cui.com
date 02/25/2015 │ page 2 of 7CUI Inc │ SERIES: VSK-S25-T │ DESCRIPTION: AC-DC POWER SUPPLY
INPUT
parameter conditions/description min typ max units
voltage 85
120
264
370
Vac
Vdc
frequency 47 63 Hz
current at 115 Vac
at 230 Vac
600
340
mA
mA
inrush current at 115 Vac
at 230 Vac
16
30
A
A
leakage current at 230 Vac, 50 Hz (RMS) 0.3 mA
input fuse 3.15 A/250 V, slow-blow type (included on chassis)
OUTPUT
parameter conditions/description min typ max units
capacitive load
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
12,240
5,600
5,400
2,400
1,440
800
μF
μF
μF
μF
μF
μF
line regulation at full load ±0.5 %
load regulation at 10~100% load ±1 %
voltage set accuracy ±2 %
adjustability ±10 %
hold-up time at 115 Vac
at 230 Vac
15
80
ms
ms
switching frequency 65 kHz
temperature coefcient ±0.02 %/°C
PROTECTIONS
parameter conditions/description min typ max units
over current protection auto restart 110 %
short circuit protection continuous, auto restart
over voltage protection
5 Vdc output model
9 Vdc output model
12 Vdc output model
15 Vdc output model
24 Vdc output model
48 Vdc output model
7.5
12
20
20
30
60
Vdc
Vdc
Vdc
Vdc
Vdc
Vdc
SAFETY & COMPLIANCE
parameter conditions/description min typ max units
isolation voltage input to output for 1 minute 3,000 Vac
safety approvals UL60950-1, CE
safety class class I
conducted emissions CISPR22/EN55022, Class B
radiated emissions CISPR22/EN55022, Class B
ESD IEC/EN61000-4-2 Class B, contact ±6 kV/air ±8 kV
radiated immunity IEC/EN61000-4-3 Class A, 10V/m
EFT/burst IEC/EN61000-4-4 Class B, ±2 kV
IEC/EN61000-4-4 Class B, ±4 kV (external circuit required, see gure 2)