Parameter Min Typ Max Units Condition
Additional Parameters1 [10 to 20 MHz]
Phase Noise3 (10 to 20 MHZ) -100
-125
-140
-145
-145
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
10 kHz
Phase Noise3 (>20 to 40 MHZ) -90
-115
-130
-140
-140
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
dBc/Hz
10 Hz
100 Hz
1 kHz
10 kHz
10 kHz
G-Sensitivity 1 ppb/g Test at 10g sine vibration at 100Hz
Environmental Conditions (Designed to meet)
• Radiation Tolerant (operating): Active devices are selected from a family of product that is inherently
radiation tolerant to meet 100krad (SI) total dose
• Mechanical Shock (survive)***: MIL-STD-202, Test Method 213, Condition E (1000G, 0.5msec)
• Vibration Random (survive)***: MIL-STD-202, Test Method 214, Condition I-F (20Grms, 3 minutes/axis)
• Vibration Sine (survive)***: MIL-STD-202, Test Method 204, Condition D (20Grms, 20 minutes/axis)
Note: *** Met by design, not tested
Screening Options
Ordering Code S B
Test Inspection S-Level Screening B-Level Screening
Nondestructive Bond Pull MIL-STD-883
Method 2023
N/A
Internal Visual Per Mil-PRF-
55310 Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Internal Visual Per Mil-PRF-55310
Requirement
Stabilization Bake MIL-STD-883
Method 1008,
Condition C
150°C for 48hrs MIL-STD-883
Method 1008,
Condition C
150°C for 48hrs
Thermal Shock MIL-STD-883
Method 1011,
Condition A
0°C to 100°C for
15cycles
N/A
Temperature Cycling (1) MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
MIL-STD-883
Method 1010,
Condition A
-55°C to 85°C (2)
for 10cycles
Constant Acceleration (1) MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
MIL-STD-883
Method 2001
1000g’s (3)
Y1 Only
PIND MIL-STD-883
Method 2020,
Condition B
10g peak at 60Hz
minimum
N/A
Electrical Test Per Mil-PRF-55310 Requirement Per Mil-PRF-55310 Requirement
Burn-in (1) 85°C (2) for 240hrs 85°C (2) for 240hrs
Radiographic MIL-STD-883
Method 2012
N/A
Note:
(1) These test inspections deviate from screening requirements for class 2 oscillator in MIL-PRF-55310.
(2) The maximum operating and storage temperature of the EX-209 is +85°C. The EX-209 shall not be exposed to temperature higher
than +85°C at length of time.
(3) The design and construction of the EX-209 can withstand up to 1000g’s constant acceleration
Vectron International • 267 Lowell Road, Hudson, NH 03051 • Tel: 1-88-VECTRON-1 • http://www.vectron.com
Performance Speci cations