General-purpose Relay G2R-@-S CSM_G2R-_-S_DS_E_3_3 Slim and Space-saving Power Plug-in Relay Lockable test button models now available. Built-in mechanical operation indicator. Provided with nameplate. AC type is equipped with a coil-disconnection self-diagnostic function (LED type). High switching power (1-pole: 10 A). Environment-friendly (Cd, Pb free). Wide range of Sockets also available. LR For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Model Number Legend G2R - - 1 2 3 4 5 1. Relay Function Blank: General-purpose 6 7 5. Terminals S: Plug-in 2. Number of Poles 1: 1 pole 2: 2 poles 6. Classification Blank: General-purpose N: LED indicator D: Diode ND: LED indicator and diode NI: LED indicator with test button NDI: LED indicator and diode with test button 3. Contact Form Blank: SPDT 4. Contact Type Blank: Single 7. Rated Coil Voltage Ordering Information When your order, specify the rated voltage. List of Models Classification Enclosure rating Coil ratings General-purpose LED indicator Plug-in terminal LED indicator with test button Diode LED indicator and diode LED indicator and diode with test button AC/DC Unsealed DC Contact form SPDT DPDT G2R-1-S G2R-2-S G2R-1-SN G2R-2-SN G2R-1-SNI (S) G2R-2-SNI (S) G2R-1-SD G2R-2-SD G2R-1-SND G2R-2-SND G2R-1-SNDI (S) G2R-2-SNDI (S) Note: 1. The standard models are compliant with UL/CSA and VDE standards. Also, an EC compliance declaration has been made for combinations with the P2RF-E and P2RF-S. The Relays bear the CE Marking. 2. Refer to Connecting Sockets, below, for applicable Socket models. 3. When ordering, add the rated coil voltage and "(S)" to the model number. Rated coil voltages are given in the coil ratings table. New model Example: G2R-1-S 12 VDC (S) Rated coil voltage 1 G2R-@-S Accessories (Order Separately) Connecting Sockets Track/surface-mounting Socket Applicable Relay model Screwless clamp terminal 1 pole G2R-1-S(N)(D)(ND)(NI)(NDI) * P2RF-05S (See note.) + (P2CM-S (option)) 2 poles G2R-2-S(N)(D)(ND)(NI)(NDI) * P2RF-08S (See note.) + (P2CM-S (option)) Back-mounting Socket Screw terminal Terminals Model * P2RF-05-E * P2RF-05 PCB terminals P2R-05P, P2R-057P Solder terminals P2R-05A * P2RF-08-E * P2RF-08 PCB terminals P2R-08P, P2R-087P Solder terminals P2R-08A Note: Use of the P2CM Clip & Release Lever is recommended to ensure stable mounting. Accessories for Screwless Clamp Terminal Socket (Option) Name Model Clip & Release Lever P2CM-S Nameplate R99-11 Nameplate for MY Socket Bridge P2RM-SR (for AC), P2RM-SB (for DC) Mounting Tracks Applicable Socket Description Model Mounting track 50 cm (l) x 7.3 mm (t): PFP-50N 1 m (l) x 7.3 mm (t): PFP-100N 1 m (l) x 16 mm (t): PFP-100N2 End plate PFP-M Track-connecting Socket Back-connecting Socket Spacer PFP-S Mounting plate P2R-P* * Used to mount several P2R-05A and P2R-08A Connecting Sockets side by side. Specifications Coil Ratings Rated current* Rated voltage 50 Hz AC 60 Hz Coil inductance (H) (ref. value) Armature OFF Armature ON 24 V 43.5 mA 37.4 mA 253 0.81 1.55 110 V 9.5 mA 8.2 mA 5,566 13.33 26.83 120 V 8.6 mA 7.5 mA 7,286 16.13 32.46 230 V 4.4 mA 3.8 mA 27,172 72.68 143.90 240 V 3.7 mA 3.2 mA 30,360 90.58 182.34 Rated voltage DC Coil resistance* Rated current* Coil resistance* Coil inductance (H) (ref. value) Armature OFF Armature ON 6V 87.0 mA 69 0.25 12 V 43.2 mA 278 0.98 2.35 24 V 21.6 mA 1,113 3.60 8.25 48 V 11.4 mA 4,220 15.2 29.82 Must operate voltage Must release voltage Max. voltage % of rated voltage 80% max. 30% max. Must operate voltage Must release voltage 110% Max. voltage % of rated voltage Power consumption (approx.) 0.9 VA at 60 Hz Power consumption (approx.) 0.48 70% max. 15% min. 110% 0.53 W * The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of 10%. 2 G2R-@-S Contact Ratings Number of poles 1 pole Load Resistive load (cos = 1) Inductive load (cos = 0.4; L/R = 7 ms) Resistive load (cos = 1) 2 poles Inductive load (cos = 0.4; L/R = 7 ms) Rated load 10 A at 250 VAC; 10 A at 30 VDC 7.5 A at 250 VAC; 5 A at 30 VDC 5 A at 250 VAC; 5 A at 30 VDC 2 A at 250 VAC; 3 A at 30 VDC Rated carry current 10 A 5A Max. switching voltage 440 VAC, 125 VDC 380 VAC, 125 VDC Max. switching current 10 A Max. switching power 2,500 VA, 300 W Failure rate (reference value) 100 mA at 5 VDC 5A 1,875 VA, 150 W 1,250 VA, 150 W 500 VA, 90 W 10 mA at 5 VDC Note: P level: 60 = 0.1 x 10-6/operation Characteristics Item 1 pole 2 poles Contact resistance 100 m max. Operate (set) time 15 ms max. Release (reset) time AC: 10 ms max.; DC: 5 ms max. (w/built-in diode: 20 ms max.) Max. operating frequency Mechanical: Electrical: Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 5,000 VAC, 50/60 Hz for 1 min between coil and 5,000 VAC, 50/60 Hz for 1 min between coil and contacts*; contacts*; 3,000 VAC, 50/60 Hz for 1 min between contacts of different polarity 1,000 VAC, 50/60 Hz for 1 min between contacts of 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity same polarity Vibration resistance Destruction: Malfunction: 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) Shock resistance Destruction: Malfunction: 1,000 m/s2 200 m/s2 when energized; 100 m/s2 when not energized Mechanical: AC coil: 10,000,000 operations min.; DC coil: 20,000,000 operations min. (at 18,000 operations/hr) 100,000 operations min. (at 1,800 operations/hr under rated load) (DC coil type) Endurance Electrical: AC: 15 ms max.; DC: 10 ms max. (w/built-in diode: 20 ms max.) 18,000 operations/hr 1,800 operations/hr (under rated load) Ambient temperature Operating: -40C to 70C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 21 g Note: Values in the above table are the initial values. *4,000 VAC, 50/60 Hz for 1 minute when the P2R-05A or P2R-08A Socket is mounted. Approved Standards UL 508 (File No. E41643) Model Contact form Coil ratings G2R-1-S SPDT 5 to 110 VDC 6 to 240 VAC G2R-2-S DPDT IEC/VDE (EN61810) Contact ratings Operations Contact form 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 1 pole 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 440 VAC (cos = 1.0) 10 A, 250 VAC (cos = 1.0) 10 A, 30 VDC (0 ms) 100 x 103 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 2 poles 6, 12, 24, 48 VDC 24, 110, 120, 230, 240 VAC 5 A, 250 VAC (cos =1.0) 5 A, 30 VDC (0 ms) 100 x 103 CSA 22.2 No.0, No.14 (File No. LR31928) Model Contact form Coil ratings G2R-1-S SPDT 5 to 110 VDC 6 to 240 VAC G2R-2-S DPDT Coil ratings Contact ratings Operations LR Contact ratings Operations 10 A, 30 VDC (resistive) 10 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 5 A, 30 VDC (resistive) 5 A, 250 VAC (general use) TV-3 (NO contact only) 6 x 103 Number of poles Coil ratings Contact ratings Operations 1 pole 5 to 110 VDC 6 to 240 VDC 10 A, 250 VAC (general use) 7.5 A, 250 VAC (PF0.4) 10 A, 30 VDC (resistive) 5A, 30VDC (L/R=7ms) 100 x 103 2 poles 5 to 110 VDC 6 to 240 VDC 5 A, 250 VAC (general use) 2 A, 250 VAC (PF0.4) 5 A, 30 VDC (resistive) 3A, 30VDC (L/R=7ms) 100 x 103 3 G2R-@-S Engineering Data Maximum Switching Power Plug-in Relays G2R-2-S G2R-1-S 100 Switching current (A) AC inductive load (cos = 0.4) AC resistive load 10 DC resistive load DC inductive load (L/R = 7 ms) 1 0.1 1 10 100 Switching current (A) 100 AC resistive load DC resistive load 1 0.1 1000 AC inductive load (cos = 0.4) 10 DC inductive load (L/R = 7 ms) 1 10 Switching voltage (V) 100 1000 Switching voltage (V) Endurance Plug-in Relays G2R-2-S 10,000 5,000 1,000 250-VAC/30-VDC resistive load 500 100 250-VAC inductive load (cos = 0.4) 30-VDC inductive load (L/R = 7ms) 50 Switching current (A) Endurance (x103 operations) Endurance (x103 operations) G2R-1-S 5,000 1,000 500 30-VDC inductive load (L/R = 7ms) 250-VAC/30-VDC resistive load 100 250-VAC 50 inductive load (cos = 0.4) Switching current (A) Maximum voltage (%) Ambient Temperature vs Maximum Coil Voltage DC coil AC coil Note: The maximum voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient temperature (C) 4 G2R-@-S Dimensions Note: All units are in millimeters unless otherwise indicated. Relays with Plug-in Terminals SPDT Relays G2R-1-S, G2R-1-SN, G2R-1-SNI (S) G2R-1-SD, G2R-1-SND, G2R-1-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-1-SD (DC) G2R-1-S 29 max. 1 13 max. 1 2 20 35.5 max. 5 4 3 G2R-1-SN, G2R-1-SNI (AC) 4.75 2 5 3 4 5 2 4 3 7.5 0.5 1 5 1 24V 3 4 G2R-1-SN, G2R-1-SNI (DC) 1 DC 2 5 G2R-1-SND, G2R-1-SNDI (DC) 5.2 5.2 17.5 1 2 5 4 3 DPDT Relays G2R-2-S, G2R-2-SN, G2R-2-SNI (S) G2R-2-SD, G2R-2-SND, G2R-2-SNDI (S) Terminal Arrangement/Internal Connections (Bottom View) G2R-2-S 1 2 3 4 8 7 6 5 13 max. 2.5 35.5 max. 1 2 3 4 8 7 6 5 G2R-2-SN, G2R-2-SNI (DC) 1 2 3 4 1 2 3 4 8 7 6 5 8 7 6 5 7.4 8.9 2.4 G2R-2-SN, G2R-2-SNI (AC) 6.2 20 29 max. 0.5 G2R-2-SD (DC) G2R-2-SND, G2R-2-SNDI (DC) 5 5 19.4 1 2 3 4 8 7 6 5 5 G2R-@-S Track/Surface Mounting Sockets 38.2 max. P2RF-05-S Terminal Arrangement (Top View) 36.5 max. 11 32.6 14 27.6 12 Option (with ejector and label attached) 92.0 max. Standard model 35.4 24.5 22.6 (5.3) 28.5 18.0 max. A1 A2 32.6 Terminal Arrangement (Top View) 38.2 max. P2RF-08-S 36.5 max. 21 11 24 14 32.6 27.6 22 12 (3.4) Standard model 35.4 92.0 max. 24.5 22.6 A1 A2 Option (with ejector and label attached) (5.3) 28.6 18.0 max. 32.6 Accessories for P2RF-@-S Socket Bridge Clip and Release Lever Insulating coating L 1.2 dia. conductor (See note 1.) 14 16.8 40.35 36 9 6 G2R-@-S Terminal Arrangement (Top View) P2RF-05-E Five, M3.5x7 2 48 max. 4 (14) 39.5 3 35.5 85.5 max. Mounting Holes (for Surface Mounting) 3.2-dia. hole (11) 2 (12) 39.50.1 3.5-dia. hole M3 or 3.5-dia. hole 5 (A1) (A2) 1 11.5 61 max. 16.0 max. Note: Pin numbers in parentheses apply to DIN standard. P2RF-08-E 2 Terminal Arrangement (Top View) 2 1.5 Eight, M3x8 48.0 max. Mounting Holes (for Surface Mounting) 3 39.5 (21) (22) (24) 6 3 7 5 2 4 (11) (12) (14) 3.2-dia. hole 35.5 85.5 max. 39.50.1 3.5-dia. hole 8 (A1) (A2) 5 61.0 max. 1 M3 or 3.5-dia. hole 11.5 16.0 max. P2RF-05 2 7 Terminal Arrangement (Top View) Five, M3.5 x 8 4-dia. holes Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 300.05 4 19.5 30 max. 19.5 max. M3 or 3.2-dia. hole 54 max. P2RF-08 2 7 Eight, M3.5 x 8 4-dia. holes Terminal Arrangement (Top View) Mounting Holes (for Surface Mounting) 4.2-dia. hole 35.5 71.5 max. 300.05 4 19.5 max. 19.5 30 max. 54 max. M3 or 3.2-dia. hole 7 G2R-@-S Mounting Height of Relay with Track/Surface Mounting Sockets P2RF-@-E P2RF-@ 62.0 66.5 70.5 67.0 P2RF-@-S 72.0 65.0 28.6 (5.30) Back-connecting Sockets P2R-05P (1-pole) 4 1 Terminal Arrangement (Bottom View) 14.5 max. 7 Mounting Holes Tolerance: 0.1 4 6 4.5 6 35.5 max. 15 Five, 1.6-dia. holes 4.5 1.2 4 15 3.5 4 1.5 (5) 4 7 7 36.5 max. P2R-08P (2-pole) 4 0.3 14.5 max. 7 Terminal Arrangement (Bottom View) Mounting Holes 7.5 Eight, 1.3-dia. holes 5 5 35.5 max. 20 1 5 5 20 2.8 1.5 (4.3) 7.5 Terminal plate thickness: 0.3 36.5 max. 8 G2R-@-S 5 P2R-05A (1-pole) 7 14.5 max. 1.2 0.3 Terminal Arrangement (Bottom View) 6.7 3.8 35.5 max. 5 16.7 Panel Cutout Five, 3 x 1.8-dia. holes 13.60.1 6 36.5 max. Terminal plate thickness: 0.3 P2R-08A (2-pole) 7 30.50.2 7 14.5 max. 1.2 0.3 5 5 35.5 max. Recommended thickness of the panel is 1.6 to 2.0 mm 20 2.6 2.8 1.5 Eight, 3 x 1.2-dia. holes 7.5 Terminal plate thickness: 0.3 P2R-057P 0.7 14 max. 8.7 16.4 10.4 1 36.5 max. Terminal Arrangement (Bottom View) Mounting Holes 40.1 Five, 1.6-dia. holes 60.1 37 max.29.6 4.50.1 150.1 8.7 40.1 5 7.4 70.1 41 max. P2R-087P 14 max. 7.5 Terminal Arrangement (Bottom View) 16.4 1 10.4 Mounting Holes 7.5 37 max. 29.1 Eight, 1.3-dia. holes 5 5 20 7.4 8.9 (8.1) 41 max. Mounting Height of Relay with Back-connecting Sockets G2R-@P G2R-@A G2R-@7P G2R Relay G2R Relay 44.5 P2R-_P Socket 47.5 38.0 P2R-_A Socket 9 G2R-@-S Mounting Tracks PFP-100N, PFP-50N PFP-100N2 16 7.30.15 4.5 4.5 15 25 25 25 25 10 10 1,000 (500) 350.3 27 270.15 350.3 15 (5) 15 1 25 25 15 25 25 10 10 24 29.2 1 1.5 1,000 It is recommended to use a panel 1.6 to 2.0 mm thick. End Plate Spacer 10 6.2 PFP-M PFP-S 16 12 5 1.8 1 50 1.8 11.5 10 M4 x 8 pan head screw 35.5 35.3 34.8 44.3 1.3 4.8 16.5 Precautions Cation * Do not use the test button for any purpose other than testing. Be sure not to touch the test button accidentally as this will turn the contacts ON. Before using the test button, confirm that circuits, the load, and any other connected item will operate safely. * Check that the test button is released before turning ON relay circuits. * If the test button is pulled out too forcefully, it may bypass the momentary testing position and go straight into the locked position. * Use an insulated tool when you operate the test button. Precautions for P2RF-@-S Connection * Do not move the screwdriver up, down, or from side to side while it is inserted in the hole. Doing so may cause damage to internal components (e.g., deformation of the clamp spring or cracks in the housing) or cause deterioration of insulation. * Do not insert the screwdriver at an angle. Doing so may break the side of the socket and result in a short-circuit. 10 Terms and Conditions Agreement Read and understand this catalog. Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Warranties. (a) Exclusive Warranty. Omron's exclusive warranty is that the Products will be free from defects in materials and workmanship for a period of twelve months from the date of sale by Omron (or such other period expressed in writing by Omron). Omron disclaims all other warranties, express or implied. (b) Limitations. OMRON MAKES NO WARRANTY OR REPRESENTATION, EXPRESS OR IMPLIED, ABOUT NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OF THE PRODUCTS. BUYER ACKNOWLEDGES THAT IT ALONE HAS DETERMINED THAT THE PRODUCTS WILL SUITABLY MEET THE REQUIREMENTS OF THEIR INTENDED USE. Omron further disclaims all warranties and responsibility of any type for claims or expenses based on infringement by the Products or otherwise of any intellectual property right. (c) Buyer Remedy. Omron's sole obligation hereunder shall be, at Omron's election, to (i) replace (in the form originally shipped with Buyer responsible for labor charges for removal or replacement thereof) the non-complying Product, (ii) repair the non-complying Product, or (iii) repay or credit Buyer an amount equal to the purchase price of the non-complying Product; provided that in no event shall Omron be responsible for warranty, repair, indemnity or any other claims or expenses regarding the Products unless Omron's analysis confirms that the Products were properly handled, stored, installed and maintained and not subject to contamination, abuse, misuse or inappropriate modification. Return of any Products by Buyer must be approved in writing by Omron before shipment. Omron Companies shall not be liable for the suitability or unsuitability or the results from the use of Products in combination with any electrical or electronic components, circuits, system assemblies or any other materials or substances or environments. Any advice, recommendations or information given orally or in writing, are not to be construed as an amendment or addition to the above warranty. See http://www.omron.com/global/ or contact your Omron representative for published information. Limitation on Liability; Etc. OMRON COMPANIES SHALL NOT BE LIABLE FOR SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES, LOSS OF PROFITS OR PRODUCTION OR COMMERCIAL LOSS IN ANY WAY CONNECTED WITH THE PRODUCTS, WHETHER SUCH CLAIM IS BASED IN CONTRACT, WARRANTY, NEGLIGENCE OR STRICT LIABILITY. Further, in no event shall liability of Omron Companies exceed the individual price of the Product on which liability is asserted. Suitability of Use. Omron Companies shall not be responsible for conformity with any standards, codes or regulations which apply to the combination of the Product in the Buyer's application or use of the Product. At Buyer's request, Omron will provide applicable third party certification documents identifying ratings and limitations of use which apply to the Product. This information by itself is not sufficient for a complete determination of the suitability of the Product in combination with the end product, machine, system, or other application or use. Buyer shall be solely responsible for determining appropriateness of the particular Product with respect to Buyer's application, product or system. Buyer shall take application responsibility in all cases. NEVER USE THE PRODUCT FOR AN APPLICATION INVOLVING SERIOUS RISK TO LIFE OR PROPERTY OR IN LARGE QUANTITIES WITHOUT ENSURING THAT THE SYSTEM AS A WHOLE HAS BEEN DESIGNED TO ADDRESS THE RISKS, AND THAT THE OMRON PRODUCT(S) IS PROPERLY RATED AND INSTALLED FOR THE INTENDED USE WITHIN THE OVERALL EQUIPMENT OR SYSTEM. Programmable Products. Omron Companies shall not be responsible for the user's programming of a programmable Product, or any consequence thereof. Performance Data. Data presented in Omron Company websites, catalogs and other materials is provided as a guide for the user in determining suitability and does not constitute a warranty. It may represent the result of Omron's test conditions, and the user must correlate it to actual application requirements. Actual performance is subject to the Omron's Warranty and Limitations of Liability. Change in Specifications. Product specifications and accessories may be changed at any time based on improvements and other reasons. It is our practice to change part numbers when published ratings or features are changed, or when significant construction changes are made. However, some specifications of the Product may be changed without any notice. When in doubt, special part numbers may be assigned to fix or establish key specifications for your application. Please consult with your Omron's representative at any time to confirm actual specifications of purchased Product. Errors and Omissions. Information presented by Omron Companies has been checked and is believed to be accurate; however, no responsibility is assumed for clerical, typographical or proofreading errors or omissions. 2015.10 In the interest of product improvement, specifications are subject to change without notice. OMRON Corporation Industrial Automation Company http://www.ia.omron.com/ (c)Copyright OMRON Corporation 2015 All Right Reserved.