60-70MT..KB Series
2
Bulletin I27500 rev. A 05/03
www.irf.com
ELECTRICAL SPECIFICATIONS
Voltage Ratings
Voltage VRRM , maximum repetitive VRSM , maximum non- IRRM max.
Type number Code peak reverse voltage repetitive peak rev. voltage @ TJ max.
V V mA
80 800 900
100 1000 1100
60-70MT..KB 120 1200 1300 10
140 1400 1500
160 1600 1700
IO Maximum DC output current 60 (75) 70 (90) A 120° Rect conduction angle
@ Case temperature 85 (61) 85 (57) °C
IFSM Maximum peak, one-cycle forward, 420 480 A t = 10ms No voltage
non-repetitive surge current 440 500 t = 8.3ms reapplied
350 400 t = 10ms 100% VRRM
370 420 t = 8.3ms reapplied Initial TJ = TJ max.
I2t Maximum I2t for fusing 870 1150 A2s t = 10ms No voltage
790 1050 t = 8.3ms reapplied
610 800 t = 10ms 100% VRRM
560 730 t = 8.3ms reapplied
I2√t Maximum I2√t for fusing 8700 11300 A2√s t = 0.1 to 10ms, no voltage reapplied
VF(TO)1 Low level value of threshold voltage 0.85 0.86 V (16.7% x π x IF(AV) < I < π x IF(AV)), @ TJ max.
VF(TO)2 High level value of threshold voltage 1.07 1.08 (I > π x IF(AV)), @ TJ max.
rf1 Low level value of forward slope resistance 8.04 7.35 mΩ (16.7% x π x IF(AV) < I < π x IF(AV)), @ TJ max.
rf2 High level value of forward slope resistance 7.08 6.53 (I > π x IF(AV)), @ TJ max.
VFM Maximum forward voltage drop 1.75 1.55 V Ipk = 100A, TJ = 25°C, tp = 400µs single junction
VINS RMS isolation voltage 4000 4000 V TJ = 25°C, all terminal shorted
f = 50Hz, t = 1s
Parameter 60MT.KB 70MT.KB Units Conditions
Forward Conduction
Thermal and Mechanical Specifications
TJ Max. junction operating temperature range -40 to 150 °C
Tstg Max. storage temperature range -40 to 150 °C
RthJC Max. thermal resistance, junction to case 0.37 0.29 K/W DC operation per module
2.22 1.75 DC operation per junction
0.40 0.34 120° Rect condunction angle per module
2.42 2.01 120° Rect condunction angle per junction
RthCS Max. thermal resistance, case to heatsink 0.03 K/W Per module
Mounting surface smooth, flat and greased
T Mounting torque ± 10% to heatsink 4 to 6 Nm
to terminal 3 to 4
wt Approximate weight 176 g
Parameter 60MT.KC 70MT.KC Units Conditions
A mounting compound is recommended and
the torque should be rechecked after a
period of 3 hours to allow for the spread of the
compound. Lubricated threads.
http://store.iiic.cc/