CTS1, CTS13, 749DX
Vishay Sprague Hermetically Sealed, Axial-Lead
to CECC Specifications
www.vishay.com For technical questions, contact: tantalum@vishay.com Document Number: 42073
69 Revision: 02-Nov-09
PERFORMANCE CHARACTERISTICS
1. Operating temperature:
- 55 °C to + 85 °C with rated DC voltage UR applied,
+ 85 °C to + 125 °C with linear voltage derating
to category voltage UC (only for types CTS1, 749DX).
2. Capacitance and tolerance:
Capacitance measured at 100 Hz and + 25 °C shall be
within the specified tolerance limits of the nominal rating.
Capacitance measurement shall be made by means of a
polarized capacitance bridge. The polarizing voltage shall
be of 2.2 V. The maximum voltage applied during
measurements shall be 1.0 Vrms at 100 Hz and + 25 °C.
3. Reverse voltage:
These capacitors are capable of withstanding peak
voltage in the reverse direction equal to: 15 % of the rated
DC voltage at + 25 °C, 5 % of the rated DC voltage at
+ 85 °C.
4. Surge voltage:
Table 1
Capacitors shall withstand the surge voltage applied in
series with a 1000 W resistor, at the rate of 1.5 min on,
5.5 min off, for 1000 successive test cycles at + 85 °C or
at + 125 °C. After test, dissipation factor and leakage
current shall meet the initial requirements at + 25 °C (see
below), capacitance change shall not exceed ± 10 % of
initial value at + 25 °C.
5. Leakage current:
Rated voltage UR shall be applied to capacitors during five
minutes with a resistor of 1000 Ω in series with each
capacitor, before making DC leakage current
measurements. The leakage current shall not exceed the
following limits:
Table 2
6. Dissipation factor:
The dissipation factor, when measured at 100 Hz, shall not
exceed the values below:
Table 3
7. Stability at low and high temperature:
Capacitance change with temperature shall not exceed
the limits of the following table, leakage current and
dissipation factor shall be within the limits specified in
Tables 2 and 3.
Table 4
8. Impedance:
The impedance measured at 100 kHz and 25 °C shall not
exceed the following values:
Table 5
9. Life test:
After 2000 h at + 85 °C with rated DC voltage applied,
or after 2000 h at + 125 °C with category DC voltage
applied (for types CTS1, 749DX only) capacitors shall
meet the requirements in table 6.
Table 6
PRODUCT
TYPE
SURGE VOLTAGE
AT + 85 °C
SURGE VOLTAGE
AT + 125 °C
CTS13 1.30 UR -
749DX/CTS1 1.30 UR 1.30 UC
TEMPERATURE CTS1/CTS13/749DX
+ 25 °C 0.01 CR x UR or
1 µA whichever is greater
+ 85 °C 0.1 CR x UR or
10 µA whichever is greater
+ 125 °C 0.125 CR x UR or
12.5 µA whichever is greater
TEMP. CTS1/CTS13 749DX
CRUR ≤ 1900 CRUR > 1900 CR ≤ 100 CR > 100
- 55 °C 9 % 11 % 8 % 10 %
+ 25 °C 6 % 8 % 6 % 8 %
+ 85 °C 9 % 11 % - -
+ 125 °C (1) 12 % 14 % 10 % 11 %
Note (1) Not applicable for CTS13
TEMPERATURE CTS1/CTS13/749DX
- 55 °C - 10 %
+ 85 °C + 12 %
+ 125 °C (2) + 15 %
Note (2) Not applicable for CTS13
CASE CODE Z (Ω) (3)
A10
B5
C2
D1
Note (3) Not applicable for CR ≤ 0.68 µF
PRODUCT
TYPE
CAPACITANCE
CHANGE
DISSIPATION
FACTOR
DC LEAKAGE
CURRENT
CTS1
CTS13
749DX
Within
± 10 % of
initial value
at + 25 °C
Within
initial
requirement
at + 25 °C
Within 125 %
of initial
requirements
at + 25 °C