1 6EEA2 6EEAP 10EEA1 10EEA2 10EEAP 1EEB1 1EEB2 1EEBP 3EEB1 3EEB2 3EEBP 6EEB1 6EEB2 6EEBP 10EEB1 10EEB2 10EEBP EAS Models EBS Models 1EAS1 3EAS1 6EAS1 10EAS1 1EBS1 3EBS1 6EBS1 10EBS1 EAH Models EBH Models 1EAH1 3EAH1 6EAH1 10EAH1 1EBH1 3EBH1 6EBH1 10EBH1 3 Power Inlet Filters & Power Entry Modules Current Rating 1, 3, 6, or 10A EEA Models GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord FA601: Insulating Shroud .413 Dia. 10.5 .271 Dia. 6.9 .118 3.0 EAS / EBS 1.39 35.4 1.17 29.7 .767 19.5 149 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective EMI Power Inlet Filter (continued) EEA & EEB Series Case Styles Case Dimensions EEA1, EEB1, EAH1 & EBH1 EEA1, EEB1, EAH1, EBH1 C EEA2, EEB2 D E A B A B C Part No. EEAP, EEBP EAS1, EBS1 D E Recommended Panel Cutouts EEA2 & EEB2 EEA, EEB, EAH, EBH Front Mount C Back Mount .820 20.8 .50 Max. 12.7 A D E B .900 22.9 .140 3.56 1.14* 28.96* 1.575 40.01 1.200 30.48 1.575 40.01 .12 R. 3.05 Typ. * 0.02 [0.51] .140 3.56 .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted EEAP & EEBP EAS, EBS C G .537 Ref. 13.68 .380 Max. 9.652 0.551 .010 D .815 20.70 13.995 A E B R 0.188 [4.78] (4X) PC Board Layout EAS1 & EBS1 0.075 1.91 Max. C D E A .81 20.5 0.520 13.21 B .685* 17.40* 0.551 13.99 *.015 [0.38] 150 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective EMI Power Inlet Filter (continued) EEA & EEB Series Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system EEA, EAS Models 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 3 EEB, EBS Models 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0 Power Inlet Filters & Power Entry Modules 1A 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz EAH Models 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 EBH Models 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10 0.1 1 10 30 Frequency in MHz 0 0.1 151 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective EMI Power Inlet Filter (continued) EEA & EEB Series Performance Data (continued) Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 152 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models UL Recognized CSA Certified VDE Approved* 20EJH1 3EEJ1 20EEJ8 EEJ Series * Compact EMI filter with IEC 60320-1 C14 Inlet * Enhanced two element circuit provides medium attenuation to 30MHz * Compact and cost-effective design * Supersedes most ED Series versions * Includes 20A version with standard IEC 60320-1 C20 inlet * Flanged mounting EJS Models * Same performance as the EEJ Series * Snap-in mounting * Several termination styles Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 2250 VDC 1450 VDC Power Inlet Filters & Power Entry Modules * Several termination styles Specifications Maximum leakage current each Line to Ground: EEJ/EJS EJH EJM @ 120 VAC 60 Hz: .22 mA 2 A .01 mA @250 VAC 50 Hz: .38 mA 5 A .017 mA 1 to 20A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 * Includes 20A version with standard IEC 60320-1 C20 inlet EJH & EJHS Models * Minimal leakage current suitable for patientcontact medical applications * Flanged mounting the same as the EEJ Series Electrical Schematic LINE * Also available in snap-in versions (EJHS) LOAD 1 * Two element circuit provides modest EMI attenuation above 1MHz 1 * Capacitive input (refer to the H Series for capacitive output) * EJHS models feature snap-in mounting Note 1: Not present in EJH versions EJM & EJMS Models * Low leakage current, suitable for most medical applications * Improved EMI attenuation up to 200MHz * Mechanically the same as the EEJ Series with flange or snap-in mounting *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC 20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC * EJMS models feature snap-in mounting 153 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series (continued) Including the EJH/EJHS, EJM/EJMS and EJS Models Ordering Information Available Part Numbers 3 EEJ 1 Output Styles 1 - .250 [6.3] spade terminals (back) 2 - .250 [6.3] spade terminals (bottom) P - PC board pins 8 - Wire leads Series EEJ - Enhanced EMI Inlet Filter EJS - EEJ in Snap-in Mounting EJH - Enhanced Medical Inlet Filter EJHS - EJH in Snap-in Mounting EJM - Extended Performance Medical Inlet Filter EJMS - EJM in Snap-in Mounting Current Rating 1, 3, 6, 10, 15 or 20A Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord FA601: Insulating Shroud .413 Dia. 10.5 .271 Dia. 6.9 .118 3.0 1.39 35.4 1.17 29.7 .767 19.5 EEJ Models 1EEJ1 1EEJ2 1EEJP 1EEJ8 3EEJ1 3EEJ2 3EEJP 3EEJ8 6EEJ1 6EEJ2 6EEJP 6EEJ8 10EEJ1 10EEJ2 10EEJP 10EEJ8 15EEJ1 15EEJ2 15EEJP 15EEJ8 20EEJ1 20EEJ8 EJS Models 1EJS1 1EJS8 3EJS1 3EJS8 6EJS1 6EJS8 10EJS1 10EJS8 15EJS1 15EJS8 20EJS1 20EJS8 EJM Models 1EJM1 1EJM8 3EJM1 3EJM8 6EJM1 6EJM8 10EJM1 10EJM8 15EJM1 15EJM8 EJH Models 1EJH1 1EJH2 1EJHP 1EJH8 3EJH1 3EJH2 3EJHP 3EJH8 6EJH1 6EJH2 6EJHP 6EJH8 10EJH1 10EJH2 10EJHP 10EJH8 15EJH1 15EJH2 15EJHP 15EJH8 20EJH1 20EJH8 EJHS Models 1EJHS1 1EJHS8 3EJHS1 3EJHS8 6EJHS1 6EJHS8 10EJHS1 10EJHS8 15EJHS1 15EJHS8 EJMS Models 1EJMS1 1EJMS8 3EJMS1 3EJMS8 6EJMS1 6EJMS8 10EJMS1 10EJMS8 15EJMS1 15EJMS8 154 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series (continued) Including the EJH/EJHS, EJM/EJMS and EJS Models Case Styles EEJ1, EJH1 & EJM1 (1-15A) EEJ8, EJH8 & EJM8 (1-15A) Blue C Green/Yellow D E B Brown D E B A A A B EJS8, EJHS8 & EJMS8 (1-15A) Blue B Brown A C max. D B A E Green/Yellow D E (1-15A) 3 Power Inlet Filters & Power Entry Modules D E EEJP & EJHP C C EEJ2 & EJH2 (1-15A) 0.96 24.39 max. 0.96 24.39 C EJS1, EJHS1 & EJMS1 20EEJ1 & 20EJH1 (1-15A) C C D E A B D E A B 155 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series (continued) Including the EJH/EJHS, EJM/EJMS and EJS Models Case Styles (continued) Recommended Panel Cutouts 1 to 15A EEJ, EJH & EJM Front Mount 20EJS1 Back Mount .820 20.8 C .900 22.9 F .140 3.56 1.200 30.48 A D E 1.575 40.01 B .140 3.56 1.200 30.48 1.575 40.01 .12 R. 3.05 Typ. .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted 20A EEJ & EJH Front Mount Back Mount 1.055 26.8 20EEJ8 & 20EJH8 C .985 25.02 .138 3.51 1.370 34.8 1.654 42.0 1.654 42.0 .118 R. 3.0 Typ. Blue .138 3.51 1.300 33.0 .125 R. 3.18 Typ. Green/Yellow D E B Brown Tolerances .005 [0.13] unless otherwise noted F 1 to 15A EJHS, EJMS & EJS A 0.188 Max. 4.775 R G 0.815 20.70 Tolerance .002 [.050] 20A EJS 1.450 36.83 20EJS8 R 0.125 Max. 3.175 C 1.053 26.75 Blue Green/Yellow D E Brown B F Tolerance .002 [.050] PC Board Layout A 0.075 1.91 0.520 13.21 .685* 17.40* 0.551 13.99 *.015 [0.38] 156 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series Including the EJH/EJHS, EJM/EJMS and EJS Models Case Dimensions Part No. B C D E F Performance Data Typical Insertion Loss Measured in closed 50 Ohm system EEJ & EJS Models 1A 3A db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 0 0.1 1 10 30 Frequency in MHz 0 0.1 6A 10A db 100 db 100 90 90 80 70 60 50 50 40 40 30 30 20 20 10 10 30 Frequency in MHz 1 10 30 Frequency in MHz 1 10 30 Frequency in MHz 10 0.1 1 10 30 Frequency in MHz 0 0.1 15A 20A db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 80 70 60 0 3 10 10 Power Inlet Filters & Power Entry Modules A EJM1 1-10A EEJ2, EJH2 15A EEJ2, EJH2 1-10A EEJP, EJHP 15A EEJP, EJHP EJS1, EJHS1 EJMS1 EEJ8, EJH8 EJM8 EJS8, EJHS8 EJMS8 20EEJ1, 20EJH1 20EJS1 20EEJ8, 20EJH8 20EJS8 EEJ1, EJH1 (continued) 10 0.1 1 10 30 Frequency in MHz 0 0.1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 20EJS1 3EJS1 157 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series (continued) Including the EJH/EJHS, EJM/EJMS and EJS Models Performance Data (continued) Typical Insertion Loss Measured in closed 50 Ohm system EJH & EJHS Models 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 15A 20A db 100 db 100 90 90 80 10 30 Frequency in MHz 1 10 30 Frequency in MHz 0 10 0 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 1 10 0.1 1 10 30 Frequency in MHz 0 0.1 EJM & EJMS Models 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 15A db 100 90 80 70 60 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz 158 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Cost-effective Medium Performance Power Inlet Filter EEJ Series (continued) Including the EJH/EJHS, EJM/EJMS and EJS Models Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) Power Inlet Filters & Power Entry Modules 3 EJM & EJMS Models EJM1 EJMS1 159 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide EMI Power Inlet Filter EF Series EF8 UL Recognized CSA Certified VDE Approved* EF1F / EF1FC EF4 EF2F EF Series Specifications * Compact single stage EMI filter with IEC 60320-1 C14 inlet * Two element circuit provides basic attenuation Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: .21 mA @250 VAC 50 Hz: .36 mA * Available with an internal ground-circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies Hipot rating (one minute): Line to Ground: Line to Line: * Superseded by the EEA Series Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Ordering Information 3 EF 1F C 2250 VDC 1450 VDC Rated Current: 1 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ground Circuit Inductor Omit if none Output Styles 1F - .250 [6.3] spade terminals Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord (back) 2F - .250 [6.3] spade terminals (bottom) 4 - Wire leads (bottom) 8 - Wire leads (back) EF Series FA601: Insulating Shroud Current Rating 1, 3, 6, 10 or 15A .413 Dia. 10.5 .271 Dia. 6.9 Available Part Numbers 1EF1F 3EF1F 6EF1F 10EF1F 15EF1F 1EF2F 3EF2F 6EF2F 1EF4 3EF4 6EF4 Ground Circuit Inductor Versions 10EF1FC .118 3.0 1EF8 3EF8 6EF8 1.39 35.4 1.17 29.7 .767 19.5 *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC 160 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide EMI Power Inlet Filter (continued) EF Series Electrical Schematic LINE LOAD EF8 1 F Blue Green/Yellow D E B Brown F Note 1: C Suffix (Ground Choke) Versions only A Case Styles EF1F & EF1FC C C D E A 3 B Case Dimensions C .65 Max. 16.5 A B EF4 C C 1EF2F, 3EF2F, 6EF2F 1EF4, 3EF4, 6EF4 1EF8, 3EF8, 6EF8 10EF1F, 10EF1FC 15EF1F E F .820 20.8 F 1.200 30.48 1.575 40.01 F Back Mount Blue Brown A Front Mount B D Recommended Panel Cutouts Green/Yellow D E B 1EF1F, 3EF1F, 6EF1F EF2F D E A Part No. Power Inlet Filters & Power Entry Modules .900 22.9 .140 3.56 .062 R. 1.58 Typ. 1.200 30.48 1.575 40.01 .140 3.56 .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted 161 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide EMI Power Inlet Filter (continued) EF Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1EF 3EF 6EF 10EF db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 15EF db 100 90 80 70 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 60 50 40 30 20 10 0 0.01 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) 162 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Inlet Filter EJT Series UL Recognized CSA Certified VDE Approved* EJT8 EJT1 EJT Series Specifications * Superior EMI filter with IEC 60320-1 inlet * Double three element differential mode circuit attenuates noise up to 1GHz * Up to 15A with IEC 60320-1 C14 inlet * 20A rating with IEC 60320-1 C20 inlet * Spade terminals or wire leads Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 6 EJT 1 Output Styles 1 - .250 [6.3] spade terminals 8 - Wire leads 3 2250 VDC 1450 VDC Power Inlet Filters & Power Entry Modules Ordering Information Maximum leakage current each Line to Ground: 1-15A 20A @ 120 VAC 60 Hz: .25 mA .22 mA @250 VAC 50 Hz: .43 mA .40 mA 1 to 20A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 EJT Series Accessories Current Rating 1, 3, 6, 10, 15 or 20A GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Available Part Numbers 1EJT1 3EJT1 6EJT1 10EJT1 15EJT1 20EJT1 1EJT8 3EJT8 6EJT8 10EJT8 15EJT8 20EJT8 FA601: Insulating Shroud (fits 1-15A only) .413 Dia. 10.5 .271 Dia. 6.9 .118 3.0 *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC. 20A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 16A, 250VAC. 1.39 35.4 1.17 29.7 .767 19.5 163 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Inlet Filter (continued) EJT Series Electrical Schematics 20EJT8 LINE LOAD Blue 1 Green/Yellow D E Brown B 1 A Note 1: 20A Versions only Case Styles C EJT1 C B D E Case Dimensions A 20EJT1 EJT1 EJT8 C 20EJT1 B D E A EJT8 Blue Green/Yellow D E B A B C D E Part No. 20EJT8 Recommended Panel Cutouts 1 to 15A 20A 1.575 40.00 1.654 42.01 1.20 30.48 1.370 34.80 Brown .820 20.83 0.140 Dia. 3.56 R 1.055 26.80 .062 Max. 1.57 0.138 Dia. 3.51 R .062 Max. 1.57 A Front Mount Only Tolerance .005 [.13] C 164 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide High Performance Power Inlet Filter (continued) EJT Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 1EJT 3EJT 6EJT 10EJT db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 0 100 1000 Frequency in MHz 0.1 15EJT 20EJT db 100 db 100 90 90 80 80 70 60 60 50 50 40 40 30 30 20 20 10 0 10 100 1000 Frequency in MHz 0 10 0.1 1 10 0 100 1000 Frequency in MHz 0.1 1 10 100 1000 Frequency in MHz 3 Power Inlet Filters & Power Entry Modules 70 1 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 0.1 1 10 0 100 1000 Frequency in MHz 0.1 1 10 100 1000 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 165 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Smallest Power Entry Module with Metric Fuse Holders GG & HG Series UL Recognized CSA Certified VDE Approved GG1 GG8 GG Series Specifications * Power entry module with enhanced EMI filter * Single or dual fusing * Two element circuit provides basic attenuation * Available with an internal ground-circuit inductor (C versions) to isolate equipment chassis from power line ground at radio frequencies * Multiple termination and mounting styles HG Series * Medical version of our GG Series * Mechanically identical to GG Series Maximum leakage current each Line to Ground: HG Models GG Models @ 120 VAC 60 Hz: 2 A .25 mA @250 VAC 50 Hz: 5 A .42 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 1 to 10A Required Fuse(s): 5 x 20mm (not included) * Available only with dual fusing Ordering Information 3 E GG 1 C -2 Metric Fuse Holders 1 - Single 2 - Double Ground Circuit Inductor Omit if none Output Styles 1 - .250 [6.3] spade terminals 8 - Wire leads GG or HG Series (Flange mount) GGS or HGS Series (Snap-in mount) Leakage current designation E - Low leakage (<0.5 mA) Current Rating 1, 3, 6 or 10A Available Part Numbers Filtered modules 1EGG1-1 3EGG1-1 6EGG1-1 10EGG1-1 1EGG1-2 3EGG1-2 6EGG1-2 10EGG1-2 1EGG8-1 3EGG8-1 6EGG8-1 10EGG8-1 1EGG8-2 3EGG8-2 6EGG8-2 10EGG8-2 1EGS1-1 3EGS1-1 6EGS1-1 10EGS1-1 1EGS1-2 3EGS1-2 6EGS1-2 10EGS1-2 Filtered modules with ground circuit inductor 1EGG1C-1 3EGG1C-1 6EGG1C-1 1EGG1C-2 3EGG1C-2 6EGG1C-2 1EGG8C-1 3EGG8C-1 6EGG8C-1 1EGG8C-2 3EGG8C-2 6EGG8C-2 Medical filter modules 1EHG1-2 3EHG1-2 6EHG1-2 10EHG1-2 1EHG8-2 3EHG8-2 6EHG8-2 10EHG8-2 1EHGS1-2 3EHGS1-2 6EHGS1-2 10EHGS1-2 166 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Smallest Power Entry Module with Metric Fuse Holders (continued) GG & HG Series Electrical Schematic GG8 & HG8 LINE LOAD 1 Blue 2 3 Green/Yellow B D E Brown 3 Note 1: Second fuse only in -2 version Note 2: C versions only Note 3: not present in HG versions A C Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord 3 Part No. Case Styles GG1 & HG1 GG1, GG1C & HG1 GG1C GS1, HGS1 C GG8, HG8 D E A A B C D E B Power Inlet Filters & Power Entry Modules Case Dimensions Recommended Panel Cutouts GG / HG GS / HGS 1.14 29.0 1.24 31.5 GS1 & HGS1 1.29 32.8 1.30 33.0 D E C A 1.417 36.0 B Front or Back Mount Front Mount Only 167 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Smallest Power Entry Module with Metric Fuse Holders (continued) GG & HG Series Performance Data Typical Insertion Loss GG & GS Models Measured in closed 50 Ohm system 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 70 70 70 70 60 60 60 60 80 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 3A GG1C 6A GG1C db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz HG Models 1A 3A 6A 10A db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 1 10 30 Frequency in MHz 0 0.1 1 Minimum Insertion Loss 10 30 Frequency in MHz 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 0 168 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Line Filter for Medical Equipment H Series UL Recognized CSA Certified VDE Approved* EH8 EH9 EH4 EH1 H Series EH5 Specifications * Minimal leakage current suitable for medical equipment * Two element circuit provides basic EMI attenuation above 1 MHz * Available with an internal ground circuit inductor (C suffix versions) to isolate equipment chassis from power line ground at radio frequencies * Capacitive output (see EAH, EBH and EJH Series for capacitive input) Ordering Information 3EH1C Ground Circuit Inductor Omit if none Hipot rating (one minute): Line to Ground: Line to Line: Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 15A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Electrical Schematic LINE Output Styles Chassis Mount Style 1 - .250 [6.3] spade terminals 3 - Wire leads Power Inlet Style * 4 - .250 [6.3] spade terminals (back) 5 - Wire leads (bottom) 8 - Wire leads (back) 9 - .250 [6.3] spade terminals (bottom) H Series Leakage current designation E - Low Leakage (<0.5 mA) Current Rating 3, 6, 10 or 15A 3 2250 VDC 1450 VDC Power Inlet Filters & Power Entry Modules * Flanged mounting the same as the EC, ED and EF Series Maximum leakage current each Line to Ground: @ 120 VAC 60 Hz: 2 A @250 VAC 50 Hz: 5 A LOAD 1 Note 1: 10EH4C version only Available Part Numbers 3EH1 3EH3 6EH1 6EH3 6EH4 6EH5 6EH8 6EH9 10EH1 10EH3 10EH4 15EH4 Ground Circuit Inductor Versions 10EH4C *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC *IEC 60320-1 C14 inlet mates with C13 connector 169 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Line Filter for Medical Equipment (continued) H Series Case Styles H1 (Chassis Mount) H5 E A Blue Brown D D E B Green/Yellow C B F C A H3 F (Chassis Mount) H8 F Blue E D B Green/Yellow D E B Brown F A A C C H4 & H4C C D E A B Recommended Panel Cutouts Front Mount .820 20.8 H9 1.200 30.48 1.575 40.01 C .65 Max. 16.5 D E A Back Mount .900 22.9 .140 3.56 .062 R. 1.58 Typ. 1.200 30.48 1.575 40.01 .140 3.56 .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted B 170 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Line Filter for Medical Equipment (continued) H Series Case Dimensions Part No. H1 H3 6EH4 10EH4, 10EH4C 15EH4 H5 H8 A B C F E D Typical Insertion Loss Measured in closed 50 Ohm system 3EH 6EH db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 10EH 15EH db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 10 0 3 Power Inlet Filters & Power Entry Modules H9 Performance Data 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Accessories GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) FA601: Insulating Shroud .413 Dia. 10.5 .271 Dia. 6.9 .118 3.0 1.39 35.4 1.17 29.7 .767 19.5 171 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Voltage Selection and Fusing J Series UL Recognized CSA Certified Front View, all models 6J4 6HJ4 J Series Specifications * Power entry module with North American style 3AG fuse holder * 2 or 4 voltage selection * Compact snap-in design * Two element circuit provides basic EMI attenuation * Available with minimal leakage current suitable for medical applications (HJ models) * Also available without filter (VJ models) Maximum leakage current each Line to Ground: 6HJ4 or 6J4 Models non-filtered @250 VAC 50 Hz: 500 A 5 A Hipot rating (one minute): Line to Ground: Line to Line: Operating Voltage: suffix - 1 or - 4 models: suffix - 2 models: 1550 VAC 1450 VDC 100, 120, 220 or 240VAC 115 or 230 VAC Operating Frequency: Ordering Information 50/60 Hz Rated Current: 6A Required Fuse: .25 x 1.25 (not included) 6 H J 4 -4 Available Voltage Selections 1 - Four (non-filtered versions) 2 - Two 4 or blank - Four (filtered versions) Filtered Indicator 1 - Non-filtered 4 - Filtered Available Part Numbers J Series Filter Type H - Medical V - Non-filtered Blank - general purpose Non-filtered models 6VJ1 6VJ1-2 General Purpose Filters 6J4 6J4-2 Medical Filters Current Rating 6A 6HJ4-4 6HJ4-2 172 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Power Entry Module with Voltage Selection and Fusing (continued) J Series Electrical Schematics 6VJ1 & 6VJ1-2 Accessories GA400:NEMA 5-15P to IEC 60320-1 C-13 line cord Note 3 Power On/Off Off R S H On Pilot light Ground A A B B 20V 100V J C D D K E L F Transformer primary 120V M Note 2 Neutral P 220V 240V 120V 100V Note 2 Hot Note 1 N JA302: 2 Voltage Select Card Comes standard with 6VJ1-2, 6J4-2 and 6HJ4-2 6J4 & 6J4-2 Note 3 220V 240V 120V 100V A Hot Ground Neutral B C C D D E E F F Transformer primary JA403: Mounting clips for .105 - .125" panels 120V JA410-419: Equipment Rating Labels Self-adhesive, available in multiples of 40 Specify part number 6HJ4-4 & 6J4-2 2.330 Note 3 220V 240V 120V 100V A Neutral J H Note 1 Fuse A B B C C A 100V Pilot light On .210 Line V. + 5 - 10% 48-440 - 50 VA Max. 100/120V (115V) 220/240V (230V) 500mA 250mA B C 20V Power On-Off Off Ground Power Inlet Filters & Power Entry Modules J H Note 1 Hot 3 Comes standard with 6VJ1, 6J4 and 6HJ4-4 B 100V Pilot light On JA304: 4 Voltage Select Card A 20V Power On-Off Off D D E E F F Transformer primary A 120V Voltage Selection Part No. JA410 JA411 JA412 JA413 JA414 JA415 JA416 JA417 JA418 JA419 B VA max. 25 50 100 200 250 300 400 500 600 Assortment C Fuse Fuse 100/120 (115) 220/240 (230) 250 mA 500 mA 1A 2A 2.5A 3A 4A 5A 6A 125 mA 250 mA 500 mA 1A 1.25A 1.5A 2A 2.5A 3A JA410-JA418: 40 labels of one part number JA419: 5 each of JA410 - JA418 (45 labels) Open cover door and slide fuse-pull lever to left. Select operating voltage by orienting voltage selection card with the desired voltage on top left side. Push card firmly into module slot. Slide fuse-pull lever to right into normal position and re-insert fuse into holders. JA500: Voltage Selector Card Extractor Tool Use caution in selecting correct fuse value. 173 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Power Entry Module with Voltage Selection and Fusing (continued) J Series Case Styles Case Dimensions Part No. Non-filtered Models 6VJ1, 6VJ1-2 C B C D D B A 6J4, 6J4-2, 6HJ4-4, 6HJ4-2 A Performance Data Typical Insertion Loss Measured in closed 50 Ohm system Filtered Models 6J4 6HJ4 db 100 db 100 90 90 80 C D B A 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Recommended Panel Cutouts Door Open Position Minimum Insertion Loss 1.063* 1.17 27.0 29.7 Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Bezel Clearance 2.60* 66.0 * .003 [.076] 2.68 68.1 3.00 76.2 174 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Configuration Power Entry Module L Series UL Recognized CSA Certified VDE Approved EDL4C / EHL4C EDL1S / EHL1S L Series Specifications * Power entry module with switch or fuse * For 10A capability and high performance filtering see the P Series on page 192 * Two element circuit provides extended EMI attenuation similar to EAB inlet filter * North American or metric fuse holders Ordering Information 6EDL1SCM Fuseholder Type (pre-installed) M - Metric Omit for North American Mounting Type C- Snap-In Omit for flange mount Hipot rating (one minute): Line to Ground: Line to Line: Operating Voltage: 1S & 1SC models (fixed): 4 & 4C Suffix: Operating Frequency: Rated Current: 250 VAC max. 100, 120, 220 or 240 VAC. 50/60 Hz 2 to 6A Required Fuse(s): North American: Metric: Switch: 3 2250 VDC 1450 VDC Power Inlet Filters & Power Entry Modules * Available with minimal leakage current for medical applications (HL models) Maximum leakage current each Line to Ground: DL Models HL Models @ 120 VAC 60 Hz: .25 mA 2 A @ 250 VAC 50 Hz: .50 mA 5 A one .25 x 1.25"(not included) two 5 x 20mm (not included) DPST 10,000 operations at 51A max. inrush Switch Option S - DPST on/off switch Omit for none Voltage Selection Positions 1 or 4 L Series Filter Type D - General Purpose H - Medical omit for none Leakage current designation E - Low Leakage (<0.5 mA) Current Rating 2, 4 or 6A 175 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Configuration Power Entry Module (continued) L Series North American Fusing Metric Fusing Available Part Numbers Flange Mount Snap-In Flange Mount Snap-In Single Voltage, Switched 6EL1S 6EL1SC 6EL1SM 6EL1SCM 4 Voltage Select, No Switch 6EL4 6EL4C 6EL4M 6EL4CM 2EDL1S 2EDL1SC 2EDL1SM 2EDL1SCM 4EDL1S 4EDL1SC 4EDL1SM 4EDL1SCM 6EDL1S 6EDL1SC 6EDL1SM 6EDL1SCM 2EDL4 2EDL4C 2EDL4M 2EDL4CM 4EDL4 4EDL4C 4EDL4M 4EDL4CM 6EDL4 6EDL4C 6EDL4M 6EDL4CM Single Voltage, Switched 6EHL1S 6EHL1SC 6EHL1SM 6EHL1SCM 4 Voltage Select, No Switch 6EHL4 6EHL4C 6EHL4M 6EHL4CM Non-Filtered Single Voltage, Switched General Purpose Filter 4 Voltage Select, No Switch Medical Filter Voltage Selection Recommended Panel Cutouts .06 R 1.52 (3) (4) To change selected voltage: disconnect the power cord; open cover using a small blade screwdriver or similar tool; insert the tool into the voltage selection slot and remove wheel from unit; select desired voltage; replace wheel into unit and close cover, making sure the selected voltage appears in connector window. 2.201* 55.91 (2) 2.213* 56.21 (3) .020 R .508 1.122* 28.50 1.575 (3) 40.00 (1) *+.008 -.00 +.203 -.00 176 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Configuration Power Entry Module (continued) L Series Electrical Schematics Accessories DL Models GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Single Voltage, Switched (DL1S) Note 1 Neutral Customer Transformer Primaries Note 2 H On/Off Ground Hot 2 (1) 1 (1a) (2) 4 (2a) 3 Device LA303: Voltage Select Wheel, 3 position Selection drum for use with L4 models. Marked with 110V, 220V and 240V G 4 Voltage Select, No-Switch (DL4) Customer 120V 100V Note 1 Hot G Note 2 On/Off A 220V Transformer 240V Primaries A A 20V B B B C C C LA304: Voltage Select Wheel, 4 position 3 Selection drum for use with L4 models. Marked with 100V, 110V, 220V and 240V. One LA304 comes standard with each L4 model. 100V Neutral D D D E E E F F F Power Inlet Filters & Power Entry Modules Ground 120V H HL Models LA400: Blank insert Single Voltage, Switched (HL1S) Customer Note 1 Neutral Note 2 H On/Off Ground Hot 2 (1) 1 (1a) (2) 4 (2a) 3 Transformer Primaries Blank to replace switch in single voltage models LA601: Insulating Boot Plastic shroud to cover back of module to prevent inadvertent access Device G Replacement Fuse Holders 4 Voltage Select, No-Switch (HL4) Customer 120V 100V Hot Note 1 G Note 2 On/Off A 220V Transformer 240V Primaries A Neutral Accommodates one .25 x 1.25" fuse A 20V B B B C C C D D D E E E F F F 100V Ground LA200: North American Fuseholder LA201: Metric Fuseholder Accommodates one 5 x 20mm metric fuse 120V H 177 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Configuration Power Entry Module (continued) L Series Case Styles Flange Models, Non-filtered Snap-in Models, Non-filtered 3 4 1 2 G A H .221 5.61 C D F A E .221 5.61 E Flange Models, Filtered Snap-in Models, Filtered 3 4 1 2 G H A C B G C D .221 5.61 F H F B A E D G C D F B A C B E F D H C D E F A .221 5.61 E Case Dimensions A Model No. Flange Unfiltered Snap-in Unfiltered Flange Filtered Snap-in Filtered B C D E F 178 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Dual Configuration Power Entry Module (continued) L Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 2EDL 4EDL 6EDL db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 0 10 30 Frequency in MHz 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 3 6EHL db 100 90 Power Inlet Filters & Power Entry Modules 80 Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) 70 60 50 40 30 20 10 0 0.1 1 10 30 Frequency in MHz Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 179 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Enhanced EMI Filtering LA Series UL Recognized CSA Certified LA Series Specifications * Power entry module with extended and enhanced low frequency filters * North American or dual metric fuse holder options * DPST on/off switch * 120/240V voltage selection * The F version provides basic performance two element circuit filter * The X version provides a three element differential mode circuit with extended EMI attenuation, suitable for meeting FCC Part 15J, Class B conducted emissions limits * The Z version provides a three element differential mode circuit with enhanced EMI low frequency attenuation, suitable for meeting EN55022 Level B as well as FCC Part 15J limits Maximum leakage current each Line to Ground: XLA or FLA Model ZLA Model @120 VAC 60 Hz: .25 mA .30 mA @250 VAC 50 Hz: .50 mA .50 mA Hipot rating (one minute): Line to Ground: Line to Line: 2250 VDC 1450 VDC Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Rated Current: 3 to 5A Required Fuse(s): Switch: one .25 x 1.25"(not included) or two 5 x 20mm (not included) DPST 10,000 operations at 51A max. inrush Ordering Information 5 E F LA 2S Case Style 2S - IEC inlet*, selectable fuse holder, DPST switch, spade terminals Available Part Numbers LA Series Filter Type F - General purpose X - High performance Z - Premium performance 5EFLA2S 3EXLA2S 3EZLA2S Leakage current designation E - Low Leakage (<0.5 mA) Current Rating 3A or 5A *IEC 60320-1 C14 inlet mates with C13 connector 180 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Enhanced EMI Filtering (continued) LA Series Voltage Selection Case Styles To change selected voltage: remove the fuse cartridge using a small blade screwdriver or similar tool; select the desired voltage by matching the arrow on the fuse cartridge to the arrow located on the front of the unit (lower right corner); replace the fuse cartridge making sure the voltage selection arrow aligns with the arrow located on the front of the unit. A F B D C B C A D E F E Changing Fuses 3 Case Dimensions A Part No. 5EFLA2S 3EXLA2S Electrical Schematics 3EZLA2S B C D E F Power Inlet Filters & Power Entry Modules Remove the fuse cartridge using a small blade screwdriver or similar tool; for Metric fusing pull out the sliding fuse covers located at the top of each fuse compartment; insert desired fuses; push the sliding fuse covers back in place and insert the fuse cartridge back into the unit making sure the voltage selection arrow aligns with the arrow located on the front of the unit. (Note: Single North American or Metric fuse placement is always on the side of the desired voltage selection arrow behind the fuse symbol; the other compartment may be used as a spare or be left blank. Dual Metric fusing capability is available for 220/240 volts only.) FLA Model 120V Power on/off 240V A or D A A B B 120V Neutral Recommended Panel Cutout C Ground D D E E F F .093R 2.36 120V Phase G Customer Transformer Primaries 2.42* 61.47 XLA & ZLA Model 120V On/Off 240V A or D A A B B .140 Dia. 3.56 120V Neutral 1.19* 30.23 C Hot D D E E F F G * +.020 - .00 + 0.5 - .00 1.57 39.88 120V Customer Transformer Primaries 181 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Entry Module with Enhanced EMI Filtering (continued) LA Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 5EFLA2S 3EXLA2S 3EZLA2S db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 0 10 30 Frequency in MHz 10 0.01 0.1 1 0 10 30 Frequency in MHz 0.01 0.1 1 10 30 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 182 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options M Series UL Recognized CSA Certified VDE Approved XM / ZM VM Ordering Information 5EFM4SC Mounting Type C- Snap-In Omit for flange mount Voltage Selection Positions 1 or 4 M Series Filter Type F - General purpose H - Medical X - High performance Z - Premium performance V - Non-filtered Leakage current designation E - Low leakage (<0.5 mA) (Filtered models only) Current Rating @120 VAC 3, 5 or 6A * Family of slim power entry modules that consume minimal depth behind panel * Four compact modules each provide a different option combination 3 * Available non-filtered or with one of four filter circuits designed to meet a wide variety of applications * Optional voltage selector configured for either 2 or 4 voltage selection Power Inlet Filters & Power Entry Modules Switch Option S - DPST on/off switch Omit for none M Series * Optional DPST on/off switch * Included fuseholder accepts either single 3AG fuse or dual metric fuses * Snap-in or flange mounting styles Filter Types H Models provide a basic performance dual element circuit EMI filter with minimal leakage current, suitable for medical applications, with attenuation similar to the EAH Series power inIet filter. F Models provide a basic performance dual element circuit EMI filter, with attenuation similar to the EEA Series Power Inlet Filter. X Models provide a high performance three element differential circuit filter, with extended EMI attenuation similar to the X Series chassis filter, suitable for bringing most digital equipment (including switching power supplies) into compliance with FCC Part 15J, Class B conducted emissions limits. Z Models provide a premium performance three element differential circuit filter, with enhanced EMI low frequency attenuation similar to the P Series Z models, suitable for bringing most digital equipment (including switching power supplies) into compliance with EN55022 Level B as well as FCC Part 15J. For minimum panel footprint, see the P series on page 192. 183 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Specifications Accessories Maximum leakage current each Line to Ground: HM FM XM/ZM @ 120 VAC 60 Hz: 2 A .25 mA .30 mA @250 VAC 50 Hz: 5 A .50 mA .50 mA GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord Hipot rating (one minute): Line to Ground: Line to Line: Line to Load (switch off) non-filtered: 2250 VDC 1450 VDC 2500 VAC Rated Voltage (max.): 250VAC Operating Frequency: 50/60 Hz Rated Current @ 120 VAC: Rated Current @ 250 VAC: 3A models: 5A models: 6A Switched models: 6A non-switched models: Required Fuse(s): Switch: MA100: Power interconnect assembly For voltage select models. 8.5" wire leads 3 to 6A 2A 4A 5A 6A Reversible fuseholder accepts one .25 x 1.25" (not included) or two 5 x 20mm (not included) DPST 100,000 operations at 70A max. inrush MA101: Plug only MA102: Strip of 100 pins for use with MA101 MA104: Individual pins for use with MA101 MA302: Two Voltage Selection Card Marked 120V/240V. One card comes standard with every 2 voltage M series module MA304: Four Voltage Selection Card Marked 100V/120V/230V/240V. One card comes standard with every 4 voltage M series module Available Part Numbers Non-Filtered Models 5EFM1S 5EFM1C 5EFM1SC 5EFM4S 5EFM4C 5EFM4SC 0 0 0 2 5EFM1 5EFM4 6VM4SC 1 1 1 4 6VM1SC 0 6VM1 6VM1S 6VM1C 6VM2 6VM2S 6VM4 6VM4S 6VM4C General Purpose Filters 4 1 2 4 3 Snap-In 2 Flange Mount 2 Voltage Selections MA400: Medical safety bracket assembly Prevents inadvertent removal of fuse(s) Medical Filters 1 4 5EHM1 5EHM4 5EHM1S 5EHM4S High Performance - FCC-B 1 4 3EXM4 3EXM1S 3EXM4S Premium Performance - EN55022-B 1 4 3EZM4 MA401: Bracket only MA402: Standoff only 3EZM1S 3EZM4S 184 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Accessories (continued) Fuse Installation Instructions MA601 - 604: Insulating Boot Plastic shroud for back of M series to prevent inadvertent access to connections 1. Remove power cord 2. Insert a pocket screwdriver at point "X" as shown A MA601: Fits M4S versions MA602: Fits M1S versions MA603: Fits M4 versions MA604: First M1 versions USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES "X" A 3 Section A-A 3. Gently lift the entire door UP approximately 1/4" (minimum) Once lifted, the door will pivot on it's hinges to expose the fuse holder Voltage Selection Power Inlet Filters & Power Entry Modules 1. Open cover, using small blade screwdriver or similar tool (see illustration on right) Lift Up 2. Set aside cover/fuse block assembly 3. Pull voltage selector card straight out of housing, using indicator pin 4. Orient selector card so that desired voltage is readable at the bottom 4. When the fuse holder is installed in the single fuse position, apply the screwdriver as shown and gently lift up Use screwdriver as shown, do not use fingers NOT here 5. Orient indicator pin to point up when desired voltage is readable at bottom (note that when indicator pin is fixed, successive voltages are selected by rotating the card 90 clockwise) 6. Insert voltage selector card into housing, printed side of card facing forward toward IEC connector and edge containing the desired voltage first 7. Replace cover, and verify that indicator pin shows the desired voltage Insert Here When the fuse holder is installed in the dual fuse position, it will normally release as soon as the door is opened 5. Install one (1) AG fuse or two (2) metric fuses (see below) 6. Replace fuse holder into housing 7. Swing and push to snap door back in place 4 0 0 0 2 3 2 0 1 1 0 2 120V 1 0 2 1 0 0 0 3 0 2 1 4 0 100V 3 0 230V 0 2 4 2 1 0 3 2 0 2 2 0 1 Fuse Options 2 4 0 240V North American single fuse installation Metric dual fuse installation Install fuses on one side only, do not install both AG and metric fuses at the same time 185 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Electrical Schematics Non-Filtered Models VM1 Neutral Filtered Models FM1 & HM1 Power On/Off Note 3 Power On/Off Note 2 K Neutral K H B J F Note 1 Note 2 Note 3 120V Hot G Phase L L Customer Transformer Primaries VM2 FM4 & HM4 Power On/Off Note 3 Neutral G 240V 120V H K Note 2 B 120V 100V A A 120V B Note 1 Neutral C C D Power On/Off Note 2 Note 1 120V J L Note 1 E E F F G 120V 100V C D D E E F F J L Phase 230V 240V A Note 4 G 120V Customer Transformer Primaries Power On/Off A 20V 100V Hot C XM1 & ZM1 Power On/Off Note 3 Neutral Note 4 Note 3 F VM4 20V 100V B 120V Customer Note 4 Transformer Primaries A A H K D 120V Hot 230V 240V H K Note 2 Note 2 Neutral H B J F Note 1 B Note 1 J L Note 1 C C D D E E F G 120V F Phase G Customer Transformer Primaries XM4 & ZM4 120V 100V Power On/Off Note 2 Neutral A A 20V Note 4 H K 100V B Note 1 Phase J L Note 4 230V 240V C C D D E E F F G 120V Customer Transformer Primaries 186 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Non-filtered Models 6VM1 USE ONLY WITH 250V FUSES 6VM2 & 6VM4 USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D C D E B B A A 100V 120V 230V 240V 6VM1C 6VM4C USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C 100V 120V 230V 240V 3 C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D E Power Inlet Filters & Power Entry Modules D E A A 6VM1S 6VM2S & 6VM4S USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D 100V 120V 230V 240V C D B B E A A 6VM1SC 6VM4SC USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C B E E A A C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D 100V 120V 230V 240V 187 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models 3EXM1S & 3EZM1S G 3EXM4S & 3EZM4S G Threaded Insert Threaded Insert 1.17* 29.7 1.13* 28.7 1.88* 47.8 3.09 Max. 78.49 USE ONLY WITH 250V FUSES 1.88* 47.8 3.09 Max. 78.49 USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES C D D E E B B *.020 [.508] A *.020 [.508] A 100V 120V 230V 240V DISCONNECT POWER BEFORE REPLACING FUSES 3EXM4 & 3EZM4 5EHM1 & 5EFM1 G Threaded Insert USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES 1.13* 28.7 D 1.88* 47.8 3.09 Max. 78.49 USE ONLY WITH 250V FUSES 100V 120V 230V 240V E B A C DISCONNECT POWER BEFORE REPLACING FUSES D E B A *.020 [.508] 188 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models (continued) 5EFM1C USE ONLY WITH 250V FUSES 5EHM4 & 5EFM4 USE ONLY WITH 250V FUSES C 100V 120V 230V 240V C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D A E D E B A 5EHM1S & 5EFM1S 3 5EFM4C C USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES E D 100V 120V 230V 240V C D A B Power Inlet Filters & Power Entry Modules USE ONLY WITH 250V FUSES E A 5EFM1SC 5EHM4S & 5EFM4S USE ONLY WITH 250V FUSES USE ONLY WITH 250V FUSES C DISCONNECT POWER BEFORE REPLACING FUSES DISCONNECT POWER BEFORE REPLACING FUSES D A D B E 100V 120V 230V 240V C E A 189 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Case Styles - Filtered Models (continued) 5EFM4SC USE ONLY WITH 250V FUSES DISCONNECT POWER BEFORE REPLACING FUSES 100V 120V 230V 240V C E Recommended Panel Cutouts Insert on XM and ZM .170 models only Dia. 4.32 4S Models 1.17* 29.7 1.88* 47.8 1S & 4 models 1.13* 28.7 0.13 R 3.30 Dia. .570 14.5 .170 4.32 .175 4.45 Part No. F B * .020 [.508] 1.145 29.08 A B C F G E 6VM1C 6VM1S 6VM1SC 6VM2 6VM4 6VM4C 6VM2S 6VM4S 6VM4SC 3EXM1S 3EZM1S 3EXM4 3EZM4 3EXM4S 3EZM4S 5EHM1 5EFM1 5EFM1C 5EHM1S 5EFM1S 5EFM1SC 5EHM4 5EFM4 5EFM4C 5EHM4S 5EFM4S 5EFM4SC 6VM1 D A Case Dimensions D 190 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Slim Power Entry Module Family with Multiple Options (continued) M Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system 5EHM 5EFM 3EXM 3EZM db 100 db 100 db 100 db 100 90 90 90 90 80 80 80 80 70 70 70 70 60 60 60 60 50 50 50 50 40 40 40 40 30 30 30 30 20 20 20 20 10 10 10 0 0.1 .15 1 0 10 30 Frequency in MHz 0.1 .15 1 10 30 Frequency in MHz 0 10 0.1 1 0 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz 3 Power Inlet Filters & Power Entry Modules Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 191 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint P Series UL Recognized CSA Certified VDE Approved PE filtered PS non-filtered PS filtered P Series The P series CHAMELEON power entry module offers the most popular features in a small footprint design As the first 10A module to provide all five power entry functions in one compact design, the chameleon module readily adapts to its environment and the needs of international markets. * Snap-in or flange mounting * Standard IEC 60321-1 C14 power inlet * Both North American and metric fusing capabilities * Two voltage selection options (for 4-voltage selection, see the M, L or LA Series) * Optional DPST on/off switch * Filter options for general purpose, medical and high-performance EMI filtering The CHAMELEON module's compact design and modular construction allows selection of the required power entry feature -- without altering the panel cutout. And the CHAMELEON module, with its optional adapters, will fit several common panel cutouts. Filter Types The CHAMELEON module has four filter and one non-filtered option: S models provide an extended performance two element circuit EMI filter, with attenuation similar to the EEB Series power inlet filter. It offers protection for general purpose applications with stray Line to Ground and Line to Line noise that must be attenuated at the power inlet. These filters have limited leakage current and are available in current ratings of 3, 6 and 10A. L models feature a high performance medical filter designed to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. Z models provide a high performance three element differential mode circuit filter, with extended EMI attenuation similar to the M Series Z models, to help bring most digital equipment (including switching power supplies) into compliance with EN55022, Level B (as well as FCC Part 15J, Class B) conducted emissions limits. They are available with current ratings of 6 and 10A. These high performance versions are only available with mounting ears, single voltage selection, in a complete RFI shield with options for switch, fuses and current ratings. Mounting extenders are not compatible with the L or Z models. For minimum depth behind the panel, see the M Series B models are non-filtered and incorporate an interconnection block. The block connects the voltage selection terminals of an unfiltered CHAMELEON module with an IEC connector and an optional switch to reduce external wiring. Compatible with the A or B RFI shield options. H models provide susceptibility protection with minimal leakage current, and are suitable for patient care and non-patient care medical equipment. 192 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Ordering Information Part numbers are constructed by selecting the alphanumeric character which represents the desired feature. Note: For any option where shown as "0" use the digit ZERO (0) not the letter (O). Mounting Style Extender Options1 Switch Options* Voltage Select2 Fuse Options Filter Type Filter Current Shield Options1 P S J 0 X S S 6 0 Mounting Style E = Mounting ears (Horizontal axis) S = Snap-in M = Mounting ears Switch Option 0 = Blank S = Double pole single throw (DPST) Fuse Options D = Dual fuse S = Single fuse Filter Current 0 = No filter 3 = 3A 6 = 6A X = 10A 3 (Vertical axis) Input Voltage Select 0 = Single voltage S = Dual voltage2 select (SMPS) X = Dual voltage2 select (series/parallel) Extender for J-Series or others Shield Options Filter Type 0 = No shield 0 = No filter A = Filter shield B = Interconnection B = Complete block3 Shield H = Medical Filter L = High Performance C = Complete can (for L & Z models) Medical4 S = General purpose Z = High Performance4 Power Inlet Filters & Power Entry Modules Extender Option 0 = None C = FN260 J = J Series L = L Series1 Notes: 1 L Series extender cannot be added to units with a shield. No style of extender can be added to units with B or C shields. 2 Dual voltage options are not available with L or Z Filter Types Fuse holder 3 When using the interconnection block, the last 3 digits of the part number are BX (0, A, or B) 4 High performance versions (L or Z filter types) are available with any switch or fuse option but only in 6 or 10A with horizontal (PE) or vertical (PM) mounting ears, single voltage (0), complete shield (C) and no extenders Optional switch * For alternative switch orientation options, please contact technical support or your Corcom product sales representative Optional filter The part number PS0SXSS6B would represent: P Series (P) with a snap-in mount (S) with no extender (0) a switch (S) dual voltage select (X) single fusing (S) general purpose filter (S) for 6A (6) with a B shield (B) 193 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Voltage Selection Shield Options P series power entry modules include the voltage selector integral with the fuse holder. Three voltage selection options are each supported by one of three different fuse holders. The fifth digit of the part number specifies which of the three fuse holders is included to provide the desired voltage selection. The single voltage fuse holder (option "0") has no voltage indication markings. The dual voltage options select 115V or 230V by removing the fuse holder, flipping it over, and reinstalling it. Voltage selection is indicated through a window in the P Series door. The "SMPS" fuse holder (option "S") jumpers two independent P Series terminals to indicate 230V operation to a switching mode power supply. The "PRSR" parallel/serial fuse holder (option "X") connects the windings of the equipment's dual primary transformer (not included) to step down the voltage or double up the current. The markings on the voltage selection fuse holders also remind the user to install the appropriate fuse for the current at the selected voltage. The P series offers several RF shield options. The metal shield, optional on S, H and B filtered models, provides shielding from radiated emissions and provides an RF ground for the filter to the panel. This shield is available in two versions; a shield of the filter components (designated by an A as the final digit) and a complete shield (designated by B as the final digit). The A shield covers the filter portion of the module and increases performance of the filter by protecting the components from RFI coupling. This shield allows the use of the C or J extender. The B shield covers the entire power entry module with metal, protecting the filter from RFI coupling, and covering the mounting cut-out to block RFI entering or leaving the equipment. The B shield cannot be used with any extender. A complete metal enclosure is integral to both the high performance L and Z models, and must be specified by a C in the part number's final digit. This option is only available with the L or Z models. Input Voltage Selection Schemes S - "SPMS" Jumper Type 115V 230V Power on/off Hot A G Note 1 Note 1 Note 1 Note 1 B Ground Neutral C Power input Sel. Jumpers D H SMPS Provision for single fusing X - "PRSR" Parallel / Serial Type for Dual Primary Transformer 115V 230V Power on/off Hot "A" Shield G Note 1 Note 2 A B 115V "B" Shield Ground Note 1 Neutral C Note 2 H Provision for single fusing 115V D Transformer primary 194 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Fuseholder Accessories Another feature of the P series power entry module is the versatile fusing arrangement. The fuse holder can hold two 1/4" x 1-1/4" (3AG) or 5 x 20mm (metric) fuses. Single fusing is supported with a conversion clip that shorts one of the two fuse positions, and is designated by an S in the sixth part number digit. A module designated for a single fuse may be reconfigured by the manufacturer or the user to accept two fuses by simply removing the shorting clip. For applications intended for dual fusing, specify a D in the sixth part number digit. GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord PA100: Power interconnect assembly For voltage select models. Designed for use with either filtered or non-filtered units, 6" wire leads Conversion Clip for Single Fuse Applications 3 Power Inlet Filters & Power Entry Modules PA101: Plug only PA102: Pins only for use with PA101 PA105: Same as PA100 but with two wires for units with no voltage selection Interconnection Block Installation of the unfiltered versions of the P series requires wiring of the IEC socket terminals to the optional switch and the switch to the fuse holder. Labor can be eliminated by ordering the module with an interconnection block. This feature, designated by "BX" in the seventh and eighth digits, pre wires the module so that only connection to the equipment must be done during installation. The interconnection block includes a plastic case to prevent access to the internal connections. PA400: J Extender Extends P Series height to fit J panel cutout PA410: L Extender Extends P Series width to fit L panel cutout PA420: C Extender Extends P Series height to fit C panel cutout PA400 Extender for J Series Extender J-Series or others The dimensions of this alternative are the same as the filtered versions. Fuse holder C & L Extenders can not be used with B Shields. L Extender can not be used with shields Optional switch 195 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Optional filter Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Specifications Maximum leakage current each Line to Ground: H & L Models S & Z Models @ 120 VAC 60 Hz: 2 A .25 mA @ 250 VAC 50 Hz: 5 A .50 mA Hipot rating (one minute): Line to Ground: Line to Line: Electrical Schematics H Model LINE LOAD 2250 VDC 1450 VDC Rated Voltage(max.): 250VAC Operating Voltages: Selectable or Fixed 115/230 VAC S Model LINE Operating Frequency: LOAD 50/60 Hz Rated Current: Non-Filtered - 10A Filtered - 3, 6 or 10A L Model Fuseholder: LINE Accepts one or two fuses .25 x 1.25"(not included) or 5 x 20mm (not included) DPST 10,000 operations at 51A max. inrush Switch: LOAD Z Model LINE LOAD Case Styles Front View PM PE PS High Performance Version Only 2.88 2.39 73.15 60.71 2.496 63.4 1.22 30.98 2.29 58.16 1.58 40.13 1.95 49.53 1.22 30.98 196 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Case Styles (continued) Extender Options C Extender - FN260 J Extender - J Series 2.51 63.75 2.72 69.08 Bottom edge Bottom edge Standard Models - Side and Rear View Non-Filtered Filtered 3 2.29 58.16 Power Inlet Filters & Power Entry Modules .225 5.715 2.13 54.10 1.93 49.02 High Performance Models - Side and Rear View PM PE 2.39 60.71 2.17 55.12 3.93 99.82 1.12 28.45 1.23 31.24 4.42 112.27 197 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Case Styles (continued) Shield Options "A" Shield "B" Shield 2.19 55.63 Note: 2.19 55.63 Shields can only be used with filtered models. B shield may not be used with J or C extender Recommended Panel Cutout Cutout PM PE "A" 2.496 63.40 "B" R .06 1.524 1.575 40.00 .135 Note: Mounting Hole Diameter 3.43 For snap-in applications, the "A" sides must have a .020 [.508] radius on the installation side. Dimensions are for front mount applications. Rear mount dimensions should be determined based on customer's application parameters. Snap-in models allow for front mounting only. Not recommended for use in plastic panels. Style Dimension "A" Dimension "B" +.008 - .000 +.008 - .000 No Shield Shielded High Performance Standard High Performance 1.06 [26.92] 1.12 [28.45] 1.12 [28.45] 2.13 [54.10] 2.201 [55.91] PE 1.12 [28.45] 1.12 [28.45] 1.15 [29.21] 2.201 [55.91]* 2.201 [55.91] PS 1.06 [26.92] 1.12 [28.45] - 2.201 [55.91]* - PSC 1.06 [26.92] 1.12 [28.45] - 2.52 [64.01] - PSJ 1.06 [26.92] 1.12 [28.45] - 2.60 [66.04] - PSL 1.12 [28.45] - - 2.201 [55.91]* - PM *For panel thickness of 0.031 - 0.079 [0.787 - 2.01] only. Use 2.213 [56.21] for panel thickness of 0.083 - 0.114 [2.0 - 2.90] 198 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Performance Data Typical Insertion Loss Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Measured in closed 50 Ohm system S Models 3A 6A 10A db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 10 30 Frequency in MHz 0 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz 3 H Models 6A 10A db 100 db 100 db 100 90 90 90 80 80 80 70 70 70 60 60 60 50 50 50 40 40 40 30 30 30 20 20 20 10 10 0 0.1 1 10 30 Frequency in MHz 0 Power Inlet Filters & Power Entry Modules 3A 10 0.1 1 10 30 Frequency in MHz 0 0.1 1 10 30 Frequency in MHz L Models 6A 10A db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 0.1 1 10 30 Frequency in MHz 0.1 1 10 30 Frequency in MHz Z Models 6A 10A db 100 db 100 90 90 80 80 70 70 60 60 50 50 40 40 30 30 20 20 10 0 10 0.01 0.1 1 10 30 Frequency in MHz 0 0.01 199 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Versatile Power Entry Module with Small Footprint (continued) P Series Minimum Insertion Loss Measured in closed 50 Ohm system Differential Mode / Symmetrical (Line to Line) Common Mode / Asymmetrical (Line to Ground) 200 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Connectors SR Series 20ESRMC2 UL Recognized CSA Certified VDE Approved* 20ESRM-3 6ESRMC2 6ESRM-3 SR Series Specifications * Full Line of popular AC receptacles Rated Voltage (max.): * Male and female power line connectors Materials: * Snap-in and flange mount versions * IEC60320-1 C-13 & C14 inlets rated up to 15A * IEC60320-1 C-19 & C-20 inlets rated up to 20A 6 E SR M - P Thermoplastic UL 94V-0 flame rating Prongs: 3 Solid brass, nickel plated Terminals: Brass, tin plated Temperature Rating: For "cold" connections, 65C Power Inlet Filters & Power Entry Modules Ordering Information Insulator: 250 VAC Available Part Numbers Rear Connector Styles 2 - .187 [4.8] spade terminals 3 - .250 [6.3] spade terminals P - PC board pins Male Connector 6ESRM-P 6ESRMC2 6ESRM-3 20ESRMC2 20ESRM-3 Snap-In Flange Mount Fits .063 [1.6] hole Mounting Style C - Snap-In - Flange Front Connector Styles M - Male Type PC Pins Snap-In Flange Mount Female Connector 6ESRFC3 6ESRF-3 Case Styles 6ESRM-P 15A = IEC 60320-1 C-14 20A = IEC 60320-1 C-20 .593* 15.06 .343* 8.71 F - Female .380 9.65 15A = IEC 60320-1 C-13 SR Series Leakage current designation E - Low Leakage (<0.5 mA) Current Rating Indicator 6 = 15A max.* 20 = 20A max.* A B .719 18.26 .360 9.14 1.575 40.00 D .360 9.14 .064 Dia. 1.63 .125 3.17 C .136 Dia. 3.45 .094* 2.39 Pin Layout E .134 Dia. 3.40 1.190* 30.25 Cutout 1.575 40.00 .188 4.78 .094* 2.39 * +.005 -.000 +.127 -.000 *15A versions are VDE approved at 10A, 250VAC max. 20A versions are VDE approved at 16A, 250VAC max. .232 5.9 R .885* 22.48 201 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Power Inlet Connectors (continued) SR Series Case Styles (continued) 6ESRMC2 20ESRMC2 A .1259 3.2 C 1.079 27.4 Cutout .197 R 5.0 .779 19.8 E C Cutout .177 R 4.5 .1259 3.2 A B 6ESRFC3 1.27 32.30 20ESRM-3 .137 Dia. 3.4 .134 Dia. 3.4 1.272 32.26 A Cutout 1.27 32.30 A B .102 2.6 C .157 R 4.0 .975 24.77 E 6ESRM-3 .134 Dia. 3.4 A B G Cutout R C H E Case Dimensions Part No. 6ESRM-P 6ESRMC2 6ESRFC3 6ESRF-3 .134 Dia. 3.4 .134 Dia. 3.4 1.272 32.26 A B .256 C .102 2.6 6.5 6ESRM-3 Cutout R E .134 Dia. 3.4 D .956 24.30 E Cutout .177 R 4.5 .205 5.2 C .956 24.30 6ESRF-3 20ESRMC2 .976 24.77 20ESRM-3 C D E A B 202 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Minimum Depth, Cost-effective Shielded Power Inlet Filter SRB Series SRBP UL Recognized CSA Certified VDE Approved* SRBS8 SRB1 SRB Series SRB2 Specifications * Smallest depth Corcom RFI filter available * Complete shield * Wide range of capacitor values * Attenuates coupled EMI up to 300MHz * Minimal to low leakage current versions are suitable for patient and non-patient contact medical equipment. Ordering Information Hipot rating (one minute): Line to Ground: Line to Line: 15 SRB S 1 - Q Rated Voltage (max.): 250 VAC Operating Frequency: 50/60 Hz Capacitor ID See Chart Omit if none Output Styles 1 - Spade terminals (back) 2 - Spade terminals (bottom) 8 - Wire leads P - PC board pins Mounting Style S - Snap-in X - Slide-in (short edge / horizontal) Y - Slide-in (long edge / vertical) Omit for flange mount SRB Series Current Rating 15A 3 Power Inlet Filters & Power Entry Modules * Full range of mounting and termination options including unique vertical and horizontal orientation slide in mounts eliminate the need for mounting hardware Maximum leakage current each Line to Ground: @120 VAC @250 VAC Capacitor ID / Value 60 Hz 50 Hz Blank / None 2 A 5 A Q / 33 pF 2.1 A 3.65 A R / 100 pF 9.6 A 16.6 A S / 220 pF 19.2 A 33.2 A T / 330 pF 24.0 A 41.5 A W / 470 pF 0.04 mA 0.07 mA X / 1000 pF 0.07 mA 0.13 mA Y / 2200 pF 0.16 mA 0.28 mA Z / 3300 pF 0.24 mA 0.42 mA 2250 VDC 1450 VDC Rated Current: 15A* Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Capacitor Options Capacitor ID Capacitor Value Q R S T W X Y* Z* 33 pF 100 pF 220 pF 330 pF 470 pF 1000 pF 2200 pF 3300 pF *15A versions are tested by Underwriters Laboratories to US and Canadian requirements and are VDE approved at 10A, 250VAC *Not available in SRB8, SRBX or SRBY styles 203 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Minimum Depth, Cost-effective Shielded Power Inlet Filter (continued) SRB Series Available Part Numbers Case Styles SRB1 Flange Mount 15SRB1 15SRB1-Q 15SRB1-R 15SRB1-S 15SRB1-T 15SRB1-W 15SRB1-X 15SRB1-Y 15SRB1-Z 15SRB2 15SRB2-Q 15SRB2-R 15SRB2-S 15SRB2-T 15SRB2-W 15SRB2-X 15SRB2-Y 15SRB2-Z 15SRBP 15SRBP-Q 15SRBP-R 15SRBP-S 15SRBP-T 15SRBP-W 15SRBP-X 15SRBP-Y 15SRBP-Z Snap-In 15SRBS1 15SRBS1-Q 15SRBS1-R 15SRBS1-S 15SRBS1-T 15SRBS1-W 15SRBS1-X 15SRBS1-Y 15SRBS1-Z 15SRBS8 15SRBS8-Q 15SRBS8-R 15SRBS8-S 15SRBS8-T 15SRBS8-W 15SRBS8-X 15SRB8 15SRB8-Q 15SRB8-R 15SRB8-S 15SRB8-T 15SRB8-W 15SRB8-X 15SRBY8 15SRBY8-Q 15SRBY8-R 15SRBY8-S 15SRBY8-T 15SRBY8-W 15SRBY8-X A B SRB2 C B A D E Electrical Schematic LINE D E Slide-In 15SRBX8 15SRBX8-Q 15SRBX8-R 15SRBX8-S 15SRBX8-T 15SRBX8-W 15SRBX8-X C SRBP LOAD C D B A E SRBS1 Accessories C GA400: NEMA 5-15P to IEC 60320-1 C-13 line cord D E A B 204 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Minimum Depth, Cost-effective Shielded Power Inlet Filter (continued) SRB Series Case Styles (continued) SRB8 SRBY8 A .045 Blue Blue Green/Yellow D E Grn/Yel B DE Brown B Brown C Engage panel edge here A max. 0.96 24.39 C SRBS8 3 Case Dimensions Green/Yellow D E B Brown 15SRB1 15SRB2 A 0.96 24.39 max. C 15SRBP 15SRBS1 15SRB8 15SRBS8 SRBX8 15SRBX8 Blue Grn/Yel B DE Brown .045 15SRBY8 A B C D E Power Inlet Filters & Power Entry Modules Part No. Blue A C Engage panel edge here 205 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Minimum Depth, Cost-effective Shielded Power Inlet Filter (continued) SRB Series Recommended Panel Cutouts PC Board Layout 0.075 1.91 SRB1, SRB2, SRBP & SRB8 Front Mount Back Mount .820 20.8 .140 3.56 1.200 30.48 1.575 40.01 0.520 13.21 .900 22.9 .140 3.56 1.200 30.48 1.575 40.01 .12 R. 3.05 Typ. .234 R. 5.94 Typ. Tolerances .005 [0.13] unless otherwise noted .685* 17.40* 0.551 13.99 *.015 [0.38] SRBS R G 0.188 Max. 4.775 0.815 20.70 Tolerance .002 [.050] SRBX8 SRBX Cover .836 .722 21.23 18.34 min. min. Jacket Flange R 0.15 max. 3.81 1.066 27.07 Panel Thickness .039 [1.0] .005 [.127] .005 [.127] SRBY Cover 1.15 1.05 29.21 26.67 min. min. Jacket Flange R 0.15 max. 3.81 .741 18.82 .005 [.127] Panel Thickness .039 [1.0] .005 [.127] 206 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Minimum Depth, Cost-effective Shielded Power Inlet Filter (continued) SRB Series Performance Data Typical Insertion Loss Measured in closed 50 Ohm system Q R S T db 40 db 40 db 40 db 40 35 35 35 35 30 30 30 30 25 25 25 25 20 20 20 20 15 15 15 15 10 10 10 10 5 0 5 1 10 100 300 Frequency in MHz 0 5 1 10 0 100 300 Frequency in MHz 5 1 10 100 300 Frequency in MHz 0 W X Y Z db 40 db 40 db 40 db 40 35 35 35 35 30 30 30 30 25 25 25 20 20 20 15 15 15 15 10 10 10 10 5 0 5 5 1 10 100 300 Frequency in MHz 0 1 10 0 100 300 Frequency in MHz 10 100 300 Frequency in MHz 3 Power Inlet Filters & Power Entry Modules 25 20 1 5 1 10 100 300 Frequency in MHz 0 1 10 100 300 Frequency in MHz Common Mode / Asymmetrical (L-G) Differential Mode / Symmetrical (L-L) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) 207 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 208 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 4. DC Filters -- Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .210 Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .211 DA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .212 DB Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .214 DC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .217 P Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .223 4 DC Filters 209 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Introduction STAY CONNECTED WITH CORCOM PRODUCTS TE Connectivity (TE) is a world leader in EMI-RFI filtering technology. Since 1955, TE has been providing EMI-RFI solutions to leading computer, industrial and telecommunications companies worldwide. Whether you are meeting FCC and international EMC standards on EMI-RFI emissions or developing a newly designed piece of equipment from being disturbed by EMI-RFI in the environment, a power line filter will help your equipment with compliance. This section highlights TE's product offering of DC rated products. Whether the issues involve filtering noise on the data lines or on the power lines, TE can provide the needed solutions for both susceptibility and to help achieve system emissions and immunity compliance. As new technologies in the Telecom-Datacom industry are developed and introduced, TE continues to design and develop new products to address the EMI-RFI filtering issues. TE's design engineers are very actively working with telecom and datacom system engineers to solve EMI-RFI issues. In working with two of the leading North American communications equipment companies, TE engineers solved the EMI-RFI issues present by applying 48 VDC filters at the primary input of the DC power supply. One of the applications was on network routing equipment and required a two-stage 48VDC filter on the input to the DC power supply. TE applied highfrequency attenuating 48VDC filters on the load side of the DC power supplies to solve high-frequency EMI-RFI issues. Cooling Module Ports Trunk Modules TE has provided solutions in both power line filtering and signal line filtering applications for many leading communications companies. As data transmission speeds increase and EMI-RFI issues multiply, TE has developed products to better solve the newer challenges communications companies encounter. Corcom DC power line and signal line filters have been included in: * Network routing equipment * Servers * Modems * Switching equipment * Wireless cabinets * Ethernet hubs * Base stations * Repeater stations * Power supplies for all types of communications equipment TE has developed DC filter products specifically for the communications industry including: * DC power line clean-up filters * Medium and multiple-stage high-performance DC power line filters * High frequency DC power line filters (up to 3GHz) * High current DC power line filters (up to 60A) * Data-transmission signal line filters Corcom DC filters are available in versions that can solve a wide variety of EMI-RFI issues. TE has solved basic EMI-RFI issues with simple cleanup DC filters and has solved more complex EMI-RFI issues with mid-range and multiple-stage high performing DC filters. TE has also solved high-frequency noise problems (up to 3GHz) encountered with high-speed data transmission and switching power supplies. Control Modules Protection Modules Alarm Module 48VDC Line Filters Typical Piece of Communications Equipment Utilizing 48VDC Filters 210 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Selector Chart Compact DC Inlet Connector Yes No Fuse Required Yes No Try The Try The P DA DC DC Series 3-10A Page 223 Series 3-20A Page 212 Series 15-125A Page 217 NEW Series Try The Input DB Series 60A Page 214 Options Current Rating Output Mounting 2-pin Inlet 1/4" Terminal Snap In Panel or Flange Panel Fuse 3, 6, 10A 3-pin Inlet 1/4" Terminal or PC Board Snap In Panel or Flange Panel -- 3, 6, 10, 15A Flange Panel and Rear Mount Compact, Standard, Feedthrough & Hi-Performance Filters and Unfiltered Inlet & Plug available Separately 60A Circuit Breaker and/or High Frequency Performance 15, 30, 60, 100, 125A 4 P DC Filters DA / DAS DB 2-pin High Current Inlet Wire Leads DC Redundant Stud Terminal Block Redundant Stud Bulkhead or or Terminal Block Flange Chassis 211 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact RFI Line Filter with DC Inlet Connection DA Series EN 60 950 UL Recognized CSA Certified TUV Certified DAFP DA Series DAF1 DAS1 Specifications * General purpose line filters for DC applications up to 125VDC. * Compact with a 3-pin inlet connector Hipot rating (one minute): Line to Ground: LIne to Line: 2250 VDC 1450 VDC * Available in 3, 6, 10 and 15A versions Rated Voltage (max): 125 VDC * Flange mount with 1/4" or PCB terminals Rated Current: 3 to 15A * Mates with a standard MOLEX* connector (HCS Series) Operating Ambient Temperature Range (at rated current Ir): -10C to +55C In an ambient temperature (Ta) higher than +55C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 Ordering Information 3 DA F 1 Electrical Schematic Output Styles 1 - .250 [6.3] spade terminals P - PC board mount pins Case Style F - Flange mount S - Snap-in LINE Accessories Red Green/Yellow Black DA Series Current Rating 3, 6, 10 or 15A GA310 - (shown above) Pre-assembled connector housing and terminals with three 36" long 18 gauge wires to mate with DA Series filters Available Part Numbers 3DAF1 3DAS1 3DAFP 6DAF1 6DAS1 6DAFP LOAD 10DAF1 10DAS1 10DAFP 15DAF1 15DAS1 15DAFP MOLEX* connector part numbers: 03-12-1036 Connector housing for DA Series 18-12-1222 Female terminals (3 per connector) 212 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact RFI Line Filter with DC Inlet Connection (continued) DA Series Case Styles Case Dimensions DAF1 Part No. DAF1 C A D E B DAS1 DAS1 DAFP A B C D E Recommended Panel Cutouts DAF A 0.23 max. .820 20.8 D .900 22.9 C .140 Dia. (2) 3.56 1.200 30.48 E 1.575 40.01 1.575 40.01 .12 R 3.05 Back Mount B .551 0.815 20.70 R 0.188 4.78 (4x) DC Filters DAFP 4 DAS "A" .234 R 5.94 Front Mount Rear View .140 Dia. (2) 3.56 1.200 30.48 Performance Data .380 Max. .537 Ref. Minimum Insertion Loss C Measured in closed 50 Ohm system A D E B PC Board Layout Ground 0.104 (3 holes) 2.64 0.520 13.21 Center pin to panel .685.015 17.40.38 0.551 13.99 Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 213 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact RFI High Current DC Inlet Connection DB Series EN 60 950 UL Recognized CSA Certified TUV Certified 60DB8 60DBJ8 DB Series Specifications * Compact connector for high-current DC applications * Reliable performance in a compact assembly * Polarized mating scheme * Easy customer termination of power source * Plug and receptacle available pre-terminated in standard wire lengths * Available filtered or unfiltered Ordering Information Hipot rating (one minute): Line to Ground: LIne to Line: Rated Voltage (max): Filtered Models DBR & DBP 2121 VDC 1768 VDC n/a 1600 VAC 150VDC* 300 VDC 60A (all versions) Rated Current: Operating Ambient Temperature Range (at rated current Ir): -10C to +55C In an ambient temperature (Ta) higher than +55C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/30 60 DB F 8 Output Styles Filtered Models 8 - 6" Wire leads Connector Only L1 - 1' Cable pair L3 - 3' Cable pair L9 - 9' Cable pair Omit for none Type R - Receptacle with clips P - Plug with clips J - Compact filter F - Feedthrough capacitors X - High performance Blank - Standard filter Available Part Numbers Filtered Models 60DB8 60DBF8 Connectors Only 60DBR 60DBP 60DBRL1 60DBPL1 60DBRL3 60DBPL3 60DBPL9 DB Series Current Rating 60A 60DBJ8 60DBX8 WARNING This is not approved for hot swap or current interruption in DC applications. Doing so will result in irreparable damage to contacts. 214 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact RFI High Current DC Inlet Filter (continued) DB Series Electrical Schematics Case Styles DB8 & DBJ8 DBJ8 E D F -VDC (Black) Load Line 2.087 0.375 (ref) 0.591 C RTN (Red) 6.0 Min. A 0.965 1.04 Max. Wire #6 AWG, 300V Extra Flexible IAW UL10198 (2 x) 0.150 Connector Dia. 0.140 Can Dia. B Red (RTN) Label Black (-VDC) DBF8 DB8 & DBF8 -VDC (Black) Line Load C A E RTN (Red) 6.0 Min. 0.375 (ref) 0.277 0.297 B F Label Wire #6 AWG, 300V Extra Flexible IAW UL10198 (2 x) #4-40 Thread (2x) #6-32 Thread (4x) Black (-VDC) DC Filters DBX8 D 4 Red (RTN) 0.423 Line Load -VDC (Black) RTN (Red) DBX8 C A E 6.0 Min. 0.375 (ref) 0.277 0.297 Red (RTN) 0.423 B D F Label Black (-VDC) #6-32 Thread (4x) 60DBPL #4-40 Thread (2x) Wire #6 AWG, 300V Extra Flexible IAW UL10198 (2 x) 60DBRL Available as connector only (shown) or with pre-installed 6AWG 300V Extra Flexible wire 215 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Compact RFI High Current DC Inlet Filter (continued) DB Series Case Styles (continued) DBPL Case Dimensions Part No. A C D E 60DBJ8 B 60DB8 60DBF8 F Black (-VDC) Wire #6 AWG, 300V Extra Flexible IAW UL10198 (2 x) Red (RTN) 60DBX 60DBRL 60DBPL DBRL A B C D E F A C D E B F Performance Data 0.150 Dia. 2x Black (-VDC) Wire #6 AWG, 300V Extra Flexible IAW UL10198 (2 x) Red (RTN) Minimum Insertion Loss Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) Recommended Panel Cutout 0.138 Dia. (2x) 3.50 1.654 42.01 1.370 34.79 R 0.062 (4x) 1.57 1.055 26.79 0.528 13.41 0.493 12.52 Front Mount Panel Cutout Tolerance .005 Rear Mount Panel Cutout Tolerance .005 Differential Mode / Symmetrical (Line to Line) Accessories / Tooling Insertion/Extraction Tool: Crimp per TE spec: Crimp tool: Indenter head: Locator: Connector system locking kit: 0.138 Dia. (2x) 3.50 1.3 33.02 R 0.125 1.654 42.01 (4x) 3.175 0.985 25.01 Contact TE 1643922-1* 114-13206 M22520/23-01 M22520/23-04 M22520/23-11 216 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters for DC Applications DC Series EN 60 950 UL Recognized CSA Certified TUV Certified 60DCF6B DC Series 15DCF10 Specifications * General purpose line filters for DC applications up to 125VDC * Available with or without a circuit breaker Hipot rating (one minute): Line to Ground: LIne to Line: 2250 VDC 1450 VDC * Available with feedthrough capacitors for added high frequency performance Rated Voltage (max): 80 VDC * Available in both flange mound (DCF) and bulkhead mount (DCB) configuration Operating Ambient Temperature Range (at rated current Ir): -10C to +55C In an ambient temperature (Ta) higher than +55C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/30 Rated Current: 15 to 125A 4 Ordering Information 60 DC B 6 B DC Filters Electrical Schematics Options B - Circuit breaker F - Feedthrough capacitors BF - Circuit breaker and feedthrough Standard Performance Note 2 Note 3 LOAD LINE F and BF available only in bulkhead (B) mounting style Note 1 Note 1 Omit for none Input / Output Styles 6 - Redundant stud 10 - Phoenix terminal Note 4 High Frequency Performance (F & BF Styles) Note 2 Mounting Style F = Flange B = Bulkhead and rack LOAD LINE Note 1 Note 3 Required for F or BF options Note 4 DC Series Current Rating 15, 30, 60, 100 or 125A 217 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters for DC Applications (continued) DC Series Available Part Numbers Standard Performance 15DCF6 15DCF10 30DCF6 30DCF10 60DCF6 60DCF10 100DCF6 100DCF10 125DCF6 125DCF10 15DCF6B 15DCF10B 30DCF6B 30DCF10B 60DCF6B 60DCF10B 100DCF6B 100DCF10B 125DCF6B 125DCF10B 15DCB6 15DCB10 30DCB6 30DCB10 60DCB6 60DCB10 100DCB6 100DCB10 125DCB6 125DCB10 15DCB6B 15DCB10B 30DCB6B 30DCB10B 60DCB6B 60DCB10B 100DCB6B 100DCB10B 125DCB6B 125DCB10B High Performance 15DCB10F 15DCB6F 30DCB10F 30DCB6F 60DCB10F 60DCB6F 100DCB10F 100DCB6F 125DCB10F 125DCB6F 15DCB6BF 30DCB6BF 60DCB6BF 100DCB6BF 125DCB6BF 15DCB10BF 30DCB10BF 60DCB10BF 100DCB10BF 125DCB10BF Termination Options Style 6 (15, 30 & 60A) Style 6 (100 & 125A) * Supplied with #10-32 redundant studs * Supplied with 1/4-20 redundant studs * 0.625 [15.88] spacing like polarity * 0.750 [19.05] spacing like polarity * 0.750 [19.05] spacing opposing polarity * 1.00 [25.4] spacing opposing polarity * Torque specification: 27 3 in-lb. * Torque specification: 45 2 in-lb Style 10 (15 & 30A) Style 10 (60A) * PHOENIX CONTACT* part number: VDFK4 * PHOENIX CONTACT* part number: HDFK 16-VP * Accepts 12 AWG stranded wire * Accepts 6 AWG stranded wire * Wire strip length: 0.315 [8.0] * Wire strip length: 0.630 [16.0] * Torque specification: 5.5 - 7.0 in-lb. * Torque specification: 17.7 - 21.2 in-lb. * Ground stud: 8-32 Style 10 (100A) * Ground stud: 10-32 Style 10 (125A) * PHOENIX CONTACT* part number: HDFK 25-VP * PHOENIX CONTACT* part number: HDFK 50-VP * Accepts 4 AWG stranded wire * Accepts 1 AWG stranded wire * Wire strip length: 0.748 [19.0] * Wire strip length: 0.945 [24.0] * Torque specification: 35.4 - 39.9 in-lb. * Torque specification: 35.4 - 39.9 in-lb. * Ground stud: 1/4-20 * Ground stud: 1/4-20 218 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters for DC Applications (continued) DC Series Recommended Panel Cutouts Cutout Dimensions DCB6(F) & DCB10(F) DCB6(F) & DCB10(F) Part No. A Holes: .157 [3.99] Dia. (4) C 15DCB10(F) 30DCB10(F) See case dimensions for spacing 60DCB6(F) B 60DCB10(F) Tolerance: .005 [.13] A 100DCB6(F) 125DCB6(F) 100DCB10(F) 125DCB10(F) DCB6B(F) & DCB10B(F) 15 to 60A 15DCB6B(F) 15DCF6B D B F 15DCB10B(F) 15DCF10B 30DCB6B(F) 30DCF6B 30DCB10B(F) 30DCF10B Tolerance: .005/.13 60DCB10B(F) 60DCF10B E A 60DCF6B(F) 60DCF6B DCB6B(F) & DCB10B(F) 100 to 125A A B C D E F C 1.250 31.75 .625 15.88 .262 6.65 1.557 39.55 Tolerance: .005/.13 A 1.500 x 0.781 38.10 x 19.84 100DCB6B(F) 100DCF6B 125DCB6B(F) 125DCF6B 100DCB10B(F) 100DCF10B B 4 DCB6B(F) & DCB10B(F) 100 to 125A Part No. Holes: .157 [3.99] Dia. (4) See case dimensions for spacing. DC Filters Holes: .157 [3.99] Dia. (4) See case dimensions for spacing. C DCB6B(F) & DCB10B(F) 15 to 60A Part No. C B 15DCB6(F) 30DCB6(F) 125DCB10B(F) 125DCF10B A B C 219 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters for DC Applications (continued) DC Series Case Styles DCB6 & DCB6B DCB10 & DCB10B (60 to 125A) C F A E A E C RTN L I N E B L O A D RTN ON ON -VDC RTN F Tapped insert: 6-32 (4) VDC D VDC RTN OFF OFF L O A D RTN L I N E B D VDC -VDC Tapped insert: 6-32 (4) DCF6 DCF10 (15 & 30A) A E C A E C RTN L I N E D L O A D B RTN RTN -VDC F DCF6B RTN L I N E D -VDC B L O A D -VDC -VDC F DCF10 (60 to 125A) C A E A E C RTN -VDC L I N E D B OFF L O A D D -VDC RTN L O A D ON Tapped insert: 6-32 (4) F C A E RTN RTN -VDC B DCF10B (15 & 30A) A E C F DCB10 & DCB10B (15 to 30A) L O A D -VDC D B L I N E L O A D RTN ON ON RTN OFF OFF L I N E -VDC -VDC F RTN -VDC -VDC D L I N E RTN B Tapped insert: 6-32 (4) Tapped insert: 6-32 (4) F 220 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters for DC Applications (continued) DC Series Case Styles (continued) Case Dimensions (continued) DCF10B (60 TO 125A) C A A E Part No. D B OFF RTN ON Tapped insert: 6-32 (4) F Case Dimensions Part No. 15DCB6(F) 15DCB6B(F) 15DCB10(F) 15DCB10B(F) 15DCF6B(F) 15DCF10 15DCF10B(F) 30DCB6(F) 30DCB6B(F) 30DCB10(F) 30DCB10B(F) 30DCF6 30DCF6B 30DCF10 30DCF10B B C D E F C D E F 4 DC Filters 15DCF6 A 60DCB6B(F) 60DCF6 60DCF6B 60DCF10 60DCF10B 100DCB6(F) 100DCB6B(F) 100DCB10(F) 100DCB10B(F) 100DCF6 100DCF6B 100DCF10 100DCF10B 125DCB6(F) 125DCB6B(F) 125DCB10(F) 125DCB10B(F) 125DCF6 125DCF6B 125DCF10 125DCF10B 60DCB6(F) L O A D VDC RTN VDC L I N E B 221 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide RFI Power Line Filters for DC Applications (continued) DC Series Performance Data (continued) Minimum Insertion Loss Measured in closed 50 Ohm system Standard Performance Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) High Frequency Performance (F & BF Styles) Common Mode / Asymmetrical (Line to Ground) Differential Mode / Symmetrical (Line to Line) 222 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide The CHAMELEON Adaptable Module for DC Applications P Series EN 60 950 UL Recognized CSA Certified TUV Certified P Series Specifications * Full flexibility of design in the most compact package * General purpose designed for DC applications * Mates with a standard MOLEX* connector (HCS Series) which prevents accidental connection to AC Power Ordering Information P S 0 0 0 D D3D (DC Version) Current Rating 3 = 3A 6 = 6A X = 10A Filter Type D = DC version Fuse Options D = Dual fuse S = Single fuse Input Voltage Select 0 = Single voltage Switch Options 0 = No switch Extender Options 0 = None Rated Voltage (max): 80 VDC Rated Current: 3 to 10A Fuseholder*: Terminals: 2250 VDC 1450 VDC .25 x 1.25" or 5 x 20 mm .187 x .032 [4.8 x .81] terminal tabs 4 Operating Ambient Temperature Range (at rated current Ir): -10C to +40C In an ambient temperature (Ta) higher than +40C the maximum operating current (Io) is calculated as follows: Io = Ir (85-Ta)/45 DC Filters Shield Options D = Complete Shield Hipot rating (one minute): Line to Ground: LIne to Line: Electrical Schematic LINE LOAD Available Part Numbers PE000DD3D PE000DD6D PE000DDXD PE000SD3D PE000SD6D PE000SDXD Mounting Style E = Mounting ears S = Snap-in PS000DD3D PS000DD6D PS000DDXD PS000SD3D PS000SD6D PS000SDXD 223 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide The CHAMELEON Adaptable Module for DC Applications (continued) P Series Case Styles Case Dimensions PE Part No. B C D E F PE C A PS Recommended Panel Cutouts F A .06 R Max. 1.52 B .07 1.78 min. Radius Ground connection PS E External Edge (1) .020 R Min. .508 C D B Note: The external edges (installation side) on the "D" sides of the cutout should have a minimum .020" radius. For optimal retention against extraction, the corresponding inner edge should be sharp, without paint or coatings. Edge coatings, including anodization are also discouraged for good shield contact. A Performance Data Accessories Minimum Insertion Loss Red Black Measured in closed 50 Ohm system Common Mode / Asymmetrical (Line to Ground) GA210 - (shown above) Pre-assembled connector housing with two 36" long 18 gauge wires to mate with P Series DC filters Differential Mode / Symmetrical (Line to Line) MOLEX Part Numbers: 03-12-1026 DC Connector housing for P Series 18-12-1222 Female terminals (2 per connector) 224 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 5. Feedthrough Filters and Capacitors -- Table of Contents Feedthrough Application Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . .225 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .226 FFA Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .228 FFD Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .231 AFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .234 DFC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .237 Feedthrough Application Selector Chart Type of Feedthrough Filter Capacitor Application Application DC AC DC Try The Try The Try The Try The FFA FFD AFC DFC Series Feedthrough AC Filters Page 228 Series Feedthrough DC Filters Page 231 Series Feedthrough AC Capacitors Page 234 Series Feedthrough DC Capacitors Page 237 5 Feedthrough Filters and Capacitors AC 225 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Introduction - Corcom Feedthrough Filters and Capacitors Installation, Background and Safety Applications Feedthrough capacitors and filters are designed for through-bulkhead mounting for offering high frequency filtering in line-to-ground applications. They should be mounted through a metal bulkhead or chassis. The bulkhead mounting surface should be clean and unpainted to offer a low impedance path from the capacitor or filter to the equipment chassis. Poor earth bonding will limit the available performance of the product and could compromise safety. Offers reliability and performance in high frequency applications such as: * Servers * Base stations * Routers * Main power supplies * Telecom systems / racks * MRI rooms * High power microwave lines Conductive paint finishes should be avoided as they do not usually provide adequate conductivity. Two wrenches (or spanners) should be used when making electrical connections to the terminals and maximum tightening torque figures quoted should be observed. * Military vehicles and equipment Relevant safety standards have been adhered to in the design and manufacture of these products. However, all capacitors will store charge after power has been removed and must be treated with respect as this can be lethal when the voltage and charge are high enough. The filters and capacitors contained within this catalog do not contain internal discharge resistors. It is therefore recommended that they are fitted with external discharge resistors to discharge the capacitors after the power has been removed. Where necessary, terminals should be enclosed by the user to prevent any danger of electric shock or accidental shorting. In all cases, capacitors and filters should always be shorted to earth prior to touching to ensure they are fully discharged. * High frequency welding equipment * High current switch mode power supplies * Power amplifier and generators * Industrial controls * Screened rooms * Secure communications * Computer facilities Key Features * Designed to meet EN133200 and EN132400 safety requirements * Custom designs available where special packaging, mounting, terminations, or multiple lines are required. * RoHS compliant The user should ensure he/she is familiar with restrictions on capacitance value, earth leakage current, test voltage, and safety labeling requirements, which may be applicable to his/her particular installation. In particular, safety standards IEC950 and EN60950, which most electrical equipment needs to comply with, contain a number of specific requirements for capacitors, which may be applicable. 226 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Introduction - Corcom Feedthrough Filters and Capacitors Figure 1: Feedthrough Filters Performance FEEDTHROUGH CAPACITOR PERFORMANCE * Normal two-terminal capacitors resonate with their lead inductance in the region of 1 to 10MHz * Feedthrough capacitors have no major resonance as they have no lead inductance * Performance continues to increase with frequency * Feedthrough capacitors are essential for good high frequency performance 10 20 Two-Terminal Capacitor 1 IMPEDANCE () * This limits their use as suppression components above a few MHz 0 10 30 40 0.1 50 Feedthrough Actual 60 Theoretical 0.01 70 80 0.001 10K * Feedthrough filters incorporate feedthrough capacitors for the same benefits 90 100K 1M 10M INSERTION LOSS IN 50 OHM SYSTEM (dB) Feedthrough Capacitor Performance 100 100M Frequency (Hz) * As an example, the graph in Figure 1 compares the performance of a 1F feedthrough capacitor with a 1F two-terminal capacitor 5 Feedthrough Filters and Capacitors 227 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide AC Feedthrough Filters - Class Y2 FFA Series Component Recognized by UL to US and Canadian Requirements FFA Series Specifications * AC feedthrough filters Rated Voltage (max): 250 VAC * Current Ratings from 10 to 300A Operating Frequency: 50/60 Hz * Designed to meet the very stringent safety requirements of EN133200 class Y2 including the 5000V pulse test Rated Current: 10 to 300A Test Voltage (two seconds): 5000 VDC Capacitor Class (EN133200): Designed to meet Y2 * Custom versions available Pulse Test (EN133200): Ordering Information Insulation Resistance (within 1 minute): For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s 10 FFA6 - BA 5000V Peak Operating Ambient Temperature Range (at rated current Ir): Filter ID See Table 10 to 100A: -40C to +60C 200A: -40C to +50C 250 & 300A: -40C to +40C FFA Series Screw Terminals Category Temperature Range: Current Rating (in A) 10-100A: For temperature, = R (85-)/25 200A: For temperature, = R (85-)/35 Filter Options / Specifications Max. DC Leakage Filter Inductance Current Resistance ID Value (nF) (nH) (mA)* (m) Max. BA 2 x 4.7 70 0.9 6 CA 2 x 10 70 1.9 4 CE 2 x 10 140 1.9 7 DG 2 x 22 170 4.2 4 DH 2 x 22 180 4.2 4 GB 2 x 47 80 8.9 3 GJ 2 x 47 210 8.9 9 HC 2 x 100 90 19 2 HD 2 x 100 120 19 1 HF 2 x 100 160 19 <1 HN 2 x 100 250 19 6 JK 2 x 150 240 29 3 NP 2 x 470 330** 89 <2 PP 2 x 1000 330 188 <2 -40C to +85C Current Derating Above Ambient: 250 & 300A: For temp., = R (85-)/45 Climatic Category: 40/85/21 MTBF: > 5 million hours typical Insulating Materials Flammability Rating: Case & Terminal Material: UL94V-0 Nickel Plated Brass Electrical Schematic 228 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide AC Feedthrough Filters - Class Y2 (continued) FFA Series Case Style Case Dimensions Resin Fill T2 (Mounting thread) T1 (Terminal thread) Part No. 10FFA6-BA B D C E F A 16FFA6-CA 32FFA6-CA 63FFA6-GB T1 - Terminal Thread Part No. Thread Torque max. in.lb. 100FFA6-HC 200FFA6-HD 10FFA6-BA/CE/CJ 16FFA6-CA/DG/HN 32FFA6-CA/DH/HN 63FFA6-GB/JK/NP M3 4 M4 11 M6 22 100FFA6-HC/NP/PP M8 44 200FFA6-HD/NP/PP M10 70 250FFA6-HF/NP/PP M12 97 16FFA6-DG 32FFA6-DH 300FFA6-HF/NP/PP M16 177 63FFA6-JK Thread Torque max. in.lb. T2 - Mounting Thread Part No. 63FFA6-JK 100FFA6-HC 10FFA6-CE 100FFA6-NP 200FFA6-NP M12 x 1 35 250FFA6-NP 300FFA6-HN M16 x 1 62 10FFA6-GJ 89 16FFA6-HN 32FFA6-HN M20 x 1 63FFA6-NP 100FFA6-NP 200FFA6-HD 63FFA6-NP 100FFA6-PP 200FFA6-NP/PP 250FFA6-HF/NP/PP 300FFA6-HF/NP/PP M24 x 1 124 100FFA6-PP M27 x 1.5 M32 x 1.5 142 200FFA6-PP 212 250FFA6-PP 300FFA6-PP B C D E F 5 Feedthrough Filters and Capacitors 10FFA6-BA/CE/CJ 16FFA6-CA 32FFA6-CA 16FFA6-DG/HN 32FFA6-DH/HN 63FFA6-GB 300FFA6-HF A 229 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide AC Feedthrough Filters - Class Y2 (continued) FFA Series Available Part Numbers Standard Performance 10FFA6-BA 16FFA6-CA 32FFA6-CA 63FFA6-GB 100FFA6-HC 200FFA6-HD 250FFA6-HF 300FFA6-HF High Performance 10FFA6-CE 16FFA6-DG 32FFA6-DH 63FFA6-JK 100FFA6-NP 200FFA6-NP 250FFA6-NP 300FFA6-NP Extended Performance 10FFA6-GJ 16FFA6-HN 32FFA6-HN 63FFA6-NP 100FFA6-PP 200FFA6-PP 250FFA6-PP 300FFA6-PP Performance Data Typical Insertion Loss -- Line to Ground in 50 Ohm circuit 230 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide DC Feedthrough Filters - Class Y4 FFD Series Component Recognized by UL to US and Canadian Requirements FFD Series Specifications * DC feedthrough filters Rated Voltage (max): * Current ratings from 10 to 200A Rated Current: * Designed to meet the very stringent safety requirements of EN133200 class Y4 including the 2500V pulse test 130 VDC 10 to 200A Test Voltage (two seconds): 2500 VDC Capacitor Class (EN133200): Designed to meet Y4 Pulse Test (EN133200): 2500V Peak Insulation Resistance (within 1 minute): For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s * Custom versions available Ordering Information Operating Ambient Temperature Range (at rated current Ir): 10 FFD6 - CA 10 to 100A: -40C to +60C 200A: -40C to +50C Filter ID See Table Category Temperature Range: FFD Series Screw Terminals -40C to +85C 10-100A: For temperature, = R (85-)/25 200A: For temperature, = R (85-)/35 Current Rating (in A) Climatic Category: 40/85/21 Filter ID CA HB HE NC ND NH PK RP Value (nF) 2 x 10 2 x 100 2 x 100 2 x 470 2 x 470 2 x 470 2 x 1000 2 x 4700 Inductance (nH) 70 80 140 90 120 180 240 330 > 5 million hours typical Insulating Materials Flammability Rating: DC Resistance (m) Max. 6 3 8 2 1 3 2 2 Feedthrough Filters and Capacitors MTBF: Filter Options / Specifications 5 Current Derating Above Ambient: Case & Terminal Material: UL94V-0 Nickel Plated Brass Electrical Schematic 231 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide DC Feedthrough Filters - Class Y4 (continued) FFD Series Case Style Case Dimensions Resin Fill T2 (Mounting thread) T1 (Terminal thread) Part No. 10FFD6-CA B D C E F A 16FFD6-CA 32FFD6-CA 63FFD6-HB T1 - Terminal Thread Part No. Thread Torque max. in.lb. 100FFD6-NC 200FFD6-ND 10FFD6-CA/HE 16FFD6-CA/HE 32FFD6-CA/HE 63FFD6-HB/NH M3 4 M4 11 10FFD6-HE M6 22 100FFD6-NC/PK M8 44 16FFD6-HE 32FFD6-HE 200FFD6-ND/RP M10 70 63FFD6-NH 100FFD6-PK T2 - Mounting Thread Part No. Thread Torque max. in.lb. 10FFD6-CA/HE 16FFD6-CA/HE 32FFD6-CA/HE M12 x 1 35 63FFD6-HB/NH M20 x 1 89 100FFD6-NC/PK M24 x 1 124 200FFD6-ND/RP M27 x 1.5 142 200FFD6-RP A B C D E F 232 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide DC Feedthrough Filters - Class Y4 (continued) FFD Series Available Part Numbers Standard Performance 10FFD6-CA 16FFD6-CA 32FFD6-CA 63FFD6-HB 100FFD6-NC 200FFD6-ND High Performance 10FFD6-HE 16FFD6-HE 32FFD6-HE 63FFD6-NH 100FFD6-PK 200FFD6-RP Performance Data Typical Insertion Loss -- Line to Ground in 50 Ohm circuit 5 Feedthrough Filters and Capacitors 233 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide AC Feedthrough Capacitors - Class Y2 AFC Series Component Recognized by UL to US and Canadian Requirements AFC Series Specifications * AC feedthrough capacitors Rated Voltage (max): 250 VAC * Current ratings from 10 to 300A Operating Frequency: 50/60 Hz * Designed to meet the very stringent safety requirements of EN132400 class Y2 including the 5000V pulse test Rated Current: 10 to 300A Test Voltage (two seconds): 5000 VDC Capacitor Class (EN132400): Designed to meet Y2 * Custom versions available Pulse Test (EN132400): Ordering Information Insulation Resistance (within 1 minute): For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s 10 AFC6 - A 5000V Peak Operating Ambient Temperature Range (at rated current Ir): 10 to 200A: -40C to +60C 250 & 300A: -40C to +40C Filter ID See Table Category Temperature Range: AFC Series Screw Terminals Current Derating Above Ambient: 10-200A: For temperature, = R (85-)/25 250 & 300A: For temp., = R (85-)/45 Current Rating (in A) Climatic Category: Filter Options / Specifications 40/85/21 MTBF: Filter ID A B C F G H K N P Value (nF) 2.2 4.7 10 33 47 100 220 470 1000 -40C to +85C Max. Leakage Current (mA)* 0.21 0.44 0.94 3.1 4.4 9.4 21 44 94 > 10 million hours typical Insulating Materials Flammability Rating: Case & Terminal Material: UL94V-0 Nickel Plated Brass 234 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide AC Feedthrough Capacitors - Class Y2 (continued) AFC Series Case Style Case Dimensions Resin Fill T2 (Mounting thread) T1 (Terminal thread) Part No. 10AFC6-A 10AFC6-B B D C E F 16AFC6-B 16AFC6-C A 16AFC6-G T1 - Terminal Thread 16AFC6-H Thread Torque max. in.lb. 10AFC6-A/B M3 4 16AFC6-B/C/G/H 20AFC6-B 32AFC6-B/C/F/G/H M4 11 32AFC6-B 32AFC6-C 63AFC6-C/G/H M6 22 32AFC6-F 32AFC6-G 100AFC6-G/H/K/N M8 44 200AFC6-H/K/N/P M10 71 250AFC6-H/K/N/P M12 97 300AFC6-H/K/N/P M16 177 Part No. 20AFC6-B 32AFC6-H 63AFC6-C 63AFC6-G 63AFC6-H 100AFC6-G 100AFC6-H T2 - Mounting Thread Thread Torque max. in.lb. 100AFC6-K 10AFC6-A/B M10 x 1 27 200AFC6-H 200AFC6-K M12 x 1 35 16AFC6-B/C/G 20AFC6-B 32AFC6-B/C/G/F 16AFC6-H 32AFC6-H 63AFC6-C/G/H 200AFC6-N 200AFC6-P 250AFC6-H 250AFC6-K M16 x 1 62 100AFC6-G/H M20 x 1 89 300AFC6-H 300AFC6-K 100AFC6-K/N 200AFC6-H/K M24 x 1 124 300AFC6-N 300AFC6-P 200AFC6-N/P M27 x 1.5 142 250AFC6-N 250AFC6-P B C D E F 5 Feedthrough Filters and Capacitors Part No. A 235 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide AC Feedthrough Capacitors - Class Y2 (continued) AFC Series Available Part Numbers 10AFC6-A 10AFC6-B 16AFC6-B 16AFC6-C 16AFC6-G 16AFC6-H 20AFC6-B 32AFC6-B 32AFC6-C 32AFC6-F 32AFC6-G 32AFC6-H 63AFC6-C 63AFC6-G 63AFC6-H 100AFC6-H 100AFC6-H 100AFC6-K 100AFC6-N 200AFC6-H 200AFC6-K 200AFC6-N 200AFC6-P 250AFC6-H 250AFC6-K 250AFC6-N 250AFC6-P 300AFC6-H 300AFC6-K 300AFC6-N 300AFC6-P Performance Data Typical Insertion Loss -- Line to Ground in 50 Ohm circuit 236 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide DC Feedthrough Capacitors - Class Y4 DFC Series Component Recognized by UL to US and Canadian Requirements DFC Series Specifications * DC feedthrough capacitors Rated Voltage (max): * Current ratings from 10 to 300A Rated Current: * Designed to meet the very stringent safety requirements of EN132400 class Y4 including the 2500V pulse test 130 VDC 10 to 300A Test Voltage (two seconds): 2500 VDC Capacitor Class (EN132400): Designed to meet Y4 Pulse Test (EN132400): 2500V Peak Insulation Resistance (within 1 minute): For C < 0.33F, R> 15000M For C > 0.33F, RC(M*F)>5000s * Custom versions available Operating Ambient Temperature Range (at rated current Ir): Ordering Information 10 to 200A: -40C to +60C 250 & 300A: -40C to +40C 10 DFC6 - C Filter ID See Table DFC Series Screw Terminals -40C to +85C 10-200A: For temperature, = R (85-)/25 250 & 300A: For temp., = R (85-)/45 Climatic Category: 40/85/21 MTBF: > 10 million hours typical Insulating Materials Flammability Rating: Filter Options / Specifications Filter ID C G H N P Q R T 5 Current Derating Above Ambient: Feedthrough Filters and Capacitors Current Rating (in A) Category Temperature Range: Case & Terminal Material: UL94V-0 Nickel Plated Brass Value (nF) 10 47 100 470 1000 3300 4700 8000 237 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide DC Feedthrough Capacitors - Class Y4 (continued) DFC Series Case Style Case Dimensions Resin Fill T2 (Mounting thread) A B C D E F 63DFC6-C 63DFC6-G 63DFC6-H 63DFC6-N 100DFC6-G 100DFC6-H 100DFC6-N T1 (Terminal thread) Part No. 10DFC6-C B D C E F 16DFC6-C A 16DFC6-G 16DFC6-H T1 - Terminal Thread Thread Torque max. in.lb. 16DFC6-N M3 4 32DFC6-C M4 11 M6 22 32DFC6-G 32DFC6-H 100FDC6-G/H/N/P M8 44 200DFC6-H/N/P/R M10 71 250DFC6-P/Q/T M12 97 300DFC6-P/Q/T M16 177 Part No. 10DFC6-C 16DFC6-C/G/H/N 32DFC6-C/G/H/N 63DFC6-C/G/H/N T2 - Mounting Thread 32DFC6-N Part No. Thread Torque max. in.lb. 10DFC6-C M10 x 1 27 100DFC6-P 16DFC6-C/G/H 32DFC6-C/G/H M12 x 1 35 200DFC6-H 200DFC6-N 63DFC6-C/G/H M16 x 1 62 200DFC6-P M20 x 1 89 16DFC6-N 32DFC6-N 63DFC6-N 100DFC6-G/H/N 100DFC6-P 200DFC6-H/N/P 200FFC6-R 200DFC6-R 250DFC6-P 300DFC6-P M24 x 1 124 M27 x 1.5 142 250DFC6-Q 300DFC6-Q 250DFC6-T 300DFC6-T 238 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide DC Feedthrough Capacitors - Class Y4 (continued) DFC Series Available Part Numbers 10DFC6-C 16DFC6-C 16DFC6-G 16DFC6-H 16DFC6-N 32DFC6-C 32DFC6-G 32DFC6-H 32DFC6-N 63DFC6-C 63DFC6-G 63DFC6-H 63DFC6-N 100DFC6-G 100DFC6-H 100DFC6-N 100DFC6-P 200DFC6-H 200DFC6-N 200DFC6-P 200DFC6-R 250DFC6-P 250DFC6-Q 250DFC6-T 300DFC6-P 300DFC6-Q 300DFC6-T Performance Data Typical Insertion Loss -- Line to Ground in 50 Ohm circuit 5 Feedthrough Filters and Capacitors 239 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 240 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide 6. Signal Line Products -- Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .242 SignalSentry Filtered Modular Jacks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .243 SignalSentry Product Part Number Matrix / Ordering Information . . . .244 SignalSentry Product Selector Chart . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .245 L Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .247 L - Ganged Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .248 LC Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .249 LCT Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 N Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .251 X Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252 Z Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .253 Model Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255 L, LC, LCT and X Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . .255 N and Z Series RJ Jack Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .257 6 Signal Line Products 241 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Introduction Corcom brand SignalSentry filtered modular jack series product combines different levels of filtering with RJ45 and RJ11 modular jacks to solve signal line noise problems and crosstalk. Corcom brand SignalSentry filtered modular jack series product has expanded into 80 different products for filtering the signal line, including inductor and capacitor, shielded, ganged, low profile and surface mountable versions. Designs not only save valuable panel space, but also place the filtering elements where they can be most effective in eliminating RFI. The L and N series RJ11 and RJ45 jacks offer filtering with inductance and optional shielding, while the LC and LCT series combine inductance with 82pF or 820pF capacitors. The X and Z series complete the offering with unfiltered versions of our standard profile and low profile jacks. Use the selector chart to combine your filtering performance with the RJ11 or RJ45 jacks. Mechanical dimensions are listed following the series information. For the latest information and additional technical articles, find Corcom products on the Internet at www.corcom.com. 242 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide SignalSentry Filtered Modular Jacks Corcom brand SignalSentry filtered modular jacks are a space saving and cost-effective solution to RFI problems on signal lines. Its inductive and optional capacitive elements effectively strip common-mode noise from the incoming signal, and at the same time limit the signal line's ability to radiate emissions like an antenna. The SignalSentry filtered modular jack series has expanded into 80 different products for filtering the signal line, including inductor and capacitor, shielded, ganged, low profile and surface mountable versions. Filtered RJ jacks provide interference suppression at the optimal location by integrating the filtering into the RJ jack itself. Our new ganged jacks are the only RJ11 filtered ganged jacks available in the market. SignalSentry filtered modular jack products are useful for any electronic equipment that sends or receives data on unshielded twisted pair or other multi-conductor cabling systems. Modems, PBX's, LAN, ISDN, and local I/O interfaces that use RJ connectors are all candidates. Jack design and component selection compatible with equipment registered under FCC part 68. UL Recognized CSA Certified Applications A fax/modem board was being certified for FCC Class B emissions at an independent test laboratory. The board caused every computer it was tested in to exceed the radiated limits above 30 MHz, at multiples of each microprocessor's clock frequency, on the telephone line. The test lab replaced the modem's unfiltered RJ11 jack with a Corcom RJ11-4L-B filtered modular jack out of their sample kit, and the board/computer combinations passed with 4 dB margin worst case. An RISC workstation designed to operate in a twisted-pair Local Area Network required two DIP package inductors and 12 chip capacitors to meet FCC radiated emissions limits. All 14 discrete components were eliminated by replacing the two RJ45 connectors with two Corcom RJ45-8LC1-B shielded and filtered jacks, and the margin of compliance actually improved. A secure telephone set failed hardened application testing at a government facility, due to intelligible emanations radiated from the coiled handset cord. The unit passed after the handset connector in the desk set was replaced by a Corcom RJH-4L-B filtered handset jack. 6 Signal Line Products A medical manufacturer was designing a heart monitor which would transfer data over a signal line to the nurses' station so they could monitor patients. When the doctors used their modems, the data coming from the monitor became distorted. This occurred due to the close proximity of the modem card and monitor communication card placed next to each other. A Corcom low profile RJ45-8N3-B modular jack was designed in to filter out the unwanted noise. 243 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide SignalSentry Part Number Matrix / Ordering Information WHAT TYPE OF CONNECTOR DO YOU NEED? Handset jack four pin connector RJ11 six pin connector RJ45 eight pin connector RJ11 RJH RJ11 RJ45 HOW MANY TERMINALS WILL BE LOADED? 4 on RJH 2, 4 or 6 on RJ11 6 or 8 on RJ45 4 WHAT LEVEL OF FILTERING PERFORMANCE DO YOU NEED? No filter, standard profile Inductor (block or sleeve), standard profile Inductor plus capacitors with shield Inductor, 82 pF cap. and shield Inductor (block or sleeve), low profile No filter, low profile DO YOU WANT A SHIELDED JACK? X models L models LC models LCT model N models Z models L WHAT TYPE OF GROUND? 1Panel and board ground (spring fingers on panel interface) 1Board ground pins only 2Panel, board and cable ground (low profile versions) 2Board ground and cable ground (low profile versions) 1 2 3 4 1 WHAT TYPE OF INDUCTORS DO YOU NEED? Sleeve -- Average performance Block -- Higher performance S B B RJ11 Model Contact Loading Program RJ45 Model Contact Loading Program 1 2 3 4 5 6 Jack Designation RJ11 - 2 RJ11 - 4 RJ11 - 6 Lead Frame Position 2 3 4 5 6 1 1 2 3 4 5 6 7 8 Jack Designation RJ45 - 6 RJ45 - 8 1 2 Lead Frame Position 3 4 5 6 7 8 244 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide SignalSentry Selector Chart Yes Filtered No Try The X Series Standard Profile Modular Jack Page 252 Level of Filtering Z Inductor and Capacitor Series Low Profile Modular Jack Page 253 Inductor Only Ganged Jacks Try The LC Yes No Series 820pF Modular Jack Page 249 Try The Try The LCT L (Ganged) L Series 82pF Modular Jack Page 250 Series Standard Profile Modular Jack Page 248 Series Standard Profile Modular Jack Page 247 6 Signal Line Products N Series Low Profile Modular Jack Page 251 245 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 246 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Inductive Filtering Modular RJ Jacks L Series UL Recognized CSA Certified RJ11 RJ11 with Block Filter RJ45 with Sleeve Filter RJ45 L Series Specifications * Inductive filtering in standard RJ11, RJ45, or handset jacks. Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. * Available with standard ferrite sleeve inductors or higher performance ferrite blocks * Available unshielded or shielded with board grounded shield or spring fingered panel ground interface Available Part Numbers Ferrites: Type: Sleeves: Block: High resistivity, nickel zinc ceramic Single-aperture cylinders Multi-aperture rectangular prism Shield Material: Tin-plated copper alloy Housing Material: Glass-filled polyester (UL94V-0) Dielectric Withstanding Voltage: Line to Line and Line to Ground: Printed Circuit Board Retention: Before soldering: After soldering: 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum Typical Impedance in Ohms 6 150 140 130 120 110 Impedance in Ohms 100 90 Signal Line Products Inductor Filter RJH-4L-B RJ45-6L-S RJ11-2L-S RJ45-6L-B RJ11-2L-B RJ45-8L-S RJ11-4L-S RJ45-8L-B RJ11-4L-B RJ11-6L-S RJ11-6L-B Inductor Filter and Shield RJ11-2L2-B RJ45-6L1-S RJ11-4L1-S RJ45-6L1-B RJ11-4L1-B RJ45-6L2-S RJ11-4L2-S RJ45-6L2-B RJ11-4L2-B RJ45-8L1-S RJ11-6L1-S RJ45-8L1-B RJ11-6L1-B RJ45-8L2-S RJ11-6L2-S RJ45-8L2-B RJ11-6L2-B 80 70 60 50 40 30 20 10 0 1 25 100 200 500 Frequency in MHz Ferrite block Ferrite sleeve Shield 2 Shield 1 Model dimensions and PC board layout on pages 255-259 247 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Inductive Filtering Ganged Modular RJ Jacks L - Ganged Series 4RJ11 UL Recognized CSA Certified 6RJ11 2RJ11 with Block Filter L - Ganged Series Specifications * Ganged version of our L Series filtered jacks Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. * Available in RJ11 models with block inductors * Available in gangs of 2, 4 or 6 * Retrofits existing unfiltered ganged jack footprints Ferrites: Type: Block: Dimensions and PC Board Layout Housing Material: .050 1.27 A .470 11.94 Glass-filled polyester (UL94V-0) Dielectric Withstanding Voltage: Line to Line and Line to Ground: Printed Circuit Board Retention: Before soldering: After soldering: B C .325 8.25 High resistivity, nickel zinc ceramic Multi-aperture rectangular prism .100 2.54 .050 [1.27] 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum + .008 .030 - .003 Dia. .250 .350 [8.89] [6.35] .128 + .003 Dia. D .810 20.57 .590 14.99.040 1.02 Available Part Numbers 2RJ11-6L-B 6RJ11-6L-B 4RJ11-6L-B Typical Impedance in Ohms 150 .195 140 Ports 130 .165 4.19 120 A B C D 4 6 2 110 100 Impedance in Ohms .410 10.41 90 80 70 60 50 40 30 20 10 0 1 25 100 200 500 Frequency in MHz 248 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Filtered Modular Jacks with Enhanced Performance LC Series UL Recognized CSA Certified Shield 2 RJ11 Shield 1 RJ11 Shield 2 RJ45 Shield 1 RJ45 LC Series Specifications * Chip capacitors provide enhanced filtering performance on each line Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. * Available with block or sleeve inductance * Available with board grounded shield or spring fingered panel ground interface Capacitors: Type: Standard Value: Standard Tolerance: Performance Data Typical Insertion Loss Ferrites: Type: Sleeves: Block: Shield Material: High resistivity, nickel zinc ceramic Single-aperture cylinders Multi-aperture rectangular prism Housing Material: Monolithic ceramic chip 820 pF 20% Tin-plated copper alloy Glass-filled polyester (UL94V-0) Dielectric Withstanding Voltage: Line to Line and Line to Ground: Printed Circuit Board Retention: Before soldering: After soldering: 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum 6 Model dimensions and PC board layout on pages 255-259 Available Part Numbers RJ11-2LC1-S RJ11-2LC1-B RJ11-2LC2-S RJ11-2LC2-B RJ11-4LC1-S RJ11-4LC1-B RJ11-4LC2-S RJ11-4LC2-B RJ11-6LC1-S RJ11-6LC1-B RJ11-6LC2-S RJ11-6LC2-B RJ45-6LC1-S RJ45-6LC1-B RJ45-6LC2-S RJ45-6LC2-B RJ45-8LC1-S RJ45-8LC1-B RJ45-8LC2-S RJ45-8LC2-B Signal Line Products 249 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Low Capacitance Modular RJ Jacks LCT Series UL Recognized CSA Certified Shield 2 RJ11 Shield 1 RJ11 Shield 2 RJ45 Shield 1 RJ45 LCT Series Specifications * Low capacitance model for improved performance. Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. * Particularly suited for ethernet applications * Available with block or sleeve inductance * Available with board grounded shield or spring fingered panel ground interface Capacitors: Type: Standard Value: Standard Tolerance: Performance Data Typical Insertion Loss Ferrites: Type: Sleeves: Block: Shield Material: High resistivity, nickel zinc ceramic Single-aperture cylinders Multi-aperture rectangular prism Housing Material: Monolithic ceramic chip 82 pF 20% Tin-plated copper alloy Glass-filled polyester (UL94V-0) Dielectric Withstanding Voltage: Line to Line and Line to Ground: Printed Circuit Board Retention: Before soldering: After soldering: 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum Available Part Numbers RJ11-6LCT1-S RJ11-6LCT1-B RJ11-6LCT2-S RJ11-6LCT2-B RJ45-8LCT1-S RJ45-8LCT1-B RJ45-8LCT2-S RJ45-8LCT2-B Model dimensions and PC board layout on pages 255-259 250 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Low Profile Filtered Modular Jacks N Series UL Recognized CSA Certified Shield 3 RJ11 Shield 4 RJ45 N Series Specifications * Low profile SignalSentry filtered jack * Available unshielded or shielded with board grounded shield or spring fingered panel ground interface Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. Typical Impedance in Ohms Ferrites: Type: Sleeves: Block: * Available with sleeve or block inductors High resistivity, nickel zinc ceramic Single-aperture cylinders Multi-aperture rectangular prism Impedance in Ohms Shield Material: 100 90 80 70 60 50 40 30 20 10 0 Housing Material: Tin-plated copper alloy Black glass-filled polyamide (STANYL TE250F3) Dielectric Withstanding Voltage: Line to Line and Line to Ground: Printed Circuit Board Retention: Before soldering: After soldering: 1 25 100 200 500 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum 1000 Frequency in MHz Ferrite block 6 Ferrite sleeve Available Part Numbers RJ11-6N-B RJ11-6N4-B Signal Line Products RJ11-6N3-B RJ45-8N-B RJ45-8N-S RJ45-8N3-B RJ45-8N3-S RJ45-8N4-B RJ45-8N4-S Unshielded Ferrite Block Model dimensions and PC board layout on pages 255-259 251 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Unfiltered Modular Jacks X Series UL Recognized CSA Certified RJ45 RJ11 X Series Specifications * Unfiltered standard jack Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. * RJ11 or RJ45 * 2, 4, 6 or 8 loaded contacts * Available unshielded or shielded with board grounded shield or spring fingered panel ground interface Shield Material: Housing Material: Tin-plated copper alloy Glass-filled polyester (UL94V-0) Dielectric Withstanding Voltage: Line to Line and Line to Ground: Printed Circuit Board Retention: Before soldering: After soldering: Shield 1 Shield 2 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum Available Part Numbers RJ11-2X RJ11-4X RJ11-6X RJ45-6X RJ45-8X RJ45-8X1 RJ45-8X2 Model dimensions and PC board layout on pages 255-259 252 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Low Profile Unfiltered Modular Jacks Z Series UL Recognized CSA Certified Shield 3 Shield 4 RJ11 RJ45 Z Series Specifications * Low profile Contacts: Material: Phosphor Bronze Plating: 50 microinches gold Barrier underplating: 100 microinches nickel Resistance: Initial: 20 m max. After 500 mating cycles: 30 m max. * Unfiltered * Available unshielded or shielded with board grounded shield or spring fingered panel ground interface Shield Material: Housing Material: Dielectric Withstanding Voltage: Line to Line and Line to Ground: Available Part Numbers RJ11-6Z RJ11-6Z3 RJ11-6Z4 Tin-plated copper alloy Black glass-filled polyester (VALOX 457) RJ45-8Z RJ45-8Z3 RJ45-8Z4 Printed Circuit Board Retention: Before soldering: After soldering: 1000 VAC for 60 seconds 1 lb. minimum 20 lb. minimum 6 Model dimensions and PC board layout on pages 255-259 Signal Line Products 253 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Model Dimensions L, LC, LCT and X Series RJ Jack Dimensions RJ11 - No Shield RJ11 - Style 2 Shield .900 22.86 .800 20.32 .810 20.57 .620 15.75 .520 13.21 .780 19.81 .590 14.99 .040 1.02 .04 1.02 .165 4.19 .195 4.95 .322 8.19 .165 4.19 .165 4.19 .195 4.95 .395 10.03 .485 12.32 .322 8.18 6 4 2 5 3 6 .520 13.21 4 2 1 5 .540 13.72 3 1 RJ11-2L-S RJ11-4L-S RJ11-6L-S Part No. RJ11-2L-B RJ11-4L-B RJ11-6L-B RJ11-2X RJ11-4X RJ11-6X RJ11-2LC2-S RJ11-4LC2-S RJ11-6LC2-S RJ11 - Style 1 Shield Part No. RJ11-2LC2-B RJ11-4L2-S RJ11-4LC2-B RJ11-6L2-S RJ11-6LC2-B RJ11-4L2-B RJ11 - PC Board Layout .900 22.86 .860 21.84 .840 21.34 With shield .350 8.89 .250 6.35 .322 8.18 0.76 .003 1.93 .08 .780 19.81 0.030 +.008 / -.003 .76 +.20 / - .08 (6 places) .165 4.19 .165 4.19 .322 8.18 6 1 2 3 4 5 6 2 5 3 .540 13.72 1 RJ11-6L1-B RJ11-6LCT1-S RJ11-6LCT1-B .075 1.91 .075 1.91 .210 5.33 .345 8.76 .050 1.27 (5 places) Signal Line Products 4 Part No. RJ11-2LC1-B RJ11-4L1-S RJ11-4LC1-B RJ11-6L1-S RJ11-6LC1-B RJ11-4L1-B .400 10.16 .485 12.32 6 RJ11-2LC1-S RJ11-4LC1-S RJ11-6LC1-S Edge of Board .04 1.02 .195 4.95 RJ11-6L2-B RJ11-6LCT2-S RJ11-6LCT2-B .128 .003 Dia. 3.25 .08 (2 holes) For all RJ11 L, LC, LCT and X Series Models Shown from Component Side 255 255 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Model Dimensions (continued) L, LC, LCT and X Series RJ Jack Dimensions (continued) RJ45 - No Shield RJ45 - Style 2 Shield .700 17.78 .600 15.24 .900 22.86 .800 20.32 .810 20.57 .540 13.72 .780 19.81 .04 1.02 .04 1.02 .165 4.19 .195 4.95 .322 8.18 .195 4.95 .165 4.19 .165 4.19 .395 10.03 .322 8.18 .485 12.32 8 7 8 6 7 4 5 6 5 4 3 2 2 1 1 Part No. RJ45-6L-S RJ45-8L-S RJ45-6L-B .620 15.75 3 Part No. RJ45-6LC2-S RJ45-8LC2-S RJ45-6LC2-B RJ45-8LC2-B RJ45-6L2-S RJ45-8L2-S RJ45-6L2-B RJ45-8L2-B RJ45-8LCT2-S RJ45-8LCT2-B RJ45-8L-B RJ45-6X RJ45-8X RJ45 - Style 1 Shield RJ45 - PC Board Layout .900 22.86 .860 21.84 .920 23.37 .322 8.18 .780 19.81 .030 +.008/.003 Dia. .76 +.20/-.08 (8 PLACES) 1 .04 1.02 3 .195 4.95 .076.003 Dia. 1.93.08 (4 PLACES) .350 8.89 .250 6.35 .165 4.19 .165 4.19 .450 11.43 5 7 .322 8.18 2 4 6 .050 1.27 (7 SPACES) 8 .485 12.32 8 .210 5.33 7 6 5 4 .620 15.75 3 2 .345 8.76 .090 .050 2.29 1.27 .128.003 Dia. 3.25.08 (4 PLACES) 1 RJ45-6LC1-S RJ45-6L1-S RJ45-8LCT1-S Part No. RJ45-8LC1-S RJ45-8L1-S RJ45-8LCT1-B RJ45-6LC1-B RJ45-6L1-B RJ45-8LC1-B RJ45-8L1-B For all RJ45 L, LC, LCT and X Series Models Shown from Component Side Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Model Dimensions (continued) L, LC, LCT and X Series RJ Jack Dimensions (continued) RJH - No Shield RJH - PC Board Layout .540 13.72 .440 11.18 .810 20.57 .322 8.18 .350 8.89 .250 6.35 .590 14.99 .030 +.008/-.003 Dia. .76 +20/-.08 (4 holes) .195 4.95 .300 7.62 .322 8.18 Edge of board .04 1.02 1 2 3 4 .395 10.03 .075 1.91 .050 1.27 (3 Spaces) 4 3 .128.003 Dia. 3.25.08 (2 holes) 2 1 .250 6.35 .350 8.89 Part No. RJH-4-L-B N and Z Series RJ Jack Dimensions RJ11 - Low Profile, No Shield .620 15.75 .520 13.21 RJ11 Low Profile, Style 3 Shield .710 18.03 .740 18.80 .910 Max. 23.11 .515* 13.08 .010 .25 .485 12.32 .010 .25 .120 3.05 .135 3.43 .165 4.19 .217 5.51 .135 3.43 .165 4.19 6 *to top of shield .217 5.51 .400 10.16 .430 10.92 Signal Line Products 6 6 4 2 4 5 3 .520 13.21 2 5 3 .550 13.97 1 1 Part No. Part No. RJ11-6N-B RJ11-6Z RJ11-6N3-B RJ11-6Z3 257 257 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Model Dimensions (continued) N and Z Series RJ Jack Dimensions (continued) RJ11 Low Profile, Style 4 Shield .620 15.75 RJ45 - Low Profile, No Shield .515* 13.08 .120 3.05 .710 18.03 .70 17.78 .60 15.24 .740 18.80 .485 12.32 .010 .25 .010 .254 .135 .165 3.43 4.19 .135 3.5 .165 4.2 *to top of shield .217 5.51 .430 10.92 6 4 2 .217 5.51 5 3 .550 13.97 1 Part No. RJ11-6N4-B RJ11-6Z4 RJ11 Low Profile, PC Board Layout RJ45-8N-B Part No. RJ45-8N-S RJ45-8Z RJ45 - Low Profile, Style 3 Shield .740 18.80 .99 Max. 25.15 .076.003 1.93.08 Dia. (2 PLACES) .217 5.51 .515* 13.08 .350 8.89 .250 6.35 .030 + .008/- .003 Dia. .76 +.20/-.08 (6 PLACES) 1 2 .400 10.16 3 .120 3.05 .050 (5 SPACES) 1.27 .135 .165 3.43 .4.19 *to top of shield 4 5 .217 5.51 6 .080 2.03 .40 10.16 .430 10.92 .075 1.91 .120 3.05 8 7 .128.003 Dia. 3.25.08 (2 HOLES) 6 5 4 .630 16.00 3 2 1 For all RJ11 N and Z Series Models Shown from Component Side RJ45-8N3-B Part No. RJ45-8N3-S RJ45-8Z3 258 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Model Dimensions (continued) N and Z Series RJ Jack Dimensions (continued) RJ45 Low Profile, Style 4 Shield RJ45 Low Profile PC Board Layout .740 18.80 .700 17.78 .350 8.89 .250 6.35 .217 5.51 .515* 13.08 .010 .25 .076.003 Dia. 1.93.08 (2 Places) .120 3.05 .135 3.43 .217 5.51 3 .450 11.43 *to top of shield 5 7 .430 10.92 5 3 2 .050 (7 Spaces) 1.27 4 6 8 .095 2.41 8 7 .030 +.008/-.003 Dia. .76 +.20/-.08 (8 Places) 1 .165 4.19 .120 3.05 6 4 .630 16.00 .050 1.27 .128.003 Dia. 3.25.08 (2 Places) 2 1 RJ45-8N4-B Part No. RJ45-8N4-S For all RJ45 N and Z Series Models Shown from Component Side RJ45-8Z4 6 Signal Line Products 259 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 260 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 7. Technical Notes -- Table of Contents Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .262 Understanding RFI Power Line Filters . . . . . . . . . . . . . . . . . . . . . . . . . . . . .263 Understanding Hipot Testing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .266 Understanding Leakage Current (Touch Current) . . . . . . . . . . . . . . . . . . .267 Understanding Insertion Loss . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .268 Appendix A - Conducted RFI Emissions Testing . . . . . . . . . . . . . . . . . . . .269 Appendix B - Conducted RFI Susceptibility Testing . . . . . . . . . . . . . . . . .270 Appendix C - Health Care Equipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . .270 Appendix D - Safety Agency File Numbers . . . . . . . . . . . . . . . . . . . . . . . . .271 Technical Notes 7 261 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Introduction TE Connectivity (TE) has established itself as a world leader in RFI technology by introducing the first line of catalog filter products over 50 years ago. Today, TE continues to pursue the latest in RFI filter design through testing and evaluating power supplies and studying their effects. Changing international standards obligate designers to constantly review and evaluate their filtering needs. The following section provides some basic information on RFI terminology and filter selection. Additional information can be accessed through TE's Corcom product internet pages at www.corcom.com 262 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding RFI Power Line Filters What Is Radio Frequency Interference (RFI)? RFI is unwanted electromagnetic energy in the frequency range generally used for radio communications. The frequency ranges of interest are 10kHz to 30MHz for conducted phenomena and 30MHz to 1GHz for radiated phenomena. What are the modes of propagation of RFI? RFI is propagated via radiation (electromagnetic waves in free space) and by conduction over signal lines and AC power systems. Radiated - One of the most significant contributors to radiated RFI from electronic equipment is the AC power cord. The power cord is often an efficient antenna since its length approaches a quarter wave length for the RFI frequencies present in digital equipment and switching power supplies. Conducted - RFI is conducted over the AC power system in two modes. Common mode (asymmetrical) RFI is present on both the line and neutral current paths with reference to the ground or earth path. Differential mode (symmetrical) RFI is present as a voltage between the line and neutral leads. Why Be Concerned with RFI? What are the FCC requirements? The U.S. Federal Communications Commission (FCC) has established regulations to reduce the interference potential of electronic computing devices (FCC Rules, Part 15, Subpart J). A computing device is defined as any electronic device or system that generates and uses timing signals or pulses at a rate in excess of 10,000 per second and that uses digital techniques. It is important to note that a switching power supply does not itself fall into this category, but that its emissions must still meet the limits when it is installed in a piece of equipment that is subject to the regulations. The level of emissions the equipment must meet depends on whether it is marketed for use in a residential environment (Class B) or in a commercial, industrial, or business environment (Class A). The limits for Class B are more stringent than those for Class A (see Appendix A). Most Class B equipment must undergo certification, meaning that emissions Further details on FCC requirements can be obtained from the FCC, RF Devices Branch (Authorization and Standards Division), Washington, DC 20554, (301) 725-1585. What are CE markings and RFI filters? As of January 1, 1996, electrical and electronic equipment shipped to Europe is required to be labeled with the CE marking. In order to apply the CE marking, equipment must meet the General Product Safety Directive and Electromagnetic Compatibility Directive. RFI power line filters are components and therefore not covered by the CE requirements, but they are used in electronic systems to meet EMC specifications. Two of the most common emission specifications are EN 55011 for industrial, science, and medical equipment, and EN 55022 for information technology equipment. The conducted emission limits for these specifications are the same and broken down to Class "A" and Class "B" limits. Electronic equipment that may be connected to a power main shared with a residential area must comply with the more stringent Class "B" limits. The measurement technique is done using quasi-peak and average detection, with different limits for each measure in dB above one microvolt. Technical Notes The designers and manufacturers of digital equipment must concern themselves with RFI for two reasons. (1) Their equipment must operate properly in the application environment, often in the presence of significant levels of RFI. (2) Their equipment must not emit RFI that interferes with RF communications often vital to health and safety. The necessity for reliable RF communications has given rise to legal regulations ensuring RFI control for electronic equipment. test data must be submitted to the FCC for type approval. Class A and all other Class B equipment must be verified--i.e. the manufacturer conducts his own emissions testing and verifies that he complies with the limits, but no forms need to be filed with the FCC. There are several immunity tests to which electronic equipment must comply, one of which is the electrically fast transient (EFT), IEC 61000-4-4. The equipment must continue to operate during this test. The transient wave form is a 5ns rise time with a 50ns duration. A burst is induced onto the power line at 1kV with a repetition rate of 5kHz lasting 15ms and repeated every 300ms. The test simulates switching of inductive loads and contacts. To pass the EFT test, it is important that the RFI filter's enclosure have a good RF ground with the system's chassis ground. This provides a lower impedance path from the safety ground to the system ground. The shielding effect of the RFI filter's metal enclosure eliminates radiation into the system's cabinet induced by the conducted EFT burst. Stray capacitance may occur from any of the three input power wires to chassis ground where voltage can build up from the EFT burst and cause system interrupts. The RFI filter's inductor offers an impedance to the burst. 7 263 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding RFI Power Line Filters In cases where the stray capacitances have caused multiple RF ground planes or where plastic enclosures are used, an inductive choke may be needed to provide isolation of the safety ground from the chassis ground. What Is a Power Line Interference Filter? A power line interference filter is a primary tool available to the designer of electronic equipment to control conducted RFI both into the equipment (potential equipment malfunction) and out of the equipment (potential interference to other system elements or RF communication). By controlling the RFI conducted onto the power cord, a power line filter also contributes significantly to the amount of radiated RFI. A power line filter is a multiple-port network of passive components arranged as a dual low-pass filter; one network for common mode attenuation, another network for differential mode attenuation. The network provides attenuation of RF energy in the stopband of the filter (typically above 10kHz), while passing the power current (50-60Hz) with little or no attenuation. How Does a Power Line Interference Filter Work? Power line interference filters, as passive, bilateral networks, have complex transfer characteristics, which are extremely dependent upon source and load impedance. The magnitude of this transfer characteristic describes the attenuation performance of the filter. In the power line environment, however, the source and load impedances are not defined. Therefore the industry has standardized upon the practices of verifying filter uniformity through measurement of attenuation with 50 Ohm resistive source and load terminations. This measurement is defined to the Insertion Loss (I.L.) of the filter. P (Ref) I.L. = 10 log L PL where PL (Ref) is the power transferred from the source to the load without the filter, and PL is the power transferred when a filter is inserted between the source and load. The Insertion Loss may also be expressed in terms of voltage or current ratios as shown: V (Ref) I.L. = 20 log L VL I (Ref) I.L. = 20 log L IL where VL (Ref) and IL are measured without a filter and VL and IL are measured with a filter. (continued) It is important to note that Insertion Loss does not describe the RFI attenuation provided by a filter in the power line environment. In the power line environment the relative magnitudes of the source and load impedances must be estimated and the appropriate filter configuration selected such that the greatest possible impedance mismatch occurs at each termination. This dependence of filter performance on terminated impedances is the basis for the concept of "mismatching networks." What is the concept of power line filters as "Impedance Mismatching Networks"? RFI power line filters can be thought of as "impedance mismatching networks" at higher frequencies in the attenuation band. Network analysis shows that the greater the mismatch of filter impedance to terminating impedance, the more effective the filter is in attenuating RF energies. Common mode power line impedance is considered to be low (on the order of 50 Ohms). Thus, following the concept of an impedance mismatch, Corcom power line filters employ a high common mode impedance (series inductance) on the power line side of the filter. For load (equipment) side common mode impedance mismatch, Corcom products are available with a high impedance (series inductance) or a low impedance (shunt capacitance). High (common mode) impedance filters for use with low impedance equipment include the EP, H, 6A Q, R and V series. Low (common mode) impedance filters for use with high impedance equipment include the B, EC, ED, EF, G, K, N, 3A Q, S, SK, T, W, X, Y, and Z series. Knowing the input impedance of your equipment, then, may be useful in initially selecting the filter series most likely to solve your RFI problems. However, since this impedance is almost certainly complex (having both resistive and reactive components), it may vary widely over the RFI frequency range. Hence a variety of series should be evaluated in your quest for the most effective filter in any one application. Do all filter networks with the same circuit and element values perform identically? All filter networks with the same circuit and element values do not perform identically. Element values are specified and measured at a single frequency (usually 1kHz). Filter performance is required over the entire frequency spectrum, not just at the frequency of component measurement. The type of component construction and method of incorporation into a filter are extremely important to filter performance. 264 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding RFI Power Line Filters Figure 1 illustrates the high-frequency performance difference between the three leaded capacitor construction employed by TE and a conventional method of construction. Both units would be specified by the same nominal 1kHz component value, approximately 5000pF. Figure 1: Insertion Loss db V 0 10 20 30 40 50 60 70 80 90 100 Conventional Construction (continued) How do you perform susceptibility testing? Susceptibility testing involves injection of noise onto the power input lines while monitoring the equipment for proper operation. Quantification of the noise levels to be found in the equipment environment is difficult at best. Through analysis of solutions to specific susceptibility problems, TE has developed recommended noise injection levels, which proved a high level of confidence for reliable equipment operation in the real world environment. The test methods and injection noise levels are found in Appendix B. Is installation important to filter performance? TE Connectivity Construction 20.0 40.0 60.0 Frequency MHz How Do You Select a Power Line Interference Filter? How do you perform conducted emission tests? Conducted emission testing requires a quiet RF environment--usually a shielded enclosure--a line impedance stabilization network, and an RF voltage instrument such as a tuned receiver or a spectrum analyzer. Additional testing information is given in Appendix A. The RF ambient of the test environment should be at least 20 dB below the desired compliance limit for accurate results. The line impedance stabilization network (LISN) is required to establish a desired source impedance for the power line input. This is an important part of the test procedure, since this impedance directly affects the measured emission levels. The correct bandwidth for the measurement receiver is also a critical test parameter. Normally the case of the filter is bolted to the framework or chassis of the electronic equipment it protects. The line side leads should be kept short and well separated from the load side leads. The ideal isolation system is a bulkhead-mounted filter incorporating a line cord connector, such as the Corcom EC, ED, or EF power line filter series. How Do You Know Which Filter To Test? A filter, or ordered group of filters, likely to solve your interference control problem can be obtained by using the selector chart at the front of each section. Every Corcom filter series is available in a range of current ratings and packages. Detailed specifications, including prices, are listed on the individual series' catalog sheets referenced in the selector chart. Telephone numbers of distributors who stock all TE products are listed on the back cover of this catalog. Technical Notes The only way to select and qualify a power line interference filter is to test the unit in your equipment. As mentioned above, the performance is highly dependent on equipment load impedance. Filter performance cannot be derived from single impedance (50 Ohm) insertion loss data. Performance is a complex function of filter element impedances and equipment impedances which vary in magnitude and phase over the frequency spectrum of interest. Filter selection testing should be performed in your equipment to your required level of performance for both conducted emission control (FCC, VDE) and susceptibility control. Mounting and wiring of the filter are critical influences on its performances. A power line filter is best installed at the power line input point of your equipment. The filter is a barrier to high frequency signals. Its purpose must not be defeated by stray capacitance coupling the power input leads to the power output leads, or to any other conductors in the protected equipment. Why Be Concerned with Safety Agency Requirements? All components in the AC power system, including power line filters, must be safe from potential fire and shock hazard. The standards set by the various safety agencies, like UL, CSA, VDE, and SEV, provide guidelines to assist the designer in specifying safe and reliable components. Components which carry the compliance symbols from these agencies have been designed and manufactured to comply with these standards. A summary of safety agency requirements can be found in Appendix C. 7 265 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding RFI Power Line Filters What are the significant requirements of UL and CSA? UL and CSA are primarily concerned with high potential withstand capability, temperature rise, creepage distances, and material temperature capability at the time of manufacture. What are the additional aspects of VDE safety requirements? In addition to the requirements of UL and CSA, VDE specifies limits of hipot, insulation resistance, and change of component values, at the conclusion of extreme environmental conditioning. The conditioning includes life tests at elevated temperatures, long term humidity, and temperature/humidity cycling. Components that bear the VDE symbol of safety have been designed and tested not only for initial safety but also for safety over the life of the product. How Do You Specify a Power Line Filter? The filter you have selected through system testing can best be specified by the data parameters found on the appropriate catalog page. Combining the product family parameters listed under the "specifi- (continued) cations" with the package style and dimensional data from your specific filter will adequately define your selection. Are there other parameters that need to be specified? There are three additional requirements that are often specified. Below are our recommended values: 1. Insulation Resistance: 6000 M @ 100VDC 2. Current Overload: 6 X rated current for 8 seconds 3. Humidity: 21 days at 40C 95% RH What are the test methods for verification of the important specification parameters? Some filter specifications may be unfamiliar to you or may require slightly different measuring techniques than you have been using for other components. It is very important that supplier and customer use the same techniques for verification of electrical specifications, in order to assure an uninterrupted flow of quality components. Three specifications that must be clearly understood are hipot testing, leakage current, and insertion loss. Understanding Hipot Testing The term "hipot" is an acronym for "high potential." Hipot testing stresses the insulation and capacitors of a filter assembly by applying a voltage much higher than is usually experienced in normal operation. The purpose of hipot specifications is to assure safety and reliability. All the major safety agencies require hipot testing for qualification of power line filters, and also require that each production unit undergo hipot testing to verify the integrity of the line-to-ground components and insulation. Every Corcom filter is hipot tested twice: once during assembly and again after completion. Applying hipot testing as an incoming inspection procedure requires a thorough understanding of its uses and limitations. Hipot test voltages are applied from each line (both lines tied together for VDE) to ground and from lineto-line. The line-to-ground voltages are always higher. Test voltages may be specified as AC or DC, with the DC voltages at least 1.414 times the AC voltages. For incoming inspection testing, TE recommends using the voltages given as "hipot rating" for each filter in the catalog. These DC voltages will always be equal to or higher than the peak AC voltage carried by any safety agency whose approval the filter carries. A DC hipot test is generally used. A variety of hipot testers is available from a number of manufacturers. The tester chosen should have at least a 500VA rating. The following precautions must be observed to insure the safety of the operator and the validity of the test: 1. THESE VOLTAGES CAN BE LETHAL--use the utmost safety precautions to protect the test operator. 2. The possibility of high surge currents and oscillatory overvoltage during sudden application of the test voltage requires some method of limiting the applied current or increasing the voltage comparatively slowly. 3. For AC hipot tests, use an oscillograph to monitor the applied voltage. The current limiting circuit may react with the filter circuit to distort the 60Hz waveform. This may produce a peak voltage that exceeds the expected peak value of a sinusoidal voltage having the specified rms value. The peak voltage should be 1.414 times the rms value. Higher voltages may cause unwarranted failures due to the peak currents exceeding the trip setting. 4. For line-to-line hipot testing, remember that most filters have a bleeder resistor (typical value 100k to 10M) to discharge the line-to-line capacitors. Be sure to set the trip point of the hipot tester above the current level that will flow through the bleeder resistor: 10mA is usually a safe value. 266 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding Leakage Current (Touch Current) Leakage current (also referred to as "touch current") is an important specification of power line filters. There has always been an undeserved negative connotation to this term. Leakage current is not a function of the quality of components, but is a direct function of the line-to-ground capacitance value. The larger the capacitance, the lower the impedance to common mode currents, and the greater the common mode interference rejection. Hence, leakage current is a measure of filter performance--the higher, the better. Why, then, do safety agencies specify a maximum allowable leakage current? This is done in order to limit the magnitude of expected ground return currents. The line-to ground capacitors provide a path for 50/60Hz current to flow to the chassis. As long as the equipment is grounded, these currents will flow in the ground circuit and present no hazard. However, in the unlikely but always possible circumstance where the ground circuit is faulty, the earth connection may be established by the body of a person. If this should occur, the maximum leakage current specification limits the ground return current to a safe value, typically 0.5 to 5.0mA. The limits set by safety agencies are based on end user equipment specifications, such as those given below. Capacitive Current Limits Limits for Class I Grounded Equipment Specification U.S.A. UL 60950 Canada C22.2 No. 60950 3.5 mA, 120V, 60Hz Europe EN 60950 3.5 mA, 120V, 60Hz Variac Filter Under Test Isolation Transformer 60HzAC Input Voltage No Connection To Load Terminals 120V, 60Hz or 250V, 60Hz 1500 H N 0.15 Note that filter case must be floating, not grounded. The circuit of Figure 2 illustrates the measurement technique for leakage current. The leakage limits apply to each side of the line independently. The test circuit provides the correct value by shunting the line-to-ground path that is not being measured by the millimeter impedance. This test is realistic, because power to a system is provided by a hot line and a neutral line, with the neutral basically at ground potential, thus providing no addition to the leakage. Note that the leakage current is directly proportional to line voltage and frequency. Hence, it is unwise to specify an operation frequency greater than 60Hz (e.g., 400Hz) when leakage current limits must also be met. Technical Notes Country Figure 2: Leakage Current Measurement 3.5 mA, 250V, 50Hz Since the largest component of leakage current is usually from the power line filter, it is prudent to set a maximum leakage current limit for the filter itself. There has been a tendency in the industry to specify the minimum leakage current to comply with all agency requirements, usually 0.5mA. This specification decision should not be made arbitrarily, because often the size and cost of the filter can be reduced by allowing a greater maximum leakage current. 7 267 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding Insertion Loss What is insertion loss? Insertion loss is the ratio (expressed in dB) of the signal voltage transferred from source to load without a filter, to the signal voltage transferred from source to load when the filter is inserted. As discussed above ("How Does a Power Line Interference Filter Work?"), insertion loss is not a measure of filter performance in the power line equipment environment. Figure 3: CM Insertion Loss Measurement 50 The most important aspect of insertion loss measurement is consistency. It is particularly critical that supplier and user employ the same measurement techniques. The standard method of insertion loss measurement used by TE is as follows: Insertion loss is easily measured with a spectrum analyzer or tuned receiver and a tracking generator. A zero dB reference is established without the filter. Then the filter is inserted, and the attenuation provided over the desired frequency range is recorded. 50 Spectrum Analyzer Common Mode (CM) -- signals present on both sides of the line (hot and neutral) referenced to ground. Differential Mode (DM) -- signals present on one side of the line, referenced to the other. Test Connection 50 50 Spectrum Analyzer Tracking Generator Reference Connection For differential mode, the signals on the line and neutral terminals are of the same magnitude but opposite phase. Current circulates between the line and neutral leads only. DM insertion loss is tested with 50 Ohm 180 power splitters as shown in Figure 4. All DM insertion loss data published in the Corcom product guide are measured this way. Figure 4: DM Insertion Loss Measurement Splitter L 50 o 180 L FILTER 180 o 50 Spectrum Analyzer L G N Tracking Generator Test Connection Accordingly, we may deal with CM insertion loss or DM insertion loss or both. For the common mode, the line and neutral terminals are at the same potential (same magnitude and phase) and may be considered as being in parallel. CM current circulates between this pair and the common (ground) lead. CM insertion loss is measured by strapping the line and neutral terminals together on both sides of the filter (Figure 3). All CM insertion loss data published in the Corcom product catalog are measured this way.For differential mode, the signals on the line and neutral terminals are of the same magnitude but opposite phase. Current circulates between the line and neutral leads only. DM insertion loss is tested with 50 Ohm 180 power splitters as shown in Figure 4. All DM insertion loss data published in the Corcom product catalog are measured this way. G G 50 For a power line filter we are interested in signal attenuation in two different modes: L N Tracking Generator How is it measured? If the terminating impedances are standardized, then it becomes meaningful to measure insertion loss, but the results so obtained can be applied only to an identical circuit. The most popular set-up is to make the source and load impedances each 50 Ohms, resistive. L N 50 Splitter I DM 50 o o 180 Tracking Generator 180 I DM 50 Spectrum Analyzer Reference Connection Note that all signal leads in Figures 3 and 4 are 50 Ohm coaxial cables. 1. Make your 0dB reference measurement over the entire frequency range, not just at one or two points. 2. Make sure the filter case has a good RF ground connection. 3. Make sure the wiring to the load side of the filter is well separated from the wiring to the line side, to avoid RF coupling around the filter. 268 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Understanding Insertion Loss What can it be used for? Standardized insertion loss data will not accurately predict a filter's performance in your equipment. However, it does serve as an important tool for verifying product consistency through incoming inspection. The criterion for acceptance would be that the measured insertion loss must either meet or exceed the (continued) published data when tested in the standardized manner. Accordingly, "typical" insertion loss data is not meaningful. The data to which you test should be minimum values. Most of the insertion loss data published by TE are guaranteed minimums, and as such can be tested for a positive indication of component consistency. Appendix A - Conducted RFI Emissions Testing Conducted RFI Emissions Testing Figure A2 Since conducted emissions testing is usually done to insure that your equipment will comply with the limits of FCC Part 15 or EN55022, the test methods used should conform to the specifications of these two agencies. You will need the following equipment: FCC Part 15 and EN55022 80 1. Shielded room, to allow measurement with minimal background interference. 60 2. Two 50 Ohm line impedance stabilization networks (LISNs), fixing the line-side impedances as mandated by FCC and CISPR. 40 QUASI-PEAK CLASS A AVERAGE CLASS A QUASI-PEAK CLASS B AVERAGE CLASS B .1 .15 3. Spectrum analyzer or tuned receiver, with CISPR quasipeak detector, covering the range from 10kHz to 30MHz. .5 1 5 10 30 Frequency in MHz Figure A1 250 H 1.2 8 .25 10 5 1000 10 5 1000 1.2 8 .25 250 H Technical Notes To Power Source 50 H 50 50 H Line Impedence Stabalization Network 50 Spectrum Analyzer Equipment 7 The limits for FCC Part 15 and EN55022 are shown in Figure A2. To which one or more of these limits you will test is determined by whether your equipment is marketed in the United States (FCC) or Europe (EN55022) and into which class of operation it falls at each agency. 269 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Appendix B - Conducted RFI Susceptibility Testing Conducted RFI Susceptibility Testing You can determine whether or not your equipment is susceptible to conducted RFI by subjecting it to predetermined levels of CM and DM interferences, and noting any malfunctions that occur. Such a test approximates real-world interference by standardized test conditions, according to previous experience. TE's recommendation for conducted susceptibility testing follows. The equipment required will be: A. Common Mode 50 H L 5 To Power Source 8 F 1000 8 F 1000 50 1. Shielded room, to eliminate spurious signals. 2. Two 50 Ohm line impedance stabilization networks (LISNs). 3. 50 Ohm signal generator, 1 Watt output. 7 Volts from 10kHz to 150kHz 2 Volts from 150kHz to 500kHz 1 Volt from 500kHz to 30MHz Pulse waveforms should be injected common mode and differential mode, pulse width 10 microseconds, rise time 1 microsecond, repetition rate 60Hz and varied in phase 0 to 360 degrees on the 60Hz power waveform. CM pulses should have peak levels of 2 volts; DM pulses should have peak levels of twice the rated line voltage. These levels are based on emission data gathered at TE and are considered typical of the levels encountered close to high noise sources. 1 F 5 N 4. 50 Ohm (or less) pulse generator, 0 to 300 Volts output. CW signals should be injected common-mode, using peak levels of: 1 F 50 F Equipment Line Impedence Stabalization Network B. Differential Mode 50 H L To Power Source 5 1 F 8 F 50 8 F 1 F 5 N 50 F Line Impedence Stabalization Network Equipment Figure A3 Appendix C - Health Care Equipment UL 60601-1 Medical Electrical Equipment The major safety standard for electro-medical devices is the IEC 60601 series, with the IEC 60601-1 standard covering all generic requirements. This standard is the basis of the various harmonized equivalents, the European equivalent is EN 60601, the UL equivalent is UL60601-1 and the CSA equivalent is C22.2 No. 60601-1 Underwriters Laboratories' medical electrical equipment specification is broken down into two basic categories. A. Patient Care Equipment: "Equipment that is intended to be used on or with, or likely to be contacted by, a patient in a health care facility in the course of his treatment." This equipment can have a maximum leakage current of 100 A at 120VAC, 60Hz. B. Non-patient Equipment: "Equipment primarily for use in a health care facility that is intended for use where contact with a patient is unlikely." This equipment can have a maximum leakage current of 300 A at 120VAC, 60Hz. All filters starting with "H" and "M" are for medical equipment applications. They can be used in both patient care equipment and non-patient equipment. All other Corcom products with an "E" in the part number are suitable for use only in (120V) non-patient equipment. 270 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Appendix D - Safety Agency File Numbers Filters Power Entry Modules UL Recognition UL Recognition Guide FOKY2, File E48570 Guide FOKY2, File E48570 All except IK series All filtered power entry modules Guide ECBT2, File E106884 Guide AXUT2, File E61290 Non-filtered DB Series connectors only All non-filtered fuseless modules and 15SRB with suffix 1, 2, 8, P, S1 or S8 Guide AYVZ2, File E59193 Component Recognized by UL to Canadian Requirements All non-filtered fused modules Guide ECBT8, File E106884 Non-filtered DB Series connectors only Component Recognized by UL to Canadian Requirements Component Recognized by UL to Canadian Requirements Guide AXUT8, File E61290 Models: 15CE1, 15CS1, 15CBE1, 15CBS1 and 15CU Series UL Guide FOKY2, File E48570 CSA Guide FOKY8, File E48570 AFC, FFA, FFD and DFC Series only CSA Certification Class 2221, File LR46870 UL Listing Filtered modules Guide FNFT, File E117533 Class 6221, File LR68190 Model 3FL3 ballast filter Non-filtered modules TUV Approval CSA Certification File T72051210.01 Class 2221, File LR46870 Non-filtered DC rated P Series with VDE rating only All except IK series VDE Approval VDE Approval File 706400-4730 Technical Notes File 706400-4730 All except IK series All filtered modules except J Series File 706400-1550 TUV Approval All non-filtered modules except J Series File E2173035 DAF, DAS Series File E2173028.01 DCB, DCF Series File T72091763.01 Accessories Filtered DB Series File T72081913.01 Non-filtered DB Series (Connectors) Signal Sentry Modular Jacks UL Recognition Guide ECBT2, File E106884 MA100 7 Guide XUHT2 File E106794 TS Series UL Recognition Guide DUXR2, File E136872 CSA Certification Class 6233, File LR88865 CSA Certification MA100 Class 4872, File LR96220 271 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 272 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 1CFE1 1CFS1 1CHE1 1CHS1 1CUFE1 1CUFF1 1CUFS1 1EAH1 1EAS1 1EB1 1EB3 1EBF1 1EBF4 1EBH1 1EBP 1EBS1 1EC1 1EC2 1EC4 1EC8 1ED1 1ED2 1ED4 1ED8 1EDK1 1EDK3 1EDP 1EEA1 1EEA2 1EEAP 1EEB1 1EEB2 1EEBP 1EEJ1 1EEJ2 1EEJ8 1EEJP 1EF1F 1EF2F 1EF4 1EF8 1EGG1-1 1EGG1-2 1EGG1C-1 1EGG1C-2 1EGG8-1 1EGG8-2 1EGG8C-1 TE Ordering Number 6609113-1 6609113-2 6609114-1 6609114-2 2-1609113-2 2-1609114-2 2-1609113-7 6609002-1 6609005-6 6609020-1 6609020-2 6609018-1 6609018-2 6609003-1 6609063-1 1-6609005-1 6609017-1 6609017-2 6609017-3 6609017-4 6609016-1 6609016-2 6609016-3 6609016-4 6609033-1 6609033-2 6609065-1 6609000-1 6609000-2 6609000-3 6609001-1 6609001-2 6609001-3 6609006-1 6609006-2 3-6609006-2 6609006-3 6609015-1 6609015-2 6609014-3 6609014-4 6609115-1 6609115-3 6609115-4 6609115-5 6609115-6 6609115-7 6609115-8 Page Number 130 130 130 130 134 134 134 149 149 15 15 138 138 149 21 149 141 141 141 141 144 144 144 144 18 18 21 149 149 149 149 149 149 154 154 154 154 160 160 160 160 166 166 166 166 166 166 166 Catalog Number 1EGG8C-2 1EGS1-1 1EGS1-2 1EHG1-2 1EHG8-2 1EHGS1-2 1EJH1 1EJH2 1EJH8 1EJHP 1EJHS1 1EJHS8 1EJM1 1EJM8 1EJMS1 1EJMS8 1EJS1 1EJS8 1EJT1 1EJT8 1EK1 1EK3 1EOP 1ER1 1ER3 1EZP 1IK1C 1VB1 1VB3 1VDK1 1VDK3 1VK1 1VK3 1VR1 1VR3 2EB1 2EB3 2EDL1S 2EDL1SC 2EDL1SCM 2EDL1SM 2EDL4 2EDL4C 2EDL4CM 2EDL4M 2EK1 2EK3 2ER1 TE Ordering Number 6609115-9 6609117-1 6609117-2 6609116-1 1-1609117-4 1609988-1 6609008-1 6609008-6 2-6609008-8 6609008-7 1-6609008-6 2-6609008-2 6609985-1 1-6609985-3 6609985-7 1-6609985-8 6609006-4 3-6609006-7 2-6609006-1 2-6609006-6 6609027-1 6609027-2 6609064-1 6609031-1 6609031-2 6609062-1 1-6609085-1 6609021-1 6609021-2 6609034-1 6609034-2 6609028-1 6609028-2 6609032-1 6609032-2 6609020-3 6609020-4 6609122-1 6609122-2 6609122-3 6609122-4 6609122-5 6609122-7 6609122-9 1-6609122-0 6609027-3 6609027-4 1609031-3 Page Number 166 166 166 166 166 166 154 154 154 154 154 154 154 154 154 154 154 154 163 163 49 49 21 61 61 92 46 15 15 18 18 49 49 61 61 15 15 176 176 176 176 176 176 176 176 49 49 61 273 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 2ER3 2EYP 2EZP 2RJ11-6L-B 2VB1 2VB3 2VK1 2VK3 2VR1 2VR3 3AYO1 3CFE1 3CFS1 3CHE1 3CHS1 3CUFE1 3CUFF1 3CUFS1 3DAF1 3DAFP 3DAS1 3EAH1 3EAS1 3EB1 3EB3 3EBF1 3EBF4 3EBH1 3EBP 3EBS1 3EC1 3EC2 3EC4 3EC8 3ED1 3ED2 3ED4 3ED8 3EDK1 3EDK3 3EDP 3EEA1 3EEA2 3EEAP 3EEB1 3EEB2 3EEBP 3EEJ1 TE Ordering Number 6609031-4 6609061-2 6609062-2 3-6609208-6 6609021-3 6609021-4 6609028-3 6609028-4 6609032-3 6609032-4 6609066-1 6609113-5 6609113-6 6609114-5 6609114-6 2-1609113-3 2-1609114-3 2-1609113-8 6609075-4 6609075-3 1-6609075-7 6609002-2 6609005-7 6609020-5 6609020-6 6609018-3 6609018-4 6609003-2 6609063-2 1-6609005-2 6609017-5 6609017-6 6609017-7 6609017-8 6609016-5 6609016-6 6609016-7 6609016-8 6609033-3 6609033-4 6609065-2 6609000-4 6609000-5 6609000-6 6609001-4 6609001-5 6609001-6 6609006-5 Page Number 61 92 92 248 15 15 49 49 61 61 111 130 130 130 130 134 134 134 212 212 212 149 149 15 15 138 138 149 21 149 141 141 141 141 144 144 144 144 18 18 21 149 149 149 149 149 149 154 Catalog Number 3EEJ2 3EEJ8 3EEJP 3EF1F 3EF2F 3EF4 3EF8 3EGG1-1 3EGG1-2 3EGG1C-1 3EGG1C-2 3EGG8-1 3EGG8-2 3EGG8C-1 3EGG8C-2 3EGS1-1 3EGS1-2 3EH1 3EH3 3EHG1-2 3EHG8-2 3EHGS1-2 3EHQ1 3EHQ3 3EHQ8 3EHQ8M 3EHQ8M 3EHT1 3EHT3 3EHT7 3EHT7M 3EHZ1 3EJH1 3EJH2 3EJH8 3EJHP 3EJHS1 3EJHS8 3EJM1 3EJM8 3EJMS1 3EJMS8 3EJS1 3EJS8 3EJT1 3EJT8 3EK1 3EK3 TE Ordering Number 6609006-6 3-6609006-3 6609006-7 6609015-3 6609015-4 6609014-7 6609014-8 1-6609115-1 1-6609115-2 1-6609115-3 1-6609115-5 1-6609115-7 1-6609115-8 1-6609115-9 2-6609115-0 6609117-3 6609117-4 6609012-1 6609012-2 6609116-2 1-1609117-5 1609988-2 6609054-1 6609054-2 6609054-3 6609054-4 6609054-4 6609053-1 6609053-2 6609053-3 6609053-4 6609055-1 6609008-2 6609008-8 2-6609008-9 6609008-9 1-6609008-7 2-6609008-3 6609985-2 1-6609985-4 6609985-8 1-6609985-9 6609006-8 3-6609006-8 2-6609006-2 2-6609006-7 6609027-5 6609027-6 Page Number 154 154 154 160 160 160 160 166 166 166 166 166 166 166 166 166 166 169 169 166 166 166 37 37 37 37 37 40 40 40 40 43 154 154 154 154 154 154 154 154 154 154 154 154 163 163 49 49 274 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 3EK7 3EK7M 3EMC1 3EMC3 3EOP 3EP1 3EP3 3EP7 3EP7M 3EQ1 3EQ3 3EQ8 3EQ8M 3ER1 3ER3 3ER7 3ER7M 3ERK1 3ESK1 3ESK3 3ESK7 3ESK7M 3ET1 3ET3 3ET7 3EX1 3EXLA2S 3EXM1S 3EXM4 3EXM4S 3EXP 3EYP 3EZ1 3EZLA2S 3EZM1S 3EZM4 3EZM4S 3EZP 3FL3 3MV1 3VAQ3 3VAQ8F 3VAQ8FS 3VB1 3VB3 3VDK1 3VDK3 3VK1 TE Ordering Number 6609027-7 6609027-8 1-6609037-1 1-6609037-8 6609064-2 6609037-1 6609037-2 6609037-3 6609037-4 6609048-1 6609048-2 6609048-3 6609048-4 6609031-5 6609031-6 6609031-7 6609031-8 1-1609036-7 6609035-1 6609035-2 6609035-3 6609035-4 6609046-1 6609046-2 6609046-3 6609059-1 6609119-1 6609131-7 6609131-8 6609131-9 6609060-3 6609061-3 6609059-2 6609120-1 6609132-8 6609132-9 1-6609132-0 6609062-3 2-6609092-3 6609056-1 6609057-1 6609058-1 6609058-2 6609021-5 6609021-6 6609034-3 6609034-4 6609028-5 Page Number 49 49 24 24 21 27 27 27 27 58 58 58 58 61 61 61 61 65 75 75 75 75 80 80 80 92 180 184 184 184 92 92 92 180 184 184 184 92 33 54 12 12 12 15 15 18 18 49 Catalog Number 3VK3 3VK7 3VK7M 3VQ1 3VQ3 3VQ8 3VQ8M 3VR1 3VR3 3VR7 3VR7M 3VS1 3VSK1 3VSK3 3VSK7 3VSK7M 3VV1 3VW1 3VW1 4EDL1S 4EDL1SC 4EDL1SCM 4EDL1SM 4EDL4 4EDL4C 4EDL4CM 4EDL4M 4EXP 4EYP 4RJ11-6L-B 5EB1 5EB3 5EFLA2S 5EFM1 5EFM1C 5EFM1S 5EFM1SC 5EFM4 5EFM4C 5EFM4S 5EFM4SC 5EHM1 5EHM1S 5EHM4 5EHM4S 5EK1 5EK3 5EK7 TE Ordering Number 6609028-6 6609028-7 6609028-8 6609049-1 6609049-2 6609049-3 6609049-4 6609032-5 6609032-6 6609032-7 6609032-8 6609042-1 6609036-1 6609036-2 6609036-3 6609036-4 6609043-1 6609044-1 6609044-1 1-6609122-1 1-6609122-2 1-6609122-3 1-6609122-4 1-6609122-5 1-6609122-6 1-6609122-7 1-6609122-8 6609060-4 6609061-4 6609213-1 6609020-7 6609020-8 6609118-1 2-6609129-1 2-6609129-2 2-6609129-3 2-6609129-5 2-6609129-6 2-6609129-7 2-6609129-8 3-6609129-0 1-6609130-1 1-6609130-3 1-6609130-4 1-6609130-5 6609027-9 1-6609027-0 1-6609027-1 Page Number 49 49 49 58 58 58 58 61 61 61 61 68 75 75 75 75 86 86 86 176 176 176 176 176 176 176 176 92 92 248 15 15 180 184 184 184 184 184 184 184 184 184 184 184 184 49 49 49 275 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 5EK7M 5ER1 5ER3 5ER7 5ER7M 5VB1 5VB3 5VK1 5VK3 5VK7 5VK7M 5VR1 5VR3 5VR7 5VR7M 6AYO1 6CFE1 6CFS1 6CHE1 6CHS1 6CUFE1 6CUFF1 6CUFS1 6DAF1 6DAFP 6DAS1 6EAH1 6EAS1 6EBF1 6EBF4 6EBH1 6EBS1 6EC1 6EC2 6EC4 6EC8 6ED1 6ED1C 6ED2 6ED4 6ED4C 6ED8 6ED8C 6EDK1 6EDK3 6EDL1S 6EDL1SC 6EDL1SCM TE Ordering Number 1-6609027-2 6609031-9 1-6609031-0 1-6609031-1 1-6609031-2 6609021-7 6609021-8 6609028-9 1-6609028-0 1-6609028-1 1-6609028-2 6609032-9 1-6609032-0 1-6609032-1 1-6609032-2 6609066-2 6609113-9 1-6609113-0 6609114-9 1-6609114-0 2-1609113-4 2-1609114-4 2-1609113-9 6609075-6 6609075-5 2-6609075-1 6609002-3 6609005-8 6609018-5 6609018-6 6609003-3 1-6609005-3 6609017-9 1-6609017-0 1-6609017-1 1-6609017-2 6609016-9 1-6609016-1 1-6609016-0 1-6609016-2 1-6609016-4 1-6609016-3 1-6609016-5 6609033-5 6609033-6 1-6609122-9 2-6609122-0 2-6609122-1 Page Number 49 61 61 61 61 15 15 49 49 49 49 61 61 61 61 111 130 130 130 130 134 134 134 212 212 212 149 149 138 138 149 149 141 141 141 141 144 144 144 144 144 144 144 18 18 176 176 176 Catalog Number 6EDL1SM 6EDL4 6EDL4C 6EDL4CM 6EDL4M 6EDP 6EEA1 6EEA2 6EEAP 6EEB1 6EEB2 6EEBP 6EEJ1 6EEJ2 6EEJ8 6EEJP 6EF1F 6EF2F 6EF4 6EF8 6EG1 6EGG1-1 6EGG1-2 6EGG1C-1 6EGG1C-2 6EGG8-1 6EGG8-2 6EGG8C-1 6EGG8C-2 6EGS1-1 6EGS1-2 6EH1 6EH3 6EH4 6EH5 6EH8 6EH9 6EHG1-2 6EHG8-2 6EHGS1-2 6EHL1S 6EHL1SC 6EHL1SCM 6EHL1SM 6EHL4 6EHL4C 6EHL4CM 6EHL4M TE Ordering Number 2-6609122-2 2-6609122-3 2-6609122-4 2-6609122-5 2-6609122-6 6609065-3 6609000-7 6609000-8 6609000-9 6609001-7 6609001-8 6609001-9 6609006-9 1-6609006-0 3-6609006-4 1-6609006-1 6609015-5 6609015-6 1-6609014-1 1-6609014-2 6609050-1 2-6609115-2 2-6609115-3 2-6609115-4 2-6609115-6 2-6609115-8 2-6609115-9 3-6609115-0 3-6609115-1 6609117-5 6609117-6 6609012-3 6609012-4 6609013-1 6609013-4 6609013-3 6609013-2 6609116-3 1-1609117-6 1609988-3 6609123-1 6609123-2 6609123-3 6609123-4 6609123-5 6609123-6 6609123-7 6609123-8 Page Number 176 176 176 176 176 21 149 149 149 149 149 149 154 154 154 154 160 160 160 160 35 166 166 166 166 166 166 166 166 166 166 169 169 169 169 169 169 166 166 166 176 176 176 176 176 176 176 176 276 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 6EHQ1 6EHQ3 6EHQ8 6EHT1 6EHT3 6EHT7 6EHT7M 6EJH1 6EJH2 6EJH8 6EJHP 6EJHS1 6EJHS8 6EJM1 6EJM8 6EJMS1 6EJMS8 6EJS1 6EJS8 6EJT1 6EJT8 6EL1S 6EL1SC 6EL1SCM 6EL1SM 6EL4 6EL4C 6EL4CM 6EL4M 6EMC1 6EMC3 6EOP 6EP1 6EP3 6EQ1 6EQ3 6EQ8 6EQ8M 6ERK1 6ESB1 6ESK1 6ESK3 6ESK7 6ESK7M 6ESRF-3 6ESRFC3 6ESRM-3 6ESRMC2 TE Ordering Number 6609054-5 6609054-6 6609054-7 6609053-5 6609053-6 6609053-7 6609053-8 6609008-3 1-6609008-0 3-6609008-0 1-6609008-1 1-6609008-8 2-6609008-4 6609985-3 1-6609985-5 6609985-9 2-6609985-0 1-6609006-2 3-6609006-9 2-6609006-3 2-6609006-8 6609121-1 6609121-2 6609121-3 6609121-4 6609121-5 6609121-6 6609121-7 6609121-8 1-6609037-2 1-6609037-9 6609064-3 6609037-5 6609037-6 6609048-5 6609048-6 6609048-7 6609048-8 1-1609036-8 1-1609034-1 6609035-5 6609035-6 6609035-7 6609035-8 1609133-1 1609133-2 1609133-3 1609133-4 Page Number 37 37 37 40 40 40 40 154 154 154 154 154 154 154 154 154 154 154 154 163 163 176 176 176 176 176 176 176 176 24 24 21 27 27 58 58 58 58 65 71 75 75 75 75 201 201 201 201 Catalog Number 6ESRM-P 6ET1 6ET3 6ET7 6EU1 6EUP 6EXP 6FC10 6FCD10 6HJ4-2 6HJ4-4 6IK1 6J4 6J4-2 6MV1 6RJ11-6L-B 6VAQ3 6VAQ8F 6VAQ8FS 6VDK1 6VDK3 6VG1 6VJ1 6VJ1-2 6VM1 6VM1C 6VM1S 6VM1SC 6VM2 6VM2S 6VM4 6VM4C 6VM4S 6VM4SC 6VN1 6VS1 6VSB1 6VSK1 6VSK3 6VSK7 6VSK7M 6VV1 7BCF10 7EP1 7EP3 10AFC6-A 10AFC6-B 10AYO1 TE Ordering Number 1609078-1 6609046-4 6609046-5 6609046-6 6609045-2 6609045-1 6609060-6 6609069-1 6609070-1 6609126-1 6609126-2 1609973-4 6609125-1 6609125-2 6609056-2 6609213-2 6609057-3 6609058-3 6609058-4 6609034-5 6609034-6 6609051-1 6609124-1 6609124-2 2-6609128-6 2-6609128-7 2-6609128-8 2-6609128-9 3-6609128-0 3-6609128-1 3-6609128-3 3-6609128-4 3-6609128-5 3-6609128-7 6609052-1 6609042-2 1-1609034-2 6609036-5 6609036-6 6609036-7 6609036-8 6609043-2 1609989-1 2-6609037-4 2-6609037-5 1609990-1 1609990-2 6609066-3 Page Number 201 80 80 80 84 84 92 30 119 172 172 46 172 172 54 248 12 12 12 18 18 35 172 172 184 184 184 184 184 184 184 184 184 184 56 68 71 75 75 75 75 86 113 27 27 236 236 111 277 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 10CBE1 10CBS1 10CE1 10CFE1 10CFS1 10CHE1 10CHS1 10CS1 10CUFE1 10CUFF1 10CUFS1 10DAF1 10DAFP 10DAS1 10DFC6-C 10EAH1 10EAS1 10EB1 10EB3 10EBF1 10EBF4 10EBH1 10EBS1 10EC1 10ED1 10ED1C 10EDK1 10EDK3 10EDP 10EEA1 10EEA2 10EEAP 10EEB1 10EEB2 10EEBP 10EEJ1 10EEJ2 10EEJ8 10EEJP 10EF1F 10EF1FC 10EG1 10EGG1-1 10EGG1-2 10EGG8-1 10EGG8-2 10EGS1-1 10EGS1-2 TE Ordering Number 1609112-1 1609112-2 1609112-3 1-6609113-3 1-6609113-4 1-6609114-3 1-6609114-4 1609112-8 2-1609113-5 2-1609114-5 2-1609114-0 6609075-8 6609075-7 2-6609075-5 1609992-1 6609002-5 6609005-9 6609020-9 1-6609020-0 6609018-7 6609018-8 6609003-4 1-6609005-4 1-1609017-3 1-6609016-6 1-6609016-7 6609033-7 6609033-8 6609065-4 1-6609000-0 1-6609000-1 1-6609000-2 1-6609001-0 1-6609001-1 1-6609001-2 1-6609006-3 1-6609006-4 3-6609006-5 1-6609006-5 6609015-7 6609015-8 6609050-2 3-1609115-4 3-1609115-3 3-1609115-5 3-1609115-6 1609117-7 1609117-8 Page Number 130 130 130 130 130 130 130 130 134 134 134 212 212 212 239 149 149 15 15 138 138 149 149 141 144 144 18 18 21 149 149 149 149 149 149 154 154 154 154 160 160 35 166 166 166 166 166 166 Catalog Number 10EH1 10EH3 10EH4 10EH4C 10EHG1-2 10EHG8-2 10EHGS1-2 10EHT1 10EHT3 10EJH1 10EJH2 10EJH8 10EJHP 10EJHS1 10EJHS8 10EJM1 10EJM8 10EJMS1 10EJMS8 10EJS1 10EJS8 10EJT1 10EJT8 10EK1 10EK3 10EK7 10EK7M 10EMC1 10EMC3 10EMC6 10EOP 10EP1 10EP3 10ER1 10ER3 10ER7 10ER7M 10ERK1 10ESB1 10ESB6 10ESK1 10ESK3 10ESK7 10ESK7M 10ET1 10ET3 10FFA6-BA 10FFA6-CE TE Ordering Number 6609012-5 6609012-6 6609013-5 6609013-6 6609116-4 6609116-5 1609116-6 6609053-9 1-6609053-0 6609008-4 1-6609008-2 3-6609008-1 1-6609008-3 1-6609008-9 2-6609008-5 6609985-4 1-6609985-6 1-6609985-0 2-6609985-1 1-6609006-6 4-6609006-0 2-6609006-4 2-6609006-9 1-6609027-3 1-6609027-4 1-6609027-5 1-6609027-6 1-6609037-3 2-6609037-0 2-6609037-1 6609064-4 6609037-7 6609037-8 1-6609031-3 1-6609031-4 1-6609031-5 1-6609031-6 2-1609089-5 1-1609034-3 1-1609034-4 6609035-9 1-6609035-0 1-6609035-1 1-6609035-2 6609046-7 6609046-8 1609991-1 1609991-9 Page Number 169 169 169 169 166 166 166 40 40 154 154 154 154 154 154 154 154 154 154 154 154 163 163 49 49 49 49 24 24 24 21 27 27 61 61 61 61 65 71 71 75 75 75 75 80 80 230 230 278 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 10FFA6-GJ 10FFD6-CA 10FFD6-HE 10MV1 10VB1 10VB3 10VB6 10VDK1 10VDK3 10VG1 10VK1 10VK3 10VK6 10VK7 10VK7M 10VN1 10VR1 10VR3 10VR6 10VR7 10VR7M 10VS1 10VSB1 10VSB6 10VSK1 10VSK3 10VSK7 10VSK7M 10VT1 10VT3 10VV1 10VW1 12EP1 12EP3 12FC10 12FC10B 12FCD10 12FCD10B 15CBE1 15CBS1 15CE1 15CS1 15CU10BS1 15CU10S1 15CU15BS1 15CU15S1 15CUBE1 15CUBS1 TE Ordering Number 1-1609991-8 1609993-1 1609993-7 6609056-3 6609021-9 1-6609021-0 1-6609021-2 6609034-7 6609034-8 6609051-2 1-6609028-3 1-6609028-4 1-6609028-8 1-6609028-5 1-6609028-6 6609052-2 1-6609032-3 1-6609032-4 1-6609032-5 1-6609032-6 1-6609032-7 6609042-3 1-1609034-5 1-1609034-6 6609036-9 1-6609036-0 1-6609036-1 1-6609036-2 6609047-1 6609047-2 6609043-3 6609044-3 2-6609037-6 2-6609037-7 6609069-2 1609976-3 6609070-2 6609974-4 1-1609112-4 1-1609112-3 1-1609112-2 1-1609112-1 1-1609112-7 1-1609112-6 1-1609112-9 1-1609112-8 2-1609114-8 1-1609112-5 Page Number 230 233 233 54 15 15 15 18 18 35 49 49 49 49 49 56 61 61 61 61 61 68 71 71 75 75 75 75 80 80 86 86 27 27 30 30 119 119 130 130 130 130 134 134 134 134 134 134 Catalog Number 15CUE1 15CUFE1 15CUFF1 15CUFS1 15CUS1 15DAF1 15DAFP 15DAS1 15DCB10 15DCB10B 15DCB10BF 15DCB10F 15DCB6 15DCB6B 15DCB6BF 15DCB6F 15DCF10 15DCF10B 15DCF6 15DCF6B 15ED1 15ED8 15EEJ1 15EEJ2 15EEJ8 15EEJP 15EF1F 15EH4 15EHT1 15EHT6 15EJH1 15EJH2 15EJH8 15EJHP 15EJHS1 15EJHS8 15EJM1 15EJM8 15EJMS1 15EJMS8 15EJS1 15EJS8 15EJT1 15EJT8 15EMC1 15EMC3 15EMC6 15ERK1 TE Ordering Number 2-1609114-7 2-1609113-6 2-1609114-6 2-1609114-1 2-1609114-9 1-6609075-0 6609075-9 2-6609075-9 4-6609074-1 4-6609074-3 4-6609074-4 4-6609074-2 2-6609074-1 2-6609074-3 2-6609074-4 2-6609074-2 1-6609074-1 1-6609074-2 6609074-1 6609074-2 1-6609016-8 1-6609016-9 1-6609006-7 1-6609006-9 3-6609006-6 2-6609006-0 6609015-9 6609013-7 1-6609053-1 1-6609053-2 6609008-5 1-6609008-4 3-6609008-2 1-6609008-5 2-6609008-0 2-6609008-6 6609985-5 1-6609985-7 1-6609985-1 2-6609985-2 1-6609006-8 4-6609006-1 2-6609006-5 3-6609006-0 1-6609037-4 2-6609037-2 2-6609037-3 2-1609089-6 Page Number 134 134 134 134 134 212 212 212 218 218 218 218 218 218 218 218 218 218 218 218 144 144 154 154 154 154 160 169 40 40 154 154 154 154 154 154 154 154 154 154 154 154 163 163 24 24 24 65 279 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 15ET1 15ET6 15SRB1 15SRB1-Q 15SRB1-R 15SRB1-S 15SRB1-T 15SRB1-W 15SRB1-X 15SRB1-Y 15SRB1-Z 15SRB2 15SRB2-Q 15SRB2-R 15SRB2-S 15SRB2-T 15SRB2-W 15SRB2-X 15SRB2-Y 15SRB2-Z 15SRB8 15SRB8-Q 15SRB8-R 15SRB8-S 15SRB8-T 15SRB8-W 15SRB8-X 15SRBP 15SRBP-Q 15SRBP-R 15SRBP-S 15SRBP-T 15SRBP-W 15SRBP-X 15SRBP-Y 15SRBP-Z 15SRBS1 15SRBS1-Q 15SRBS1-R 15SRBS1-S 15SRBS1-T 15SRBS1-W 15SRBS1-X 15SRBS1-Y 15SRBS1-Z 15SRBS8 15SRBS8-Q 15SRBS8-R TE Ordering Number 6609046-9 1-6609046-0 6609987-9 6609987-1 6609987-2 6609987-3 6609987-4 6609987-5 6609987-6 6609987-7 6609987-8 5-6609987-4 4-6609987-6 4-6609987-7 4-6609987-8 4-6609987-9 5-6609987-0 5-6609987-1 5-6609987-2 5-6609987-3 1-6609987-8 1-6609987-0 1-6609987-1 1-6609987-2 1-6609987-3 1-6609987-4 1-6609987-5 4-6609987-5 3-6609987-7 3-6609987-8 3-6609987-9 4-6609987-0 4-6609987-1 4-6609987-2 4-6609987-3 4-6609987-4 2-6609987-7 1-6609987-9 2-6609987-0 2-6609987-1 2-6609987-2 2-6609987-3 2-6609987-4 2-6609987-5 2-6609987-6 3-6609987-6 2-6609987-8 2-6609987-9 Page Number 80 80 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 Catalog Number 15SRBS8-S 15SRBS8-T 15SRBS8-W 15SRBS8-X 15SRBX8 15SRBX8-Q 15SRBX8-R 15SRBX8-S 15SRBX8-T 15SRBX8-W 15SRBX8-X 15SRBY8 15SRBY8-Q 15SRBY8-R 15SRBY8-S 15SRBY8-T 15SRBY8-W 15SRBY8-X 15VT1 15VT6 16AFC6-B 16AFC6-C 16AFC6-G 16AFC6-H 16AYA10 16AYA6 16AYA6A 16AYC10B 16BCF10 16DFC6-C 16DFC6-G 16DFC6-H 16DFC6-N 16FC10 16FC10B 16FCD10 16FCD10B 16FFA6-CA 16FFA6-DG 16FFA6-HN 16FFD6-CA 16FFD6-HE 16IK10 16WGA1 16WGA3 16WGA7 16WGB1 16WGB3 TE Ordering Number 3-6609987-0 3-6609987-1 3-6609987-2 3-6609987-3 5-1609987-6 5-1609987-7 5-1609987-8 5-1609987-9 6-1609987-0 6-1609987-1 6-1609987-2 6-1609987-5 6-1609987-6 6-1609987-7 6-1609987-8 6-1609987-9 7-1609987-0 7-1609987-1 6609047-3 6609047-4 1609990-3 1609990-4 1609990-5 1609990-6 6609977-1 6609068-1 6609068-2 6609067-1 1609989-2 1609992-2 1609992-3 1609992-4 1609992-5 6609069-3 1609976-1 6609070-3 6609974-5 1609991-2 1-1609991-1 1-1609991-9 1609993-2 1609993-8 6609973-1 2-6609089-4 7-6609089-6 3-1609090-8 4-6609089-0 7-6609089-7 Page Number 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 204 80 80 236 236 236 236 104 104 104 108 113 239 239 239 239 30 30 119 119 230 230 230 233 233 46 89 89 89 89 89 280 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 16WGB7 16WGC1 16WGC3 16WGC7 16WGD1 16WGD3 16WGD7 16WGE1 16WGE3 16WGE7 16WGF1 16WGF3 16WGF7 20AFC6-B 20AYO1 20AYP6C 20AYT6C 20EB1 20EDK1 20EEJ1 20EEJ8 20EJH1 20EJH8 20EJS1 20EJS8 20EJT1 20EJT8 20EK1 20EMC1 20EMC6 20EP1 20EP6 20EQ1 20ER1 20ERK1 20ESB1 20ESB6 20ESK6 20ESRM-3 20ESRMC2 20ET1 20ET6 20MV1 20VB1 20VB6 20VDK1 20VDK6 20VK1 TE Ordering Number 3-1609090-9 4-6609089-1 7-6609089-8 4-1609090-0 4-6609089-6 7-6609089-9 4-1609090-1 4-6609089-7 8-6609089-0 4-1609090-2 4-6609089-8 8-6609089-1 4-1609090-3 1609990-7 6609066-4 6609072-1 6609073-1 1-6609020-1 6609033-9 6609007-3 6609007-6 6609009-4 6609009-5 6609007-5 6609007-7 6609007-8 3-6609006-1 1-6609027-7 1-6609037-5 1-6609037-7 6609037-9 1-6609037-0 6609048-9 1-6609031-7 2-1609089-7 1-1609034-7 1-1609034-8 1-6609035-3 4-1609134-7 4-1609134-8 1-6609046-1 1-6609046-2 6609056-4 1-6609021-1 1-6609021-3 6609034-9 1-6609034-0 1-6609028-7 Page Number 89 89 89 89 89 89 89 89 89 89 89 89 89 236 111 99 99 15 18 154 154 154 154 154 154 163 163 49 24 24 27 27 58 61 65 71 71 75 201 201 80 80 54 15 15 18 18 49 Catalog Number 20VK6 20VP1 20VP6 20VQ1 20VR1 20VR6 20VS1 20VS6 20VSB1 20VSB6 20VSK6 20VT1 20VT6 20VV1 20VV6 20VW1 20VW6 25AYA6 25AYA6A 25AYC10B 25FC10 25FC10B 25FCD10 25FCD10B 30AYP6C 30AYT6C 30BCF10 30DCB10 30DCB10B 30DCB10BF 30DCB10F 30DCB6 30DCB6B 30DCB6BF 30DCB6F 30DCF10 30DCF10B 30DCF6 30DCF6B 30EMC6 30ESB6 30ESK6 30ESK6C 30VB6 30VK6 30VK6C 30VSB6 30VSK6 TE Ordering Number 1-6609028-9 6609038-1 6609038-2 6609049-5 1-6609032-8 1-6609032-9 6609042-4 6609042-5 1-1609034-9 2-1609034-0 1-6609036-3 6609047-5 6609047-6 6609043-4 6609043-5 6609044-4 6609044-5 6609068-3 6609977-2 6609068-4 6609069-4 6609976-2 6609070-4 6609974-9 6609072-2 6609073-2 1609989-3 4-6609074-5 4-6609074-7 4-6609074-8 4-6609074-6 2-6609074-5 2-6609074-7 2-6609074-8 2-6609074-6 1-6609074-3 1-6609074-4 6609074-3 6609074-4 1-6609037-6 2-1609034-1 1-6609035-4 1-6609035-5 1-6609021-4 2-6609028-0 2-6609028-1 2-1609034-2 1-6609036-4 Page Number 49 27 27 58 61 61 68 68 71 71 75 80 80 86 86 86 86 104 104 108 30 30 119 119 99 99 113 218 218 218 218 218 218 218 218 218 218 218 218 24 71 75 75 15 49 49 71 75 281 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number 30VSK6C 32AFC6-B 32AFC6-C 32AFC6-F 32AFC6-G 32AFC6-H 32DFC6-C 32DFC6-G 32DFC6-H 32DFC6-N 32FFA6-CA 32FFA6-DH 32FFA6-HN 32FFD6-CA 32FFD6-HE 35IK10 36AYA10 36AYA6 36AYA6A 36AYC10B 36FC10 36FC10B 36FCD10 36FCD10B 40VK6 40VK6C 40VSK6 42BCF10 45AYP6C 45AYT6C 50AYA6 50AYA6A 50FC10 50FC10B 50FCD10 50FCD10B 50FCD10BS 50FCD10BS 50IK10 55BCF10 60AYP6C 60AYT6C 60DB8 60DBF8 60DBJ8 60DBP 60DBPL1 60DBPL3 TE Ordering Number 1-6609036-5 1609990-8 1609990-9 1-1609990-1 1-1609990-2 1-1609990-3 1609992-6 1609992-7 1609992-8 1609992-9 1609991-3 1-1609991-2 2-1609991-1 1609993-3 1609993-9 6609973-2 6609068-6 6609068-5 6609977-3 6609067-2 6609069-5 1609976-4 6609070-5 1-6609974-1 2-6609028-3 2-6609028-4 1-6609036-6 1609989-4 6609072-3 6609073-3 6609068-7 6609068-8 6609069-6 6609069-7 6609070-6 1-6609974-3 1-6609974-6 1-6609974-6 1609973-5 1609989-5 6609072-4 6609073-4 4-1609075-4 4-1609075-5 4-1609075-6 5-1609075-7 4-1609075-9 5-1609075-0 Page Number 75 236 236 236 236 236 239 239 239 239 230 230 230 233 233 46 104 104 104 108 30 30 119 119 49 49 75 113 99 99 104 104 30 30 119 119 119 119 46 113 99 99 214 214 214 214 214 214 Catalog Number 60DBPL9 60DBR 60DBRL1 60DBRL3 60DBX8 60DCB10 60DCB10B 60DCB10BF 60DCB10F 60DCB6 60DCB6B 60DCB6BF 60DCB6F 60DCF10 60DCF10B 60DCF6 60DCF6B 60VK6 60VS6 63ADT6 63ADT6S 63AFC6-C 63AFC6-G 63AFC6-H 63AYA10 63AYA6A 63AYC10B 63DFC6-C 63DFC6-G 63DFC6-H 63DFC6-N 63FFA6-GB 63FFA6-JK 63FFA6-NP 63FFD6-HB 63FFD6-NH 75BCF10 80AYC10B 80FCD10B 80FCD10BS 80IK10 100ADT6 100ADT6S 100AFC6-H 100AFC6-H 100AFC6-K 100AFC6-N 100AYA6A TE Ordering Number 5-1609075-1 5-1609075-6 6-1609075-4 6-1609075-5 4-1609075-7 4-6609074-9 5-6609074-1 5-6609074-2 5-6609074-0 2-6609074-9 3-6609074-1 3-6609074-2 3-6609074-0 1-6609074-5 1-6609074-6 6609074-5 6609074-6 2-6609028-5 1609042-6 1609071-2 1609071-1 1-1609990-4 1-1609990-5 1-1609990-6 1609977-5 6609977-8 6609067-3 1-1609992-1 1-1609992-2 1-1609992-3 1-1609992-4 1609991-4 1-1609991-3 2-1609991-2 1609993-4 1-1609993-1 1609989-6 6609067-4 6609070-7 1-6609974-7 6609973-3 1609071-4 1609071-3 1-1609990-8 1-1609990-8 1-1609990-9 2-1609990-1 6609977-7 Page Number 214 214 214 214 214 218 218 218 218 218 218 218 218 218 218 218 218 49 68 101 101 236 236 236 104 104 108 239 239 239 239 230 230 230 233 233 113 108 119 119 46 101 101 236 236 236 236 104 282 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog TE Number Ordering Number 100BCF10 1609989-7 100DCB10 5-6609074-3 100DCB10B 5-6609074-5 100DCB10BF 5-6609074-6 100DCB10F 5-6609074-4 100DCB6 3-6609074-3 100DCB6B 3-6609074-5 100DCB6BF 3-6609074-6 100DCB6F 3-6609074-4 100DCF10 1-6609074-7 100DCF10B 1-6609074-8 100DCF6 6609074-7 100DCF6B 6609074-8 100DFC6-G 1-1609992-5 100DFC6-H 1-1609992-6 100DFC6-N 1-1609992-7 100DFC6-P 1-1609992-8 100FFA6-HC 1609991-5 100FFA6-NP 1-1609991-4 100FFA6-PP 2-1609991-3 100FFD6-NC 1609993-5 100FFD6-PK 1-1609993-2 110AYC10B 6609067-5 110FCD10B 6609070-8 110FCD10BS 1-6609974-8 125DCB10 5-6609074-7 125DCB10B 5-6609074-9 125DCB10BF 6-6609074-0 125DCB10F 5-6609074-8 125DCB6 3-6609074-7 125DCB6B 3-6609074-9 125DCB6BF 4-1609074-0 125DCB6F 3-6609074-8 125DCF10 1-6609074-9 125DCF10B 2-6609074-0 125DCF6 6609074-9 125DCF6B 1-6609074-0 130BCF10 1609989-8 150AYC10B 6609067-6 150AYC10B-95 1609067-7 150FCD10B 6609070-9 150FCD10B-95 3-6609974-3 150FCD10BS 2-6609974-0 150FCD10BS-95 1-6609974-9 160ADT6 1609071-6 160ADT6S 1609071-5 180AYC10B 6609977-6 180BCF10 1609989-9 Page Number 113 218 218 218 218 218 218 218 218 218 218 218 218 239 239 239 239 230 230 230 233 233 108 119 119 218 218 218 218 218 218 218 218 218 218 218 218 113 108 108 119 119 119 119 101 101 108 113 Catalog Number 180FCD10B 180FCD10BS 200ADT6 200ADT6S 200AFC6-H 200AFC6-K 200AFC6-N 200AFC6-P 200AYC10B 200DFC6-H 200DFC6-N 200DFC6-P 200DFC6-R 200FFA6-HD 200FFA6-NP 200FFA6-PP 200FFD6-ND 200FFD6-RP 230FCD10B 230FCD10BS 250AFC6-H 250AFC6-K 250AFC6-N 250AFC6-P 250DFC6-P 250DFC6-Q 250DFC6-T 250FFA6-HF 250FFA6-NP 250FFA6-PP 300AFC6-H 300AFC6-K 300AFC6-N 300AFC6-P 300CFN12 300DFC6-P 300DFC6-Q 300DFC6-T 300FFA6-HF 300FFA6-NP 300FFA6-PP 400CFN12 500CFN12 600CFN12 PE000DD3D PE000DD6D PE000DDXD PE000SD3D TE Ordering Number 1-6609070-0 2-6609974-1 1609071-8 1609071-7 2-1609990-2 2-1609990-3 2-1609990-4 2-1609990-5 1609067-8 1-1609992-9 2-1609992-1 2-1609992-2 2-1609992-3 1609991-6 1-1609991-5 2-1609991-4 1609993-6 1-1609993-3 1-6609070-2 3-6609974-6 2-1609990-6 2-1609990-7 2-1609990-8 2-1609990-9 2-1609992-4 2-1609992-5 2-1609992-6 1609991-7 1-1609991-6 2-1609991-5 3-1609990-1 3-1609990-2 3-1609990-3 3-1609990-4 1609978-1 2-1609992-7 2-1609992-8 2-1609992-9 1609991-8 1-1609991-7 2-1609991-6 1-1609979-7 6609978-3 6609978-4 6609110-1 6609110-3 6609110-5 6609110-2 Page Number 119 119 101 101 236 236 236 236 108 239 239 239 239 230 230 230 233 233 119 119 236 236 236 236 239 239 239 230 230 230 236 236 236 236 116 239 239 239 230 230 230 116 116 116 223 223 223 223 283 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Part Number Index and Cross Reference Catalog Number PE000SD6D PE000SDXD PS000DD3D PS000DD6D PS000DDXD PS000SD3D PS000SD6D PS000SDXD RJ11-2L2-B RJ11-2L-B RJ11-2LC1-B RJ11-2LC1-S RJ11-2LC2-B RJ11-2LC2-S RJ11-2L-S RJ11-2X RJ11-4L1-B RJ11-4L1-S RJ11-4L2-B RJ11-4L2-S RJ11-4L-B RJ11-4LC1-B RJ11-4LC1-S RJ11-4LC2-B RJ11-4LC2-S RJ11-4L-S RJ11-4X RJ11-6L1-B RJ11-6L1-S RJ11-6L2-B RJ11-6L2-S RJ11-6L-B RJ11-6LC1-B RJ11-6LC1-S RJ11-6LC2-B RJ11-6LC2-S RJ11-6LCT1-B RJ11-6LCT1-S RJ11-6LCT2-B RJ11-6LCT2-S RJ11-6L-S RJ11-6N3-B RJ11-6N4-B RJ11-6N-B RJ11-6X RJ11-6Z RJ11-6Z3 RJ11-6Z4 TE Ordering Number 6609110-4 6609110-6 6609111-3 6609111-5 6609111-7 6609111-4 6609111-6 6609111-8 1-1609208-2 6609208-4 6609209-2 6609209-1 6609209-4 6609209-3 6609208-1 6609214-1 2-1609208-2 2-6609208-1 2-6609208-7 2-6609208-5 1-6609208-7 6609209-8 6609209-6 1-6609209-3 1-6609209-0 1-6609208-5 6609214-3 4-6609208-0 3-6609208-8 4-6609208-5 4-6609208-3 3-6609208-1 1-6609209-8 1-6609209-6 2-6609209-1 2-6609209-0 6609211-4 6609211-1 6609211-8 6609211-6 2-6609208-9 6609212-6 6609212-8 6609212-4 6609214-5 6609215-1 6609215-2 6609215-3 Page Number 223 223 223 223 223 223 223 223 247 247 249 249 249 249 247 252 247 247 247 247 247 249 249 249 249 247 252 247 247 247 247 247 249 249 249 249 250 250 250 250 247 251 251 251 252 253 253 253 Catalog TE Number Ordering Number RJ45-6L1-B 5-6609208-0 RJ45-6L1-S 4-6609208-9 RJ45-6L2-B 5-6609208-2 RJ45-6L2-S 5-6609208-1 RJ45-6L-B 4-6609208-8 RJ45-6LC1-B 2-6609209-7 RJ45-6LC1-S 2-6609209-6 RJ45-6LC2-B 2-6609209-9 RJ45-6LC2-S 2-6609209-8 RJ45-6L-S 4-6609208-7 RJ45-6X 1-6609214-0 RJ45-8L1-B 5-6609208-7 RJ45-8L1-S 5-6609208-5 RJ45-8L2-B 6-6609208-0 RJ45-8L2-S 5-6609208-9 RJ45-8L-B 5-6609208-4 RJ45-8LC1-B 3-6609209-3 RJ45-8LC1-S 3-6609209-0 RJ45-8LC2-B 4-6609209-1 RJ45-8LC2-S 3-6609209-6 RJ45-8LCT1-B 1-6609211-1 RJ45-8LCT1-S 1-6609211-0 RJ45-8LCT2-B 1-6609211-3 RJ45-8LCT2-S 1-6609211-2 RJ45-8L-S 5-6609208-3 RJ45-8N3-B 1-6609212-3 RJ45-8N3-S 1-6609212-4 RJ45-8N4-B 1-6609212-5 RJ45-8N4-S 1-6609212-6 RJ45-8N-B 1-6609212-0 RJ45-8N-S 1-6609212-2 RJ45-8X 1-6609214-1 RJ45-8X1 1-6609210-4 RJ45-8X2 1-6609214-3 RJ45-8Z 6609215-4 RJ45-8Z3 6609215-5 RJ45-8Z4 6609215-6 RJH-4L-B 6-6609208-1 Page Number 247 247 247 247 247 249 249 249 249 247 252 247 247 247 247 247 249 249 249 249 250 250 250 250 247 251 251 251 251 251 251 252 252 252 253 253 253 247 284 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Corcom Product Guide Catalog: 1654001 Issue Date: 06.2011 Engineering Notes 285 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide North American Sales Representatives ALABAMA CARTWRIGHT & BEAN, INC. IDAHO HUNTSVILLE, AL 800-242-5876 ALASKA TE CONNECTIVITY MUNDELEIN, IL 847-573-6504 PHOENIX, AZ 602-678-1955 PLANO, TX 972-599-2130 805-987-4880 714-546-4880 858-385-2655 650-969-6060 MONTREAL OTTAWA TORONTO VANCOUVER 514-337-6769 613-599-8787 905-238-9548 604-276-8735 WESTMINSTER, CO 303-426-0890 MARLBORO, MA 508-485-7204 DOYLESTOWN, PA 267-880-6321 OLATHE, KS 913-829-2800 RATHSBURG ASSOCIATES RATHSBURG ASSOCIATES EASTERN WESTERN 248-615-4000 317-818-7055 PLANO, TX 972-599-2130 MARLBORO, MA 508-485-7204 DOYLESTOWN, PA 267-880-6321 MARLBORO, MA 508-485-7204 MUNDELEIN, IL 847-573-6504 NOVI, MI 248-615-4000 BLOOMINGTON, MN 952-893-1400 HUNTSVILLE, AL 800-242-5876 ST. LOUIS, MO 636-946-1001 KIRKLAND, WA 425-893-8400 LOUISIANA MAINE CONTI-YOUNGER ASSOCIATES MARYLAND CONTI-YOUNGER ASSOCIATES TE CONNECTIVITY DOYLESTOWN, PA RATHSBURG ASSOCIATES MINNESOTA 267-880-6321 FLORIDA RATHSBURG ASSOCIATES MISSISSIPPI CASSELBERRY, FL 407-774-9100 GEORGIA CARTWRIGHT & BEAN, INC. MISSOURI NORCROSS, GA 800-242-5876 ILLINOIS RATHSBURG ASSOCIATES (NORTH) RATHSBURG ASSOCIATES (SOUTH) 952-893-1400 MICHIGAN DISTRICT OF COLUMBIA CARTWRIGHT & BEAN, INC. BLOOMINGTON, MN MEXICO DELAWARE CBX ELECTRONICS 317-818-7055 MASSACHUSETTS CONNECTICUT ASTROREP MID-ATLANTIC, INC. RATHSBURG ASSOCIATES ASTROREP MID-ATLANTIC, INC. COLORADO ASTROREP MID-ATLANTIC, INC. RATHSBURG ASSOCIATES ELECTRA REPS CANADA CONTI-YOUNGER ASSOCIATES CARMEL, IN KENTUCKY LUSCOMBE ENGINEERING (SOUTH) CAMARILLO, CA LUSCOMBE ENGINEERING (SOUTH) COSTA MESA, CA LUSCOMBE ENGINEERING (SOUTH) SAN DIEGO, CA STRAUBE ASSOCIATES (NORTH) MOUNTAIN VIEW, CA STRAUBE ASSOCIATES ROCKY MOUNTAINS, INC. RATHSBURG ASSOCIATES KANSAS CALIFORNIA WEISS COMPANY WEISS COMPANY WEISS COMPANY WEISS COMPANY 425-893-8400 IOWA ARKANSAS ELECTRA REPS KIRKLAND, WA INDIANA ARIZONA LUSCOMBE ENGINEERING HALBAR-RTS, INC. RATHSBURG ASSOCIATES MONTANA ITASCA, IL ST. LOUIS, MO 630-625-5100 636-946-1001 HALBAR-RTS, INC. 286 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide North American Sales Representatives NEBRASKA SOUTH CAROLINA RATHSBURG ASSOCIATES OLATHE, KS 913-829-2800 NEVADA 650-969-6060 602-678-1955 NEW HAMPSHIRE CONTI-YOUNGER ASSOCIATES MARLBORO, MA 508-485-7204 NEW JERSEY LUSCOMBE ENGINEERING BLOOMINGTON, MN 952-893-1400 NORCROSS, GA HUNTSVILLE, AL 800-242-5876 800-242-5876 PLANO, TX AUSTIN HOUSTON EL PASO, TX 972-599-2130 512-249-1101 281-516-1122 602-678-1955 WESTMINSTER, CO 303-426-0890 MARLBORO, MA 508-485-7204 DOYLESTOWN, PA 267-880-6321 KIRKLAND, WA 425-893-8400 COLUMBUS, OH 248-615-4000 MUSKEGO, WI HARTFORD, WI 262-679-8250 262-670-6513 WESTMINSTER, CO 303-426-0890 TENNESSEE CARTWRIGHT & BEAN (EAST) CARTWRIGHT & BEAN (WEST) 267-880-6321 631-422-2500 ELECTRA REPS ELECTRA REPS ELECTRA REPS LUSCOMBE ENGINEERING (EL PASO) PHOENIX, AZ 602-678-1955 UTAH STRAUBE ASSOCIATES ROCKY MOUNTAINS, INC. NEW YORK EMPIRE TECHNICAL ASSOCIATES (UPSTATE) ASTROREP INC. SKANEATELES, NY BABYLON, NY 315-685-5703 631-422-2500 NORTH CAROLINA CARTWRIGHT & BEAN, INC. (WEST) CARTWRIGHT & BEAN, INC. (EAST) VERMONT CONTI-YOUNGER ASSOCIATES VIRGINIA CHARLOTTE, NC RALEIGH, NC 800-242-5876 800-242-5876 BLOOMINGTON, MN 952-893-1400 COLUMBUS, OH 248-615-4000 PLANO, TX 972-599-2130 NORTH DAKOTA ASTROREP MID-ATLANTIC, INC. WASHINGTON HALBAR-RTS, INC. OHIO WEST VIRGINIA RATHSBURG ASSOCIATES OKLAHOMA OREGON HALBAR-RTS, INC. RATHSBURG ASSOCIATES DOYLESTOWN, PA BABYLON, NY NEW MEXICO ELECTRA REPS 800-242-5876 TEXAS ASTROREP MID-ATLANTIC, INC. (SOUTH) ASTROREP, INC. (NORTH) RATHSBURG ASSOCIATES CHARLOTTE, NC SOUTH DAKOTA STRAUBE ASSOCIATES MOUNTAIN VIEW, CA LUSCOMBE ENGINEERING (LAS VEGAS) PHOENIX, AZ RATHSBURG ASSOCIATES CARTWRIGHT & BEAN, INC. WISCONSIN RATHSBURG ASSOCIATES RATHSBURG ASSOCIATES WYOMING BEAVERTON, OR 503-624-5741 PENNSYLVANIA ASTROREP MID-ATLANTIC, INC. (EAST) DOYLESTOWN, PA RATHSBURG ASSOCIATES (WEST) PITTSBURGH, PA STRAUBE ASSOCIATES ROCKY MOUNTAINS, INC. 267-880-6321 248-615-4000 PUERTO RICO CBX ELECTRONICS ALTAMONTE SPRINGS, FL 407-774-9100 MARLBORO, MA 508-485-7204 RHODE ISLAND CONTI-YOUNGER ASSOCIATES 287 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Authorized Corcom Product Distributors and Resellers All American www.allamerican.com 1-800-573-ASAP Hammond Electronics www.hammondelec.com 1-800-929-2677 Allied Electronics, Inc. www.alliedelec.com 1-800-433-5700 Heilind Electronics www.heilind.com 1-800-400-7041 Arrow Electronics www.arrow.com 1-800-777-2776 Marsh Electronics www.marshelectronics.com 1-800-236-8327 Avnet www.avnet.com US: 1-800-332-8638 Master Distributors www.masterdistributors.com 1-888-473-5297 Carlton Bates Company www.carlton-bates.com 1-866-600-6040 Mouser Electronics www.mouser.com 1-800-346-6873 Digi-Key Corporation www.digikey.com 1-800-344-4539 Newark Electronics www.newark.com 1-800-463-9275 Electro Sonic www.e-sonic.com 1-800-567-6642 Norvell Electronics www.norvell.com 1-800-893-0593 Future Electronics www.futureelectronics.com US & Canada: 1-800-FUTURE-1 (388-8731) Sager Electronics www.sager.com 1-800-SAGER-800 Genie Group www.geniegroup.com 1-615-771-9412 Simcona Electronics www.simcona.com US: 1-800-274-6266 Gopher Electronics www.gopherelectronics.com 1-800-592-9519 TTI Inc. www.ttiinc.com 1-800-CALL-TTI Canada: 1-519-652-1130 288 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. For email, phone or live chat, please go to te.com/help corcom.com Catalog: 1654001 Issue Date: 06.2011 Corcom Product Guide Global Contacts Americas Argentina - Buenos Aires Canada - Toronto Phone: +54-11-4733-2200 Fax: +54-11-4733-2211 Phone: +905-475-6222 Fax: +905-474-5520 Product Information Center: Phone: +905-470-4425 Fax: +905-474-5525 Brasil - Sao Paulo Phone: +55-11-2103-6000 Fax: +55-11-2103-6030 Chile - Santiago Phone: +56-2-345-0361 Fax: +56-2-223-1477 Colombia - Bogota Phone: +57-1-319-8959 Fax: +57-1-319-8960 Mexico - Mexico City Phone: +52-55-1106-0800 +01-800-733-8926 Fax: +52-55-1106-0901 United States For Latin/South American Countries not shown Phone: +54-11-4733-2015 Fax: +54-11-4733-2083 Harrisburg, PA Phone: +1-717-564-0100 Fax: +1-717-986-7575 Product Information Center: Phone: +1-800-522-6752 Fax: +1-717-986-7575 Mundelein, IL Phone: +1-847-680-7400 Fax: +1-847-680-8169 Asia/Pacific Australia - Sydney Phone: +61-2-9554-2600 Fax: +61-2-9502-2556 Product Information Center: Phone: +61-2-9840-8200 Fax: +61-2-9634-6188 Japan - Kawasaki, Kanagawa India - Bangalore Phone: +91-80-285-40800 Fax: +91-80-285-40820 Korea - Seoul Phone: +82-2-3415-4500 Fax: +82-2-3486-3810 Indonesia - Jakarta Malaysia - Selangor Phone: +65-6482-0311 Fax: +65-6482-1012 Phone: +60-3-7805-3055 Fax: +60-3-7805-3066 Phone: +81-44-844-8111 Fax: +81-44-812-3207 Product Information Center: Phone: +81-44-844-8013 Fax: +81-44-812-3200 New Zealand - Auckland Phone: +64-9-634-4580 Fax: +64-9-634-4586 Singapore - Singapore Phone: +65-6482-0311 Fax: +65-6482-1012 Philippines - Makati City Phone: +632-848-0171 Fax: +632-867-8661 Taiwan - Taipei Phone: +886-2-8768-2788 Fax: +886-2-8768-2268 People's Republic of China Thailand - Bangkok Phone: +66-2-955-0500 Fax: +66-2-955-0505 Hong Kong Phone: +852-2735-1628 Fax: +852-2735-0243 Vietnam - Ho Chi Minh City Shanghai Phone: +86-21-2407-1588 Fax: +86-21-2407-1599 Phone: +84-8-930-5546 Fax: +84-8-930-3443 Lithuania and Latvia Lithuania - Vilnius Slovenia - Ljubljana Europe/Middle East/Africa Austria - Vienna Phone: +43-1-905-60-0 Fax: +43-1-905-60-1333 Product Information Center: Phone: +43-1-905-60-1228 Fax: +43-1-905-60-1333 Belarus - Minsk Phone: +375 17 237 47 94 Fax: +375 17 237 47 94 Belgium - Kessel-Lo Phone: +32-16-352-300 Fax: +32-16-352-355 Bulgaria - Sofia Phone: +359-2-971-2152 Fax: +359-2-971-2153 Czech Republic and Slovakia Czech Republic - Kurim Phone: +420-541-162-111 Fax: +420-541-162-223 Product Information Center: Phone: +420-541-162-113 Fax: +420-541-162-104 France - Cergy-Pontoise Cedex Phone: +33-1-3420-8888 Fax: +33-1-3420-8600 Product Information Center: Phone: +33-1-3420-8686 Fax: +33-1-3420-8623 France Export Divisions - Cergy-Pontoise Cedex Phone: +33-1-3420-8804 Fax: +33-1-3420-8699 Germany - Bensheim Phone: +49-6251-133-0 Fax: +49-6251-133-1600 Product Information Center: Phone: +49-6251-133-1999 Fax: +49-6251-133-1988 Greece - Athens Phone: +30-210-9370396/397 Fax: +30-210-9370-655 Phone: +45-43-48-04-00 Fax: +45-43-44-14-14 Hungary - Budapest Phone: +36-1-289-1000 Fax: +36-1-289-1010 Product Information Center: Phone: +36-1-289-1016 Fax: +36-1-289-1017 Egypt - Cairo Phone: +202-419-2334 Fax: +202-417-7647 Ireland - Dublin Phone: +353-1-866-5612 Fax: +353-1-866-5714 Estonia - Tartu Phone: +372-5138-274 Fax: +372-7400-779 Israel - Petach-Tikva Phone: +972-3-929-0999 Fax: +972-3-919-1088 Finland - Helsinki Italy - Collegno (Torino) Phone: +358-95-12-34-20 Fax: +358-95-12-34-250 Phone: +39-011-4012-111 Fax: +39-011-4031-116 Product Information Center: Phone: +39-011-4012-632 Fax: +39-011-40-287-632 Denmark - Glostrup Phone: +370-5-213-1402 Fax: +370-5-213-1403 Product Information Center: Phone: +370-5-211-3016 Fax: +370-5-213-1403 's-Hertogenbosch Phone: +31-73-6246-246 Fax: +31-73-6212-365 Product Information Center: Phone: +31-73-6246-999 Fax: +31-73-6246-998 Norway - Nesbru Sweden - Upplands Vasby Phone: +46-8-50-72-50-00 Fax: +46-8-50-72-50-01 Switzerland - Steinach Turkey - Istanbul Poland - Warsaw Phone: +48-22-4576-700 Fax: +48-22-4576-720 Product Information Center: Phone: +48-22-4576-704 Fax: +48-22-4576-720 Romania - Bucharest Phone: +40-21-311-3479/3596 Fax: +40-21-312-0574 Russia - Moscow Phone: +7-495-790-7902 Fax: +7-495-721-1893 Product Information Center: Phone: +7-495-790-7902-404 Fax: +7-495-790-7902-401 Dimensions are in inches and millimeters unless otherwise specified. Values in italics are metric equivalents. Dimensions are shown for reference purposes only. Specifications subject to change. Phone: +34-93-291-0330 Fax: +34-93-201-7879 Phone: +41-71-447-0447 Fax: +41-71-447-0444 Phone: +47-66-77-88-50 Fax: +47-66-77-88-55 Phone: +7-812-718-8192 Fax: +7-812-718-8193 South Africa - Port Elizabeth Phone: +27-41-503-4500 Fax: +27-41-581-0440 Spain - Barcelona Netherlands - Russia - St. Petersburg Phone: +386-1561-3270 Fax: +386-1561-3240 Phone: +90-212-281-8181/2/3 +90-212-2825130/5430 Fax: +90-212-281-8184 Ukraine - Kiev Phone: +380-44-206-2265 Fax: +380-44-206-2264 Product Information Center: Phone: +380-44-206-2265 Fax: +380-44-206-2264 United Kingdom - Stanmore, Middlesex Phone: +44-8706-080208 Fax: +44-208-954-6234 Product Information Center: Freephone (UK only): +0800-267-666 Phone: +44-8706-080208 Fax: +44-208-420-8095 For email, phone or live chat, please go to te.com/help corcom.com FOR MORE INFORMATION te.com/industry/commercial-building-technology corcom.com TE Technical Support Center Internet: te.com/help USA: +1 (800) 522-6752 Canada: +1 (905) 475-6222 Mexico +52 (0) 55-1106-0800 Latin/S. America: +54 (0) 11-4733-2200 Germany: +49 (0) 6251-133-1999 UK: +44 (0) 800-267666 France: +33 (0) 1-3420-8686 Netherlands: +31 (0) 73-6246-999 China: +86 (0) 400-820-6015 Part numbers in this brochure are RoHS Compliant*, unless marked otherwise. *as defined www.te.com/leadfree te.com corcom.com (c) 2011 Tyco Electronics Corporation, a TE Connectivity Ltd. company. All Rights Reserved. 1654001 CIS JG 06/2011 Corcom, TE Connectivity, TE connectivity (logo) and TE (logo) are trademarks. Other logos, product and/or company names might be trademarks of their respective owners. Mouser Electronics Authorized Distributor Click to View Pricing, Inventory, Delivery & Lifecycle Information: TE Connectivity: 12FCD10B