D-63E2S
E2S
Rating/Performance
DC 2-wire Models
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.
DC 3-wire Models
* The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the
size of the sensing object and the sensing distance set is half of the maximum sensing distance.
Model E2S-W11
E2S-W12
E2S-Q11
E2S-Q12
E2S-W21
E2S-W22
E2S-Q21
E2S-Q22
Item
Sensing surface Front face End face Front face End face
Sensing distance 1.6 mm ±10% 2.5 mm ±15%
Setting distance
0 to 1.2 mm
0 to 1.9 mm
Differential distance 10% max.
Sensing object Ferrous metal (Sensitivity lowers with non-ferrous metals)
Standard sensing
object Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm
Response frequency 1 kHz min.
Rated supply voltage
(operating voltage) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Leakage current 0.8 mA max.
Control
output
Switching
capacity 3 to 50 mA DC max.
Residual
voltage 3 V max. (under load current of 50 mA with cable length of 1 m)
Indicator lamp ##1 models: Operation indicator(red LED), Operation set indicator(green LED)
##2 models: Operation indicator(red LED)
Operating status
(with sensing object
approaching)
##1 models: NO
##2 models: NC
Model E2S-W13
E2S-W14
E2S-Q13
E2S-Q14
E2S-W23
E2S-W24
E2S-Q23
E2S-Q24
E2S-W15
E2S-W16
E2S-Q15
E2S-Q16
E2S-W25
E2S-W26
E2S-Q25
E2S-Q26
Item
Sensing surface Front face End face Front face End face Front face End face Front face End face
Sensing distance 1.6 mm ±10% 2.5 mm ±15% 1.6 mm ±10% 2.5 mm ±15%
Setting distance
0 to 1.2 mm
0 to 1.9 mm 0 to 1.2 mm 0 to 1.9 mm
Differential distance 10% max.
Sensing object Ferrous metal
Standard sensing
object Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm Iron, 12 x 12 x 1 mm Iron, 15 x 15 x 1 mm
Response frequency 1 kHz min.
Rated supply voltage
(operating voltage) 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.
Current consumption 13 mA max. (24 VDC, unload)
Control
output
Switching
capacity NPN open collector 100 mA max. (30 VDC max.) PNP open collector 50 mA max. (30 VDC max.)
Residual
voltage 1 V max. (under load current of 50 mA with cable length of 1 m)
Indicator lamp Operation indicator (orange)
Operating status
(with sensing object
approaching)
##3 models: NO
##4 models: NC
##5 models: NO
##6 models: NC
F502-EN2-04.book Seite 63 Dienstag, 26. Juli 2005 5:48 17