NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
1
REV 1.4
08/2009
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Features
High Performance:
Single Pulsed RAS Interface
Fully Synchronous to Positive Clock Edge
Four Banks controlled by BA0/BA1 (Bank Select)
Programmable CAS Latency: 2, 3
Programmable Burst Length: 1, 2, 4, 8 or full page
Programmable Wrap: Sequential or Interleave
Multiple Burst Read with Single Write Option
Automatic and Controlled Precharge Command
Dual Data Mask for byte control (x16)
Auto Refresh (CBR) and Self Refresh
Suspend Mode and Power Down Mode
Standard Power operation
Random Column Address every CK (1-N Rule)
Single Power Supply, either 3.3V
LVTTL compatible
Packages: TSOP-Type II
Lead-free & Halogen-free product available
Description
The NT5SV8M16FS, and NT5SV8M16FT are four-bank Syn-
chronous DRAMs organized as 2Mbit x 16 I/O x 4 Bank.
These synchronous devices achieve high-speed data trans-
fer rates of up to 166MHz by employing a pipeline chip archi-
tecture that synchronizes the output data to a system clock.
The device is designed to comply with all JEDEC standards
set for synchronous DRAM products, both electrically and
mechanically. All of the control, address, and data input/out-
put (I/O or DQ) circuits are synchronized with the positive
edge of an externally supplied clock.
RAS, CAS, WE, and CS are pulsed signals which are exam-
ined at the positive edge of each externally applied clock
(CK). Internal chip operating modes are defined by combina-
tions of these signals and a command decoder initiates the
necessary timings for each operation. A fifteen bit address
bus accepts address data in the conventional RAS/CAS mul-
tiplexing style. Twelve addresses (A0-A11) and two bank
select addresses (BA0, BA1) are strobed with RAS. Nine col-
umn addresses (A0-A8) plus bank select addresses and A10
are strobed with CAS.
Prior to any access operation, the CAS latency, burst length,
and burst sequence must be programmed into the device by
address inputs A0-A11, BA0, BA1 during a mode register set
cycle. In addition, it is possible to program a multiple burst
sequence with single write cycle for write through cache
operation.
Operating the four memory banks in an interleave fashion
allows random access operation to occur at a higher rate
than is possible with standard DRAMs. A sequential and gap-
less data rate of up to 166MHz is possible depending on
burst length, CAS latency, and speed grade of the device.
Auto Refresh (CBR) and Self Refresh operation are sup-
ported.
Maximum Operating Speed
CAS
Latency
PC166
(6K/6KI)
PC133
(75B/75BI)
36 7.5 ns
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
2
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Nanya Technology Corporation
Hwa Ya Technology Park 669
Fu Hsing 3rd Rd., Kueishan,
Taoyuan, 333, Taiwan, R.O.C.
Tel: +886-3-328-1688
Please visit our home page for more information: www.nanya.com
Ordering Information
Organization Part Number Package Power
Speed Grade
Clock Frequency
CL-tRCD-tRP
Notes
8M x 16
NT5SV8M16FS-6K
400mil 54-PIN
TSOP II
Lead-Free
3.3V
166MHz-3-3-3
Lead free packaging
NT5SV8M16FS-6KI Lead free packaging
NT5SV8M16FS-75B
133MHz-3-3-3
Lead free packaging
NT5SV8M16FS-75BI Lead free packaging
NT5SV8M16FT-6K
400mil 54-PIN
TSOP II
166MHz-3-3-3
NT5SV8M16FT-6KI
NT5SV8M16FT-75B
133MHz-3-3-3
NT5SV8M16FT-75BI
CL = CAS Latency
Lead-free products are also halogen-free
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
3
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Pin Configuration - 54 pins 400 mill TSOPII Package
<Top View >
54-pin Plastic TSOP(II) 400 mil
1
2
3
4
5
6
9
10
11
12
13
14
7
8
15
16
17
18
19
20
21
22
54
53
52
51
50
49
46
45
44
43
42
41
48
47
40
39
38
37
36
35
34
33
VDD
DQ0
VDDQ
DQ1
DQ2
VSSQ
VDDQ
DQ5
DQ6
VSSQ
DQ7
VDD
DQ3
DQ4
LDQM
WE
CAS
RAS
CS
BA0
BA1
VSS
DQ15
VSSQ
DQ14
DQ13
VDDQ
VSSQ
DQ10
DQ9
VDDQ
DQ8
VSS
DQ12
DQ11
NC
UDQM
CK
CKE
NC
A11
A9
23
24
25
32
31
30
A10/AP
A0
A1
A2
A8
A7
A6
A5
26
27
29
28
A3
VDD
A4
VSS
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
4
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Pin Description
CK Clock Input DQ0-DQ15 Data Input/Output
CKE (CKE0, CKE1) Clock Enable DQM, LDQM, UDQM Data Mask
CS Chip Select VDD Power (+3.3V)
RAS Row Address Strobe VSS Ground
CAS Column Address Strobe VDDQ Power for DQs (+3.3V)
WE Write Enable VSSQ Ground for DQs
BA1, BA0 Bank Select NC No Connection
A0 - A11 Address Inputs
Input/Output Functional Description
Symbol Type Polarity Function
CK Input Positive
Edge The system clock input. All of the SDRAM inputs are sampled on the rising edge of the clock.
CKE, CKE0,
CKE1 Input Active High Activates the CK signal when high and deactivates the CK signal when low. By deactivating the
clock, CKE low initiates the Power Down mode, Suspend mode, or the Self Refresh mode.
CS Input Active Low CS enables the command decoder when low and disables the command decoder when high. When
the command decoder is disabled, new commands are ignored but previous operations continue.
RAS, CAS, WE Input Active Low When sampled at the positive rising edge of the clock, CAS, RAS, and WE define the operation to be
executed by the SDRAM.
BA1, BA0 Input Selects which bank is to be active.
A0 - A11 Input
During a Bank Activate command cycle, A0-A11 defines the row address (RA0-RA11) when sam-
pled at the rising clock edge.
During a Read or Write command cycle, A0-A8 defines the column address (CA0-CA8), when sam-
pled at the rising clock edge.
A10 is used to invoke auto-precharge operation at the end of the burst read or write cycle. If A10 is
high, auto-precharge is selected and BA0, BA1 defines the bank to be precharged. If A10 is low,
autoprecharge is disabled.
During a Precharge command cycle, A10 is used in conjunction with BA0, BA1 to control which
bank(s) to precharge. If A10 is high, all banks will be precharged regardless of the state of BS. If A10
is low, then BA0 and BA1 are used to define which bank to precharge.
DQ0 - DQ15 Input-
Output Data Input/Output pins operate in the same manner as on conventional DRAMs.
DQM
LDQM
UDQM
Input Active High
The Data Input/Output mask places the DQ buffers in a high impedance state when sampled high. In
x16 products, the LDQM and UDQM control the lower and upper byte I/O buffers, respectively. In
Read mode, DQM has a latency of two clock cycles and controls the output buffers like an output
enable. DQM low turns the output buffers on and DQM high turns them off. In Write mode, DQM has
a latency of zero and operates as a word mask by allowing input data to be written if it is low but
blocks the write operation if DQM is high.
VDD, VSS Supply Power and ground for the input buffers and the core logic.
VDDQ VSSQ Supply Isolated power supply and ground for the output buffers to provide improved noise immunity.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
5
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Block Diagram
DQ0
DQX
Data Input/Output Buffers
CKE Buffer
CK Buffer
CKE
CK
CS
RAS
CAS
DQM
WE
Command Decoder
Mode Register
Counter
Column
Address
Counter
Refresh
A1
A2
A3
A4
A5
A6
A7
A10
A8
A9
A0
A11
Sense Amplifiers
Memory Bank 1
Cell Array
Row Decoder
Address Buffers (15)
Column Decoder
Sense Amplifiers
Memory Bank 3
Cell Array
Row Decoder
Column Decoder
Sense Amplifiers
Memory Bank 0
Cell Array
Row Decoder
Column Decoder
Sense Amplifiers
Memory Bank 2
Cell Array
Row Decoder
Column Decoder
Data Control Circuitry
BA0
BA1
Control Signal
Generator
Cell Array, per bank, for 4Mb x 16 DQ: 4096 Row x 512 Col x 16 DQ (DQ0-DQ15).
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
6
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Power On and Initialization
The default power on state of the mode register is supplier specific and may be undefined. The following power on and initializa-
tion sequence guarantees the device is preconditioned to each users specific needs.
Like a conventional DRAM, the Synchronous DRAM must be powered up and initialized in a predefined manner. During power
on, all VDD and VDDQ pins must be built up simultaneously to the specified voltage when the input signals are held in the “NOP”
state. The power on voltage must not exceed VDD+0.3V on any of the input pins or VDD supplies. The CK signal must be started
at the same time. After power on, an initial pause of 200µs is required followed by a precharge of all banks using the precharge
command. To prevent data contention on the DQ bus during power on, it is required that the DQM and CKE pins be held high
during the initial pause period. Once all banks have been precharged, the Mode Register Set Command must be issued to ini-
tialize the Mode Register. A minimum of two Auto Refresh cycles (CBR) are also required. These may be done before or after
programming the Mode Register. Failure to follow these steps may lead to unpredictable start-up modes.
Programming the Mode Register
For application flexibility, CAS latency, burst length, burst sequence, and operation type are user defined variables and must be
programmed into the SDRAM Mode Register with a single Mode Register Set Command. Any content of the Mode Register can
be altered by re-executing the Mode Register Set Command. If the user chooses to modify only a subset of the Mode Register
variables, all four variables must be redefined when the Mode Register Set Command is issued.
After initial power up, the Mode Register Set Command must be issued before read or write cycles may begin. All banks must
be in a precharged state and CKE must be high at least one cycle before the Mode Register Set Command can be issued. The
Mode Register Set Command is activated by the low signals of RAS, CAS, CS, and WE at the positive edge of the clock. The
address input data during this cycle defines the parameters to be set as shown in the Mode Register Operation table. A new
command may be issued following the mode register set command once a delay equal to tRSC has elapsed.
CAS Latency
The CAS latency is a parameter that is used to define the delay from when a Read Command is registered on a rising clock
edge to when the data from that Read Command becomes available at the outputs. The CAS latency is expressed in terms of
clock cycles and can have a value of 2 or 3 cycles. The value of the CAS latency is determined by the speed grade of the
device and the clock frequency that is used in the application. A table showing the relationship between the CAS latency, speed
grade, and clock frequency appears in the Electrical Characteristics section of this document. Once the appropriate CAS
latency has been selected it must be programmed into the mode register after power up, for an explanation of this procedure
see Programming the Mode Register in the previous section.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
7
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Mode Register Operation (Address Input For Mode Set)
A11 A3A4 A2 A1 A0A10 A9 A8 A7 A6 A5 Address
BT Burst LengthCAS Latency Mode
CAS Latency
M6 M5 M4 Latency
0 0 0 Reserved
0 0 1 Reserved
0 1 0 2
0 1 1 3
1 0 0 Reserved
1 0 1 Reserved
1 1 0 Reserved
1 1 1 Reserved
Burst Length
M2 M1 M0
Length
Sequential Interleave
0 0 0 1 1
0 0 1 2 2
0 1 0 4 4
0 1 1 8 8
1 0 0 Reserved Reserved
1 0 1 Reserved Reserved
1 1 0 Reserved Reserved
1 1 1 Full Page Reserved
Burst Type
M3 Type
0 Sequential
1 Interleave
Operation Mode
M14 M13 M12 M11 M10 M9 M8 M7 Mode
0 0 0 0 0 0 0 0 Normal
0 0 0 0 0 1 0 0
Multiple Burst
with
Single Write
Operation Mode
BA1 Bus (Ax)
Register(Mx)
BA0
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
8
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst Mode Operation
Burst mode operation is used to provide a constant flow of data to memory locations (write cycle), or from memory locations
(read cycle). There are three parameters that define how the burst mode will operate. These parameters include burst
sequence, burst length, and operation mode. The burst sequence and burst length are programmable, and are determined by
address bits A0 - A3 during the Mode Register Set command. Operation mode is also programmable and is set by address bits
A7 - A11, BA0, and BA1.
The burst type is used to define the order in which the burst data will be delivered or stored to the SDRAM. Two types of burst
sequences are supported, sequential and interleaved. See the table below.
The burst length controls the number of bits that will be output after a Read Command, or the number of bits to be input after a
Write Command. The burst length can be programmed to have values of 1, 2, 4, 8 and full page sequential burst.
Burst operation mode can be normal operation or multiple burst with single write operation. Normal operation implies that the
device will perform burst operations on both read and write cycles until the desired burst length is satisfied. Multiple burst with
single write operation was added to support Write Through Cache operation. Here, the programmed burst length only applies to
read cycles. All write cycles are single write operations when this mode is selected.
Note: Page length is a function of I/O organization and column addressing.
x16 organization (CA0-CA8); Page Length = 512 bits
Burst Length and Sequence
Burst Length Starting Address (A2 A1 A0) Sequential Addressing (decimal) Interleave Addressing (decimal)
2x x 0 0, 1 0, 1
x x 1 1, 0 1, 0
4
x 0 0 0, 1, 2, 3 0, 1, 2, 3
x 0 1 1, 2, 3, 0 1, 0, 3, 2
x 1 0 2, 3, 0, 1 2, 3, 0, 1
x 1 1 3, 0, 1, 2 3, 2, 1, 0
8
0 0 0 0, 1, 2, 3, 4, 5, 6, 7 0, 1, 2, 3, 4, 5, 6, 7
0 0 1 1, 2, 3, 4, 5, 6, 7, 0 1, 0, 3, 2, 5, 4, 7, 6
0 1 0 2, 3, 4, 5, 6, 7, 0, 1 2, 3, 0, 1, 6, 7, 4, 5
0 1 1 3, 4, 5, 6, 7, 0, 1, 2 3, 2, 1, 0, 7, 6, 5, 4
1 0 0 4, 5, 6, 7, 0, 1, 2, 3 4, 5, 6, 7, 0, 1, 2, 3
1 0 1 5, 6, 7, 0, 1, 2, 3, 4 5, 4, 7, 6, 1, 0, 3, 2
1 1 0 6, 7, 0, 1, 2, 3, 4, 5 6, 7, 4, 5, 2, 3, 0, 1
1 1 1 7, 0, 1, 2, 3, 4, 5, 6 7, 6, 5, 4, 3, 2, 1, 0
256
(Full Page) n= A0-A7 Cn, Cn1+2, Cn+3, C+4, ... Not supported
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
9
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Bank Activate Command
In relation to the operation of a fast page mode DRAM, the Bank Activate command correlates to a falling RAS signal. The Bank
Activate command is issued by holding CAS and WE high with CS and RAS low at the rising edge of the clock. The Bank Select
address BA0 - BA1 is used to select the desired bank. The row address A0 - A11 is used to determine which row to activate in
the selected bank.
The Bank Activate command must be applied before any Read or Write operation can be executed. The delay from when the
Bank Activate command is applied to when the first read or write operation can begin must meet or exceed the RAS to CAS
delay time (tRCD). Once a bank has been activated it must be precharged before another Bank Activate command can be
applied to the same bank. The minimum time interval between successive Bank Activate commands to the same bank is deter-
mined by the RAS cycle time of the device (tRC). The minimum time interval between interleaved Bank Activate commands
(Bank A to Bank B and vice versa) is the Bank to Bank delay time (tRRD). The maximum time that each bank can be held active
is specified as tRAS(max).
Bank Select
The Bank Select inputs, BA0 and BA1, determine the bank to be used during a Bank Activate, Precharge, Read, or Write oper-
ation.
Bank Activate Command Cycle
Bank Selection Bits
BA0 BA1 Bank
0 0 Bank 0
1 0 Bank 1
0 1 Bank 2
1 1 Bank 3
ADDRESS
CK
T0 T2T1 T3 Tn Tn+1 Tn+2 Tn+3
COMMAND NOP NOP NOP NOP
Bank A
Row Addr.
Bank A
Activate
Write A
with Auto
Bank A
Col. Addr.
. . . . . . . . . .
. . . . . . . . . .
. . . . . . . . . . Bank B
Activate
Bank A
Row Addr.
Bank A
Activate
RAS-CAS delay (tRCD)
: “H” or “L”
RAS Cycle time (tRC)
Precharge
RAS - RAS delay time (tRRD)
Bank B
Row Addr.
(CAS Latency = 3, tRCD = 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
10
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Read and Write Access Modes
After a bank has been activated, a read or write cycle can be executed. This is accomplished by setting RAS high and CAS low
at the clock’s rising edge after the necessary RAS to CAS delay (tRCD). WE must also be defined at this time to determine
whether the access cycle is a read operation (WE high), or a write operation (WE low). The address inputs determine the start-
ing column address.
The SDRAM provides a wide variety of fast access modes. A single Read or Write Command will initiate a serial read or write
operation on successive clock cycles up to 133 MHz for PC133 or upto 166MHz for PC166 devices. The number of serial data
bits for each access is equal to the burst length, which is programmed into the Mode Register.
Similar to Page Mode of conventional DRAMs, a read or write cycle can not begin until the sense amplifiers latch the selected
row address information. The refresh period (tREF) is what limits the number of random column accesses to an activated bank.
A new burst access can be done even before the previous burst ends. The ability to interrupt a burst operation at every clock
cycle is supported; this is referred to as the 1-N rule. When the previous burst is interrupted by another Read or Write Com-
mand, the remaining addresses are overridden by the new address.
Precharging an active bank after each read or write operation is not necessary providing the same row is to be accessed again.
To perform a read or write cycle to a different row within an activated bank, the bank must be precharged and a new Bank Acti-
vate command must be issued. When more than one bank is activated, interleaved (ping pong) bank Read or Write operations
are possible. By using the programmed burst length and alternating the access and precharge operations between multiple
banks, fast and seamless data access operation among many different pages can be realized. When multiple banks are acti-
vated, column to column interleave operation can be done between different pages. Finally, Read or Write Commands can be
issued to the same bank or between active banks on every clock cycle.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
11
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst Read Command
The Burst Read command is initiated by having CS and CAS low while holding RAS and WE high at the rising edge of the clock.
The address inputs determine the starting column address for the burst, the Mode Register sets the type of burst (sequential or
interleave) and the burst length (1, 2, 4, 8). The delay from the start of the command to when the data from the first cell appears
on the outputs is equal to the value of the CAS latency that is set in the Mode Register.
Read Interrupted by a Read
A Burst Read may be interrupted before completion of the burst by another Read Command, with the only restriction being that
the interval that separates the commands must be at least one clock cycle. When the previous burst is interrupted, the remain-
ing addresses are overridden by the new address with the burst length. The data from the first Read Command continues to
appear on the outputs until the CAS latency from the interrupting Read Command is satisfied, at this point the data from the
interrupting Read Command appears.
Burst Read Operation
Read Interrupted by a Read
COMMAND READ A NOP NOP NOP NOP NOP NOP NOP
DOUT A0
CAS latency = 2
tCK3, DQs
CAS latency = 3
DOUT A1DOUT A2DOUT A3
NOP
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
tCK2, DQs
DOUT A0DOUT A1DOUT A2DOUT A3
(Burst Length = 4, CAS latency = 2, 3)
COMMAND READ A READ B NOP NOP NOP NOP NOP NOP
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
NOP
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
DOUT B0DOUT B1DOUT B2DOUT B3
DOUT A0
DOUT B0DOUT B1DOUT B2DOUT B3
DOUT A0
(Burst Length = 4, CAS latency = 2, 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
12
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Read Interrupted by a Write
To interrupt a burst read with a Write Command, DQM may be needed to place the DQs (output drivers) in a high impedance
state to avoid data contention on the DQ bus. If a Read Command will issue data on the first or second clocks cycles of the
write operation, DQM is needed to insure the DQs are tri-stated. After that point the Write Command will have control of the DQ
bus.
Minimum Read to Write Interval
COMMAND NOPNOP READ A WRITE A NOP NOP NOP
DQM
DIN A0DIN A1DIN A2DIN A3
: “H” or “L”
DIN A0DIN A1DIN A2DIN A3
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
CK T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOP
(Burst Length = 4, CAS latency = 2, 3)
DQM high for CAS latency = 2 only.
Required to mask first bit of READ data.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
13
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Non-Minimum Read to Write Interval
COMMAND NOPNOPREAD A WRITE A NOP NOP NOP
DQM
DIN A0DIN A1DIN A2DIN A3
DIN A0DIN A1DIN A2DIN A3
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOP
CL = 3: DQM needed to
mask first bit of READ data.
CL = 2: DQM needed to mask
first, second bit of READ data.
(Burst Length = 4, CAS latency = 2, 3)
: DQM high for CAS latency = 2
: DQM high for CAS latency = 3
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
14
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst Write Command
The Burst Write command is initiated by having CS, CAS, and WE low while holding RAS high at the rising edge of the clock.
The address inputs determine the starting column address. There is no CAS latency required for burst write cycles. Data for the
first burst write cycle must be applied on the DQ pins on the same clock cycle that the Write Command is issued. The remaining
data inputs must be supplied on each subsequent rising clock edge until the burst length is completed. When the burst has fin-
ished, any additional data supplied to the DQ pins will be ignored.
Write Interrupted by a Write
A burst write may be interrupted before completion of the burst by another Write Command. When the previous burst is inter-
rupted, the remaining addresses are overridden by the new address and data will be written into the device until the pro-
grammed burst length is satisfied.
Burst Write Operation
Write Interrupted by a Write
COMMAND NOP WRITE A WRITE B NOP NOP NOP NOP NOP
DQs DIN A0DIN B0DIN B1DIN B2
NOP
DIN B3
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
1 CK Interval
(Burst Length = 4, CAS latency = 2, 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
15
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Write Interrupted by a Read
A Read Command will interrupt a burst write operation on the same clock cycle that the Read Command is registered. The DQs
must be in the high impedance state at least one cycle before the interrupting read data appears on the outputs to avoid data
contention. When the Read Command is registered, any residual data from the burst write cycle will be ignored. Data that is pre-
sented on the DQ pins before the Read Command is initiated will actually be written to the memory.
Minimum Write to Read Interval
COMMAND NOPWRITE A READ B NOP NOP NOP NOP NOP NOP
tCK2, DQs
CAS latency = 2 DIN A0
tCK3, DQs
CAS latency = 3 DIN A0
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
Input data for the Write is masked. Input data must be removed from the DQs at least one clock
cycle before the Read data appears on the outputs to avoid
data contention.
DOUT B0DOUT B1DOUT B2DOUT B3
DOUT B0DOUT B1DOUT B2DOUT B3
(Burst Length = 4, CAS latency = 2, 3)
: “H” or “L”
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
16
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Non-Minimum Write to Read Interval
COMMAND WRITE A READ B NOP NOP NOP NOP NOP NOP
tCK2, DQs
CAS latency = 2 DIN A0
tCK3, DQs
CAS latency = 3 DIN A0
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
Input data for the Write is masked. Input data must be removed from the DQs at least one clock
cycle before the Read data appears on the outputs to avoid
data contention.
DOUT B0DOUT B1DOUT B2DOUT B3
DOUT B0DOUT B1DOUT B2DOUT B3
NOP
DIN A1
DIN A1
(Burst Length = 4, CAS latency = 2, 3)
: “H” or “L”
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
17
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Auto-Precharge Operation
Before a new row in an active bank can be opened, the active bank must be precharged using either the Precharge Command
or the auto-precharge function. When a Read or a Write Command is given to the SDRAM, the CAS timing accepts one extra
address, column address A10, to allow the active bank to automatically begin precharge at the earliest possible moment during
the burst read or write cycle. If A10 is low when the Read or Write Command is issued, then normal Read or Write burst opera-
tion is executed and the bank remains active at the completion of the burst sequence. If A10 is high when the Read or Write
Command is issued, then the auto-precharge function is engaged. During auto-precharge, a Read Command will execute as
normal with the exception that the active bank will begin to precharge before all burst read cycles have been completed.
Regardless of burst length, the precharge will begin (CAS latency - 1) clocks prior to the last data output. Auto-precharge can
also be implemented during Write commands.
A Read or Write Command without auto-precharge can be terminated in the midst of a burst operation. However, a Read or
Write Command with auto-precharge cannot be interrupted by a command to the same bank. Therefore use of a Read, Write, or
Precharge Command to the same bank is prohibited during a read or write cycle with auto-precharge until the entire burst oper-
ation is completed. Once the precharge operation has started the bank cannot be reactivated until the Precharge time (tRP) has
been satisfied.
When using the Auto-precharge Command, the interval between the Bank Activate Command and the beginning of the internal
precharge operation must satisfy tRAS(min). If this interval does not satisfy tRAS(min) then tRCD must be extended.
Burst Read with Auto-Precharge
COMMAND NOP NOP NOP NOP
READ A
Auto-Precharge
tRP
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOPNOP
tRP
*
*
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
Begin Auto-precharge *Bank can be reactivated at completion of tRP.
DOUT A0
DOUT A0
NOP
tRP is a function of clock cycle time and speed sort.
See the Clock Frequency and Latency table.
(Burst Length = 1, CAS Latency = 2, 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
18
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst Read with Auto-Precharge
Burst Read with Auto-Precharge
COMMAND NOP NOP NOP NOP
READ A
Auto-Precharge
tRP
CK T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOPNOP
tRP
*
*
*
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
Begin Auto-precharge
DOUT A0
DOUT A0
NOP
DOUT A1
DOUT A1
*Bank can be reactivated at completion of tRP.
tRP is a function of clock cycle time and speed sort.
See the Clock Frequency and Latency table.
(Burst Length = 2, CAS Latency = 2, 3)
COMMAND NOP NOP NOP NOP
READ A
Auto-Precharge
tRP
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOPNOP
tRP
*
*
*
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
Begin Auto-precharge
DOUT A0DOUT A1DOUT A2DOUT A3
NOP
DOUT A0DOUT A1DOUT A2DOUT A3
*Bank can be reactivated at completion of tRP.
tRP is a function of clock cycle time and speed sort.
See the Clock Frequency and Latency table.
(Burst Length = 4, CAS Latency = 2, 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
19
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Although a Read Command with auto-precharge can not be interrupted by a command to the same bank, it can be interrupted
by a Read or Write Command to a different bank. If the command is issued before auto-precharge begins then the precharge
function will begin with the new command. The bank being auto-precharged may be reactivated after the delay tRP.
If interrupting a Read Command with auto-precharge with a Write Command, DQM must be used to avoid DQ contention.
Burst Read with Auto-Precharge Interrupted by Read
Burst Read with Auto-Precharge Interrupted by Write
tRP
COMMAND NOP NOP NOP NOP
READ A
Auto-Precharge
CK T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOP
tRP
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
*Bank can be reactivated at completion of tRP.
DOUT A0DOUT A1
NOP
DOUT A0DOUT A1DOUT B0DOUT B1
READ B
DOUT B2DOUT B3
DOUT B0DOUT B1DOUT B2DOUT B3
tRP is a function of clock cycle time and speed sort.
See the Clock Frequency and Latency table.
*
*
(Burst Length = 4, CAS Latency = 2, 3)
COMMAND NOP NOP NOP
READ A
Auto-Precharge
tRP
CK T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOP
tCK2, DQs
CAS latency = 2
DQM
NOP
DOUT A0DIN B0DIN B1
WRITE B
DIN B2DIN B3
NOP
DIN B4
*Bank can be reactivated at completion of tRP.
tRP is a function of clock cycle time and speed sort..
See the Clock Frequency and Latency table.
*
(Burst Length = 8, CAS Latency = 2)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
20
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
If A10 is high when a Write Command is issued, the Write with Auto-Precharge function is initiated. The bank undergoing auto-
precharge cannot be reactivated until tDAL, Data-in to Active delay, is satisfied.
Similar to the Read Command, a Write Command with auto-precharge can not be interrupted by a command to the same bank.
It can be interrupted by a Read or Write Command to a different bank, however. The interrupting command will terminate the
write. The bank undergoing auto-precharge can not be reactivated until tDAL is satisfied.
Burst Write with Auto-Precharge
Burst Write with Auto-Precharge Interrupted by Write
DIN A0
COMMAND NOP NOP NOP NOP
WRITE A
Auto-Precharge
DIN A1
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
NOP
DIN A0DIN A1
tCK2, DQs
CAS latency = 2
tCK3, DQs
CAS latency = 3
NOP NOP
NOP
*Bank can be reactivated at completion of tDAL.
tDAL
tDAL*
*
(Burst Length = 2, CAS Latency = 2, 3)
See the Clock Frequency and Latency table.
tDAL is a function of clock cycle time and speed sort.
DIN A0
COMMAND NOP NOP NOP
WRITE A
Auto-Precharge
DIN A1
tDAL
CK
T0 T1 T2 T3 T4 T5
NOP
tCK3, DQs
CAS latency = 3
WRITE B
DIN B0DIN B1DIN B2DIN B3
T6 T7 T8
NOP NOPNOP
*Bank can be reactivated at completion of tDAL.
*
(Burst Length = 4, CAS Latency = 3)
See the Clock Frequency and Latency table.
tDAL is a function of clock cycle time and speed sort.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
21
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Precharge Command
The Precharge Command is used to precharge or close a bank that has been activated. The Precharge Command is triggered
when CS, RAS, and WE are low and CAS is high at the rising edge of the clock. The Precharge Command can be used to pre-
charge each bank separately or all banks simultaneously. Three address bits, A10, BA0, and BA1, are used to define which
bank(s) is to be precharged when the command is issued.
For read cycles, the Precharge Command may be applied (CAS latency - 1) prior to the last data output. For write cycles, a
delay must be satisfied from the start of the last burst write cycle until the Precharge Command can be issued. This delay is
known as tDPL, Data-in to Precharge delay.
After the Precharge Command is issued, the precharged bank must be reactivated before a new read or write access can be
executed. The delay between the Precharge Command and the Activate Command must be greater than or equal to the Pre-
charge time (tRP).
Burst Write with Auto-Precharge Interrupted by Read
Bank Selection for Precharge by Address Bits
A10 Bank Select Precharged Bank(s)
LOW BA0, BA1 Single bank defined by BA0, BA1
HIGH DON’T CARE All Banks
DIN A0
COMMAND NOP NOP NOP
WRITE A
Auto-Precharge
DIN A1
CK T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOP
NOP
*
tCK3, DQs
CAS latency = 3
Bank A can be reactivated at completion of tDAL.
*
READ B
DIN A2
NOP
DOUT B0DOUT B1DOUT B2
tDAL
(Burst Length = 4, CAS Latency = 3)
See the Clock Frequency and Latency table.
tDAL is a function of clock cycle time and speed sort.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
22
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst Read Followed by the Precharge Command
Burst Write Followed by the Precharge Command
COMMAND READ Ax0NOP NOP NOP NOP NOP NOP NOP
tCK2, DQs
CAS latency = 3
CK T0 T2T1 T3 T4 T5 T6 T7 T8
DOUT Ax0DOUT Ax1DOUT Ax2DOUT Ax3
Precharge A
tRP
Bank A can be reactivated at completion of tRP.
*
*
(Burst Length = 4, CAS Latency = 3)
tRP is a function of clock cycle and speed sort.
COMMAND NOP NOP NOP
WRITE Ax0
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOPNOP
DIN Ax0DIN Ax1
Bank can be reactivated at completion of tRP.
*
Activate
Bank Ax
tCK2, DQs
CAS latency = 2
tDPL*
tRP
Precharge A
‡ tDPL and tRP are functions of clock cycle and speed sort.
See the Clock Frequency and Latency table.
(Burst Length = 2, CAS Latency = 2)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
23
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Precharge Termination
The Precharge Command may be used to terminate either a burst read or burst write operation. When the Precharge command
is issued, the burst operation is terminated and bank precharge begins. For burst read operations, valid data will continue to
appear on the data bus as a function of CAS Latency.
Burst Read Interrupted by Precharge
COMMAND READ Ax0NOP NOP NOP NOP NOP NOP NOP
tCK2, DQs
CAS latency = 2
CK T0 T2T1 T3 T4 T5 T6 T7 T8
DOUT Ax0DOUT Ax1DOUT Ax2DOUT Ax3
Precharge A
tCK3, DQs
CAS latency = 3 DOUT Ax0DOUT Ax1DOUT Ax2DOUT Ax3
tRP
tRP
*
*
Bank A can be reactivated at completion of tRP.
*See the Clock Frequency and Latency table.
(Burst Length = 8, CAS Latency = 2, 3)
tRP is a function of clock cycle time and speed sort.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
24
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst write operations will be terminated by the Precharge command. The last write data that will be properly stored in the
device is that write data that is presented to the device a number of clock cycles prior to the Precharge command equal to the
Data-in to Precharge delay, tDPL.
Precharge Termination of a Burst Write
COMMAND NOP NOP NOP
WRITE Ax0
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
NOP NOP
NOP
DIN Ax1DIN Ax2
tDPL
DIN Ax0
tCK2, DQs
CAS latency = 2
NOP
DIN Ax1DIN Ax2
DIN Ax0
tCK3, DQs
CAS latency = 3
DQM
Precharge A
tDPL is an asynchronous timing and may be completed in one or two clock cycles
depending on clock cycle time.
(Burst Length = 8, CAS Latency = 2, 3)
tDPL
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
25
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Automatic Refresh Command (CAS before RAS Refresh)
When CS, RAS, and CAS are held low with CKE and WE high at the rising edge of the clock, the chip enters the Automatic
Refresh mode (CBR). All banks of the SDRAM must be precharged and idle for a minimum of the Precharge time (tRP) before
the Auto Refresh Command (CBR) can be applied. An address counter, internal to the device provides the address during the
refresh cycle. No control of the external address pins is required once this cycle has started.
When the refresh cycle has completed, all banks of the SDRAM will be in the precharged (idle) state. A delay between the Auto
Refresh Command (CBR) and the next Activate Command or subsequent Auto Refresh Command must be greater than or
equal to the RAS cycle time (tRC).
Self Refresh Command
The SDRAM device has a built-in timer to accommodate Self Refresh operation. The Self Refresh Command is defined by hav-
ing CS, RAS, CAS, and CKE held low with WE high at the rising edge of the clock. All banks must be idle prior to issuing the
Self Refresh Command. Once the command is registered, CKE must be held low to keep the device in Self Refresh mode.
When the SDRAM has entered Self Refresh mode all of the external control signals, except CKE, are disabled. The clock is
internally disabled during Self Refresh Operation to save power. The user may halt the external clock while the device is in Self
Refresh mode, however, the clock must be restarted before the device can exit Self Refresh operation. Once the clock is
cycling, the device will exit Self Refresh operation after CKE is returned high. A minimum delay time is required when the device
exits Self Refresh Operation and before the next command can be issued. This delay is equal to the RAS cycle time (tRC) plus
the Self Refresh exit time (tSREX).
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
26
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Power Down Mode
In order to reduce standby power consumption, two power down modes are available: Precharge and Active Power Down
mode. To enter Precharge Power Down mode, all banks must be precharged and the necessary precharge delay (tRP) must
occur before the SDRAM can enter the power down mode. If a bank is activated but not performing a Read or Write operation,
Active Power Down mode will be entered. (Issuing a Power Down Mode Command when the device is performing a Read or
Write operation causes the device to enter Clock Suspend mode. See the following Clock Suspend section.) Once the Power
Down mode is initiated by holding CKE low, all of the receiver circuits except CKE are gated off. The Power Down mode does
not perform any refresh operations, therefore the device can’t remain in Power Down mode longer than the Refresh period
(tREF) of the device.
The Power Down mode is exited by bringing CKE high. When CKE goes high, a No Operation Command (or Device Deselect
Command) is required on the next rising clock edge.
Power Down Mode Exit Timing
COMMAND NOP COMMAND NOP NOP NOP NOP NOP
CKE
: “H” or “L”
CK
Tm Tm+2Tm+1 Tm+3 Tm+4 Tm+5 Tm+6 Tm+7 Tm+ 8
tCES(min)
tCK
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
27
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Data Mask
The SDRAM has a Data Mask function that can be used in conjunction with data read and write cycles. When the Data Mask is
activated (DQM high) during a write cycle, the write operation is prohibited immediately (zero clock latency). If the Data Mask is
activated during a read cycle, the data outputs are disabled and become high impedance after a two-clock delay, independent
of CAS latency.
No Operation Command
The No Operation Command should be used in cases when the SDRAM is in an idle or a wait state. The purpose of the No
Operation Command is to prevent the SDRAM from registering any unwanted commands between operations. A No Operation
Command is registered when CS is low with RAS, CAS, and WE held high at the rising edge of the clock. A No Operation Com-
mand will not terminate a previous operation that is still executing, such as a burst read or write cycle.
Deselect Command
The Deselect Command performs the same function as a No Operation Command. Deselect Command occurs when CS is
brought high, the RAS, CAS, and WE signals become don’t cares.
Data Mask Activated during a Read Cycle
COMMAND NOP READ A NOP NOP NOP NOP NOP NOP NOP
DQM
: “H” or “L”
A two-clock delay before
the DQs become Hi-Z
DQs
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
DOUT A0DOUT A1
(Burst Length = 4, CAS Latency = 2)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
28
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Clock Suspend Mode
During normal access mode, CKE is held high, enabling the clock. When CKE is registered low while at least one of the banks
is active, Clock Suspend Mode is entered. The Clock Suspend mode deactivates the internal clock and suspends or “freezes”
any clocked operation that was currently being executed. There is a one-clock delay between the registration of CKE low and
the time at which the SDRAM’s operation suspends. While in Clock Suspend mode, the SDRAM ignores any new commands
that are issued. The Clock Suspend mode is exited by bringing CKE high. There is a one clock cycle delay from when CKE
returns high to when Clock Suspend mode is exited.
When the operation of the SDRAM is suspended during the execution of a Burst Read operation, the last valid data output onto
the DQ pins will be actively held valid until Clock Suspend mode is exited.
If Clock Suspend mode is initiated during a burst write operation, the input data is masked and is ignored until the Clock Sus-
pend mode is exited.
Clock Suspend during a Read Cycle
Clock Suspend during a Write Cycle
CK
T0 T2T1 T3 T4 T5 T6 T7 T8
COMMAND NOP READ A NOP NOP NOP NOP
CKE
DQs DOUT A0DOUT A2
DOUT A1
: “H” or “L”
A one clock delay before
suspend operation starts
A one clock delay to exit
the Suspend command
DOUT element at the DQs when the
suspend operation starts is held valid
(Burst Length = 4, CAS Latency = 2)
CK T0 T2T1 T3 T4 T5 T6 T7 T8
COMMAND NOP WRITE A NOP NOP NOP NOP
CKE
DQs DIN A2DIN A3
: “H” or “L”
A one clock delay before
suspend operation starts
A one clock delay to exit
the Suspend command
DIN is masked during the Clock Suspend Period
DIN A1
DIN A0
(Burst Length = 4, CAS Latency = 2)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
29
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Command Truth Table (See note 1)
Function Device State
CKE
CS RAS CAS WE DQM BA0,
BA1 A10 A11,
A9-A0 Notes
Previous
Cycle
Current
Cycle
Mode Register Set Idle H X L L L L X OP Code
Auto (CBR) Refresh Idle H H L L L H X X X X
Entry Self Refresh Idle H L L L L H X X X X
Exit Self Refresh Idle (Self-
Refresh) L H H X X X X X X X
L H H H
Single Bank Precharge See Current
State Table H X L L H L X BS L X 2
Precharge all Banks See Current
State Table H X L L H L X X H X
Bank Activate Idle H X L L H H X BS Row Address 2
Write Active H X L H L L X BS L Column 2
Write with Auto-Precharge Active H X L H L L X BS H Column 2
Read Active H X L H L H X BS L Column 2
Read with Auto-Precharge Active H X L H L H X BS H Column 2
Reserved H X L H H L X X X X
No Operation Any H X L H H H X X X X
Device Deselect Any H X H X X X X X X X
Clock Suspend Mode Entry Active H L X X X X X X X X 4
Clock Suspend Mode Exit Active L H X X X X X X X X
Data Write/Output Enable Active H X X X X X L X X X 5
Data Mask/Output Disable Active H X X X X X H X X X
Power Down Mode Entry Idle/Active H L H X X X X X X X 6, 7
L H H H
Power Down Mode Exit Any (Power
Down) L H H X X X X X X X 6, 7
L H H H
1. All of the SDRAM operations are defined by states of CS, WE, RAS, CAS, and DQM at the positive rising edge of the clock. Refer to the
Current State Truth Table.
2. Bank Select (BA0, BA1): BA0, BA1 = 0,0 selects bank 0; BA0, BA1 = 1,0 selects bank 1; BA0, BA1 = 0,1 selects bank 2; BA0, BA1 = 1,1
selects bank 3.
3. Not applicable.
4. During normal access mode, CKE is held high and CK is enabled. When it is low, it freezes the internal clock and extends data Read and
Write operations. One clock delay is required for mode entry and exit.
5. The DQM has two functions for the data DQ Read and Write operations. During a Read cycle, when DQM goes high at a clock timing the
data outputs are disabled and become high impedance after a two-clock delay. DQM also provides a data mask function for Write cycles.
When it activates, the Write operation at the clock is prohibited (zero clock latency).
6. All banks must be precharged before entering the Power Down Mode. (If this command is issued during a burst operation, the device
state will be Clock Suspend Mode.) The Power Down Mode does not perform any refresh operations; therefore the device can’t remain in
this mode longer than the Refresh period (tREF) of the device. One clock delay is required for mode entry and exit.
7. A No Operation or Device Deselect Command is required on the next clock edge following CKE going high.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
30
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Clock Enable (CKE) Truth Table
Current State
CKE Command
Action Notes
Previous
Cycle
Current
Cycle CS RAS CAS WE BA0,
BA1 A11 - A0
Self Refresh
H X X X X X X X INVALID 1
L H H X X X X X Exit Self Refresh with Device Deselect 2
L H L H H H X X Exit Self Refresh with No Operation 2
L H L H H L X X ILLEGAL 2
L H L H L X X X ILLEGAL 2
L H L L X X X X ILLEGAL 2
L L X X X X X X Maintain Self Refresh
Power Down
H X X X X X X X INVALID 1
L H H X X X X X Power Down mode exit, all banks idle 2
L H L X X X X X ILLEGAL 2
L L X X X X X X Maintain Power Down Mode
All Banks Idle
H H H X X X
Refer to the Idle State section of the
Current State Truth Table
3
H H L H X X 3
H H L L H X 3
H H L L L H X X CBR Refresh
H H L L L L OP Code Mode Register Set 4
H L H X X X
Refer to the Idle State section of the
Current State Truth Table
3
H L L H X X 3
H L L L H X 3
H L L L L H X X Entry Self Refresh 4
H L L L L L OP Code Mode Register Set
L X X X X X X X Power Down 4
Any State
other than
listed above
H H X X X X X X Refer to operations in the Current State
Truth Table
H L X X X X X X Begin Clock Suspend next cycle 5
L H X X X X X X Exit Clock Suspend next cycle
L L X X X X X X Maintain Clock Suspend
1. For the given Current State CKE must be low in the previous cycle.
2. When CKE has a low to high transition, the clock and other inputs are re-enabled asynchronously. The minimum setup time for CKE
(tCES) must be satisfied. When exiting power down mode, a NOP command (or Device Deselect Command) is required on the first rising
clock after CKE goes high (see page 26).
3. The address inputs depend on the command that is issued. See the Idle State section of the Current State Truth Table for more informa-
tion.
4. The Precharge Power Down Mode, the Self Refresh Mode, and the Mode Register Set can only be entered from the all banks idle state.
5. Must be a legal command as defined in the Current State Truth Table.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
31
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Current State Truth Table (Part 1 of 3)(See note 1)
Current State Command Action Notes
CS RAS CAS WE BA0,BA1 A11 - A0 Description
Idle
L L L L OP Code Mode Register Set Set the Mode Register 2
L L L H X X Auto or Self Refresh Start Auto or Self Refresh 2, 3
L L H L BS X Precharge No Operation
L L H H BS Row Address Bank Activate Activate the specified bank and row
L H L L BS Column Write w/o Precharge ILLEGAL 4
L H L H BS Column Read w/o Precharge ILLEGAL 4
L H H H X X No Operation No Operation
H X X X X X Device Deselect No Operation or Power Down 5
Row Active
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge Precharge 6
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write Start Write; Determine if Auto Precharge 7, 8
L H L H BS Column Read Start Read; Determine if Auto Precharge 7, 8
L H H H X X No Operation No Operation
H X X X X X Device Deselect No Operation
Read
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge Terminate Burst; Start the Precharge
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write Terminate Burst; Start the Write cycle 8, 9
L H L H BS Column Read Terminate Burst; Start a new Read cycle 8, 9
L H H L X X Burst Stop Burst Stop
L H H H X X No Operation Continue the Burst
H X X X X X Device Deselect Continue the Burst
Write
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge Terminate Burst; Start the Precharge
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write Terminate Burst; Start a new Write cycle 8, 9
L H L H BS Column Read Terminate Burst; Start the Read cycle 8, 9
L H H L X X Burst Stop Burst Stop
L H H H X X No Operation Continue the Burst
H X X X X X Device Deselect Continue the Burst
1. CKE is assumed to be active (high) in the previous cycle for all entries. The Current State is the state of the bank that the Command is
being applied to.
2. All Banks must be idle; otherwise, it is an illegal action.
3. If CKE is active (high) the SDRAM will start the Auto (CBR) Refresh operation, if CKE is inactive (low) than the Self Refresh mode is
entered.
4. The Current State refers to only one of the banks. If BS selects this bank then the action is illegal. If BS selects the bank not being refer-
enced by the Current State then the action may be legal depending on the state of that bank.
5. If CKE is inactive (low) then the Power Down mode is entered; otherwise there is a No Operation.
6. The minimum and maximum Active time (tRAS) must be satisfied.
7. The RAS to CAS Delay (tRCD) must occur before the command is given.
8. Column address A10 is used to determine if the Auto Precharge function is activated.
9. The command must satisfy any bus contention, bus turn around, and/or write recovery requirements.
10. The command is illegal if the minimum bank to bank delay time (tRRD) is not satisfied.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
32
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Read with
Auto Pre-
charge
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL 4
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write ILLEGAL 4
L H L H BS Column Read ILLEGAL 4
L H H H X X No Operation Continue the Burst
H X X X X X Device Deselect Continue the Burst
Write with Auto
Precharge
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL 4
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write ILLEGAL 4
L H L H BS Column Read ILLEGAL 4
L H H H X X No Operation Continue the Burst
H X X X X X Device Deselect Continue the Burst
Precharging
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge No Operation; Bank(s) idle after tRP
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write ILLEGAL 4
L H L H BS Column Read ILLEGAL 4
L H H H X X No Operation No Operation; Bank(s) idle after tRP
H X X X X X Device Deselect No Operation; Bank(s) idle after tRP
Row
Activating
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL 4
L L H H BS Row Address Bank Activate ILLEGAL 4, 10
L H L L BS Column Write ILLEGAL 4
L H L H BS Column Read ILLEGAL 4
L H H H X X No Operation No Operation; Row Active after tRCD
H X X X X X Device Deselect No Operation; Row Active after tRCD
Current State Truth Table (Part 2 of 3)(See note 1)
Current State Command Action Notes
CS RAS CAS WE BA0,BA1 A11 - A0 Description
1. CKE is assumed to be active (high) in the previous cycle for all entries. The Current State is the state of the bank that the Command is
being applied to.
2. All Banks must be idle; otherwise, it is an illegal action.
3. If CKE is active (high) the SDRAM will start the Auto (CBR) Refresh operation, if CKE is inactive (low) than the Self Refresh mode is
entered.
4. The Current State refers to only one of the banks. If BS selects this bank then the action is illegal. If BS selects the bank not being refer-
enced by the Current State then the action may be legal depending on the state of that bank.
5. If CKE is inactive (low) then the Power Down mode is entered; otherwise there is a No Operation.
6. The minimum and maximum Active time (tRAS) must be satisfied.
7. The RAS to CAS Delay (tRCD) must occur before the command is given.
8. Column address A10 is used to determine if the Auto Precharge function is activated.
9. The command must satisfy any bus contention, bus turn around, and/or write recovery requirements.
10. The command is illegal if the minimum bank to bank delay time (tRRD) is not satisfied.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
33
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Write
Recovering
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL 4
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write Start Write; Determine if Auto Precharge 9
L H L H BS Column Read Start Read; Determine if Auto Precharge 9
L H H H X X No Operation No Operation; Row Active after tDPL
H X X X X X Device Deselect No Operation; Row Active after tDPL
Write
Recovering
with
Auto Pre-
charge
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL 4
L L H H BS Row Address Bank Activate ILLEGAL 4
L H L L BS Column Write ILLEGAL 4, 9
L H L H BS Column Read ILLEGAL 4, 9
L H H H X X No Operation No Operation; Precharge after tDPL
H X X X X X Device Deselect No Operation; Precharge after tDPL
Refreshing
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL
L L H H BS Row Address Bank Activate ILLEGAL
L H L L BS Column Write ILLEGAL
L H L H BS Column Read ILLEGAL
L H H H X X No Operation No Operation; Idle after tRC
H X X X X X Device Deselect No Operation; Idle after tRC
Mode
Register
Accessing
L L L L OP Code Mode Register Set ILLEGAL
L L L H X X Auto or Self Refresh ILLEGAL
L L H L BS X Precharge ILLEGAL
L L H H BS Row Address Bank Activate ILLEGAL
L H L L BS Column Write ILLEGAL
L H L H BS Column Read ILLEGAL
L H H H X X No Operation No Operation; Idle after two clock cycles
H X X X X X Device Deselect No Operation; Idle after two clock cycles
Current State Truth Table (Part 3 of 3)(See note 1)
Current State Command Action Notes
CS RAS CAS WE BA0,BA1 A11 - A0 Description
1. CKE is assumed to be active (high) in the previous cycle for all entries. The Current State is the state of the bank that the Command is
being applied to.
2. All Banks must be idle; otherwise, it is an illegal action.
3. If CKE is active (high) the SDRAM will start the Auto (CBR) Refresh operation, if CKE is inactive (low) than the Self Refresh mode is
entered.
4. The Current State refers to only one of the banks. If BS selects this bank then the action is illegal. If BS selects the bank not being refer-
enced by the Current State then the action may be legal depending on the state of that bank.
5. If CKE is inactive (low) then the Power Down mode is entered; otherwise there is a No Operation.
6. The minimum and maximum Active time (tRAS) must be satisfied.
7. The RAS to CAS Delay (tRCD) must occur before the command is given.
8. Column address A10 is used to determine if the Auto Precharge function is activated.
9. The command must satisfy any bus contention, bus turn around, and/or write recovery requirements.
10. The command is illegal if the minimum bank to bank delay time (tRRD) is not satisfied.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
34
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Absolute Maximum Ratings
Symbol Parameter Rating Units Notes
VDD Power Supply Voltage -1.0 to +4.6 V 1
VDDQ Power Supply Voltage for Output -1.0 to +4.6 V 1
VIN Input Voltage -0.3 to VDD+0.3 V 1
VOUT Output Voltage -0.3 to VDD+0.3 V 1
TAOperating Temperature (ambient)
Commerical 0 to +70 °C 1
Industrial -40 to +85 °C 1
TSTG Storage Temperature -55 to +150 °C 1
PDPower Dissipation 1.0 W 1
IOUT Short Circuit Output Current 50 mA 1
1. Stresses greater than those listed under “Absolute Maximum Ratings” may cause permanent damage to the device. This
is a stress rating only and functional operation of the device at these or any other conditions above those indicated in the
operational sections of this specification is not implied. Exposure to absolute maximum rating conditions for extended
periods may affect reliability.
Recommended DC Operating Conditions
Symbol Parameter
Rating
Units Notes
Min. Typ. Max.
VDD Supply Voltage 3.0 3.3 3.6 V 1
VDDQ Supply Voltage for Output 3.0 3.3 3.6 V 1
VIH Input High Voltage 2.0 3.0 VDD + 0.3 V 1, 2
VIL Input Low Voltage -0.3 0 0.8 V 1, 3
VOH Output Logic High Voltage 2.4 V IoH = -2mA
VOL Output Logic Low Voltage 0.4 V IoL = 2mA
1. All voltages referenced to VSS and VSSQ.
2. VIH (max) = VDD + 2.3V for pulse width 3ns.
3. VIL (min) = VSS - 2.0V for pulse width 3ns.
Capacitance (TA = 23°C, f = 1MHz, VDD = 3.3V, VREF=1.4+/-200mV )
Symbol Parameter Min. 64Mb
Max.
128Mb
Max. Units
CIN Input Capacitance (A0-A11, BS0, BS1, CS, RAS, CAS, WE, CKE, DQM) 2.5 5.0 3.8 pF
CADD Address 2.5 5.0 3.8 pF
CCLK Input Clock (CLK) 2.5 4.0 3.5 pF
COUT Output Capacitance (DQ0 - DQ15) 4.0 6.5 6.0 pF
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
35
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
DC Electrical Characteristics (VDD = 3.3V ±0.3V)
Symbol Parameter Min. Max. Units
II(L)
Input Leakage Current, any input
(0.0V VIN VDD), All Other Pins Not Under Test = 0V -1 +1 µA
IO(L)
Output Leakage Current
(DOUT is disabled, 0.0V VOUT VDDQ)-1 +1 µA
VOH
Output Level (LVTTL)
Output “H” Level Voltage (IOUT = -2.0mA) 2.4 V
VOL
Output Level (LVTTL)
Output “L” Level Voltage (IOUT = +2.0mA) 0.4 V
DC Output Load Circuit
Output
1200
50pF
3.3 V
870
VOH (DC) = 2.4V, IOH = -2mA
VOL (DC) = 0.4V, IOL = 2mA
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
36
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
dc
Operating, Standby, and Refresh Currents
Parameter Symbol Test Condition Max. Units Notes
6K 6KI 75B 75BI
Operating Current ICC1
1 bank operation
tRC = tRC(min), tCK = min
Active-Precharge command cycling without
burst operation
130 130 90 90 mA 1, 2, 3
Precharge Standby Current
in Power Down Mode
ICC2P
CKE VIL(max), tCK = min,
CS = VIH(min) 4 4 4 4 mA 1
ICC2PS
CKE VIL(max), tCK = Infinity,
CS = VIH(min) 4 4 4 4 mA 1
Precharge Standby Current
in Non-Power Down Mode
ICC2N
CKE VIH(min), tCK = min,
CS = VIH (min) 20 20 20 20 mA 1, 5
ICC2NS CKE VIH(min), tCK = Infinity, 10 10 10 10 mA 1, 7
No Operating Current
(Active state: 4 bank)
ICC3N
CKE VIH(min), tCK = min,
CS = VIH (min) 35 35 35 35 mA 1, 5
ICC3P CKE VIL(max), tCK = min, 5 7 5 7 mA 1, 6
Operating Current (Burst
Mode) ICC4
tCK = min, Read/ Write command cycling,
Multiple banks active, gapless data, BL = 4 150 150 110 110 mA 1, 3, 4
Auto (CBR) Refresh Current ICC5
tCK = min, tRC = tRC(min)
CBR command cycling 220 220 200 200 mA 1
Self Refresh Current ICC6 CKE 0.2V 4 4 4 4 mA 1
1. Currents given are valid for a single device. .
2. These parameters depend on the cycle rate and are measured with the cycle determined by the minimum value of tCK and tRC. Input
signals are changed up to three times during tRC(min).
3. The specified values are obtained with the output open.
4. Input signals are changed once during tCK(min).
5. Input signals are changed once during three clock cycles.
6. Active Standby Current will be higher if Clock Suspend is entered during a burst read cycle (add 1mA per DQ).
7. Input signals are stable.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
37
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
AC Characteristics (VDD = 3.3V ± 0.3V)
1. An initial pause of 200µs, with DQM and CKE held high, is required after power-up. A Precharge All Banks command must
be given followed by a minimum of two Auto (CBR) Refresh cycles before or after the Mode Register Set operation.
2. The Transition time is measured between VIH and VIL (or between VIL and VIH)
3. In addition to meeting the transition rate specification, the clock and CKE must transit between VIH and VIL (or between VIL
and VIH) in a monotonic manner.
4. Load Circuit A: AC timing tests have VIL = 0.4 V and VIH = 2.4 V with the timing referenced to the 1.40V crossover point
5. Load Circuit A: AC measurements assume tT = 1.0ns.
AC Characteristics Diagrams
Output
Input
Clock
tOH
tSETUP tHOLD
tAC
tLZ
1.4V
1.4V
1.4V
tT
Vtt = 1.4V
Output 50
50pF
Zo = 50
AC Output Load Circuit (A)
tCKH
tCKL
VIL
VIH
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
38
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Clock and Clock Enable Parameters
Symbol Parameter -6K/6KI -75B/75BI Units Notes
Min. Max. Min. Max.
tCK3 Clock Cycle Time, CAS Latency = 3 6 7.5 ns
tCK2 Clock Cycle Time, CAS Latency = 2 10 10 ns
tAC3 (A) Clock Access Time, CAS Latency = 3 5 5.4 ns 1
tAC2 (A) Clock Access Time, CAS Latency = 2 6 6 ns 1
tCKH Clock High Pulse Width 2.5 2.5 ns
tCKL Clock Low Pulse Width 2.5 2.5 ns
tCES Clock Enable Set-up Time 1.5 1.5 ns
tCEH Clock Enable Hold Time 1.0 0.8 ns
tSB Power down mode Entry Time 0 6 0 7.5 ns
tTTransition Time (Rise and Fall) 0.3 8 0.5 10 ns
1. Access time is measured at 1.4V. See AC Characteristics: notes 1, 2, 3, 4, 5 and load circuit A.
Common Parameters
Symbol Parameter
-6K/6KI -75B/75BI
Units Notes
Min. Max. Min. Max.
tCS Command Setup Time 1.5 1.5 ns
tCH Command Hold Time 0.8 0.8 ns
tAS Address and Bank Select Set-up Time 1.5 1.5 ns
tAH Address and Bank Select Hold Time 0.8 0.8 ns
tRCD RAS to CAS Delay 18 20 ns 1
tRC Bank Cycle Time 60 67.5 ns 1
tRAS Active Command Period 42 100K 45 100K ns 1
tRP Precharge Time 18 20 ns 1
tRRD Bank to Bank Delay Time 12 15 ns 1
tCCD CAS to CAS Delay Time 1 1 CK
1. These parameters account for the number of clock cycle and depend on the operating frequency of the clock, as follows:
the number of clock cycles = specified value of timing / clock period (count fractions as a whole number).
Mode Register Set Cycle
Symbol Parameter
-6K/6KI -75B/75BI
Units
Min. Max. Min. Max.
tRSC Mode Register Set Cycle Time 12 15 ns
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
39
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Read Cycle
Symbol Parameter
-6K/6KI -75B/75BI
Units Notes
Min. Max. Min. Max.
tOH Data Out Hold Time
ns 1
2.5 2.7 ns 2, 4
tLZ Data Out to Low Impedance Time 0 0 ns
tHZ Data Out to High Impedance Time 3 6 3 7 ns 3
tDQZ DQM Data Out Disable Latency 2 2 CK
1. AC Output Load Circuit A.
2. AC Output Load Circuit B.
3. Referenced to the time at which the output achieves the open circuit condition, not to output voltage levels.
4. Data Out Hold Time with no load must meet 1.8ns (-75H, -75D, -75A).
Refresh Cycle
Symbol Parameter
-6K/6KI -75B/75BI
Units Notes
Min. Max. Min. Max.
tREF Refresh Period 64 64 ms 1
tSREX Self Refresh Exit Time 1 1 CK
1. 4096 auto refresh cycles.
Write Cycle
Symbol Parameter
-6K/6KI -75B/75BI
Units
Min. Max. Min. Max.
tDS Data In Set-up Time 1.5 1.5 ns
tDH Data In Hold Time 1 0.8 ns
tDPL Data input to Precharge 12 15 ns
tWR Write Recovery Time 12 15 ns
tDAL3 Data In to Active Delay, CAS Latency = 3 5 5 CK
tDAL2 Data In to Active Delay, CAS Latency = 2 4 4 CK
tDQW DQM Write Mask Latency 0 0 CK
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
40
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Clock Frequency and Latency
Symbol Parameter -6K/6KI -75B/75BI Units
fCK Clock Frequency 166 133 MHz
tCK Clock Cycle Time 6.0 7.5 ns
tAA CAS Latency 3 3 CK
tRP Precharge Time 3 3 CK
tRCD RAS to CAS Delay 3 3 CK
tRC Bank Cycle Time 10 9 CK
tRAS Minimum Bank Active Time 7 6 CK
tDPL Data In to Precharge 2 2 CK
tDAL Data In to Active/Refresh 5 5 CK
tRRD Bank to Bank Delay Time 2 2 CK
tCCD CAS to CAS Delay Time 1 1 CK
tWL Write Latency 0 0 CK
tDQW DQM Write Mask Latency 0 0 CK
tDQZ DQM Data Disable Latency 2 2 CK
tCSL Clock Suspend Latency 1 1 CK
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
41
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
AC Parameters for Write Timing
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
tCES
tCS
tCH
tAS
tRCD tDALtDS
Activate
Command
Bank 0
Write with
Auto Precharge
Command
Bank 0
Activate
Command
Bank 1
Write with
Auto Precharge
Command
Bank 1
Activate
Command
Bank 0
Write
Command
Bank 0
Precharge
Command
Bank 0
Activate
Command
Bank 0
tDH
Ax0 Ax3Ax2Ax1 Bx0 Bx3Bx2Bx1 Ay0 Ay3Ay2Ay1
tCK2
tCKH tCKL
Activate
Command
Bank 1
RAy
CBx CAyRAy
RBx
RBxCAx
RBy
RBy
RAz
RAz
RAx
RAx
tAH
*BA0 = ”L”
Bank2,3 = Idle
tRC
tCEH
tDPL
tRP tRRD
tDPL and tDAL depend on clock cycle time and
(Burst length = 4, CAS latency = 2)
speed sort. See the Clock Frequency and
Latency Table.
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
42
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
AC Parameters for Read Timing (3/3/3)
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13
T10
Hi-Z
A10
A0-A9,
tRCD
tRAS
Activate
Command
Bank 0
Activate
Command
Bank 1
Activate
Command
Bank 0
tCK3
Read with
Auto Precharge
Command
Bank 1
tRC
tAC3 tOH
Bx0 Bx1
CBx RAy
RBx
RBx
RAy
CAxRAx
RAx
* BA0 = ”L” Read with
Auto Precharge
Command
Bank 0
Begin Auto
Precharge
Bank 0
Bank2,3 = Idle
tRP
Bx2
Begin Auto
Precharge
Bank 1
tRRD
Ax3Ax2Ax1Ax0
(Burst length = 4, CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
43
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
AC Parameters for Read Timing (2/2/2)
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13
T10
Hi-Z
A10
tCS
tCH tCEH
tAS
tAH
tRRD
tRCD
tRAS(min)
tLZ
Activate
Command
Bank 0
Activate
Command
Bank 1
Activate
Command
Bank 0
tCES
tCK2
Read with
Auto Precharge
Command
Bank 1
tRC
tRP
tAC2 tOH
tHZ
tCKH
Bx0
Begin Auto
Precharge
Bank 1
Bx1
tHZ
CBx RAy
RBx
RBx
RAy
CAxRAx
RAx
tCKL
Ax0 Ax1
* BA0 = ”L” Read with
Auto Precharge
Command
Bank 0
Begin Auto
Precharge
Bank 0
Bank2,3 = Idle
tRP
Note: Must satisfy tRAS(min)
For -260: extend tRCD1 clock
(Burst length = 2, CAS latency = 2; tRCD, tRP = 2)
A0-A9,
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
44
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
AC Parameters for Read Timing (3/2/2)
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13
T10
Hi-Z
A10
tCS
tCH tCEH
tAS
tAH
tRCD tLZ
Activate
Command
Bank 0
Activate
Command
Bank 1
Activate
Command
Bank 0
tCK3
Read with
Auto Precharge
Command
Bank 1
tRP
tAC3 tOH
tHZ
tCKH
Bx0
Begin Auto
Precharge
Bank 1
Bx1
tHZ
CBx RAy
RBx
RBx
RAy
CAxRAx
RAx
tCKL
Ax0 Ax1
* BA0=” L” Read with
Auto Precharge
Command
Bank 0
Begin Auto
Precharge
Bank 0
Bank2,3=Idle
tRP
tCES
Note: Must satisfy tRAS(min).
Extended tRCD 1 clock.
Not required for BL 4.
tRRD tRAS tRC
(Burst length = 2, CAS latency = 3; tRCD, tRP = 2)
A0-A9,
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
45
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
AC Parameters for Read Timing (3/3/3)
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13
T10
Hi-Z
A10
A0-A9,
tRRD
tRCD
tRAS (mIn)
Activate
Command
Bank 0
Activate
Command
Bank 1
Activate
Command
Bank 0
tCK3
Read with
Auto Precharge
Command
Bank 1
tRC
tRP
tAC3 tOH
Bx0
Begin Auto
Precharge
Bank 1
Bx1
CBx RAy
RBx
RBx
RAy
CAx
RAx
RAx
Read with
Auto Precharge
Command
Bank 0
Begin Auto
Precharge
Bank 0
tRP
Ax0 Ax1
Note: Must satisfy tRAS(min).
Extended tRCD not required
for BL4.
tCEH
A11
T14
*BA0=” L”
Bank 2,3=Idle
(Burst length = 2, CAS latency = 3; tRCD, tRP = 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
46
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Mode Register Set
\
CK
CKE
CS
DQ
RAS
CAS
WE
BA0,BA1
DQM
T2 T3 T4
T0 T1 T6
T7
T8 T9T5
T11
T12 T13 T14
T10 T16
T17
T18 T19T15 T22T20
T21
Hi-Z
A10,A11
A0-A9
Precharge
Command
All Banks
Mode Register
Set Command
Any
Command
Address Key
t
RP
t
CK2
t
RSC
(CAS latency = 2)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
47
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Power-On Sequence and Auto Refresh (CBR)
\
CK
CKE
CS
DQ
RAS
CAS
WE
BS
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
Precharge
Command
All Banks
tRP
Minimum of 8 Refresh Cycles are required
1st Auto Refresh
Command
tRC
High level
is required
8th Auto Refresh
Command
Inputs must be
stable for 200µs
tCK
Any
Command
2 Clock min.
Mode Register
Address Key
Set Command
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
48
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Clock Suspension / DQM During Burst Read
\
CK
CKE
CS
DQ
RAS
CAS
WE
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9, RAx
Ax0 Ax1 Ax2 Ax3
Activate
Command
Bank 0 Clock Suspend
2 Cycles
Clock Suspend
1 Cycle
Clock Suspend
3 Cycles
RAx
Read
Command
Bank 0
CAx
tHZ
tCK3
* BA1
Ax4 Ax6 Ax7
tCES tCEH
* BA0=” L”
Bank2,3=Idle
(Burst length = 8, CAS latency = 3; tRCD = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
49
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Clock Suspension / DQM During Burst Write
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9, RAx
Activate
Command
Bank 0
RAx
CAx
DAx0
Clock Suspend
1 Cycle
DAx1 DAx2
Clock Suspend
2 Cycles Clock Suspend
3 Cycles
Write
Command
Bank 0
tCK3
DAx5 DAx6 DAx7
DAx3
* BA0=” L”
Bank2,3=Idle
(Burst length = 8, CAS latency = 3; tRCD = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
50
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Power Down Mode and Clock Suspend
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0 -A9,
tCES
tCES
VALID
CAxRAx
RAx
Ax2Ax0 Ax1 Ax3
Activate
Command
Bank 0 NOP Read
Command
Bank 0
ACTIVE
STANDBY
Clock Suspension
Start
Clock Suspension
End
Precharge
Command
Bank 0
PRECHARGE
STANDBY
tHZ
Any
Command
tCK2
tCES
tSB
NOP
* BA0=” L”
Bank2,3=Idle
tSB
(Burst length = 4, CAS latency = 2)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
51
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Auto Refresh (CBR)
\
CK
CKE
CS
DQ
RAS
CAS
WE
BS
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
Precharge
Command
Auto Refresh
Command
Auto Refresh
Command
tRC
tRP tRC
tCK2
All Banks
(CAS latency = 2)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
52
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Self Refresh (Entry and Exit)
\
CK
CKE
CS
DQ
RAS
CAS
WE
BS
DQM
T2 T3 T4
T0 T1
Hi-Z
A10
All Banks
must be idle Self Refresh
Entry
A0-A9,
Tm Tm+2 Tm+3 Tm+4 Tm+5
Tm+1 Tm+7 Tm+8 Tm+9 Tm+10Tm+6 Tm+13Tm+11 Tm+12 Tm+15Tm+14
tCES
tSB
Any Command
tCES
tRC
tSREX
Self Refresh
Exit
Power Down
Entry
Power Down
Exit
(Note: The CK signal must be reestablished prior to CKE returning high.)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
53
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Random Row Read (Interleaving Banks) with Precharge
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9, CBy
Read
Command
Bank 1
By0
tCK3
High
tAC3
Activate
Command
Bank 1
RBx
RBx
Activate
Command
Bank 0
RAx
RAx
CBx
Read
Command
Bank 1
Activate
Command
Bank 1
RBy
RBy
tRCD
Precharge
Command
Bank 1
CAx
Read
Command
Bank 0
Bx0 Bx1 Bx2 Bx3 Bx4 Bx5 Bx6 Ax0 Ax1 Ax4 Ax5 Ax6 Ax7
Precharge
Command
Bank 0
* BA0=” L”
Bank2,3=Idle
(Burst length = 8, CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
54
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Random Row Read (Interleaving Banks) with Auto-Precharge
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9, CBy
By0
tCK3
High
tAC3
Activate
Command
Bank 1
RBx
RBx
Activate
Command
Bank 0
RAx
RAx
CBx
Activate
Command
Bank 1
RBy
RBy
tRCD
CAx
Bx0 Bx1 Bx2 Bx3 Bx4 Bx5 Bx6 Bx7 Ax0 Ax4 Ax5 Ax6
Read with
Auto Precharge
Command
Bank 1
Ax1
Start Auto Precharge
Bank 1
Read with
Auto Precharge
Command
Bank 0
Start Auto Precharge
Bank 0
Read with
Auto Precharge
Command
Bank 1
* BA0=” L”
Bank2,3=Idle
RAx
RAx
Ax7
(Burst length = 8,
CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
55
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Random Row Write (Interleaving Banks) with Auto-Precharge
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
tCK3
High
DAx0 DAx1 DAx4 DAx7DAx6DAx5 DBx0 DBx3DBx2DBx1 DBx4 DBx5 DAy2
DAy1DAy0
CAX
Activate
Command
Bank 0
RAx
RAx
Activate
Command
Bank 1
RBx
RBx
Activate
Command
Bank 0
RAy
RAy
CBx CAy
tRCD
DBx7DBx6
Write with
Auto Precharge
Command
Bank 0
Write with
Auto Precharge
Command
Bank 1
Write with
Auto Precharge
Command
Bank 0
* BA0=” L”
Bank2,3=Idle
tDALtDAL
Number of clocks depends on clock cycle time and speed sort.
See the Clock Frequency and Latency table.
Bank may be reactivated at the completion of tDAL.
(Burst length = 8, CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
56
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Random Row Write (Interleaving Banks) with Precharge
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22
T20
T21
Hi-Z
A10
A0-A9,
tCK3
High
DAx0 DAx1 DAx4 DAx7DAx6DAx5 DBx0 DBx3DBx2DBx1 DBx4 DBx5 DAy2
DAy1DAy0
Write
Command
Bank 0
CAX
Activate
Command
Bank 0
RAx
RAx
Activate
Command
Bank 1
RBx
RBx
Activate
Command
Bank 0
RAy
RAy
CBx
Write
Command
Bank 1
Precharge
Command
Bank 0
Write
Command
Bank 0
CAy
Precharge
Command
Bank 1
t
RP
t
RCD
DBx7DBx6
*
BA0=” L
Bank2,3=Idle
(Burst length = 8,CAS latency = 3; tRCD, tRP = 3)
tDPL
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
57
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Read / Write Cycle
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
tCK3
Write
Command
Bank 0
CAy
DAy0 DAy1 DAy3Ax0 Ax1 Ax3Ax2
The Write Data
is Masked with a
Zero Clock
Latency
The Read Data
is Masked with a
Two Clock
Latency
Activate
Command
Bank0
RAx
RAx
CAx
Read
Command
Bank 0
DAy4
Precharge
Command
Bank 0
* BA0=” L”
Bank2,3=Idle
(Burst length = 8, CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
58
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Interleaved Column Read Cycle
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
tCK3
tRCD tAC3
CBy
Read
Command
Bank 1
CBz
Read
Command
Bank 1
CAy
Precharge
Command
Bank 1
Ax0 Ax3Ax2Ax1 Bx0 By1By0Bx1 Bz0 Bz1 Ay0 Ay3Ay2Ay1
Activate
Command
Bank 0
RAx
RAx
CBx
Read
Command
Bank 1
CAx
Activate
Command
Bank 1
Read
Command
Bank 0
RBx
RBx
Read with
Auto Precharge
Command
Bank 0
Start Auto Precharge
Bank 0
* BA0=” L”
Bank2,3=Idle
(Burst length = 4, CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
59
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Auto Precharge after Read Burst
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
tCK3
High
Read with
Auto Precharge
Command
Bank 1
CBy
Start Auto Precharge
Bank 1
Start Auto Precharge
Bank 0
Ax3Ax2Ax0 Ax1 Bx3Bx2Bx0 Bx1 Ay3Ay2Ay0 Ay1
Activate
Command
Bank 0
RAx
RAx
Read with
Auto Precharge
Command
Bank 1
CBx
Read with
Auto Precharge
Command
Bank 0
Activate
Command
Bank 1
RBx
CAx RBx
Activate
Command
Bank 1
Read
Command
Bank 0
RBy
CAy RBy
By0 By1
* BA0=” L”
Bank2,3=Idle
Start
Bank 1
Auto Precharge
(Burst length = 4, CAS latency = 3; tRCD, tRP = 3)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
60
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Auto Precharge after Write Burst
\
CK
CKE
CS
DQ
RAS
CAS
WE
* BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9,
tCK2
High
Write with
Auto Precharge
Command
Bank 1
CBy
Activate
Command
Bank 1
RBx
RBx
Write with
Auto Precharge
Command
Bank 1
CBx
DAx3DAx2DAx1DAx0 DBx3DBx2DBx1DBx0 DAy3DAy2DAy1DAy0 DBy3DBy2DBy1DBy0 DAz3DAz2DAz1DAz0
Activate
Command
Bank 0
RAz
RAz
Write
Command
Bank 0
CAx
Write with
Auto Precharge
Command
Bank 0
CAy
Activate
Command
Bank 1
RBy
RBy
Activate
Command
Bank 0
RAx
RAx
Write with
Auto Precharge
Command
Bank 0
CAz
* BA0=” L”
Bank2,3=Idle
A11
tDALtDAL
Number of clocks depends on clock cycle and speed sort.
See the Clock Frequency and Latency table.
Bank may be reactivated at the completion of tDAL.
tDAL
(Burst length = 4, CAS latency = 2)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
61
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Burst Read and Single Write Operation
\
CK
CKE
CS
DQ0 - DQ7
RAS
CAS
WE
* BA1
LDQM
A10
A0-A9,
DQ8 - DQ15
UDQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
tCK2
Activate
Command
Bank 0
RAv
RAv
CAv
Read
Command
Bank 0
Single Write
Command
Bank 0
CAw
High
CAy
Read
Command
Bank 0
Av0 DAw0
Hi-Z
Av2Av1
Av3 DAx0
Av2Av1 Ay2
DAw0 Ay0 Ay3Av0
Av3
Single Write
Command
Bank 0
Ay3
Single Write
Command
Bank 0
DAz0
DAz0
CAx CAz
Lower Byte
is masked
Ay0 Ay1
Upper Byte
is masked
Lower Byte
is masked
* BA0=” L”
Bank2,3=Idle
(Burst length = 4, CAS latency = 2)
A11
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
62
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
CS Function (Only CS signal needs to be asserted at minimum rate)
\
CK
CKE
CS
DQ
RAS
CAS
WE
BA0,BA1
DQM
T2 T3 T4
T0 T1 T6 T7 T8 T9T5 T11 T12 T13 T14
T10 T16 T17 T18 T19T15 T22T20 T21
Hi-Z
A10
A0-A9, A11
tCK3
RAx
Low
RAx CAx CAy
Read
Command
Bank A
Write
Command
Bank A
Activate
Command
Bank A
Precharge
Command
Bank A
Ax0 DAy0 DAy3DAy2DAy1Ax3Ax2Ax1
tRCD tDPL
(at 100MHz Burst Length = 4,CAS Latency = 3, tRCD, tRP = 3)
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
63
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Package Dimensions (400mil; 54 lead; Thin Small Outline Package)
Lead #1
0.80 Basic 0.35
10.16 ± 0.13
22.22 ± 0.13
11.76 ± 0.20
- 0.05
+ 0.10
0.71REF
Detail A
0.10
Seating Plane
Detail A
0.5 ± 0.1
0.05 Min
1.20 Max
0.25 Basic Gage Plane
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
64
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Revision Log
Rev Date Modification
1.0 Sep 2006 Official Release
1.1 Jan 2007 Add Waveforms
1.2 Oct 2007 Add ICC data max description
1.3 Sep 2008 Add burst stop command in State Truth Table
Support industrial temperature scope
1.4 Aug 2009 Removed CL2 information.
NT5SV8M16FS / NT5SV8M16FT
128Mb Synchronous DRAM
REV 1.4
08/2009
65
© NANYA TECHNOLOGY CORPORATION
NANYA reserves the right to change products and specifications without notice.
Nanya Technology Corporation.
All rights reserved.
Printed in Taiwan, R.O.C.
The following are trademarks of NANYA TECHNOLOGY CORPORATION in R.O.C, or other countries, or both.
NANYA NANYA logo
Other company, product and service names may be trademarks or service marks of others.
NANYA TECHNOLOGY CORPORATION (NTC) reserves the right to make changes without notice. NTC warrants performance
of its semiconductor products and related software to the specifications applicable at the time of sale in accordance with NTC’s
standard warranty. Testing and other quality control techniques are utilize to the extent NTC deems necessary to support this
warranty. Specific testing of all parameters of each device is not necessarily performed, except those mandated by government
requirements.
Certain applications using semiconductor products may involve potential risks of death, personal injury, or severe property or
environmental damage (“Critical Applications”).
NTC SEMICONDUCTOR PRODUCTS ARE NOT DESIGNED, INTEND, AUTHORIZED, OR WARRANTED TO BE SUITABLE
FOR USE IN LIFE-SUPPORT APPLICATIONS, DEVICES OR SYSTEMS OR OTHER CRITICAL APPLICATIONS.
Inclusion of NTC products in such applications is understood to be fully at the risk of the customer. Use of NTC products in such
applications requires the written approval of an appropriate NTC officer. Question concerning potential risk applications should
be directed to NTC through a local sales office.
In order to minimize risks associated with the customer’s applications, adequate design and operating safeguards should be
provided by customer to minimize the inherent or procedural hazards.
NTC assumes no liability of applications assistance, customer product design, software performance, or infringement of patents
or services described herein. Nor does NTC warrant or represent that any license, either express or implied, is granted under
any patent right, copyright, mask work right, or other intellectual property right of NTC covering or relating to any combination,
machine, or process in which such semiconductor products or services might be or are used.
NANYA TECHNOLOGY CORPORATION
HWA YA Technology Park
669, FU HSING 3rd Rd., Kueishan,
Taoyuan, Taiwan, R.O.C.
The NANYA TECHNOLOGY CORPORATION home page can be found at
http:\\www.nanya.com
®