X9241A Quad Digital Controlled Potentionmeters (XDCPTM) Data Sheet August 17, 2015 FN8164.7 Non-Volatile/Low Power/2-Wire/64 Taps Features The X9241A integrates four digitally controlled potentiometers (XDCP) on a monolithic CMOS integrated microcircuit. * Four potentiometers in one package * 2-wire serial interface The digitally controlled potentiometer is implemented using 63 resistive elements in a series array. Between each element are tap points connected to the wiper terminal through switches. The position of the wiper on the array is controlled by the user through the 2-wire bus interface. Each potentiometer has associated with it a volatile Wiper Counter Register (WCR) and 4 nonvolatile Data Registers (DR0:DR3) that can be directly written to and read by the user. The contents of the WCR controls the position of the wiper on the resistor array through the switches. Power up recalls the contents of DR0 to the WCR. The XDCP can be used as a three-terminal potentiometer or as a two-terminal variable resistor in a wide variety of applications including control, parameter adjustments, and signal processing. * Register oriented format - Direct read/write/transfer of wiper positions - Store as many as four positions per potentiometer * Terminal Voltages: +5V, -3.0V * Cascade resistor arrays * Low power CMOS * High Reliability - Endurance-100,000 data changes per bit per register - Register data retention-100 years * 16-bytes of nonvolatile memory * 3 resistor array values - 2k10k50kor combination - Cascadable for values of 4kto 200k * Resolution: 64 taps each pot * 20 Ld plastic DIP, 20 Ld TSSOP and 20 Ld SOIC packages * Pb-free available (RoHS compliant) Block Diagram VCC VSS R0 R1 R2 R3 VH0/RH0 WIPER COUNTER REGISTER (WCR) VL0/RL0 R0 R1 R2 R3 WIPER COUNTER REGISTER (WCR) REGISTER ARRAY POT 2 VW0/RW0 VH2/ RH2 VL2/RL2 VW2/RW2 SCL SDA A0 A1 INTERFACE AND CONTROL CIRCUITRY 8 A2 A3 DATA VH1/RH1 R0 R1 R2 R3 1 WIPER COUNTER REGISTER (WCR) REGISTER ARRAY POT 1 VL1/RL1 VW1/RW1 VH3/RH3 R0 R1 R2 R3 WIPER COUNTER REGISTER (WCR) REGISTER ARRAY POT 3 VL3/RL3 VW3/RW3 CAUTION: These devices are sensitive to electrostatic discharge; follow proper IC Handling Procedures. 1-888-INTERSIL or 1-888-468-3774 | Copyright Intersil Americas LLC 2005, 2006, 2007, 2015. All Rights Reserved Intersil (and design) is a trademark owned by Intersil Corporation or one of its subsidiaries. All other trademarks mentioned are the property of their respective owners. X9241A Ordering Information PART NUMBER PART MARKING VCC LIMITS (V) POTENTIOMETER ORGANIZATION (k) TEMP RANGE (C) 5 10% 2/10/50 0 to +70 20 Ld PDIP*** -40 to +85 20 Ld PDIP*** PACKAGE (RoHS Compliant) X9241AMPZ (Note) (No longer available, recommended replacement: X9241AMSZT1) X9241AMPZ X9241AMPIZ (Note) (No longer available, recommended replacement: X9241AMSZT1) X9241AMPIZ X9241AMSZ* (Note) X9241AMS Z 0 to +70 20 Ld SOIC X9241AMSIZ* (Note) X9241AMSI Z -40 to +85 20 Ld SOIC X9241AMVZ (Note) X9241AM VZ 0 to +70 20 Ld TSSOP X9241AMVIZ* (Note) X9241AM VIZ -40 to +85 20 Ld TSSOP Pot 0 = 2k Pot 1 = 10k Pot 2 = 10k Pot 3 = 50k X9241AWPIZ (Note) X9241AWPIZ X9241AWSZ* (Note) X9241AWS Z X9241AWSIZ* (Note) X9241AWSI Z X9241AWVZ* (Note) X9241AW VZ X9241AWVIZ* (Note) X9241AW VIZ X9241AYPZ (Note) (No longer available, recommended replacement: X9241AYSIZ) X9241AYPZ X9241AYSZ* (Note) X9241AYS Z X9241AYSIZ* (Note) X9241AYSI Z X9241AYVZ (Note) (No longer available, recommended replacement: X9241AYVIZ) X9241AY VZ 0 to +70 20 Ld PDIP Pot 0 = 10k 0 to +70 20 Ld SOIC Pot 1 = 10k -40 to +85 20 Ld SOIC 10 Pot 2 = 10k Pot 3 = 10k 2 0 to +70 20 Ld TSSOP -40 to +85 20 Ld TSSOP 0 to +70 20 Ld PDIP*** 0 to +70 20 Ld SOIC -40 to +85 20 Ld SOIC Pot 0 = 2k Pot 1 = 2k X9241AYVIZ* (Note) X9241AY VIZ X9241AUPZ (Note) X9241AUPZ X9241AUPIZ (Note) Pot 2 = 2k Pot 3 = 2k 0 to +70 20 Ld TSSOP -40 to +85 20 Ld TSSOP 50 0 to +70 20 Ld PDIP*** X9241AUPIZ Pot 0 = 50k -40 to +85 20 Ld PDIP*** X9241AUSZ* (Note) X9241AUS Z Pot 1 = 50k 0 to +70 20 Ld SOIC X9241AUSIZ* (Note) X9241AUSI Z Pot 2 = 50k -40 to +85 20 Ld SOIC X9241AUVZ* (Note) (No longer available, recommended replacement: X9241AUSZT1) X9241AU VZ X9241AUVIZ* (Note) X9241AU VIZ 5 10% Pot 3 = 50k 0 to +70 20 Ld TSSOP -40 to +85 20 Ld TSSOP *Add "T1" suffix for tape and reel. ***Pb-free PDIPs can be used for through hole wave solder processing only. They are not intended for use in Reflow solder processing applications. NOTE: These Intersil Pb-free plastic packaged products employ special Pb-free material sets; molding compounds/die attach materials and 100% matte tin plate PLUS ANNEAL - e3 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering operations. Intersil Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD-020. 2 FN8164.7 August 17, 2015 X9241A Pin Descriptions Pin Names Host Interface Pins SYMBOL DESCRIPTION Serial Clock (SCL) VH0/RH0 to VH3/RH3, VL0/RL0 to VL3/RL3 Potentiometer Pins (terminal equivalent) The SCL input is used to clock data into and out of the X9241A. VW0/RW0 to VW3/RW3 Potentiometer Pins (wiper equivalent) Serial Data (SDA) Principles of Operation SDA is a bidirectional pin used to transfer data into and out of the device. It is an open drain output and may be wireORed with any number of open drain or open collector outputs. An open drain output requires the use of a pull-up resistor. For selecting typical values, refer to the guidelines for calculating typical values on the bus pull-up resistors graph. The X9241A is a highly integrated microcircuit incorporating four resistor arrays, their associated registers and counters and the serial interface logic providing direct communication between the host and the XDCP potentiometers. Address The Address inputs are used to set the least significant 4-bits of the 8-bit slave address. A match in the slave address serial data stream must be made with the Address input in order to initiate communication with the X9241A. Potentiometer Pins VH/RH(VH0/RH0 TO VH3/RH3), VL/RL (VL0/RL0 TO VL3/RL3) Serial Interface The X9241A supports a bidirectional bus oriented protocol. The protocol defines any device that sends data onto the bus as a transmitter and the receiving device as the receiver. The device controlling the transfer is a master and the device being controlled is the slave. The master will always initiate data transfers and provide the clock for both transmit and receive operations. Therefore, the X9241A will be considered a slave device in all applications. Clock and Data Conventions The RH and RL inputs are equivalent to the terminal connections on either end of a mechanical potentiometer. Data states on the SDA line can change only during SCL LOW periods (tLOW). SDA state changes during SCL HIGH are reserved for indicating start and stop conditions. VW/RW (VW0/RW0 TO VW3/RW3) Start Condition The wiper outputs are equivalent to the wiper output of a mechanical potentiometer. Pinout X9241A (20 LD DIP, SOIC, TSSOP) TOP VIEW Stop Condition VW0/RW0 1 20 VL0/RL0 2 19 VW3/RW3 VH0/RH0 3 18 VL3/RL3 A0 4 17 VH3/RH3 A2 5 16 A1 VW1/RW1 6 15 A3 VL1/RL1 7 14 SCL VH1/RH1 8 13 VW2/RW2 SDA 9 12 VL2/RL2 VSS 10 11 VH2/RH2 X9241A VCC Pin Names SYMBOL SCL SDA A0 to A3 DESCRIPTION Serial Clock Serial Data All commands to the X9241A are preceded by the start condition, which is a HIGH to LOW transition of SDA while SCL is HIGH (tHIGH). The X9241A continuously monitors the SDA and SCL lines for the start condition and will not respond to any command until this condition is met. All communications must be terminated by a stop condition, which is a LOW to HIGH transition of SDA while SCL is HIGH. Acknowledge Acknowledge is a software convention used to provide a positive handshake between the master and slave devices on the bus to indicate the successful receipt of data. The transmitting device, either the master or the slave, will release the SDA bus after transmitting 8-bits. The master generates a ninth clock cycle and during this period the receiver pulls the SDA line LOW to acknowledge that it successfully received the 8-bits of data. See Figure 7. The X9241A will respond with an acknowledge after recognition of a start condition and its slave address and once again after successful receipt of the command byte. If the command is followed by a data byte the X9241A will respond with a final acknowledge. Address 3 FN8164.7 August 17, 2015 X9241A Array Description Flow 1. ACK Polling Sequence The X9241A is comprised of four resistor arrays. Each array contains 63 discrete resistive segments that are connected in series. The physical ends of each array are equivalent to the fixed terminals of a mechanical potentiometer (VH/RH and VL/RL inputs). At both ends of each array and between each resistor segment is a FET switch connected to the wiper (VW/RW) output. Within each individual array only one switch may be turned on at a time. These switches are controlled by the Wiper Counter Register (WCR). The 6 least significant bits of the WCR are decoded to select, and enable, 1 of 64 switches. The WCR may be written directly, or it can be changed by transferring the contents of one of four associated Data Registers into the WCR. These Data Registers and the WCR can be read and written by the host system. NONVOLATILE WRITE COMMAND COMPLETED ENTER ACK POLLING ISSUE START ISSUE SLAVE ADDRESS ACK RETURNED? ISSUE STOP NO YES NO FURTHER OPERATION? Device Addressing Following a start condition the master must output the address of the slave it is accessing. The most significant 4-bits of the slave address are the device type identifier (refer to Figure 1). For the X9241A, this is fixed as 0101[B]. YES ISSUE INSTRUCTION ISSUE STOP PROCEED PROCEED DEVICE TYPE IDENTIFIER 0 1 0 1 A3 A2 A1 A0 Instruction Structure DEVICE ADDRESS FIGURE 1. SLAVE ADDRESS The next 4-bits of the slave address are the device address. The physical device address is defined by the state of the A0 to A3 inputs. The X9241A compares the serial data stream with the address input state; a successful compare of all 4 address bits is required for the X9241A to respond with an acknowledge. The next byte sent to the X9241A contains the instruction and register pointer information. The 4 most significant bits are the instruction. The next 4-bits point to one of four pots and when applicable they point to one of four associated registers. The format is in Figure 2. POTENTIOMETER SELECT I3 I2 I1 I0 P1 P0 R1 R0 Acknowledge Polling The disabling of the inputs, during the internal nonvolatile write operation, can be used to take advantage of the typical 5ms EEPROM write cycle time. Once the stop condition is issued to indicate the end of the nonvolatile write command, the X9241A initiates the internal write cycle. ACK polling can be initiated immediately. This involves issuing the start condition followed by the device slave address. If the X9241A is still busy with the write operation, no ACK will be returned. If the X9241A has completed the write operation, an ACK will be returned and the master can then proceed with the next operation. 4 INSTRUCTIONS REGISTER SELECT FIGURE 2. INSTRUCTION BYTE FORMAT The 4 high order bits define the instruction. The next 2-bits (P1 and P0) select which one of the four potentiometers is to be affected by the instruction. The last 2-bits (R1 and R0) select one of the four registers that are to be acted upon when a register oriented instruction is issued. Four of the nine instructions end with the transmission of the instruction byte. The basic sequence is illustrated in Figure 3. These two-byte instructions exchange data between the WCR and one of the data registers. A transfer from a Data Register to a WCR is essentially a write to a static RAM. The response FN8164.7 August 17, 2015 X9241A Register, write a new value to the selected Data Register. The sequence of operations is shown in Figure 4. of the wiper to this action will be delayed tSTPWV. A transfer from WCR current wiper position to a Data Register is a write to nonvolatile memory and takes a minimum of tWR to complete. The transfer can occur between one of the four potentiometers and one of its associated registers; or it may occur globally, wherein the transfer occurs between all four of the potentiometers and one of their associated registers. The Increment/Decrement command is different from the other commands. Once the command is issued and the X9241A has responded with an acknowledge, the master can clock the selected wiper up and/or down in one segment steps; thereby, providing a fine tuning capability to the host. For each SCL clock pulse (tHIGH) while SDA is HIGH, the selected wiper will move one resistor segment towards the VH/RH terminal. Similarly, for each SCL clock pulse while SDA is LOW, the selected wiper will move one resistor segment towards the VL/RL terminal. A detailed illustration of the sequence and timing for this operation is shown in Figures 5 and 6 respectively. Four instructions require a three-byte sequence to complete. These instructions transfer data between the host and the X9241A; either between the host and one of the Data Registers or directly between the host and the WCR. These instructions are: Read WCR, read the current wiper position of the selected pot; Write WCR, change current wiper position of the selected pot; Read Data Register, read the contents of the selected nonvolatile register; Write Data SCL SDA S T A R T 0 1 0 1 A3 A2 A1 A0 A C K I3 I2 I1 I0 P1 P0 R1 A C K R0 S T O P FIGURE 3. TWO-BYTE INSTRUCTION SEQUENCE SCL SDA S T A R T 0 1 0 1 A3 A2 A1 A0 A C K I3 I2 I1 I0 P1 P0 R1 R0 A C K CM DW D5 D4 D3 D2 D1 D0 A C K S T O P FIGURE 4. THREE-BYTE INSTRUCTION SEQUENCE SCL SDA S T A R T 0 1 0 1 A3 A2 A1 A0 A C K I3 I2 I1 I0 P1 P0 X X R1 R0 A C K I N C 1 I N C 2 I N C n D E C 1 D E C n S T O P FIGURE 5. INCREMENT/DECREMENT INSTRUCTION SEQUENCE 5 FN8164.7 August 17, 2015 X9241A INC/DEC CMD ISSUED tCLWV SCL SDA VOLTAGE OUT VW/RW FIGURE 6. INCREMENT/DECREMENT TIMING LIMITS TABLE 1. INSTRUCTION SET INSTRUCTION FORMAT INSTRUCTION I3 I2 I1 I0 R1 R0 OPERATION Read WCR 1 0 0 1 X X Read the contents of the Wiper Counter Register pointed to by P1 to P0 Write WCR 1 0 1 1/0 X X Write new value to the Wiper Counter Register pointed to by P1 to P0 Read Data Register 1 0 1/0 1/0 1/0 1/0 Read the contents of the Register pointed to by P1 to P0 and R1 to R0 Write Data Register 1 0 1/0 1/0 1/0 1/0 Write new value to the Register pointed to by P1 to P0 and R1 to R0 XFR Data Register to WCR 0 1 1/0 1/0 1/0 1/0 Transfer the contents of the Register pointed to by P1 to P0 and R1 to R0 to its associated WCR 1 1 0 1/0 1/0 1/0 1/0 Transfer the contents of the WCR pointed to by P1 to P0 to the Register pointed to by R1 to R0 0 0 0 1 X X 1/0 1/0 Transfer the contents of the Data Registers pointed to by R1 to R0 of all four pots to their respective WCR Global XFR WCR to Data Register 1 0 0 0 X X 1/0 1/0 Transfer the contents of all WCRs to their respective data Registers pointed to by R1 to R0 of all four pots Increment/ Decrement Wiper 0 0 1 0 1/0 1/0 X X P1 P0 1/0 1/0 0 1/0 1 1 1 0 1 1 XFR WCR to Data Register 1 Global XFR Data Register to WCR (Note 1) (Note 2) Enable Increment/decrement of the WCR pointed to by P1 to P0 NOTES: 1. 1/0 = data is one or zero 2. X = Not applicable or don't care; that is, a data register is not involved in the operation and need not be addressed (typical). 6 FN8164.7 August 17, 2015 X9241A SCL FROM MASTER 1 8 9 DATA OUTPUT FROM TRANSMITTER DATA OUTPUT FROM RECEIVER STAR T ACKNOWLEDGE FIGURE 7. ACKNOWLEDGE RESPONSE FROM RECEIVER 7 FN8164.7 August 17, 2015 X9241A The WCR is a volatile register; that is, its contents are lost when the X9241A is powered-down. Although the register is automatically loaded with the value in DR0 upon power-up, it should be noted this may be different from the value present at power-down. Detailed Operation All four XDCP potentiometers share the serial interface and share a common architecture. Each potentiometer is comprised of a resistor array, a Wiper Counter Register and four Data Registers. A detailed discussion of the register organization and array operation follows. Data Registers Each potentiometer has four nonvolatile Data Registers. These can be read or written directly by the host and data can be transferred between any of the four Data Registers and the WCR. It should be noted all operations changing data in one of these registers is a nonvolatile operation and will take a maximum of 10ms. Wiper Counter Register The X9241A contains four volatile Wiper Counter Registers (WCR), one for each XDCP potentiometer. The WCR can be envisioned as a 6-bit parallel and serial load counter with its outputs decoded to select one of sixty-four switches along its resistor array. The contents of the WCR can be altered in four ways: it may be written directly by the host via the Write WCR instruction (serial load); it may be written indirectly by transferring the contents of one of four associated Data Registers via the XFR Data Register instruction (parallel load); it can be modified one step at a time by the increment/decrement instruction; finally, it is loaded with the contents of its Data Register zero (DR0) upon power-up. If the application does not require storage of multiple settings for the potentiometer, these registers can be used as regular memory locations that could possibly store system parameters or user preference data. SERIAL DATA PATH SERIAL BUS INPUT FROM INTERFACE CIRCUITRY REGISTER 0 VH/RH REGISTER 1 8 6 REGISTER 2 PARALLEL BUS INPUT WIPER COUNTER REGISTER REGISTER 3 2 INC/DEC LOGIC IF WCR = 00[H] THEN VW/RW = VL/RL UP/DN IF WCR = 3F[H] THEN VW/RW = VH/RH MODIFIED SCL C O U N T E R D E C O D E UP/DN VL/RL CLK DW CASCADE CONTROL LOGIC VW/RW CM FIGURE 8. DETAILED POTENTIOMETER BLOCK DIAGRAM 8 FN8164.7 August 17, 2015 X9241A When operating in cascade mode VH/RH, VL/RL and the wiper terminals of the cascaded arrays must be electrically connected externally. All but one of the wipers must be disabled. The user can alter the wiper position by writing directly to the WCR or indirectly by transferring the contents of the Data Registers to the WCR or by using the Increment/Decrement command. Cascade Mode The X9241A provides a mechanism for cascading the arrays. That is, the sixty-three resistor elements of one array may be cascaded (linked) with the resistor elements of an adjacent array. The VL/RL of the higher order array must be connected to the VH/RH of the lower order array (See Figure 9). When using the Increment/Decrement command the wiper position will automatically transition between arrays. The current position of the wiper can be determined by reading the WCR registers; if the DW bit is "0", the wiper in that array is active. If the current wiper position is to be maintained on power-down a global XFR WCR to Data Register command must be issued to store the position in NV memory before power-down. Cascade Control Bits The data byte, for the three-byte commands, contains 6-bits (LSBs) for defining the wiper position plus 2 high order bits, CM (Cascade Mode) and DW (Disable Wiper, normal operation). The state of the CM bit (bit 7 of WCR) enables or disables cascade mode. When the CM bit of the WCR is set to "0" the potentiometer is in the normal operation mode. When the CM bit of the WCR is set to "1" the potentiometer is cascaded with its adjacent higher order potentiometer. For example; if bit 7 of WCR2 is set to "1", pot 2 will be cascaded to pot 3. It is possible to connect three or all four potentiometers in cascade mode. It is also possible to connect POT 3 to POT 0 as a cascade. The requirements for external connections of VL/RL, VH/RH and the wipers are the same in these cases. The state of DW enables or disables the wiper. When the DW bit (bit 6 of the WCR) is set to "0" the wiper is enabled; when set to "1" the wiper is disabled. If the wiper is disabled, the wiper terminal will be electrically isolated and float. POT 0 WCR0 VL0/RL0 VH0/RH0 VW0/RW0 POT 1 WCR1 VL1/RL1 VH1/RH1 VW1/RW1 POT 2 WCR2 VL2/RL2 VH2/RH2 VW2/RW2 POT 3 WCR3 = EXTERNAL CONNECTION VL3/RL3 VH3/RH3 VW3/RW3 FIGURE 9. CASCADING ARRAYS 9 FN8164.7 August 17, 2015 X9241A Absolute Maximum Ratings Thermal Information Supply Voltage (VCC) Limits X9241A. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V 10% Max Wiper Current for 2k RTOTAL . . . . . . . . . . . . . . . . . . . . . . 4mA Max Wiper Current for 10k and 50k RTOTAL . . . . . . . . . . . . . . 3mA Voltage on SCK, SCL or any address input with respect to VSS . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V Voltage on any VH/RH, VW/RW or VL/RL referenced to VSS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . +6V/-4V V = |VH/RH - VL/RL| . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10V IW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6mA Power rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mW Temperature under bias. . . . . . . . . . . . . . . . . . . . . . . . -65 to +135C Storage temperature . . . . . . . . . . . . . . . . . . . . . . . . . . -65 to +150C Pb-free reflow profile . . . . . . . . . . . . . . . . . . . . . . . . . .see link below http://www.intersil.com/pbfree/Pb-FreeReflow.asp Recommended Operating Conditions Temperature (Commercial) . . . . . . . . . . . . . . . . . . . . . 0C to +70C Temperature (Industrial). . . . . . . . . . . . . . . . . . . . . . .-40C to +85C CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product reliability and result in failures not covered by warranty. Analog Specifications (Over recommended operating conditions unless otherwise stated). LIMITS SYMBOL RTOTAL RW VTERM PARAMETER End to end resistance TYP MAX (Note 11) UNIT +20 % 130 +5 V -20 Wiper resistance Wiper Current = (VH - VL)/RTOTAL 40 Voltage on any VH/RH, VW/RW or VL/RL Pin -3.0 Noise Ref: 1kHz (Note 7) Resolution (Note 7) Absolute linearity (Note 3) Rw(n)(actual) - Rw(n)(expected) Relative linearity (Note 4) Rw(n + 1) - [Rw(n) + MI] 120 dBV 1.6 % 1 MI (Note 5) 0.2 MI (Note 5) Temperature coefficient of RTOTAL (Note 7) 300 ppm/C Ratiometric temperature coefficient (Note 7) 20 ppm/C 15/15/25 pF CH/CL/CW Potentiometer capacitances lAL MIN (Note 11) TEST CONDITION See Circuit #3 and (Note 7) RH, RI, RW leakage current DC Electrical Specifications VIN = VTERM. Device is in stand-by mode. 0.1 1 A (Over recommended operating conditions unless otherwise stated.) LIMITS SYMBOL PARAMETER TEST CONDITION MIN (Note 11) TYP MAX (Note 11) UNIT 3 mA lCC Supply current (active) ISB VCC current (standby) SCL = SDA = VCC, Addr. = VSS 500 A ILI Input leakage current VIN = VSS to VCC 10 A ILO Output leakage current VOUT = VSS to VCC 10 A VIH Input HIGH voltage VIL Input LOW voltage VOL Output LOW voltage fSCL = 100kHz, Write/Read to WCR, Other Inputs = VSS 200 2 IOL = 3mA V 0.8 V 0.4 V NOTES: 3. Absolute Linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a potentiometer. 4. Relative Linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a potentiometer. It is a measure of the error in step size. 5. MI = RTOT/63 or (RH - RL)/63, single pot 6. Max = all four arrays cascaded together, Typical = individual array resolutions. 10 FN8164.7 August 17, 2015 X9241A Endurance and Data Retention PARAMETER Minimum endurance MIN UNIT 100,000 Data changes per bit per register 100 Years Data retention Capacitance SYMBOL PARAMETER TEST CONDITION TYP UNIT CI/O (Note 7) Input/output capacitance (SDA) VI/O = 0V 19 pF CIN (Note 7) Input capacitance (A0, A1, A2, A3 and SCL) VIN = 0V 12 pF Power-up Timing SYMBOL PARAMETER MIN (Note 11) TYP MAX (Note 11) UNIT tPUR (Note 8) Power-up to initiation of read operation 1 ms tPUW (Note 8) Power-up to initiation of write operation 5 ms 50 V/ms tRVCC VCC Power up ramp rate 0.2 Power-up Requirements (Power Up sequencing can affect correct recall of the wiper registers) The preferred power-on sequence is as follows: First VCC, then the potentiometer pins. It is suggested that Vcc reach 90% of its final value before power is applied to the potentiometer pins. The VCC ramp rate specification should be met, and any glitches or slope changes in the VCC line should be held to <100mV if possible. Also, VCC should not reverse polarity by more than 0.5V. NOTES: 7. Limits should be considered typical and are not production tested. 8. Limits established by characterization and are not production tested. 9. Maximum Wiper Current is derated over temperature. See the Wiper Current Derating Curve. 10. Ti value denotes the maximum noise glitch pulse width that the device will ignore on either SCL or SDA pins. Any noise glitch pulse width that is greater than this maximum value will be considered as a valid clock or data pulse and may cause communication failure to the device. 11. Parts are 100% tested at either +70C or +85C. Over temperature limits established by characterization and are not production tested. Symbol Table AC Conditions of Test Input pulse levels VCC x 0.1 to VCC x 0.9 Input rise and fall times 10ns Input and output timing levels VCC x 0.5 Input pulse levels VCC x 0.1 to VCC x 0.9 11 WAVEFORM INPUTS OUTPUTS Must be steady Will be steady May change from LOW to HIGH Will change from LOW to HIGH May change from HIGH to LOW Will change from HIGH to LOW Don't Care: Changes Allowed Changing: State Not Known N/A Center Line is High Impedance FN8164.7 August 17, 2015 X9241A Equivalent AC Test Circuit Guidelines for Calculating Typical Values of Bus Pull-Up Resistors 5V 120 1533 RMIN = RESISTANCE (k) 100 SDA OUTPUT 100pF VCC MAX TR RMAX = 80 =1.8k IOL MIN CBUS MAXIMUM RESISTANCE 60 40 20 0 MIN. RESISTANCE 0 20 40 60 80 100 120 BUS CAPACITANCE (pF) Circuit #3 SPICE Macro Model DCP Wiper Current De-rating Curve MAXIMUM DCP WIPER CURRENT MACRO MODEL RTOTAL RH RL CL CH 15pF CW 15pF 25pF RW 7 6 5 4 3 2 1 0 0 10 20 30 40 50 60 70 80 90 AMBIENT TEMPERATURE (C) tHIGH tLOW tF tR SCL tSU:STA tHD:STA tHD:DAT tSU:DAT tSU:STO SDA (DATA IN) tBUF FIGURE 10. INPUT BUS TIMING AC Electrical Specifications (Over recommended operating conditions unless otherwise stated). LIMITS SYMBOL PARAMETER MIN (Note 11) MAX (Note 11) UNIT REFERENCE FIGURE NUMBER(S) 0 100 kHz 10 fSCL SCL clock frequency tLOW Clock LOW period 4700 ns 10 tHIGH Clock HIGH period 4000 ns 10 tR SCL and SDA rise time 1000 ns 10 tF SCL and SDA fall time 300 ns 10 Noise suppression time constant (glitch filter) 20 ns 10 Ti, (Note 11) tSU:STA Start condition setup time (for a repeated start condition) 4000 ns 10 and 12 tHD:STA Start condition hold time 4000 ns 10 and 12 12 FN8164.7 August 17, 2015 X9241A AC Electrical Specifications (Over recommended operating conditions unless otherwise stated). (Continued) LIMITS SYMBOL MIN (Note 11) PARAMETER MAX (Note 11) UNIT REFERENCE FIGURE NUMBER(S) tSU:DAT Data in setup time 250 ns 10 tHD:DAT Data in hold time 0 ns 10 ns 11 30 ns 11 Stop condition setup time 4000 ns 10 and 12 tBUF Bus free time prior to new transmission 4700 ns 10 tWR Write cycle time (nonvolatile write operation) 10 ms 13 Wiper response time from stop generation 500 s 13 Wiper response from SCL LOW 1000 s 6 tAA SCL LOW to SDA data out valid tDH Data out hold time tSU:STO tSTPWV tCLWV 3500 SCL tAA SDAOUT SDA tDH (ACK) SDAOUT SDAOUT FIGURE 11. OUTPUT BUS TIMING START CONDITION STOP CONDITION SCL tSU:STA tHD:STA tSU:STO SDA (DATA IN) FIGURE 12. START STOP TIMING SCL CLOCK 8 CLOCK 9 STOP START tWR tSTPWV SDA SDAIN ACK WIPER OUTPUT FIGURE 13. WRITE CYCLE AND WIPER RESPONSE TIMING 13 FN8164.7 August 17, 2015 X9241A Revision History The revision history provided is for informational purposes only and is believed to be accurate, but not warranted. Please go to the web to make sure that you have the latest revision. DATE REVISION August 17, 2015 FN8164.7 CHANGE - Ordering Information Table on page 2. - Added Revision History beginning with Rev 1. - Added About Intersil Verbiage. About Intersil Intersil Corporation is a leading provider of innovative power management and precision analog solutions. The company's products address some of the largest markets within the industrial and infrastructure, mobile computing and high-end consumer markets. For the most updated datasheet, application notes, related documentation and related parts, please see the respective product information page found at www.intersil.com. You may report errors or suggestions for improving this datasheet by visiting www.intersil.com/ask. Reliability reports are also available from our website at www.intersil.com/support 14 FN8164.7 August 17, 2015 X9241A Thin Shrink Small Outline Package Family (TSSOP) 0.25 M C A B D MDP0044 A THIN SHRINK SMALL OUTLINE PACKAGE FAMILY (N/2)+1 N MILLIMETERS SYMBOL 14 LD 16 LD 20 LD 24 LD 28 LD TOLERANCE PIN #1 I.D. E E1 0.20 C B A 1 (N/2) B 2X N/2 LEAD TIPS TOP VIEW 0.05 e C SEATING PLANE 0.10 M C A B b 0.10 C N LEADS H A 1.20 1.20 1.20 1.20 1.20 Max A1 0.10 0.10 0.10 0.10 0.10 0.05 A2 0.90 0.90 0.90 0.90 0.90 0.05 b 0.25 0.25 0.25 0.25 0.25 +0.05/-0.06 c 0.15 0.15 0.15 0.15 0.15 +0.05/-0.06 D 5.00 5.00 6.50 7.80 9.70 0.10 E 6.40 6.40 6.40 6.40 6.40 Basic E1 4.40 4.40 4.40 4.40 4.40 0.10 e 0.65 0.65 0.65 0.65 0.65 Basic L 0.60 0.60 0.60 0.60 0.60 0.15 L1 1.00 1.00 1.00 1.00 1.00 Reference Rev. F 2/07 NOTES: 1. Dimension "D" does not include mold flash, protrusions or gate burrs. Mold flash, protrusions or gate burrs shall not exceed 0.15mm per side. SIDE VIEW 2. Dimension "E1" does not include interlead flash or protrusions. Interlead flash and protrusions shall not exceed 0.25mm per side. SEE DETAIL "X" 3. Dimensions "D" and "E1" are measured at dAtum Plane H. 4. Dimensioning and tolerancing per ASME Y14.5M-1994. c END VIEW L1 A A2 GAUGE PLANE 0.25 L A1 0 - 8 DETAIL X 15 FN8164.7 August 17, 2015 X9241A Small Outline Package Family (SO) A D h X 45 (N/2)+1 N A PIN #1 I.D. MARK E1 E c SEE DETAIL "X" 1 (N/2) B L1 0.010 M C A B e H C A2 GAUGE PLANE SEATING PLANE A1 0.004 C 0.010 M C A B L b 0.010 4 4 DETAIL X MDP0027 SMALL OUTLINE PACKAGE FAMILY (SO) INCHES SYMBOL SO-14 SO16 (0.300") (SOL-16) SO20 (SOL-20) SO24 (SOL-24) SO28 (SOL-28) TOLERANCE NOTES A 0.068 0.068 0.068 0.104 0.104 0.104 0.104 MAX - A1 0.006 0.006 0.006 0.007 0.007 0.007 0.007 0.003 - A2 0.057 0.057 0.057 0.092 0.092 0.092 0.092 0.002 - b 0.017 0.017 0.017 0.017 0.017 0.017 0.017 0.003 - c 0.009 0.009 0.009 0.011 0.011 0.011 0.011 0.001 - D 0.193 0.341 0.390 0.406 0.504 0.606 0.704 0.004 1, 3 E 0.236 0.236 0.236 0.406 0.406 0.406 0.406 0.008 - E1 0.154 0.154 0.154 0.295 0.295 0.295 0.295 0.004 2, 3 e 0.050 0.050 0.050 0.050 0.050 0.050 0.050 Basic - L 0.025 0.025 0.025 0.030 0.030 0.030 0.030 0.009 - L1 0.041 0.041 0.041 0.056 0.056 0.056 0.056 Basic - h 0.013 0.013 0.013 0.020 0.020 0.020 0.020 Reference - 16 20 24 28 Reference - N SO-8 SO16 (0.150") 8 14 16 Rev. M 2/07 NOTES: 1. Plastic or metal protrusions of 0.006" maximum per side are not included. 2. Plastic interlead protrusions of 0.010" maximum per side are not included. 3. Dimensions "D" and "E1" are measured at Datum Plane "H". 4. Dimensioning and tolerancing per ASME Y14.5M-1994 16 FN8164.7 August 17, 2015 X9241A Plastic Dual-In-Line Packages (PDIP) E D A2 SEATING PLANE L N A PIN #1 INDEX E1 c e b A1 NOTE 5 1 eA eB 2 N/2 b2 MDP0031 PLASTIC DUAL-IN-LINE PACKAGE INCHES SYMBOL PDIP8 PDIP14 PDIP16 PDIP18 PDIP20 TOLERANCE A 0.210 0.210 0.210 0.210 0.210 MAX A1 0.015 0.015 0.015 0.015 0.015 MIN A2 0.130 0.130 0.130 0.130 0.130 0.005 b 0.018 0.018 0.018 0.018 0.018 0.002 b2 0.060 0.060 0.060 0.060 0.060 +0.010/-0.015 c 0.010 0.010 0.010 0.010 0.010 +0.004/-0.002 D 0.375 0.750 0.750 0.890 1.020 0.010 E 0.310 0.310 0.310 0.310 0.310 +0.015/-0.010 E1 0.250 0.250 0.250 0.250 0.250 0.005 e 0.100 0.100 0.100 0.100 0.100 Basic eA 0.300 0.300 0.300 0.300 0.300 Basic eB 0.345 0.345 0.345 0.345 0.345 0.025 L 0.125 0.125 0.125 0.125 0.125 0.010 N 8 14 16 18 20 Reference NOTES 1 2 Rev. C 2/07 NOTES: 1. Plastic or metal protrusions of 0.010" maximum per side are not included. 2. Plastic interlead protrusions of 0.010" maximum per side are not included. 3. Dimensions E and eA are measured with the leads constrained perpendicular to the seating plane. 4. Dimension eB is measured with the lead tips unconstrained. 5. 8 and 16 lead packages have half end-leads as shown. All Intersil U.S. products are manufactured, assembled and tested utilizing ISO9001 quality systems. Intersil Corporation's quality certifications can be viewed at www.intersil.com/design/quality Intersil products are sold by description only. Intersil Corporation reserves the right to make changes in circuit design, software and/or specifications at any time without notice. Accordingly, the reader is cautioned to verify that data sheets are current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or otherwise under any patent or patent rights of Intersil or its subsidiaries. For information regarding Intersil Corporation and its products, see www.intersil.com 17 FN8164.7 August 17, 2015