US300
US300 www.meas-spec.com August 2012
1/4
OEM and End User
High Accuracy
Compact Package
Wide Temperature Range
DESCRIPTION
The low cost US300 Series incorporates stainless steel isolation, and provides a wide choice of
standard pressure ranges and electrical outputs in a very compact package. This product uses MEAS’
UltraStable technology that provides stability over a wide temperature range, performance previously
available only in much higher priced sensors. The modular design is adaptable to a wide variety of pressure
ports and electrical connectors. Standard outputs include 0 to 10mV/V, 0.5 to 4.5V ratiometric, 1 to 5V regulated
and 4 to 20mA current loop.
FEATURES APPLICATIONS
±0.1% Accuracy Refrigeration and HVAC Controls
-40°C to +105°C Operating
Temperature Range Compressed Gases
100% Stainless Steel 316L Isolation Process Control
Wide Variety of Pressure Ranges and
Electrical Outputs Water Pressure Monitoring
Low Cost and Compact Package
UltraStable™ Technology
STANDARD RANGES
Range psig psia Range Barg Bara
0 to 15 0 to 1
0 to 30 0 to 2
0 to 50
0 to 5
0 to 100 0 to 7
0 to 10
0 to 300 0 to 20
0 to 500 0 to 35
0 to 1k 0 to 70
0 to 100
0 to 3k 0 to 200
0 to 5k 0 to 350
US300
US300 www.meas-spec.com August 2012
2/4
PERFORMANCE SPECIFICATIONS
Ambient Temperature: 25°C (unless otherwise specified)
PARAMETERS MIN TYP MAX UNITS NOTES
Offset -1 ±0.5 1 %Span 1
Span -1 ±0.5 1 %Span 1,2
Accuracy (combined non linearity, hysteresis, and repeatability) -0.15 ±0.1 0.15 %Span 2,3
Output Resistance (0 -10mV/V) 4 12 30 kΩ 1, 2
Temperature Error – Offset -1.5 ±0.75 1.5 %Span 4
Temperature Error – Span -1.5 ±0.75 1.5 %Span 4
Supply Current (0 – 10mV/V) 1 2 mA 2
Supply Current (0.5 – 4.5V, 1 – 5V) 2.5 3 5 mA
Long Term Stability (1 year) -0.1 0.1 %Span
Frequency Response (-3dB) 1 kHz
Compensated Temperature -20 +85 °C
Operating Temperature -40 +105 °C 7
Storage Temperature -40 +125 °C
Proof Pressure 3X Rated
Burst Pressure 4X Rated
Vibration ±20 g 5
Shock (11ms) 100 g 6
Pressure Cycles (Zero to Full Scale) 1 Million
Isolation Resistance (50Vdc) 50 MΩ
Weight grams
Media Compatibility All Materials Compatible with 316 Stainless Steel
Environmental Protection IP 67 (Cable Version)
For custom configurations, consult factory.
Notes
1. Output loading may affect performance.
2. For low level (100mV) sensors span is ratiometric to supply (10mV/volt output).
3. Best fit straight line.
4. For pressures > 1k psi, 0.25% Best fit straight line.
5. Per MIL-STD-810C, Procedure 514.2, Figure 514.2-2, Curve L.
6. 1/2 sine per MIL-STD 202F Method 213B condition A.
7. 80°C max temperature for cable version.
US300
US300 www.meas-spec.com August 2012
3/4
DIMENSIONS
US300
US300 www.meas-spec.com August 2012
4/4
OUTPUT OPTIONS
Supply (V)
Code Output MIN TYP MAX
2 0 – 10mV/V (ratiometric) 2.5 5 12
3 0.5 – 4.5 V (ratiometric) 4.75 5 5.25
4 1 – 5 V 8 30
8 4 – 20 mA 9 30
Packard connector not available with mV output.
Wiring Code
Code Output +Supply -Supply +Out -Out
2 0 – 10mV/V (ratiometric) Red Black Green White
3 0.5 – 4.5 V (ratiometric) Red/Pin A Black/Pin B Green/Pin C N/A
4 1 – 5 V Red/Pin A Black/ Pin B Green/Pin C N/A
8 4 – 20 mA Red/Pin A Black/Pin B N/A N/A
ORDERING INFORMATION
US381-000005-500PG
Pressure Port (2 = 1/4-19BSP, 4 = 7/16-20UNF, 5 = 1/4-18NPT,
Options (nnnnn = Custom Drawing)
Output (2 = 0 - 10mV/V, 3 = 0.5 - 4.5V, 4 - 1 - 5V, 8 = 4 - 20mA)
Connection (1 = 2ft, 2 = 4ft, 3 = 10ft Cable, 4 = Packard)
Type (A = Absolute, G = Gage)
Pressure Range (500 = 500, 05K = 5000)
6 = 1/8-27NPT)
Model
Units (P = psi, B = Bar)
NORTH AMERICA EUROPE ASIA
Measurement Specialties
45738 Northport Loop West
Fremont, CA 94538
Tel: 1-800-767-1888
Fax: 1-510-498-1578
Sales: pfg.cs.amer@meas-spec.com
Measurement Specialties
(Europe), Ltd.
26 Rue des Dames
78340 Les Clayes-sous-Bois, France
Tel: +33 (0) 130 79 33 00
Fax: +33 (0) 134 81 03 59
Sales: pfg.cs.emea@meas-spec.com
Measurement Specialties
(China), Ltd.
No. 26 Langshan Road
Shenzhen High-Tech Park (North)
Nanshan District, Shenzhen 518057
China
Tel: +86 755 3330 5088
Fax: +86 755 3330 5099
Sales: pfg.cs.asia@meas-spec.com
The information in this sheet has been carefully reviewed and is believed to be accurate; however, no responsibility is assumed for
inaccuracies. Furthermore, this information does not convey to the purchaser of such devices any license under the patent rights to the
manufacturer. Measurement Specialties, Inc. reserves the right to make changes without further notice to any product herein. Measurement
Specialties, Inc. makes no warranty, representation or guarantee regarding the suitability of its product for any particular purpose, nor does
Measurement Specialties, Inc. assume any liability arising out of the application or use of any product or circuit and specifically disclaims
any and all liability, including without limitation consequential or incidental damages. Typical parameters can and do vary in different
applications. All operating parameters must be validated for each customer application by customer’s technical experts. Measurement
Specialties, Inc. does not convey any license under its patent rights nor the rights of others.