Cutler-Hammer Molded Case Circuit Breakers 10-225 Amperes 12-22 January 2001 Vol. 1,Ref. No. [0488] F-Frame Table 12-35. Type FD Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. 600V AC Maximum, 250V DC Cont. Ampere 14 kAIC 600V AC Rating @40C Type FOB (Includes Terminals on Load End Only) 3-Pole 2-Pole 4-Pole Catalog Number FDB2010 FDB2015 FOB2020 FDB2025 FDB2030 FDB2035 FDB2040 FDB2045 FDB2050 FDB2060 FDB2070 FDB2080 FDB2090 FDB2100 FDB2110 FDB2125 FDB2150 -- -- -- 10(R) 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 Catalog Number Price U.S. $ 435. 435. 435. 435. 435. 435. 435. 393. 435. 435. 565. 565. 565. 565. 1,260. 1,260. 1,260. -- -- -- FDB3010 FDB3015 FDB3020 FDB3025 FDB3030 FDB3035 FDB3040 FDB3045 FDB3050 FDB3060 FDB3070 FDB3080 FDB3090 FDB3100 FDB3110 FDB3125 FDB3150 -- -- -- Price U.S. $ Catalog Number FDB4010 FDB4015 FDB4020 FOB4025 FDB4030 FDB4035 FDB4040 FDB4045 FDB4050 FDB4060 FDB4070 FDB4080 FDB4090 FDB4100 FDB4110 FDB4125 FDB4150 -- -- -- -- 570. 570. 570. 570. 570. 570. 570. 570. 570. 570. 695. 695. 695. 695. 1,565. 1,565. 1,565. -- -- 277V AC Maximum, 600V AC Maximum, 250V DC 125V DC 25 kAIC @ 277V AC 25 kAIC @ 480V AC Type FD (Includes Terminals on Load End Only) 1-Pole Price U.S. S 910. 910. 910. 910. 910. 910. 910. 910. 910. 1,110. 1,110. 1,110. 1,110. 1,110. 2,495. 2,495. 2,495. -- -- -- Catalog Number FD1010 FD1015S FD1020* FD1025 FD1030 FD1035 FD1040 FD1045 FD1050 FD1060 FD1070 FD1080 FD1090 FD1100 FD1110 FD1125 FD1150 -- -- -- 2-Pole Price U.S. S Catalog Number 299. -- 299. FD2015 299. F02020 299. FD2025 299. FD2030 299. FD2035 299. FD2040 299. FD2045 299. FD2050 299. FD2060 335. FD2070 335. FD2080 335. FD2090 335. FD2100 760. FD2110 760. FD2125 760. FD2150 -- FD2175 -- FD2200 -- FD2225 3-Pole Price U.S. S Catalog Number 4-Pole Price U.S.S -- 735. 735. 735. 735. 735. 735. 735. 735. 735. 855. 855. 855. 855. 1,915. 1,915. 1,915. 1,920. 1,920. 1,920. FD3015 FD3020 FD3025 FD3030 FD3035 FD3040 FD3045 FD3050 FD3060 FD3070 FD3080 FD3090 FD3100 FD3110 FD3125 FD3150 FD3175 FD3200 FD3225 865. 865. 865. 865. 865. 865. 865. 865. 865. 975. 975. 975. 975. 2,205. 2,205. 2,205. 2,205. 2,205. 2,205. Catalog Number -- FD4015 FD4020 FD4025 FD4030 FD4035 FD4040 FD4045 FD4050 FD4060 FD4070 FD4080 FD4090 FD4100 FD4110 FD4125 FD4150 FD4175 FD4200 FD4225 Price U.S.S 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,360. 1,495. 1,495. 1,495. 1,495. 3,080. 3,080. 3,080. 3,080. 3,080. 3,080. CO Not UL listed. 5 kAIC interrupting rating. <& UL listed for SWD applications, see NEC Article 240-83 (d). Note: Instruction Leaflet/FRED Number 29C101 Table 12-36. Types HFD and FDC Thermal-Magnetic Circuit Breakers with Non-interchangeable Trip Units Max. 277V AC Maximum, 600V AC Maximum, 250V DC 125V DC Cont. Ampere 65 kAIC @ 277V AC 65 kAIC @ 480V AC Rating Type HFD @40C (Includes Terminals on Load End Only) 2-Pole 1-Pole Catalog Number 15 20 25 30 35 40 45 50 60 70 80 90 100 110 125 150 175 200 225 * HFD1015 A1 HFD1020(R) HFD1025 HFD1030 HFD1035 HFD1040 HFD1045 HFD1050 HFD1060 HFD1070 HFD1080 HFD1090 HFD1100 HFD1110 HFD1125 HFD1150 -- -- -- Catalog Number Price U.S.S HFD2015 HFD2020 HFD2025 HFD2030 HFD2035 HFD2040 HFD2045 HFD2050 HFD2060 HFD2070 HFD2080 HFD2090 HFD2100 HFD2110 HFD2125 HFD2150 HFD2175 HFD2200 -- HFD2225 366. 366. 366. 366. 366. 366. 366. 366. 366. 427. 427. 428. 427. 1,001. 1,001. 1,005. -- -- 600V AC Maximum, 250V DC 100 kAIC @ 480V AC Type FDC Current Limiting (Includes Terminals on Load End Only) 3-Pole Price U.S.S 885. 885. 885. 885. 885. 885. 885. 885. 885. 1,130. 1,130. 1,130. 1,130. 2,510. 2,510. 2,510. 2,720. 2,720. 2,720. Catalog Number HFD3015 HFD3020 HFD3025 HFD3030 HFD3035 HFD3040 HFD3045 HFD3050 HFD3060 HFD3070 HFD3080 HFD3090 HFD3100 HFD3110 HFD3125 HFD3150 HFD3175 HFD3200 HFD3225 4-Pole Price U.S/S 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 1,140. 3,120. 3,120. 3,120. 3,120. 3,120. 3,120. Catalog Number HFD4015 HFD4020 HFD4025 HFD4030 HFD4035 HFD4040 HFD4045 HFD4050 HFD4060 HFD4070 HFD4080 HFD4090 HFD4100 HFD4110 HFD4125 HFD4150 HFD4175 HFD4200 HFD4225 2-Pole Price U.S. S 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 1,940. 2,445. 2,445. 2,445. 2,445. 4,405. 4,405. 4,405. 4,370. 4,370. 4,370. Catalog Number FDC2015 FDC2020 FDC2025 FDC2030 FDC2035 FDC2040 FDC2045 FDC2050 FDC2060 FDC2070 FDC2080 FDC2090 FDC2100 FDC2110 FDC2125 FDC2150 FDC2175 FDC2200 FDC2225 3-Pole Price U.S.S 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,325. 1,690. 1,690. 1,690. 1,690. 3,780. 3,780. 3,780. 3,780. 3,780. 3,780. Catalog Number FDC3015 FDC3020 FDC3025 FDC3030 FDC3035 FDC3040 FDC3045 FDC3050 FDC3060 FDC3070 FDC3080 FDC3090 FDC3100 FDC3110 FDC3125 FDC3150 FDC3175 FDC3200 FDC3225 4-Pole Price U.S.S 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 1,710. 2,095. 2,095. 2,095. 2,095. 4,685. 4,685. 4,685. 4,685. 4,685. 4,685. Catalog Number FDC4015 FDC4020 FDC4025 FDC4030 FDC4035 FDC4040 FDC4045 FDC4050 FDC4060 FDC4070 FDC4080 FDC4090 FDC4100 FDC4110 FDC4125 FDC4150 FDC4175 FDC4200 FDC4225 Price U.S.S 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 2,910. 3,600. 3,600. 3,600. 3,600. 6,610. 6,610. 6,610. 6,610. 6,610. 6,610. (R) UL listed for SWD applications, see NEC Article 240-83(d). Note: Instruction Leaflet/FRED Number 29C101 Discount Symbol. E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CB-2 CAT.200.01.T.E 12-2 Product Line Overview January 2001 Vol. 1, Ref. No. [0468] Product Line Description Cutler-Hammer Molded Case Circuit Breakers are designed to provide circuit protection for low voltage distribution systems. They are described by NEMA as, ". . . a device for closing and interrupting a circuit between separable contacts under both normal and abnormal conditions," and furthermore as, ". . . a breaker assembled as an integral unit in a supporting and enclosing housing of insulating material." The NEC describes them as, "A device designed to open and close a circuit by non-automatic means, and to open the circuit automatically on a predetermined overload of current, without injury to itself when properly applied within its rating." 12 So designed, Cutler-Hammer circuit breakers protect conductors against overloads and conductors and connected apparatus, such as motors and motor starters, against short circuits. In low voltage distribution systems, there are many varied applications of molded case circuit breakers. Cutler-Hammer offers the most comprehensive family of molded case circuit breakers in the industry. This family of circuit breakers includes: Thermal Magnetic Trip Breakers Electronic rms Trip Breakers Molded Case Switches Motor Circuit Protectors Current Limiting Breakers Special Application Breakers World Breakers Special Calibration All circuit breaker cases are molded from glass-polyester which does not support the growth of fungus. Any parts which are susceptible to the growth of fungus will require special treatment. 20% Adder 50C Calibration Add suffix V to Catalog Number for complete breaker, listed above, when ordering listed ampere ratings for breakers to be used in 50C ambients. Standards and Certifications Molded case circuit breakers are designed to conform with the following standards: Suffix J01 Fungus Treated $325. + 20% Adder Freeze-Tested Circuit Breakers The circuit breakers may be ordered with freeze testing. This option uses special lubrication and mechanical operation is verified at -40C. Suffix F01 Freeze Tested 20% Adder Marine Applications F-Frame circuit breakers can be supplied to meet the following marine specifications: U.S. Coast Guard CFR 46 ABS -- American Bureau of Shipping IEEE 45 These specifications generally require molded case circuit breakers to be supplied with 50C ambient calibration, special nameplating, and plug-in adapter kits. When plug-in adapter kits are used, no terminals need be supplied. Circuit breakers can also be supplied to meet UL489 Supplement SA (Marine Use) and UL489 Supplement SB (Naval Use). UL489 Supplement SA applies to vessels over 65 feet in length. Requirements include 40C ambient calibration, special labeling, and no use of aluminum conductors or terminals. Suffix H08 "Marine" Special non-UL-listed calibrations are available for certain ambient temperatures other than 40C and for frequencies other than 50/60 Hz or DC. Reduced interrupting ratings will apply for 400 Hz applications. Maximum thermal calibration is limited to 135A at 400 Hz. Suffix H01 400 Hz Moisture-Fungus Treatment 10% Adder UL 489 Supplement SB requires 50C ambient calibration, vibration testings, special nameplating and no use of aluminum conductors or terminals. Suffix H09 "Naval" 10% Adder Underwriters Laboratories, Inc., Standard UL489, Molded Case Circuit Breakers and Circuit Breaker Enclosures National Electrical Manufacturers Association Standards Publication No. AB1-1993, Molded Case Circuit Breakers Australian Standard AS 2184, Molded Case Circuit Breakers British Standards Institution Standard BS 4752: Part 1, Switchgear and Control Gear Part 1: Circuit Breakers Canadian Standards Association Standard C22.2 No. 5, Service Entrance and Branch Circuit Breakers International Electrotechnical Commission Recommendations IEC 157-1, Circuit Breakers Japanese T-Mark Standard Molded Case Circuit Breakers South African Bureau of Standards, Standard SABS 156, Standard Specification for Molded Case Circuit Breakers Swiss Electro-Technical Association Standard SEV 157-1, Safety Regulations for Circuit Breakers Union Technique de l'Electricite Standard NF C 63-120, Low Voltage Switchgear and Control Gear Circuit Breaker Requirements Verband Deutscher Elektrotechniker (Association of German Electrical Engineers) Standard VDE 0660, Low Voltage Switchgear and Control Gear, Circuit Breakers Conformance with these standards satisfies most local and international codes, assuming user acceptability and simplified application. Molded case circuit breakers equal or exceed Federal Specification Classification W-C-375b requirements for the particular class associated with the circuit breaker frame being considered. Note: For further information, see Circuit Breaker, CD-ROM SA.74A.01.T.E. For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E 12 Product Line Overview January 2001 Vol. 1, Ref. No. [0469] Quick Reference Table 12-1. Industrial Circuit Breakers Circuit Cont. Breaker Amp. Type Rating @ 40C No. Volts Poles AC DC Type Federal Spec. of Trip W-C375b UL Listed Interrupting Ratings rms Symmetrical Amperes 120 Page Number DC AC Ratings Volts 120/240 240 277 480 600 125 250 125/250 -- -- -- -- 14,000 -- -- -- -- 14,000 12-9 12-9 14,000 -- 14,000 -- 14,000 -- -- -- -- -- -- -- -- 14,000 -- 14,000 -- -- 12-9 12-9 12-9 12-9 12-9 12-9 -- -- -- -- 11-14 11-14 -- 14,000 12-11 12-11 G-Frame GB GB 15 - 100 1 15 - 100 2, 3 120 240 125 N.I.T. 125/250 11a 10b, 11b, 12b, 14b, 15b 65,000 -- -- -- GHB GHB GHB GHB HGHB GQ 15 - 100 15 - 100 15 - 100 15 - 100 15 - 30 15 - 20 1 2, 3 1 2, 3 1 1 120 240 277 277/480 277 277 N.I.T. 125 125/250 125 125/250 125 -- 11a 10b, 11b, 12b, 14b, 15b 12c, 13a, 13b 65,000 -- -- -- 65,000 65,000 GHBS GBHS 15 - 30 15 - 20 1, 2 1, 2 277/480 347/600 -- -- -- -- GC GC 15 - 100 1 15 - 100 2, 3 120 240 125 N.I.T. 125/250 GD GD 15 - 50 2 15 - 100 3 480 480 GHC GHC GHC GHC HGHC 15 - 100 15 - 100 15 - 100 15 - 100 15 - 30 120 240 277 277/480 277 1 2, 3 1 2, 3 1 -- -- 65,000 -- -- 65,000 -- -- -- -- -- -- 14,000 14,000 25,000 14,000 -- -- -- 14,000 -- -- -- -- -- -- -- -- 65,000 65,000 -- -- -- -- 14,000 -- -- -- -- -- 10,000 -- 11a 10b, 11b, 12b, 14b, 15b 65,000 -- -- -- -- -- 65,000 -- -- -- -- -- 125/250 N.I.T. 250 N.I.T. 13b 13b -- -- -- -- 65,000 -- 65,000 -- 14,000 -- 22,000 -- -- -- -- 10,000 10,000 -- 12-8 12-8 125 N.I.T. 125/250 125 125/250 125 12c, 13a 13b 12c, 13a 13b 65,000 -- -- -- 65,000 -- -- -- -- -- -- 65,000 -- -- -- -- -- -- 14,000 -- 14,000 -- 14,000 -- 14,000 -- -- -- -- -- 12-11 12-11 12-11 12-11 12-11 250 -- -- 35,000 -- -- -- -- N.I.T. -- -- -- -- -- -- -- -- 14,000 14,000 25,000 -- -- -- -- -- 14,000 -- -- -- -- 14,000 -- 14,000 -- New E125 Frame E125B 15 - 125 1 277 2, 3, 4 480 N.I.T. -- 25,000 18,000 -- -- 25,000 -- 18,000 -- 35,000 -- 10,000 -- -- -- 10,000 -- 12-16 E125E 15 - 125 2, 3, 4 600Y/347 250 N.I.T. -- -- 25,000 18,000 10,000 10,000 -- 12-16 E125S 15 - 125 1 347 250 2, 3, 4 600Y/347 N.I.T. N.I.T. -- -- 100,000 -- -- -- 85,000 35,000 -- -- 35,000 -- -- 85,000 -- 35,000 22,000 -- 35,000 -- 12-16 E125H 15 - 125 1 347 250 2, 3, 4 600Y/347 N.I.T. -- -- 200,000 -- -- -- 100,000 65,000 -- -- 42,000 -- -- 100,000 -- 65,000 25,000 -- 42,000 -- 12-17 65,000 -- 100,000 -- 200,000 -- -- -- -- 12-21 12-21 12-21 10,000 -- -- -- 10,000 -- 12-21 12-21 F-Frame ED EDH EDC 100 - 225 2, 3 100 - 225 2, 3 100 - 225 2, 3 240 240 240 125 125 125 N.I.T. 12b 14b 1 -- -- -- -- -- -- EHD EHD 15 - 100 1 15 - 100 2, 3 277 480 125 250 N.I.T. 13a 13b -- -- -- -- -- 14,000 18,000 -- -- -- 14,000 -- FDB FDB 15 - 150 2, 3 15 - 150 4 600 600 250 250 N.I.T. 18a -- -- -- -- 18,000 -- 18,000 -- 14,000 14,000 -- 14,000 14,000 -- 10,000 -- 10,000 -- 12-22 12-22 FD FD FD 15 - 225 1 15 - 225 2, 3 15 - 225 4 277 600 600 125 250 250 N.I.T. 13a 22a -- -- -- -- -- -- -- 25,000 65,000 -- 65,000 -- -- -- 10,000 -- -- 25,000 18,000 -- 10,000 -- 25,000 18,000 -- 10,000 -- 12-22 12-22 12-22 HFD HFD HFD 15 - 225 1 15 - 225 2,3 15 - 225 4 277 600 600 125 250 250 N.I.T. 13a 22a -- -- -- -- -- -- -- 65,000 100,000 -- 100,000 -- -- -- 10,000 -- -- 65,000 25,000 -- 22,000 -- 65,000 25,000 -- 22,000 -- 12-22 12-22 12-22 FDC FDC 15 - 225 2, 3 15 - 225 4 600 600 250 250 N.I.T. 24a -- -- -- -- 200,000 -- 200,000 -- 100,000 35,000 -- 100,000 35,000 -- 22,000 -- 22,000 -- 12-22 12-22 63 - 250 2, 3, 4 600 63 - 250 2, 3, 4 600 63 - 250 2, 3, 4 600 250 250 250 I.T I.T I.T -- -- -- -- -- -- -- -- -- 65,000 -- 85,000 -- 100,000 -- 25,000 18,000 -- 35,000 18,000 -- 65,000 25,000 -- 10,000 -- 22,000 -- 22,000 -- 12-28 12-28 12-28 -- -- -- -- -- -- 10,000 -- 10,000 -- 10,000 -- New J250 Frame J250E J250S J250H N.I.T. is non-interchangeable trip unit and I.T. is interchangeable trip unit. Two-pole circuit breaker, or two poles of three-pole circuit breaker at 250V DC. Not defined in W-C-375b. CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog Cutler-Hammer Molded Case Circuit Breakers 10-225 Amperes January 2001 12-19 Vol. 1, Ref. No. [0485] F-Frame Product Description F-Frame Contents Description Page Product Description 12-19 Technical Data and Specifications 12-19 Dimension/Weights 12-20 Product Selection .. 12-20 * All F-Frame Circuit Breakers are HACR rated. * All circuit breakers 10 through 50 amperes are suitable for HID (high intensity discharge) use. * All F-Frame circuit breakers are suitable for reverse feed use. Typical F-Frame Breaker Technical Data and Specifications Table 12-28. UL489 Interrupting Capacity Ratings Circuit Breaker Type Number of Poles ED EDH EDC EHD Interrupting Capacity (Symmetrical Amperes) (kA) Volts DC & Volts AC (50/60 Hz) 240 277 2,3 2,3 2,3 65 100 200 -- 1 2,3 18 FOB 2,3,4 18 FD 1 2,3,4 HFD 1 2,3,4 100 FDC 2,3,4 200 480 -- 600 125 250 @(R) -- 10 10 -- 10 10 14 -- 14 _ 14 14 25 18 10 10 65 -- 10 10 25 65 10 -- 65 25 100 35 22 -- 22 (c) DC ratings apply to substantially non-inductive circuits. (R) 2-pole circuit breaker, or two poles of 3-pole circuit breaker. (R) Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA. Table 12-29. IEC 157-1 (PI) Interrupting Capacity Ratings (P1) Circuit Breaker Type Number of Interrupting Capacity (Symmetrical Amperes) (kA) Poles Volts AC (50/60 Hz) Volts DC A ED EDH EDC 2,3 FOB FD 220, 240 380,415 440 500 125 250 @(R) -- 10 10 10 -- 14 -- 10 65 100 200 -- 2,3,4 18 14 1 2,3,4 25 65 HFD 1 2,3,4 65 100 65 65 25 FDC 2,3,4 200 100 100 35 2,3 2,3 -- 14 10 35 35 18 10 10 22 -- 22 (R) DC ratings apply to substantially non-inductive circuits. (R) 2-pole circuit breaker, or two poles of 3-pole circuit breaker. (c) Time constant is 3 milliseconds minimum at 10 kA and 8 milliseconds minimum at 22 kA. CAT.200.01.T.E For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog F.T.N Cutler-Hammer Molded Case Circuit Breakers 10-225 Amperes 12-20 January 2001 Vol. 1, Ref. No. [0486J .. f-i -i F-Frame Dimensions/Weights Table 12-30. Dimensions in Inches (mm) Number of Poles Width 1 1.375(35) 2 2.75 (70) Depth 6(152) 6(152) Breaker Type 3.375 (86) 3.375 (86) 6(152) 6(152) 4.125(105) 5.5(140) 3 4 Table 12-31. Approximate Shipping Weight, Lbs. (Kg) Height 3.375 (86) 3.375 (86) Number of Poles 1 2 3 4 ED, EDH, EDC -- 3(1.361) 4.5(2.041) -- EHD, FOB, FD, HFD, FDC 2 (.907) 3(1.361) 4.5(2.041) 6(2.721) Product Selection This information is presented only as an aid to understanding Catalog Numbers. It is not to be used to build Catalog Numbers for circuit breakers or trip units. Table 12-32. Circuit Breaker Catalog Numbering System FDC 3 100 L J Circuit Breaker Type EHD Number of Poles 1 2 3 4 FOB FD HFD FDC = 1 Pole = 2 Poles = 3 Poles = 4 Poles Trip Ar Suffix E EH K L S V W Y Z 010 015 020 025 030 035 045 050 060 070 080 = = = = = = = = = 100% Protected (4-Pole only) Neutral Pole 50% Protected (4-Pole only) High Magnetic Molded Case Switch Line and Load Terminals Stainless Steel Terminals 50C Calibration Without Terminals Line Terminals Only Aluminum Terminals (< 100 Amperes) 090 100 110 125 150 175 (FD, HFD, FDC, 2-, 3-, 4-Pole Only) 200 (FD,HFD, FDC, 2-, 3-, 4-Pole Only) 225 (FD,HFD, FDC, 2-, 3-, 4-Pole Only) 200 Circuit Breaker Type ED EDH EDC Number of Poles 2 = 2-Pole 3 = 3-Pole Suffix L = Line and Load Terminals W = Without Terminals Y = Line Terminals Only Z = Aluminum Terminals (100 Amperes) X E:T*M For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CAT.200.01.T.E Cutler-Hammer Molded Case Circuit Breakers 10-225 Amperes January 2001 12-23 Vol. 1, Ref. No. I0489] F-Frame Table 12-37. Molded Case Switches Molded Case Switches Molded Case Switches are used as compact switches in applications requiring high current switching capabilities. Molded case switches are constructed of circuit breaker components and are of the high instantaneous automatic type. Molded case switches are listed in accordance with Underwriters Laboratories, Inc., Standard UL 1087. Line and Load Terminals Line and Load Terminals provide wire connecting capabilities for specific ranges of continuous current ratings and wire types. Except as noted, terminals comply with Underwriters Laboratories, Inc., Standards UL486A and UL486B. Unless otherwise specified, F-Frame circuit breakers are factory equipped with load terminals only. Ordering Information F-Frame circuit breakers and molded case switches have load terminals only as standard equipment. When standard line-end terminals (same as standard load-end terminals) are required, add Suffix L to the circuit breaker Catalog Number. When nonstandard or optional line and/or load terminals are required, order by style number. Specify if factory installation is required. Maximum Continuous Ampere Rating @40C 480V AC Maximum, 250V DC 600V AC Maximum, 250V DC Complete Circuit Breaker with Load Side Terminals Only Complete Circuit Breaker with Load Side Terminals Only Catalog Number Catalog Number Price U.S. S 2-Pole 100 EHD2100K 476. FD2100K FD2150K FD2225K 535.00 1,135.00 1,135.00 EHD3100K 570. FD3100K 665.00 1,240.00 1,190.00 150 225 3-Pole 100 150 225 FD3150K FD3225K 4-Pole 100 150 225 FD4100K E 930.00 1,735.00 1,665.00 -- FD4150K FD4225K Note: Molded Case Switches may open above 1800 amperes. Note: Instruction Leaflet/FRED Number 29C101 Table 12-38. Line and Load Terminals Maximum Breaker Amperes Terminal Body Material Wire Type AWG Wire Range Metric Wire Range mm2 Package of 3 Terminals Catalog Number Price U.S. $ Standard Pressure Type Terminals 20 (END) 100 225 Steel Steel Aluminum Cu/AI Cu/AI Cu/AI 14-10 14-1/0 14-4/0 2.54 2.5- 50 25 - 95 3T20FB (c) 3T100FB 3TA225FD 6.10 89.00 Cu/AI Cu/AI Cu Cu/AI 14-4 14-1/0 4-4/0 6 - 300 kcmil 2.5- 25 2.5- 50 25 - 95 16 -150 3TA50FB (R) 3TA100FD 3T150FB 3TA225FDK i 6.10 6.10 6.10 89.00 6.10 Optional Pressure Terminals 50 100 200 225 Aluminum Aluminum Stainless Steel Aluminum (R) Not for use with ED, EDH, EDC breakers. (R) Includes terminal shield kit. Adds approximately 3 inches (76.2) to breaker height. Available for use on 3-pole breaker only. Discount Symbol. CAT.200.01.T.E Price U.S. $ For more information contact Cutler-Hammer at: www.ch.cutler-hammer.com/catalog CB-2 E:t>N