US300
US300 www.meas-spec.com August 2012
4/4
OUTPUT OPTIONS
Supply (V)
Code Output MIN TYP MAX
2 0 – 10mV/V (ratiometric) 2.5 5 12
3 0.5 – 4.5 V (ratiometric) 4.75 5 5.25
4 1 – 5 V 8 30
8 4 – 20 mA 9 30
Packard connector not available with mV output.
Wiring Code
Code Output +Supply -Supply +Out -Out
2 0 – 10mV/V (ratiometric) Red Black Green White
3 0.5 – 4.5 V (ratiometric) Red/Pin A Black/Pin B Green/Pin C N/A
4 1 – 5 V Red/Pin A Black/ Pin B Green/Pin C N/A
8 4 – 20 mA Red/Pin A Black/Pin B N/A N/A
ORDERING INFORMATION
US381-000005-500PG
Pressure Port (2 = 1/4-19BSP, 4 = 7/16-20UNF, 5 = 1/4-18NPT,
Options (nnnnn = Custom Drawing)
Output (2 = 0 - 10mV/V, 3 = 0.5 - 4.5V, 4 - 1 - 5V, 8 = 4 - 20mA)
Connection (1 = 2ft, 2 = 4ft, 3 = 10ft Cable, 4 = Packard)
Type (A = Absolute, G = Gage)
Pressure Range (500 = 500, 05K = 5000)
6 = 1/8-27NPT)
Model
Units (P = psi, B = Bar)
NORTH AMERICA EUROPE ASIA
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.