120W Single Output Switching Power Supply EPS-120 series
EPS - 120
Model Encoding
Description
EPS-120 is a 120W highly reliable green PCB type power supply with a high power density on the 4 by 2
footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V. The working
efficiency is up to 91% and the extremely low no load power consumption is down below 0.3W. EPS-120
is able to be used for both Class (with FG) and Class (no FG) system design. EPS-120 has the complete ⅠⅡ
protection functions; it is complied with the international safety regulations such as TUV EN62368-1,
UL62368-1 and IEC62368-1. EPS-120 series serves as a high price-to-performance power supply solution
for various industrial applications.
Industrial automation machinery
Industrial control system
Mechanical and electrical equipment
Electronic instruments, equipments or
apparatus
Features Applications
Output voltage
Output wattage
-12
4"×2" miniature size
Universal AC input / Full range
EMI Class B for both Class (with FG) and Class (without FG)
configuration
No load power consumption<0.3W
High efficiency up to 91%
Protections: Short circuit / Overload / Over voltage
/ Over temperature
Cooling by free air convection for 84W and 120W with
10CFM forced air
Built-in 12V/0.5A fan supply
LED indicator for power on
Operating altitude up to 5000 meters
3 years warranty
Series name
File Name:EPS-120-SPEC 2020-10-20
Bauar
Sicherheit
egel gema
t gepruf t
od
be
www.
ID 2000000000
tuv.com
wac g
os
TPTC004
UL62368-1 EN62368-1 IEC62368-1
120W Single Output Switching Power Supply EPS-120 series
SPECIFICATION
MODEL
DC VOLTAGE
CURRENT 10CFM
10CFM
Convection
Convection
RATED
POWER
OUTPUT
LINE REGULATION
VOLTAGE ADJ. RANGE
LOAD REGULATION
SETUP, RISE TIME
HOLD UP TIME (Typ.)
VOLTAGE RANGE Note.4
FREQUENCY RANGE
EFFICIENCY (Typ.)
INPUT
FUNCTION
INRUSH CURRENT (Typ.)
LEAKAGE CURRENT
WORKING HUMIDITY
WORKING TEMP.
OVER TEMPERATURE
STORAGE TEMP., HUMIDITY
TEMP. COEFFICIENT
VIBRATION
MTBF
DIMENSIONOTHERS
NOTE
PACKING
OVERLOAD
OVER VOLTAGE
AC CURRENT (Typ.)
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
50ms/230VAC 10ms/115VAC at full load
80 ~ 264VAC 113 ~ 370VDC
47 ~ 63Hz
88.5%88% 90%
16.5 ~ 19.5V
90%
26.4 ~ 31.2V
91%
29.7 ~ 35V 52.8 ~ 62.4V
2.1A/115VAC 1.2A/230VAC
COLD START 30A/115VAC 60A/230VAC
115~150% rated output power
13.2 ~ 15.6V
Protection type : Hiccup mode, recovers automatically after fault condition is removed
20 ~ 90% RH non-condensing
-30 ~ +70 (Refer to "Derating Curve")
Protection type : Shut down o/p voltage, re-power on to recover
-40 ~ +85 , 10 ~ 95% RH
±℃ 0.03%/ (0 ~ 50 )
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
653.5Khrs min. MIL-HDBK-217F (25 )
101.6*50.8*29mm (L*W*H)
0.15Kg; 72pcs/11.8Kg/0.82CUFT
±1.0%
±0.5%
±1.0%
±0.5%
±1.0%
±0.5% ±0.5%
±1.0% ±1.0%
±0.5%
±2.0% ±2.5% ±1.0% ±1.0% ±1.0%
120mVp-p
11.4~12.6V 14.3~15.8V 22.8~25.2V 25.6 ~ 28.4V 45.6 ~50.4V
120mVp-p 150mVp-p 150mVp-p 200mVp-p
15V 24V 27V 48V
10A 8A 5A 4.5A 2.5A
120W 120W 120W 121.5W 120W
EPS-120-12 EPS-120-15 EPS-120-24 EPS-120-27 EPS-120-48
SAFETY STANDARDS
RIPPLE & NOISE (max.)
Note.2
VOLTAGE TOLERANCE
Note.3
1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature.
2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3. Tolerance : includes set up tolerance, line regulation and load regulation.
4. Derating may be needed under low input voltages. Please check the derating curve for more details.
5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by
mounting the unit on a mm* mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets 360 360
EMC directives. For guidance on how to perform these EMC tests, please refer to EMI testing of component power supplies.
(as available on http://www.meanwell.com)
6. The ambient temperature derating of 3.5 /1000m with fanless models and of 5 /1000m with fan models for operating altitude higher ℃℃
than 2000m(6500ft).
Product Liability Disclaimer For detailed information, please refer to https://www.meanwell.com/serviceDisclaimer.aspx
ENVIRONMENT
SAFETY &
EMC
(Note 5)
PROTECTION
Protection type : Shut down o/p voltage, re-power on to recover
Compliance to EN55032 (CISPR32) Class B, EN61000-3-2,-3, EAC TP TC 020
Compliance to EN61000-4-2,3,4,5,6,8,11, EN55024, EN61000-6-2, heavy industry level, criteriaA, EAC TP TC 020
UL62368-1, TUV EN62368-1, IEC62368-1, approvedEAC TP TC 004
12V
EMC IMMUNITY
EMC EMISSION
<0.75mA / 240VAC
WITHSTAND VOLTAGE
ISOLATION RESISTANCE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25 / 70% RH
7.0A 5.6A 3.5A 3.15A 1.75A
84W 84W 84W 85W 84W
FAN SUPPLY 12V@0.5A for driving a fan ; tolerance -15% ~ +10%
File Name:EPS-120-SPEC 2020-10-20
OPERATING ALTITUDE
Note.6
5000 meters
Block Diagram
Output Derating VS Input VoltageDerating Curve
fosc : 65KHz
CIRCUIT
DETECTION
O.L.P.O.T.P.
EMI
FILTER
POWER
SWITCHING FILTER
FILTER
&
&
RECTIFIERS
RECTIFIERS
+V
-V
I/P
FG
CONTROL
O.V.P.
EMI FILTER
RECTIFIER
&
INPUT VOLTAGE (VAC) 60Hz
80 11590 120120 160140 200180 240220 264
LOAD (%)
90
100
80
70
60
50
40
AMBIENT TEMPERATURE ( )
LOAD (%)
-30 0 2010 30 40 45
20
40
80
60
70
100
6050 70 (HORIZONTAL)
With 10CFM Fan
Convection
for 24V~48V
Convection
for V~ V12 15
120W Single Output Switching Power Supply EPS-120 series
+12V
FAN SUPPLY
File Name:EPS-120-SPEC 2020-10-20
Mechanical Specification Unit:mm
AC Input Connector (CN1) : JST B3P-VH or equivalent
Pin No.
1
2
3
Assignment
AC/N
No Pin
AC/L
Mating Housing
JST VHR JST SVH-21T-P1.1
or equivalent or equivalent
Terminal
DC Output Connector (CN2) : JST B4P-VH or equivalent
Pin No.
1,2
3,4
Assignment
-V
+V
Mating Housing
JST VHR
or equivalent
Terminal
JST SVH-21T-P1.1
or equivalent
Mating Housing
JST PHR-2
or equivalent
Terminal
JST SPH-002T-P0.5S
or equivalent
FAN Connector(CN101) : or equivalentJST B2B-PH-K-S
Pin No.
1
2
Assignment
+12V
DC COM
: Grounding required
1.HS1,HS2 cannot be shorted.
2.HS1 must have safety isolation distance
with system case.
Note
120W Single Output Switching Power Supply EPS-120 series
FS1
HS1
HS2
T4A/250V
T4A/250V
50.8
44.45 3.175
1
2
3
CN1
FS2
3.175 95.25
101.6
4- 3.3ψ
29
3 max.
1
2
3
CN2
4
12
CN101 SVR1LED
FAN 10CFM
direction
Air flow
50mm
Note : 1. The FAN SUPPLY is designed to serve as the source of the additive external fan for the cooling of the power supply, enabling the full load delivery and assuring the best
2.The PCB type(Blank type)model delivers EMI Class B for both conducted emission and radiated emission for the power supply, when configured into either Class (with FG)
life span of the product. Please do not use this FAN SUPPLY to drive other devices.
or Class (without FG) system.
Installation Manual
Please refer to : http://www.meanwell.com/manual.html
File Name:EPS-120-SPEC 2020-10-20
50.8