2007-04-03 1
200 7- 04- 0 3
Silicon NPN Phototransistor
NPN-Silizium-Fototransistor
Version 1.0
SFH 314, SFH 314 FA
SFH 314 FASFH 314
Ordering Information
Bestellinformation
Features: Besondere Merkmale:
Spectral range of sensitivity: 460 nm...1080 nm
(SFH 314), 740 nm... 1080 nm (SFH 314 FA)
Spektraler Bereich der Fotoempfindlichkeit:
460 nm...1080 nm (SFH 314), 740 nm... 1080 nm
(SFH 314 FA)
Package: 5mm Radial (T 1 ¾), Epoxy Gehäuse: 5mm Radial (T 1 ¾), Harz
Special: High linearity Besonderheit: Hohe Linearität
Applications Anwendungen
Computer-controlled flashes Computer-Blitzlichtgeräte
Photointerrupters Lichtschranken
Industrial electronics Industrieelektronik
For control and drive circuits Messen / Steuern / Regeln
Type: Photocurrent Ordering Code
Typ: Fotostrom Bestellnummer
λ = 950 nm, Ee = 0.5 mW/cm2, VCE = 5 V
IPCE [µA]
SFH 314 630 Q62702P1668
SFH 314-2/3 1000 ... 3200 Q62702P3600
SFH 314 FA 630 Q62702P1675
SFH 314 FA-2/3 1000 ... 3200 Q62702P3599
Note: Only one bin within one packing unit (variation less than 2:1)
Anm.: Nur eine Gruppe pro Verpackungseinheit (Streuung kleiner 2:1)
2007-04-03 2
Version 1.0 SFH 314, SFH 314 FA
Maximum Ratings (TA = 25 °C)
Grenzwerte
Characteristics (TA = 25 °C)
Kennwerte
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
SFH 314 SFH 314 FA
Operating and storage temperature range
Betriebs- und Lagertemperatur
Top; Tstg -40 ... 100 °C
Collector-emitter voltage
Kollektor-Emitter-Spannung
VCE 70 V
Collector current
Kollektorstrom
IC50 mA
Collector surge current
Kollektorspitzenstrom
(τ < 10 µs)
ICS 100 mA
Emitter-collector voltage
Emitter-Kollektor-Spannung
VEC 7V
Total power dissipation
Verlustleistung
Ptot 200 mW
Thermal resistance
Wärmewiderstand
RthJA 375 K / W
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
SFH
314
SFH
314 FA
Wavelength of max. sensitivity
Wellenlänge der max. Fotoempfindlichkeit
λS max 850 870 nm
Spectral range of sensitivity
Spektraler Bereich der Fotoempfindlichkeit
λ10% 460 ...
1080
740 ...
1080
nm
Radiant sensitive area
Bestrahlungsempfindliche Fläche
A0.55mm
2
Dimensions of chip area
Abmessung der Chipfläche
L x W 1 x 1 mm x
mm
Half angle
Halbwinkel
ϕ± 40 °
Version 1.0 SFH 314, SFH 314 FA
2007-04-03 3
Capacitance
Kapazität
(VCE = 5 V, f = 1 MHz, E = 0)
CCE 10 pF
Dark current
Dunkelstrom
(VCE = 10 V, E = 0)
ICE0 3 ( 200) nA
Rise and fall time
Anstiegs- und Abfallzeit
(IC = 1 mA, VCC = 5 V, RL = 1 k)
tr, tf11 µs
Parameter Symbol Values Unit
Bezeichnung Symbol Werte Einheit
SFH
314
SFH
314 FA
2007-04-03 4
Version 1.0 SFH 314, SFH 314 FA
Grouping (TA = 25 °C, λ = 950 nm)
Gruppierung
Group Min Photocurrent Max
Photocurrent
Typ Photocurrent Rise and fall time
Gruppe Min Fotostrom Max Fotostrom Typ Fotostrom Anstiegs- und
Abfallzeit
Ee = 0.5 mW/cm2,
VCE = 5 V
Ee = 0.5 mW/cm2,
VCE = 5 V
SFH 314:
EV = 1000 lx, Std.
Light A, VCE = 5 V
IC = 1 mA,
VCC = 5 V,
RL = 1 k
IPCE, min [µA] IPCE, max [µA] IPCE [µA] tr, tf [µs]
-1 630 1250 3400 8
-2 1000 2000 5400 10
-3 1600 3200 8600 12
-4 2500 13500 14
Group Collector-emitter saturation voltage
Gruppe Kollektor-Emitter Sättigungsspannung
IC = IPCEmin x 0.3, Ee = 0.5 mW/cm2
VCEsat [mV]
-1 150
-2 150
-3 150
-4 150
Note.: IPCEmin is the min. photocurrent of the specified group.
Anm.: IPCEmin ist der minimale Fotostrom der jeweiligen Gruppe.
Version 1.0 SFH 314, SFH 314 FA
2007-04-03 5
Relative Spectral Sensitivity
Relative spektrale Empfindlichkeit
SFH 314 Srel = f(λ)
Relative Spectral Sensitivity
Relative spektrale Empfindlichkeit
SFH 314 FA Srel = f(λ)
Photocurrent
Fotostrom
IPCE = f(Ee), VCE = 5 V
Photocurrent
Fotostrom
IPCE = f(VCE), Ee = Parameter
λ
OHF02332
0
rel
S
400
10
20
30
40
50
60
70
80
%
100
500 600 700 800 900 nm 1100
λ
OHF02331
0
rel
S
400 600 800 1000 1200
20
40
60
80
%
100
nm
E
OHF02339
e
PCE
Ι
10
0
-2
10
10
-1
1
10
mA
10
-3 -2
10
0
10mW/cm
2
10
-3
V
OHF02338
CE
PCE
Ι
0
10
0
-1
10 10 20 30 40 50 V 70
10
1
mA
0.5 mW
cm
2
2
cm
mW
1
2
cm
mW
0.25
0.1 mW
cm
2
2007-04-03 6
Version 1.0 SFH 314, SFH 314 FA
Photocurrent
Fotostrom
IPCE / IPCE(25°C)= f(TA), VCE = 5 V
Dark Current
Dunkelstrom
ICEO = f(VCE), E = 0
Dark Current
Dunkelstrom
ICEO = f(TA), E = 0
Collector-Emitter Capacitance
Kollektor-Emitter Kapazität
CCE = f(VCE), f = 1 MHz, E = 0
T
OHF01524
A
0
-25
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
025 50 75 100
Ι
PCE
PCE
Ι
25
C
V
OHF02341
CE
0
CEO
Ι
-2
10
10
-1
10
0
10
1
10
2
nA
10 20 30 40 50 70V
T
OHF02342
A
0
CEO
Ι
-1
10
10
0
10
1
10
2
10
3
nA
20 40 60 80 100˚C
Version 1.0 SFH 314, SFH 314 FA
2007-04-03 7
Total Power Dissipation
Verlustleistung
Ptot = f(TA)
Directional Characteristics
Winkeldiagramm
Srel = f(ϕ)
T
OHF02340
A
0
tot
P
020 40 60 80 ˚C 100
50
100
150
200
250
mW
OHF02329
02040 60 80 100 1200.40.60.81.0
100
90
80
70
60
50
0
10203040
0
0.2
0.4
0.6
0.8
1.0
ϕ
2007-04-03 8
Version 1.0 SFH 314, SFH 314 FA
Package Outline
Maßzeichnung
Dimensions in mm (inch). / Maße in mm (inch).
5.9 (0.232)
5.5 (0.217)
0.6 (0.024)
0.4 (0.016)
ø5.1 (0.201)
ø4.8 (0.189)
2.54 (0.100)
spacing
5.7 (0.224)
5.5 (0.217)
6.9 (0.272)
6.1 (0.240)
4.0 (0.157)
3.4 (0.134)
29.5 (1.161)
27.5 (1.083)
1.8 (0.071)
1.2 (0.047)
0.8 (0.031)
0.4 (0.016)
Area not flat
0.6 (0.024)
0.4 (0.016)
Cathode (Diode) Chip position
GEXY6630
Collector (Transistor)
Version 1.0 SFH 314, SFH 314 FA
2007-04-03 9
TTW Soldering
Wellenlöten (TTW)
IEC-61760-1 TTW / IEC-61760-1 TTW
OHLY0598
0
0
50 100 150 200 250
50
100
150
200
250
300
T
t
C
s
235 C
10 s
C... 260
1. Welle
1. wave
2. Welle
2. wave
5 K/s 2 K/s
ca 200 K/s
CC... 130100
2 K/s Zwangskühlung
forced cooling
Normalkurve
standard curve
Grenzkurven
limit curves
2007-04-03 10
Version 1.0 SFH 314, SFH 314 FA
Disclaimer Disclaimer
Attention please!
The information describes the type of component and
shall not be considered as assured characteristics.
Terms of delivery and rights to change design reserved.
Due to technical requirements components may contain
dangerous substances.
For information on the types in question please contact
our Sales Organization.
If printed or downloaded, please find the latest version in
the Internet.
Packing
Please use the recycling operators known to you. We
can also help you – get in touch with your nearest sales
office.
By agreement we will take packing material back, if it is
sorted. You must bear the costs of transport. For
packing material that is returned to us unsorted or which
we are not obliged to accept, we shall have to invoice
you for any costs incurred.
Components used in life-support devices or
systems must be expressly authorized for such
purpose!
Critical components* may only be used in life-support
devices** or systems with the express written approval
of OSRAM OS.
*) A critical component is a component used in a
life-support device or system whose failure can
reasonably be expected to cause the failure of that
life-support device or system, or to affect its safety or the
effectiveness of that device or system.
**) Life support devices or systems are intended (a) to be
implanted in the human body, or (b) to support and/or
maintain and sustain human life. If they fail, it is
reasonable to assume that the health and the life of the
user may be endangered.
Bitte beachten!
Lieferbedingungen und Änderungen im Design
vorbehalten. Aufgrund technischer Anforderungen
können die Bauteile Gefahrstoffe enthalten. Für weitere
Informationen zu gewünschten Bauteilen, wenden Sie
sich bitte an unseren Vertrieb. Falls Sie dieses
Datenblatt ausgedruckt oder heruntergeladen haben,
finden Sie die aktuellste Version im Internet.
Verpackung
Benutzen Sie bitte die Ihnen bekannten Recyclingwege.
Wenn diese nicht bekannt sein sollten, wenden Sie sich
bitte an das nächstgelegene Vertriebsbüro. Wir nehmen
das Verpackungsmaterial zurück, falls dies vereinbart
wurde und das Material sortiert ist. Sie tragen die
Transportkosten. Für Verpackungsmaterial, das
unsortiert an uns zurückgeschickt wird oder das wir nicht
annehmen müssen, stellen wir Ihnen die anfallenden
Kosten in Rechnung.
Bauteile, die in lebenserhaltenden Apparaten und
Systemen eingesetzt werden, müssen für diese
Zwecke ausdrücklich zugelassen sein!
Kritische Bauteile* dürfen in lebenserhaltenden
Apparaten und Systemen** nur dann eingesetzt
werden, wenn ein schriftliches Einverständnis von
OSRAM OS vorliegt.
*) Ein kritisches Bauteil ist ein Bauteil, das in
lebenserhaltenden Apparaten oder Systemen
eingesetzt wird und dessen Defekt voraussichtlich zu
einer Fehlfunktion dieses lebenserhaltenden Apparates
oder Systems führen wird oder die Sicherheit oder
Effektivität dieses Apparates oder Systems
beeinträchtigt.
**) Lebenserhaltende Apparate oder Systeme sind für
(a) die Implantierung in den menschlichen Körper oder
(b) für die Lebenserhaltung bestimmt. Falls Sie
versagen, kann davon ausgegangen werden, dass die
Gesundheit und das Leben des Patienten in Gefahr ist.
Version 1.0 SFH 314, SFH 314 FA
2007-04-03 11
Published by OSRAM Opto Semiconductors GmbH
Leibnizstraße 4, D-93055 Regensburg
www.osram-os.com © All Rights Reserved.